Loading...
HomeMy WebLinkAboutF18-0072_Approved Documents_1543256784.pdf 75 South Frontage Road Fire -Construction Permit West, TOWN OF VAIL F18-0072 Vail, CO 81657 Issued: 11/26/2018 TOWN of VAILOFOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 332 MILL CREEKCIR(210108249008)(210108249008) Unit#: ParcelNumber: 210108249008 Subdivision:VAIL VILLAGE FILING 1 Block: 1 Lot: 11, Subdivision:VAIL VILLAGE FILING 1 Block: 1 Lot: LegalDescription: 10 PARTOF BK-0256 PG-0248 QCD 05-10-77 BK-0275 PG-0901WD 09-26-78 BK-0284 PG-0760 QCD 03-15-79 BK-0284 PG-0761 QCD 03-15-79 BK-0284 PG-0762 WD 03-25-79 R873855 SWD 04- 09-04 R878657 SWD 04-09-04 R878659 SWD 04-14-04 Contacts ContactType: Applicant Full Name: Steve Allen Address: 274 CenterDrive Glenwood Springs,CO 81601 Phone: 7202190574 ContactType: PropertyOwner Full Name: TRIPLE THREATNLC LLC Address: Phone: None Contractor Contractor Type: Fire Protection Company: WesternStates Fire ProtectionCo. State License#: Phone: 303-549-8975 Projectlnformation ProjectName: Triple ThreatNLC LLC 2017 ProjectDescription: Install Fire Sprinklerper NFPA 13D and Vail Fire Requirements Fees Paid Account#:001-0000.31111.00-Fire SuppressionPermitFee Fee Amount: $1,493.28 Account#:001-0000.31123.00 Fire SuppressionReviewFee Fee Amount: $432.00 TotalPaid: $1,925.28 Conditions Issued By: Town ofVailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicantagrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law. Failure to do so will void this Permitand the applicantshall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # F 18-0072 Date Printed: 10/11/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0072 Status: Created Permit Number: Date Started: 10/05/2018 Permit Type: Fire-Construction Permit Subc ases Fire Suppression Lot Number: 11 Property: 332 MILL CR EEK CIR (210108249008)(210108249008) Contacts Contact Type: Applicant Company Name: Western States Fire Protection Full Name: Steve Allen Address: 274 Center Drive Glenwood Springs,CO 81601 Email: steve.allen@wsfp.us Contact Type: Property Owner Full Name: TR IPLE THR EAT NLC LLC Address: Permit Fees Fee Information Account Amount Fire Suppression Permit Fee 001-0000.31111.00 $1,493.28 Fire Suppression Review Fee 001-0000.31123.00 $432.00 Payment Information Date Paid Payment Type Amount Fire Suppression Permit Fee 10/11/2018 Credit Card $1,493.28 Paid By: -Notes:visa-robert merlino Fire Suppression Review Fee 10/11/2018 Credit Card $432.00 Paid By: -Notes:visa-robert merlino FEE TOTAL $1,925.28 AMOUNT PAID $1,925.28 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 10/11/2018-2:03:55 PM-Generated by:cgodfrey 1/ 1 FIRE PROTECTION HYDRAULIC CALCULATIONS AND MATERIAL CUT SHEETS FROM: 1110 Western States Fire Protection Co. plarecrief „demo, aid plofteizte, 274 CENTER DRIVE GLENWOOD SPRINGS, CO 81601 (720)219-0574 FOR: PRIVATE RESIDENCE 332 MILL CREEK CIRCLE VAIL, CO. 81657 JOB# CH0381 SUBMITTED BY: STEVE ALLEN PROJECT MANAGER OCTOBER 4, 2018 C ff0m Western states Fire Protection Co. pplotedig9 4âie4 awe proem Flow Test Information Done By: Steve Allen Address: 33Z Hydrant Location: Same Date & Time: ( '27- i ' @ ;vD terabli Static: (ZD p.s.i. lZD - 71471 Residual: /s? p.s.i. @ /$ZO g.p.m. 1/21141 — lZl7—fiet-w Observers; Signature Print Company Bulletin 006 Rev.K February 2017 Reliable Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Product Features • cULus Listed as Residential Sprinklers -�" .— • Push-On cover plate installation • Low water flow requirements 5, Product Description Model RFC30 Model RFC43 Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in r accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- • cordance with UL 1626. 11111 114 Model RFC30, RFC43,and RFC49 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC49 Model RFC58 Model RFC58 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link op- erating element. Sprinklers with a 165°F (74°C)temperature rating are ordinary temperature classification and should be used with a 135°F (57°C)temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and should be used with a 165°F (74°C)temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC43,and RFC49 sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 sprinklers allow 3/4"(19 mm) of cover plate adjustment. Model RFC cover plates are available in a variety of finishes Solid Perforated as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or Model RFC Cover Plate perforated cover plates. Table A Nominal K-Factor Max.Coverage Area Sprinkler Sprinkler Model gpm/psii2(I/min/bat-1'2) ft x ft(m x m) Identification Number(SIN) RFC30 3.0(43.2) 14 x 14 (4.3 x 4.3) RA0611 RFC43 4.3(62) 20 x 20(6.1 x 6.1) RA0612 RFC49 4.9(70.6) 20 x 20(6.1 x 6.1) RA0616 RFC58 5.8(84) 20 x 20(6.1 x 6.1) RA0613 www.reliablesprinkler.com Model RFC30 Residential Sprinkler SIN RA0611 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NPT or ISO 7-1 R1/2 Nominal K-Factor:3.0(43.2 metric) Sensitivity , _ Max.Working Pressure: 175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) Temperature Rating Material Specifications 165°F (74°C)sprinkler �J Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate Sealing Assembly:Nickel Alloy with PTFE ` - Load Screw:Bronze Alloy Sprinkler Wrench - Towers:Copper Alloy Model FC Pins:Stainless Steel `s Deflector:Bronze Alloy Listings and Approvals Bottom View l.9r Cup:Steel cULus Listed Model RFC30 Sprinkler Corn ponentsand Dimensions Figure 1 2-5/16"(58 mm) Threads Dia. Body Cup ~�__ _ f _ �_ Tower ' = 1-3/4"(44 mm)+/-1/4"(6 mm) -�` Fusible Link .�. Nominal face of fitting to ceiling °�1_ 4:-..! •�• Deflector(retracted) II-- --1 3/16" 5 mm ) Pin(extended) - Deflector(extended) ;; 1 1 Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC30 Sprinkler Hydraulic Design Criteria Table B Minim urn Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Wm in) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1) the flow listed in Table B above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev. K ��';��'� Page 2 of 7 February 2017 www.reliablesprinkler.com Model RFC43 Residential Sprinkler SIN RA0612 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) , '11111k Threads:1/2"NPT or ISO 7-1 R1/2 Nominal K-Factor:4.3(62 metric) Sensitivity Nk Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) . r Temperature Rating Material Specifications 165°F (74°C)sprinkler 4/#1i Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate oil Yoke:Brass Alloy Model RFC cover plate Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Sprinkler Wrench t Towers:Copper Alloy Model FC Pins:Stainless Steep ''.'• Deflector:Bronze Alloy Listings and Approvals Bottom View f 6t Cup:Steel cULus Listed Model RFC43 Sprinkler Com ponentsand Dimensions Figure 2 2-5/16"(58 mm) Threads Dia. Body Cup — = S t .W_4.1 Tower 1-3/4"(44 mm)+/-1/4"(6 mm) � Fusible Link Nominal face of fitting to ceiling-irAil �� ��� Deflector(retracted) `ate' '`ate' 3/16" 5 mm ) ----- 77x7//, Pin(extended) I I I I Ji Deflector(extended) ; .rtr„-, Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC43 Sprinkler Hydraulic Design Criteria Table C Minim urn Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Wm in) (bar) 12 x 12 12 7.8 (3.6 x 3.6) (45) (0.54) 14 x 14 13 9.1 (4.3 x 4.3) (49) (0.63) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1) the flow listed in Table C above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev. K ��';��'� Page 3 of 7 February 2017 www.reliablesprinkler.com Model RFC49 Residential Sprinkler SIN RA0616 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NPT or ISO 7-1 R1/2 — Nom inal K-Factor:4.9(70.6 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) .;._L Tr,,i9-. Temperature Rating Material Specifications 165°F (74°C)sprinkler — .si( Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate 11 Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate Sealing Assembly:Nickel Alloy with PTFE _ Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC ' Pins:Stainless Steel , ,1-.1 c , and Approvals �'"s Bottom View 4, l'fy� �;� 1' Deflector:Bronze Alloy Listings Cup:Steel cULus Listed Model RFC49 Sprinkler Corn ponentsand Dimensions Figure 3 -2-5/16'(58 mm) Threads Dia. Body Cup �' � = f � _ =m,I Tower r 1-3/4"(44 mm)+/-1/4"(6 mm) Fusible Link ��� Nominal face of fitting to ceiling iii l!: 41:".. �' Deflector(retracted) r.00 -661,11 \\\\\\\ 111 v—'+ 1/////// r 3/16"(5 mm) i „„, Pin(extended) I ' ► Deflector(extended) 11j Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC49 Sprinkler Hydraulic Design Criteria Table D Minim urn Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Wm in) (bar) 16 x 16 25.6 GPM for .1 density 7.0 (4.9 x 4.9) (0.48) 18 x 18 17 12.0 (5.5 x 5.5) (64.3) (0.83) 20 x 20 20 16.7 (6.1 x 6.1) (75.7) (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1) the flow listed in Table D above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev. K ��';��'� Page 4 of 7 February 2017 www.reliablesprinkler.com Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Sensitivity Style:Flat Concealed Pendent Fast-response Threads:1/2"NPT or ISO 7-1 R1/2 ... Nominal K-Factor:5.8(84 metric) Temperature Ratings Max.Working Pressure:175 psi(12 bar) Ordinary: -*- Min. Min.Spacing:8 ft.(2.4 m) 165°F (74°C)sprinkler , '',l'o it 135°F (57°C)cover plate Material Specifications Intermediate: 1 1, a i/� Therm alSensor:Nickel Alloy Solder Link 212°F (100°C)sprinkler Sprinkler Body:Brass Alloy 165°F (74°C)cover plateL • Levers:Bronze Alloy _.. Yoke:Brass Alloy Cover Plate `` . z� R Sealing Assembly:Nickel Alloy with PTFE Model RFC Cover Plate Load Screw:Bronze Alloy -- Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model FC Deflector:Chrome Plated Bronze Alloy / �'� Cup:Steel Listings and Approvals Bottom View; . ,e cULus Listed , ! Cover Plate Finishes (See Table H) Model RFC58 Sprinkler Corn ponentsand Dimensions Figure 4 2-5/16"(58 mm) Dia. Threads Body Cup 1W.I'M =WE=� Tower — ? , Fusible Link 1-7/8"(48 mm)+1-3/8"(9 mm) ,Nominal face of fitting to ceiling IIiI1 Deflector(retracted) r`—r , —r _ \\\\\\\ I _ _ 1 iiiiiii x 3/16"(5 mm) Pin(extended) – Il i �1 Deflector(extended) � 'i' Fi Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minim urn Flow and Residual Pressure Max.Coverage Area'2) Flow Pressure ft.x ft. gpm psi (m x m) (Wm in) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1) the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev. K ��';��'� Page 5 of 7 February 2017 www.reliablesprinkler.com Cover Plate Finishesil) Table H Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Custom Color Clad(3) Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss,unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant.Stainless steel clad cover plates are not available perforated. Installation Dimensions TableJ Recommended Min.to Min.to Max. Cover Plate Cover Plate Max. Face Dropped Deflector Cover Hole Diameter Cover Plate Sprinkler Diameter Adjustment of Fitting to Distance below Model Plate inch in Ceiling inch Ceiling1') Ceiling Temperature Model (mm) (mm) (mm) inch inch Rating (mm) (mm) RFC30 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC43 RFC (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC49 135°F2 RFC58 RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A 1/2"x 1/2" brass nipple extension(Reliable P/N 6999991900)is available where necessary for replacement of existing sprinklers. 2. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 3. For use with 212°F(100°C)temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F(66°C). Inst.Ilatu®�n Model RFC series sprinklers are intended to be installed in ac- Donot exceed the maximum recommended torque. Exceeding cordance with NFPA 13, NFPA 13R, or NFPA 13D,as well as the the maximum recommended torque may cause leakage or im- requirements of applicable authorities having jurisdiction. Mod- pairment of the sprinkler. Use care when inserting or removing el RFC series sprinklers must not be installed in ceilings with the wrench from the sprinkler to avoid damage to the sprinkler. positive pressure in the space above.Ensure that the 4 slots in the cup are open and unobstructed following installation. Model Install the cover plate by hand by pushing the cover plate into RFC series sprinklers are shipped with a protective cap that the cup and turning the cover in the clockwise direction until it should remain on the sprinkler until installed.The protective cap is tight against the ceiling. should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. AN'I u Model RFC series sprinklers are installed with the Model FC Model RFC series sprinklers are intended for installation where wrench.The use of any other wrench to installed Model RFC se- residential sprinklers are permitted or required by NFPA 13, ries sprinklers is not permitted and may damage the sprinkler. NFPA 13R, and NFPA 13D.The sprinklers are concealed pen- Temporarily remove the protective cap during installation of the dent residential sprinklers. sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body.Do not wrench any other part of the Model RFC 30, RFC43, and RFC49 sprinklers are available in sprinkler/cup assembly.The Model FC wrench is designed to ordinary temperature classification for installation where the be turned with a standard 1/2" square drive.Tighten the sprin- Maximum Ceiling Temperature does not exceed 100°F (38°C). kler into the fitting after applying a PTFE based thread sealant Model RFC58 sprinklers are available in either ordinary or in- to the sprinkler's threads. Recommended installation torque is 8 termediate temperature classification for installation where the to 18 ft/lb(11 to 24 N/m). Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Bulletin 006 Rev. K Page 6 of 7 February 2017 www.reliablesprinkler.com Wrench Model FC Maintenance Guarantee Model RFC series sprinklers should be inspected and the For the Reliable Automatic Sprinkler Co.,Inc. guarantee,terms, sprinkler system maintained in accordance with NFPA 25. Do and conditions,visit www.reliablesprinkler.com. not clean sprinklers with soap and water,ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace Patents any sprinkler cover plate assembly which has been painted (other than factory applied)or damaged in any way. A stock of Model RFC30,RFC43,RFC49,and RFC58 sprinklers are spare sprinklers should be maintained to allow quick replace- covered by U.S.Patent No. 9,248,327 and U.S.Patent No. ment of damaged or operated sprinklers. Prior to installation, 7,275,603. sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to Model RFC30 and RFC43 sprinklers are additionally covered sprinklers that would cause improper operation or non-oper- by U.S.Patent No. 8,776,903. ation. Ordering Information Listings and Approvals Specify the following when ordering. Listed by Underwriters Laboratories, Inc. and UL Certified for Sprinkler Canada(cULus) • Model (RFC30,RFC43,RFC49,RFC58) UL • Temperature Rating Listing Category Cover Plate • ModelRFC • Temperature Automatic Sprinkler Rating UL Guide Number • Finish(See Table H) Sprinkler Wrench • Model FC VK KW z CD CO CO COO N Bulletin 006 Rev. K �e1i��1e Page 7 of 7 February 2017 www.reliablesprinkler.com Bulletin 135 R ev.M ® ModeIF1 'tenable Residential Sprinklers for 5 DesignDensity of.05 gpmfft2 a Model Fl Res Sprinklers engineered forthelowestflows EXPOSED to meettheminimumdesigndensityof.05 gpmfft2 HEADS Types: 1. F1 Res 30 Pendent • . 2. F1 Res 30 Recessed Pendent/F2 • - 3. F1 Res 30 Recessed Pendent/FP r r 4. F1 Res 49 Pendent _ _. 