Loading...
HomeMy WebLinkAboutF18-0074_Approved Documents_1543262475.pdf 75 South Frontage Road Fire -Construction Permit West, TOWN OF VAIL F18-0074 Vail, CO 81657 Issued: 11/26/2018 TOWN of VAILOFOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 715 W LIONSHEAD CIR(210107217001)(210107217001) Unit#: P a r c e IN u tuber: 210107217001 LegalDescription: Subdivision:WEST DAYSUBDIVISION Lot: 1 R908760 MAP 03-10-05 R910219 BSD 03-24-05 R920513 EAS 06-24-05 R200625646 EAS 09-20-06 R200715212 EAS 06-11-07 R200719892EAS 07-27-07 Contacts ContactType: Applicant Full Name: PeterMazen Address: 274 CenterDrive Glenwood Springs,CO 81601 Phone: 3037920022 ContactType: PropertyOwner FuIlName: DIAMONDROCKVAIL OWNERLLC DIAMONDROCKHOSPITALITYCO Address: Phone: None Contractor Contractor Type: Fire Protection Company: WesternStates Fire ProtectionCo. State License#: Phone: 303-549-8975 Projectlnformation ProjeciName: Vail MarriottRenovation2018 ProjeciDescription: Relocate 87 sprinklers to adapt to new wall and ceiling location. Fees Paid Account#:001-0000.31111.00-Fire SuppressionPermitFee Fee Amount: $2,588.25 Account#:001-0000.31123.00 Fire SuppressionReviewFee Fee Amount: $432.00 TotalPaid: $3,020.25 Conditions Issued By: Town ofVailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicantagrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law. Failure to do so will void this Permitand the applicantshall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # F 18-0074 Date Printed: 11/20/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0074 Status: Created Permit Number: Date Started: 11/19/2018 Permit Type: Fire-Construction Permit Subc ases Fire Suppression Lot Number: Property: 715 W LI ONSHEAD CI R(210107217001)(210107217001) Contacts Contact Type: Applicant Company Name: Western States Fire Protection Full Name: Peter Mazen Address: 274 Center Drive Glenwood Springs,CO 81601 Email: peter.mazen@wsfp.us Contact Type: Property Owner Full Name: DIAMONDROCKVAI L OWNER LLC DIAMOND Address: Permit Fees Fee Information Account Amount Fire Suppression Permit Fee 001-0000.31111.00 $2,588.25 Fire Suppression Review Fee 001-0000.31123.00 $432.00 Payment Information Date Paid Payment Type Amount Fire Suppression Permit Fee 11/20/2018 Check $2,588.25 Paid By:Carolyn Godfrey-Notes:ck#124577 Western States Fire Protection Fire Suppression Review Fee 11/20/2018 Check $432.00 Paid By:Carolyn Godfrey-Notes:ck#124577 Western States Fire Protection FEE TOTAL $3,020.25 AMOUNT PAID $3,020.25 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 11/20/2018-2:24:49 PM-Generated by:cgodfrey 1/1 6 Western States Fire Protection Co. Protectift9 .Elim aid promo FIRE PROTECTION SYSTEM Hydraulic Calculation and Material Submittal Vail Marriott Level2 East Revisions 715 W Lionshead Circle Vail, CO 81657 Thomas M.Coakley,CET Western States Fire Protection Co. NICET Level III Registration#107852 Sprinkler Systemys�Layout Signa ZIO Prepared by: PeterMazen Project Manager Western StatesFire Protection Co. 7026 S. Tucson Way Centennial,CO 80112 Phone(303)-792-0022 Fax(303)792-9049 WSFP#CS3036 November 13, 2018 Hydraulic Overview \ Job Number:CS3036 Report Description:Light Hazard-CALC#1 Job Number Circuit Description CS3036 Peter Mazen Job Name: Phone FAX VAIL MARRIOTT LVL 2 EAST 530-518-4299 Address 1 Stale Certification/License Number 715 W LIONSHEAD CIR Address 2 AHJ VAIL,CO 81657 Address 3 Part Description Density Area of Application 0.10gpm/ft2 1500ft2(Actual 971W) Most Demanding SprinklerData Hose Streams 5.6 K-Factor 19.60 at 12.250 100.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 196ft2 13 System Pressure Demand system Flow Demand 103.671 328.13 Total Demand Pressure Result 428.13 @ 103.671 +37.989(26.8%) Supplies Check Point Gauges art Numb( Name Flow(gpm) Hose Flow(gpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(gpm) 1 Water Supply 1210.00 100.00 150.000 93.000 CS3036-Vail Marriott Phase 2 Submittal Drawings. Water Supply at Node 1 (1210.00, 0.00,150.000, 93.000) 200 180 • — B.a ISI 1 160 f I Static Pressure 150.000 140 _ 120 \• 328.13 103.671 100LuuwtnhIuhiwIHuhIIIHHIIIIrIIIIIIIIIIIpI I 210.00 @ 93.000 28.13 with hose streams o_ 80 60 stem demand rve 40 20 0 1111111 111111111 0075Q10001250 1500 1750 2000 2250 2500 Water flow,gpm ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:08PM Page 1 Hydraulic Graph Job Number:CS3036 Report Description:Light Hazard-CALC#1 Water Supply at Node 1 200 180 160 Static Pressure 150.000 140 - 120 — 328.13 @ 103.671 1 2 100 I 428.13 with hose streams 1210.00 @ 93.000 a 80 60 System demand curve 40 20 0 —miniiiiiiiiiiiiii iiiiiiiii 111111111 111111111 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i i 1 1 1 1 1 1 1 250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Hydraulic Graph Water Supply at Node 1 S tatiorressure 150.000 Residual:Pressure 93.000 @ 1210.00 Available Pressure at Time of Test 141.661 @ 428.13 s vaenoemana 103.671 @ 328.13 S ystenDemand(Including Hose Allowance at Source) 103.671 @ 428.13 �4 ©M.E.P.CAD,Inc. i AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:12PM Page 2 i Summary Of Outflowing Devices I Job Number:CS 3036 5• - Report Description:LightHazard-CALC#1 Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) 