F18-0074_Approved Documents_1543262475.pdf
75 South Frontage Road Fire -Construction Permit West, TOWN OF VAIL F18-0074 Vail, CO 81657 Issued: 11/26/2018 TOWN of VAILOFOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 715 W LIONSHEAD CIR(210107217001)(210107217001) Unit#: P a r c e IN u tuber: 210107217001 LegalDescription: Subdivision:WEST DAYSUBDIVISION Lot: 1 R908760 MAP 03-10-05 R910219 BSD 03-24-05 R920513 EAS 06-24-05 R200625646 EAS 09-20-06 R200715212 EAS 06-11-07 R200719892EAS 07-27-07 Contacts ContactType: Applicant Full Name: PeterMazen Address: 274 CenterDrive Glenwood Springs,CO 81601 Phone: 3037920022 ContactType: PropertyOwner FuIlName: DIAMONDROCKVAIL OWNERLLC DIAMONDROCKHOSPITALITYCO Address: Phone: None Contractor Contractor Type: Fire Protection Company: WesternStates Fire ProtectionCo. State License#: Phone: 303-549-8975 Projectlnformation ProjeciName: Vail MarriottRenovation2018 ProjeciDescription: Relocate 87 sprinklers to adapt to new wall and ceiling location. Fees Paid Account#:001-0000.31111.00-Fire SuppressionPermitFee Fee Amount: $2,588.25 Account#:001-0000.31123.00 Fire SuppressionReviewFee Fee Amount: $432.00 TotalPaid: $3,020.25 Conditions Issued By: Town ofVailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicantagrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law. Failure to do so will void this Permitand the applicantshall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # F 18-0074 Date Printed: 11/20/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0074 Status: Created Permit Number: Date Started: 11/19/2018 Permit Type: Fire-Construction Permit Subc ases Fire Suppression Lot Number: Property: 715 W LI ONSHEAD CI R(210107217001)(210107217001) Contacts Contact Type: Applicant Company Name: Western States Fire Protection Full Name: Peter Mazen Address: 274 Center Drive Glenwood Springs,CO 81601 Email: peter.mazen@wsfp.us Contact Type: Property Owner Full Name: DIAMONDROCKVAI L OWNER LLC DIAMOND Address: Permit Fees Fee Information Account Amount Fire Suppression Permit Fee 001-0000.31111.00 $2,588.25 Fire Suppression Review Fee 001-0000.31123.00 $432.00 Payment Information Date Paid Payment Type Amount Fire Suppression Permit Fee 11/20/2018 Check $2,588.25 Paid By:Carolyn Godfrey-Notes:ck#124577 Western States Fire Protection Fire Suppression Review Fee 11/20/2018 Check $432.00 Paid By:Carolyn Godfrey-Notes:ck#124577 Western States Fire Protection FEE TOTAL $3,020.25 AMOUNT PAID $3,020.25 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 11/20/2018-2:24:49 PM-Generated by:cgodfrey 1/1 6 Western States Fire Protection Co. Protectift9 .Elim aid promo FIRE PROTECTION SYSTEM Hydraulic Calculation and Material Submittal Vail Marriott Level2 East Revisions 715 W Lionshead Circle Vail, CO 81657 Thomas M.Coakley,CET Western States Fire Protection Co. NICET Level III Registration#107852 Sprinkler Systemys�Layout Signa ZIO Prepared by: PeterMazen Project Manager Western StatesFire Protection Co. 7026 S. Tucson Way Centennial,CO 80112 Phone(303)-792-0022 Fax(303)792-9049 WSFP#CS3036 November 13, 2018 Hydraulic Overview \ Job Number:CS3036 Report Description:Light Hazard-CALC#1 Job Number Circuit Description CS3036 Peter Mazen Job Name: Phone FAX VAIL MARRIOTT LVL 2 EAST 530-518-4299 Address 1 Stale Certification/License Number 715 W LIONSHEAD CIR Address 2 AHJ VAIL,CO 81657 Address 3 Part Description Density Area of Application 0.10gpm/ft2 1500ft2(Actual 971W) Most Demanding SprinklerData Hose Streams 5.6 K-Factor 19.60 at 12.250 100.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 196ft2 13 System Pressure Demand system Flow Demand 103.671 328.13 Total Demand Pressure Result 428.13 @ 103.671 +37.989(26.8%) Supplies Check Point Gauges art Numb( Name Flow(gpm) Hose Flow(gpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(gpm) 1 Water Supply 1210.00 100.00 150.000 93.000 CS3036-Vail Marriott Phase 2 Submittal Drawings. Water Supply at Node 1 (1210.00, 0.00,150.000, 93.000) 200 180 • — B.a ISI 1 160 f I Static Pressure 150.000 140 _ 120 \• 328.13 103.671 100LuuwtnhIuhiwIHuhIIIHHIIIIrIIIIIIIIIIIpI I 210.00 @ 93.000 28.13 with hose streams o_ 80 60 stem demand rve 40 20 0 1111111 111111111 0075Q10001250 1500 1750 2000 2250 2500 Water flow,gpm ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:08PM Page 1 Hydraulic Graph Job Number:CS3036 Report Description:Light Hazard-CALC#1 Water Supply at Node 1 200 180 160 Static Pressure 150.000 140 - 120 — 328.13 @ 103.671 1 2 100 I 428.13 with hose streams 1210.00 @ 93.000 a 80 60 System demand curve 40 20 0 —miniiiiiiiiiiiiii iiiiiiiii 111111111 111111111 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i i 1 1 1 1 1 1 1 250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Hydraulic Graph Water Supply at Node 1 S tatiorressure 150.000 Residual:Pressure 93.000 @ 1210.00 Available Pressure at Time of Test 141.661 @ 428.13 s vaenoemana 103.671 @ 328.13 S ystenDemand(Including Hose Allowance at Source) 103.671 @ 428.13 �4 ©M.E.P.CAD,Inc. i AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:12PM Page 2 i Summary Of Outflowing Devices I Job Number:CS 3036 5• - Report Description:LightHazard-CALC#1 Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) 4, Sprink ler 517 19.60 19.60 5.6 12.250 Sprinkler 518 19.89 19.60 5.6 12.620 Sprinkler 519 22.28 19.60 5.6 15.831 Sprinkler 529 20.23 19.60 5.6 13.057 Sprinkler 530 21.13 19.60 5.6 14.242 Sprinkler 531 23.44 19.60 5.6 17.513 Sprinkler 539 23.01 19.60 5.6 16.879 Sprinkler 540 23.58 19.60 5.6 17.730 Sprinkler 541 26.46 19.60 5.6 22.328 Sprinkler 556 40.49 19.60 5.6 52.275 Sprinkler 557 29.64 19.60 5.6 28.013 Sprinkler 558 33.71 19.60 5.6 36.230 Sprinkler 640 24.66 19.60 5.6 19.396 ♦ Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:21PM Page 3 iii Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 DR 1.0490 19.60 7.28 120 0.125357 15'-4 Pf 2.677 517 9'-5 19.60 5.6 12.250 Sprinkler, 6'-0 Pe -0.903 119 11'-6 14.024 3E(2'-0) 21'-4 Pv BL 1.0490 39.83 14.79 120 0.465550 8'-0 Pf 3.724 119 11'-6 20.23 14.024 Flow(q)from Route 3 Pe 158 11'-6 17.748 8'-0 Pv BL 1.0490 62.84 23.33 120 1.082035 3'-0 Pf 3.240 158 11'-6 23.01 17.748 Flow(q)from Route 6 Pe 209 11.-6 20.988 3'-0 Pv BL 1.0490 87.50 32.48 120 1.996349 5'-7 Pf 11.180 209 11'-6 24.66 20.988 Flow(q)from Route 9 Pe 251 11'-6 32.168 5'-7 Pv BL 1.4420 117.14 23.01 120 0.727150 32'-2 Pf 28.774 251 11'-6 29.64 32.168 Flow(q)from Route 11 7'-5 Pe 379 11'-6 60.941 PO(T-5) 39'-7 Pv CM 3.2600 287.64 11.06 120 0.072135 6'-10 Pf 0.492 379 11'-6 170.49 60.941 Flow(q)from Route 2 Pe 378 11'-6 61.433 6'-10 Pv CM 3.2600 328.13 12.61 120 0.092036 47'-9 Pf 8.103 378 11'-6 40.49 61.433 Flow(q)from Route 13 40'-4 Pe 354 11'-6 69.536 2T(20'-2) 88'-1 Pv CM 4.2600 328.13 7.39 120 0.025009 130'-4 Pf 19.488 354 11'-6 69.536 226'-6 Pe 10.694 12 -13'-2 99.718 2f(-0.000),BV(15'-10),16E(13'- 356'-10 Pv 2),BFP(-9.348),PRV(-1.216) UG 4.2200 328.13 7.53 140 0.019688 57'-3 Pf 1.786 12 -15-2 99.718 35-5 Pe 11 -13'-2 101.504 T(33'-5) 90'-9 Pv UG 6.2800 328.13 3.40 140 0.002841 719'-0 Pf 2.168 11 -13'-2 101.504 44'-2 Pe 1 -13'-2 103.671 4EE(11'-0),S 763'-1 Pv 100.00 Hose AllowanceAt Source 1 428.13 Route 2 DR 1.0490 19.89 7.39 120 0.128860 17'-9 Pf 3.700 518 9'-5 19.89 5.6 12.620 Sprinkler, 11'-0 Pe -0.903 125 11'-6 15.417 3E(2'-0),T(5'-0) 28'-9 Pv BL 1.0490 41.03 15.23 120 0.491665 10'-0 Pf 4.913 125 11'-6 21.13 15.417 Flow(q)fromRoute4 Pe 197 11.-6 20.330 10'-0 Pv BL 1.0490 64.61 23.98 120 1.138931 12'-11 Pf 19.301 197 11'-6 23.58 20.330 Flow(q)from Route 8 4'-0 Pe 255 11'-6 39.632 2E(2'-0) 16'-11 Pv BL 1.4420 98.31 19.31 120 0.525817 32'-2 Pf 20.807 255 11'-6 33.71 39.632 Flow(q)from Route 12 7'-5 Pe 380 11'-6 60.438 P0(7-5) 39'-7 Pv CM 3.2600 170.49 6.55 120 0.027412 18'-4 Pf 0.503 380 11'-6 72.18 60.438 Flow(q)from Route 5 Pe 379 11'-6 60.941 18'-4 Pv Route 3 DR 1.0490 20.23 7.51 120 0.132974 5-1 Pf 1.871 529 9'-5 20.23 5.6 13.057 Sprinkler, 9'-0 Pe -0.903 119 11'-6 14.024 2E(2'-0),T(5'-0) 14'-1 Pv Route 4 DR 1.0490 21.13 7.85 120 0.144104 5'-5 Pf 2.078 530 9'-5 21.13 5.6 14.242 Sprinkler, 9'-0 Pe -0.903 125 11'-6 15.417 2E(2'-0),C(5'-0) 14'-5 Pv - Route 5 _ DR 1.0490 22.28 8.27 120 0.158916 18'-9 Pf 4.722 519 9'-5 22.28 5.6 15.831 Sprinkler, 11'-0 Pe -0.903 127 11'-6 19.650 3E(2'-0),T(5'-0) 29'-9 Pv BL 1.0490 45.72 16.97 120 0.600632 8'-0 Pf 4.805 127 11'-6 23.44 19.650 Flow(q)from Route 7 Pe 164 11'-6 24.455 8'-0 Pv ©M.E.P.CAD,Inc. NUAutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:25PM Page 4 b�ii Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length BL 1.0490 72.18 26.79 120 1.398058 13'-4 Pf 24.196 164 11'-6 26.46 24.455 Flow(q)from Route 10 4'-0 Pe 259 11'-6 48.651 2E(2'-0) 17'-4 Pv BL 1.4420 72.18 14.18 120 0.296853 32'-2 Pf 11.747 259 11'-6 48.651 7'-5 Pe 381 11'-6 60.397 PO(7-5) 39'-7 Pv CM 3.2600 72.18 2.77 120 0.005589 7'-4 Pf 0.041 381 11.-6 60.397 Pe 380 11'-6 60.438 7'-4 Pv OF Route 6 DR 1.0490 23.01 8.54 120 0.168626 3'-6 Pf 1.772 539 9'-5 23.01 5.6 16.879 Sprinkler, 7'-0 Pe -0.903 158 11'-6 17.748 E(2'-0),T(5'-0) 10'-6 Pv Route 7 DR 1.0490 23.44 8.70 120 0.174472 8'-5 Pf 3.040 531 9'-5 23.44 5.6 17.513 Sprinkler, 9'-0 Pe -0.903 127 11'-6 19.650 2E(2'-0),T(5'-0) 17'-5 Pv - Route 8 DR 1.0490 23.58 8.75 120 0.176469 5'-10 Pf 3.504 540 9'-5 23.58 5.6 17.730 Sprinkler, 14'-0 Pe -0.903 197 11'-6 20.330 2E(2'-0),2T(5'-0) 19'-10 Pv OF Route 9 DR 1.0490 24.66 9.16 120 0.191757 6'-0 Pf 2.495 640 9'-5 24.66 5.6 19.396 Sprinkler, 7'-0 Pe -0.903 209 11'-6 20.988 E(2'-0),T(5'-0) 13'-0 Pv Route 10 DR 1.0490 26.46 9.82 120 0.218433 6'-10 Pf 3.029 541 9'-5 26.46 5.6 22.328 Sprinkler, 7'-0 Pe -0.903 164 11'-6 24.455 E(2'-0),T(5'-0) 13'-10 Pv - Route 11 DR 1.0490 29.64 11.00 120 0.269417 9'-3 Pf 4.372 557 11'-0 29.64 5.6 28.013 Sprinkler, 7'-0 Pe -0.217 251 11'-6 32.168 E(2'-0),T(5'-0) 16-3 Pv Route 12 DR 1.0490 33.71 12.51 120 0.341793 3'-7 Pf 3.618 558 11'-0 33.71 5.6 36.230 Sprinkler, 7'-0 Pe -0.217 255 11'-6 39.632 E(2'-0),T(5'-0) 10'-7 Pv - Route 13 DR 1.0490 40.49 15.03 120 0.479788 4'-2 Pf 5.343 556 11'-0 40.49 5.6 52.275 Sprinkler, 7'-0 Pe -0.217 247 11'-6 57.402 E(2'-0),T(5'-0) 11'-2 Pv BL 1.4420 40.49 7.95 120 0.101874 32'-2 Pf 4.031 247 11.-6 57.402 7'-5 Pe 378 11'-6 61.433 P0(7.-5) 39'-7 Pv Equivalent Pipe Lengths of Valvesand Fittings(C=120 only) wiMI C Value Multiplier -11 Actual Inside Diameter 4.87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD,Inc. ,111 AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:25PM Page 5 Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary _ Upstream Total Length Pipe Type Legend Units Legend EMMEp 111 Fittings Legend i AO Arm-Over Diameter Inch ALV AlarmValve BL Branch Line Elevation Foot AngV Angle Valve CM Cross MainFlow gpm b Bushing DN Drain BaIV Ball Valve DR Drop Discharge gpm BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous FrictionLoss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple DeIV Deluge Valve Pt Totalpressure at a point in a pipe SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90°Elbow UG Underground Pf Pressure loss due to friction between points EE 45°Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 22W Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. ,111 AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:25PM Page 6 NilHydraulic Overview \ Job Number:CS3036 Report Description:Light Hazard-CALC#2 Job Number Circuit Description CS3036 Peter Mazen Job Name: Phone FAX VAIL MARRIOTT LVL 2 EAST 530-518-4299 Address 1 State Certification/License Number 715 W LIONSHEAD CIR Address 2 AHJ VAIL,CO 81657 Address 3 Part Description Density Area of Application 0.10gpm/ft2 1500ft2(Actual 1084ft') Most Demanding SprinklerData Hose Streams 5.6 K-Factor 22.50 at 16.143 100.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 225ft2 8 System Pressure Demand system Flow Demand 82.578 207.18 Total Demand Pressure Result 307.18 @ 82.578 +62.910(43.2%) Supplies Check Point Gauges art Numb( Name Flow(gpm) Hose Flow(gpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(gpm) 1 Water Supply 1210.00 100.00 150.000 93.000 CS3036-Vail Marriott Phase 2 Submittal Drawings. Water Supply at Node 1 (1210.00, 0.00,150.000, 93.000) 200 180 Ir 160 Static Pressure 150.000 Ell I` 140 •_ 120 N 100 1210.00 @ 93.000 N 80 a •= 307.18 with hose streams 60 System demand curve 40 20 0 allllllllal�lllll lllllllll IIIIIIIII IIIIIIIII 111111111 111111111 1111111 111111111 5h.?)007501000 1250 1500 1750 2000 2250 2500 Water flow,gpm ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:53PM Page 1 Hydraulic Graph Job Number:CS3036 Report Description:Light Hazard-CALC#2 Water Supply at Node 1 200 180 160 Static Pressure 150.000 140 120 N Q 100 1210.00 @ 93.000 a 207.18 @ 82.578 1 80 307.18 with hose streams 60 System demand curve 40 20 0 —.L111111111 111111111 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i 1 1 1 1 1 1 1 1 1 I 1 1 1 i i 1 1 250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Hydraulic Graph Water Supply at Node 1 S tatiorressure 150.000 Residual:Pressure 93.000 @ 1210.00 Available Pressure at Time of Test 145.488 @ 307.18 s vaenoemana 82.578 @ 207.18 S ystenDemand(Including Hose Allowance at Source) 82.578 @ 307.18 �4 ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:57PM Page 2 i Summary Of Outflowing Devices I Job Number:CS 3036 5• - Report Description:Light Hazard-CALC#2 Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) Sprinkler 583 28.05 22.50 5.6 25.085 Sprinkler 584 30.29 22.50 5.6 29.265 Sprinkler 588 26.96 22.50 5.6 23.178 Sprinkler 589 28.29 22.50 5.6 25.520 Sprinkler 593 24.45 22.50 5.6 19.063 Sprinkler 594 23.65 22.50 5.6 17.837 Sprinkler 598 22.98 22.50 5.6 16.844 * Sprinkler 599 22.50 22.50 5.6 16.143 ♦ Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:28:06PM Page 3 iii Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 DR 1.0490 22.50 8.35 120 0.161813 14'-6 Pf 2.670 599 11'-0 22.50 5.6 16.143 Sprinkler, 2'-0 Pe -0.217 478 11'-6 18.596 E(2'-0) 16'-6 Pv BL 1.0490 46.15 17.13 120 0.611240 13'-0 Pf 7.934 478 11'-6 23.65 18.596 Flow(q)from Route 3 Pe 459 11'-6 26.531 13'-0 Pv BL 1.4420 46.15 9.07 120 0.129786 1'-0 Pf 0.132 459 11'-6 26.531 Pe 449 11'-6 26.663 1'-0 Pv BL 1.4420 74.44 14.62 120 0.314299 12'-6 Pf 3.929 449 11'-6 28.29 26.663 Flow(q)from Route 7 Pe 433 11'-6 30.592 12'-6 Pv BL 1.4420 104.74 20.58 120 0.591107 34'-7 Pf 24.834 433 11'-6 30.29 30.592 Flow(q)from Route 8 7'-5 Pe 368 11'-6 55.426 P0(7'-5) 42'-0 Pv CM 3.2600 207.18 7.96 120 0.039311 28'-10 Pf 2.720 368 11'-6 102.44 55.426 Flow(q)from Route 2 40'-4 Pe 354 11'-6 58.146 2T(20'-2) 69'-2 Pv CM 4.2600 207.18 4.66 120 0.010682 130'-4 Pf 12.049 354 11'-6 58.146 226'-6 Pe 10.694 12 -13'-2 80.889 2f(-0.000),BV(15'-10),16E(13'- 356'-10 Pv 2),BFP(-8.061),PRV(-0.177) UG 4.2200 207.18 4.75 140 0.008409 57'-3 Pf 0.763 12 -13'-2 80.889 33'-5 Pe 11 -13'-2 81.652 T(33'-5) 90'-9 Pv UG 6.2800 207.18 2.15 140 0.001213 719'-0 Pf 0.926 11 -13'-2 81.652 44'-2 Pe 1 -13'-2 82.578 4EE(11'-0),S 763'-1 Pv 100.00 Hose AllowanceAt Source 1 307.18 Route 2 DR 1.0490 22.98 8.53 120 0.168300 20'-10 Pf 5.021 598 11'-0 22.98 5.6 16.844 Sprinkler, 9'-0 Pe -0.217 468 11'-6 21.648 2E(2'-0),T(5'-0) 29'-10 Pv BL 1.0490 47.43 17.61 120 0.643036 6'-0 Pf 3.854 468 11'-6 24.45 21.648 Flow(q)fromRoute4 Pe 464 11'-6 25.502 6'-0 Pv BL 1.4420 47.43 9.32 120 0.136537 6'-0 Pf 0.818 464 11'-6 25.502 Pe 456 11'-6 26.320 6'-0 Pv BL 1.4420 74.39 14.61 120 0.313931 10'-0 Pf 3.137 456 11'-6 26.96 26.320 Flow(q)from Route 5 Pe 439 11'-6 29.457 10'-0 Pv BL 1.4420 102.44 20.12 120 0.567375 38'-1 Pf 25.838 439 11'-6 28.05 29.457 Flow(q)from Route 6 7'-5 Pe 366 11'-6 55.295 P0(7'-5) 45'-6 Pv CM 3.2600 102.44 3.94 120 0.010682 12'-3 Pf 0.131 366 11'-6 55.295 Pe 368 11'-6 55.426 12'-3 Pv Route 3 DR 1.0490 23.65 8.78 120 0.177459 0'-6 Pf 0.976 594 11'-0 23.65 5.6 17.837 Sprinkler, 5'-0 Pe -0.217 478 11'-6 18.596 T(5'-0) 5'-6 Pv Route 4 DR 1.0490 24.45 9.08 120 0.188714 5'-10 Pf 2.801 593 11'-0 24.45 5.6 19.063 Sprinkler, 9'-0 Pe -0.217 468 11'-6 21.648 2E(2'-0),C(5'-0) 14'-10 Pv - Route 5 DR 1.0490 26.96 10.01 120 0.226106 5'-10 Pf 3.359 588 11'-0 26.96 5.6 23.178 Sprinkler, 9'-0 Pe -0.217 456 11'-6 26.320 2E(2'-0),C(5'-0) 14'-10 Pv OF Route 6 DR 1.0490 28.05 10.41 120 0.243265 9'-10 Pf 4.589 583 11'-0 28.05 5.6 25.085 Sprinkler, 9'-0 Pe -0.217 439 11'-6 29.457 2E(2'-0),C(5'-0) 18'-10 Pv Route 7 ©M.E.P.CAD,Inc. WO AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:28:10PM Page 4 Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length DR 1.0490 28.29 10.50 120 0.247169 0'-6 Pf 1.359 589 11-0 28.29 5.6 25.520 Sprinkler, 5'-0 Pe -0.217 449 11'-6 26.663 T(5'-0) 5'-6 Pv Route 8 DR 1.0490 30.29 11.25 120 0.280545 0'-6 Pf 1.543 584 11'-0 30.29 5.6 29.265 Sprinkler, 5'-0 Pe -0.217 433 11'-6 30.592 T(5'-0) 5'-6 Pv Equivalent Pipe Lengths of Valvesand Fittings(C=120 only) Actual Inside Diameter 4 87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor MultiplyingFactor p 0.713 1.16 1.33 1.51 Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV AlarmValve BL Branch Line Elevation Foot AngV Angle Valve CM Cross MainFlow gpm b Bushing DN Drain BaIV Ball Valve DR Drop Discharge gpm BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Totalpressure at a point in a pipe DeIV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90°Elbow UG Underground Pf Pressure loss due to friction between points EE 45°Elbow Pe Pressure due to elevation difference between indicated Eel 111/4°Elbow points Ee2 221/ Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:28:10PM Page 5 CAST IRON THREADED FITTINGS !6 • Z '11 Ja i - _ •3 _ }.: ''' ':. 