5. Fl Res 49 Recessed Pendent/F1 s 6. Fl Res 49 Recessed Pendent/FP F� 7. Fl Res 58 Pendent Fl R es30,49,58&76 Fl Res 30,49, 58&76 8. Fl Res 58 Recessed Pendent/F1 Recessed Pendent/Fl Recessed Pendent/FP F1 Res 58 HSWX 9. Fl Res 58 Recessed Pendent/FP 10. F1 Res 76 Pendent 11. F1 Res 76 Recessed Pendent/F1 12. F1 Res 76 Recessed Pendent/FP 13. Fl Res 30 CCP Pendent ' 14. Fl Res 49 CCP Pendent 15. Fl Res 58 CCP Pendent 411Dlkof 16. Fl Res 76 CCP Pendent 17. F1 Res 44 HSW F1 R es30,49,58&76 F1 Res 44&58 F1 R es44 SWC 18. Fl Res 44 Recessed HSW/F2 CCP Pendent Recessed HSW/F2 19. F1 Res 58 HSW 20. Fl Res 58 HSWX Horizontal Sidewall sprinklers(Figs. 5,6&7)are equally attrac- 21. KRes58 HSWX tivewhenaboveceiling piping cannotbe used. 22. Fl Res 58 HSW Recessed HSW/F2 The3mmglass-bulb pendentsprinklers permittheefficient use 23. Fl Res 44 SWC of residential watersupplies for sprinkler coverage in residential Listings & Approvals fire protection design. The lowflowFl R essprinklers arespecially engineered forfast 1. Listed by Underwriters Laboratories Inc.and thermal response to meet the sensitive fire protection applica- UL Certified for Canada (cULus) tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heatcauses a sprinkler's Sprinklers for .10 Density: Refer to Bulletin 176 heat-sensitive element,glassbulborlinktoactuate,releasing the UL Listing Category waterway forwaterflowontothedeflector,evenlydistributing the R esidential Automatic Sprinkler discharged waterto control afire. UL Guide Number Technical Data: VKKW • Thermal Sensor: Soldered Element (Link)or Nominal 3mm glass-bulb Patents • Sprinkler Frame : Brass Casting US Patent No. 6,516,893 applies to the Model F1 R es49 • Sprinklers' Pressure R ating: 175 psi &58 Pendent Sprinklers Factory Hydrostatically Tested to 500 psi US Patent No. 7,353,882 applies to Model Fl R es44&58 • Thread Size: 1/2" NPT(R'/2) HSW Sprinklers • K-Factor: 3.0(43.2XActual)-Fl R es30 Pendent Sprinkler US Patent No. 7,784,555 applies to Model Fl R es44 SWC 4.9(70.6XActual) Fl R es49 Pendent Sprinkler Sprinklers 5.8(83.5XActual)-Fl R es58 Pendent&HSWSprinkler Product Description 7.6(109)(Actual)-Fl R es76 Pendent Sprinkler . Model F1 Res Pendent sprinklers (Figs. 1, 2, 3, &4)are fast 4.4(63)(Actual)-Fl R es44HSWSprinkler response sprinklers combining excellent durability,highsensitiv- • Density: Minimum 0.05 gpm/ft2 ity glass-bulb and low profile decorative design. The F1 R es Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model Fl R esSprinklers are used for Residential Fire Pro- the onlyrecessed escutcheonsto be used with Model F1 R es tection according to UL 1626 Standard*. For ceiling types: sprinklers. Use of anyotherrecessed escutcheonwillvoid all Smooth FlatHorizontal,or beamed,or sloped, in accordance approvals and warranties. For installing Model F1 R esPen- with NFPA13D, 13R ,or 13 2013 editions. Be sure thatorif ice dent sprinklers use only the Model D sprinkler Wrench; for size,temperature rating,deflectorstyleand sprinklertypeare installing Models F1 Res Recessed Pendent, CCP & SWC in accordance with the latestpublished standards of The Na- sprinklers use only the Model GFR2 sprinkler wrench; for in- tional Fire Protection Association or the approving authority stalling Model Fl Res Recessed HSW sprinklers use onlythe having jurisdiction. Model GFR 2Sprinkler Wrench. Use of wrenches other than Installation those specified may damage these sprinklers. Install F1 R es Models Fl R es sprinklers are to be installed as shown. 44 with a ceiling to deflector distance of 4" 12". Flow arrow Model Fl, F2 and FP Escutcheons, illustrated herewith, are on deflector must point away from near wall and"Top" mark- ing must face ceiling. Escutcheon*, Fl or F2, Data: Adjustment "A" Face of fitting to ceiling Type Inch(mm) Inch(mm) Inch(mm) Deflector Distance below bottom of beam Inch(mm) F1 3/,(19.0) Min.Recessed=15/8(41.3) 3/8(9.5) 13/4(44.4) Max.Recessed=7/8(22.2) 11/8(28.6) 1 (25.4) F2 /2(12.7) Min.Recessed=15/8(41.3) 3/8(9.5) 13/4(44.4) Max.Recessed=11/8(28.6) 7/3(22.2) 11/4(31.7) *Note:Escutcheons F1 or F2 may be used with Model F1 R es49,58&76 R ecessedPendent Sprinkler • Model Fl Res 30 Recessed Pendent/F2 • Model Fl Res 30, 49, 58 &76 Pendent • Model Fl Res 49, 58 &76 Recessed Pendent/Fl AI.‘ • 1, _..: �1 Fl escutcheon, 3/4" (19mm) adjustment �— 2 1/4""HOLE DIA. __ [57.2mm] 1 15/16"DIA. [49.2mm] \ / I rt I""X 1/2"REDUCER I1J / TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER FACE OF FITTING TO WRENCH BOSS. r —I, 1 CEILING DIMENSION.. �__� 3/8"-1 1/8"(F1 ESCUTCHEON) 1111 ®��d� �/, 1 3/8"-7/8"(F2 ESCUTCHEON) s��=•1 lig4— ADJUSTMENT lml l 1%//O "11, } III ] � -_ no [3.2mm] y y 227/32"DIA . 1.35,-;,,3135,40.28 [72.2mrq Fig. 1 Fig. 2 - . • ical Data: F1Res 30 Pendent and Recessed Pendent(SIN R3511) Thread - •u nal Orifice Max.PressureSprinkler Temp.Rating Max.Ambient Temp Actual K Sprinkler Length Size Inch • _ psi(bar) °F °C °F °C Factor Inch(mm) 1/2" NPT2764"(8.2) 155 68 100 38 3.0(43.2) 2.25(57) (R 1/2) 175 79 Ordinary Temp.Ratin• • ermediate Temp.Rating Max.Coverage area Max. Minimum 5°F/6 ° /79°C) Ft x Ft(m x m) Spacing Flow Pressure Flow ' ure Top of Intch(mm) Ceiling Spacing Ft(m) GPM(L/min) PSI(bar) GPM(L/min) PSI(bar Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0(0,48) 8(30,3) 7.0(0,48) Smoot ' '..s 11/4 to 4(31.7 to 102) using F2 e . eon. 14 x 14(4,3 x 4,3) 14(4,3) 10 (37,8) 11 (0,76) 10(37,8) 11 (0,76) Beamed Ceilings per NFP' -5 3R 8(2,4) 16 x 16 (4,9 x 4,9) 16(4,9) 13 (49) 18.8(1,3) 13(49) 18.8(1,3) or 13 installed in beams 1'/4 to 13/4(31.7 to 44.4)using F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 2. Technical Data: F1Res 49 Pendent and Recessed Pendent(SIN R3516) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Pressure Temp.Rating Ambient Temp. K Length Size Inch(mm) psi(bar) °F °C °F °C Factor Inch(mm) 1/2"NPT7/16"(11) 175 (12) 155 68 100 38 4.9(70.6) 2.25(57) (R 1/2) 175 79 150 66 Ordinary Temp.Rating Intermediate Temp.Rating I Top of Deflector Minimum Max.Coverage area Max.Spacing (155°F/68°C) (175°F/79°C) Ftx Ft(m x m) Ft(m) Flow Pressure Flow Pressure to Ceiling Spacing GPM(Umin) PSI(bar) GPM(Umin) PSI(bar) Inch(mm) Ft(m) 12 x 12 (3,6 x 3,6) 12 (3,6) 13(49) 7.0(0,48) 13 (49) 7.0(0,48) Smooth Ceilings 11/4 to 4(31.7 to 102)using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14 (4,3) 13 (49) 7.0(0,48) 13 (49) 7.0(0,48) 1 to 4(25.4 to 102)using Fl escutcheon. 16 x 16 (4,9 x 4,9) 16 (4,9) 25.6 GPM for .1 density ` 7.0(0,48) Beamed Ceilings per NFPA 8(2,4) — 13D,13R or 13 installed in 18 x 18 (5,5 x 5,5) 18 (5,5) 17 (64,3) 12 (0,83) 17 (64,3) 12(0,83) beams 11A to 13/4 (31.7 to 44.4)using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7(1,14) 20(75,7) 16,7 (1,14) to 13/4(25.4 to 44.4)using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Ordinary Temp.Rating Intermediate Temp.Rating Top of Deflector Minimum Max.Coverage area Max.Spacing (155°F/68°C) (175°F/79°C) Ftx Ft(m x m) Ft(m) Flow Pressure Flow Pressure to Ceiling Spacing GPM(Umin) PSI(bar) GPM(Umin) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 15 (57) 9.4(0,65) 15(57) 9.4(0,65) Smooth Ceilings 4 to 8(100 to 203)using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6 (0,73) 16 (60,5) 10.6(0,73) 4 to 8(100 to 203)using F1 escutcheon. 16 x 16(4,9 x 4,9) 16 (4,9) 17 (64,3) 12.0 (0,83) 17 (64,3) 12.0(0,83) Beamed Ceilings per NFPA 13D, 8(2,4) 13R or 13 installed in beams 18 x 18(5,5 x 5,5) 18 (5,5) 19 (72) 15.0(1,0) 19(72) 15.0 (1,0) 41/4 to 8(108 to 203)using F2 escutcheon,4 to 8(100 to 203) 20 x 20(6,1 x 6,1) 20(6,1) 22(83,2) 20.2(1,4) 22(83,2) 20.2(1,4) using F1 escutcheon -chnical Data: F1Res 58 Pendent and Recessed Pendent(SIN R3513) Thread '= •sinal Orifice Max. Sprinkler Max. Actual Sprinkler Pressure Temp Rating Ambient Temp. Length Size Inc ) psi(bar) °F °C °F °C K Factor Inch(mm) 1/2"NPT1/z"(13) 5 (12) 155 68 100 38 5.8(83.5) 2.25(57) (R 1/2) 175 79 150 66 Ordinary Te -ating Intermediate Temp.Rating Top of Deflector Minimum Max.Coverage area Max.Spacing (155°F/68°C) (175°F/79°C) Ftx Ft(mx m) Ft(m) Flow Pressure Flow Pressure to Ceiling Spacing GPM(Umin) PSI(bar) GPM Ir PSI(bar) Inch(mm) Ft(m) 12 x 12 (3,6 x 3,6) 12 (3,6) 16(61) 7.6(0,53) 16 (61) • 0,53) Smooth Ceilings 11/4 to 4(31.7 to 102)using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) 16 (61) 7.6(0,53) •4(25.4 to 102)using Fl escutc . 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) 16 (61) 7.6(0,53) Beamed Ceili •_ ser NFPA 13D, 8(2,4) 13R or 13 installed in .2.ms 18 x 18 (5,5 x 5,5) 18 (5,5) 19(72) 10.8(0,75) 19(72) 10.8(0,75) 11/4 to 13/4 (31.7 to 44.4)usin. F2 escutcheon, 1 to 13/4(25.4 to 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4 (1,0) 22(83,3) 14.4 (1,0) 44.4)using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 3. - , I nical Data: Fl Res 76 Pendent and Recessed Pendent(SIN R7618) Thread •mina)Orifice Max. Sprinkler Max. K Sprinkler Pressure Temp.Rating Ambient Temp Length Size Inc .1m) psi(bar) °F °C °F °C Factor Inch(mm) 3/4"NPT17/32"(13.5) 175 (12) 155 68 100 38 7.6(109) 2.25(57) (R3/4) 175 79 150 66 Ordina , -mp.Rating Intermediate Temp.Rating Max.Coverage area Max.Spacing (155°F -. (175°F/79°C) Topof Deflectorto Ceiling Minimum Ftx Ft(mx m) Ft(m) Flow Press - FIowGPM Pressure Inch(mm) Spacing GPM(L/min) PSI(bar) -v in) PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 21 (79,5) 7.6(0,53) 21 (79,5) 7.6(0,53) Smooth Ceilings 41/4 to 8(108 to 203)using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14 (4,3) 21 (79,5) 7.6(0,53) 21 (79,5) 7.6(0, _ 4 to 8(100 to 203)using F1 es eon. 16 x 16(4,9 x 4,9) 16(4,9) 21 (79,5) 7.6(0,53) 21 (79,5) 7.6(0,53) Beamed ...s per NFPA 8(2,4) 13D,13R or 13 in : -d in 18 x 18(5,5 x 5,5) 18(5,5) 21 (79,5) 7.6(0,53) 21 (79,5) 7.6(0,53) beams 41/4 to 8(108 to •- s- ing F2 escutcheon,4 to 8(100 20 x 20(6,1 x 6,1) 20(6,1) 23(87,1) 9.2(0,63) 23(87,1) 9.2(0,63) to 203)using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D • Model Fl Res 30, 49, 58 & 76 CCP Pendent* • Model Fl Res 30, 49, 58 & 76 Recessed Pendent/FP itaii) -.N.N, I .. . 6110 :,Not listed for corrosion resistance. FP push-on/thread-off escutcheon 2 5/8"[66.7mm] DIA. 2 5/8" DIA. [66.7mm] 2 5/16" DIA. HOLE IN CEILING —HOLE IN CEILING [58.7mm] CUPr---+:17.1), 2 5/16" DIA. k- __-s [58.7mm] T ------__ CUP_ 1"x1/2" REDUCER r `], CUP \ / I IT 1 I 1" X 1/2" REDUCER CEILING \ 1 II[�c•II I I Ill 1 1/4"[31.5mm] \ / 1 ';, ;,';•[. II II MAX. FACE OF FITTING TTO FACE OF CEILING L 4 } ;� iii 77 DIMENSION CEILING I I 1 1/2" [38.1mm] MAX. �� / "C' ♦ I I;I tlU IlFACE OF FITTING 'A" �A'� -„ "e» 1,,,� TO FACE OF CEILING COVER ADJUSTMENT -- ' D MENSION HEIGHT Ve 0 FP ADJUSTMENT ..Iw, 7 2'"[13mm] MAX. 9 I I 3 5/16"DIA. - I I 7 35FG04E [84.1 mm] Mo 113 Fl RES 30, 49, 58 & 76 CCP PEND. Fl RES 49 PENDENT/FP Fig. 3 Fig. 4 Note: T heF 1 R es7 6will usea 1"x%"reducer. CCP Cover Plate Data: FP Escutcheon Data: "C" ..B„ Deflector Distance below bottom "A" Deflector Distance below bottom Cover Adjustment CCP Height FP Position Inch(mm) Inch(mm) of beam Inch(mm) of beam Inch(mm) _ Inch(mm) 1/2(12.7) 15/16(24) 1 (13)-1 (25.4) Max.Recessed '/16(11) 1/2(12.7) 5/16(7.9) 3/4(19) 1/2(13) -1 (25.4) Min.Recessed 15/16(24) 1 (25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. 4. - nical Data: F1Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) •minal Max. CCP Assembly Max. Sprinkler Thread K Orihc- Pressure Temp.Rating Ambient Temp. Length Size Factor Inch(mm) psi • °F °C °F °C Inch(mm) 1/2"NPT 27/64"(8.2) 175 (12) 13 57 100 38 3.0(43.2) 2.25(57) (R 1/2) Ordinary Temp.Ra • Minimum Max.Coverage area Max.Spacing (155°F/68°C) Top of Deflectorto Ceiling Ft x Ft(m x m) Ft(m) Flow Pressure Inch(mm) Spacing GPM(Umin) PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12 (3,6) 8(30,3) 7.0(0,48) Smooth Ceilings 1/2 to 1 (13 to 25.4)usin• - 1/2 to 1 (13 to 25.4)using FP escutcheon. Beamed Ceilings per NFPA 13D,13R or 13 installed in 4) 14 x 14(4,3 x 4,3) 14 (4,3) 11 (37,8) 13.4(0,92) beams 1/2 to 1 (13 to 25.4)using CCP. 1/2 to 1 (13 to 25.4)using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D hnical Data: F1Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) CCP Thread Orific inal Max. Max. Assembly Ambient K Sprinkler Size Inch ' essure Temp. Temp. Factor Length psi : .r) Rating Inch(mm) (mm) ° °C °F °C /z"NPT 7/16"(11) 175 (12) 135 100 38 4.9(70.6) 2.25(57) (R 1/2) Max.Coverage Ordinary Te • 'ating Minimum Max.Spacing (155°F/68°C) Top of Deflector to Ceiling area Ft(m) Flow Pressure Inch(mm) Spacing Ft x Ft(m x m) GPM(L/min) PSI(bar) Ft(m) 12 x 12 (3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) Smooth Ceilings 1/2 to 13 to 25.4)using 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) CCP. Y to 1 (13 to 25.4)using FPesc ..eon. 16 x 16 (4,9 x 4,9) 16(4,9) 14(53) 8.2(0,56) Beamed Ceilings per NFPA 13D, 13R• 3 8(2,4) installed in beams Y to 1 (13 to 25.4)using 18 x 18 (5,5 x 5,5) 18(5,5) 18 (68,1) 13.5(0,93) CCP. 1/2 to 1 (13 to 25.4)using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D hnical Data: F1Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Nominal Max. CCP Assembly Max. Sprinkler Thread ; ',ice Pressure Temp. Rating Ambient Temp. K Length Size Inch(m psi(bar) °F °C °F °C Factor Inch(mm) 1/2" NPT (R 1/2) 1/2"(13) 1 2) 135 57 100 38 5.8(83.5) 2.25(57) Max.Coverage Ordinary •.Rating Minimum Max.Spacing (155°F/68° Top of Deflector to Ceiling area Ft(m) Flow Pressure Inch(mm) Spacing Ft x Ft(m x m) GPM(L/min) PSI(bar) Ft(m) 12 x 12 (3,6 x 3,6) 12(3,6) 16(61) 7.6(0,53) 14 x 14 (4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) Smooth Ceilings 1/2 to 1 (13 to 2 .• ing CCP. 1/2 to 1 (13 to 25.4)using FP escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 13D, 13R or 13 ins- ;. in beams 1/2 to 8(2,4) 1 (13 to 25.4)using CCP. 18 x 18 (5,5 x 5,5) 18(5,5) 19(72) 10.8(0,75) 1/2 to 1 (13 to 25.4)using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4 (1,0) For Ceiling types refer to NFPA 13, 13R or 13D 5. -chnical Data: F1Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Nominal Max. CCP Assembly Max. Sprinkler Thread K ti. 'ice Pressure Temp.Rating Ambient Temp. Factor Length Inch(m psi(bar) °F °C °F °C Inch(mm) 3/4"NPT17/32"(13.5) 1 ) 135 57 100 38 7.6(109) 2.25(57) (R3/4) 150 66 Max.Coverage Ordinary e • Rating Minimum Max.Spacing (155°F/68°C) Top of Deflector to Ceiling area Ft(m) Flow Pressure Inch(mm) Spacing Ft x Ft(m x m) GPM(L/min) PSI(bar) Ft(m) 1 12 x 12(3,6 x 3,6) 12 (3,6) 21 (79,5) 7.6(0,53) 14 x 14 (4,3 x 4,3) 14 (4,3) 21 (79,5) 7.6(0,53) Smooth Ceilings 1/2 to 1 (13 to 25.4 . '••CCP. 1/2 to 1 (13 to 25.4)using FP escutcheon. 16 x 16 (4,9 x 4,9) 16 (4,9) 21 (79,5) 7.6(0,53) Beamed Ceilings per NFPA 13D,13R or 13 instal-. '•beams 1/2 8(2,4) to 1 (13 to 25.4)using CCP. 18 x 18 (5,5 x 5,5) 18 (5,5) 22(83,3) 8.4(0,58) 1/2 to 1 (13 to 25.4)using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 25(94,6) 10.8(0,74) For Ceiling types refer to NFPA 13, 13R or 13D • Model F1 Res 44 &58 HSW r ' k FACE OF FITTING TO WALL DIMENSION 1 1/4"MIN. 2 1/4"HOLE DIA. [31.8mm] A [57.2mm] f7/g CEILING TO [3.2mm] DEFLECTOR 7"X 1/2"REDUCER DIMENSION f 1 .� • Model Fl Res 44 &58 Recessed HSW/F2 gi ; IRI.' /O 7 15/76""D — — I .i i.� _N_` [49.2mm] n'" I o,'/ 2 27/32""DIA. inn / , , r /,4 _. [72.2mm] 1 1 . , TURN COLLAR UNTIL i TIGHT AGAINST SPRINKLER ' ., i WRENCH BOSS. 111_...., 1/2""[13mm] \ _ 135F006—D ADJUSTMENT F1 RES 58 & 44 HSW/F2 F2 escutcheon, Fig. 5 1/2" (13mm) adjustment Technical Data: F1Res 44 HSW & HSW/F2 (SIN R3531) Escutcheon, F2, Data: Nominal Max. Sprinkler Max. Sprinkler Face of Fitting Thread Ambient K Adjustment Size Orifice Pressure Temp.Rating Temp. Factor Length Type Inch(mm) to wall Inch(mm) psi(bar) °F °C °F °C Inch(mm) Inch(mm) /z"NPT3/8"(10) 175 (12) 155 68 100 38 4.4(63) 2.45(62) F2 '/2(13) ahs-11/.6 (R 1/2) 175 79 150 66 (4.7-17.4) 6. Ordinary Temp.Rating Intermediate Temp.Rating Ma . overage area Max.Spacing (155°F/68°C) (175°F/79°C) Top of Deflector to Minimum Ft x 4 x m) Ft(m) Flow Pressure Flow Pressure Ceiling Spacing GPM(L/min) PSI(bar) GPM(L/min) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12 (3,6) 12 (45,4) 7.5(0,52) 12(45,4) 7.5(0,52) 14 x 14(4,3 x 4,3) 14 (4, 14 (53,0) 10.2 (0,71) 14(53,0) 10.2(0,71) 16 x 16(4,9 x 4,9) 16 (4,9) . 60,6) 13.3(0,92) 16(60,6) 13.3(0,92) 4 to 6(100 to 152); 1/2(13) recessed 16 x 18(4,9 x 5,5) 16 (4,9) 18 (68,1) 16.8 (1,16) 18(68,1) 16.8(1,16) using F2 escutcheon 18 x 18(5,5 x 5,5) 18 (5,5) 19 (72,0) 18.7 (1, • 19(72,0) 18.7(1,29) 16 x 20(4,9 x 6,1) 16 (4,9) 23(87,1) 27.4(1,89) 2 s ,1) 27.4(1,89) 8(2,4) 12 x 12(3,6 x 3,6) 12 (3,6) 14 (53,0) 10.2 (0,71) 14(53,0) 0.2(0,71) 14 x 14(4,3 x 4,3) 14 (4,3) 16 (60,6) 13.3(0,92) 16(60,6) 13.3(0,• o 12 (152 to 305); 16 x 16(4,9 x 4,9) 16 (4,9) 17 (64,4) 15.0 (1,04) 17 (64,4) 15.0(1,04) 1/2 recessed using F2 e - tcheon 16 x 18(4,9 x 5,5) 16 (4,9) 20(75,7) 20.7(1,43) 20(75,7) 20.7(1,43) 16 x 20(4,9 x 6,1) 16 (4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) For Ceiling types refer to NFPA 13, 13R or 13D - , nical Data: F1Res 58 HSW & HSW/F2(SIN R3533) Escutcheon, F2, Data: 1 ominal Max. Sprinkler Face of Fitting Max. Sprinkler Adjustment Thread 0 ''ce Pressure Temp.Rating Ambient K Length Type Inch mm to wall Size .si bar F °C °TF °C Factor Inch ( ) Inch(mm) ( ) (bar) ° ° ° ( ) 1/2 3/16-11/16 (R 1/2) 1/2"(13) 175(1 175 79 150 66 5.8(83.5) 2.45(62) (4.7-17.4) •rdinary Temp.Rating Intermediate Temp.Rating Max.Coverage area Max.Spacing 155°F/68°C) (175°F/79°C) Top of Deflector to Minimum Ft x Ft(m x m) Ft(m) Flo ' Pressure Flow Pressure Ceiling Spacing GPM(L/min PSI(bar) GPM(L/min) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12 (3,6) 16 (60,6) 7.: 1,53) 16(60,6) 7.6(0,53) 14 x 14(4,3 x 4,3) 14 (4,3) 18(68,2) 9.7(0,69) 18(68,2) 9.7(0,69) 4 to 6(100 to 152); 16 x 16(4,9 x 4,9) 16 (4,9) 21 (79,5) 13.2(0,91) 21 5) 13.2(0,91) 1/(13) recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16 (4,9) 25(94,7) 18.6(1,28) 25(94,7) 18.6 (1,28) 16 x 20(4,9 x 6,1) 16 (4,9) 29(109,8) 25.0(1,73) 29(109,8) 25.0 73) 8(2,4) 12 x 12(3,6 x 3,6) 12 (3,6) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 14 x 14(4,3 x 4,3) 14 (4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 6 to 1 152 to 305); 1/2(13) r-.-ssed 16 x 16(4,9 x 4,9) 16 (4,9) 26(98,4) 20.1 (1,39) 26(98,4) 20.1 (1,39) using F2 escut •-on 16 x 18(4,9 x 5,5) 16 (4,9) 31 (117,4) 28.6(1,97) 31 (117,4) 28.6(1,97) For Ceiling types refer to NFPA 13, 13R or 13D 7. • Model Fl Res 44 SWC* ,/ "Not listed for corrosion resistance. 4"to 12" A [101.60mm To 1 1/4"[31.75mm]Maximum 304.80mm] Face Of Fitting PUSH ON COVER, THEN To Wal/Dimension TURN TO ADJUST UNTIL r TIGHT AGAINST WALL. 1"X 1/2"Reducer d al Recommended 4 !le Wall Hole 2 5/76" ', ,0 i//ii. 2 5/8" [58.74mm]�� --- ja;=i„I4;• 3 5/16” Y ' !