4, Sprink ler 517 19.60 19.60 5.6 12.250 Sprinkler 518 19.89 19.60 5.6 12.620 Sprinkler 519 22.28 19.60 5.6 15.831 Sprinkler 529 20.23 19.60 5.6 13.057 Sprinkler 530 21.13 19.60 5.6 14.242 Sprinkler 531 23.44 19.60 5.6 17.513 Sprinkler 539 23.01 19.60 5.6 16.879 Sprinkler 540 23.58 19.60 5.6 17.730 Sprinkler 541 26.46 19.60 5.6 22.328 Sprinkler 556 40.49 19.60 5.6 52.275 Sprinkler 557 29.64 19.60 5.6 28.013 Sprinkler 558 33.71 19.60 5.6 36.230 Sprinkler 640 24.66 19.60 5.6 19.396 ♦ Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:21PM Page 3 iii Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 DR 1.0490 19.60 7.28 120 0.125357 15'-4 Pf 2.677 517 9'-5 19.60 5.6 12.250 Sprinkler, 6'-0 Pe -0.903 119 11'-6 14.024 3E(2'-0) 21'-4 Pv BL 1.0490 39.83 14.79 120 0.465550 8'-0 Pf 3.724 119 11'-6 20.23 14.024 Flow(q)from Route 3 Pe 158 11'-6 17.748 8'-0 Pv BL 1.0490 62.84 23.33 120 1.082035 3'-0 Pf 3.240 158 11'-6 23.01 17.748 Flow(q)from Route 6 Pe 209 11.-6 20.988 3'-0 Pv BL 1.0490 87.50 32.48 120 1.996349 5'-7 Pf 11.180 209 11'-6 24.66 20.988 Flow(q)from Route 9 Pe 251 11'-6 32.168 5'-7 Pv BL 1.4420 117.14 23.01 120 0.727150 32'-2 Pf 28.774 251 11'-6 29.64 32.168 Flow(q)from Route 11 7'-5 Pe 379 11'-6 60.941 PO(T-5) 39'-7 Pv CM 3.2600 287.64 11.06 120 0.072135 6'-10 Pf 0.492 379 11'-6 170.49 60.941 Flow(q)from Route 2 Pe 378 11'-6 61.433 6'-10 Pv CM 3.2600 328.13 12.61 120 0.092036 47'-9 Pf 8.103 378 11'-6 40.49 61.433 Flow(q)from Route 13 40'-4 Pe 354 11'-6 69.536 2T(20'-2) 88'-1 Pv CM 4.2600 328.13 7.39 120 0.025009 130'-4 Pf 19.488 354 11'-6 69.536 226'-6 Pe 10.694 12 -13'-2 99.718 2f(-0.000),BV(15'-10),16E(13'- 356'-10 Pv 2),BFP(-9.348),PRV(-1.216) UG 4.2200 328.13 7.53 140 0.019688 57'-3 Pf 1.786 12 -15-2 99.718 35-5 Pe 11 -13'-2 101.504 T(33'-5) 90'-9 Pv UG 6.2800 328.13 3.40 140 0.002841 719'-0 Pf 2.168 11 -13'-2 101.504 44'-2 Pe 1 -13'-2 103.671 4EE(11'-0),S 763'-1 Pv 100.00 Hose AllowanceAt Source 1 428.13 Route 2 DR 1.0490 19.89 7.39 120 0.128860 17'-9 Pf 3.700 518 9'-5 19.89 5.6 12.620 Sprinkler, 11'-0 Pe -0.903 125 11'-6 15.417 3E(2'-0),T(5'-0) 28'-9 Pv BL 1.0490 41.03 15.23 120 0.491665 10'-0 Pf 4.913 125 11'-6 21.13 15.417 Flow(q)fromRoute4 Pe 197 11.-6 20.330 10'-0 Pv BL 1.0490 64.61 23.98 120 1.138931 12'-11 Pf 19.301 197 11'-6 23.58 20.330 Flow(q)from Route 8 4'-0 Pe 255 11'-6 39.632 2E(2'-0) 16'-11 Pv BL 1.4420 98.31 19.31 120 0.525817 32'-2 Pf 20.807 255 11'-6 33.71 39.632 Flow(q)from Route 12 7'-5 Pe 380 11'-6 60.438 P0(7-5) 39'-7 Pv CM 3.2600 170.49 6.55 120 0.027412 18'-4 Pf 0.503 380 11'-6 72.18 60.438 Flow(q)from Route 5 Pe 379 11'-6 60.941 18'-4 Pv Route 3 DR 1.0490 20.23 7.51 120 0.132974 5-1 Pf 1.871 529 9'-5 20.23 5.6 13.057 Sprinkler, 9'-0 Pe -0.903 119 11'-6 14.024 2E(2'-0),T(5'-0) 14'-1 Pv Route 4 DR 1.0490 21.13 7.85 120 0.144104 5'-5 Pf 2.078 530 9'-5 21.13 5.6 14.242 Sprinkler, 9'-0 Pe -0.903 125 11'-6 15.417 2E(2'-0),C(5'-0) 14'-5 Pv - Route 5 _ DR 1.0490 22.28 8.27 120 0.158916 18'-9 Pf 4.722 519 9'-5 22.28 5.6 15.831 Sprinkler, 11'-0 Pe -0.903 127 11'-6 19.650 3E(2'-0),T(5'-0) 29'-9 Pv BL 1.0490 45.72 16.97 120 0.600632 8'-0 Pf 4.805 127 11'-6 23.44 19.650 Flow(q)from Route 7 Pe 164 11'-6 24.455 8'-0 Pv ©M.E.P.CAD,Inc. NUAutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:25PM Page 4 b�ii Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length BL 1.0490 72.18 26.79 120 1.398058 13'-4 Pf 24.196 164 11'-6 26.46 24.455 Flow(q)from Route 10 4'-0 Pe 259 11'-6 48.651 2E(2'-0) 17'-4 Pv BL 1.4420 72.18 14.18 120 0.296853 32'-2 Pf 11.747 259 11'-6 48.651 7'-5 Pe 381 11'-6 60.397 PO(7-5) 39'-7 Pv CM 3.2600 72.18 2.77 120 0.005589 7'-4 Pf 0.041 381 11.-6 60.397 Pe 380 11'-6 60.438 7'-4 Pv OF Route 6 DR 1.0490 23.01 8.54 120 0.168626 3'-6 Pf 1.772 539 9'-5 23.01 5.6 16.879 Sprinkler, 7'-0 Pe -0.903 158 11'-6 17.748 E(2'-0),T(5'-0) 10'-6 Pv Route 7 DR 1.0490 23.44 8.70 120 0.174472 8'-5 Pf 3.040 531 9'-5 23.44 5.6 17.513 Sprinkler, 9'-0 Pe -0.903 127 11'-6 19.650 2E(2'-0),T(5'-0) 17'-5 Pv - Route 8 DR 1.0490 23.58 8.75 120 0.176469 5'-10 Pf 3.504 540 9'-5 23.58 5.6 17.730 Sprinkler, 14'-0 Pe -0.903 197 11'-6 20.330 2E(2'-0),2T(5'-0) 19'-10 Pv OF Route 9 DR 1.0490 24.66 9.16 120 0.191757 6'-0 Pf 2.495 640 9'-5 24.66 5.6 19.396 Sprinkler, 7'-0 Pe -0.903 209 11'-6 20.988 E(2'-0),T(5'-0) 13'-0 Pv Route 10 DR 1.0490 26.46 9.82 120 0.218433 6'-10 Pf 3.029 541 9'-5 26.46 5.6 22.328 Sprinkler, 7'-0 Pe -0.903 164 11'-6 24.455 E(2'-0),T(5'-0) 13'-10 Pv - Route 11 DR 1.0490 29.64 11.00 120 0.269417 9'-3 Pf 4.372 557 11'-0 29.64 5.6 28.013 Sprinkler, 7'-0 Pe -0.217 251 11'-6 32.168 E(2'-0),T(5'-0) 16-3 Pv Route 12 DR 1.0490 33.71 12.51 120 0.341793 3'-7 Pf 3.618 558 11'-0 33.71 5.6 36.230 Sprinkler, 7'-0 Pe -0.217 255 11'-6 39.632 E(2'-0),T(5'-0) 10'-7 Pv - Route 13 DR 1.0490 40.49 15.03 120 0.479788 4'-2 Pf 5.343 556 11'-0 40.49 5.6 52.275 Sprinkler, 7'-0 Pe -0.217 247 11'-6 57.402 E(2'-0),T(5'-0) 11'-2 Pv BL 1.4420 40.49 7.95 120 0.101874 32'-2 Pf 4.031 247 11.-6 57.402 7'-5 Pe 378 11'-6 61.433 P0(7.