't` ir 1Ii1 ip Iv . ,., .*.v. ...„. ..:, - _,. . . .. . .,:.i. -_....-. ,, :.:,„:1: . .-}, _40%.,...._ 441.,.., F - . - . . 'Ilial -W-- .% )00art. F i ] _ _._ • Anvil standard and extra heavy cast iron threaded fittings Cast Iron Threaded Fittings are manufactured in accordance with ASME B16.4.Plugs and Pressure - Temperature Ratings bushings are manufactured in accordance with ASME B16.14. Pressure Temperature Class 125 Class 250 NOTE:Figure 367 Concentric Reducers do not meet the overall length -1°F) (°C) + psi bar psi bar requirement of ASME B16.4. All other dimensions are in compliance. -20°to 150° -28.9 to65.6 175 12.1 400 27.6 200° 93.3 165 11.4 370 25.5 C UL US 250° 121.1 150 10.3 340 23.4 APPROVED 300° 148.9 140 9.7 310 21.4 For Listings/Approval Details and Limitations,visit our website at 350° 176.7 125 8.6 300 20.7 www.anvilintl.com or contact an Anvil Sales Representative. 400° 204.4 - - 250 17.2 Standards and Specifications Dimensions Material Galvanizing* Thread Pressure Rating CAST IRON THREADED FITTINGS Class 125 ASME B16.4 ASTM A-126 (A) ASTM A-153 ASME B1.20.1 ASME B16.4 Class 250 ASME 816.4 ASTM A-126 (A) ASTM A-153 ASME B1.20.1 ASME B16.4 CAST IRON PLUGS AND BUSHINGS 7 ASME B16.14 ASTM A-126 (A) ASTM A-153 ASME B1.20.1 ASME B16.14 "ASTM B 633.Type I,SC 4,may be supplied as alternate zinc coating per applicable ASME B16 product standard. PF-11.16 IPS CARBON STEEL PIPE- FIRE PROTECTION PRODUCTS 10.02 I VICTAULID5 IS AN ISO 9001 CERTIFIED COMPANY Style 005 FireLock® Rigid Coupling VICPlua with Vic-Plus® GasketSystem Gasket System PATENTED PRODUCT DESCRIPTION FireLock®Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves.By permitting the housings to slide on the angled bolt pads,rigidity is obtained. .. : _ The FireLock couplings provide rigidity for valveconnections,fire mains and long straight runs.Support and hanging requirements correspond to NFPA 13 Sprinkler Systems.Angle-pad design permits - assembly by remov ingone nut/bolt and swinging the housing over the gasket.This reduces components to handle during assembly;speeds and eases installation on pipe groovedto Victaulic specifications. Style 005 FireLock couplings with the Vic-PIusTM Gaske t Syste m are de signe dand recommended for use ONLY on fire protection systems. Patented Vic-Plus GasketSystem: Victaulic®now offers a gasket system which requires no field lubrication on wet pipe systems.The VicPIusTM System(patented)is dry,clean,and non-toxic.It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook(1-100)for supplemental lubrication requirements. IIlUI' x , ILII ® 0 ® 11 MOVds § LPC and VdS Approved, Request Victaulic / seenotes on page2. Exaggerated torclarity publication 10.01 for details. DIMENSIONS < Y > I<—Z—sl Dim ensions Pipe Size Inches/in m afrAM �rx�i+ Actual Max. Max. Allow. OA ir l Nominal Outside Work. EndPipe End Sep.f @ Bolt/NutAprx. = Diameter Diameter Press.§* Load* No.-Size Wgt.Ea. � „L _V I_ i Inches/Inches/inm Inches/Inches/inm PSI/kPa LbsJN InJm m Inches/Inches/inm X Y Z Lbs./kg 11/4 1.660 350 755 0.053 2.75 4.50 1.88 1.2 Rated forwetand dry sprinkler 32 _ 42,4 2413 3370 1,2 2 /e X 2/4 70 114 148 0,5 systems at 350 psi(2413 kPa) 11/2 1.900 350 990 0.052 3/8 X 2,/a 3.00 4.75 1.88 1.2 - 40 48,3 2413 4415 1,2 76 121 148 0,5 for 11/4 4"(32 100 mm)sizes 2 2.375 350 1550 0.073.50 5.25 1.88 1.6 and 300 psi(2068 kPa)for 50 60,3 2413 6900 1,7 2-3/8 X 21/2 89 133 148 0,7 41/4 8"(108 200 mm)sizes; 21/2 2.875 350 2270 0.074.00 5.75 1.88 1.9 3 Schedule 10 roll grooved or 65 73,0 2413 10110 1,7 2- /8 X 21/2 102 146 148 0,9 Schedule 40 cut or roll 3.000 350 2475 0.07 4.13 5.75 1.88 1.9 grooved steel pipe.Style 005 76,1 mm 76,1 2413 11010 1,7 2-3/8 X 21/2 105 146 148 0,9 is rigid and does not 3 3.500 350 3365 0.073 4.63 6.13 1.88 2.1 accommodate expansion, 80 88,9 2413 14985 1,7 2- /g X 2/2 118 156 148 1,0 contraction or angular 4 4.500 350 5565 0.163 5.75 7.25 2.13 3.1 deflection. 100 114,3 2413 24770 4,1 2- /a X 2/2 146 184 54 1,4 108,0 mm 4.250 300 4255 0.16 2 s/e X 21/2 5.63 7.25 2.13 3.1 108,0 2068 18940 4,1 143 184 54 1,4 5 5.563 300 7290 0.163 6.88 9.00 2.13 4.5 125 141,3 2068 32445 4,1 2- /2 X 2/4 175 229 54 2,0 5.250 300 6495 0.16 6.63 9.00 2.13 4.5 133,0 mm 133,0 2068 28900 4,1 2 1/2 X 23/a 168 229 54 2,0 5.500 300 7125 0.16 6.88 9.00 2.13 4.8 139,7 mm 139,7 2068 31715 4,1 2 1/2 X 23/4 175 229 54 2,2 6# 6.625 300 10340 0.16 3 8.00 10.00 2.13 5.0 150 168,3 2068 46020 4,1 2 /2 X 2/4 203 254 54 2,3 6.250 300 9200 0.16 7.63 10.00 2.13 5.5 159,0 mm 159,0 2068 40955 4,1 2-5/a X 41/4 194 254 54 2,5 6.500 300 9955 0.16 8.15 10.00 2.13 5.5 165,1 mm 165,1 2068 44295 4,1 2 1/2 X 23/4 207 254 54 2,5 P o 8.62519 2 68 78000 0.19 300 17525 2-5/8 X 41/4 10.2650 17 3343 2.63 15,3 1 *@§t Refer to notes on page 2. #Not available with Vic-Plus gasket system.Lubrication is required. 0 REGISTERED TRADEMARKOF VICTAULIC-0 COPYRIGHT 2004 VICTAULIC-PRINTED IN U.S.A. 1538 REV G Victaulic Company of America•Phone:1-800-PICK-VIC(1-800-742-5842)•Fax:610-250-8817•e-mail:pickvic@victaulic.com Victaulic Comp any of Canada•Phone:905-884-7444•Fax:905-884-9774•e-mail:viccanada@victaulic.com Victaulic Europe•Phone:32-9-381-1500•Fax:32-9-380-4438•e-mail:viceuro@victaulic.be Victaulic America Latina•Phone:610-559-3300•Fax:610-559-3608•e-mail:vical@victaulic.com jctaulic® Victaulic Asia Pacific•Phone:65-6235-3035•Fax:65-6235-0535•e-mail:vicap@victaulic.com 10.02 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request.. Housing Coating:Orange enamel • Optional:Hot dipped galvanized Gasket: • Grade"E"EPDM-Type A Vic-Plus GasketSyste mA (Violet color code). FireLock products havebeen Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure us- ing the Grade"E"Type A Vic-Plus Gasket System,requiring no field lubrication for most installation condi- tions. For dry services,Victaulic continues to recommend the use of Grade"E"Type A FlushSeal®Gasket.Contact Victaulic for details. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to-40°F(-40°C).Based on"typical"pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F(-18°C)and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water.Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has v oidsand/or cracks at the weld seams.Victaulic continues to recommend the use of FlushSeal gaskets for dry sery ices. LISTINGS/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated orking Pressure-PSI Rated Working Pressure-PSI Rated Working Pressure-PSI Pipe Size Pipe Size Pipe Size Sch. Inches UL ULC FM Sch. Inches UL ULC FM Sch. Inches UL ULC FM 5 11/4-3 175 175 175 EL 11/4-2 300 N/A N/A MT 11/4-2 300 N/A N/A 11/4-4 350 350 350 ET 11/4-2 300 N/A N/A STF 11/4-4 N/A N/A 300 10,40 Steady 5-8 300 300 300 EZ 4-6 300# N/A 300 Thd. 11/4-2 N/A N/A 300 BLT 11/4-2 300 300 N/A FF 11/4-4 N/A N/A 300 TF 3-8 N/A N/A 300 DF 11/4-4 300 300 300 GAL-7 11/4-2 300 N/A N/A WLS 11/4-2 300 300 N/A DT 11/4-2 300 300 N/A MLT 11/4-2 300 N/A N/A XL 11/4-3 300 300 300 EF 11/2-4 175(0 N/A 175 MF 11/4-4 300 N/A 300* *FM approved for sery icein 11/2-4"pipe. #UL Listed for sery ice up to 4"pipe only. @UL Listed for sery iceup to 3"only. PIPE SCHEDULE NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe BLT refers to Listed steel sprinkler pipe manufactured by Allied Tube&Conduit DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by Allied Tube&Conduit DT refers to Listed Dyna Thread steel sprinkler pipe manufactured by Allied Tube&Conduit EF refers to Listed/Approved Eddy Flow steel sprinkler pipe manufactured by Bull Moose Tube Co. EL refers to Listed Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. ET refers to Listed Eddythread 40 steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed EZ-Flow steel sprinkler pipe manufactured by Northwest Pipe&Casing Co. FF refers to Listed Fire-Flo steel sprinkler pipe manufactured by Youngstown Tube Co. GAL-7 refers to Listed steel sprinkler pipe manufactured by!DOD Systems,LLC MLT refers to Listed steel sprinkler pipe manufactured by Wheatland Tube Company MF refers to Listed Mega-Flow steel sprinkler pipe manfactured by Wheatland Tube Company MT refers to Listed Mega-Thread steel sprinkler pipe manufactured by Wheatland Tube Company STF refers to Listed Steady Flow steel sprinkler pipe manufactured by AMS Tube Corporation Steady Thread refers to Appproved steel sprinkler pipe manufactured by AMS Tube Corporation TF refers to Tex-Flow steel sprinkler pipe manufactured by Tex-Tube Company WLS refers to Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company XL refers to Listed XL or XL II steel sprinkler pipe manufactured by Allied Tube&Conduit Corp. NOTES *Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t For field installation only.FireLock Style 005 couplings are essentially rigid and do not accommodate expansion/contraction. Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. §Style 005 couplings are VdS and LPC Approved to 12 Bar(175 psi). WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. This product shall be manufactured by Victaulic Company.All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 2 Style 005 FireLock® Rigid Coupling FireLock® Fittings ✓ctaulic° 10.03 Material Specifications: 110111 Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. 1111)E i Fitting Coating: ❑ Orange enamel ❑ Red enamel in Europe, Middle East, Africa, and India O Optional: Hot dipped galvanized Approvals/Listings: c L us LPCB (vds] TP LISTED Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date • victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 ©2014 Victaulic Company.All rights reserved. 1 ictaulic° victaulic.com I FireLock® Fittings I Publication 10.03 Dimensions: k-CtoEl ,__ C 4\ -4 � to 4-� CtoE 4Y. u u c = to o0 010 E --(41 ---.7 I j l_t NO. 001 NO. 003 NO.002 No.006 No.001 No.003 No.002 No.006 90°Elbow 45°Elbow Straight Tee Cap Actual Approx. Approx. Approx. 7 Approx. Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. mm _ mm mm kg mm kg mm kg mm kg 11/4 1.660 _ _ _ _ _ _ 0.82 0.3 32 42.4 21 0.1 11 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 76.1 mm - - 76.1 76 1.5 57 1.1 76.2 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108 mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 - - 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 139.7 mm - - 139.7 124.0 5.6 82.6 3.7 124.0 6.9 159 mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 - - 158.8 140 - 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 mm - - 165.1 139.7 7.9 88.9 5.2 139.7 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 10.03 1539 Rev M Updated 12/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ictaulic° victaulic.com I FireLock® Fittings I Publication 10.03 Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' Nominal Outside No.002 Size Diameter Elbows Straight Tee inches inches No.001 No.003 mm mm 90°Elbow 45°Elbow Branch Run 11/4 1.660 32 42.4 - - - - 11 1.900 - - - - 40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE:When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. • Installation Note R eferenceshould always be made to the I-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks R eferto the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 10.03 1539 RevM Updated 12/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulic° - - - •1 11 .02 Mechanical-T® Bolted Branch Outlets : 1 VdS LPCB VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical-T®Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a "holefinder"locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE:Style 920 and Style 920N 411telilt housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet.Specify choice on order.Units are supplied painted with plated bolts.Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE) pipe.Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe.Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle w hen permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems,utilizes the Style 920 Mechanical-T in conjunction w iththe Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. • Optional:Hot dipped galvanized Gasket:(Specify choice*) • Grade"E"EPDM EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommendedfor cold and hot water service withinthe specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recom m endedfor petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recom mendedfor hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendationsonly.It should be noted that there are services for which these gaskets are not recom m ended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recom mendationsand for a listing of services which are not recommended. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirementsof ASTM A-449 and physical requirementsof ASTM A-183. • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL R IGHTS RESERVED. ICt.sUlilc REV_N 11.02_1 CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each anch Hole V I# VZ Female al Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y >- K Z 1 mm 920N kPa -0.00 mm mm mm mm mm mm kg kg r '1' 2 /'(a)a I 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 I-) 50 x 15 920N 3450 38.1 51 64 41 136 70 1.5 A' m /1 I f�11 3/4(a)0 920N 920N 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 --A0S- 20 3450 38.1 50 64 41 136 70 e1.5 T 1(a)0 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 y25 3450 38.1 47 64 41 136 70 1.4 1'/4(a)to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVEDOUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y K Z N 2 Yz Y(a)§0 920N 500 1.50 2.21 2.74 _ 1.82 5.64 2.75 3.0 x 65 5 3450 38.1 56 70 46 143 70 1.4 tPR11 3/4(a)§0 920N 500 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 V T 20 3450 38.1 55 70 46 143 70 1.4 A Ai k T iff9,,f 1 (a)§o 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 i >--- ---4 -t 4110 w25 920N 3450 38.1 52 70 46 143 70 1.4 yv 1 1/43t2(a)0 920N 5003450 44.5 1.75 2.3058 3.0076 3.2583 1.8246 6.29160 3.0076 3.51.7 3.21.5 FEMALE THREADED OUTLET 11/2 t(a)0 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 I 50.8 58 76 83 46 159 83 1.7 1.6 Y2(a) 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 76.1 x15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4(a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 any location wherea hole can be cut 20 _ 2065 38.1 56 70 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 11/4(a)o 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2(a)0 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 v2(a)n 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450kPa 3A(a)n920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe;also available for use 20 3450 38.1 63 78 - 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1/2"/50 x 15mm 1 Y4(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4"/200 x 100mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 11/2(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)11 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 31/2 2 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 x 50 920N 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N ho usings cannot be **Center o f run to engaged pipe end,female threaded outlet o nly(dimensio nsapproximate). mated to one another t Available with gro ovedo rfemale threaded o utlet.Specify cho iceo n o rder. to achieve crossconnections. # Centerofrun to end offitting. # Female threaded outlets are available to NPT and BSPT specificatio ns. @ See page 7 fo rFire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly o n o rder. (b)Fo r76.1 mm threaded o utlet,specify 21/2"BSPTclearly o n o rder. §Vds approved fo rfire protection services o LPCB approved fo rfire protection services 0 Approved fo ruse in China by Tianjin Approvals Co mpany. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt9UI1C® 11.02_2 REV_N CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Branch Hole V#H V# Female final Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. 4 Y > Z--* mm 920N kPa -0.00 mm mm mm mm mm mm kg kg t TABLE CONTINUED FROM PAGE 2 p� I-7 4x 1/2(a)a 920N 500 1.50 3.03 3.56 1 i 2.69 7.01 2.75 3.7 V 100 15 3450 38.1 77 90 68 178 70 1.8 45. ''''• ' 1311 1 irrR1 - 3/4(a)a 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 ' 20 3450 38.1 76 90 68 178 70 1.8 I- ib y 1(a)a 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 �L 25 3450 38.1 73 90 68 178 70 1.8 GR OOVEDOUTLET 1 Ya(a)to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y > r Z 2(a)to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 t PR 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 V T 2Yz(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 ri te. T I( 11 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 u 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 I I 3450 69.9 73 102 68 186 118 2.9 `� l� 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET - - 1'/4(a)a 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 108.0 x 32 920N 3450 44.5 78 96 67 194 78 2.3 11/2(a)a 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 2.3 any location wherea hole can be cut 2(a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 11/2(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 X 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe;also available for use 21/2(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 • Sizes from 2 x 1/2'750 x 15mm 3450 69.9 95 121 80 246 118 3.6 through 8 x 4"/200 x 100mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 133.0 x50 920N 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 920 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Centerofrun to engaged pipe end,female threaded outlet only(dimensio nsapproximate). Style 920 and Style 920N ho usings cannot be t Available with groovedo rfemale threaded outlet.Specify cho iceo n o rder. mated to oneanother # Centerofrun to end off itting. to achieve cro ssco nnectio ns. # Female threaded outlets are available to NPT and BSPTspecif icatio ns. @ See page 7 fo rFire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly o n order. (b)Fo r76.1 mm threaded o utlet,specify 21/2"BSPTclearly o n order. §Vds approved fo rfire protection services a LPCB approved fo rfire protection services 0 Approved fo ruse in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulice REV_N 11.02_3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each anch Hole V I# V t Female .1 Size 920 Diameter T** Thd. Grv. W Y Z Thd. Gr Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs Y > < Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg r l' 1 ^ TABLE CONTINUED FR OMPAGE3 4 + 139.7 x 1 YZ t 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 V 40 3450 50.8 96 114 84 209 83 3.2 Rs •"'""% til 1 f fR l 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 ' < e50 3450 63.5 95 114 84 209 99 4.1 1 1 o Ya(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 d1 6 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GR 00VEDOUTLET 11/2(a)to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 _130 130 96 232 83 2.4 2.3 2(a)to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 Y Z 2'/2 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 t PR 11 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 T 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 V ' .."-"'• ` 76.1 mm o 920 y 1uiisfil T l 3450 69.9 105 132 94 267 118 3.8 i FSU 3(a)t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 I I 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 + l� 4(a)to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 11/2(a) 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 159.0 x40 920N 3450 50.8 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location w herea hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 In the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 920 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500psi/3450kPa **Centerofrun to engaged pipe end,female threaded outletonly(dimensionsapproximate). on steel pipe;also available for use t Available with gro ovedo rfemale threaded o utlet.Specify cho iceo n o rder. with HDPE pipe t Centerofrun to end offitting. • Sizes from 2 x 1/2"/50 x 15mm # Female threaded outlets are available to NPT and BSPTspecifications. through 8 x 4°/200 x 100mm @ See page 7 fo rFire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly o n order. (b)Fo r76.1 mm threaded o utlet,specify 21/2"BSPT clearly o n order. §Vds approved fo rfire protection services u LPCB approved fo rfire protection services IMPORTANT NOTES: 0 Approved fo ruse in China by Tianjin Approvals Co mpany. Style 920 and Style 920N housings cannot be mated to one another to achieve cro ssco nnectio ns. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt9UI1C® 11.02_4 REV_N CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Hole V t V Female 'Branch al Size 920 Diameter T** Thd.. Grve. W Y Z Thd. Grv. hes or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y > z- m 920N kPa -0.00 mm mm mm mm mm mm kg kg - I TABLE CONTINUED FROM PAGE 4 4 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 a � 165.1 x 920N 25 3450 38.1 99 116 96 237 70 3.6 4o / o''''"• ' lilV� ill /� 1 7a 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 III i, 32 3450 44.5 113 130 96 237 83 3.8 y1 Y(a)tII 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 ii d-L 40 3450 50.8 112 130 130 96 237 83 3.8 GR OOVEDOUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 < Y z 3(a)t e 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 El 1 PR 80 3450 88.9 110 140 130 92 267 135 4.6 4(a)to 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 V Alil �� la, T 1 100 920 3450 114.3 97 146 137 92 267 159 4.8 LEI i FY -- 4, - 8 x 50 2(a)t 200 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 1 3450 69.9 138 157 159 122 316 114 5.3 5.3 01 21/2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 mm a 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location W here a hole can be cut 4(a)to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 s.7 **Centerofrun to engaged pipe end,female threaded outlet only(dimensio nsapproximate). • A pressure responsive gasket provides t Available with groovedo rfemale threaded outlet.Specify cho iceo n o rder. the seal # Centerofrun to end off itting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPTspecifications. Mechanical-T cross assemblies @ See page 7 fo rFire Protection approvals and pressure ratings.' • Pressure rated up to 500 psi/3450kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly ono rder. on steel pipe;also available for use (b)Fo r76.1 mm threaded o utlet,specify 21/2"BSPTclearly o n order. with HDPE pipe §Vds approved fo rfire protection services ❑LPCB approved fo rfire protection services • Sizes from 2 x 1/2'/50 x 15mm 0 Approved fo ruse in China by Tianjin Approvals Company. through 8 x 4"/200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N ho usings cannot be mated to each otherto achieve cro ssco nnectio ns. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulice REV_N 11.02_5 CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss betw een point(1)and (2)for the Style 920,920N and 929 Mechanical-T®fittings can best be expressed in term sof the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. ®2 Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for Cv 1K,Values: 4P = Q2 Where: Q=Flow(GPM) AP = Q2 Where: *AM 2Q=Flow(m3/hr) �� T11 CV AP=Pressure Drop(psi) KVz AP=Pressure Drop(Bar) _________ Q = C„ x A CV=Flow Coefficient Q = K„ x /4P K =Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213,Sec.16) OUTLET SIZE (C=120)t FT Cv/Kv Values NOMINAL ACTUAL DIAMETER O.D. In/mm In/mm GROOVED THREADED GR 00VED THREADED yz 0.840 11 15 21.3 9.4 3/4 1.050 16 20 26.7 13.7 1 1.31521 25 33.7 3 1.8 1 y4 1.660 50 48 32 42.7 5 1/2 6 42.9 41.1 1 Yz 1.900 53 53 40 98.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10 1/2 96 89.1 2 Yz 2.875 119 150 65 73.0 20 12/z 102 128.5 76.1 mm 3.000 16* 161 76.1 138.1 3 3.500 249 237 80 88.9 14 15/z 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient offriction is 120. *Pipe with a wall thickness of0.165in./4.2mm. —1"FireLock''Innovative Groove System(IGS)outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt9UI1C® 11.02_6 REV_N CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIR EPROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication.Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Size Outlet Size Pipe Rated Working Pressures—psi/kPa Actual Nominal Outside Vds Size Diameter Inches/mm Inches/mm Inc es mm c e u e UL ULC ........ (Style 920) (Style 920N) 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 _ _ _ 145 200 219.1 2755 1000 8 8.625 3 4 10 300 _ 250 _ 145 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 _ 300 _ 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinklerpipe. 40 refers to Listed/Approved Schedule 40 steel sprinklerpipe. DF refers to Listed/Approved Dyna-Flowsteel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinklerpipe manufactured by Allied Tube and Co nduit Co rporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4- 8"/100- 200 MM CAR BON STEEL PIPE which is a corn binationof the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450kPa. 11 The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mountedon 4"/10Cn m, 5"/125m m,6"/150mm and 8"/200 mm diameter pipe.The Style 931 comes witha 21/2"/65mm CI grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter(GFCI)in accordance with I safety codes. * 1 iFor more information,refer to publication 24.01. II www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulice REV_N 11.02_7 _ : :e k •IPE- HOLE CUT PRODUCTS 11 .02 iviechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assem bly data, and are available in PDF form at on our websiteat www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assem bly instructions.Victaulic reserves the right to change product specifications,designs and standard equipmentw ithout notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV N UPDATED 12/2017 iCtsuIi�i VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIG HTS RESERVED. 11.02_L • FireLockv9 Outlet-I = STYLE 922 1 A WARNING A WARNING Ali 0 N... miI .. • Read and understand all instructions before attempting to • Depressurize and drain the piping system before attempting to install any Victaulic piping products. install, remove,or adjust any Victaulic piping products. • Wear safety glasses,hardhat, and foot protection. Failure to follow this instruction could result in serious personal Failure to follow these instructions could result in serious injury and/or property damage. personal injury and/or property damage. The Style 922 FireLock Outlet-T is designed for direct connection of sprinkler heads, drop nipples,sprigs,drains,gauges,and other outlet products. The Style 922 FireLock Outlet-T is UL Listed and FM Approved up to 300 psi/2068kPa and VdS Approved up to 16Bar/232psi at ambient temperatures that are typical for fire protection systems. PRODUCT DATA Nominal Size Hole Approx.Wgt. inches/mm Diameter Dimensions-inches/millimeters Each Y *-Z +0.06/+1,5 Run x Branch FPTt -0.00/-0,0 T* V W Y Z lbs/kg V ��� jr `v/ 1 Ya Yz 13 6 1.30 1.83 1.10 3.87 Z.55 1.0 ���� w 32 x 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 ' ' = 3A 13/6 1.28 1.83 1.10 3.87 2.56 1.1 Tit w 1 ' 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 �/ 16dii 1 13/6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1 Yz Yz 1 3/16 1.42 1.95 1.22 4.08 2.56 1.2 40 x 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3A 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 Yz 13/16 1.66 2.19 1.46 4.60 2.56 1.3 50 x 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3A 13/6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13A6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2Y 1/2 13A6 1.91 2.44 1.71 5.40 2.56 1.6 65 x 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3A 13A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 13A6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm x 1/2 13A6 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3A 13/6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(Optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pendent s prinklerheads,etc.,s hould be verified as suitable for us e with this Victaulic product.Failure to verify suitabilityin advance may result in as s emblyproblems or leakage. *Center of run to engaged pipe end for NPT threads(dimens ions are approximate). www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2004 VICTAULIC COMPANY.ALL RI GHTS RESERVED.PRINTED I N THE USA. jctaulic' REV C 1-922_1 INSTALLATION INSTRUCTIONS 1-922 FireLock® Outlet T STYLE 922 PIPE PREPARATION Lower • NOTICE �� Housing • Victaulic hole cutting tools are recommended for proper hole ,. preparation. - • 'SI' 1. C ut a hole on the centerline of the pipe.Refer to table on page 1 for hole requirements. f ‘r.. _'h inch/13 mm Outlet ` A _ Housing 2. I nserta bolt into the outlet housing and lower housing,and thread I I a nut loosely onto the bolt(nut should be flush with end of bolt)to WI allow for the"swing-over"feature,as shown above. Exaggerated forclarity • 2. Ensure that a1-inch/13-mm area around the hole is clean, I smooth,and free from indentations and/or projections that could affect gasket sealing(refer to the sketch above). Remove any burrs - and sharp or rough edges from the hole that might affect assem- . -. , bly,proper seating of the locating collar,flow from the outlet,or gasket seating. I ,�- *; INSTALLATION ', ,tf;, • • 3. Install the outlet housing onto the pipe by centering the locating q,T. ',me,. • collar in the hole.To check for proper engagement,slide the outlet housing back and forth while pushing down.A properly positioned outlet housing can be moved only a small amount in any direction. 3a. Rotate the lower housing around the pipe,while holding the outlet housing in place to make sure the locating collar remains seated properly in the hole. wan._ AMA .:..., • 1. Install the gasket into the gasket pocket,as shown above.Press the gasket along the full circumference to ensure that it fully seats in the gasket pocket. DO NOT LUBRICATE THE GASKET. •4= • I re r . _. .iiiiimi 4. Insert the other track bolt into the outlet housing and lower housing. I nstall the nut finger-tight. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2004 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED I N THE USA. iCtauIIC® I-922_2 REV C INSTALLATION INSTRUCTIONS 1-922 FireLock° Outlet-T STYLE 922 r •• • . J • 5. Tighten the nuts evenly to an approximate torque value of 20ft-lbs/27.1-Nom to ensure proper gasket compression.NOTE: To avoid over-tightening the nuts, use a wrench with a maximum length of 8 inches/200mm.DO NOT over-tighten the nuts. I - s t The outlet housing, near the gasket,should not make metal-to-metal contact with the pipe.I n addition, a small gap is expected between the outlet housing and the lower housing,as shown above. WARNING • DO NOT over-tighten the nuts.Over-tightening the nuts can over-compress the gasket and distort the outlet housing and lower housing.Over-tightening does not enhance product per- formance. Failure to follow this instruction could cause product failure, resulting in serious personal injury and/or property damage. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2004 VICTAULIC COMPANY.ALL RI GHTS RESERVED.PRINTED I N THE USA. •CtauIic REV_C 1-922_3 I, . : ., , ., 1-922 FireLock® Outlet T STYLE 922 IIIIIIIIIIIIIIIIIIIIIIIIII WCAS-65GJLA • For complete contact information,visit www.victaulic.com 1-922 3393 REV C 2100922000 UPDATED 3/2004 ictaulic VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2004 VICTAULIC COMPANY.ALL RI GHTS RESERVED.PRINTED I N THE USA. 1-922 0) 1.0LCO, ,nr,n„n,.tolco•com aHand afNIBCO" Revision 12/18/2008 Fig. 200 - "Trimline" Adjustable Band Hanger C0 LIS LISTED Fig. 200R (Import)- "Trimline" Adjustable Band Hanger 4> w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 >• specifications �� �� `� Function— For fire sprinkler and other general piping ``�`" 4/ purposes. Knurled swivel nut design permits hanger � 3 " -\„ adjustment after installation. , (a/ ,, ,, Features — Ti • (1/2" thru 2") Flared edges ease installation for B 1 B all pipe types and protect CPVC plastic pipe ,,, r„ ,-, „ from abrasion. Captured design keeps adjusting A , nut from separating with hanger. Hanger is eas- *'\` ily installed around pipe. A • 1 _- 2/2" thru 8 Spring tension on nut holds it � ___ ( ) p g securely in hanger before installation. Adjusting nut is easily removed. Fig.200 1" -2" Fig.200 21/2-8" Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL)and Canada(cUL) 411!!e . for steel and CPVC plastic pipe and Factory Mutual 'V u\ Engineering Approved (3/4"thru 8"). Conforms to «;;::.::. . Federal Specifications WW-H-171E, Type 10 and ® `� Manufacturers Standardization Society SP-69, Type 7-, 10. B Maximum Temperature — 650°F I B Finish — Mil. Galvanized.Stainless Steel materials will =" ��,�I be supplied with (2) hex nuts inplace of a knurl nub. Pp '-„ II, Order By — Figure number and pipe size A Note— Figure 200R (import) with retainer ring and A ..- Q::-----;-:::'' non-captured knurl nut. Fig.2O0R 21/2"-8" Fig.2O0R 1/2" -2" Dimensions•Weights Pipe Rod Size Max.Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/s 21/2 400 11 1 3/8 8mm or 10mm 33/s 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/s 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/2 600 27 3 3/8 10mm 57/s 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/s 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/2 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX:951.737.0330 CUSTOMER SERVICE•800.786.5266 91 www.tolco.com RODS & EYE RODS 0.4wR4 Fig. 146 (Formerly Afcon Fig. 650) Continuous Threaded Rod Size Range:1/4"through 11/2"Stocked in six,ten,and twelve foot lengths.Other even foot lengths can be furnished to order. Material:Carbon steel or Stainless Steel Gr 304 Threads:National Coarse(USS), rod threaded complete length. "il l'"'i�'` "tl"'°it'F it �I+F+Uu + ti Finish:['Plain or❑Zinc Plated (Hot-Dip Galvanized optional) Maximum Temperature:Zinc Plated 450°F,Stainless Steel 650°F Approvals:Complies with MSS SP-58. Ordering:Specify rod diameter and length,figure number, name and finish. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. FIG. 146: DIMENSIONS(IN)•LOADS(LBS)•WEIGHTS(LBS) Rod Size Threads Max Load Weight A per Inch 650° F per Ft. Length �i 1/4 20 240 0.12 3/a 16 730 0.30 IMMISSOMOSI������������������SISIONSMISSISMOSNI I '/ 13 1,350 0.53 5/8 11 2,160 0.84 A 3/a 10 3,230 1.20 7/8 9 4,480 1.70 1 8 5,900 2.30 _ 11/4 7 9,500 3.60 11/2 6 13,800 5.10 PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: SubmittalDate: Notes 1: Notes 2: PH-1.18 BEAM CLAMPS 4NviL Fig. 93 (Formerly Afcon Fig. 105) Universal C-type Clamp (Wide Throat) Size Range:3/8"and 1/2" Material:Ductile iron clamp,hardened steel cup point set screw and locknut. --- Finish:❑Plain or['Zinc Plated(H ot-Dip Galvanized optional) Service:Recommended for use under roof installations with bar joist type constructions, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of ri) joist or flange does not exceed 1 1/4" . Approvals:Complies with Federal Specification A-A-1192A(Type 19&23), WW-H-171-E(Type 23) ANSI/MSS SP-69 and MSS SP-58(Type 19 &23).UL,ULC Listed and FM Approved. `--...- How to size:Size of clamp is determined by size of rod to be used. ... . - Installation:Follow recommended set screw torque values per MSS-SP-69. Features: • They may be attached to horizontal flanges of structural members in either the top beam or bottom beam positions. 6 • Secured in place by a cup-pointed Set Screw tightened against the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. • Wider throat for attaching to flange with up to 11/4"thickness. CO US 41> Ordering:Specify rod size,figure number,name of clamp and finish. LISTED APPROVED 1 [0-H-0- C ' �F� killi E. AT LEAST ONE SO G �_ FULL THREAD 1n OF ROD MUST 1 r BE EXPOSEDVI I 11/3" I- D " • ii BODY I I CASTING NO MIN EN OM A i JAM NUT _ :: SET-SCREW FIG. 93:DIMENSIONS (IN) • LOAD(LBS)•TORQUE(IN-LBS) •WEIGHT (LBS) Rod Set Torque Max Loads■ 0 Size Screw Value Weight C D E F G H A Size Top Bottom 3/8 3/8 60 500 250 0.41 1%6 25A2 9/6 13A6 3/8 5/8 : • 1/2 1/2 125 950 760 0.75 13/8 211/32 1/2 11/6 7/6 13/6 •Maximum temperature of 450°F PROJECT INFORMATION APPROVAL STAMP Project: ['Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.18 SAMMYS f orWood SELECTION CHART i i I SAMMYS Vertical Mount • Part#8113910 •Part#8114910 ROD PART ULTIMATE ® TEST ® TEST BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT (LBS) us LOAD LOAD QTY QTY NUT DRIVER LISTED (LBS) APPROVED (LBS) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 Part# 8113910 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 Part 81149 P ! SAMMYS Horizontal Mount TEST ROD PART MODEL DESCRIPTION ULTIMATE UL LOAD BOX CASE NUT DRIVER ts.1.66,04..„.40, SIZE NUMBER PULLOUT (LBS) CLISTEDUS (LBS) 3/8" 8021957 SWG20 1/4x2" 1725 (Fir) 1050 25 125 Part# 8114910 3/8" 8022925 SWG25-380 3/8x 2-1/2" 2249(Fir) 1500 25 125 FloorJoist SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-offfeature which provides a fast and safe in stallation each time.When the face of the driver comes in to con tact with the material you are installing into,con tin uedrilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. S6 SAMMYS® T[ Construction Products" Call our orvisitwww.itwconstruRion.ca forgeneralinformation. VisitITWBuildex'sSAMMYSwebsitewww.sammysuperscrew.comforthemostcurrentproductand technical information. SAMMYS f o rWood- m T-_E-STD oSeismic Restraint 45°as reer : Z I. T '? RfOt4A H UIREMENTS installation] AA sca\`O 1'1E88 CSE DRIES C.D.E. & F SIDEWINDER FOR 3/8" & 1/2" RODS SPECIFICATIONS SWG 20 AND SWG 25-380 FOR 3/8rr ROD Restrained PipeSize: Up to Schedule 40 pipe 2"or less Max Length of Structural attachmentfittingforinstallationof RestraintMaterial: See Maximum Horizon talLoad Tables below. branch/end of lin erestrain tusing 3/8"threaded rod.Designed foruse in wood structuralmember Maximum Angle: 45°fromhorizontal witha min imum thicknessof 2"(nominal1-1/2"). Material: CarbonSteel 4* Can be used in compositewood joists;con suit ScrewDescription: (SWG 20):1/4"-10 x 2"wood screw man ufacturerforrecommendedinstallationpoint. (SWG 25-380):3/8" 10x2-1/2"wood screw Thesefastening systemsprovidea securean d Finish(both): Electro zinQcap&fastener) econ omicalattachmentto thestructure. NI % ��1 Testing: BX Report#R-1362 ��'�l' TheSWG 20 an dSWG 25-380 models providea p O'Jl� one pieceupperstructuralattachmentin awide Listing: UL 203 as a pipe han geral ran geof wood thickn essesPre-drilling may be UL 203A pen ding C LISTED s required formodel SWG 25-280. Installation: Must be installed with#14 SW Red Nut Driver (PartNo.8114910) SELECTION CHART SAMMYS f orWood-Seismic Restraint ROD PART MODEL MIN APPLICATION BOX CASE SIZE NUMBER THICKNESS QTY QTY 3/8" 8021957 SWG 20 1-1/2" Wood,Dim. Lumber,TGI/TJI Joist 25 125 3/8" 8022925 SWG 25-380 1-1/2" Wood,Dim. Lumber,TGI/TJI Joist 25 125 PERFORMANCE TABLES Maximum Rod Lengt hf orl/r=100,200,300,an d400 LEAST RADIUS OF MAXIMUM ROD LENGTH FOR I/r(ft) RESTRAINT SHAPE AND SIZE NOMINAL DIAMETER AREA(in.2) GYRATION, r(in.) I/r=100 I/r=200 I/r=300 I/r=400* Rods(all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 Rods(threaded at ends on ly) 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Referen ce:NFPA 13, (2007) *Referen ce:NFPA 13, (2010) %%TN7Construction Products'" Call our toll freenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneral information. SAMMYS.. S 7 VisitlTW Buildex'sSAMMVSweb sitewww.sammysuperscrew.com forthe most currentproductand technical information. SAMMYS® DESCRIPTION/SUGGESTED SPECIFICATIONS Selfdrilling &sel ftapping in tosteelup to Anchors 1/2"thick— The Steel Sammy is made usin gTeks°self-drilling fasten ersperfectforHan gin gSprin klers,Pipes,Electrical forSteel Fixtureor HVAC Equipmen tto steel purlin,structuralbeams,an d open web joist. The Steel Sammy is available in vertical mount,horizontal mount,andSwivel mounttoaccommodateall fastening situations. Installs into Steel ADVANTAGES Structures Easily Made with Teks°self-drillin gfasten ers— Reduces in stallationcost. n opre drillingrequired. Quickto install using the Sammy Nut Driver and Quickly! - In stallin tosteel ran gefrom 22 gauge— with a n oload speed 2000-2500 rpm, 1/2"thickn ess minimum 6 amps drill/driver. Available • Savestimefromtraditional methods. in Vertical Sammy's Vertical Mo unproductFeatures and Horizontal I &AAI A N® ttituNG , RE REQUIRED .I 'sr n ~I 11, i • 4. , VERTICAL MOUNT MADE MR Sammy's Sidewinder® Product = N® fLLING Features pNE RNEQUIRE® • MADE WITH S ►EWINDERS® F STEEL ONTAL s r T .ukkUMiffiki 5 8 SAMMYS® r8T[ Construction Products` Call ourtollfreenumber800-387-9692 orvisitwww.itwconstruRion.ca forgeneralinformation. Visit ITW B uildex'sSAMM VSweb site www.sammysuperscrew.com f orthe most currentproductand technical information. SAMMYS f orSteel APPLICATIONS APPROVALS -r Sprin klerSystems See SelectionChartforitemswith approvals. ' �- Pipes/Plumbing ,a ElectricalLighting an dFixtures - HVAC Equipmentan dFixtures INSTALLATION INSTRUCTIONS %f: VERTICAL MOUNT . A ti, `` . - Fig.1 Fir 2. Fig. Fir.4 .;� 1. In sertthe appropriaten utdriver intoa 3/8"or1/2"portabledrill. 2. InserttheSAMMYS intothe#14(black)n utdriver(p/n8113910). Drill should be in a vertical position. Pushthe faceofthe n utdrivertighttothe member.Whenthe nut 3 .,` driverspinsfreelyon the SAMMYS,stop drill andremove. The SAMMYS is n owreadyto receivel/4",3/8",1/2"or metricall , thread rod,bolt stock.(The 1/2"requiresthe#14SW red n utdriver) Important Vertical Installation Notes I lit Info b Warrantyrequirestheuseofappropriatenutdriversforinstallation. • Model#14 Nut Driver Item No:100 Color:Black I Use With Sammysforl/4"and3/8"Rod PN 8113910 M Eye protectionshould be wornat all timeswhen installing this product. ( I INSTALLATION INSTRUCTIONS HORIZONTAL MOUNT Mir 1 11 1 IR gigr 7 omit i N -iiI Fig.1 Fig 2. Fig.3 ig.4 1. In sertthe appropriaten utdriverintoa 3/8"or 1/2"portabledrill. 2. In sertthe SAMMYS in tothe#14W(red)n utdriver(p/n8114910). With drill un itin a horizontal positionan dat a rightan gleto the structural member,begin installation. 3. When the n utdriverspin sfreeon the SAMMYS,stop drill an dremove. 4.The un itis n owreadyto receivel/4",3/8",or metricall thread rod, bolt stock. ImportantHorizontallnstallation Notes Warrantyrequirestheuse of appropriaten utdriversforinstallation Sidewin dersmust be installed using Model#145W(Red)n utdriveron ly.ltem No:101 PN:8114910 Eye protectionshould be wornat all timeswhen installing this product. ITL WConstruction Products'" Call our toll freenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneral information. SAMMYS' 9 C VisitlTW Buildex'sSAMMVSweb sitewww.sammysuperscrew.com forthe most currentproductand technical information. .7 7 SAMMYSf orSteel SELECTION CHART i i 1 SAMMYSVertical Mount • Part#8113910 ■ Part#8114910 ilROD PART ULTIMATE ® TEST ® TEST MIN MAX BOX CASE NUT SIZE NUMBER MODEL DESCRIPTION PULLOUT us LOAD LOAD THICKNESS THICKNESS QTY QTY DRIVER (LBS) LISTED (LBS) APPROVED (LBS) 3/8" 8038957 DSTR1* 1/4-20x 1"TEKS3 1510 (20ga.) 1500 1475 .036"-20ga 3/16" 25 125 �� 3/8" 8039957 DSTR516" 5/16-18x1-1/4"TEKS3 2200(20ga.) 1500 1475 .036"20ga 1/8" 25 125 3/8" 8040957 DST10 1/4-14x 1"TEKS3 446(20ga.) .036"-20ga 3/16" 25 125 Part# 970(16ga.) 8113910 3/8" 8041957 DST15 1/4-14x1-1/2"TEKS3 446(20ga.) .036"-20ga 3/16" 25 125 970(16ga.) 3/8" 8046957 TEK50 12-24x 1-1/2"TEKS5 3125 (3/16") 1500 1475 .187"-3/16" 1/2" 25 125 SAMMYS Horizontal Mount 3/8" 8055957 SWDR1* 1/4-20x 1"TEKS3 1900(20ga.) 1500 1475 .036"-20ga 3/16" 25 125 Part# 3/8" 8056957 SWDR516* 5/16-18x1-1/4"TEKS3 2480(20ga.) 1500 1475 .036"-20ga 1/8" 25 125 8114910 *In cludesretain in gi ut SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-offfeature which provides a fast and safe installation each time.When the face of the driver comes into con tact with the material you are installing into,con tin uedrilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. PERFORMANCE TABLES SheetSteelGauges GAUGE NO. 26 24 22 20 18 16 14 1 12 1 3/16" 1/4" Nominal Decimal Equivalent .018 .024 .030 .036 .048 .060 .075 .105 .188 .250 Ultimate Pull outValues (Ay,.Lbs.Ultimate)-SAMMYS FASTENER STEELGAUGE(Lbs.) MODEL DIA. PT 20 18 16 14 12 3/16" 1/4" DST 1/4" #3 446 613 970 1145 1544 3190 DST516 5/16" #3 457 568 1209 1712 2422 TEK50 #12 #5 487 699 913 1527 3270 3593 DSTR1-1/2" #12 #5 3270 3593 DSTR1" 1/4" #3 1510 DSTR516 5/16" #3 2200 Al uminumCurtain W al!Extrusion Ultimate PulloutValues (AVERAGELBS.ULTIMATE) FASTENER THICKNESS MODEL DIA. PT. .114 .092 .365 .132 DST10 1/4 #3 1265 2750 SWD 10 1/4 #3 1120 1420 Ultimate Pullout Values (Av..Lbs.Ultimate)-SIDEWINDERS FASTENER STEELGAUGE(LBS.) MODEL DIA. PT 20 18 16 14 12 3/16" 1/4" SWD 1/4" #3 1477 SWDR1-1/2" #12 #5 2375 SWDR1" 1/4" #3 1900 1900 SWDR516 5/16" #3 2480 2480 ITNY Products" 510 SAMMYSCall ourtollfreenumber800-387-9692 or visitwww.itwconstruction.ca f orgeneral information. Visit ITW Buildex'sSAMMYSweb sitewww.sammysupersaew.com forthe most currentproductand technical information. SAMMYS f orSteel- Seismic Restraint DESCRIPTION (SIDEWINDER) TESlEO SWDR1-1/2 AND SWDR516 FOR 3/8"ROD ' �aA .•C"‘‘.1 G�.r ER Structuralattachmen tf orin stallationof branch/end of lin erestrain tusing 3/8"threaded rod.Used RE 1JIREMEMTg primarily in purlin,barjoist,orothersteel structural members.Thesefastening systemsprovidea secure %• i ) andeconomicalattachmenttothe structure. SCA‘.4c TE ICOgThe SWDR1-1/, model providesupperstructuralattachmen tin a ran geof steelthickn essesfrom3/16" CRTM ESORIES throughl/2". A retain in gi utis in cludedwitheachfastener. C.D.E. & f The SWDR 516 model providesupperstructuralattachmen tin a ran geof steelthickn essesfrom20 ga. throughl/8". A retain in gl utis included witheachfastener. 1/,,,,,_ Alk„ SPECIFICATIONS Restrained PipeSize: Up to Schedule 40 pipe t"or less 0.4 Max Length of RestraintMaterial: See Maximum Horizon talLoad Tables below. , ;, I i Maximum Angle: 45°fromhorizontal v Material: CarbonSteel Cho. ScrewDescription: (SWDR 1-1/2):12-24 X 1-1/2"Teks®5 j �� ) (SWDR516):5/16" 18X 1-1/4"Teks®3 Swivels i (� 0 Finish(both): Electro-Zinc(cap)SilverClimaseal®(screw) 45°—fogiamTesting: BX Report#R-1362 proper Listing: UL 203 as a pipe han ger installation! UL 203A pen ding ®us SELECTION CHART SAMMYS Sidewinders f orStee! Seismic Restraint ROD PART MODEL MIN MAX APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER THICKNESS THICKNESS QTY QTY 3/8" 8056957 SWDR516 16 ga. 1/8" Steel PurlinorBarloist 25 125 TheSWDR 1-1/2 andSWDR516 must be installed with#14 5W Red Nut Driver(PartNo. 8114910). No pre-drilling required. PERFORMANCE TABLES Maximum Horizontal Loadsf or Restraint with)/r=100, 200,300,and400 RESTRAINT SHAPE AND SIZE NOMINAL AREA(in.') LEAST RADIUS OF MAXIUMU ROD LENGTH FOR Ur(ft) DIAMETER GYRATION, r(in.) I/r=100 I/r=200 I/r=300 I/r=400* Rods(all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 Rods(threaded at ends only) 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Ref erenCe:NFPA 13, (2007) *Ref erenCe:NFPA 13, (2010) yTN7Construction Products" Call our toll freenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneral information. SAMMYS' S 11 VisitlTW Buildex'sSAMMVSweb sitewww.sammysuperscrew.com forthe most currentproductand technical information. SAMMYS® DESCRIPTION/SUGGESTED SPECIFICATIONS SammyX-Press Revolutionizes T h ePipe Sam my Handing Trades— The Sammy X-Press®System is designed to providedirectattachmentofthreaded rod inmetal deck X Press° (22-16 gauge)andthingauge purlin(18-16gauge),while providing reduced installationcostsinterms of time andmaterials.TheX-PressAnchorseliminatetheneed forcostly"armovers"in pipe hanging in stallation s.Currentmethodsoffered forthin gauge purlin requireuse of a time-consuming retain in g n uton the threaded portionofthe fasten erto preventpullout Installs into f an dare n otdesigned foruse in metal deck.ln man yin stan ces, accessto the backsideof the installed fasten eris prohibited MetalDeck, by pan ellin eror roofing in sulation Sammy X-Press®an chors deliverthe performan can stallersrequirewithoutthe use of a Purlin, or retaining nut! Tubular Steel Sammy X-Press The patent-pending X-PressAn chorscon sistof a threaded fasten elan dexpan dablesleeve.TheX-PressSystem features an easy-to-in stalbn chorwith expanding anchoring stripsthat collapseto preventpulloutafterinstallation. TheSammyX-Press®It In stallationToolassuresa perfectinstallationeverytimeofferin gheaddedconvenience of one-tool efficien cy—just drill an ddrive in secon ds!SECONDS! i 11 ADVANTAGES In stallsin secon ds,saving time& • Less jobsitematerial n eeded. - installationcosts. • No retaining n utrequired. Use in application swhereaccessto the back of Providesdesign flexibility. the installed fasten ens prohibited.ie.metal roof deck,tubularsteel,orvapor barrierfabric. r...