�.. [66.68mm] Dia. i Dia. `Inui ? [84.74mm] rj i TURN COLLAR UNTIL RET AGAINST SPRINKLER '^—'INKLER WRENCH BOSS. 1 21/32" [42.07mmJ 135F007 1/2"[72.70mm] Adjustment Fl RES 44 SWC Fig. 6 echnical Data: F1Res 44 SWC I SIN R3531) Cover Max. Thre.• Nominal Max. Temp. Ambient K Sprinkler Size Orifice Pressure Rating Temp. Factor Length •ch(mm) psi(bar) °F °C °F °CInch(mm) /2"NPT 3/8"(10 175 (12) 135 57 100 38 4.4(63) 2.45(62) (R'/2) Ordinary Temp.Rating Top of Deflector to Minimum Max.Coverage area Max.Spa ' g (155°F/68°C) Ft x Ft(m x m) Ft(m) Flow Pressure Ceiling Spacing • (L/min) PSI(bar) Inch(mm) Ft(m) 12 x 12 (3,6 x 3,6) 12 (3,6) 13 (A° ) 8.7(0,60) 14 x 14(4,3 x 4,3) 14 (4,3) 14 (53,0) 10.2 (0,71) 4 to 6(100 to 152); 16 x 16(4,9 x 4,9) 16 (4,9) 17 (64,3) 15.0 1) 1/2(13) recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16 (4,9) 19 (71,8) 18.7 (1,13) 16 x 20(4,9 x 6,1) 16 (4,9) 23(87,1) 27.4(1,89) 8(2,4) 12 x 12(3,6 x 3,6) 12 (3,6) 14 (52,9) 10.2 (0,71) 14 x 14(4,3 x 4,3) 14 (4,3) 15 (56,7) 11.7 (0,81) 6 to 12 (152 to 305); 1/2(13) recessed 16 x 16(4,9 x 4,9) 16 (4,9) 18 (68,1) 16.8 (1,16) using F2 escutcheon 16 x 18(4,9 x 5,5) 16 (4,9) 20(75,6) 20.7(1,43) For Ceiling types refer to NFPA 13, 13R or 13D 8. -chnical Data: F1Res 58 HSWX (SIN RA3533) Nominal Max. Sprinkler Max. Sprinkler Sprinkler Th =.d Ambient K Size Orifice Pressure Temp.Rating Temp. Factor Length Identification •ch(mm) psi(bar) °F °C °F °C Inch(mm) Number(SIN) Bulb 1/2"NPT 1/2"(13) 175(12) 155 68 100 38 5.8(83.5) 2.45(62) R A3533 (R'/) 175 79 150 66 •rdinary Temp.Rating Intermediate Temp.Rating Max.Coverage area Max.Spacing 155°F/68°C) (175°F/79°C) Top of Deflector to Minimum Ft x Ft(m x m) Ft(m) Flo Pressure Flow Pressure Ceiling Spacing GPM(L/min) PSI(bar) GPM(L/min) PSI(bar) Inch(mm) Ft(m) 18 x 20(5,5 x 6,1) 18 (5,5) 30(114) 26.: 85) 30(114) 26.8(1,85) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 6,7) 16 (4,9) 33(125) 32.4(2,23) 33 = 32.4(2,23) 1/2(13)recessed using F2 escutcheon 16 x 24(4,9 x 7,3) 16 (4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14 (4,3) 42(160) 52.4(3,75) 42(160) 52.4( , ) 8(2,4) 18 x 20(5,5 x 6,1) 18 (5,5) 35(133) 36.4(2,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16 (4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 6 to 12 to 305); '/(13)rec- ed 16 x 24(4,9 x 7,3) 16 (4,9) 42(160) 52.4(3,6) 42(160) 52.4(3,6) using F2 escutch-:4 14 x 26(4,3 x 7,9) 14 (4,3) 46(174) 62.9(4,34) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D • Model Fl Res 58 HSWX(Bulb) 4 FACE OF FITTING TO — — ..., lirkii iii WALL DIMENSION 1 11/16" MIN. 2 1/4" HOLE DIA. [31.8mm] ---- [57.2mm] y --.-1/8" [3.2mm] CEILING TO DEFLECTOR :7 s 1 r+ , . 7"X 1/2" REDUCER DIMENSION 4- _ %\I -)7_ �,.1i 1 ,4 / 1 75/16" DIA. /inn 116. 1.. `--' I [49.2mm] xii' 1,1111111,71' % 2 27/32" DIA. nn Ilio [72.2mm] L_mL ,_-'—', • I TURN COLLAR UNTIL �� • TIGHT AGAINST SPRINKLER `\`! Model KRes58 HSWX(Link) WRENCH BOSS. f 1/2"[13mm] . 135FG08 ADJUSTMENT / Fl RES 58 HSWX f Fig. 7 al -; t r +0#1 • 9. ' -chnical Data: KRes58 HSWX (RA3593) Nominal Max. Max. Sprinkler Sprinkler •read Ambient K SiOrifice Pressure Temp. Factor Length Identification Inch(mm) psi(bar) °F °C Inch(mm) Number(SIN) Link /2 NPT" 1/2 13) 175(12) 100 38 5.8(83.5) 2.45(62) RA3593 (R 1/2) Ordinary Temp.Rating Top of Deflector to Minimum Max.Coverage area Max.Spacin. (165°F/74°C) Ft x Ft(m x m) Ft(m) Flow Pressure Ceiling Spacing GP min) PSI(bar) Inch(mm) Ft(m) 18 x 20(5,5 x 6,1) 18 (5,5) 29(109) 25(1,72) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) . : (1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 7,3) 16 (4,9) 33(125) 32.4(2, ' 1/2(13) recessed sing F2 escutcheon 16 x 24(4,9 x 7,3) 16 (4,9) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14 (4,3) 42(160) 52.4(3,75) 8(2,4) 18 x 20(5,5 x 6,1) 18 (5,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16 (4,9) 38(144) 42.9(2,96) 6 to 12 (152 to 305); 1(13) Recessed 16 x 24(4,9 x 7,3) 16 (4,9) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) 14 (4,3) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl R es30, 49, Fl R es58, F1 R es76 and Fl R es ter seal assembly shall consist of a Teflon* coated Bel- 44 Sprinklers should be inspected and the sprinkler sys- leville spring washer with top-loaded extruded or cold tern maintained in accordance with NFPA 25, 13, 13D, head cup with 3 mm glass bulb containing no plastic and 13R. Do not clean sprinkler with soap and water,Am- parts, and having a temperature rating of [155°F (68°C)] monia or any other cleaning fluids. R emovedust by using [175°F (79°C)]. Sprinklers shall have a nominal K-factor a soft brush or gentle vacuuming. Remove any sprinkler of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- which has been painted (other than factory applied) or plated] [White Polyester] [Special finish- specify]. R esi- damaged in any way.A stock of spare sprinklers should dential pendent sprinklers shall be R eliableModel Fl R es be maintained to allow quick replacement of damaged or 30, 49 & 58, SIN R 3511, R 3516& R 3513(Bulletin 135). operated sprinklers. Prior to installation, sprinklers should Model Fl Res 49 & 58 Recessed Pendent/F1, remain in the original cartons and packaging until used. Model Fl Res 30, 49 & 58 Recessed Pendent/ This will minimize the potential for damage to sprinklers F2, Model Fl Res 30, 49&58 Recessed Pendent/ that could cause improper operation or non-operation. FP Model Fl Res 30, 49 & 58 Pendent Sprinklers shall be [cULus Listed] [New York City MEA Sprinkler Specifications Approved(258-93-E)] low flow residential recessed pen- Sprinklers shall be [cULus Listed] [New York City MEA dent sprinklers engineered to provide a minimum design Approved(258-93-E)] low flow residential pendent sprin- density of 0.05 gpm/ft2 over the listed coverage area. klers engineered to provide a minimum design density of Listed flows as specified by the manufacturer's technical 0.05 gpm/ft2 over the listed coverage area. Listed flows data sheets are to be used. R esidential sprinklers shall as specified by the manufacturer's technical data sheets be installed in conformance with the manufacturer's in- are to be used. R esidential sprinklers shall be installed stallation guidelines and the applicable installation stan- in conformance with the manufacturer's installation guide- dard. Deflector-to-ceiling distance listing shall be 1" to 8" lines and the applicable installation standard. Deflector- maximum, only for F1R es49. Sprinkler frame and deflec- to-ceiling distance listing shall be 1" to 8" maximum, only tor shall be of bronze frame construction having a 1/2" NPT for F1R es 49. Sprinkler frame and deflector shall be of thread. Water seal assembly shall consist of a Teflon* bronze frame construction having a '/2" NPT thread. Wa- coated Belleville spring washer with top-loaded extruded *DuPont R egisteredTrademark 10. or cold head cup with 3 mm glass bulb containing no leville spring washer with top-loaded extruded or cold plastic parts, and having a temperature rating of [155°F head cup with 3 mm glass bulb containing no plastic (68°C)] [175°F (79°C)]. Sprinklers shall have a nomi- parts, and having a temperature rating of [155°F (68°C)] nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [175°F (79°C)]. The solder element (Link) version, the [Chrome-plated] [White Polyester] [Special finish— spec- water seal consist of a cap with a bellville spring washer ify]. R ecessed escutcheon assembly shall be a steel, and a temperature rating of 165°F (74°C). The recessed two-piece escutcheon [with 1/2" adjustment (Model F2)] assembly forthe HSWX (Bulb & Link) should be a steel [with 3/4" adjustment (Model F1)] [of push-on and thread two pieces escutcheon with 1/2" adjustment (Model F2) off design with '/2" adjustment (Model FP)]. Standard fin- standard finish should be Bright Chrome and white paint- ish shall be [brass][bright chrome] [white painted]. R esi- ed. The Fl R es 58 HSW is also available with low lead dential recessed pendent sprinklers shall be R eliable frame. F1 R es58 HSW and HSWX sprinklers shall have a [Model Fl R es30, 49&58 R ecessedPendent/F1] [Model nominal K Factor of 5.8 and Fl R es44 a nominal K factor Fl R es30, 49&58 R ecessedPendent/F2] [Model Fl R es of 4.4. Standard finish: [Bronze][Chrome-plated] [White 30, 49 & 58 Recessed Pendent/FP]SIN R 3511, R 3516& Polyester] [Special finish— specify]. R esidential horizontal R 3513(Bulletin 135). sidewall sprinklers shall be Reliable Model F1 R es44, F1 Model Fl Res 30, 49 & 58 CCP Pendent Res 58, F1 Res 58 HSWX & Model KR es58 HSWX, SIN (Concealed) R 3531,R A3533& R A3593(Bulletin 135). Sprinklers shall be [cULus Listed] [New York City MEA Model Fl Res 44 Recessed Approved (258-93-E)] low flow residential concealed Horizontal Sidewall Sprinkler sprinklers engineered to provide a minimum design den- Use description for the Model Fl R es44 horizontal side- sity of 0.05 gpm/ft2 over the listed coverage area. Listed wall sprinkler with the following modifications: R eplace flows as specified by the manufacturer's technical data "horizontal sidewall sprinkler" with "recessed horizontal sheets are to be used. R esidential sprinklers shall be in- sprinkler." Add: R ecessedescutcheon assembly shall be stalled in conformance with the manufacturer's installa— tion guidelines and the applicable installation standard. F2).Standard finish shall be [brass][bright chrome] [white Sprinkler frame and deflector shall be of bronze frame painted] [Special finish— specify]. R esidential recessed construction having a 1/2" NPT thread. Water seal as horizontal sidewall sprinklers shall be R eliable Model F1 sembly shall consist of a Teflon*coated Belleville spring R es44/F2,SIN R 3531(Bulletin 135). washer with top-loaded extruded or cold head cup with 3 Model Fl Res 76 Pendent mm glass bulb containing no plastic parts, and having a Sprinklers shall be [cULus Listed] low flow residential temperature rating of 155°F (68°C). Cover plate assem- pendent sprinklers engineered to provide a minimum bly shall consist of a brass cover plate and copper alloy design density of 0.05 gpm/ft2 over the listed coverage retainer flange. Method of attaching the cover plate to the area. Listed flows as specified by the manufacturer's sprinkler cup shall be a push-on and thread-off design technical data sheets are to be used. R esidential sprin- allowing a '/2" cover plate adjustment. Cover plate tern- klers shall be installed in conformance with the manufac- perature rating shall be 135°F (57°C). A plastic protec- turer's installation guidelines and the applicable installa- tive cap shall be provided and factory installed inside the tion standard. Sprinkler frame and deflector shall be of sprinkler cup to protect the sprinkler from damage, which bronze frame construction having a 3/4" NPT thread. Wa- could occur during construction before the cover plate ter seal assembly shall consist of a Teflon* coated Bel- is installed. Standard cover plate finish: [White] [Custom leville spring washer with machined or cold head cup with Color— specify]. ]. Concealed pendent sprinklers shall 3 mm glass bulb containing no plastic parts, and having be R eliable Model F1 Res 30, 49 & 58 CCP, SIN R 3511, a temperature rating of [155°F (68°C)] [175°F (79°C)]. R 3516& R 3513(Bulletin 135). Sprinklers shall have a nominal K-factor of 7.6. Standard Model Fl Res 44, Fl Res 58 Horizontal finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- Sidewall, Fl Res 58 HSWX & KRes58 HSWX cial finish— specify]. R esidential pendent sprinklers shall Residential Sprinkler Specifications be R eliable Model Fl R es 76, SIN R 7618(Bulletin 135). Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. R esiden- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- *DuPont R egisteredTrademark 11. Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, a temperature rating of 155°F (68°C). Cover plate assem- Model F1 Res 76 Recessed Pendent/FP bly shall consist of a brass cover plate and copper alloy Sprinklers shall be [cULus Listed] low flow residential retainer flange. Method of attaching the cover plate to the recessed pendent sprinklers engineered to provide a sprinkler cup shall be a push on and thread off design minimum design density of 0.05 gpm/ft2 over the listed allowing a 1/2" cover plate adjustment. Cover plate tern- coverage area. Listed flows as specified by the manu- perature rating shall be 135°F (57°C). A plastic protec- facturer's technical data sheets are to be used. R esiden tive cap shall be provided and factory installed inside the tial sprinklers shall be installed in conformance with the sprinkler cup to protect the sprinkler from damage, which manufacturer's installation guidelines and the applicable could occur during construction before the cover plate installation standard. Sprinkler frame and deflector shall is installed. Standard cover plate finish: [White] [Custom be of bronze frame construction having a 34" NPT thread. Color—specify]. ]. Concealed pendent sprinklers shall be Water seal assembly shall consist of a Teflon*coated Bel- Reliable Model Fl R es76 CCP, SIN R 7618(Bulletin 135). leville spring washer with machined or cold head cup with Finishes(1) 3 mm glass bulb containing no plastic parts, and hav- Standard Finishes ing a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard Sprinkler Fl, F2,FP Cover Plates finish: [Bronze] [Chrome-plated] [White Polyester] [Spe Escutcheons cial finish— specify]. R ecessed escutcheon assembly Bronze Brass White Painted shall be a steel, two-piece escutcheon [with '/" adjust Chrome Plated Bright Chrome Plated Chrome White and Black White Painted ment (Model F2)] [with 3A" adjustment (Model F1)] [of Polyester(2)Coated push-on and thread off design with '/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] Special Application Finishes [white painted]. R esidential recessed pendent sprinklers Sprinkler F1, F2,FP shall be Reliable[Model F1 Res 76 Recessed Pendent/ Escutcheons Fl] [Model F1 R es 76 Recessed Pendent/F2] [Model Fl Electroless Nickel PTFE(Teflon®))2) Electroless Nickel PTFE(TeflorP) R es76 Recessed Pendent/FP] SIN R 7618(Bulletin 135). Bright Brass Bright Brass Model Fl Res 76 CCP Pendent (Concealed) Black Plated Black Plated Black Paint Black Paint Sprinklers shall be [cULus Listed] low flow residential Off White Off White concealed sprinklers engineered to provide a minimum Chrome Dull Chrome Dull design density of 0.05 gpm/ft2 over the listed coverage (1)Other finishes and colors are available on special order. area. Listed flows as specified by the manufacturer's Consult factory for details. technical data sheets are to be used. R esidential sprin (2)cULus listed corrosion R esistant Note: Paint or any other coating applied over the factory finish will void klers shall be installed in conformance with the manufac- all approvals and warranties. turer's installation guidelines and the applicable installa- Ordering Information tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3A" NPT thread. Wa- Specify: ter seal assembly shall consist of a Teflon* coated Bel- 1. Sprinkler Model leville spring washer with machined or cold head cup with 2. Sprinkler Type 3 mm glass bulb containing no plastic parts, and having 3. Temperature R ating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish "DuPont R egisteredTrademark The equipmentpresented in this bulletinis to be installed in accordancewith the latestpublished Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or othersimilarorganizations and also with the provisions of governmental codes or ordinances wheneverapplicable. Products manufactured and distributed by Reliable have been protecting life and propertyforover90 years,and are installed and serviced by the most highly qualified and reputable sprinklercontractors located throughout the United States,Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co.,Inc. Ai Recycled (800)431 1588 Sales Offices a1► Paper Reliabli (800)848 6051 Sales Fax (914) 829 2042 Corporate Offices R evisionlines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.06/15 P/N 9999970235 WILKINS Model 500 WaterPressure Reducing Valve a ZURN,.company with Inte.ral B -sass Check Valve SPECIFICATION SUBMITTAL SHEET il: APPLICATION Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure.The high flow capacity makes this device most suitable for industrial wa- 1° , �€ t y` 4,ter lines and commercial irrigation systems.The direct act- „;t ing integral by-pass design prevents buildup of excessive . system pressure caused by thermal expansion. The bal- FEATURES anced piston design enables the regulator to react in a Sizes: ❑ 1/2" ❑ 3/4" ❑ 1" ❑ 1 1/4" smooth and responsive manner to changes in system flow ❑ 1 1/2" ❑ 2" ❑ 2 1/2" ❑ 3" demand, while at the same time, providing protection from Maximum working waterpressure 300 psi inlet pressure changes. Maximum working watertemperature 180° F STANDARDS COMPLIANCE Reduced pressure range 25 psi to 75 psi • Factory preset(fieldset 2 1/2" &3") 50 psi ASSES Listed 1003 (1/2" thru 2 1/2" ) Threaded connections(FNPT) ANSI B1.20.1 • IAP MO®Listed(1/2" thru 3" ) Copperconnections(FC) ANSI B 16.22 • City of LosAngelesApproved (1/2" thru 3" ) CPVCtailpiece: Max.hotwatertemp. 