-5) 39'-7 Pv Equivalent Pipe Lengths of Valvesand Fittings(C=120 only) wiMI C Value Multiplier -11 Actual Inside Diameter 4.87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD,Inc. ,111 AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:25PM Page 5 Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary _ Upstream Total Length Pipe Type Legend Units Legend EMMEp 111 Fittings Legend i AO Arm-Over Diameter Inch ALV AlarmValve BL Branch Line Elevation Foot AngV Angle Valve CM Cross MainFlow gpm b Bushing DN Drain BaIV Ball Valve DR Drop Discharge gpm BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous FrictionLoss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple DeIV Deluge Valve Pt Totalpressure at a point in a pipe SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90°Elbow UG Underground Pf Pressure loss due to friction between points EE 45°Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 22W Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. ,111 AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:25PM Page 6 NilHydraulic Overview \ Job Number:CS3036 Report Description:Light Hazard-CALC#2 Job Number Circuit Description CS3036 Peter Mazen Job Name: Phone FAX VAIL MARRIOTT LVL 2 EAST 530-518-4299 Address 1 State Certification/License Number 715 W LIONSHEAD CIR Address 2 AHJ VAIL,CO 81657 Address 3 Part Description Density Area of Application 0.10gpm/ft2 1500ft2(Actual 1084ft') Most Demanding SprinklerData Hose Streams 5.6 K-Factor 22.50 at 16.143 100.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 225ft2 8 System Pressure Demand system Flow Demand 82.578 207.18 Total Demand Pressure Result 307.18 @ 82.578 +62.910(43.2%) Supplies Check Point Gauges art Numb( Name Flow(gpm) Hose Flow(gpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(gpm) 1 Water Supply 1210.00 100.00 150.000 93.000 CS3036-Vail Marriott Phase 2 Submittal Drawings. Water Supply at Node 1 (1210.00, 0.00,150.000, 93.000) 200 180 Ir 160 Static Pressure 150.000 Ell I` 140 •_ 120 N 100 1210.00 @ 93.000 N 80 a •= 307.18 with hose streams 60 System demand curve 40 20 0 allllllllal�lllll lllllllll IIIIIIIII IIIIIIIII 111111111 111111111 1111111 111111111 5h.?)007501000 1250 1500 1750 2000 2250 2500 Water flow,gpm ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:53PM Page 1 Hydraulic Graph Job Number:CS3036 Report Description:Light Hazard-CALC#2 Water Supply at Node 1 200 180 160 Static Pressure 150.000 140 120 N Q 100 1210.00 @ 93.000 a 207.18 @ 82.578 1 80 307.18 with hose streams 60 System demand curve 40 20 0 —.L111111111 111111111 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i 1 1 1 1 1 1 1 1 1 I 1 1 1 i i 1 1 250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Hydraulic Graph Water Supply at Node 1 S tatiorressure 150.000 Residual:Pressure 93.000 @ 1210.00 Available Pressure at Time of Test 145.488 @ 307.18 s vaenoemana 82.578 @ 207.18 S ystenDemand(Including Hose Allowance at Source) 82.578 @ 307.18 �4 ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:27:57PM Page 2 i Summary Of Outflowing Devices I Job Number:CS 3036 5• - Report Description:Light Hazard-CALC#2 Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) Sprinkler 583 28.05 22.50 5.6 25.085 Sprinkler 584 30.29 22.50 5.6 29.265 Sprinkler 588 26.96 22.50 5.6 23.178 Sprinkler 589 28.29 22.50 5.6 25.520 Sprinkler 593 24.45 22.50 5.6 19.063 Sprinkler 594 23.65 22.50 5.6 17.837 Sprinkler 598 22.98 22.50 5.6 16.844 * Sprinkler 599 22.50 22.50 5.6 16.143 ♦ Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:28:06PM Page 3 iii Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 DR 1.0490 22.50 8.35 120 0.161813 14'-6 Pf 2.670 599 11'-0 22.50 5.6 16.143 Sprinkler, 2'-0 Pe -0.217 478 11'-6 18.596 E(2'-0) 16'-6 Pv BL 1.0490 46.15 17.13 120 0.611240 13'-0 Pf 7.934 478 11'-6 23.65 18.596 Flow(q)from Route 3 Pe 459 11'-6 26.531 13'-0 Pv BL 1.4420 46.15 9.07 120 0.129786 1'-0 Pf 0.132 459 11'-6 26.531 Pe 449 11'-6 26.663 1'-0 Pv BL 1.4420 74.44 14.62 120 0.314299 12'-6 Pf 3.929 449 11'-6 28.29 26.663 Flow(q)from Route 7 Pe 433 11'-6 30.592 12'-6 Pv BL 1.4420 104.74 20.58 120 0.591107 34'-7 Pf 24.834 433 11'-6 30.29 30.592 Flow(q)from Route 8 7'-5 Pe 368 11'-6 55.426 P0(7'-5) 42'-0 Pv CM 3.2600 207.18 7.96 120 0.039311 28'-10 Pf 2.720 368 11'-6 102.44 55.426 Flow(q)from Route 2 40'-4 Pe 354 11'-6 58.146 2T(20'-2) 69'-2 Pv CM 4.2600 207.18 4.66 120 0.010682 130'-4 Pf 12.049 354 11'-6 58.146 226'-6 Pe 10.694 12 -13'-2 80.889 2f(-0.000),BV(15'-10),16E(13'- 356'-10 Pv 2),BFP(-8.061),PRV(-0.177) UG 4.2200 207.18 4.75 140 0.008409 57'-3 Pf 0.763 12 -13'-2 80.889 33'-5 Pe 11 -13'-2 81.652 T(33'-5) 90'-9 Pv UG 6.2800 207.18 2.15 140 0.001213 719'-0 Pf 0.926 11 -13'-2 81.652 44'-2 Pe 1 -13'-2 82.578 4EE(11'-0),S 763'-1 Pv 100.00 Hose AllowanceAt Source 1 307.18 Route 2 DR 1.0490 22.98 8.53 120 0.168300 20'-10 Pf 5.021 598 11'-0 22.98 5.6 16.844 Sprinkler, 9'-0 Pe -0.217 468 11'-6 21.648 2E(2'-0),T(5'-0) 29'-10 Pv BL 1.0490 47.43 17.61 120 0.643036 6'-0 Pf 3.854 468 11'-6 24.45 21.648 Flow(q)fromRoute4 Pe 464 11'-6 25.502 6'-0 Pv BL 1.4420 47.43 9.32 120 0.136537 6'-0 Pf 0.818 464 11'-6 25.502 Pe 456 11'-6 26.320 6'-0 Pv BL 1.4420 74.39 14.61 120 0.313931 10'-0 Pf 3.137 456 11'-6 26.96 26.320 Flow(q)from Route 5 Pe 439 11'-6 29.457 10'-0 Pv BL 1.4420 102.44 20.12 120 0.567375 38'-1 Pf 25.838 439 11'-6 28.05 29.457 Flow(q)from Route 6 7'-5 Pe 366 11'-6 55.295 P0(7'-5) 45'-6 Pv CM 3.2600 102.44 3.94 120 0.010682 12'-3 Pf 0.131 366 11'-6 55.295 Pe 368 11'-6 