‘ . • _ Sammy's X-Press, Swivel an dSidewinder The Sammy X-Pressexpan dsto provide directverticalattachmen tin: 1xPff - Metal Deck(22-16 gauge) 6935,821 Z Purlin(18 16 gauge) The Sammy X-PressSwivelallows you to han gplumb in extremeroofpitches: (swxP) II -89°in Z-Purlin Paten Pen ding -45°in metal deckfor 12/12 pitch Foil The Sammy X-P ressSidewinderex pan ds (SXP) 'y1 i EXaftE t to provide horizon talattachmen tin: Paten leen ding V PRINNA -16 ga-3/16"steel-purlin,tubular steel. - ROOF p'1CRES !T[ Construction Products` S 12 SAMMYS Call our tollfreenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneral information. Visit ITW B uildex'sSAMM VSweb site www.sammysuperscrew.com f orthe most currentproductand technical information. SammyX-Press APPLICATIONS APPROVALS Sprin klerSystems The X-PressSystemhas earned the 9R21 and25ESULListing. r_ 7 Pipes/Plumbing Electrical Lighting and Fixtures HVAC Equipmen tan d Fixtures W 1111111111--,--111111 _/ INSTALLATION TOOL SAMMYX-PRESSIT' INSTALLATION TOOL INSTALLATION INSTRUCTIONS UXPIT • ,* r Paten Pen din g 4 PART MODEL DESCRIPTION EACH ' �I NUMBER QTY 8194910 UXPIT* Universal X-Press It Tool 1 1.Pre-Drill. 2. AttachSleeve. 3. InsertAnchar. Install. 8152910 XPDB 25/64"Drill Bit 1 TowatchavideodemonstrationoftheSammyX-Press,visithttp://www.sammysuperscrew.com/sammyxpress.htm *Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. ITL WConstruction Products'" Call our tollfreenumber 800-387-9692 or visitwww.itwconstruction.ca forgeneral information. SAIVIIVIYS.. C 13 VisitlTW Buildex'sSAMMVSweb sitewww.sammysuperscrew.com forthe most currentproductand technical information. .7 SammyX-Press SELECTION CHART SAMMYS X-Press Vertical Mount ROD PART ULTIMATE ® TEST UL MIN ®LOAD TEST FM MIN MAX BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT c us LOAD THICK THICK THICK QTY QTY APPLICATION (LBS) LISTED (LBS) APPROVED (LBS) 1146 185(Luminaire) .027" 1/4" 8181922 XP200 X-Press200 .125" 25 125 Metal Deck (22ga) 250(Luminaire) .056" (XP) 850(2t1z"Pipe) .027" 940(2"Pipe) Paten No. 11 1146 185(Luminaire) .027" .029" 6,935,821 3/8" 8150922 XP 20 X-Press20 1475(4"Pipe) .125" 25 125 Metal Deck (22ga) 250(Luminaire) .056" .104" 283(Con duit&Cable) .029" 1500(4"Pipe) .060" 3/8" 8153922 XP35 X-Press35 1783 85(Luminaire) .029" 940 (2"Pipe) .029" .125" 25 125 Purlin (16 ga) 250(Lumin aire) .056" 1475(4"Pipe) .104" 416(Con duit&Cable) .059" Metal Deck 3/8" 8150922 XP20 XPress20 1146 g50(2YzPipe) Pre-PourStructuralConcrete@B000 psi (Pre-Pour) — (22 ga) Post-PourRangel ILWC<_35 PCF(Ibs/ft3) 25 125 Metal Deck (Post-Pour) Pre-PourStructuralConcrete@ 3000 psi kyle Post-PourRangell LWCs35 PCF(Ibs/ft' a s 'Vi% }4vft:aat • SAMMYS X-Press Swivel Head° ULTIMATE TESTTEST ROD PART ® UL MIN ® FM MIN MAX BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT Us LOAD THICK LOAD THICK THICK QTY QTY APPLICATION (LBS) LISTED (LBS) APPROVED (LBS) 750(2"Pipe) sXP> 1061 170 vertical(Lumin aire) FOH Swivel (22 ga Vertical) 80@45°(Luminaire) Paten Pen ding tx l:• 3/8" 8294922 SXP20 283 vertical .029" 635(2"Pipe) .029" .125" 25 125 Metal Deck off X Press20 829 (Con duit&Cable) L 1�1IA (45°OffVertical) 233@45° PO PITCHES (Con duit&Cable) 1250(3-1/2"Pipe) 1675 250 vertical(Lumin aire) Swivel (16gaVertical) 80@90°(Luminaire) 3/8" 8295922 SXP35 X Press35 1558 500 vertical .059" 635(2"Pipe) .029" .125" 25 125 Purlin (89°Off Vertical) (Con dud Cable) 333 @ 89° (Con duit&Cable) SAMMYS X-Press Horizontal Mount ROD PART ULTIMATE ® TEST ® TEST MIN MAX BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT c us LOAD LOAD THICK THICK QTY QTY APPLICATION (LBS) LISTED (LBS) APPROVED (LBS) Sidewinder 1250 (31/2"Pipe) Paten Pen 3/8" 3/8" 8293957 SWXP35 X-Press35 1798(16 ga) 80(Luminaire) .060" .125" 25 125 Purlin 416(Con duit&Cable) (SWXP) ' ITT Construction Products` S 14 SAMMYS® Call our tollfreenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneral information. Visit ITW B uildex'sSAMM VSweb site www.sammysuperscrew.com Seethe most currentproductand technical information. SAMMYS X-Press f orSeismic orSeismic i, DESCRIPTION Lx.f-ttgaiD wooer FEATURES BENEFITS installment IAF Structuralattachmentand • Reduced installationcost. restraintcompon en tcombin ed; • Design flexibility. 1 readyforselected rod. • Lesson site material(GO GREEN). Accesstothebackoffastener • Less materialcoordination. Li 14 z F 4 n otrequired. • Aestheticall leasin t_ a - Does n otrequire use of a yp g' *141_ carzPerlin ,,7 metal Deck *, retainingnut. TESTED TO �1 ---- Quickandeasyinstallation. � RE r UIREE , i ••� a , MENTg :$.�:1 FOR 3/8" AND 1/2" RODS SPECIFICATIONS sca�� 'tEstED TO SEISMIC DESISII SXP 20 AND SXP 35 FOR 3/8"ROD FOR 3/8"ROD AND 1/2" ROD cAtesoa►Es C.D.E. s F Structural attachmen tforinstallationof branch/end of lin erestraintusin g Restrained PipeSize: Up toSchedule 40pipe 2"or less 3/8"all thread(.299"0D)or end thread rod(374"OD)' Max Lengthof SXP20 for3/8"Rod:Designed foruse in metal deck ranging from22 ga. RestraintMaterial: See Maximum Horizon talLoad Tables below. through18 ga.in low slope or pitched roof design s(12/12). Maximum Angle: 45°fromhorizon tal SXP 35 for3/8"Rod:Designed foruse in steel purlin ranging froml6ga. Material: CarbonSteel through 1/8"in low slope or pitched roof design s(12/12). The Swivelsmay be used to attachshort len gthof rod to elimin atelateral ScrewDescription: 1/4"-20 x 1-1/8"with expan dablesleeve sway bracing per NEPA 13,9.3.5.3.8,(2007). Finish: Electro-Zinc SXP 2.0 AND SXP 3.5 FOR 1/2"ROD Testing: Tested to GR-63-COREStandard for performan cdn attachmentforinstallationofbranch/end of lin erestraintusin g structuralsteel in seismic restrain tapplicationsas outlined foruse in NFPA 13 (2007), Structural all thread(.405"OD)orendthread rod(.500"OD). 9.3 at an in depen den testlab.The calculated forceused f orthe testing was equal to 1/2thatfound in a Zon e4 an dan 8.4 Richterscaleseismiceven t. SXP2.0for1/2"Rod:Designed foruse in metal deck ranging from22 ga. Listing for3/8"Rod: UL 203 listed as pipe han gerF ile EX 5098 FM through 18 ga.in low slope or pitched roof design s(12/12). -SXP 20(22 ga.)0-45°fromhorizontal-2"Schedule40 pipe °° " SXP3.5 forl/2"Rod:Designed foruse in steel purlin ranging from 16 ga. -SXP 35(16 ga.)0-90°fromhorizontal-3-1/2"Schedule40 pipe ®us through 1/8"in low slope or pitched roof design s(12/12). UL 203A File EX 15565 CIOUS "STE° The Swivelsmay be used to attachshortlen gthof rod to elimin atelateral LISTED sway bracing per NEPA 13,9.3.5.3.8,(2007). Listing fort/2"Rod: UL 203A File EX 15565 u�U5 LISTED SELECTION CHART SAMMYS X-Press Swivels-Seismic Restraint ROD PART MODEL MIN MAX APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER THICKNESS THICKNESS QTY QTY 3/8" 8294922 SXP 20 22 ga 18 ga. Metal Deck 25 125 The SWXP 35 must be in stalled with UXPITTooI(PartNo. 3/8" 8295922 SXP 35 16 ga 1/8" Perlin 25 125 8194910);pre-drilling required. PERFORMANCE TABLES Maximum RodLengthf orl/r=100,200,300,and400 LEAST RADIUS OF MAXIMUM ROD LENGTH FOR I/r(ft) RESTRAINT SHAPE AND SIZE NOMINAL DIAMETER AREA(in.) GYRATION, r(in.) I/r=100 I/r=200 I/r=300 I/r=400* Rods(all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 Rods(threaded at en ds on ly) 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Referen ce:NFPA 13, (2007) *Referen ce:NFPA 13, (2010) IT[r�JConstruction Products" Call our toll freenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneral information. SAMMYS' S 15 VisitlTW Buildex'sSAMMVSweb sitewww.sammysuperscrew.com forthe most currentproductand technical information. SAMMYS X-Press f orSeismic Restraint DESCRIPTION (SIDEWINDER) TEgrED ro SWXP35 FOR 3/8"ROD ui TE,p z �R\ MENSStructuralattachmentforinstallationof branch/end of lin erestraintusin g I �'3/8"threadedrod.Usedprimaril in purlin,bar joist,orothersteelstructural -•• Sc A\<;, t0 members.Thesefasteningsystemsprovideasecureandeconomicalattachment i swotDESI611 to the structure. COWRIE! C.D.E. & The SWXP35 model providesupperstructural attachmentin a ran geof steel thicknessesf roml6 ga.through 1/8".An expandablesleeveis included with eachfasten er,eliminating need forretaining nut. I 40 SPECIFICATIONS ' rz, Restrained PipeSize: Up to Schedule40 pipe 2"or less :'y9 Max Lengthof %i, i RestraintMaterial: See Maximum Horizon talLoad Tables below. i� U Maximum Angle: 45°fromhorizontal .7N . Material: CarbonSteel �� ScrewDescription: 1/4"-20X 1-1/8"with expandablesleevey Finish: Electro Zindcap&screw) f"r743, 13°9 I 04101._ Testing: BX Report#R-1362 nroper Listing: UL 203 as apipe hanger ® installation! UL203Apen din g cLISTEDus SELECTION CHART SAMMYS Sidewinders f orConcrete-Seismic Restraint ROD PART MODEL MIN MAX APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER THICKNESS THICKNESS QTY QTY The SWXP 35 must be in stalled 3/8" 8293957 SWXP35 16 ga. 1/8" SteelPurlinorBarioist 25 125 with UXPITTool(PartNo.8194910); pre-drilling required. PERFORMANCE TABLES Maximum Horizontal Loadsf or Restraint witW/r=100, 200,300,and400 RESTRAINT SHAPE AND SIZE NOMINAL AREA(in.2) LEAST RADIUS OF MAXIMUM ROD LENGTH FOR lir(ft) DIAMETER GYRATION, r(in.) I/r=100 lir=200 lir=300 I/r=400* 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 Rods (all thread) 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 Rods (threaded at ends only) 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Reference:NFPA 13, (2007) *Referen ce:NFPA 13, (2010) ITT Construction Products` S 16 SAMMYS® Call our tollfreenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneral information. Visit ITW B uildex'sSAMM VSweb site www.sammysuperscrew.com f orthe most currentproductand technical information. SAMMYS® DESCRIPTION/SUGGESTED SPECIFICATIONS Tapcon SammyScrew- A n ch ors The Con creteSammy is made using 5/16"Tapcon®Con creteScrews,perfectforHan gin gSprin klerspipes, ElectricalFixtureor HVAC Equipmentto cast in place con Crete,precastconcrete,andopenweb joist. The Con creteSammy is available in vertical moun tto accommodateall fastening situations. f orConcrete ADVANTAGES Installs into Sammy's f orConcrete Product Features Concrete Structures Eas two step process(Drill hole&drive Easily and Quickly! Sammy con cretean chor). iin, n,,, ,,_, J, 1/4"pre-drilled pilot hole required. AvailableCon cretelnstalIationToolavailablefor a onetool installationprocess. i n Vertical go° �A�oil e� a o0 i i a°o 9 VERTICALMOUNT11 �� ,D-. ��� � °4 b o oA o'. °d j0. -.i�p�� r°__5'd o°a4oC o 'e:171,;'` -°°aQ� •, o°� o° °a . cJ °opo°a G',._,' C ■°o 1. o17:d ou o01 p° ood+ .I °ter vd4oaa°O [ . a�°J OMIZ,p° 1 ITL WConstruction Products'" Call our tollfreenumber 800-387-9692 or visitwww.itwconstruction.ca forgeneral information. SAIVIIVIYS.. C 17 VisitlTW Buildex'sSAMMVSweb sitewww.sammysuperscrew.com forthe most currentproductand technical information. .7 SAMMYS f orConcrete APPLICATIONS APPROVALS / I SprinklerSystems See SelectionChartforitemswithapprovals. Pipes/Plumbing ElectricalLighting an dFixtures INSTALLATION INSTRUCTIONSVERTICAL MOUNT HVAC Equipmen tan dFixtures AA .::::::1-:,:.: :.:::::,::,..r...-:.: 7,.- — -- ,,,. i'. .ii:- -- -- Using an SDS 250 carbidetip bit or a HEX RECEIVERwith a #250 carbide ti ,irkii. tip bit,pre-drillthecon cretanemberto a depth of 2"with an electric .;;w: impact/drill seton impact mode. Afterpre-drilling has been completed,install the SLEEVET0OL overthe bit(thebit should remain in the drill),an din sertthe#14(black) nut driver(p/n8113910) in tothe oppositeen d. In sertthe con cretescrewin tothe n utdriver. Placetip of screwin tothe pre-drilled hole,turn impact/drillun itto drill mode an dbegin insertion When then utdriverspin sf reeon the screw, in stallationis complete.Stopan dremovedrill. 5. The con cretEscrewis readyto receivel/4",3/8",1/2",or metricall thread rod or bolt stock.(#14SW red n utdriver used with 1/2"screw) NOTE:Use a 1200 maximum RPMdrill forinstallation. NOTE:Don otinstall con cretEscrewswhile the drill un itis in impact mode—doing so will destroythe pullout f actorof the screw. SELECTION CHART i i SAMMYS Vertical Mount • Part#8113910 •Part#8114910 ROD PART ULTIMATE . TEST BOX CASE NUT SIZE NUMBER MODEL DESCRIPTION PULLOUT (LBS) LOAD QTY QTY DRIVE APPROVED (LBS) 3/8" 8059957 CST20 5/16x1-3/4" 2400 1475 25 125 Part# 8113910 ill . ) x� f t ITT Construction Products` S 18 SAMMYS® Call our tollfreenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneral information. Visit ITW B uildex'sSAMM VSweb site www.sammysuperscrew.com f orthe most currentproductand technical information. RING HANGERS 0.4wR4 Fig. 138R (Rod Threaded) Extension Split Pipe Clamp Size Range:3/8"through 3" Material:Malleable iron Finish:❑Plain or❑Zinc Plated(Hot-Dip Galvanized optional) Service:Recommended for non-insulated stationary pipe lines. '�-. Maximum Temperature:450°F ^ l Approvals:Complies with Federal Specification A-A-1192A(Type 12) WW-H-171-E(Type 25),ANSI/MSS SP-69 and MSS SP-58(Type 12). Features: • Rapid installation assured by hinged design and single closure screw. • When used with nipple this clamp is particularly adaptive for use on refrigeration or compressor piping subject to vibration. • Interior design provides firm grip on pipe. • Inside of ring tapered to prevent entrapment of condensed moisture. Ordering:Specify pipe size,figure number,name and finish. o A FIG. 138R: 0 I I DIMENSIONS (IN) • LOADS(LBS) • WEIGHT (LBS) 4,�� a 15 Pipe Size Max Load Weight Rod Size A B 3/S 0.10 13/16 _( Y2 0.13 7A 3/a 0.14 1 .1- .....viiiiij\,.......... ) 1 180 0.16 3/e 11/8 11A 0.22 15/s 11/2 0.24 17A6 2 0.31 111/s 21/2 300 0.60 1/z 21/8 3 0.74 27A6 PROJECT INFORMATION APPROVAL STAMP Project: ['Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.15 RISER CLAMPS 0.4.Nv.t6 Fig. 261 (Formerly Afcon Fig.400) Extension Pipe or Riser Clamp Size Range:3/4"through 24" Material:Carbon steel Finish:❑Plain,❑Hot-Dip Galvanized with Zinc Plated Bolts&Nuts, ❑Epoxy Coated or❑Painted. Service:For support of stationary steel pipe risers,cast iron pipe COus or conduit.This product is not intended for use with hanger rods. LISTED For this application refer to Fig.40 Riser Clamp,page 49. Maximum Temperature:Plain 650°F,Galvanized and Epoxy 450°F Note:Refer to Technical Data Section of the Pipe Hanger Catalog Approvals:Complies with Federal Specification A-A-1192A(Type 8) for cast iron soil pipe data. WW-H-171-E(Type 8),ANSI/MSS SP-69 and MSS SP-58(Type 8). L J��� 1 UL,ULC Listed(Sizes 11/2"-8"). II // g Installation:Clamp is fitted and bolted preferably below a coupling, I 1 y + hub or welded lugs on steel pipe.Bolt torques should be per industry l L 11 �\ t standards(see page 248).Clamp is designed for standard steel pipe O.D. \\ and this must be considered in sizing the riser for other types of piping. ( ( 0 ) :G Ordering:Specify pipe size,figure number,name and finish. l I. B iI • L FIG.261:DIMENSIONS(IN) • LOADS(LBS) •TORQUE (FT-LBS) •WEIGHT(LBS) Pipe Max G Bolt Torque Size Load Weight L Width Diameter C Diameter Values 3/a 220 1.1 8% 2% 1 1.1 31/8 11/4 1.6 10 31/2 3/a 3/s 21 11/2 250 1.6 101/43%/s 2 300 1.7 1 41/4 21/2 400 1.9 111/4 43/4 1/2 7A6 32 3 500 1.9 113/8 51/2 31/2 600 2.3 12/8 61/2 4 750 2.4 7 5 1,500 3.6 133/4 8 1/2 1/2 46 6 1,600 4.0 143/4 11/2 9 8 7.6 181/2 12 2,500 10 11.1 201/4 133/4 12 16.5 223/4 2 153/4 5/a 5/s 100 14 2,700 17.7 24 171/4 16 30.4 26 193/4 18 2,900 33.8 28 21/2 213/4 3/4 3A 150 20 35.0 30 233/4 24 3,200 82.0 363/4 3 30 1 '/s 190 PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ['Approved as noted Contractor: ['Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.18 Mechanical Anchoring Systems 3.3.8 KWIK Bolt 3 Expansion Anchor 3.3.8.1 Productdescription 3.3.8.1 Product description 3.3.8.2 Material specifications The KWIK Bolt 3(KB3)is a torque Guide specifications 3.3.8.3 Technical data controlled expansion anchor,which Torque controlled expansion anchor 3.3.8.4 Installation instructions provides consistent performance for shall be KWIK Bolt 3. KWIK Bolt 3 3.3.8.5 Or deringinformation a wide range of mechanical anchor anchors meet the description of Federal applications.This anchor series is Specification A-A 1923A, Type 4. The available in carbon steel with zinc Impact section anchor bears a length identification (dog point) electroplated coating,carbon steel mark embossed on the impact section with hot-dip galvanized coating,304 (dog point)of the anchor identifying the stainless steel and 316 stainless steel anchor as a Hilti KWIK Bolt 3. Nut — versions.The threaded stud version of the anchor is available in a variety of Carbon steel KWIK Bolt 3 anchors have Washer— diameters rangingfrom 1/4-to 1-in. a carbon steel anchor body,carbon depending on the steel and coating steel nut and carbon steel washer. Anchor type.Applicable base materials include Anchor body,nut and washer have zinc thread normal-weight concrete, structural plating confor mingto ASTM B633 with lightweight concrete, lightweight a minimum thickness of 5 pm. • concrete over metal deck,and AISI Type 304 stainless steel KWIK Bolt Anchor _ grout filled concrete masonry. 