180°F @ 100 psi CSA®Certified (1/2" thru 2") Cold waterrated temp. 73.4°F @ 400 psi MATERIALS OPTIONS(Suffixes can be combined) Main valve body Cast bronze ASTM B 584 ❑ - standard with single union FNPT inletx FNPT Access covers Cast bronze ASTM B 584 outlet(1/2"thru 2")and less union (21/2" &3") Brass ASTM B 16 ❑ C - coppersweat connection (1/2" thru 2") Fasteners Stainless steel, 300 series ❑ HR - 75 psi to 125 psi spring range, factory set Stem &plunger Cast bronze ASTM B 584 at 85 psi (fieldset 2 1/2" &3") Brass ASTM B 16 ❑ HLR - 10 psi to 125 psi spring range, factory set Elastomers Buna Nitrile (FDAapproved) at 50 psi EP DM(FDAapproved) ❑ HT - 210°F maximum temp Cap gaskets Natural vulcanized fibre ❑ L - less integral by-pass check valve(3/4"-2") Acetal (DelrinTM 500), NSF Listed ❑ LPV - 210°F maximum temp with 10 psi to 35 psi Springs Oil tempered wire,ASTMA229 spring range, factory set at 20 psi Seat Stainless steel, 300 series ❑ LP C - 180°F maximum temp with 10 psi to 35 psi spring range, factory set at 20 psi - D - LI SC - sealed cage bell housing and stainless steel , adjustment screw ❑ SW - made for salt water service ❑ YSBR - with bronze"Y"strainer on inlet ❑ 510 - 400 psi inlet rating and 75 psi to 125 psi I spring range, factory set at 85 psi B = (fieldset 2 1/2" &3") ❑ P - tapped and plugged forgaugei r , ❑ CP VC - CPVC tailpiece connection(3/4"-1") D WILKINS ACCESSORIES X500- ❑ Repairkit(rubberonly) c DIMENSIONS &WEIGHTS(do not include pkg.) DIMENSIONS(approximate) SIZE CONNECTIONS A B C D WEIGHT in. mm in. mm in. mm in. mm in. mm lbs. kg. 1/2 15 SINGLE UNION 4 1/2 108 6 152 1 5/8 41 2 3/4 70 3 1.5 3/4 20 SINGLE UNION 4 5/8 118 6 152 1 1/8 _ 29 2 3/4 70 4 2.0 1 25 SINGLE UNION 5 1/8 130 6 7/8 175 1 5/8 41 3 5/16 84 6 3.0 1 1/4 32 SINGLE UNION 6 5/16 160 7 1/4 184 - 1 3/4 45 4 - 102 7 3.0 1 1/2 40 SINGLE UNION 8 5/16 211 10 254 1 7/8 48 5 127 14 6.5 2 50 SINGLE UNION 9 1/2 241 10 3/4 273 2 1/8 54 6 1/2 165 20 9.0 2 1/2 65 LESS UNION 10 254 14 1/2 368 3 76 8 203 28 12.5 3 80 LESS UNION 11 1/8 283 16 406 _ 3 1/2 _ 89 8 203 _ 44 20.0 DOCUMENT#: REVISION: REG-500 6/06 Page 1 of 2 FLOW CHARACTERISTICS MODEL 500 1/2" THRU 3" (STANDARD& METRIC) FLOW RATES(Us) 3.2 6.3 9.5 12.6 15.8 18.9 20 1/2" 3/4" 1 1/4" 1 1/2" 2" 2 1/2" 3" =138 N 15 15mm �, (20 mm 32mm 40 mm �� 50 mm� 65mm 80 mm a IIIIIIIIIII��IIIIII ���--- , 104 a LL 10 ������������� 69 u_ LL �if���� — .— ��� LL 0 =m���� ��� 0 �i� � — �� �� __� � 5 I////_ �, —� � ��� 35 LL LL i, �� a 0 I /ry � �---- LL 0 50 100 150 200 250 300 5.5 PSI LOSE @ 53 GPM FLOW RATES(GPM) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 500 may be installed in any position. If installed in a pit or vault, specify the "SC" sealed cage option. Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). CAUT ION: Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing. i ,11. 3 Iu-iii-iii 11111- 1.0 o ■I IIIT-1T-111=11 MODEL 975XL _ o ■1 IILIILI I_ LL I III, ii ��, -III-I I Ii I RPZ BACKFLOW PREVENTER OPTIONAL PR cAUCE e ° III=111=11' PROTECTIVE I ,� - ■III ;� g ENCLOSURE ,a. S ■ �IDD�I�II�, �9�I ID�DIII, 50 1 SHUT-OFF VALVE hi I0 '1Ilai71 OPTIONAL PRESSURE ■ r GAUGE '11' 0411. MODEL DU DIELECTRIC UNION ��� 12"MIN. • ° 30"MAX. II Ill DIF VERTICAL INSTALLATION TIETIEM rifiEr IEHIEI 1 1-1 11-1 11 -1111)111= 111=1111- 11111 =111111- =III-III III -111-1 111=111=I MODEL 500 TO HANDLE LOW 111 11, -111=I DEMANDS SET 65 PSI) - --iil III ( @ DIRECTION OF FLOW aliElimmuilarmilli TYPICAL INSTALLATION 1 1 A • oill is ail s ■.■ MODEL 500 FC TO HANDLE DIRECTION OF FLOW HIGH DEMANDS(SET @ 55 PSI) SPECIFICATIONS BATTERY INSTALLATION The Pressure Reducing Valve shall consist of a bronze body and bell housing, a separate access coverforthe plunger and a bolt to adjust the downstream pressure.The bronze bell housing and access cap shall be threaded to the body and shall not require the use of ferrous screws.The assembly shall be of the balanced piston design and shall reduce pressure in both flow and no-flow conditions. The assembly shall be accessible for maintenance without having to remove the body from the line. The Pressure Reducing Valve shall be a WILKINS Model 500. Page 2 of 2 WILKINS a Zurn company,1747 Commerce Way,Paso Robles,CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA:ZURN INDUSTRIES LIMITED,3544 Nashua Dr.,Mississauga, Ontario L4V 1L2 Phone:905/405-8272Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) - Website: http://www.zurn.com ES-A-20008-FP Series 2000B-FP AMES Double Check Valve Assemblies FIRE&WATERWORKS r Sizes: 1" -2" (25-50mm) 4 • _ � • • `Nts an) Features /_; ',/ • Ease of maintenance with only one r v4 cover 1 • Top entry - • Replaceable seats and seat discs l 2000B-FP • Modular construction A'! • Compact design — ._ i/ • • 1" -2" (25—50mm)Cast bronze .' body construction - • Low pressure drop - _- pr • No special tools required _ • Gear operated, slow close shutoffs • Pre-wired tamper sw itch(2)per Series 2000B-FP Double Check Valve Assemblies shall be installed at referenced cross- shutoff connections to prevent the backflow of polluted water into the potable water supply.Only those cross-corrections identified by local inspection authorities as non-health hazard shall be allowedthe use of an approved double check valve assembly. Pressure — Temperature Check with local authority having jurisdiction regarding vertical orientation,frequency of Temperature Range:33°F—140°F testing or other installation requirements. (0.5°C—60°C) These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross-Comection Control and Hydraulic Research at the Maximum Working Pressure: 175psi University of Southern California. (12.1 bar) Specifications A Double Check Valve Assembly shall be installed at each noted location.The assembly Standards shall consist of twopositive seating check modules with captured springs and rubber seat AWWA Std. C510, IAPMO PS31 discs.The check module seats and seat discs shall be replaceable.Service of all internal components shall be through a single access cover secured with stainless steel bolts.The assembly shall also include tworesilient seated gear operated slow close isolation valves and four resilient seated test cocks.The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross-Comection Control and Hydraulic Research at the University of Southern California.Assembly shall be an Ames Company Series 2000B-FP. Approvals NOTICE O ��pSSIFj�o The information contained herein is not intend- SA® C ® US ed to replace the full product installation and c us safety information available or the experience 1015 B64.5 1" -2" of a trained product installer.You are required to thoroughly read all installation instructions Approved by the Foundation for Cross-Connection Control and Hydraulic Research at and product safety information before begin- the University of Southern California. ping the installation of this product. Horizontal approval on all sizes. Inh Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames Fire&Waterworks product specifications in U.S.customary units and metric are appro timate and are provided for reference only.For precise measurements,please contact Ames Fire&Waterworks Technical Service.Ames Fire&Waterworks reserves the rightto change or modify prodictdesign,construction,specifications,or materials w tout priornotice and w ithoutincurring any obligation to make such changes and modifications on Ames Fire&Waterworks predicts previously or subsequently sold. Dimensions — Weights 111111 • E 1 11111111 PI ice. i-. l • . .: y rll� cm IIIIIIIII11 111��iIMA IIIA• _ roll, - u 1 va'IloiIII ``��� illhIiiilli D p • P A I MODEL SIZE DIMENSIONS WEIGHT A B C D E F G H I in. m m in. m m in. m m in. m m in. m m in. m m in. m m in. m m in. m m in. m m lbs. kgs. 2000B-FP 1 25 131/4 337 4%2 114 3%2 89 1 25 7% 191 53 146 2'/a 73 2'/e 73 14% 365 12.2 5.5 2000B-FP 114 32 15% 397 53/8 136 33/4 95 1% 41 9% 241 6%6 154 2'/a 73 33/6 81 16% 419 17.3 7.8 2000B-FP 11/2 40 163/6 416 5% 143 4 102 1% 41 9% 248 61/4 159 2'/6 73 33/s 86 17 432 19 8.6 2000B-FP 2 50 191/8 486 61/2 165 41/4 108 21/4 54 13% 340 6% 165 2'/6 73 3% 92 19%2 495 26.4 12 Strainer sold separately Capacities As compiled from documented Foundationfor Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests. *Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) kPa psi * 1" (25mm) kPa psi 11/2" (40mm) N 110 16 83 12 J 83 12 0 69 10 O 69 10 0 3 55 8 55 8 0 41 6 y 41 6 in 28 4 3 28 4 �—.-- d 14 2 N 14 2 AP 0 5 10 15 20 25 30 35 40 45 50 55 60 gp a L 0 OPO 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mp• 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps 5 PSI LOSE @ 53 GPM Flow Rate kPa psi 11/4" (32mm) kPa psi 2" (50mm) 96 14 * 83 12 N 83 12 N 69 10 O 69 10 1 _1 55 8 y 55 8 2 41 6 41 6 N 28 4 N 28 4 eii 14 2 O. 14 2 a 0 0 0 25 50 75 100 125 150 175 200 gpm 0 0 1AP 0 95 190 285 380 475 570 665 760 Ipm �P 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 5 7.5 10 15 fps 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate NOTICE Inquire with governing authorities for local installation requirements A A M E S FIRE&WATERWORKS` A Watts Water Technologies Company USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)81-1001-8600 •Fax:(52)81-8000-7091 •AmesFireWater.com ES-A-2000B-FP 1536 ©2015 Ames Fire&Waterworks SYSTEM �$ SENSOR`°' T-Tap WaterflowDetectors System SensorT-Tap Waterflow Detectors aredesigned forprimarysignalingin residential systemsand branch - linesignalingin largersystems. Features Both the WFDTretard model and the WFDTNRnon-retard model fit •Sealed retard mechanism(Model WFDT) any tee that has a 1"NPT branch,including: 1",11/4",11/2"and 2"NPT threaded ferrous and brass tees;1",11/4",1'/z"and 2"cop persweat •Visual switch activation(Model WFDT) tees;Tyco,Spears,Victaulic and NIBO brand 1"CPVC tees;and 11/2" •Twelve different flexible plastic paddles polybutylene tees. •Vertical or horizontal mount Design.The design of the WFDTand WFDTNRmakes them easy •Durable,tamper-resistant enclosure to install and simple to maintain.Eithercan be mounted in the •Dual SPDTswitches in durable terminal block vertical or horizontal position.Two conduit openings permit easy •Siz esmarked on flexible plastic paddles attachment to the local alarm system.The retard mechanism(Model WFDTonly)and switch assemblies are field-replaceable. •100 percentsynchronization activates both alarm panel and local bell •Accommodates up to 12 AWG wire Features Twelve different flexible plastic paddles fit 1",1'/4",1'/z"and 2"tees.Sizes are marked clearly on the paddles forease of installation. Plastic paddles slip overthe actuating leverand are securelyfastened with one screw.The handy depth gauge ensures the proper installation depth and clearance of the detectorto the tee. Construction.TheWFDTand WFDTNRinclude a durable,tamper- resistant enclosure and rugged switch assembly.The robust covers completelyenclose the electrical components to keepout dust and dirt.Improved self-guiding securityscrews and removal tools make the detectors resistant to tampering and simplifyfield maintenance. Dual SPDTswitches are enclosed in a durable terminal blockfor added strength. Agency Listings U ° NOc MEA LISTED ® �R approved 5739 7770-1653:114 167-93-6 T-TapWaterflowDetectorSpecifications Architectural/Engineering Specifications Model shall be a WFDTorWFDTNRas manufactured bySystem Sensor.T-tapwaterflow detectors shall be installed on a tee that has a 1"NPTbranch including: 1",114",11/2"or2"threaded ferrous or brass tee;1-2"coppersweattees;Tyco,Spears, iictaulic7 and NIBCObrand 1"CPVC tees;or 11/2"polybutylene tee as designated on the drawings and/oras specified herein.Detectors shall mounton any clear pipe span of the appropriate size,eithera vertical or horizontal run at least 6"from any fittings or valves that may change waterdirection,flow rate,or pipe diameteror no closerthan 24"from a valve or drain.Detectors shall have a sensitivityin the range of 4 to 10 gallons per minute and a staticpressure rating of 250 psi.The retard t-tapdetectorshall be a sealed mechanical pneumatic unit with visual indication of actuation.The actuation mechanism shall include a polyethylene vane inserted through the tee fitting and connected by a mechanical linkage to the delay mechanism.The non-retard t-tapdetectorshall respond with no time delayto waterflowin the specified direction and range.Outputs shall consistof dual SPDTswitches(Form C contacts).Two conduitentrances(one of which is a knockouttype)forstandard fittings ofcommonlyused electrical conduitshall be provided on the detectors.A grounding provision is provided.All detectors shall be listed by Underwriters Laboratories forindoor or outdoor use. Physical/Operating Specifications Static PressureRating 250 PSI OperatingTemperature Range 32°F to 120°F(0°C to 49°C) Maximum Surge 18 FPS Enclosure Rating UL indoor/outdoorrated TriggeringThreshold 4-10 GPM Coy erTamperSwitch UL models:optional P/N 546-7000 Bandwidth(FlowRate) ULC/Canadian models:factoryinstalled Overall Dimensions, WFDT:4.5"H x 3.75"W x 6.7"L Sery iceUse Automatic Sprinkler:NFPA 13 Installed (11.4cm H x 9.5cmW x 17cm L) One orTwo FamilyDwelling:NFPA 13D WFDTNR:3.75"H x 3.25"W x 4.25"L Residential Occupancies up to 4 Stories:NFPA 13R (9.5cm H x 8.2cmW x 10.8cm L) National Fire Alarm Code:NFPA 72 ContactRatings Two sets ofSPDT(Form C) ShippingWeight WFDT2.6 lbs.(1.2 kg.) 10.0 A @ 125/250VAC WFDTNR:1.5 lbs.(0.7 kg.) 2.5 A @ 24VDC CompatibleTee Threaded ferrous and brass tees,copper Warranty 3 years Fittings sweattees,CPVC tees,and polybutylene tees Conduit Entrances Two openingsfor'/2"conduit. U.S.PatentNumbers 5,213,205 Electrical ConnectionsforWFDT Delay Adjustm entDial SSM24-X NOTE:COMMON AND B-NO DELAY UL-LISTED CONNECTIONS WILL CLOSE ADJUSTMENT COMPATIBLE SSV120-X WHEN VANE IS DEFLECTED,I.E., DIALON DIAL IS qpp WHEN WATER IS NG.DUAL 1110,17,, CP OWER PANEL APPLICATIONS PERM E CIOMBINED ',V" DE1'A'Y VN SFO 04Z/4„.% 24VDC OR ON A SINGLE DETECTOR. 0 120VDC - S I CONTACT RATINGS INITIATING+-SUGGESTED EOL 125/250 VAC 10 AMP SO / h� LOOP RESISTOR 24VDC 2.5 AMP S SCHEMATIC OF c I :(- OO/O/ ' INDIVIDUAL 'CO g dill SWITCH IN ,, +U :Tj } CONDITIONFLOW - o .T. 45 �.. A BiiO B410 A • b BREAKWWIRE AS , �4�•SIIITQI 1 SrmcN 2 "4, SHOWN FOR n.Na 15 SUPERVISION OF 3• cwrw CONNECTION.DO /7J•Y�•rd• INI NIIIIr ��• NOT ALLOW iml:rI I MOM MU _ STRIPPED WIRE 1 1 O• f°) ( =M i(j) LEADS TO EXTEND J` NOTE:RETARD TIME MAY EXCEED 90 SECONDS.ADJUST BEYOND SWITCH AND VERIFY THAT TIME DOES NOT EXCEED 90 SECONDS. HOUSING.DO NOT NUMBER ON DIAL IS APPROXIMATE TIME DELAY IN 0• —.O LOOP WIRES. D SECONDS W ITHAN ACCURACY OF+I-50%. Ordering Information UL Model ULCModel Description WFDT WFDTA Waterflow Detector,Fits 1;11/4",11/2,2"ferrous and brass threaded tees;1",11/4,1'/z",2"coppersweat tees;1"CPVC tees;and 11/2"polybutylene tees WFDTNR — Waterflow Detector,non-retard,fits same tees as Model WFDT Accessories Description A77-01-02 Replacementterminal blockforWFDT A77-01-08 Replacementterminal blockforWFDTNR A3008-00 Replacementretard mechanism PRK9 Replacementpaddle kit–12 paddles forWFDTand WFDTNR(seeWFDTforsiz es) 546-7000 Covertamperswitch kitforWFDT S07-66-02 ReplacementtamperscrewsforcoversofWFDT,WFDTNR WFDW Replacementtamper-proof wrench forcoverof WFDTWFDTNR WFDN4 NEMA-4gasketkit C58-164-01 Replacementmetal cover C58-195-01 Replacementplastic cover(WFDTNR) *--Th_ Spears°is a registered trademarkof the Spears Manufacturing Company.Victaulic°is a registered trademarkoftheVictaulic Companyof America. SYSTEM ®2009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Productspecificationssubjecttochangewithoutnotice.Visitsystemsenwccom for ), SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 currenyaroductinformation,includingthelatestversiorofthisdatasheet. ADS-0195-013•1/09•01923 NI BCD www.nbconcom AH E A D 0 F T H E F L O W' Revision B/1/03 Class 125 Bronze Check Valves Dezincification Horizontal Swing • Regrinding Type • Y-Pattern • Resistant Renewable Seat and Disc 125 PSI/8.6 Bar Saturated Steam to 353°F/178°C 411/411 200 PSI/13.8 Bar Non-Shock Cold Working Pressure T-413 Threaded CONFORMS TO MSS SP-80 MATERIALLIST PART SPECIFICATION S413 1. Bonnet Bronze ASTM B 62 Solder 2. Body Bronze ASTM B62 3. Hinge Pin Bronze ASTMB 140 Alloy C31400 or 0 B 134 Alloy C23000 4. Disc Hanger Bronze ASTMB 62 or 4 0 �� pd�hH 304 Stainless Steel 1/4"thru 3/4"sizes 5. Hanger Nut Bronze ASTMB 16 0 „�4 owl 0 ,' / 6. Disc Holder Bronze ASTMB 62 ��`� 7. Seat Disc Water,Oil or Gas(Buna-N)(W) IIIIIIIIIIII ' Will Steam(TFE)(Y) 19IIIIIdI1IIIIIIIIIIII Bronze ASTMB 62(B) � ��owI K �1Nil Viton®(V) 8. Seat Disc Nut Bronze ASTMB16 or B 62 A T-413-B 9. Hinge Pin Plug Bronze ASTMB 140 Alloy C32000(not shown) NPT x NPT *10. Seat Disc Washer ASTMB 98 Alloy C65500 or ASTMB103 * Sizes 3/4",1",1'/4",1'/s"and 2"only. IC) ��pdA It O 4„,.....0.0 a t0 al d►'!sA DIMENSIONS-WEIGHTS-QUANTITIES _ IIIIIIIIIII .4: Oil Dimensions (�lllllllli ri IlllllllilI Size A B C T-413 S-413 Master �oMoo�u�NM N OMIn. mm. In. mm. In. mm. In. mm. Lbs. Kg. Lbs. Kg. Ctn.Qty. ��Q► Y4 8 2.13 54 1.63 41 1.38 35 0.50 0.23 0.51 0.23 50 T-413-Y % 10 2.13 54 1.63 41 1.31 33 0.47 0.22 0.48 0.22 50 NPT x NPT Y2 15 2.44 62 1.69 43 1.50 38 0.55 0.25 0.55 0.25 50 *t4'�pdNLh 3/4 20 2.94 75 1.88 48 1.88 48 0.90 0.41 0.88 0.40 50 CNNN�I` ` i �a 1 25 3.56 90 2.31 59 2.25 57 1.46 0.66 1.48 0.67 30 1 Y4 32 4.19 106 2.69 68 2.75 70 2.17 0.99 2.22 1.01 20 \ilei 1 Yz 40 4.50 114 2.94 75 1.13 79 2.95 1.34 3.00 1.36 10 Z��• 2 50 5.25 133 3.94 100 3.75 95 4.79 2.17 4.87 2.21 10 -- Ilik\c--- 2 Ye 65 8.00 203 5.06 129 5.06 129 11.48 5.21 10.48 4.76 5 NI".'"lak M 3* 80 9.25 235 6.25 159 6.25 159 17.53 7.96 15.29 6.94 4 Ordering:T-413 and S-413 normally furnished with Bronze Disc(T-413-B)or(S-413-B). I~ C Both available with TFE Steam Disc(T-413-Y),(5-413-Y),or CWP Disc(T-413-W),(S-413-W) S-413-W or 300°F67PSI steam Viton Disc(T-413-V). C x C * -Class 150(433)furnished for these sizes. NIBCO check valves may be installed in both horizontal and vertical lines with upward flow or in any intermediate position. They will operate satisfactorily in a declining plane(no more than 15°). °For detailed Operating Pressure,refer to Pressure Temperature Chart on page 109. Warning-Do Not Use For Reciprocating Air Compressor Service. ® NIBCO INC.WORLDHEADQUARTERS•1516 MIDDLEBURYST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECHSERVICES PH:1.888.446.4226• FAX:1.800.234.0557•INTERNATIONALOFFICE PH:+1.574.295.3221•FAX:+1.574.295.3455 www.nibco.com NI BCD www.nibco.com AHEAD OF THE FLOW® Revised 5/2/2007 300 lb. WWP Bronze Ball Valves Dezincification Fire Protection Valve • Threaded or Grooved Body Style • Full Port Design 1" - 2" • Resistant Standard Port Design 21/ • Accepts Internal Supervisory Switches -- 300 PS1/20.7 Bar Non-Shock Cold Water / , CONFORMS TO MSS SP-110 • FM APPROVED • . UL LISTED FOR INDOOR AND OUTDOOR SERVICE • CALIFORNIA STATE FIRE MARSHAL LISTING NO. 7770-1243:103 APPROVED BY NEW YORK CITY M.E.A. 218-04-E WITH APPROPRIATE NYC INDICATOR. • it\ KT-505-W-8 MATERIAL LISTligh.._ 10 Threaded PART SPECIFICATION 1. Body Bronze ASTM B 584 Alloy C84400 2. Ball Chrome Plated Brass ASTM B 124 Alloy C37700 3. Seat Ring Carbon-filled TFE KG-505-W-8 4. Thrust Washer Reinforced TFE Grooved 5. Stem Bronze ASTM B 371 Alloy C69430 0 6. Stem 0-Ring Nitrile an - 3.84 CI 7. Retaining Washer Brass 0 till- 8. Retaining Ring Steel 0 O 9. Ground Wire Screw Steel o '; i( _°i� 10. 