55.426 12'-3 Pv Route 3 DR 1.0490 23.65 8.78 120 0.177459 0'-6 Pf 0.976 594 11'-0 23.65 5.6 17.837 Sprinkler, 5'-0 Pe -0.217 478 11'-6 18.596 T(5'-0) 5'-6 Pv Route 4 DR 1.0490 24.45 9.08 120 0.188714 5'-10 Pf 2.801 593 11'-0 24.45 5.6 19.063 Sprinkler, 9'-0 Pe -0.217 468 11'-6 21.648 2E(2'-0),C(5'-0) 14'-10 Pv - Route 5 DR 1.0490 26.96 10.01 120 0.226106 5'-10 Pf 3.359 588 11'-0 26.96 5.6 23.178 Sprinkler, 9'-0 Pe -0.217 456 11'-6 26.320 2E(2'-0),C(5'-0) 14'-10 Pv OF Route 6 DR 1.0490 28.05 10.41 120 0.243265 9'-10 Pf 4.589 583 11'-0 28.05 5.6 25.085 Sprinkler, 9'-0 Pe -0.217 439 11'-6 29.457 2E(2'-0),C(5'-0) 18'-10 Pv Route 7 ©M.E.P.CAD,Inc. WO AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:28:10PM Page 4 Hydraulic Analysis Job Number:CS3036 Report Description:Light Hazard-CALC#2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length DR 1.0490 28.29 10.50 120 0.247169 0'-6 Pf 1.359 589 11-0 28.29 5.6 25.520 Sprinkler, 5'-0 Pe -0.217 449 11'-6 26.663 T(5'-0) 5'-6 Pv Route 8 DR 1.0490 30.29 11.25 120 0.280545 0'-6 Pf 1.543 584 11'-0 30.29 5.6 29.265 Sprinkler, 5'-0 Pe -0.217 433 11'-6 30.592 T(5'-0) 5'-6 Pv Equivalent Pipe Lengths of Valvesand Fittings(C=120 only) Actual Inside Diameter 4 87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor MultiplyingFactor p 0.713 1.16 1.33 1.51 Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV AlarmValve BL Branch Line Elevation Foot AngV Angle Valve CM Cross MainFlow gpm b Bushing DN Drain BaIV Ball Valve DR Drop Discharge gpm BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Totalpressure at a point in a pipe DeIV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90°Elbow UG Underground Pf Pressure loss due to friction between points EE 45°Elbow Pe Pressure due to elevation difference between indicated Eel 111/4°Elbow points Ee2 221/ Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.2.9.0 11/13/2018 12:28:10PM Page 5 CAST IRON THREADED FITTINGS !6 • Z '11 Ja i - _ •3 _ }.: ''' ':. 't` ir 1Ii1 ip Iv . ,., .*.v. ...„. ..:, - _,. . . .. . .,:.i. -_....-. ,, :.:,„:1: . .-}, _40%.,...._ 441.,.., F - . - . . 'Ilial -W-- .% )00art. F i ] _ _._ • Anvil standard and extra heavy cast iron threaded fittings Cast Iron Threaded Fittings are manufactured in accordance with ASME B16.4.Plugs and Pressure - Temperature Ratings bushings are manufactured in accordance with ASME B16.14. Pressure Temperature Class 125 Class 250 NOTE:Figure 367 Concentric Reducers do not meet the overall length -1°F) (°C) + psi bar psi bar requirement of ASME B16.4. All other dimensions are in compliance. -20°to 150° -28.9 to65.6 175 12.1 400 27.6 200° 93.3 165 11.4 370 25.5 C UL US 250° 121.1 150 10.3 340 23.4 APPROVED 300° 148.9 140 9.7 310 21.4 For Listings/Approval Details and Limitations,visit our website at 350° 176.7 125 8.6 300 20.7 www.anvilintl.com or contact an Anvil Sales Representative. 400° 204.4 - - 250 17.2 Standards and Specifications Dimensions Material Galvanizing* Thread Pressure Rating CAST IRON THREADED FITTINGS Class 125 ASME B16.4 ASTM A-126 (A) ASTM A-153 ASME B1.20.1 ASME B16.4 Class 250 ASME 816.4 ASTM A-126 (A) ASTM A-153 ASME B1.20.1 ASME B16.4 CAST IRON PLUGS AND BUSHINGS 7 ASME B16.14 ASTM A-126 (A) ASTM A-153 ASME B1.20.1 ASME B16.14 "ASTM B 633.Type I,SC 4,may be supplied as alternate zinc coating per applicable ASME B16 product standard. PF-11.16 IPS CARBON STEEL PIPE- FIRE PROTECTION PRODUCTS 10.02 I VICTAULID5 IS AN ISO 9001 CERTIFIED COMPANY Style 005 FireLock® Rigid Coupling VICPlua with Vic-Plus® GasketSystem Gasket System PATENTED PRODUCT DESCRIPTION FireLock®Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves.By permitting the housings to slide on the angled bolt pads,rigidity is obtained. .. : _ The FireLock couplings provide rigidity for valveconnections,fire mains and long straight runs.Support and hanging requirements correspond to NFPA 13 Sprinkler Systems.Angle-pad design permits - assembly by remov ingone nut/bolt and swinging the housing over the gasket.This reduces components to handle during assembly;speeds and eases installation on pipe groovedto Victaulic specifications. Style 005 FireLock couplings with the Vic-PIusTM Gaske t Syste m are de signe dand recommended for use ONLY on fire protection systems. Patented Vic-Plus GasketSystem: Victaulic®now offers a gasket system which requires no field lubrication on wet pipe systems.The VicPIusTM System(patented)is dry,clean,and non-toxic.It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook(1-100)for supplemental lubrication requirements. IIlUI' x , ILII ® 0 ® 11 MOVds § LPC and VdS Approved, Request Victaulic / seenotes on page2. Exaggerated torclarity publication 10.01 for details. DIMENSIONS < Y > I<—Z—sl Dim ensions Pipe Size Inches/in m afrAM �rx�i+ Actual Max. Max. Allow. OA ir l Nominal Outside Work. EndPipe End Sep.f @ Bolt/NutAprx. = Diameter Diameter Press.§* Load* No.