3 anchors have an anchor body,nut body Product features and washer That conform to AISI Type 304. The expansion wedges confor m Expansion • Length identification code element — to either AISI Type 304 stainless steel (wedges) facilitates quality controland or either AISI Type 316 stainless steel. inspection after installation. Expansion — • Through fixture installation and AISI Type 316 stainless steel KWIK Bolt cone 3 anchors have an anchor body,nut variable thr eadlengths improve productivity and accommodate and washer That conform to AISI Type Listings/Approvals various base plate thicknesses. 316. The expansion wedges confor m (International Code Council) to AISI Type 316 stainless steel. ICC-ES • Raised impact section(Dog Point) ESR-2302 ICC ES(International Code Council) prevents threaddamage during Hot-dip galvanized KWIK Bolt 3 ESR-1385 Grout-filled concrete masonry installation. anchors have a carbon steel anchor City of Los Angeles • Anchor size is same as drill bit size body,carbon steel nut and carbon steel Research Report No.25577 washer.Anchor body,nut and washer Research Report No.25577M masonry for easy installation.For temporary FM(Factory Mutual) applications anchors may be driven have zinc plating confor mingto ASTM Pipe Hanger Components for into drilled holes after usage. A153 with an average thickness of 53 Automatic Sprinkler for 3/8 through 3/4 pm.The expansion wedges conform to UL LLC • Mechanical expansion allows either AISI Type 304 stainless steel or UL 203 Pipe Hanger Equipment for Fire immediate load application. yp Protection Services for 3/8 through 3/4 either AISI Type 316 stainless steel. Qualified under an NQA-1 Nuclear • Can be installed with innovative Quality Program Hilti TorqueBar(seen below)in ice' €LAGDOS U Fo conjunction with Hilti impact APPAOVO] F tools. The first impact tool *Please refer to the reports to verify that the type approved by ICC-ES to install and diameter specified is included an expansion anchor. Independent code evaluation IBC®/IRC®2015 IBC®/!RC"2012 IBC®/IRC®2009 IBC®/IRC®2006 IBC®/IRC®2003 S-TBtorquebar A18/A22 impact tool 338 Hilti,Inc.(US)1-800-879-8000 I www.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed.17 Mechanical Anchoring Systems KWIK Bolt 3 Expansion Anchor 3.3.8 3.3.8.2 Material specifications Carbon steel with electroplated zinc All carbon steel KWIK Bolt 3 and Rod Coupling Anchors,excluding the 3/4 x 12 and 1-inch diameter sizes,have the tensile bolt fracture loads shown in table 1. All carbon steel 3/4 x 12 and 1 inch diameter sizes and carbon steel KWIK Bolt 3 Countersunk anchor bodies have mechanical properties as listed in table 1. Carbon steel anchor components plated in accordance with ASTM B633 to a minimum thickness of 5 pm. Nuts conform to the requirements of ASTM A563,Gr adeA,Hex. Washers meet the requirements of ASTM F844. Expansion wedges aremanufactured fr omcarbon steel,except the following anchors have stainless steel wedges: •All 1/4-inch diameter anchors • 3/4x12 •All 1-inch diameter anchors •All KWIK Bolt 3 Countersunk Carbon steel with hot-dip galvanized plating Anchor bodies manufactured fr omcarbon steel have the tensile bolt fracture loads shown in table 1. Carbon steel anchor components have an average zinc plating thickness greater than 43 pm according to ASTM A153, Class C. Nuts conform to the requirements of ASTM A563,Gr adeA,Hex. Washers meet the requirements of ASTM F844. Stainless steel expansion wedges aremanufactured fromeither AISI Type 304 or Type 316. Stainless steel 3.3.8 Anchor bodies smaller than 3/4-inch,excluding all KWIK Bolt 3 Countersunk, ar epr oducedfr omAISI Type 304 or Type 316 stainless steel having the bolt fracture loads shown in table 1. Anchor bodies 3/4-inch and larger,and all stainless steel KWIK Bolt 3 Countersunk anchor bodies,areproducedfrom AISI Type 304 or Type 316 stainless steel having the mechanical properties shown in table 1. Nuts meet the dimensional requirements of ASTM F594. Washers meet the dimensional requirements of ANSI B18.22.1, Type A,plain. Stainless steel expansion wedges for AISI Type 304 aremade fromeither AISI Type 304 or Type 316. Stainless steel expansion wedges for AISI Type 316 anchors ar emade fr omtype 316. All stainless steel nuts and washers for AISI Type 304 or Type 316 anchors ar emanufactured fr omAISI Type 304 or 316, respectively. Table 1 - Hilti KWIK Bolt 3 Bolt fracture load(lb)' Nominal anchor diameter in. Carbon steel Hot-dip galvanized Stainless steel 1/4 2,900 no offering 2,900 3/8 7,200 no offering 7,200 1/2 12,400 12,400 12,400 5/8 19,600 19,600 21,900 3/4 28,700 28,700 fats>-76,fYa>-642 1 fata>-88,fYa>-752 no offering fats>-76,fYa>-642 1 Bolt fracture loads are deter mined by testing in a universal tensile machine for quality contr olat the manufacturing facility.These loads are not intended for design use.See tables 4 and 12 for the steel design strengths of carbon steel and stainless steel, respectively. 2 All 3/4-in.stainless steel,3/4x12 carbon steel,all 1-in. carbon steel and all 1-in. stainless steel material strengths specified by the tensile and yield strengths expressed in(ksi). Bolt fracture loads not applicable for these models. Hilti,Inc.(US)1-800-879-8000 I www.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Cor p.1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed.17 339 Mechanical Anchoring Systems 3.3.8 KWIK Bolt 3 Expansion Anchor 3.3.8.3 Technical data 3.3.8.3.1 ACI 318-14 Chapter 17 design The load values contained in this section ar eHilti Simplified Design Tables. The load tables in this section were developed using the Strength Design parameters and variables of ESR-2302 and the equations within ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.7. Data tables from ESR-2302 ar enot contained in this section,but can be found at www.icc-es.org or at www.hilti.com. Allowable Stress Design or ASD technical infor mation and data tables can be found at www.hilti.com. MS Ise 1=1' , dh 1 1 E ISI dbit Figure 1 - KWIK Bolt 3 installation Table 2- Hilti KWIK Bolt 3 specifications Setting Nominal anchor diameter _infor mation _ Symbol_ Units _ 1/4 3/8 1/2 5/8 3/4 1 Dr ill bit dia. du, in. 1/4 3/8 1/2 5/8 3/4 1 Minimum nominalh in. 1-3/4 2-3/8 2-1/4 3-5/8 3-1/2 4-3/8 4-1/4 5-5/8 4-5/8 6-3/8 embedment "°`" (mm) (44) (60) (57) (92) (89) (111) (108) (143) 117 162 Minimum effectiveh in. 1-1/2 2 2 3-1/4 3-1/8 4 3-3/4 5 4 5-3/4 embedment e' (mm) (38) (51) (51) (83) (79) (102) (95) (127) (102) (146) in. 2 2-5/8 2-5/8 4 3-7/8 4-3/4 4-1/2 5-3/4 5 6-3/4 Minimum hole depth ha (mm) (51) (67) (67) (102) (98) (121) (114) (146) (127) (171) Fixture hole dia. dh in. 5/16 7/16 9/16 11/16 13/16 1-1/8 Anchor length f See or der ingnfor mation Installation torque ft-lb 4 20 40 60 110 150 concrete Tine (Nm) (5) (27) (54) (81) (149) (203) Installation torque ft-lb 4 15 25 65 120 not masonry Tine (Nm) (5) (20) (34) (88) (163) recommended Wrench size in. 7/16 9/16 3/4 15/16 1-1/8 1-1/2 1 For mor einfor mation,see ESR-1385 and section 3.3.8.3.3.Approval value are for carbon steel anchors only. 340 Hilti,Inc.(US)1-800-879-8000 I www.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed.17 Mechanical Anchoring Systems HDI-P Drop-in Anchor 3.3.12 3.3.12.1 Product description 3.3.12.1 Product description The HDI-P drop-in anchor is an • HSD-G 3/8 setting tool with hand 3.3.12.2 Material specifications internally threaded,flush mounted guard leaves mark on flange when 3.3.12.3 Technical data expansion anchor for solid and anchor is set properly to enable 3.3.12.4 Installation instructions hollow concrete. inspection and verification of proper expansion 3.3.12.5 Ordering information Product features Guide specifications • Optimized anchor length to allow Expansion anchor shall be flush or reliable fastenings in hollow core panels,precast plank and post shell type and zinc plated in accordance tensioned slabs with ASTM B633,SC 1, Type III. • • Shallow drilling enablesfast Anchors shall be Hilti HDI-P anchors as • installation supplied by Hilti. • Lip provides flush installation, Install shell or flush type anchors in consistent anchor depth and easy holes drilled with Hilti carbide tipped drill rod alignment bits. Install anchors in accordance with manufacturer's instructions. Listings/Approvals 3.3.12.2 Material specifications FM(Factory Mutual)for 3/8-in.model The HDI-P is manufactured from mild carbon steel,which is zinc plated for 44> corrosion protection in accordance with ASTM B633,SC 1, Type III. APPROVED 3.3.12.3 Technical data Table 1 - Hilti HDI-P loads in normal-weight concrete and hollow core concrete panels Nom. Ultimate loads,lb(kN) Allowable loads,lb(kN)3 Nominal bit f =4,000 psi concrete Hollow core12 lc=4,000 psi concrete Hollow core" anchor Length dia. diameter in.(mm) in. Tension Shear I Tension Shear Tension Shear Tension Shear 1/4 5/8 (15.9) 3/8 1,430 (6.4) 1,870 (8.3) 1,550 (6.9) 2,275 (10.1) 285 (1.3) 375 (1.7) 310 (1.4) 455 (2.0) 3/8 3/4 (19.1) 1/2 1,900 (8.5) 3,000 (13.3) 2,100 (9.3) 4,000 (17.8) 380 (1.7) 600 (2.7) 420 (1.9) 800 (3.6) 1/2 1 (25.4) 5/8 3,000 (13.3) 6,075 (27.0) 3,110 (13.8) 5,495 (24.5) 600 (2.7) 1215 (5.4) 620 (2.8) 1,100 (4.9) 1 The Admissible Anchor Location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm Admissible Anchor Location. 2 Minimum compressive strength of hollow core panels is 7,000 psi at the time of installation. The minimum thickness"t"is 1-3/8 inches. 3 Allowable loads calculated with a 5:1 factor-of-safety. 3.3.12 Figure 1 - Installation of Hilti 3.3.12.4 Installation instructions HDI-P in hollow core concrete Installation Instructions For Use(IFU)are included with each product package.They can also be viewed or downloaded online 111 110 at www.hilti.com(Canada).Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance.Training is available on request.Contact Hilti Technical Services for applications and conditions not addressed in the IFU. Admissible anchor location Length 3.3.12.5 Ordering information HDI-P anchor Setting tools for HDI-P anchors Description Bit diameter Qty/box Description HDI-P 1/4 3/8 100 HST-P 1/4 Hand Setting Tool HDI-P 3/8 1/2 100 HST-P 3/8 Hand Setting Tool HDI-P 1/2 5/8 50 HSD-G 3/8Hand Setting Tool with hand guard HST-P 1/2 Hand Setting Tool Hilti,Inc.(US)1-800-879-8000 I www.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed.17 387 Bulletin 014 Rev. P CO ® Model F 1 F R Series Reliable Qu is kResponse 0 Glass BulbSprinklersDDCD Model F1FR56 Sprinkler Types = , Standard Spray Upright s Standard Spray Pendent Ili Conventional Upright/Pendent `- Vertical Sidewall t ' i, _--ft Horizontal Sidewall a 4 Model F1FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent - Horizontal Sidewall �`'11111 , • ;F_ Model F1FR56 Concealed Sprinkler Types "9 N Standard Spray Pendent , yew _ ,% Model F1FR42, F1FRXLH & F1FR28 Sprinkler _� Types Standard Spray Upright Vertical Sidewall Horizontal Sidewall Recessed Standard Spray Pendent Pendent/F1/F2 Model Fl FR40 Sprinkler Types `' Standard Spray Pendent / '�� < .,`f t ; Model F1FR42, F1FR40, F1FRXLH & F1FR28 .t � Recessed Sprinkler Types ;, �,• .}:, '= Standard Spray Pendent �' :, ., ModeIF1 FR56LL&F1FR42LL LowLead Sprinkler Recessed Concealed Recessed Types Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead Content � L , Listing &Approvals ' 11• Kow _ The following organizations provide Listings or Approvals \�', is for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on XLH Upright XLH Pendent XLH Recessed specific listings and approvals applicable to each sprin- PendenlF1/F2 kler. Product Description — 1. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. Reliable Model F1FR series sprinklers 2. FM Approvals (FM) are quick-response automatic sprin- ' 3. Loss Prevention Certification Board(LPCB) klers with a glass bulb thermal element. 4. VdS Schadenverhutung GmbH (VdS) Model F1FR series sprinklers are Stan- 5. Underwriters Laboratories Inc. and Underwriters dard Spray sprinklers, with the excep Laboratories of Canada Certified for Health Effects tion of the Model F1FR56 Conventional XLH Recessed to NSF/ANSI Standard 61 Annex G (ULH) sprinkler which is an Old-style/Conven- PendentFP tional sprinkler. 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- The Model F1FR Series automatic sprinklers utilize a 3.0 CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) mm frangible glass bulb.These sprinklers have demonstrat- (EC) ed response times in laboratory tests which are five to ten UL Listing Category times faster than standard response sprinklers. This quick Sprinklers,Automatic&Open(VNIV) response enables the Model F1FR Series sprinklers to apply Quick Response Sprinkler waterto afirefasterthan standard-response sprinklers of the same temperature rating. The glass bulb consistsof an accuratelycontrolled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid Model F1FR Series sprinklers must be installed with the in both the liquid and vapor phases. The vapor phase can Reliable sprinklerinstallation wrench identified in the Design be seen as a small bubble.As heat is applied, the liquid and Installation Information table in this Bulletin. Any other expands, forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leaktight sprinklerjoint uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended ute the discharging water. installation torque may cause leakage or impairment of the Model Fl FR Series sprinklers provide a wide range of op- sprinkler. tions where quick-response, glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal Model F1FR Series Recessed sprinklers are to be installed sidewall, and vertical sidewall deflectors as shown in Fig. 1, Fig. 2,or Fig.3,as applicable to the spe- • K-factors of 2.8 (40 metric), 4.0(57 metric), 4.2(60 cific model being installed.The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons • Flush, recessed, and concealed installations that are permitted to be used with each Model Fl FR Series See the Design and Installation Information table in this Recessed sprinkler.The use of anyotherrecessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model Fl FR series sprinkler configurations. Concealed Sprinklers Model F1FR Recessed Pendent and Recessed Horizon- Model F1FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig.4 or Fig.5,as applicable to the Model Fl, F2, or FP recessed escutcheons. See the Re- selected cover plate. Model F1FR56 Concealed Pendent cessed Escutcheon Data table in this Bulletin for listing and and Model F1 FR56LL Concealed Pendent sprinklers have approval information with each specific Model F1FR series a factory-installed Model CCP cup. A protective cap is in- sprinkler. Model Fl and F2 recessed escutcheons,shown in stalled at the factory that should remain on the sprinkleruntil Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on (19mm) and 1/2-inch (12.7mm)of adjustment, respectively. the sprinkleruntil the coverplate is installed.The concealed Model FP recessed escutcheons, shown in Fig. 2, provide a sprinkler assemblies are completed by the installation of a 1/2-inch (12.7mm)threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1FR56 Concealed Pendent and Model F1FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP coverplates.A standard profile Model CCP cov- ment. A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch(12.7mm)of provides either 1/2-inch (13mm)or 5/8-inch (8mm)of cover coverplate adjustment. In addition,a low profile Model CCP adjustment. Do not install Model F1FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.0mm) of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model Fl FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The proved cover plate options. Model RC1 wrench is used to engage the sprinkler wrenching Application surfaces and to install the sprinkler in the fitting. Remove the Model F1FR Series sprinklers are intended for use in protective capto installthesprinkler,then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov- Data Sheets, and the requirements of the Authority Hav- ing thewrencllromthesprinkler/cup assembly,careshould be ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating, deflector style, and sprinkler type are other part of the sprinkler/cup assembly. Installation is corn- in accordance with the requirements of the applicable pleted by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the coverplate onto the cup. Final adjustment is made F1FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirt flange makes full their listings and approvals, as well as the information contact withtheceiling.Coverplateremoval requires turningthe provided in this Bulletin. coverplate in the counterclockwise direction.Afterinstallation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro coverplateand ceiling and thatthefourcupslotsareopenand tective caps to minimize bulb damage during shipping,han- free from anyairflowimpediment tothespaceabove. dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers.The use of any concealed cover place. Remove the bulb protectoratthe time when the sprin plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model F1FR56 Concealed Pendent and Model Fl FR56LL of the bulb protectorbefore this time may leave the bulb vul- Concealed Pendent sprinklers or the use of the Model CCP nerable to damage. Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with clasp by hand. Do not use tools to remove bulb protectors. which it is not specifically listed my prevent good fire pro tection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar)- 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal Orifice Sprinkler Listings K-factor Deflector/ Installation Approval Model Diameter SIN and Orientation Height Wrench Notes Approvals US Metric inches mm inches mm Pendent 2.25 57 Dor W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D or W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 Dor W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 Dor W2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D or W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 Dor W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 Dor W2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 D or W2 RA1423 cULus _ 1,2 _ Pendent 2.25 57 Dor W2 RA1414 cULus, FM, 1,2,3,4 LPCB,VdS, EC Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, 1,2,3,4 LPCB,VdS, EC F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D or W2 RA1425 cULus, FM, 1,2,3,4 LPCB,VdS, EC "Conventional 2.25 57 Dor W2 RA1475 LPCB,VdS, EC 4 (Pendent or Upright)" Pendent 2.25 57 Dor W2 RA1415 cULus, ULH 1 F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 RC1 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 D or W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 GFR2 RA1435 cULus, FM 8 Sidewall F1FR56 5.6 80 1/2 15 Vertical Sidewall 2.25 57 D or W2 RA1485 cULus, FM, 1,2,3,9 (Pendent or Upright) LPCB (1)cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. (5)VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C)temperature rated sprinklers only.VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm)of adjustment. (7)cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches(102mm to 305mm). FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8)cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9)The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector/ 100°F (38°C) Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C) Max. Model Temp. _ Temp. —286°F Ambient Temp. Orientation 135°F(57°C) 155°F(68°C) 175°F (79°C) 200°F(93°C) 286°F(141°C) Temp. Temp. Rating Temp. Rating Temp. Rating Temp. Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus -- Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS -- Pendent cULus F1FR42 Recessed Pendent cULus -- Upright cULus F1FR42LL Pendent -- cULus, ULH -- Recessed Pendent -- cULus, ULH -- Pendent cULus F1FRXLH Recessed Pendent cULus -- Upright cULus Pendent cULus, FM, LPCB,VdS, EC Recessed Pendent cULus, FM, LPCB,VdS, EC -- F1FR56 Concealed Pendent* cULus cULus,VdS,EC cULus -- Upright cULus, FM, LPCB,VdS, EC "Conventional (Pendent or Upright)" LPCB,VdS, EC Pendent -- cULus, ULH -- F1FR56LL Recessed Pendent -- cULus, ULH -- Concealed Pendent" -- cULus, ULH -- Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal cULus, FM Sidewall F1FR56 Vertical Sidewall (Pen cULus, FM, LPCB dent or Upright) * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C)temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model Fl Model F2 Model FP Model Orientation (Fig.1 &3) (Fig.1 &3) (Fig.2) SIN 3/4-inch(19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB,VdS, cULus, FM, LPCB, cULus,VdS, EC RA1414 EC VdS, EC F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. 2 1/4"HOLE DIA. J [57.2mm] 1 15/16"DIA J [49.2mm] L- --I 1" X 1/2" REDUCER TURN COLLAR IT y UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS \ \ / 11 FACE OF FITTING TO FACE OF CEILINGGDIMENSION \II / F1 ESCUTCHEON AT MAXIMUM RECESS = 1'(25.4mm] SII L J �� AT MINIMUM RECESS = 3/8'[9.Smm] Cl ESCUTCHEON F2 ESCUTCHEON 3/4[19mm] AT MAXIMUM RECESS = 3/4"[19m m ADJUSTMENT i� AT MINIMUM RECESS = 3/8[9.5mm] F2 ESCUTCHEON ro 03SVEI IIII ///A 1 1/2[12.7mm] t O i `ii ADJUSTMENT 1 7E1! 7f,1 �� Fl ESCUTCHEON I1/8" A AT MAXIMUM RECESS = 7/8"[22.2 mud IIP L) [3.2,77,7 /AT MINIMUM RECESS = 1-5/8'141.3mm] F2 ESCUTCHEON `- 11 U:v AT MAXIMUM RECESS = 1-1/8'[28.6mm] $ `' AT MINIMUM RECESS = 1-5/8[41.3mm] 2 27/32"DIA. [72.2mm] Fig. 1 ModelF1FR56,F1FR56LL,F1FR42F1FR4OF1FR42LL,F1FRXLH&F1FR28 Recessed Pendentsprinkler withModel F 1 or F2 escutcheon L----7----7---==;=1--Z-- _—I I I 1" X 1/2" REDUCER 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP L J CEILING �_" =''� FACE OF FITTING IIIA!II ®�St� �� TO FACE OF CEILING IIIIIII ;! DIMENSION �s j 1!!i� r!!!1 is AT MAXIMUM RECESS = 1-1/2 738mm] - !w IIb I AT MINIMUM RECESS = 1725.4mm] ty, II 1 II,' 111 ,i�� 1 AT MAXIMUM RECESS = 9/16714.3mm] %2"[12.7mmJ '�!„!�` AT MINIMUM RECESS = 1725.4mm] ADJUSTMENT ,,,. .,,, 3 1/4" DIA. t [82.6mm] Fig.2 Model F1FR56,F1FR56LL,F1FR42F1FR4OF1FR42LL,F1FRXLH&F1FR28 Recessed Pendentsprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON j/ A AT MAXIMUM RECESS = 1"[25.4mm] Fl ESCUTCHEON AT MINIMUM RECESS = 3/879.5mm] 44 F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8[34.9mm] AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 2-1/16'[52.4mm] AT MINIMUM RECESS = 3/8 79.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8[41.3mm] 2 1/4" HOLE DIA. 1/8» AT MINIMUM RECESS = 2-1/16[52.4mm] [57.2mm] ` [3.2mm] 1" X 1/2" REDUCER _Rn►i f r-J- (`__ m `I (1) ,�1114 -f1 III, 1 15/16" DIA.;) Iµ IIIIIIIII IIIII �JIi I 4 -12 [49.2mm] 7 ill II IIS 1.I�I [101.6m CEILING T SmmJ I III IIIIIIIII II r ; 2 27/32" D/A. TO "' [72.2mm] DEFLECTOR ti L_i1� LJl L_J--�L-- Ain II f 1 TURN COLLAR UNTIL TIGHT AGAINST �U SPRINKLER WRENCH BOSS. F1 ESCUTCHEON 3/4"[19mm] ADJUSTMENT F2 ESCUTCHEON 1/27-12.7mm] ADJUSTMENT 013FGOJE RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 ModelF1FR56 Recessed Horizontal Sidewallsprinkler with ModelF1 or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW iii n _I_ r - 2 5/8" DIA. 2 5/16" DIA — HOLE IN CEILING CLIP ,>t=—=H--- , III ®�.���IIQp ? 1 1/2" MAX. ��������� I illi MI��I i iiiiii: ill �VtFACE OF FITTING 1 TO FACE OF CEILING � �1 l��I 1/////// DIMENSION CEILING ,/1� .. ���I \ i 1/2" MAX. 1111111W‘ ' 15/16" COVER ADJUSTMENT COVER PLATE ASSEMBLY3 5/16" DIA. SPRINKLER / CONCEALED, 1/2" ADJUSTMENT 017FGO1A Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendentsprinkler with standard depth 1/2-inch(12.7mm)adjustment-ModeICCPcoverplate 6. 1" x 1/2" REDUCING TEE OR ELBOW J ]I + }} ill � 1- 2 5/8" DIA. 2 5/16" DIA — HOLE IN CEILING IL:- ---7_:-____-- --- CUP ';=i—sN ', Iriwl I�II� 1 1/2 MAX. FACE OF FITTING ',/7/1''',/7/77ATO FACE OF CEILING CEILING 5/16" MAX. 3/4" COVER ADJUSTMENT COVER PLATE / f ASSEMBLY 3 5/16" DIA. SPRINKLER CONCEALED, 5/1 6" ADJUSTMENT 01 7Fca2n Fig.5-Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch(8,0mm)adjustment-ModelCCPcoverplate Maintenance Material Data The Model F 1 FR Seriessprinklers should be inspectedand the sprinkler system maintained in accordance with NFPA Frame: DZR Brass,QM Brass,or Low Lead Brass 25. Do not clean sprinklers with soap and water,ammoniaor Deflector: CDA Alloy 220, 260,or 510 anyothercleaning fluids. Remove dust by using a soft brush Load Screw\Pintle: CDA Alloy 360 or 544 or gentle vacuuming. Replace any sprinklerwhich has been Cup: CDA Alloy 651 or 693 painted(otherthan factory applied)or damaged in any way. Washer: Nickel Alloy 440or 360, coated with PTFE A stock of spare sprinklers should be maintained to allow Adhesive Tape quick replacement of damaged or operated sprinklers. Bulb: Glass Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate') Ordering Information Bronze Brass Chrome Specify: Chrome Plated Chrome Plated White 1. Sprinkler Model: [F1FR28][F1FR40][F1FR42] Polyester Coated(4x5x6) White Painted Special Application Finishes [F1 FR42LL][F1 FRXLH][El FR56][F1 FR56LL] Sprinkler Escutcheon Cover platem 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Electroless Nickel Electroless Nickel Bri ht Brass Pendent][Upright][Conventional][Horizontal Sidewall] PTFE') PTFE g [Recessed Horizontal Sidewall][Vertical Sidewall] Bright Brasso) Bright Brass Black Plating Black Plated Black Plated Black Paint 3. Sprinkler threads: [1/2 inch NPT][ISO 7-R1/2] Black Paint(2)(6) Black Paint Off White 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F Off White(2)I6) Off White Satin Chrome (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] Chrome Dull Chrome Dull 5. Sprinkler Finish (1) Other finishes and colors are available on special order. Consult the 6. Escutcheon Model: [F1][F2][FP] factory for details.Custom color painted sprinklers may not retain their UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, 7. Escutcheon Finish (where applicable) unless specified otherwise. 8. Cover plate Model: [standard profile CCP 1/2-inch (2) cULus Listed only. (12.7mm) adjustment][low profile CCP 5/16-inch (3) 200°F(93°C)maximum. (4)cULus listed"corrosion resistance" applies to SIN Numbers RA1435 (8.0mm) adjustment] (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and 9. Cover plate Temperature Rating: [135°F(57°C)for use RA1415(Pendent)in standard black or white.Corrosion resistance in with Ordinary Temperature sprinklers][165°F (74°C) otherpolyestercolors is available upon request. for use with Intermediate Temperature sprinklers] (5) FM Approvals finish as"Polyester coated"applies to SIN Number 10. Cover plate Finish RA1414,RA1435 and RA1425 in standard blackor white. (6)LPCB and VdS Approved finish applies only to RA1425,RA1414,RA14 18 (VdS)and RA1475. Note:When Model F1FR Series Recessed sprinklers are ordered,the (7)cULus listed Corrosion Resistant sprinklers and escutcheons are packaged separately. 7. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinklercomponents. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipmentpresented in thisbulletinistobe installed in accordance withthelatestpublished Standardsof the NationalFireProtection Association,Factory Mutual Research Corporation,or other similarorganizations and also with the provisions of governmental codes or ordinances wheneverapplicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. i� Recycled ( ) Sales Offices Paper Reliabid 880000 848431 60515881 Sales Fax Revision lines indicate updated or new data. (914)829 2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.11 /17 P/N9999970300 ES-A-C400/C400N/C400Z For Fire Protection Applications Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative LEAD FREE ColtTM Series C400 (Colt 400), C400N (Colt 400N), C400Z (Colt 400Z) • Reduced Pressure Zone Assemblies C400 0SY _ .. (Colt 400) Sizes: 21/2" - 10" ,E.* i (65- 250mm) r • j .a d. a • C400NBFG (Colt 400N) � t Features The Colt C400, C400N, C400Z Reduced Pressure Zone Assembliesprovide protection to the potable water system from contamination in accordance with • Extremely Compact Design national plumbing codes.The Colt C400, C400N, C400Z are normally used in • 70% L ighterthan Traditional health hazard applications for protection against backsiphonage, backpressure Designs and the fouling of either check valve.The Colt C400,C400N,C400Z features • 304 (Schedule 40) Stainless Steel LeadFree"construction to complywith LeadFree*installation requirements. Housing&Sleeve Specifications • Groove Fittings Allow Integral Pipeline Adjustment The Colt C400, C400N, C400Z Reduced Pressure Zone Assembliesshall consist of two independent Link Check modules,a differential pressure relief valve • Patented L inkCheck Provides located betweenand below the two modules,two drip tight shutoffvalves,and LowestPressure Loss required test cocks.L inkCheck modules and relief valve shall be contained • Unmatched Ease of Serviceability within a sleeve accessible single housing constructedfrom 304 (Schedule Available with Grooved Butterfly 40) stainless steel pipe with groove end connections.L inkChecks shall have • reversible elastomerdiscs and in operationproduce drip tight closure against Valve Shutoffs the reverse flow of liquid caused by backpressure or backsiphonage. Lead Free* • May be Used for Horizontal or N Reduced Pressure Zone Assemb liesshall be constructed using Lead Free* Pattern Installations materials.It shall comply with state codes and standards,where applicable, • Replaceable Check Disc Rubber requiring reduced lead content.Assemblyshall be Colt C400, C400N, C400Z as manufactured by the Ames Company. *The wetted surface of this product NOTICE contacted by consumab lewater contains less than 0.25%of lead by weight. The information containedherein is not intended to replace the full product installation and safety information available or the experience of a trained product A WARNING installer.Youarerequired to thoroughly read all installation instructions and product safety information before beginning the installation of this product. It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing,in the United States.Before installing standard material prod- uct,consult yo ur local water authority,building and plumbing codes. AmesFire&Waterworks productspecifications in U.S.customaryunitsand metric are approximate and are provided for reference only.For precise measure- ments,please contactAmesFire&Waterworks Technical Service.AmesFire&Waterworks reserves th erigh So ch angeor modifyproductdesign,construction, - specifications,or materials with oupriornotice and with ouincurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. A WATTS Brand Configurations Pressure — Temperature • Horizontal Terrperature Range:33°F- 140°F (0.5°C-60°C) • "Z" patternhorizontal Maximum WorkingPressure:175psi (12.1 bar) • "N" patternhorizontal Note:When installing a drain line on Series C400 backflow preventer use 400/500 air gap.See ES-A-AG/EL/TC for additional information. Materials • Housing&Sleeve:304 (Schedule 40) Stainless Steel Available Models • Elastomers: EPDM,Silicone and Buna'N' Suffix: • L inkChecks:Noryr, Stainless Steel NRS- non-rising stem resilient seated gate valves • Check Discs: Reversible Silicone or EPDM OSY- UL/FMoutside stem and yoke resilient seated • Test Cocks:Bronze Body Nickel Plated gate valves • Pins& Fasteners: 300 Series Stainless Steel BFG- UL/FMgrooved gear operatedbutterfly valves with tamperswitch • Springs:Stainless Steel *OSY FxG- Flanged inlet gate connection and grooved outlet gate connection NoryP is a registered trademark of SABIC Innovative Plastics-m. *OSY GxF - Grooved inlet gate connection and flanged outlet gate connection Approvals *OSY GxG- Grooved inlet gate connection and grooved •Approved by the Foundation for Cross-Connection Control outlet gate connection and Hydraulic Research at The Unversityof Southern Available with grooved NRS gate valves- consult factory" California(FCCCHR-USC) Postindicator plate and operating nut available-consult factory* Excluding 6" Z Pattern configuration *Consult factory for dimensions •AWWA C551-92 For additional approval information please contact the factory or visit our website at www.amesfirewater.com **��pSSIFj�� ** -----\0 ei® c ® us ® (NSF C US Approved __ to 1013 B64.4 (**BFG&OSY Only) Certified Dimensions — Weights ,4:0-� =� Caen — iii iii (open) IUi ^� _ A A , __ _. , h • _ _ oI .