505-8 Act Assy. Brass 0 1� g� ,_,-aJ 0 © "'+ ,/ 11. BodyEnd Bronze ASTM B 584 AlloyC84400 'f*,0..y-.4.- 12. MountingScrew Steel �-Illi `"�'�'� © !11m 111f1 1 13. Lock Washer Steel 0 ��I1�i1�11 IN cl o 14. Handle Pin Brass -�ti -d 15. Hand Wheel Steel/plastisol coated(1174'-21/i) -.B. Brass Tee Handle(1") 16. Indicator Flag Painted Steel 6 4!) 17. Body Gasket Elastomer 18. Lead Screw 0-Ring Nitrile _ ``p1; 19. Thrust Washer Anti friction Polymer itooRsom II i 20. Cover Gasket Neoprene ° T �� _%., y �d �1 21. Flag Seal 0-Ring Nitrile E. � 22. Tamper-Proof Screw Stainless Steel 23. Pipe Plug(-4 units) Stainless Steel(Not shown) m 00 Refer to page 41 for details for TS-2M Sw itchKit. � � 0 KT-505W DIMENSIONS-WEIGHTS-QUANTITIES Dimensions A B Weight Size Threaded Grooved Threaded Grooved C D E F G Cvt Threaded Grooved Box Master In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Value Lbs. Kg. Lbs. Kg.Qty.Ctn.Qty. 1 25 3.33 85 - - 1.66 42 - - 2.11 54 3.81 97 2.31 59 6.14 156 1.75 44 57 6.1 2.77 - - 1 10 1Y4 32 4.18 106 - - 2.09 53 - - 2.46 62 4.21 107 2.72 69 6.33 161 3.50 89 103 7.1 3.23 - - 1 8 11/2 40 4.70 119 - - 2.35 60 - - 2.95 74 4.46 113 2.97 75 6.33 161 3.50 89 143 8.1 3.68 - - 1 4 2 50 5.15 131 6.71 170 2.57 65 3.36 85 3.69 94 4.67 119 3.18 81 6.33 161 3.50 89 245 10.7 4.86 9.7 4.40 1 4 2Y2 65 5.65 144 7.28 185 2.92 74 3.64 93 3.75 95 4.67 119 3.18 81 6.33 161 3.50 89 183 13.0 5.91 12.6 5.73 1 4 t Note:Cv is defined as the flow in GPM that a valve w ill carry w itha pressure drop of 1.0 psi w henthe media is water at 60°F. 4UL APPROVED NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 6 TECH SERVICES PH:1.888.446.4226•FAX:1.888.336.4226•INTERNATIONALOFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com NIBCO www.nibco.corn Alli AD_ `O F THE ILO yn/ Revision 5/14/02 Copper Water Tube continued DIMENSIONAL DATA-COPPER WATER TUBE-TYPE"M" TYPE"M" Hard Drawn Only: 20-ft.(6.1m)Straight Lengths Usage: For general purpose plumbing,heating and drainage installations. Tolerances Hard Drawn (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting Safe Working Nominal Diameter Thickness Per Foot Pressure" Pressures Water Tube Min. Max. Size(In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A 3/8 0.5W (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (015) 4717 (325) 611 (42) 1 1125 (28.58) 1.122 (28.50) 1127 (28.63) 0.035 (0.69) 0.465 (0.21) 3865 (266) 506 (35) 11/4 1.375 (34.93) 1.372 (34.85) 1,377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35) 11/2 1.625 (41.28) 1.621 (4117) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34) 2 2125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 21/2 2,625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28) 3 3125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1,83) 2.620 (1.22) 2665 (184) 380 (26) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (9213) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26) 4 4125 (104.78) 4.121 (104.67) 4127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26) 5 5125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24) 6 6125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (310) 8.920 (4.05) 2000 (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24) 10 10,125 (25718) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24) Note:Information and data contained in these charts,as taken from ASTM Specifications 8 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints "Based on actual laboratory test data provided by Copper Development Association,Inc. `Based upon 150°F(65 6°C)with an allowable stress of 9500 psi(668 kPa). U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. It] NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX 1.800.234,0557•INTERNATIONAL SERVICE PH:+1,574.295.3221 •FAX:+1.574,2953455 Submittal viea 9 Package ProPress® System ❑ Potable Water ❑ Low Pressure Steam O Hydronic Heating 0 F ire Protection O Chilled Water 0 Vacuum O Compressed Air 0 Corgon O Nitrogen N2 0 Oxygen 02 (non medical) ❑ Argon ❑ System Data Sheet 2 ProPress Product Instructions ProPress for 1/2" to 2" copper tubing 3 ProPress XL for 21/4" to 4" copper tubing 4 ProPress° Dimensional Documentation ProPress for 1/" to 2" copper tubing 5 ProPress XL for 21/4" to 4" copper tubing 17 Viega Limited Warranty ProPress° F ittingsAnd Valves 23 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 1 of 23 Submittal viega 9 Package System Data Sheet ProPress®and ProPress XL(Copper)are safe,reliable and economical copper pipe installation systems that use modern cold press connection technology. Viega®ProPress fittings are for use with type K,L and M hard copper tubing from 1/2" to 4" and soft copper tubing in 1/2" to 11/4" diameters.All tubing must comply with the ASTM B88 standard. ,, ProPress fittings are approved for installations in both above and - — ' .•••, below ground applications. Per code,local inspector approval must be obtained prior to installation below ground. ProPress has been used in Europe since the late 1980s and ! p �. _ ,� ,� F. in the United States since the late 1990s for a variety of 1�'_�` ", 4 ;'^ - -, , applications. Backed by two plumbing leaders with over 175 years of combined excellence. Listings and Certificates • NSF 61G • IAPMO PS117 • UL 213 • FM Class 1920 • ICC LC 1002 Approved Applications: • CSA MSE-13 • Potable Water • ABS • Hydronic Heating (w/Glycol) • Chilled Water International Listings and Certificates • Compressed Air • Deutsch Verein des Gas-und Wasserfachese.V. • Non-medical Gases (DVGW) • Fire Sprinkler(175 PSI maximum) • Lloyd's Register(LR) • Low Pressure Steam(15 PSI maximum) • Det Norske Veritas (DNV) • Vacuum (29.2 in. Hg maximum @ 68°F) • Registro Italiano Navale(RINA) In ProPress 1/2" to 4" dimensions,the Smart Connect Feature • Bureau Veritas (BV) assures leakage of liquids and/or gases from inside the system • KIWA past the sealing element of an unpressed connection.The function of this feature is to provide the installer quick and easy Compliant with: identification of connections which have not been pressed prior • ICC International Plumbing Code to putting the system into operation. • IAPMO Uniform Plumbing Code • PHCC National Standard Plumbing Code Recommended Tools: • Florida Building Code,Volume II Plumbing Code • RIDGID RP 200-B (1/2"to 11/4") • NFPA 13, 13D and 13R • RIDGID RP 210-B (1/2"to 11/4") • ASME B16.51 • RIDGID RP 320-E • U.S. Coast Guard • RIDGID RP 330-B or 330-C Viega ProPress fittings are offered in configurations including: • RIDGID RP 340 Elbows,Couplings, Reducers,Tees, Reducing Tees,Threaded • RIDGID CT 400 Adapters, Unions,Caps and Flanges.All threaded 1/2" to 2" Contact your local Viega representative for details on local fittings are Zero Lead bronze. approvals. Operating Parameters Operating Pressure: 200 PSI maximum Test Pressure: 600 PSI maximum Operating Temperature: 0°F to 250°F Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 2 of 23 Submittal viega 9 Package ProPress Product Instructions Viega ProPress® For Types K, L and M Hard Cop p erTubing in 1/2" to 2" and Soft Cop perTubing in 1/2" to 11/4" A WARNING Read and understand all instructions for installing Viega ProPress fittings.Failure to follow all .�r Iinstructions may result in extensive property damage, ✓ ,�� 90 serious injury or death. )ti f/ 1.Cut copper tubing at right angles using displacement- 2.Remove burr from inside and outside of tubing to ,� prevent cutting sealing element 3.Check seal for correct fit. Do not use oils or lubricants. fir -Zjji _���` Use only Viega ProPress Shiny Black EPDM or Dull _ a,.- � Black FKM sealing elements. f 5,, ��-e Note: For applications requiring Viega ProPress with FKM L . , ``r` `\ sealing elements,remove the factory-installed EPDM 4 "~� 5 ( 5 6 sealing element and replace with FKM sealing element. 4.Mark proper insertion depth as indicated by the Viega ProPress Insertion Depth Chart. Improper insertion depth may result in improper seal. -'�- �_,.,^"l=am' 1,.... r � � AW � 5.While turning slightly, slide press fitting onto tubing to �� I 4a "�t 4a j ---''P) j the marked depth. �`' i%f ���"""� �J �o '�l Note: End of tubing must contact stop. f� 6.Insert appropriate Viega jaw into the pressing tool and '��," /� push in, holding pin until it locks in place. 8 9 7.Open the jaw and place at right angles on the fitting. Visually check insertion depth using mark on tubing. 8.Start pressing process and hold the trigger until the jaw Viega ProPress Insertion Depth Chart has engaged the fitting. Tube Size 1/2" 3/" 1" 11/4" 11h" 2" 9.After pressing, the jaw can be opened again. Insertion Depth 3/4" 7/s" 7/s" 1" 17/16" 19/16" Leak Testing with Smart Connecte: Cid4_(4 Unpressed connections are located by = pressurizing the system with air or water. When testing with water the proper pressure range is 15 psi to 85 psi maximum. Leak testing with air can be dangerous at high pressures When testing with compressed air the proper pressure range is 1/ psi to 45 psi maximum. Following a successful leak test,the system may be pressure tested up to 200 psi with air,or up to 600 psi with water,if required by local code requirements or project specifications. Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 3 of 23 Submittal viega 9 Package Viega ProPress°XL (Copper) For Types K,L and M Hard Copper Tubing in 21/2" to 4" ,A A WARNING Read,understand and follow all instructions for installing ProPress XL(copper)fittings.Failure ''•`I �_ to follow all instructions may result in extensive property ________________ � damage,serious injury or death. /\` IF 7-1 k 1. Cut copper tubing at right angles using disp lacement- �,r type cutter or fine-toothed steel saw. 1 Min. 2 2. Keep end of tubing a minimum of 4" away from the contact area of the vise to prevent possible damage to the tubing in the press area $11" 3. Remove burr from inside and outside of tubing to prevent �]It l I _l I ill 11111 I cutting sealing element. 'I, 4. Check seal and grip ring for correct fit.Do not use oils or 10,•1t4.■ ��1 ? Iif lubricants.Use only ProPress Shiny Black EPDM sealing ®•�.= w l� = elements. �� /' 5. Illustration demonstrates proper fit of grip ring, separation � ring and sealing element. 4 6 6. Mark proper insertion depth as indicated by the ProPress XL(copper) Insertion Depth Chart. Improper insertion o depth may result in an improper seal. Cif � oin 7. While turning slightly, slide press fitting onto tubing to the 4r` , • Y# < 7 marked depth. End of tubing must contact stop. ,% ))7t , . 1 8. ProPress XL(copper)fitting connections must be mm ®� gib t#VS:* " performed with ProPress XL-C Rings and V2 ACTUATOR. 7. 7 ` Use of ProPress XL Rings and/or Actuator(for Bronze fittings)will result in an improper connection. See Ridgid 7 8 9 1 Operator's Manual for proper tool instructions. 9. Open XL-C Ring and place at right angles on the fitting. XL-C Ring must be engaged on the fitting bead Check insertion 7& *- N depth. 4® 10. With V2 ACTUATOR inserted into the tool, open the V2 NAltl'iNt Iry ° — or',, ACTUATOR as shown and connect V2 ACTUATOR to the ���, XL-C Ring. ���, r e J 11. Place V2 ACTUATOR onto XL-C Ring and start pressing process. Hold the trigger until the Actuator has engaged 10 11 12 the XL-C Ring. Keep extremities and foreign objects away from XL-C Ring and V2 ACTUATOR during pressing operation to prevent injury or incomplete press ProPress XL(copper)Insertion Depth Chart 12. Release V2 ACTUATOR from XL-C Ring and then remove Tube Size 21/2" 3" 4" the XL-C Ring from the fitting on completion of press. Insertion Depth 111/46" 115/,x' 238" Remove tag from fitting,indicating press has been performed. LeakTesting with Smart Connect"1:Unpressed connections are located by pressurizing the system with air or water.When testing with waterthe properpressure range is 15 psi to 85 psi Leak testing with air can be dangerous at high pressures.When testing with compressed airthe properpressure range is 1/2 psi to 45 psi Following a successful leaktest,the system maybe pressure tested up to 200 psi with air,orupto600 psi with water,if required by local code requirements or project specifications. Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 4 of 23 Submittal viega 9 Package ProPress° Dimensional Documentation ProPress for 1/2" to 2" copper tubing Viega ProPress 90°Elbow Copper P x P- Model 2916 L A Part No. Size A(in) L(in) ,-- 1111111111 l1 1 ,/4 \._k 3/a 77317 '/z"x'/z" 0.75 1.50 A , - 77322 "x 3/4" 1.04 1.94 L �__� 77327 1" x 1" 1.32 2.23 t' � 77332 1'/a" x 1'/a" 1.65 2.68 ?__( 77337 11/2" x 11/2" 1.98 3.40 1 77342 2"x 2" 2.54 4.13 L Viega ProPress 90°Elbow Copper P x P-Model 2916 Short A w Part No. Size A(in) L(in) ®���� 1 77317 '/z"x'/z"1 0.75 1.50 -11 A 411Pa 77022 3/4"x 3/4" 0.76 1.67 Ls 77027 1" x 1" 1.28 2.19 I. 77032 11/4" x1/a" 1.28 2.31 77037 1Y2" x 11/2" 1.29 2.72 1 77042 2"x 2" 2.16 3.74 Viega ProPress 90°Street Elbow Copper P x FTG- Model 2916.1 L A _ Part No. Size A(in) L(in) Li (in) ,CIll, 1 2 I I, 1 77347 Yz"x 1/2" 0.75 1.50 1.54 77352 3/4"x 3/4" 1.04 1.94 1.98 Li i 'i 77357 1" x 1" 1.32 2.23 2.27 l 177362 11/4" x 11/4" 1.65 2.68 2.76 I 77367 11/2" x 11/2" 1.98 3.40 3.48 2 77372 2"x 2" 2.54 4.13 4.20 L > Viega ProPress 90°Street Elbow Copper P x FTG- Model 2916.1 Short A Part No. Size A(in) L(in) L1 (in) 0=- 1. 1 imm-f77347 %2"x 1/z2 0.75 1.50 1.54 L1 77052 3/4"x 3/4" 0.76 1.67 1.83 1 77057 1" x 1" 1.28 2.19 2.27 77062 11/4" x 11/a" 1.28 2.31 2.48 4-2-*1 77067 11/2" x 11/2' 1.29 2.72 2.80 77072 2"x 2" 2.16 3.74 3.78 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 5 of 23 Submittal viega 9 Package _, Viega ProPress 90°Reducing Elbow Copper P x P- Model 2916.3 j1 Part No. Size A(in) Al (in) L(in) Li(in) L I\� 1 2 A 1 '_ 77325 3/4"x'/z" 0.91 0.94 1.81 1.69 -_411111 2 77330 1" x 3/4" 1.20 1.30 2.11 2.21 Al L, +i Viega ProPress 90°Extended Street Elbow Copper P x FTG-Model 2947 • ;moi Part No. Size A(in) L(in) L1 (in) \ 1 2 77353 3/4"x 3/4" 1.02 1.93 5.98 L Viega ProPress 45°Elbow Copper P x P-Model 2926 A Part No. Size A(in) L(in) L A 1 1011 1 1 1 J_ all 77607 1/2"x 1/2" 0.30 1.04 � 77612 3/4"x 3/4" 0.43 1.34 77617 1" x 1" 0.55 1.46 77622 11/4" x 1t/4" 0.68 1.71 77627 11/2" x 11/2" 0.81 2.24 77632 2" x 2" 1.05 2.63 L 1 Viega ProPress 45°Elbow Copper P x P-Model 2926 Short A A • Part No. Size A(in) L(in) 1 L , �I ;\,5\ 77607 %z"x'/zi 0.30 1.04 ®ilb„. • J 77023 3/4"x 3/4" 0.36 1.26 77028 1" x 1" 0.47 1.38 77033 114" x 11/4" 0.58 1.61 77038 11/2" x 11/2" 0.65 2.08 77043 2"x 2" 0.86 2.44 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 6 of 23 Submittal viega 9 Package L Viega ProPress 45°Street Elbow Copper P x FTG-Model 2926.1 A Part No. Size A(in) L(in) L1 (in) , Li 1' .I1I1 1 ��I�1 77637 1 2 12"x1" 0.31 1.06 1.10 j 77642 3/4"x 3/4" 0.43 1.34 1.37 2 77647 1" x 1" 0.55 1.46 •1.49 77652 114" x 114" 0.68 1.71 1.79 77657 11/2" x 112" 0.81 2.24 ..2.32 77662 2"x 2" 1.05 2.63 2.71 L 1 Viega ProPress 45°Street Elbow Copper P x FTG-Model 2926.1 Short A 4- Part No. Size A(in) L(in) L1 (in) ��1 1 2 L1 / - i77637 12"x 12" 0.31 1.06 • 77053 3/4"x 3A" 0.36 1.26 1.30 77058 1" x 1" 0.47 1.38 2 77063 114" x 114" 0.58 1.61 1.67 77068 MIM 112" x 112" 0.65 2.08 77073 2"x 2" 0.86 2.44 2.54 �- �- 1 Part No. 1 Viega ProPress Coupling with Stop Copper P x P-Model 2915 1 ���■__ ,III r.