-Size Wgt.Ea. � „L _V I_ i Inches/Inches/inm Inches/Inches/inm PSI/kPa LbsJN InJm m Inches/Inches/inm X Y Z Lbs./kg 11/4 1.660 350 755 0.053 2.75 4.50 1.88 1.2 Rated forwetand dry sprinkler 32 _ 42,4 2413 3370 1,2 2 /e X 2/4 70 114 148 0,5 systems at 350 psi(2413 kPa) 11/2 1.900 350 990 0.052 3/8 X 2,/a 3.00 4.75 1.88 1.2 - 40 48,3 2413 4415 1,2 76 121 148 0,5 for 11/4 4"(32 100 mm)sizes 2 2.375 350 1550 0.073.50 5.25 1.88 1.6 and 300 psi(2068 kPa)for 50 60,3 2413 6900 1,7 2-3/8 X 21/2 89 133 148 0,7 41/4 8"(108 200 mm)sizes; 21/2 2.875 350 2270 0.074.00 5.75 1.88 1.9 3 Schedule 10 roll grooved or 65 73,0 2413 10110 1,7 2- /8 X 21/2 102 146 148 0,9 Schedule 40 cut or roll 3.000 350 2475 0.07 4.13 5.75 1.88 1.9 grooved steel pipe.Style 005 76,1 mm 76,1 2413 11010 1,7 2-3/8 X 21/2 105 146 148 0,9 is rigid and does not 3 3.500 350 3365 0.073 4.63 6.13 1.88 2.1 accommodate expansion, 80 88,9 2413 14985 1,7 2- /g X 2/2 118 156 148 1,0 contraction or angular 4 4.500 350 5565 0.163 5.75 7.25 2.13 3.1 deflection. 100 114,3 2413 24770 4,1 2- /a X 2/2 146 184 54 1,4 108,0 mm 4.250 300 4255 0.16 2 s/e X 21/2 5.63 7.25 2.13 3.1 108,0 2068 18940 4,1 143 184 54 1,4 5 5.563 300 7290 0.163 6.88 9.00 2.13 4.5 125 141,3 2068 32445 4,1 2- /2 X 2/4 175 229 54 2,0 5.250 300 6495 0.16 6.63 9.00 2.13 4.5 133,0 mm 133,0 2068 28900 4,1 2 1/2 X 23/a 168 229 54 2,0 5.500 300 7125 0.16 6.88 9.00 2.13 4.8 139,7 mm 139,7 2068 31715 4,1 2 1/2 X 23/4 175 229 54 2,2 6# 6.625 300 10340 0.16 3 8.00 10.00 2.13 5.0 150 168,3 2068 46020 4,1 2 /2 X 2/4 203 254 54 2,3 6.250 300 9200 0.16 7.63 10.00 2.13 5.5 159,0 mm 159,0 2068 40955 4,1 2-5/a X 41/4 194 254 54 2,5 6.500 300 9955 0.16 8.15 10.00 2.13 5.5 165,1 mm 165,1 2068 44295 4,1 2 1/2 X 23/4 207 254 54 2,5 P o 8.62519 2 68 78000 0.19 300 17525 2-5/8 X 41/4 10.2650 17 3343 2.63 15,3 1 *@§t Refer to notes on page 2. #Not available with Vic-Plus gasket system.Lubrication is required. 0 REGISTERED TRADEMARKOF VICTAULIC-0 COPYRIGHT 2004 VICTAULIC-PRINTED IN U.S.A. 1538 REV G Victaulic Company of America•Phone:1-800-PICK-VIC(1-800-742-5842)•Fax:610-250-8817•e-mail:pickvic@victaulic.com Victaulic Comp any of Canada•Phone:905-884-7444•Fax:905-884-9774•e-mail:viccanada@victaulic.com Victaulic Europe•Phone:32-9-381-1500•Fax:32-9-380-4438•e-mail:viceuro@victaulic.be Victaulic America Latina•Phone:610-559-3300•Fax:610-559-3608•e-mail:vical@victaulic.com jctaulic® Victaulic Asia Pacific•Phone:65-6235-3035•Fax:65-6235-0535•e-mail:vicap@victaulic.com 10.02 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request.. Housing Coating:Orange enamel • Optional:Hot dipped galvanized Gasket: • Grade"E"EPDM-Type A Vic-Plus GasketSyste mA (Violet color code). FireLock products havebeen Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure us- ing the Grade"E"Type A Vic-Plus Gasket System,requiring no field lubrication for most installation condi- tions. For dry services,Victaulic continues to recommend the use of Grade"E"Type A FlushSeal®Gasket.Contact Victaulic for details. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to-40°F(-40°C).Based on"typical"pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F(-18°C)and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water.Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has v oidsand/or cracks at the weld seams.Victaulic continues to recommend the use of FlushSeal gaskets for dry sery ices. LISTINGS/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated orking Pressure-PSI Rated Working Pressure-PSI Rated Working Pressure-PSI Pipe Size Pipe Size Pipe Size Sch. Inches UL ULC FM Sch. Inches UL ULC FM Sch. Inches UL ULC FM 5 11/4-3 175 175 175 EL 11/4-2 300 N/A N/A MT 11/4-2 300 N/A N/A 11/4-4 350 350 350 ET 11/4-2 300 N/A N/A STF 11/4-4 N/A N/A 300 10,40 Steady 5-8 300 300 300 EZ 4-6 300# N/A 300 Thd. 11/4-2 N/A N/A 300 BLT 11/4-2 300 300 N/A FF 11/4-4 N/A N/A 300 TF 3-8 N/A N/A 300 DF 11/4-4 300 300 300 GAL-7 11/4-2 300 N/A N/A WLS 11/4-2 300 300 N/A DT 11/4-2 300 300 N/A MLT 11/4-2 300 N/A N/A XL 11/4-3 300 300 300 EF 11/2-4 175(0 N/A 175 MF 11/4-4 300 N/A 300* *FM approved for sery icein 11/2-4"pipe. #UL Listed for sery ice up to 4"pipe only. @UL Listed for sery iceup to 3"only. PIPE SCHEDULE NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe BLT refers to Listed steel sprinkler pipe manufactured by Allied Tube&Conduit DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by Allied Tube&Conduit DT refers to Listed Dyna Thread steel sprinkler pipe manufactured by Allied Tube&Conduit EF refers to Listed/Approved Eddy Flow steel sprinkler pipe manufactured by Bull Moose Tube Co. EL refers to Listed Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. ET refers to Listed Eddythread 40 steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed EZ-Flow steel sprinkler pipe manufactured by Northwest Pipe&Casing Co. FF refers to Listed Fire-Flo steel sprinkler pipe manufactured by Youngstown Tube Co. GAL-7 refers to Listed steel sprinkler pipe manufactured by!DOD Systems,LLC MLT refers to Listed steel sprinkler pipe manufactured by Wheatland Tube Company MF refers to Listed Mega-Flow steel sprinkler pipe manfactured by Wheatland Tube Company MT refers to Listed Mega-Thread steel sprinkler pipe manufactured by Wheatland Tube Company STF refers to Listed Steady Flow steel sprinkler pipe manufactured by AMS Tube Corporation Steady Thread refers to Appproved steel sprinkler pipe manufactured by AMS Tube Corporation TF refers to Tex-Flow steel sprinkler pipe manufactured by Tex-Tube Company WLS refers to Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company XL refers to Listed XL or XL II steel sprinkler pipe manufactured by Allied Tube&Conduit Corp. NOTES *Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t For field installation only.FireLock Style 005 couplings are essentially rigid and do not accommodate expansion/contraction. Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. §Style 005 couplings are VdS and LPC Approved to 12 Bar(175 psi). WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. This product shall be manufactured by Victaulic Company.All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 2 Style 005 FireLock® Rigid Coupling FireLock® Fittings ✓ctaulic° 10.03 Material Specifications: 110111 Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. 1111)E i Fitting Coating: ❑ Orange enamel ❑ Red enamel in Europe, Middle East, Africa, and India O Optional: Hot dipped galvanized Approvals/Listings: c L us LPCB (vds] TP LISTED Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date • victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 ©2014 Victaulic Company.All rights reserved. 1 ictaulic° victaulic.com I FireLock® Fittings I Publication 10.03 Dimensions: k-CtoEl ,__ C 4\ -4 � to 4-� CtoE 4Y. u u c = to o0 010 E --(41 ---.7 I j l_t NO. 001 NO. 003 NO.002 No.006 No.001 No.003 No.002 No.006 90°Elbow 45°Elbow Straight Tee Cap Actual Approx. Approx. Approx. 7 Approx. Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. mm _ mm mm kg mm kg mm kg mm kg 11/4 1.660 _ _ _ _ _ _ 0.82 0.3 32 42.4 21 0.1 11 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 76.1 mm - - 76.1 76 1.5 57 1.1 76.2 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108 mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 - - 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 139.7 mm - - 139.7 124.0 5.6 82.6 3.7 124.0 6.9 159 mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 - - 158.8 140 - 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 mm - - 165.1 139.7 7.9 88.9 5.2 139.7 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 10.03 1539 Rev M Updated 12/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ictaulic° victaulic.com I FireLock® Fittings I Publication 10.03 Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' Nominal Outside No.002 Size Diameter Elbows Straight Tee inches inches No.001 No.003 mm mm 90°Elbow 45°Elbow Branch Run 11/4 1.660 32 42.4 - - - - 11 1.900 - - - - 40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE:When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. • Installation Note R eferenceshould always be made to the I-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks R eferto the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 10.03 1539 RevM Updated 12/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulic° - - - •1 11 .02 Mechanical-T® Bolted Branch Outlets : 1 VdS LPCB VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical-T®Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a "holefinder"locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE:Style 920 and Style 920N 411telilt housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet.Specify choice on order.Units are supplied painted with plated bolts.Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE) pipe.Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe.Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle w hen permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems,utilizes the Style 920 Mechanical-T in conjunction w iththe Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. • Optional:Hot dipped galvanized Gasket:(Specify choice*) • Grade"E"EPDM EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommendedfor cold and hot water service withinthe specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recom m endedfor petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recom mendedfor hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendationsonly.It should be noted that there are services for which these gaskets are not recom m ended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recom mendationsand for a listing of services which are not recommended. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirementsof ASTM A-449 and physical requirementsof ASTM A-183. • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL R IGHTS RESERVED. ICt.sUlilc REV_N 11.02_1 CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each anch Hole V I# VZ Female al Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y >- K Z 1 mm 920N kPa -0.00 mm mm mm mm mm mm kg kg r '1' 2 /'(a)a I 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 I-) 50 x 15 920N 3450 38.1 51 64 41 136 70 1.5 A' m /1 I f�11 3/4(a)0 920N 920N 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 --A0S- 20 3450 38.1 50 64 41 136 70 e1.5 T 1(a)0 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 y25 3450 38.1 47 64 41 136 70 1.4 1'/4(a)to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVEDOUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y K Z N 2 Yz Y(a)§0 920N 500 1.50 2.21 2.74 _ 1.82 5.64 2.75 3.0 x 65 5 3450 38.1 56 70 46 143 70 1.4 tPR11 3/4(a)§0 920N 500 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 V T 20 3450 38.1 55 70 46 143 70 1.4 A Ai k T iff9,,f 1 (a)§o 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 