Loading...
HomeMy WebLinkAboutSentry Const 2655 Davos Tr Blower Door Test Report 8-16-2018.pdf U BUILDING LEAKAGE TEST ' $aving Energy is Easy with Frostbusters & Coolth! INV% Frostbusters & Coolth Co. PO Box 94 I Basalt, CO 81621 zw Ari71if #I%L � Email: fritzd@frostbusters.com Website: www.frostbusters.com Date of Test: 8/16/2018 Test File: Sentry Const 2655 Davos Tr Blower Door Test 8-16-2018 Customer: Sentry Construction, Inc. Technician: Fritz Diether PO Box 480 Project Number: Edwards, CO 81632 Phone: 970-376-2020 Building Address: East Side of Duplex Email: mikeyoung2020@mac.com 2655 Davos Trail Vail, CO 81657 Test Results Per the 2015 IECC: The building or 1. Airflow at 50 Pascals: 1497 CFM50 (50 Pa = 0.2 w.c.) 2.97 ACH50 dwelling unit shall be tested and verified as having an air leakage 2. Leakage Area: 82.3 in2 LBL ELA @ 4 Pa rate not exceeding three air changes per hour (3 ACH50) when 3. Building Leakage Curve: Flow Coefficient(C) = 117.7 tested with a Blower Door at a Exponent(n) = 0.650 (Assumed) pressure of 50 pascals (pa) in Climate Zones 3 through 8. (Eagle 4. Test Settings: Test Standard: RESNET One-Point Test County is Climate Zone 6) Building Test Mode: Depressurization Passes at 2.97 ACH50. 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 97.3 CFM 0.19 ACH 24.3 CFM per person 2. Estimated Design Infiltration Rate: Winter: 157.1 CFM Summer: 90.4 CFM 0.31 ACH 0.18 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 4 g�' BUILDING LEAKAGE TEST Page 2 of 4 (or)i Date of Test: 8/16/2018 Test File: Sentry Const 2655 Davos Tr Blower Door Test 8-16-2018 Building Information Location Climate Information Volume 30219 Ventilation Weather Factor 0.80 Surface Area Energy Climate Factor 19.00 Floor Area 2393 Heating Degree Days 9000 Height 38 Cooling Degree Days 28 #of Bedrooms 3 Design Winter Wind Speed 1.6 mph #of Occupants 4 Design Summer Wind Speed 10.9 mph Year of Construction 2018 Design Winter Temp Diff 77 deg F Wind Shield S Design Summer Temp Diff 11 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 ` r]LtiE Date of Test: 8/16/2018 Test File: Sentry Const 2655 Davos Tr Blower Door Test 8-16-2018 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 78.0 75.0 8000.0 Baseline Pressure Data Baseline 1 (Pa) .8 Baseline 2 1.1 Baseline 3 .1 Baseline 4 1.0 Baseline 5 1.0 Average Baseline(Pa) 0.8 Baseline Range(Pa) 1.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) Configuration -50.0 -50.8 64.0 1444 1512 Ring A Time Averaging Period: 10 Deviations from Standard RESNET One-Point Test -Test Parameters None