„.III r, Size 1 A(in) L(in) 'N__.���. A 78047 12"x'/" 0.12 1.61 L 78052 3/4"x 3/4" 0.20 2.01 78057 1" x 1" 0.16 1.97 78062 114" x 114" 0.14 2.20 78067 112" x 112" 0.14 2.99 78072 2"x 2" 0.14 3.31 " Viega ProPress Coupling No Stop Copper P x P- Model 2915.3 Part No. Size L(in) 1 II I 1 1 1 78172 12"x'/" 1.61 78177 3/4"x 3/4" 2.01 L 78182 M. 1" x 1" 1.97 78187 114" x 114" 2.20 78192 =NM=112" x 112" 2.99 78197 2"x 2" 3.31 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 7 of 23 Submittal viega 9 Package J. Viega ProPress Extended Coupling Copper P x P- Model 2915.5 1 1 III 1 Part No. 1 Size 1 L(in) 79005 12"x 12" 2.99 79010 3/4"x 3/4" 3.50 79015 1" x 1" 3.74 79020 114" x 114" 4.13 79025 112" x 112" 4.72 79030 2"x 2" 5.31 -�`---�__;__ 2 Viega ProPress Reducer Copper P x P- Model 2915.2 ' . 11 1. Part No. Size A(in) L(in) 1 2 A~ 78147 3/4"x 12" 0.42 2.07 L 15603 1" x 12" 0.71 2.36 78152 1" x 3/4" 0.48 2.29 15593 114" x 3/4" 0.70 2.64 78157 114" x 1" 0.55 2.48 18473 11/2" x 3/4" 0.98 3.33 15588 112" x 1" 0.74 3.07 78162 112" x 114" 0.50 2.96 18468 2" x 3A4" 1.54 4.02 15608 2" x 1" 1.29 3.78 22328 2"x 114" 0.81 3.43 78167 2" x 112" 0.74 3.75 Viega ProPress Reducer Copper FTGx P-Model 2915.1 1 I I�L1II�I. 2 Part No. Size A(in) L(in) 1 2 A 78077 3/4"x 12" 1.42 2.17 L 78082 1" x 12" 1.69 2.44 78087 1" x 3/4" 1.42 2.32 22333 1A" x 12" 1.91 2.74 78092 1A" x 3/4" 1.85 2.76 78097 114" x 1" 1.57 2.48 14543 112" x 3/4" 2.56 3.46 78102 11" x 1" 2.28 3.19 78107 112" x 114" 2.04 3.07 78112 2" x 1" 3.03 3.94 78117 2" x 114" 2.79 3.82 78122 2" x 112" 2.63 4.06 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 8 of 23 Submittal viega 9 Package 4- L2 Viega ProPress Tee Copper P x P x P- Model 2918 - A2 Part No. Size A(in) Al (in) A2(in) L(in) Ll (in) L2(in) 1 1 2 3 NMI 77377 1/2"x 1/2"x 1/2" 0.75 0.75 0.50 1.50 1.50 1.25 L I 1 77382 1/2"x 1/2"x 3/a" 0.91 0.91 0.59 1.65 1.65 1.50 A ■•I III' 15493 1/2"x 1/2"x 1" 1.10 1.10 0.55 1.85 1.85 1.46 3 77387 3/a"x 3/a"x 3/a" 0.85 0.85 0.59 1.75 1.75 1.50 Al I _III1 77392 3/a"x 1/2"x 1/2" 0.69 0.98 0.63 1.59 1.73 1.38 Li I 77397 3/4"x 1/2"x 3/a" 0.85 1.14 0.59 1.75 1.89 1.50 =1 77402 3/"x 3A"x 1/2" 0.69 0.69 0.63 1.59 1.59 1.38 2 77407 3/a"x 3/4"x 1" 0.97 0.97 0.63 1.87 1.87 1.54 77412 1" x 1" x 1" 0.97 0.97 0.79 1.87 1.87 1.69 22263 1" x 1/2"x 3/4" 0.85 1.24 0.75 1.76 1.99 1.66 94767 1"x 1/2"x 1" 0.97 1.52 0.79 1.87 2.26 1.69 77417 1" x 3A"x 1/2" 0.69 0.89 0.79 1.59 1.79 1.54 77422 1" x 3/a"x 3/a" 0.85 1.04 0.75 1.75 1.95 1.65 77427 1" x 3/4"x 1" 0.97 1.18 0.78 1.87 2.07 1.69 77432 1" x 1" x 1/2" 0.69 1 0.69 0.79 1.59 1.59 1.54 77437 1" x 1" x 3A" 0.85 0.85 0.75 1.75 1.75 1.65 15488 1 1" x 1" x 1 1/4" 1.16 1.16 0.84 2.07 2.07 1.87 77442 11/4" x 11/4 x 11/4" 1.02 1.02 0.86 2.05 2.05 1.89 22253 =11/4" x 1/2"x 11/a" 1.02 11.77 0.87 2.05 2.52 1.89 22243 11/4" x 3/a"x 1/2" 0.64 1.13 0.93 1.68 2.03 1.68 22258 -11/4" x 3/4"x 3/a" 0.76 1 1.30 0.87 1.80 2.21 1.78 22268 11/4" x 3/a"x 1" 0.88 1.40 0.91 1.91 2.31 1.82 22248 11/4" x 3/a"x 11/a" 1.02 1.54 .0.86 2.05 2.45 1.89 22238 11/4" x 1" x 1/2" 0.64 0.91 0.93 1.68 1.82 1.68 94762 11/4" x 1" x 3/a" 0.76 1 1.14 1.87 1.79 2.05 1.77 14568 11/4" x 1" x 1" 0.88 1.28 0.91 1.91 2.19 1.81 94757 11/4" x 11/4" x 1/2" 0.65 1 0.65 11.93 1.671 1.67 1.67 77452 11/4" x 11/4" x 3/4" 0.77 0.77 0.89 1.79 1.79 1.77 77447 1/4"x 11/a" x 1" 0.88 1 0.88 13.90 1.91. 1.91 1.81 77457 11/2"x 11/2"x 11/2" 1.13 1.13 1.13 2.56 2.56 2.56 79660 11/2" x 1" x 3/4" 0.67 1 1.39 11.16 2.17 2.44 2.05 15458 11/2"x 1" x 1" 0.74 1.54 1.06 2.17 2.44 1.97 15463 -11/2"x 1" x 11/2" 1.13 1 1.83 11.13 2.56 2.74 2.56 22233 11/2"x 11/a" x 3/4" 0.67 1.08 1.15 2.09 2.11 2.05 15453 -11/2" x 114 x 1" 0.74 1.29 1.18 2.17 2.32 2.09 15483 11/2 x 11/4"x 11/4" 0.86 1.33 1.13 2.28 2.36 2.17 15448 11/2"x 11/2"x 1/2" 0.47 1 0.47 •1.10 1.89 1.89 1.85 77462 11/2" x 11/2"x 3/4" 0.66 0.66 1.14 2.09 2.09 2.05 77467 -11/2"x 11/2" x 1" 0.74 1 0.74 1.18 2.17 2.17 II 2.09 77472 11/2"x 11/2"x 11/4" 0.86 0.86 1.13 2.28 2.28 2.17 77477 12" x 2" x 2" 1.37 1 1.37 1.37 2.95 2.95 II 2.95 15518 2" x 11/4" x 11/4" 0.94 1.84 1.33 2.52 2.87 2.36 15513 2"x 11/2" x 3/4" 0.70 1 1.25 1.38 2.28 2.68 2.28 15498 2" x 11/2" x 1" 0.82 1.45 1.38 2.40 2.87 2.28 15508 2"x 11/2" x 11/a" 0.94 61.55 1.49 2.52 2.97 2.52 Continued on next page Viega LLC,100 N. Broadway, 61h Floor• Wichita, KS 67202• Ph:800-976-9819 • Fax:316-425-7618 SM-PP 1116 9 of 23 Submittal viega 9 Package L2 Copper Tee P x P x P-Model 2918 (continued) A2 Part No. Size A(in) Al (in) A2(in) L(in) L1(in) L2(in) 1 1 2 3 15503 2"x 11/2" x 11/2" 1.13 1.65 1.37 2.72 3.07 2.80 L 1■■�i 22228 2"x 11/2" x 2" 1.38 11 1.89 1.38 2.95 3.33 2.95 � 15538 2"x 2" x 1/2" 0.54 0.54 1.30 2.13 2.13 2.05 ADIN 94777 2"x2"x3/a" 0.79 11 0.79 1.26 2.37 2.37 1 2.17 I 13 Al 94772 2" x 2" x 1" 0.91 0.91 1.30 2.49 2.49 2.21 �--v- Li ! 77487 2"x 2"x 11/4" 1.04 " ■■I 1.04 1.37 2.62 2.62 2.40 I � ,) 77482 2"x 2" x 11/2" 1.13 1.13 1.37 2.72 2.72 2.80 2 Viega ProPress Cap Copper P-Model 2956 t oil. Part No. fig& L(in) D(in) t - 1 77712 I/2" 1 0.92 0.79 77717 3/4" 1.07 0.94 < ° 77722 1.11 0.99 < ° 77727 11/4" 1.32 1.20 77732 ml . 1.62 1.49 77737 2" 1.81 1.69 Viega ProPress Cross-Over Copper P x P-Model 2928 Part No. Size A(in) L(in) H(in) H f IIID II�ll. 1 1 A L 77742 1/2"x 1/2" 3.62 5.12 0.77 77747 3A"x 3A" 4.49 6.30 0.90 Viega ProPress Cross-Over Copper P x FTG-Model 2927 i Part No. Size A(in) L(in) H(in) �' 1 2 A L 78137 1/2"x 1/" 3.83 4.58 1.10 78142 3A"x 3A" 4.64 5.54 1.54 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 10 of 23 Submittal viega 9 Package Viega ProPress Adapter Zero Lead Bronze P x MPT-Model 2911ZL Part No. Size A(in) L(in) i fl 1 2 1 2 79210 '/z"x 3/s" MPT 0.77 1.59 1 79215 1/2"x 1/2" MPT 0.89 1.71 79220 1/2"x 3/4" MPT 1.00 1.83 A 79225 3/4"x 1/2" MPT 1.02 1.93 L 79230 3/4"x 3/a" MPT 1.02 1.93 79235 3/a"x 1" MPT 1.18 2.09 79240 ' x 3/"MPT 1.18 2.09 79245 1" x 1" MPT 1.26 2.17 79250 -' x 11A" MPT 1.54 2.44 79255 11/4" x 1" MPT 1.22 2.24 79260 11/4" x 11/4" MPT 1.34 2.36 79265 11A" x 11/2" MPT 1.48 2.50 79270 11/2" x 11/4" MPT 1.34 2.76 79275 11/2" x 11/2" MPT 1.28 2.70 79280 11/2" x 2" MPT 1.65 3.07 79285 2"x 11/2" MPT 1.54 3.11 79290 2"x 2" MPT 1.50 3.07 Viega ProPress Adapter Zero Lead Bronze P x FPT-Model 2912ZL Part No. Size A(in) L(in) 1 1111-11111 2 1 2 79295 1/z"x 3/s" FPT 0.19 1.42 1 , 79300 1/z x 1/2 FPT 0.25 1.61 79305 1/2"x 3/a" FPT 0.27 1.65 � 79310 3A"x 1/2" FPT 0.33 1.77 AJ79315 3/a"x 3/a" FPT 0.35 1.81 L 79320 1" x 1/z" FPT 0.41 1.85 79325 1" x 3/4" FPT 0.39 1.85 79330 1" x 1" FPT 0.44 2.01 79335 1" x 1A" FPT 0.50 2.09 79340 11/4" x 1/2" FPT 0.37 1.93 79345 11A" x 1" FPT 0.24 1.93 79350 11A" x 11A" FPT 0.34 2.05 79355 11A" x 11/2" FPT 0.42 2.13 79360 11/2" x 11A" FPT 0.26 2.36 79365 11/2" x 11/2" FPT 0.34 2.44 79370 2"x 2" FPT 0.41 2.68 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 11 of 23 Submittal viega 9 Package Viega ProPress Adapter Zero Lead Bronze FTGx MPT-Model 2911.1ZL /���',”: 1 Part No. Size L(in) 1 2 1 2 79375 1"x%"MPT 1.75 79380 1/2"x 1/2" MPT 1.95 79385 1/2"x 3/4"MPT 2.05 L 79390 3/a"x 1" MPT 1.93 79395 3/4"x 3/a"MPT 2.05 79400 1" x 3/4" MPT 2.05 79405 1" x 1" MPT 2.22 79410 11/4" x 11/4" MPT 2.54 79415 11/2" x 11/2" MPT 2.89 79420 2"x 2" MPT 3.33 Viega ProPress Adapter Zero Lead Bronze FTGx FPT-Model 2912.1ZL O`:0=4, Part No. Size A(in) T L(in) 1 _ -_ II ill '12 1 2 79425 Y2"x3/8" FPT 1.10 1.54 1 _ III 79430 t/2"x'/z" FPT 1.22 1.75 79435 1/2"x 3/a" FPT 1.30 1.83 A 79440 3/a"x Y" FPT 1.26 1.79 L 79445 3/4"x 3/4"FPT 1.28 1.83 79455 1" x 1/2" FPT 1.35 1.99 79450 1" x 1" FPT 1.33 1.99 79460 11/4" x 1" FPT 1.65 2.19 79465 11/4" x 11/4" FPT 1.50 2.19 79470 11/2" x 11/2" FPT 1.88 2.56 79475 2"x 2" FPT 2.13 2.95 Viega ProPress 90°Elbow Zero Lead Bronze P x F PT-Model 2914.2ZL L1-* Part No. Size A(in) Al (in) L(in) L1 (in) Al 1 2 _ 79520 1/2"x3/8" FPT 0.94 0.42 1.77 0.83 orir.Ar li 79525 1/2"x 1" FPT 0.94 0.57 1.77 1.10 I� 2 One 79530 3/z"x 3/a" FPT 1.06 0.51 1.89 1.06 A 79535 3/a x'/2 FPT 1.06 0.65 1.97 1.18 L -= 79540 3/4"x 3/a" FPT 1.06 0.57 1.97 1.12 Ii__, y 179545 1" x'/z" FPT 1.06 0.72 1.97 1.26 �_�• 79550 1" x 1" FPT 1.34 0.76 2.24 1.42 79560 1�/a" x 11/4" FPT 1.54 0.89 2.56 1.57 1 79565 11/2" x 11/2" FPT 1.69 1.05 I 3.11 1.73 79570 2"x 2" FPT 2.17 1.35 3.74 2.05 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 12 of 23 Submittal viega 9 Package rL3 " L2-1 Viega ProPress 90°Drop Ear Elbow Zero Lead Bronze P X F PT-Model 2925.5ZL T ` Part No. Size A(in) L(in) Li (in) L2(in) L3(in) JI 2 1 2 A \ y l�� 1 79185 1/2"x%"FPT 0.94 1.77 0.74 0.83 0.67 79190 1/2"x 1/2" FPT 0.94 1.77 0.74 1.10 0.67 L fm---s/ 79195 3/a"x 3/a"FPT 1.06 1.97 0.83 1.12 0.83 1ii I.-1 -*I L1 " Viega ProPress 90°Hi Ear Elbow Zero Lead Bronze P x F PT-Model 2925.2ZL -• Al •-\ 1 I Part No. Size A(in) Al (in) L(in) Li (in) L2(in) 0 � L2 1 2 4� !0I I�-- 2 79205 1/2"x'/2" FPT 0.94 0.57 1.77 1.10 1.07 A -wig L i 1 , Na> 1-1-'1 rL4 1 L3 b-L21 Viega ProPress Double Drop Elbow Zero Lead Bronze P x P x F PT-Model 2928.7ZL cr.!) -41 ` Part No. Size A(in) L(in) L1(in) L2(in) L3(in) L4(in) L I itok,ri�\ ���I ' 78800 t "x 1/2"x Y2"FNPT 1.34 2.17 1.97 1.10 0.67`_7 1 1 11 1_, 78802 3/a"x 3/a"x 1"FNPT 1.54 2.44 1.97 1.10 0.83 2.05 78801 3/4"x 3/4"x 3/4"FNPT 1.54 2.44 1.97 1.12 0.831 1 2 78803 1" x 1" x 1/2"FNPT 1.77 2.68 2.36 1.10 0.87 2.52 F.-L1 Y�II� 1 Viega ProPress Reducer Zero Lead Bronze FTGx P- Model 2915.1ZL ■111111 2 Part No. Size 1 2 A(in) L(in) A 79850 11/2" x'/2" 1.95 2.78 L 79855 2"x 1/2" 2.38 3.21 79860 2"x 3/4" 2.42 3.33 Viega LLC,100 N. Broadway, 6t" Floor• Wichita, KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 13 of 23 Submittal viega 9 Package Viega ProPress Tee Zero Lead Bronze P x P x F PT-Model 2917.2ZL L1-' Part No. Size A(in) Al (in) L(in) Ll (in) Al 1 2 3 14-1 79580 1/2"x 1"x 1/2"FPT 0.79 0.69 1.61 1.30 -� 79585 3/4"x 3/a"x 1/4" FPT 0.67 0.79 1.57 1.18 =�' 79590 3/4"x 3/4"x 1/2" FPT 0.79 0.88 11.69 11.42 L = 79595 3/4"x 3/4"x 3/4"FPT 0.91 0.59 1.81 1.14 A79760 1" x 1" x t/2" FPT 0.79 1.04 11.69 11.57 1 1'117 79765 1" x 1" x 3/4" FPT 0.91 1.06 1.81 1.61 T A 79770 11/4"x 11/4"x 1/2"FPT 0.83 1.16 1.85 1.69 1 79775 1t/4"x 114" x 3/4"FPT 0.95 1.18 1.97 1.73 L ‘= 79780 11/2"x 11/2"x 1/2"FPT 0.87 1.24 2.28 1.77 1 =Q 79785 11/2"x 11/2"x 3/4"FPT 0.94 1.30 2.36 1.85 79790 2"x 2"x 1/2" FPT 0.98 1.59 2.56 2.13 2 79795 2"x 2"x 3/a" FPT 1.06 1.65 2.64 2.20 . 3 . Viega ProPress Vent Tee Zero Lead Bronze P x F PTx P-Model 2917.3ZL Part No. Size A(in) Al (in) A2(in) L(in) Ll (in) L2(in) L1 1 k 1 2 3 Al .!&-,-, j 79635 1"x1/8" FPT x 1/2" 0.67 0.67 0.44 1.50 1.50 0.71 79640 3A"x1/8" FPTx 344" 0.83 0.83 0.54 1.73 1.73 0.81 1 2 t A A2. L L2-. _ Viega ProPress Union Zero Lead Bronze P x P-Model 2960ZL ,iI i1i1r, } Part No. Size A(in) L(in) 1 "111 UII 79125 1/2" 1.19 2.84 A 79130 3/" 1.34 3.15 79135 1" 1.83 3.65 L 79140 11/4" 1.64 3.69 79145 11/2" 2.13 4.96 79150 2" 2.07 5.22 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 14 of 23 Submittal viega 9 Package Viega ProPress Union Zero Lead Bronze P x FPT-Model 2962ZL ;r� !!■■I f Part No. Size A(in) L(in) 1 ,I..I 2 1 2 --tr- =••I 79700 Y2"X Y2" FPT 0.91 2.27 79705 3/4"x 3/4" FPT 0.96 2.42 A 79710 1" x 1" FPT 1.31 2.88 L 79715 11/4" x 11/4" FPT 1.27 2.97 79720 11" x 11/2' FPT 1.77 3.87 79725 2" x 2" FPT 1.65 3.92 Viega ProPress Union Zero Lead Bronze P x MPT-Model 2965ZL ���� ui• Part No. Size A(in) L(in) 1 1111 1 2 1 2 -tii--.7.., 79730 1/2"x 1/2" MPT 1.86 2.69 A 79735 3/4"x 3/4" MPT 2.00 2.90 79740 1" x 1" MPT 2.54 3.45 L 79745 11/4" x 11/4" MPT 2.49 3.52 79750 11/2" x 11/2" MPT 3.05 4.47 79755 2"x 2" MPT 2.99 4.57 Viega ProPress Dielectric Union Zero Lead Bronze P x F PT-Model 2967ZL r A_ �\\` Part No. Size A(in) L(in) 1 II IIIIII III' 2 79155 Y2"x Y2" FPT 0.88 2.24 I�IIIIILJII'`\. .1 � 79160 3/4"x 3/4" FPT 1.11 2.57 ,, 79165 1" x 1" FPT 1.00 2.57 / 79170 1A" x 11/4" FPT 0.97 2.68 A 79175 11/2" x 11/2' FPT 1.01 3.11 L 79180 2"x 2" FPT 1.26 3.53 ..-% Viega ProPress Tailpiece Zero Lead Bronze P x F BSP- Model 2957ZL Part No. Size A(in) L(in) 1 I 2 1 2 L79800 Y2"x 1" BSP 0.39 1.57 Nip 79805 3/4"x 1" BSP 0.63 1.87 A 79810 1" x 1" BSP 0.91 2.14 L 79815 1" x 11" BSP 0.73 2.04 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 15 of 23 Submittal viega 9 Package FA Viega ProPress Adapter Flange Zero Lead Bronze P x Flange-Model 2959.5ZL Part No. Jize L(in) A(in) b(in) D(in) k(in) d(in) 1 111 � d 79680 2.76 1.85 0.84 4.33 3.11 0.63 1 79685 1A" 2.76 1.73 0.84 4.53 3.50 0.63 Ins'* 79690 11" 3.07 1.65 0.84 4.92 3.86 0.63 79695 2" 3.66 2.09 0.84 5.91 4.76 0.75 < � k o - bI-<- < L- < D > Viega PEX Press Adapter Zero Lead Bronze P x P-Model 2813PZL T Part No. Size A(in) L(in) 1 2 _.._.__._._.__.____...__._._.._,_._ 2 99620 1/2"x 1/2" 0.29 1.61 -t< W 99626 1/2"x 34" 0.43 1.83 99630 3/4"x 1/2" 0.23 1.56 A 99640 3/4"X 3/4" 0.33 1.73 99660 1" x 1" 0.45 1.97 99670 11/4" x 11/4" 0.49 2.38 99680 ! 11/2" x 11/2" 0.59 2.87 99690 2"x 2" 0.58 3.21 Viega ProPress Venturi Insert Zero Lead Bronze-Model 2911.5ZL • L ► 4-A-1 r-A2 ► Part No. Size A(in) A2(in) L(in) 1 ? 1 2 Flow 1 78810 11/4" x 11/4" 1.02 1.60 3.07 1 - - - � . --�I - 2 78811 11/2" x 11/2" 1.43 2.10 3.98 i 78812 2" x 2" 1.58 2.45 4.48 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 16 of 23 Submittal viega 9 Package ProPress XL for 21/4" to 4" copper tubing L Viega ProPress XL-C 90°Elbow P x P-Model 0916XL A Part Number Size 1 1 A(in) L(in) -I IIIIII 1 A A I ,,,„ 1 20623 21"x 21/2" 3.19 4.88 20628 3"x 3" 3.76 5.73 L 20633 4"x 4" 4.90 7.26 1 y L Viega ProPress XL-C 90°Street Elbow P x FTG-Model 0916.1XL .1-A-k . 11111-1 Part Number Size A(in) L(in) Li (in) 1 2 120638 21/2"x 21/2" 3.19 4.88 4.80 Arillift20643 3"x 3" 3.76 5.73 5.63 Lt i 20648 4"x 4" 4.90 7.26 7.13 it 2 *-L Viega ProPress XL-C 45°P x P-Model 0926XL fA L °A4111111 Part Number Size A(in) L(in) 1 1 VP111111 ' 1 20653 21/2"x 21" 1.48 3.18 20658 3"x 3" 1.73 3.70 1 ` 20663 4"x 4" 1.96 4.63 -L- Viega ProPress XL-C 45°Street Elbow P x FTG- Model 0926.1XL Part Number Size A(in) L(in) L1 ( in) 111I -II 1 1 2 IIII 20668 21/2"x 21/2" 1.48 3.18 3.10 i 20673 3"x 3" 1.73 3.70 3.60 20678 4"x 4" 2.23 4.59 4.45 2 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 17 of 23 Submittal viega 9 Package Viega ProPress XL-C Coupling with Stop P x P-Model 0915XL 1 rifingit ♦ Part Number 1Size1 A(in) L(in) 111111.111.020728 21/2"x 21/z" 0.95 4.33 i 20733 3"x 3" 0.98 4.92 A 20738 4"x 4" 1.06 5.79 -4 L Viega ProPress XL-C Coupling No Stop P x P-Model 0915.5XL 1 IIMIlii * Part Number 1Size1 L(in) III I I. i 20743 20748 21/2""x 3/z" 4.33 4.92 20753 4"x 4" 5.79 -4 L-11. Viega ProPress XL-C Reducer P x P-Model 0915.2XL Part Number Size A(in) L(in) 1--II, 1 2 1i 1111 I li 20685 21/z"x 1" 1.76 4.36 20690 2/z"x 11/4" 1.61 4.34 Ld1 1 -I �! 20695 21/2"x 11/2" 1.52 4.64 20700 21/2"x 2" 1.41 4.69 1-4-A-r. 20705 3"x 11/2" 1.78 5.17 L-10- 20710 3"x 2" 1.53 5.08 20715 3"x 21/2" 1.41 5.07 20720 4"x 2" 2.06 6.00 20725 4"x 21/2" 1.93 5.99 20730 4"x 3" 1.70 6.03 Viega ProPress XL-C Reducer FTGx P- Model 0915.1XL iii I'IIPart Number Size 1 2 A(in) L(in) 20814 3.61 4.52 1 M111.111 2• 20815 2 z"x VA" 3.47 4.51 A; 20813 21/2"x 11/2" 3.41 4.84 1 '' L 20758 21/2"x 2" 2.35 3.94 20817 3"x 11/4" 3.96 5.00 20818 3"x 11/2" 3.91 5.34 20763 3"x 2" 2.98 4.57 20768 3"x 21/2" 2.76 4.45 20773 4"x 2" 4.58 6.17 20778 4"x 21/2" 4.45 6.15 20783 4"x 3" 4.17 6.14 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 18 of 23 Submittal viega 9 Package Viega ProPress XL-C Adapter P x MPT-Model 0911XL ---__� Part Number Size A(in) L(in) 1 III`I lire 1 , 2 2.76 4.45 1 II MIN U•! 2 20828 208232 3"x 3'' MPT T 2.84 4.80 20838 4"x 4" MPT 3.10 5.46 A- L Viega ProPress XL-C Adapter P x F PT-Model 0912XL L A Part Number Size A(in) L(in) 1 2 = -I --."r"!�='= 20819 21/2"x 21" FPT 1.53 4.15 1 i 20829 3"x 3" FPT 1.84 4.82 li 1 - IU - 2 20839 4"x 4" FPT 2.09 5.55 1I+, Viega ProPress XL-C Tee P x P x P-Model 0918XL L1 Part Number Size A(in) Al(in) A2(in) L(in) Li(in) L2(in) -4-A1y 1 2 3 -4-1-. 20684 21/2"x 3/a"x 21/2" 1.83 1.91 3.23 3.52 3.60 4.13 • vl 20689 21/2"x 1" x 21/2" 1.83 1.91 3.25 3.52 3.60 4.15 ��jl 20694 21/2"x 11/4" x 21/2" 1.83 1.91 3.20 3.52 3.60 4.23 L ___l 206992Y2"x 11/2" x 21" 1.83 1.91 3.14 3.52 3.60 4.57 Ilt 20704 21/2"x 2"x 3/4" 1.04 1.61 1.59 2.74 2.52 3.17 A2 ,I 111_1 20709 21/2"x 2"x 1" 1.04 1.77 1.65 2.74 2.67 3.24 L2 -1 22283 21/2"x 2"x 11/2" 1.30 1.78 2.07 2.99 3.20 3.66 MMI 22278 21/"x 2"x 2" 1.50 1.78 2.25 3.19 3.36 3.83 1.