i >--- ---4 -t 4110 w25 920N 3450 38.1 52 70 46 143 70 1.4 yv 1 1/43t2(a)0 920N 5003450 44.5 1.75 2.3058 3.0076 3.2583 1.8246 6.29160 3.0076 3.51.7 3.21.5 FEMALE THREADED OUTLET 11/2 t(a)0 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 I 50.8 58 76 83 46 159 83 1.7 1.6 Y2(a) 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 76.1 x15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4(a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 any location wherea hole can be cut 20 _ 2065 38.1 56 70 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 11/4(a)o 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2(a)0 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 v2(a)n 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450kPa 3A(a)n920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe;also available for use 20 3450 38.1 63 78 - 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1/2"/50 x 15mm 1 Y4(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4"/200 x 100mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 11/2(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)11 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 31/2 2 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 x 50 920N 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N ho usings cannot be **Center o f run to engaged pipe end,female threaded outlet o nly(dimensio nsapproximate). mated to one another t Available with gro ovedo rfemale threaded o utlet.Specify cho iceo n o rder. to achieve crossconnections. # Centerofrun to end offitting. # Female threaded outlets are available to NPT and BSPT specificatio ns. @ See page 7 fo rFire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly o n o rder. (b)Fo r76.1 mm threaded o utlet,specify 21/2"BSPTclearly o n o rder. §Vds approved fo rfire protection services o LPCB approved fo rfire protection services 0 Approved fo ruse in China by Tianjin Approvals Co mpany. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt9UI1C® 11.02_2 REV_N CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Branch Hole V#H V# Female final Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. 4 Y > Z--* mm 920N kPa -0.00 mm mm mm mm mm mm kg kg t TABLE CONTINUED FROM PAGE 2 p� I-7 4x 1/2(a)a 920N 500 1.50 3.03 3.56 1 i 2.69 7.01 2.75 3.7 V 100 15 3450 38.1 77 90 68 178 70 1.8 45. ''''• ' 1311 1 irrR1 - 3/4(a)a 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 ' 20 3450 38.1 76 90 68 178 70 1.8 I- ib y 1(a)a 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 �L 25 3450 38.1 73 90 68 178 70 1.8 GR OOVEDOUTLET 1 Ya(a)to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y > r Z 2(a)to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 t PR 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 V T 2Yz(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 ri te. T I( 11 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 u 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 I I 3450 69.9 73 102 68 186 118 2.9 `� l� 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET - - 1'/4(a)a 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 108.0 x 32 920N 3450 44.5 78 96 67 194 78 2.3 11/2(a)a 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 2.3 any location wherea hole can be cut 2(a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 11/2(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 X 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe;also available for use 21/2(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 • Sizes from 2 x 1/2'750 x 15mm 3450 69.9 95 121 80 246 118 3.6 through 8 x 4"/200 x 100mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 133.0 x50 920N 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 920 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Centerofrun to engaged pipe end,female threaded outlet only(dimensio nsapproximate). Style 920 and Style 920N ho usings cannot be t Available with groovedo rfemale threaded outlet.Specify cho iceo n o rder. mated to oneanother # Centerofrun to end off itting. to achieve cro ssco nnectio ns. # Female threaded outlets are available to NPT and BSPTspecif icatio ns. @ See page 7 fo rFire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly o n order. (b)Fo r76.1 mm threaded o utlet,specify 21/2"BSPTclearly o n order. §Vds approved fo rfire protection services a LPCB approved fo rfire protection services 0 Approved fo ruse in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulice REV_N 11.02_3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each anch Hole V I# V t Female .1 Size 920 Diameter T** Thd. Grv. W Y Z Thd. Gr Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs Y > < Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg r l' 1 ^ TABLE CONTINUED FR OMPAGE3 4 + 139.7 x 1 YZ t 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 V 40 3450 50.8 96 114 84 209 83 3.2 Rs •"'""% til 1 f fR l 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 ' < e50 3450 63.5 95 114 84 209 99 4.1 1 1 o Ya(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 d1 6 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GR 00VEDOUTLET 11/2(a)to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 _130 130 96 232 83 2.4 2.3 2(a)to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 Y Z 2'/2 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 t PR 11 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 T 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 V ' .."