„, . . . ��uuiIItF-- I� t H - .II-:ni3 A G P C400,C400N,C400Z SIZE(DN) DIMENSIONS WEIGHT A C(OSY) C(NRS) D G H I J M P C400 C400N NRS OSY NRS OSY in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 212 65 303/4 781 16/ 416 93/a 238 612 165 291/6738 2112 546 151/2 393 813/6 223 211/4 540 9/16 234 118 54 128 58 126 57 136 62 3 80 313/4 806 18% 479 101/4 260 611/6 170 301/4 768 221A 565 17% 435 93/6 233 23 584 10/2 267 134 61 148 67 147 67 161 73 4 100 333/4 857 223/4 578 12%6 310 7 178 355/8905 2311 597 1812 470 915/6 252 2614 667 113/6 284 164 74 164 74 187 85 187 85 6 150 4312 1105 301%a 765 16 406 8112 216 44%1137 351/4 895 233/6 589 131/6 332 341/4 870 15 381 276 125 298 135 317 144 339 154 8 200 493/4 1264 373/4 959 1915/6 506 911/6 246 541/81375 401/2 1019 277/6 697 1511/6 399 367/8 937 173/6 437 441 200 483 219 516 234 558 253 10 250 573/4 1467 453/4 1162 2313/6 605 113/6 285 66 1676 491/2 1257 321/2 826 175/6 440 441/2 1124 20 508 723 328 783 355 893 405 950 431 Dimensions — Weights I. f ' ai AP if IF i M lie I o XMN L CID, L RllitiS 0014_ H p G C400NBFG/C400ZBFG SIZE(DN) DIMENSIONS WEIGHT G H I J M P C400N,C400Z in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 21/2 65 23 584 23 584 151/2 394 91/2 241 193/4 502 1111/46 300 67 30 3 80 24 610 24 610 165/6 414 101/6 256 211/4 540 121/8 308 70 32 4 100 355/8 905 355/8 905 173/6 437 1015/6 279 231/2 597 12% 321 87 39 6 150 351/4 895 351/4 895 201/2 521 131/2 343 271/4 692 15 382 160 73 A A l IL® 1> IL® [ imir ■; ommn 1114. ii � I IFI1412 21 , NLEI .w. .1 fnl � t■1 I r11\,_„,- RpiII: % if gma Ii MEM: bd I A p C400 BFG SIZE(DN) DIMENSIONS WEIGHT A C D P m. mm in. mm in. mm in. mm in. mm lbs. kgs. 4 100 29 737 73/4 197 6% 162 91/2 241 66 30 6 150 361/2 927 911/46 246 7'/6 189 14% 362 122 55 Capacity - C400 B FG 4" (100 mm) 6" (150 mm) psi ServiceFlow Rated Flow *ULRated Flow psi ServiceFlow Rated Flow *ULRated Flow 25 16 20 14 N N 12 o z 15 , z 10 0 0 \ o 0 8 a cc 10 - a cc 6 s s 5 _ 4 2 0 0 0 100 200 300 400 500 600 700 800gpm 0 200 400 600 800 1000 1200 1400 1600gpm 0 380 760 1140 1520 1900 2280 2680 30401pm 0 760 1520 2280 3040 3800 4560 5300 6060 1pm 7.5 13 fps 7.5 12 fps Capacity Flow capacitychart identifies valve performance based upon rated water velocity up to 25fps • Service Flow is typicallydetermined by a rated UL/FM Certified Flow Characteristics velocity of 7.5fps based upon schedule 40 pipe. N&Z Flow characteristics collected using butterfly shutoffvalves. • Rated Flow identifies maximum continuous duty performance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not Horizontal N - Pattern Z- Pattern recommended for continuous duty. • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 10fps. 21/2" (65mm) 6" (15Omm) psi ServiceFlow Rated Flow *ULRated Flow psi 18 ServiceFlow Rated Flow *ULRated Flow Z 18 Z 16 N 16 N ao 14 y' ao 14 H • ; z 12 ca 12 '~ • H 6 6 0 50 100 150 200 250 300 350 gpm 0 300 600 900 1200 1500 gpm 0 190 380 570 760 950 1140 1330 Ipm 0 1140 2280 3420 4560 5700 Ipm 15 fps 7.5 12 fps psi 3" (80mm) 8" (20Omm) ServiceFlow Rated Flow *ULRated Flow 16 psi ServiceFlow Rated Flow *ULRated FlowZ 18 14N 16 �,',"" N - 512 Z ao 14 f H o 10 H E 0 12 w V • N.,. � cc is 10 R'•. - LL :L. 8 • w. LL 8 � y,... 6 6 0 100 200 300 400 500 gpm 0 500 1000 1500 2000 2500 gpm 0 380 760 1140 1520 1900 Ipm 0 1900 3800 5700 7600 9500 Ipm 7.5 15 fps 7.5 10 fps 4" (100mm) 10" (25Omm) psi ServiceFlow Rated Flow *ULRated Flow 26 N 16 ServiceFlow Rated Flow ULRated Flow y 22 t H y 14 r r N 18 ,' _.• o 12 H 0 0 o 0 10 a - 14 cc ...,,,'1'°":;::"'"..... y..> a- iP�wpr...... .. 6 6 4 0 100 200 300 400 500 600 700 800 gpm 0 500 1000 1500 2000 2500 3000 3500 gpm 0 380 760 1140 1520 1900 2280 2660 3040 Ipm 0 1900 3800 5700 7600 9500 11400 13300 Ipm 7.5 13 fps 7.5 10 fps NOTICE Inquire with governing authorities for local installation requirements A WATTS Brand USA:Backflow T:(978)689-6066•F:(978)975-8350•AmesFireWater.com USA:Control Valves T:(713)943-0688•F:(713)944-9445•AmesFireWater.com Canada: T:(905)332-4090•F:(905)332-7068•AmesFireWater.ca Latin America: T:(52)81-1001-8600 •AmesFireWater.com ES-A-C400/C400N/C400Z 1730 ©2017 Ames Fire&Waterworks BER MAD WatErworks 0 . . Dimensions &WEi•ht- 700 SEf iES 4 - 700 English Flanged Y Pattern ink/2" 2" 2'/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" L 8.1 8.3 8.7 9.8 12.6 16.3 19.7 23.8 28.5 28.9 39 39.4 43.3 5 W 6.1 6.5 7 7.9 8.8 12.6 15.4 18.9 21.7 21.7 29.1 29.1 29.1 `4: o H `' c h 3.1 3.3 3.7 3.9 4.5 5.6 6.8 8 9.5 10.6 11.8 12.6 14.1 z H 9.4 9.6 10.1 12 14.4 19.4 23 28.5 33.1 34.1 43.6 44.4 45.9 ht o o Q Weight(Ib) 20 23 29 49 82 165 276 478 816 840 1,865 2,083 2,121 + I. L .I o L 8.1 8.3 8.7 10.4 13.2 17 20.6 25.1 30 30.2 40.3 40.6 44.7 o W 6.1 6.5 7.3 8.1 9.8 12.6 15.4 18.9 21.7 22.4 29.1 29.1 29.5 r .• I. ., h 3.1 3.3 3.7 4.1 5 6.3 7.5 8.8 10.3 11.6 12.8 14.1 15.3 w '•,J Q H 9.4 9.6 10.1 12.4 14.9 20 23.7 29.2 33.8 35.2 44.6 45.9 47.1 Weight(Ib) 22 27 33 55 95 187 322 540 904 957 1,984 2,132 2,174 Globe Pattern inch 2" 36" L 57 65 70 73 73 o W 49 49 49 49 49 H C h 18.5 19 20.5 21.8 23.6 ----10 o -- Q H 77 78 79.3 80.6 82.5 h Weight(Ib) 7,150 8,140 8,580 9,020 9,350 L •I L 59 65 70 73 73 IC ' W 49 49 49 49 49 h 18.5 19 20.5 21.8 23.6 w .•. Q H 77 78 79.3 80.6 82.5 Weight(Ib) 7,700 8,140 8,580 9,020 9,370 Angle Pattern 11/2" 2" 21/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" L 4.9 4.9 5.9 6 7.5 8.9 10.4 12.6 15.6 15.7 17.7 17.7 ' o kr- . 0 W 6.1 6.1 7 7.9 8.7 12.6 15.4 18.9 21.7 21.7 29.1 29.1 H r R 3.1 3.3 3.7 3.9 4.5 5.6 6.8 8 9.8 10.4 11.8 12.6 h 3.3 3.3 4.3 4 5 6 8 8.6 10.7 11 14.5 14.5 J h Z Q H 8.9 8.9 9.9 11.1 13.5 17.4 21.5 24.9 30.6 30.7 4.2.6 42.6 ..R►►, L - Weight(Ib) 21 22 27 47 77 157 260 452 772 816 1,764 1,808 L 4.9 4.9 5.9 6.3 7.9 9.2 10.9 13.2 16.3 16.5 18.4 18.4 0o W 6.5 6.5 7.3 8.1 9.8 12.6 15.4 18.9 21.7 21.7 29.1 29.1 H� R 3.1 3.3 3.7 4.1 5 6.3 7.5 8.8 10.3 11.5 12.8 14 w o o"°O - z h 3.3 3.3 4.3 4.3 5.3 6.5 8.5 9.3 11.6 11.8 15.2 15.2 ' Ell• • Q H 8.9 8.9 9.9 11.3 13.8 17.9 22.0 25.6 31.3 31.5 43.3 43.3 Weight(Ib) 24 25 30 51 90 17.9 304 514 860 937 1,885 1,918 Threaded Angle Pattern inch 2" 21/2" 3" Y Pattern inch 11/2" 2" 2'/2" 3" 4.8 5.5 6.3L 6.1 6.1 8.3 9.8 _ :_ .- o W 4.8 4.8 6.4 `. W 4.8 4.8 4.8 6.4 CLH H ZCC R 1.6 1.9 2.2 Z ° o Ih h 3.3 4 4.5 �h= '° - °I h 1.6 1.6 1.9 2.2 + m H 8.9 9.5 11.6i mm H 7.9 8 8.2 10.4 w Weight(Ib) 12 15 33 Weight(Ib) 12 12 18 37 R Control Chamber Displacement Volume(gallon) Sizes 11/2"-21/2" 3" 4" 6" 8" 10" 12"-14" 16"-20" 24"-36" 700 Series 0.04 0.08 0.12 0.57 1.19 2.25 3.28 7.88 25.9 800 Series 0.01 0.03 0.08 0.29 0.61 1.06 2.12 4.95 - ...swinfo@bermad.com • www.bermad.com The information herein is subject to change without notice. B ERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by BERMAD. PT7XE01-09 09 SE111110 BER MAD WatErworks 0 700 SEf iEs I? 700 English o� o Y Pattern,Flat Disc 15 / (r)10 _ _ _ _km : i1 16" _18" /28" a ,� rrrH/ti%/ 20" 30„ u> / / 32" fir , , 1 24» u) 5 J DN600-900 valves s— = are Globe pattern to / U) 2 / a 1- I / / 10 50 100 500 1,000 5,000 10,000 50,000 100,000 Flow Rate- gpm(Water) o o Y Pattern,ThrottlingPlug (V-Port) 15 10 i®,, _. ALA 10' 03/ u, a C) 5 Co 0 J ia) I 7 rn rn LT i a 1 1 I I i I I I 1--- 10 10 50 100 500 1,000 5,000 10,000 50,000 100,000 Flow Rate- gpm(Water) info@bermad.com • www.bermad.com The information herein is subject to change without notice. B ERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by B ERMAD. UMW BER MAD WatErworks 0 Flow Charts 700 SEriEs 700 English Angle Pattern,Flat Disc ) cam_ 115 10- - / / • 8 10" 16 /18" Q ffitwr/airrl�4110"NI 14" Cl) 5 / o � J / a)) / 7 / co i) a 1- / A,,r(i 1 1 10 50 100 500 1,000 5,000 10,000 50,000 100,000 Flow Rate- gpm(Water) Angle Pattern,ThrottlingPlug (V-Port) 15 A 10 ,��..`-rf�A 6" 43I10 y 14" . ( r rf 1 r sn 5 U) O J O i 3 N co O i a 1 10 50 100 500 1,000 5,000 10,000 50,000 100,000 Flow Rate-gpm(Water) sAd info@bermad.com • www.bermad.com loft The information herein is subject to change without notice. B ERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by B ERMAD. PT7XE01-12 09 BER MAD WatErworks . 11111 700 SEriES- U 700 English inch 1.5" 2" 2.5" 3" 4" 6"41. 8" 10" 12" 14" 16" 18" 20" Y-Pattern Cv 49 58 64 133 230 530 940 1,440 2,140 2,300 3,820 3,960 4,100 Flat Disc ta, K 2.3 3.9 I 9.2 4.9 3.9 3.7 3.8 3.9 3.7 5.9 3.7 5.5 7.8 II Leq-feet 14.2 33.8 109.5 70.8 75.6 123.0 176.9 229.5 280.8 524.5 369.6 671.9 1,062.3 Y-Pattern Cv 41 49 54 113 200 450 800 1,230 1,820 1,950 3,250 3,370 3,490 V-Port 411 K3.1 5.4 12.8 6.7 5.4 5.2 5.2 5.4 5.1 8.2 5.1 7.6 10.8 Leq-feet 19.7 46.8 151.6 97.9 104.6 170.2 244.8 317.6 388.6 725.9 511.6 930.0 1,470.3 Angle Cv 53 64 70 146 250 580 1,040 1,590 2,350 2,530 4,210 4,360 NA Pattern K 1.9 3.2 7.6 4.0 3.2 3.1 3.1 3.2 3.1 4.9 3.0 4.5 NA Flat Disc Leq-feet 11.7 28.0 90.5 58.5 62.5 101.6 146.2 189.7 232.0 433.4 305.5 555.3 NA Angle Cv 45 54 59 124 220 500 880 1,350 2,000 2,150 3,580 3,710 NA Pattern K"" 2.6 4.5 10.6 5.6 4.5 4.3 4.3 4.5 4.2 6.8 4.2 6.2 NA V-Port Leq-feet 16.3 38.7 125.3 80.9 86.5 140.7 202.4 262.5 321.2 599.9 422.8 768.6 NA inch 24" 28" 30" 32" 36" G-Pattern Cv 8,490 8,670 8,670 8,670 8,670 Flat Disc K 3.8 6.7 8.8 11.4 17.1 Leq-feet 616.6 1,280.0 1,807.3 2,495.6 4,136.5 Differential Pressure Calculation I Valveflow coefficient,Kv or Cv Kv(Cv) =Q,I�P Flow resistance or Head loss coefficient, K =0 H Vg Where: V Where: Kv=Valve flow coefficient(flowin m3/h at 1bar AP) K = Flowresistance or Head loss coefficient(dimensionless) Cv=Valve flow coefficient(flow in gpm at 1psi AP) AH= Head loss (m ; feet) (Cv= 1.155 Kv) V = Nominal size flow velocity(m/sec; feet/sec.) Q = Flow rate(m3/h ; gpm) g =Acceleration of gravity(9.81 m/sec2; 32.18 feet/sec2) -P = Differential pressure(bar; psi) Practical formula: Gf = Liquid specific gravity(Water= 1.0) 2 Practicalformulasforwater: AH = K V 2 2g Q = Kv-/AP AP =\ -Q KV- Equivalent Pipe Length- Leq In orderto simplify system head loss calculation, add the Leq value to the pipe length of the relevant size Note: The Leq values given are forgeneral considerationonly. Actual Leq may varysomewhat with each of the valve sizes. info@bermad.com • www.bermad.com The information herein is subject to change without notice. B ERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by B ERMAD. PT7XE01-16 09 UMW BER MAD WatErworks ° Cav 1111111111.1 700 SEi'iE5 US English CavitationGuidE 120 110 100 a 90 I- 80 I I N 70 I E 60 F�a� 5G /// cri 50 vQo�Q�v�I 40 0 30 ' I' Cavitation 20 I I Damage Zone 10 II' 0 0 30 60 90 120 150 180 210 240 270 300 330 360 Upstreampressure - psi Cav itatio n The cavitationphenomenon has a significant affect on Use these guide and your applications upstreamand control valve and system performance. downstreampressures to determine whether their Cavitationmay damage the valve and piping by the affects intersectionlies in or out of the cavitationdamage zone. of erosion and vibration.Cavitationalso generates noise and Considerations to avoid cavitationdamage: may limit and ultimately choke the flow. A) Reduce system pressure in stages designing each As the pressure differential acrossthe valve increases,the pressure stage to be abovecavitationconditions. static pressure of the flow passing through the throttling area B) Consider using other valve selection criteria of the valve(Vena Contracta)drops sharply. a.Valve body and plug type When the fluid's static pressure reaches liquid vapor b.Valve size pressure,vaporcavities(bubbles)form and grow until they c.Valve material violently implode by the recovered pressure downstreamto Notes: the valveseat. 1. An alternate cavitationindex formula introduced by The implosion of these cavities generates high-p ressure ISA is: surges,micro jets and intensive heat,which erode valve 61SA=(P1 Pv)/(P1 P2) which equals 0+1 components and downstreampiping. In its final stage, 2. The abovecharts should be considered only as a cavitationflashes and chokes the flow. general guide. The aboveCavitationGuide for B ermad700 Series valves 3. Foroptimum system and controlvalveapplication please are based on the formula commonly used in the valve industry: consult Bermad. 6 = (P2-Pv)/(P1-P2) Where: 0 = Sigma, cavitationindex, dimensionless P1 = Upstreampressure,absolute P2 = Downstream pressure, absolute Pv = Liquid vaporpressure, absolute (Water, 18°C=0.02 bar-a ; 65°F=0.3 psi-a) info@bermad.com • www.bermad.com The information herein is subject to change without notice. B ERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by B ERMAD. PT7XE01-14 09 SE111110 BER MAD WatErworks 0 . . �- .._ - 700 Valve-Ex•loded 111111 700 SEri Lifting eye nut Cover bolt&disc ,/ Coverplug if . ..,* 0-ring Cover Indicator nut • Shaft nut Diaphragm washer Spacerdisc Shaft - Diaphragm Diaphragm washer Separatingpartition • 1 /f Bearingscrew Lifting eye bolt O-ring Bearingdisc d Bearing Covernut&disc gl 0-rings Stud - J 4 Spring `t 0-ring Seal disc ‘14 Seal disc nut ft Seal Shaft locking screw Seal disc screws Seal disc washer At Seat screw T+: V-Port throttling plug-option Nut &disc Valve body Seat Control hub - Control hub Drain / —0.- For sparepartsordering,please use B ERMAD"Sp are Parts Ordering Guide." info@bermad.com • www.bermad.comsaw The information herein is subject to change without notice. B ERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by B ERMAD. PT7XEel-04 09 1111111110 _ BER MAD WatErworks MINICIMMEMPI 700 SEriEs Standard OperationPressure- Materials Data End Connections Standards/Pressure Ratings/Materials/Max.Operating Pressure End Ductile Iron to Carbon Steel to Stainless Steel 316 Nickel Aluminum B ermad Pressure B ronzeto Connections ASTM A-536 ASTM A-216-WCB to ASTM A-743 CF8M Code Class ASTM B-148 C 95800 Standard or EN 1563 or EN 10083-1 or EN 10088-1 or BS-EN1400 AB-2 10 or E1 ISO PN10 + + + + 16 or E6 I S 0 PN 16 + + + 16 bar 25 or E5 I S 0 PN 25 25 bar 25 bar 25 bar 25 bar 40 I S 0 PN 40* — 40 bar 40 bar — A5 ANSI # 150 250 psi 285 psi 285 psi 250 psi A3 ANSI #300 400 psi 400 psi 400 psi 400 psi A4 ANSI #400* — 600 psi 600 psi — B D BS 10 Table D + + + + B H BS 10 Table H 400 psi 400 psi 400 psi 400 psi J1 JIS 10K + + + + J6 J I S 16 K 27 bar 27 bar 27 bar 27 bar J2 J I S 20 K 28 bar 28 bar 28 bar 28 bar J3 J I S 30 K* — 40 bar 40 bar — B1 ABNT 10 + + + + B6 ABNT 16 + + + 16 bar B2 ABNT 25 25 bar 25 bar 25 bar 25 bar Threads BP BSP(Rp ISO 7/1) PH B S P(Rp ISO 7/1) 25 bar 25 bar 25 bar 25 bar NP NPT NH NPT 400 psi 400 psi 400 psi 400 psi External flange diameter might varyfromthe standard. * Can be used in 800 series only. + Available, Not required by the standard pressure class — Not available info@bermad.com • www.bermad.com shi The information herein is subject to change without notice. B ERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by B ERMAD. PT7xE01-03 09 UMW BER MAD WatErworks 700 SEf iEs ValvePlugs Characteristics Kv; Cv to ValveOp ening Chart 100 90 80 70 060Tu J- Qo� 50 pyo a> *N2 I $ 40 30 oipillIllIllPPIIII"- 20 I 10 0 0 10 20 30 40 50 60 70 80 90 100 Kv; Cv % Typical Pressure Reducing PErformancEChart Actual Hydraulic Laboratory Results 15 14 - f - 700 13 - 12 — 600 11 - \ 10 500 g - pstreamPressureg gI 400 M L E co a 6 - Flow Rate - 300 0 a 5 - _ a 4 _ -4— -- - 200 3 Downstream Pressure 2 100 1 - 0 I I I I I I i I I I I 0 0 100 200 300 400 500 600 700 800 900 1,000 1,100 1,200 Time - sec ..swinfo@bermad.com • www.bermad.com The information herein is subject to change without notice. B ERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by B ERMAD. PT7XE01-17 09 UMW _