-2-.120714 21/"x 2"x 21/2" 1.83 1.91 2.41 3.52 3.60 4.00 22303 21/2"x 21/"x1/2" 0.91 1.52 0.91 2.60 2.27 2.60 22298 21/2"x 21/"x 3A" 0.91 1.58 0.91 2.60 2.48 2.60 22293 21/2"x 21/2"x 1" 1.04 1.77 1.04 2.74 2.68 2.74 22288 21/2"x 21/2"x 11/a" 1.16 1.76 1.16 2.85 2.79 2.85 20803 21/"x 21/2"x 11/2" 1.30 1.78 1.30 2.99 3.21 2.99 20688 21/2"x 2/"x 2" 1.54 1.75 1.54 3.23 3.34 3.23 20683 21/2"x 21/2"x 21/2" 1.83 1.94 1.83 3.52 3.63 3.52 20719 3"x 3/4"x 3" 2.07 2.15 3.82 4.04 4.11 4.72 20724 3"x 1" x 3" 2.07 2.15 3.96 4.04 4.11 4.86 20729 3"x 11/4" x 3" 2.07 2.15 3.83 4.04 4.11 4.86 Continued on next page Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 19 of 23 Submittal viega 9 Package Viega ProPress XL-C Tee P x P x P-Model 0918XL (continued from previous page) ri-L1-o- Part Number Size A(in) Al(in) A2(in) L(in) L1(in) L2(in) -4-A1-N. 1 2 3 20727 3"x 11/2" x 3" 2.07 2.15 3.71 4.04 1.11 5.14 1 20732 3"x 2"x 2" 1.56 2.03 2.33 3.52 3.61 3.92 MM. 20732 3"x 2"x 21/2" 1.85 2.15 2.63 3.82 3.8 4.21 A Nale 207393"x 2"x 3" 2.07 2.15 2.84 4.04 4.11 4.43 A 20744 3"x 21/2"x 2" Mr.56 2.03 2.07 13.52 3.611 3.76 A2illIIIIIII I i 20749 3"x 21/2"x 21/2" 1.85 2.15 2.56 3.82 3.85 4.25 20754 3"x 21/2"x 3" .l 2.15 2.78 '4.04 4.11 4.47 __?, 20759 3"x 3"x 1/2" 0.93 1.76 0.93 2.89 2.50 2.89 1.-2-1-1 22323 3"x 3"x 3/a" .93 1.80 0.93 2.89 2.71 2.89 22308 3"x 3"x 1" 1.06 2.02 1.06 3.03 2.92 3.03 22313 3"x 3"x 11/4" sliM 2.01 1.18 1 3.15 p.04 3.15 20798 3"x 3"x 11/2" 1.32 2.03 1.32 3.29 3.45 3.29 20698 3"x 3"x 2" aim 2.00 1.56 1 3.52 Lia. 3.52 20703 3"x 3"x 21/2" 1.85 2.15 1.85 3.82 3.85 3.82 20693 3"x 3"x 3" 2.07 2.21 2.07 1 4.04 4.18 4.04 20774 4"x 3"x 2" 1.59 2.57 3.33 3.96 4.15 5.22 20784 4"x 3"x 3" Ir. 2.66 3.84 '4.47 4.63 5.81 20788 4"x 4"x 1/2" 1.08 2.24 1.08 3.45 2.99 3.45 20793 4"x 4"x 3/4" M.O. 2.32 1.08 '3.45 ll. 3.45 20794 4"x 4"x 1" 1.36 2.52 1.36 3.72 3.42 3.72 20795 4"x 4"x 1Y" 1.36 2.50 1.36 3.72 I.54 3.72 20808 4"x 4"x 11/2" 1.36 2.52 1.36 3.72 3.95 3.72 20713 4"x 4"x 2" 1111. 2.53 1.59 13.96 3.96 20718 4"x 4"x 21/2" 1.89 2.65 1.89 4.25 4.35 4.25 20723 if 4"x 4"x 3" MEW 2.69 2.11 1 4.47 Ir.r. 4.47 20708 4"x 4"x 4" 2.60 2.72 2.60 4.96 5.09 4.96 .1--L1 Viega ProPress XL-C Tee P x P x F PT-Model 0917.2XL -4--Al -0-1 Part Number Size A(in) Al (in) L(in) Ll (in) ks zl 1 2 3 L I 20883 21/2"x 21/2"x 3/4"FPT 1.02 1.78 2.72 2.34 r 20878 21/2"x 21/2"x 2"FPT 1.54 1.90 3.23 2.60 A lMM ]: i 4 3 20893 3"x 3"x3/4"FPT 1.04 2.03 3.01 2.59 A IME'"'� 20888 3"x 3"x 2"FPT 1.56 2.16 3.52 2.85 L 'W 20873 4"x 4"x 3/4"FPT 1.08 2.53 3.34 3.09 �r 20868 4"x 4"x 2"FPT 1.59 2.69 3.96 3.38 .1-2-... Viega LLC,100 N. Broadway, 6t" Floor• Wichita, KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 20 of 23 Submittal viega 9 Package Viega ProPress XL-C Cap P-Model 0956XL NW .I I'I' ? Part Number S1 e A(in) L(in) •11100 20833 21/2" 0.39 2.11 20843 3" 0.39 2.36 A 20848 4" 0.39 2.76 L L A ''/Oi Viega ProPress XL-C Adapter Flange P x Flange-Model 0959.5XL ' Part Number Size Ain LinbinkinDind(in) IF1 1141111.1 � I 20853 2Y 1.09 2.79 0.70 5.51 7.09 0.75 r- =' 11111114.0 20858 3" 1.20 3.17 0.79 5.98 7.48 0.75 k D L A rii Viega ProPress XL-C Adapter Flange P x Flange-Model 0959.5XL rd ON d Part Number Size A(in) L(in) b(in) k(in) D(in) d(in) Ili 1 20863 4" 1.29 3.66 0.86 7.52 9.06 0.75 Pi k D Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 21 of 23 Submittal viea 9 Package A A il�� n111. I Gil EIE B II IP Y OE) C 1 ri jiii y I _' I 120 .1 Ion <-E-• H Butterfly Valve-Model 2873.81 Part No. Size A(in) B(in) C(in) D(in) -I F(in) G(in) H(in) I(in) 22074 2'/" 6.50 7.40 2.17 0.ffmM.I1 2.64 5.35 5.20 5.51 22075 3" 7.28 7.64 2.80 0.67 1.81 2.82 5.59 7.01 5.98 < A P-I ■� � IPA B. Jr .P� iai on • 1166)(J1) c `��� > » F H l 'VW kE-. H Butterfly Valve-Model 2873.81 Part No. Size A(in) B(in) C(in) D(in) E(in) F(in) G(in) H(in) I(in) 22076 4" 9.06 8.47 3.54 0.91 2.05 3.62 6.42 8.27 7.48 Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 22 of 23 Submittal viega 9 Package Viega Limited Warranty ProPress° FittingsAnd Valves Subject to the conditions and limitations in this Limited warranty. The part or parts which you claim failed should Warranty, Viega LLC (VIEGA) warrants to wholesalers be kept and Viega contacted by writing to the address and licensed plumbing and mechanical contractors below or telephoning 1-800-976-9819 within thirty(30) in the United States and Canada that its PRO PRESS days after the leak or other failure and identifying yourself fittings, when properly installed in non industrial and as having a warranty claim. You should be prepared to non marine applications and under normal conditions ship,at your expense, the product which you claim failed of use, will be free of failure from manufacturing defect due to a manufacturing defect and document the date of for a period of fifty(50)years from date of installation installation Within a reasonable time after receiving the and that its PROPRESS valves, when properly installed product,Viega will investigate the reasons for the failure, in non industrial and non marine applications and under which includes the right to inspect the product at Viega. normal conditions of use, will be free of failure from Viega will notify you in writing of the results of its review. manufacturing defect for a period of two(2)years from date of installation In the event that Viega determines that the failure or leak was the result of a manufacturing defect in the part Under this Limited Warranty, you only have a right to a covered by this warranty and that this warranty applies, remedy if the failure or leak resulted from a manufacturing the EXCLUSIVE AND ONLY REMEDY under this warranty defect in the products covered by this warranty and the shall be the reimbursement for repair and/or replacement failure or leak occurred during the warranty period. You do of the part VIEGA SHALL NOT BE LIABLE FOR ANY not have a remedy under this warranty and the warranty CONSEQUENTIAL OR OTHER DAMAGE (FOR EXAMPLE, does not apply if the failure or any resulting damage is WATER OR PROPERTY OR MOLD REMEDIATION) caused by(1)components other than those manufactured UNDER ANY LEGAL THEORY AND WHETHER or sold by Viega;(2)not designing, installing, inspecting, ASSERTED BY DIRECT ACTION, FOR CONTRIBUTION or testing the ProPress fittings or valves in accordance OR INDEMNITY OR OTHERWISE. with Viega's installation instructions in effect at the time of the installation; applicable code requirements; and THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER accepted industry practice; (3)improper handling and WARRANTIES, EXPRESS OR IMPLIED, INCLUDING protection of the product prior to and during installation, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF inadequate freeze protection, exposure to water pressures MERCHANTABILITY AND FITNESS FOR A PARTICULAR or temperatures or in applications outside acceptable PURPOSE. If a limited warranty shall be found to apply, operating conditions; (4)acts of nature such as, but not such warranty is limited to four years Other than this limited to,earthquakes, fire,flood, or lightning, or(5) Limited Warranty, Viega does not authorize any person external environmental causes, such as water quality or firm to create for it any other obligation or liability in variations, aggressive water, or other external chemical or connection with its products. physical conditions This Limited Warranty gives you specific legal rights and In the event of a leak or other failure of the parts covered you also may have other rights which may vary from state by this warranty, it is the responsibility of the property to state. This warranty shall be interpreted and applied owner to obtain and pay for repairs Only if the warranty under the law of the state in which the product is installed applies will Viega be responsible for the remedy under this and is intended as a Commercial Warranty. *Zero Lead identifies Viega products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372(Q25% or less maximum weighted average lead content). Viega products are designed to be installed by licensed and trained plumbing and mechanical professionals who are familiar with our products'proper use and installation.Installation by non-professionals may void Viega LLC's warranty. This document subject to updates For the most current Viega technical literature please visit www.viega.us. Click Services->Click Electronic Literature Downloads->Select Product Line->Select Desired Document Viega LLC,100 N. Broadway, 6th Floor•Wichita,KS 67202• P h:800-976-9819 • Fax:316-425-7618 SM-PP 1116 23 of 23 Submittal viea 9 Package ProPress® Valves for Copper and Stainless Steel ❑ Potable Water 0 Argon ❑ Hydronic Heating ❑ Low Pressure Steam ❑ Chilled Water 0 Vacuum ❑ Compressed Air ❑ Oxygen 02 (non medical) ❑ Nitrogen N2 0 Other Approved Application ProPress Zero Lead Ball Valves Model 2971.1 ZL 2 Model 2970.1 ZL 3 Model 2971.3 ZL 4 Model 2970.3 ZL 5 Model 2971.4 ZL 6 Model 2971.6 ZL 7 Model 2974 ZL 8 ProPress Ball Valves for Non-potable Applications Model 2973 9 Model 2973.1 10 Model 2973.3 11 ProPress Stainless Steel Ball Valves Model 4070 12 Model 4370.8 13 Valve Accessories by Model 14 Product Instructions for ProPress Ball Valves 15 Viega Limited Warranty ProPress° Fittings and Valves 16 Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 1 of 16 Submittal viega 9 Package Viega ProPress® Ball Valve - Zero Lead* Model 2971.1 ZL DescriptionZEROLEAD. The Zero Lead bronze ball valve is equippedwith a full port,Zero Lead bronze body.The ball valve features EPDM sealing elements, EPDM stem seals and Viega's Smart Connect°feature for easy identification of unpressed connections during pressure testing. " . ./.."-' :24 4 Features •316 stainless steel ball Alj' j :f • Eco Brass°blowout-proof stem • Lockable metal handle ( 'r-t� • Reinforced PTFE seats • Smart Connect feature - Ratings •250 CWP •Temperature Range:0°F-250°F Component Material • Max. Operating Pressure:250 psi Body Zero Lead Bronze C87700 Ball 316 Stainless Steel Approvals Seat Reinforced PTFE • Conforms to MSS SP-110 Stem Eco Brass C69300 • NSF- UP Code Stem Seals EPDM • NSF 61 Annex G Nut Zinc plated Steel •ASME A112.4.14 • Listed by NSF to Commercial Hot Handle Zinc plated Steel Handle Cover Polyvinyl e * ,F 150 9001 Sealing Element EPDM Registered L2 Part No. Size(1) A(in) Al (in) L(in) L 1(in) L2(in) H(in) H "1"i" 79920 1/2" 0.75 0.75 1.57 1.57 4.57 1.97 �I�I `��` "` 79925 31" 0.85 0.87 1.75 1.77 4.57 2.09 I1114 i1 79930 1" 1.02 1.06 1.93 1.96 5.75 2.46 79935 11" 1.14 1.12 2.17 2.15 5.75 2.67 A Al L L1 "Zero Lead identifies Viega products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372(0.25%or less maximum weighted average lead content). Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 2 of 16 Submittal viega 9 Package Viega ProPress° Ball Valve - Zero Lead* Model 2970.1 ZL Description ZEROLEAD. The Zero Lead bronze ball valve is equippedwith a full port,Zero Lead bronze body.The ball valve features EPDM sealing elements, EPDM stem seals and Viega's Smart Connect°feature for easy identification of unpressed connections during pressure testing. �� �, Features •316 stainless steel ball • Eco Brass°blowout-proof stem • Lockable metal handle • J i • Reinforced PTFE seats R -` • Smart Connect feature Ratings •250 CWP •Temperature Range:0°F-250°F Component Material • Max. Operating Pressure:250 psi Body Zero Lead Bronze C87700 Ball 316 Stainless Steel Approvals Seat Reinforced PTFE • Conforms to MSS SP-110 Stem Eco Brass C69300 • NSF- UP Code Stem Seals EPDM • NSF 61 Annex G Nut Zinc plated Steel •ASME A112.4.14 • Listed by NSF to Commercial Hot Handle Zinc plated Steel Handle Cover Polyvinyl �• * ,• ,* 150 9001 Sealing Element EPDM Registered L3 L2 .�„ Part No. Size(1) A(in) Al (in) L(in) L 1(in) L2(in) L3(in) i " \\�' \` 1 1 79115 1'h" 1.50 1.39 2.91 2.80 3.36 6.12 1111110 79120 2" 1.77 1.83 3.35 3.40 3.67 6.12 A Al L L1 "Zero Lead identifies Viega products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372(0.25%or less maximum weighted average lead content). Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 3 of 16 Submittal viega 9 Package Viega Pro Press® Ball Valve - Zero Lead* Model 2971.3 ZL Description The Zero Lead bronze ball valve is ZERO LEAD. equippedwith a full port,Zero Lead bronze body.The ball valve features EPDM sealing elements, EPDM stem seals and Viega's Smart Connecta feature for easy identification of unpressed connections during pressure testing. Features s •316 stainless steel ball S° ..; •316 stainless steel blowout-proof stem • Lockable metal handle '�" —.__lb i • Reinforced PTFE seats ,,r., _,. • Smart Connect feature a, , t. # Ratings •250 CWP Component Material •Temperature Range: 0°F-250°F Body Zero Lead Bronze C87700 • Max.Operating Pressure:250 psi Ball 316 Stainless Steel Seat Reinforced PTFE Approvals Stem 316 Stainless Steel • Conforms to MSS SP-110 Stem Seals EPDM • NSF-UP Code • NSF 61 Annex G Nut Zinc plated Steel •ASME A112.4.14 Handle Zinc plated Steel •Listed by NSF to Commercial Hot Handle Cover Polyvinyl 15 0 901 Sealing Element EPDM Registered L2 Part No. Size(1) A(in) Al (in) L(in) L 1(in) L2(in) H(in) H .;47-** 79923 1/2" 0.75 0.75 1.57 1.57 4.57 1.97 �-It 79928 3/4' 0.85 0.87 1.75 1.77 4.57 2.09 11 111111111111-" 1 79933 1" 1.02 1.06 1.93 1.96 5.75 2.46 79938 11/4" 1.14 1.12 2.17 2.15 5.75 2.67 A Al L Ll °Zero Lead identifies Viega©products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372(0.25%or less maximum weighted average lead content). Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 4 of 16 Submittal viega 9 Package Viega ProPress° Ball Valve - Zero Lead* Model 2970.3 ZL Description , ZEROLEAD. The Zero Lead bronze ball valve is --------- ��� equippedwith a full port,Zero Lead bronze body.The ball valve features EPDM 40. sealing elements, EPDM stem seals and • • Viega's Smart Connect°feature for easy identification of unpressed connections .31...during pressure testing. ,,..,, 711110 Features _fI� viiiiga- / •316 stainless steel ball •316 stainless steel blowout-proof stem • Lockable metal handle M "~ eri It • Reinforced PTFE seats • Smart Connect feature Ratings •250 CWP •Temperature Range:0°F-250°F Component Material • Max. Operating Pressure:250 psi Body Zero Lead Bronze C87700 Ball 316 Stainless Steel Approvals Seat Reinforced PTFE • Conforms to MSS SP-110 Stem 316 Stainless Steel • NSF- UP Code Stem Seals EPDM • NSF 61 Annex G Nut Zinc plated Steel •ASME A112.4.14 • Listed by NSF to Commercial Hot Handle Zinc plated Steel Handle Cover Polyvinyl e * ,F ,* . 150 9001 Sealing Element EPDM Registered L3 . Part No. Size(1) A(in) Al (in) L(in) L 1(in) L2(in) L3(in) i --r,-----. 7-7-Z7" �` 1 1 79840 11/2" 1.50 1.39 2.91 2.80 3.36 6.12 11111�110 79845 2" 1.77 1.83 3.35 3.41 3.68 6.12 A Al L L1 "Zero Lead identifies Viega products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372(0.25%or less maximum weighted average lead content). Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 5 of 16 Submittal viega 9 Package Viega Pro Press® Ball Valve - Zero Lead* Model 2971.4 ZL Description The Zero Lead bronze ball valve is 111111111111 .111. ZEROLEAD. equippedwith a full port,Zero Lead bronze body.The ball valve features EPDM .44‘ sealing elements, EPDM stem seals and Viega's Smart Connect@ feature for easy ; lam identification of unpressed connections during pressure testing. Features •316 Stainless Steel Ball • Eco Brass Blowout-proof Stem • Lockable Metal Handle • Reinforced PTFE Seats •Smart Connect Feature • Press x FPT connections Ratings Component Material •250 CWP Body Zero Lead Bronze C87700 •Temperature Range:0°F-250°F Ball 316 Stainless Steel • Max. Operating Pressure:250 psi Seat Reinforced PTFE Stem Eco Brass C69300 Approvals Stem Seals EPDM •Conforms to MSS SP-110 • NSF- UP Code Nut Zinc plated Steel • NSF 61 Annex G Handle Zinc plated Steel •ASME A112.4.14 Handle Cover Polyvinyl 1509001 •Listed by NSF to Commercial Hot Sealing Element EPDM Registered L2 Product Size A(in) Al (in) L(in) L 1(in) L2(in) H(in) Number 1 x FPT _ \v;��� 79970 1/2"x 1/" 0.73 0.66 1.57 1.20 4.57 1.97 _ 1� 79975 3/4"x 3/4" 0.85 0.79 1.75 1.35 4.57 2.09 1 I IIID��I�I�=�)-FPT 79980 1" x 1" 1.02 0.98 1.93 1.63 5.75 2.46 AA1 L ► L1 *Zero Lead identifies Viega©products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372(0.25%or less maximum weighted average lead content). Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 6 of 16 Submittal viega 9 Package Viega Pro Press® Ball Valve - Zero Lead* Model 2971.6 ZL Description The Zero Lead bronze ball valve is equipped with a full port,Zero Lead ZEROLEAD. bronze body.The ball valve features EPDM sealing elements, EPDM stem seals and Viega's Smart Connect®feature for easy identification of unpressed connections =-- ''• during pressure testing. s � ' Features tiF /I ' •316 Stainless Steel Ball • Eco Brass Blowout-proof Stem t . : i �'. L. • Lockable Metal Handle • • Reinforced PTFE Seats . • Smart Connect Feature • Press x garden hose connections •Hose cap is full pressure rated Component Material Ratings Body Zero Lead Bronze C87700 •250 CWP Ball 316 Stainless Steel •Temperature Range: 0°F-250°F Seat Reinforced PTFE • Max.Operating Pressure:250 psi Stem Eco Brass C69300 Approvals Stem Seals EPDM • Conforms to MSS SP-110 Nut Zinc plated Steel • NSF-UP Code Handle Zinc plated Steel • NSF 61 Annex G Handle Cover Polyvinyl iso 1 * , * . •ASME A112.4.14 Sealing Element EPDM Registered •Listed by NSF to Commercial Hot L2 Product Size A(in) L(in) L 1(in) L2(in) H(in) H .. ________....