-"'• ` 76.1 mm o 920 y 1uiisfil T l 3450 69.9 105 132 94 267 118 3.8 i FSU 3(a)t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 I I 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 + l� 4(a)to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 11/2(a) 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 159.0 x40 920N 3450 50.8 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location w herea hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 In the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 920 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500psi/3450kPa **Centerofrun to engaged pipe end,female threaded outletonly(dimensionsapproximate). on steel pipe;also available for use t Available with gro ovedo rfemale threaded o utlet.Specify cho iceo n o rder. with HDPE pipe t Centerofrun to end offitting. • Sizes from 2 x 1/2"/50 x 15mm # Female threaded outlets are available to NPT and BSPTspecifications. through 8 x 4°/200 x 100mm @ See page 7 fo rFire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly o n order. (b)Fo r76.1 mm threaded o utlet,specify 21/2"BSPT clearly o n order. §Vds approved fo rfire protection services u LPCB approved fo rfire protection services IMPORTANT NOTES: 0 Approved fo ruse in China by Tianjin Approvals Co mpany. Style 920 and Style 920N housings cannot be mated to one another to achieve cro ssco nnectio ns. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt9UI1C® 11.02_4 REV_N CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Hole V t V Female 'Branch al Size 920 Diameter T** Thd.. Grve. W Y Z Thd. Grv. hes or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y > z- m 920N kPa -0.00 mm mm mm mm mm mm kg kg - I TABLE CONTINUED FROM PAGE 4 4 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 a � 165.1 x 920N 25 3450 38.1 99 116 96 237 70 3.6 4o / o''''"• ' lilV� ill /� 1 7a 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 III i, 32 3450 44.5 113 130 96 237 83 3.8 y1 Y(a)tII 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 ii d-L 40 3450 50.8 112 130 130 96 237 83 3.8 GR OOVEDOUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 < Y z 3(a)t e 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 El 1 PR 80 3450 88.9 110 140 130 92 267 135 4.6 4(a)to 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 V Alil �� la, T 1 100 920 3450 114.3 97 146 137 92 267 159 4.8 LEI i FY -- 4, - 8 x 50 2(a)t 200 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 1 3450 69.9 138 157 159 122 316 114 5.3 5.3 01 21/2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 mm a 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location W here a hole can be cut 4(a)to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 s.7 **Centerofrun to engaged pipe end,female threaded outlet only(dimensio nsapproximate). • A pressure responsive gasket provides t Available with groovedo rfemale threaded outlet.Specify cho iceo n o rder. the seal # Centerofrun to end off itting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPTspecifications. Mechanical-T cross assemblies @ See page 7 fo rFire Protection approvals and pressure ratings.' • Pressure rated up to 500 psi/3450kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly ono rder. on steel pipe;also available for use (b)Fo r76.1 mm threaded o utlet,specify 21/2"BSPTclearly o n order. with HDPE pipe §Vds approved fo rfire protection services ❑LPCB approved fo rfire protection services • Sizes from 2 x 1/2'/50 x 15mm 0 Approved fo ruse in China by Tianjin Approvals Company. through 8 x 4"/200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N ho usings cannot be mated to each otherto achieve cro ssco nnectio ns. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulice REV_N 11.02_5 CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss betw een point(1)and (2)for the Style 920,920N and 929 Mechanical-T®fittings can best be expressed in term sof the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. ®2 Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for Cv 1K,Values: 4P = Q2 Where: Q=Flow(GPM) AP = Q2 Where: *AM 2Q=Flow(m3/hr) �� T11 CV AP=Pressure Drop(psi) KVz AP=Pressure Drop(Bar) _________ Q = C„ x A CV=Flow Coefficient Q = K„ x /4P K =Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213,Sec.16) OUTLET SIZE (C=120)t FT Cv/Kv Values NOMINAL ACTUAL DIAMETER O.D. In/mm In/mm GROOVED THREADED GR 00VED THREADED yz 0.840 11 15 21.3 9.4 3/4 1.050 16 20 26.7 13.7 1 1.31521 25 33.7 3 1.8 1 y4 1.660 50 48 32 42.7 5 1/2 6 42.9 41.1 1 Yz 1.900 53 53 40 98.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10 1/2 96 89.1 2 Yz 2.875 119 150 65 73.0 20 12/z 102 128.5 76.1 mm 3.000 16* 161 76.1 138.1 3 3.500 249 237 80 88.9 14 15/z 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient offriction is 120. *Pipe with a wall thickness of0.165in./4.2mm. —1"FireLock''Innovative Groove System(IGS)outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2017 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt9UI1C® 11.02_6 REV_N