°`� y Number 1 x Hose Ir.---,-tAkV.__- .-.••, 79875 t/2"x 3/a" 0.75 1.57 1.35 4.57 1.97 1_.I�I I�I�II� IIIc 6_Hose 79876 3/4"x s/n" 0.85 1.75 1.35 4.57 2.09 III �I .- A L - L1 *Zero Lead identifies Viega°products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372 (0.25% or less maximum weighted average lead content). Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 7 of 16 Submittal viea 9 Package ProPress® Zero Lead* Bronze Check Valve Model 2974 ZL ZEROLEAD, Description •Zero Lead Bronze Body • ProPress Ends • Spring Check • EPDM Seals ► ' 410iali WaillinilliMill ti*O1 • 0.5 psi Cracking Pressure IIVe Features11, • Low Pressure Loss Nipm64. — - - j -- ' it. • Silent Operation • Stainless Steel Spring • Smart Connect,feature Pressure Drop Ratings 16 1/2I' 3,1" 1" 1.1/4" 1.1/2" 2" 14 •400 WOG • Max. Operating Pressure: 200 psi 12 •Temperature Range:0°F-200°F .N ,2- 10 2 Approvals o 8 i 11011111 • Conforms to MSS SP-80 d 5 • NSF-61 Annex G o_ 4 2 0 0 50 100 150 200 250 Flow Rate(gpm) 7 Part No d A (in) L (in) Wt (lbs) ...4". .._.. --...__ lailf,„„).„...,,77-1 JIIiiU1 I� d 79035 '/2" 0.872.520.17 79040 3/a" 1.14 2.95 0.28 79045 1" 1.34 3.15 0.42 A 79050 1t 1.69 3.74 0.60 79055 11/2" 2.09 4.92 0.96 L 79060 2" 2.56 5.71 1.87 `Zero Lead identifies Viega°products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372(0.25%or less maximum weighted average lead content). Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 8 of 16 Submittal viega 9 Package Viega ProPress® Ball Valve Model 2973 Description 1l J Viega ProPress model 2973 is a full port ball valve intended for hydronic and non-potable applications.The ball valve 4,-'--*, features EPDM sealing elements, EPDM - _ f stem seals and Viega's Smart Connect® feature for easy identification of unpressed .m."17 connections during pressure testing. "`'+' .. _......F. #�yy �'�IM/ r 7 '� 1,..1 • /iir �. Features �'"+ir se •Chrome-plated brass ball i'w' 1 . • Blowout-proof stem • Reinforced PTFE seats •Smart Connect feature • ProPress connections Ratings Component Material •250 CWP Body Brass C37700 •Temperature range:0°F-250°F Ball Chrome-plated Brass • Max. operating pressure:200 psi Seat Reinforced PTFE Stem Brass C37700 Approvals •Conforms to MSS SP-110 Stem Seals EPDM • NSF-U.P.Code Nut Zinc-plated Steel • IGC-157 Handle Zinc-plated Steel e Handle Cover Polyvinyl � 150 9001 Sealing Element EPDM Registered L2 Part Number 1 A(in) Al (in) L(in) L 1(in) L2(in) H(in) H -47--- •'�� 24000 /z" 0.83 0.83 1.58 1.58 3.94 1.69 -'• s4 24005 3/a" 0.95 0.95 1.86 1.86 4.72 1.97 3111111111111 1 24010 1" 1.18 1.18 2.09 2.09 4.72 2.13 24015 11/4" 1.29 1.29 2.31 2.31 6.22 2.87 A Al 24020 11/2" 1.39 1.39 2.81 2.81 6.22 3.11 L L1 24025 2" 1.85 1.85 3.43 3.43 6.22 3.46 NOTE:Model 2973 is for use in non-potable applications. For NSF-61G compliant valves refer to Viega ProPress models 2971.1ZL and 2971.3ZL Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 9 of 16 Submittal viega 9 Package Viega ProPress® Ball Valve Model 2973.1 Description al Viega ProPress model 2973.1 is a full port ball valve intended for hydronic and non-potable applications.The ball valve features EPDM sealing elements, EPDM stem seals and Viega's Smart Connect® feature for easy identification of unpressed connections during pressure testing. ir . Features / rye_ • •Chrome-plated brass ball • fah% T • Blowout-proof stem i • Reinforced PTFE seats •Smart Connect feature I', • Press x FPT connections Ratings •250 CWP •Temperature range:0°F-250°F Component Material • Max. operating pressure:200 psi Body Brass C37700 Ball Chrome-plated Brass Approvals Seat Reinforced PTFE •Conforms to MSS SP-110 Stem Brass C37700 • NSF-U.P.Code Stem Seals EPDM • IGC-157 Nut Zinc-plated Steel Handle Zinc-plated Steel Handle Cover Polyvinyl �� * ,F ,* . Is 9001 Sealing Element EPDM Registered L2 ► 7' • � Part Number 1 x FPT A(in) Al (in) L(in) L 1(in) L2(in) H(in) 1 0110111111111 f-- 24030 1"x 1" 0.83 0.63 1.58 1.16 3.94 1.69 1 � -FPT 24035 3/a"x 3/a" 0.95 0.71 1.86 1.26 4.72 1.97 "., 1,1:4.16124040 1" x 1" 1.18 0.93 2.09 1.59 4.72 2.13 A-+-A1 L L1 NOTE:Model 2973 is for use in non-potable applications. For NSF-61G compliant valves refer to Viega ProPress model 2971.4ZL. Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 10 of 16 Submittal viega 9 Package Viega ProPress® Ball Valve Model 2973.3 Description Viega ProPress model 2973.3 is a full 1' port ball valve intended for hydronic and 4111111111111111111141 non-potable applications.The ball valve features EPDM sealing elements, EPDM, stem seals and Viega's Smart Connect& ••r.,, rg-N... feature for easy identification of unpressed f connections during pressure testing. 4 Imp, i.- Features dilrti / / ,. •Chrome-plated brass ball • ., • Blowout proof stem . , f 'if _4 • Reinforced PTFE seats •Smart Connect feature � �� • Press x garden hose connections •Hose cap is full pressure rated Ratings •250 CWP Component Material •Temperature range:0°F-250°F Body Brass C37700 • Max. operating pressure: 200 psi Ball Chrome-plated Brass Seat Reinforced PTFE Approvals Stem Brass C37700 •Conforms to MSS SP-110 Stem Seals EPDM • NSF-U.P. Code Nut Zinc-plated Steel • IGC-157 Handle Zinc-plated Steel Handle Cover Polyvinyl e * * : I50 9001 nccREnlreo Sealing Element EPDM Registered L2 1 !:_ Part Number 1 x Hose A(in) Al (in) L(in) L 1(in) L2(in) H(in) I[I111[1111110111.11 I 11 l 1 Hose 24090 '/"x 3/4" 0.83 0.85 1.58 1.30 3.89 1.67 II IIIIII��!� _ —� - ,� __�-=�--.., 24095 3/4"x 3/4" 0.95 0.95 1.86 1.39 4.72 1.97 AA1 L L1 NOTE:Model 2973 is for use in non-potable applications. For NSF-61G compliant valves refer to Viega ProPress model 2971.6ZL. Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 11 of 16 Submittal viega 9 Package ProPress® 316 Stainless Ball Valve Model 4070 Description Viega's ProPress 316 stainless steel ball valve can be used in a variety of commercial and industrial applications.The EPDM sealing elements make it the perfect choice for potable water systems while the durable 316 stainless steel allows it to stand up to some of the harshest environments found in power plants, gig refineries, utilities,and mills.The double EPDM stem seals / / / prevent leaks without the need for constant adjustment.The 316 i stainless steel ball valves are available in sizes ranging from'h" ° to 2' and are equippedwith Viega's patented Smart Connect ,k feature for easy identification of unpressed connections during �► / pressure testing. -411 �y Features # • ProPress press ends • 316 Stainless Steel ball and stem • Full port,two piece design • Blowout-proof stainless steel stem • Reinforced PTFE seats Component Material • Lockable metal handle Body 316 Stainless Steel Ratings Ball 316 Stainless Steel • 250 CWP Seat Reinforced PTFE • Temperature Range:0°F to 250°F • Max.operating pressure:200 psi Stem 316 Stainless Steel Stem Seals EPDM Approvals • Conforms to MSS SP-110 Nut Zinc plated Steel • NSF-61 Annex G Handle Zinc plated Steel e • NSF-372 Handle Cover Polyvinyl 1509001 *,., ,*, Sealing Element EPDM Registered L2 Stock Code Size(1) A(in) Al (in) L(in) L 1(in) L2(in) H(in) H _ " 81080 '/2" 0.89 1.17 1.64 1.92 5.55 2.44 `` ,1 81085 3/a" 1.06 1.36 1.97 2.26 5.55 2.52 1 P1111111011 1810901" 1.181.572.09 2.48 5.55 2.68 81095 1Ya" 1.45 1.72 2.48 2.75 6.10 3.09 - 81100 11/2" 1.83 1.81 3.26 3.24 6.10 3.34 A Al 81105 2" 1.97 2.18 3.54 3.78 6.10 3.66 L L1 Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 12 of 16 Submittal viega 9 Package ProPress 3-Piece Stainless Steel Ball Valve Model 4370.8 Description The ProPress®3-Piece Stainless Steel ball valve is equipped with a full port,316 stainless steel 3-piece body.The ball valvelikalliffaiitalb features FKM sealing elements, PTFE stem seals, lockable metal handle and Viega's Smart i....-! Connect®feature for easy identification of unpressed connections during pressure testing. (*, II � '''''''.. 111111111."1I ' Features i • 316 stainless steel ball �' i R � �� Floils ` III • Blowout-proof 316 stainless steel stem • 304 stainless steel locking handle k el- • Adjustable packing nut • Reinforced PTFE seats • Smart Connect feature • ISO 5211 mounting pad ®. i6 Ratings iso 9001 M:CNEUeED Registered • 250 CWP • Max. operating pressure: 200 psi • Temperature range: 0°F to 250°F VALVE Valve Body Bolt Torque Valve Stem Stem Nut SIZE Bolt&Nut Size +/-5 Nut Size Approvals ft/lbs (Nm) ft/lbs (Nm) • Conforms to MSS SP-110 1/2"■' M8 x 45 M8 7.5 (10) AF 16 mm 7.5 10 3/4" M8 x 56 M8 7.5 (10) AF 18 mm 7.5 10 1" ■' M8 x 65 M8 15 (20) AF 21 mm 11 15 11/4" M10 x 75 M10 15 (20) AF 22 mm 11 15 11/" M10 x 90 M10 22.5 (30) AF 24 mm 18.5 25 2" M10 x 100 M10 22.5 (30) AF 24 mm 18.5 25 14 G + Part No. d B(in) C(in) D(in) Weight(lbs) 85132 1/2" 5.41 3.99 2.28 1.59 al D 85133- 3/4" 5.79 5.88 2.85 1.96 !�-1 _ la I 85134 1" 6.00 5.88 2.93 2.82 • / uIIi.i 11.11 85136• 11/4" 6.61 7.54 3.27 3.71 'e_ .r g'l ' I 85137 11/" 7.26 7.54 3.57 5.30 85138 2" 9.67 7.54 3.89 7.78 Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 13 of 16 Submittal viega 9 Package - Valve Accessories by Model Model 2971.8 Model 2971.96 Ball Valve Lockable Metal Handle Ball Valve Stem Extension Kit *Use with Models 2971ZL `Use with Models 2971ZL Are Illi P Part Number Size Part Number Size 22170 1/2,,&34" 23443 z"&3/a" green . 22172 1'&1A' 23445 1" &11/4" ii 23447 11/2"&2" Model 2973.8 Model 2973.96 Ball Valve Metal Handle Ball Valve Stem Extension Kit *Use with Models 2973 *Use with Models 2973 .z ® Part Number Size 22176 '/z" 22178 3/"&1" red 22180 11/4"&2" 3 Part Number Size 234491/2" 23451 /a &1" i 23453 11/4"to 2" Model 2970.8 Model 2970.96 Ball Valve Lockable Metal Handle Ball Valve Stem Extension Kit *Use with Model 4070 and 2970ZL `Use with Model 4070 and 2970ZL 4re ,40 /9 Part Number Size j Part Number Size 22143 1/2",3/4",1" — 23442 1/2",3/4" 1" gray "-N40122163 11/4", 11/2" 2" 23444 11/4",, 11/2",2" e get Model 2959.7 Flange Bolt Set "Use with Model 2873.81 - w I," Part Number Size 1°.!/'P ' ) 19748 1", 11/4", 11" W44 \\\U. 19758 2",21/2',3" 19763 4" Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 14 of 16 Submittal viega 9 Package Viega ProPress° Ball Valves For Types K, L and M Hard Copper Tubing in 1/2" to 2" and Soft Copper Tubing in 1/2" to 11/4" A WARNING Read and understand all instructions °"' \, �N� for installing Viega ProPress fittings. Failure to follow all -c-A , ;' iinstructions may result in extensive property damage, serious injury or death. I;;i///r/ � ; , 1,A 1.Cut copper tubing at right angles using displacement lb type cutter or fine-toothed steel saw. �1: 1 2 3 2.Remove burr from inside and outside of tubing to prevent cutting sealing element. 3.Check seal for correct fit. Do not use oils or lubricants. �� Use only Viega ProPress Shiny Black EPDM or Dull att'- �iNON, Black FKM sealingelements. lir -r �( •a',� ii Note: For applications req uiringViega ProPress with FKM �"r " o*Ape sealing elements,remove the factory-installed EPDM E . ( sealing element and replace with FKM sealing element. 4. Mark proper insertion depth as indicated by the Viega 4 5 6 ProPress Insertion Depth Chart. Improper insertion V �� depth may result in improper seal. -a_. ;,=�' �4_, �,� 5.While turning slightly, slide ball valve onto tubing to the `�t���, ,___,.....4,1s, marked depth. .,,,., �r "Z" Note: End of tubing must contact stop. �- �. I� :ea— r �a0 ., os i �r 6. Insert appropriate Viega jaw into the pressing tool and push in, holding pin until it locks in place. y t .0, 7.Open the jaw and place at right angles on the valve. CI 7 8 9 Visually check insertion depth using mark on tubing. 8.Start pressing process and hold the trigger until the jaw has engaged the valve. ProPress Insertion Depth Chart 9.After pressing, the jaw can be opened again. Tube Size 1/2" 3/a" 1" 11/4" 11" 2" Note: Only ball valves marked with NSF-61G are allowed for Insertion Depth 3/4" 1/8" 1/8" 1" 17A6" 19A6" use in potable water systems. Leak Testing with Smart Connect®: ��,� Unpressed connections are located by = pressurizing the system with air or water. When testing with water the proper pressure range is 15 psi to 85 psi maximum. Leak testing with air can be dangerous at high pressures. When testing with compressed air the proper pressure range is 1/2 psi to 45 psi maximum. Following a successful leak test,the system may be pressure tested up to 200 psi with air,or up to 600 psi with water,if required by local code requirements or project specifications. Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 15 of 16 Submittal viega 9 Package VIEGA LIMITED WARRANTY PROPRESS° FITTINGS AND VALVES Subject to the conditions and limitations in this Limited should be kept and Viega contacted by writing to the Warranty, Viega LLC (VIEGA) warrants to wholesalers address below or telephoning 1-800-976-9819 within and licensed plumbing and mechanical contractors thirty(30)days after the leak or other failure and in the United States and Canada that its PROPRESS identifying yourself as having a warranty claim. You fittings, when properly installed in non industrial and should be prepared to ship,at your expense, the product non marine applications and under normal conditions which you claim failed due to a manufacturing defect and of use, will be free of failure from manufacturing defect document the date of installation. Within a reasonable for a period of fifty (50)years from date of installation time after receiving the product,Viega will investigate the and that its PROPRESS valves,when properly installed reasons for the failure,which includes the right to inspect in non industrial and non marine applications and under the product at Viega.Viega will notify you in writing of the normal conditions of use, will be free of failure from results of its review. manufacturing defect for a period of two (2)years from date of installation. In the event that Viega determines that the failure or leak was the result of a manufacturing defect in the part Under this Limited Warranty, you only have a right to a covered by this warranty and that this warranty applies, remedy if the failure or leak resulted from a manufacturing the EXCLUSIVE AND ONLY REMEDY under this warranty defect in the products covered by this warranty and the shall be the reimbursement for repair and/or replacement failure or leak occurred during the warranty period.You do of the part.VIEGA SHALL NOT BE LIABLE FOR ANY not have a remedy under this warranty and the warranty CONSEQUENTIAL OR OTHER DAMAGE (FOR EXAMPLE, does not apply if the failure or any resulting damage is WATER OR PROPERTY OR MOLD REMEDIATION) caused by (1) components other than those manufactured UNDER ANY LEGAL THEORY AND WHETHER or sold by Viega; (2) not designing, installing, inspecting, ASSERTED BY DIRECT ACTION, FOR CONTRIBUTION or testing the ProPress fittings or valves in accordance OR INDEMNITY OR OTHERWISE. with Viega's installation instructions in effect at the time of the installation; applicable code requirements; and THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER accepted industry practice; (3) improper handling and WARRANTIES, EXPRESS OR IMPLIED, INCLUDING protection of the product prior to and during installation, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF inadequatefreeze protection, exposure to water pressures MERCHANTABILITY AND FITNESS FOR A PARTICULAR or temperatures or in applications outside acceptable PURPOSE. If a limited warranty shall be found to apply, operating conditions; (4)acts of nature such as, but not such warranty is limited to four years. Other than this limited to,earthquakes, fire, flood, or lightning, or (5) Limited Warranty, Viega does not authorize any person external environmental causes, such as water quality or firm to create for it any other obligation or liability in variations, aggressive water, or other external chemical or connection with its products. physical conditions. This Limited Warranty gives you specific legal rights and In the event of a leak or other failure of the parts covered you also may have other rights which may vary from state by this warranty, it is the responsibility of the property to state.This warranty shall be interpreted and applied owner to obtain and pay for repairs. Only if the warranty under the law of the state in which the product is installed applies will Viega be responsible for the remedy under and is intended as a Commercial Warranty. this warranty. The part or parts which you claim failed Viega products are designed to be installed by licensed and trained plumbing and mechanical professionals who are familiar with our products'proper use and installation.Installation by non-professionals may void Viega LLC's warranty. This document subject to updates.For the most current Viega technical literature please visit www.viega.us. Click Services->Click Electronic Literature Downloads->Select Product Line->Select Desired Document Viega LLC,12303 Airport Way,Ste.395• Broomfield, CO 80021• Ph:800-976-9819 • Fax:800-976-9817 SM-PP 1116(Ball Valves) 16 of 16