Loading...
HomeMy WebLinkAboutB17-0264_A6.2 Details_1501690200.pdfEXIST. DECK STRUCTURE TO REMAIN. V.I.F. T.O. PLYWOOD RE: FLOOR PLAN EXTERIOR INTERIOR 3/4" PLYWOOD 3" STONE PATIO ASSEMBLY - APPROX. 1 1/2" OF STONE OVER 1 1/2" OF GROUT W/ SNOWMELT TUBING IN GROUT OVER DRAINAGE MEDIUM 2X P.T. SLEEPERS RIPPED TO 1/8" / 12" SLOPE @ TOP. 3" 1 1/2"1 1/2" 1" PISTOL CUT EDGE STONE EXISTING WATERPROOFING TO BE REPLACED W/ HOT LIQUID APPLIED W.P. MEMBRANE RE: COVER SHEET EXISTING SUBFLOOR TO REMAIN; VIF. REPLACE AS REQ'D SLOPE RE: PLANS EXIST. STONE VENEER LAP NEW W.P. MEMBRANE OVER EXIST. WALL WATERPROOFING 18" MIN. LIFT AND SLIDE DRAINAGE TUBE, DRAIN AND ROUTE TRACK PIPE THROUGH STONE DECK ASSEMBLY TO WEEP @ DECK PERIMETER EXTERIOR INTERIOR 1 1/2"1 1/2" SLOPE RE: PLANS NEW W.P. DECK MEMBRANE CONTINUOUS UP WALL 18" MIN. - EXIST. W.P. DECK MEMBRANE TO BE REMOVED SEE DETAIL 1/A6.2 FOR TYP. STONE DECK NOTES T.O. PLYWOOD RE: FLOOR PLAN 3" HOUSE INTERIOR EXIST. WALL / FLOOR / DECK STRUCTURE TO REMAIN EXISTING SUBFLOOR TO REMAIN; VIF. REPLACE AS REQ'D 3D DRAINAGE MATERIAL CONT. @ WALL & LAP OVER FLASHING @ BOTTOM WALL SUCH THAT DRAINAGE MEDIUM CAN DRAIN RE: SPEC PROVIDE WEEP SCREED @ B.O. STUCCO COPPER FLASHING W/ HEMMED EDGE @ B.O. STUCCO FINISH REMOVE EXISTING STUCCO ABOVE DECK TO INSTALL NEW W.P. MEMBRANE AND DRAINAGE APPROX. 18" UP WALL. SELF ADHERED FLASHING OVER T.O. COPPER FLASHING, CONTINUOUS UNDER NEW AIR & WATER INFILTRATION BARRIER MIN 6" EXIST. AIR AND WATER INFILTRATION BARRIER LAPS OVER T.O. NEW AIR & WATER INFILTRATION BARRIER AND NEW W.P. DECK MEMBRANE MINIMUM 12". NEW AIR & WATER INFILTRATION BARRIER OVER FLASHING MIN. 6" APPROX. CUT @ EXISTING STUCCO NEW EXISTING EXTERIOR INTERIOR 1/8" SLOPE MIN. RE: PLANS W.P. MEMBRANE CONTINUOUS UNDER DOOR THRESHOLD AND TURNS UP 1/2" @ FLASHING @ INTERIOR OF DOOR SEE DETAIL 1/A6.2 FOR TYP. STONE DECK NOTES T.O. PLYWOOD RE: FLOOR PLAN INTERIOR EXIST. WALL / FLOOR / DECK STRUCTURE TO REMAIN EXISTING SUBFLOOR TO REMAIN; VIF. REPLACE AS REQ'D 2 3/4" LINE OF TRACK @ HEAD / JAMB FUR OUT SILL W/ P.T. BLOCKING PISTOL CUT STONE @ SILL 2 1/4" EXISTING WATERPROOFING TO BE REPLACED W/ HOT LIQUID APPLIED W.P. MEMBRANE RE: COVER SHEET V.I.F. V.I.F. 3/4" PLYWOOD OVER 2X P.T. SLEEPERS @ 2'-0" O.C. W/ TOP RIPPED TO SLOPE PER PLAN 3" STONE FLOOR ASSEMBLY - APPROX. 1 1/2" OF STONE OVER 1 1/2" OF GROUT W/ SNOWMELT TUBING SHIM AS REQ'D STL. ANGLE FLASHING FOR W.P. MEMBRANE TO LAP OVER NON-SHRINK GROUT BED RE: SPEC. FLUSH DRAINAGE TRACK W/ DRAIN TUBES ROUTED TO WEEP @ PERIMETER OF STONE DECK CUT BACK EXISTING FLOOR AS REQ'D. EXTERIOR INTERIOR 3 3/8" 2 5/8" 10 15/16" EXISTING WINDOW TO REMAIN NEW OXX SLIDING PATIO DOOR NEW FURRING SEALANT JOINT AND BACKER ROD LAP AIR AND WATER INFILTRATION BARRIER OVER SELF-ADHERED FLASHING SELF-ADHERED FLASHING LAPS OVER DOOR FRAME 1/4" 1/2" 3 7/8" 1/2" 5 1/2" 4 1/2" 5 1/2" APPROX. LINE OF EXIST. STUCCO NEW INTERIOR TRIM TO MATCH EXIST. 2 1/2" 2 1/2" EXIST. WINDOW R.O. 1" NEW LIFT AND SLIDE R.O. 4 1/2" NEW STUCCO TO MATCH EXIST. TRIM TO MATCH EXIST. DOUBLE STICK FLASHING BY WINDOW MANUFACTURER/INSTALLER ATTACHED TO BACK OF DOOR AND SEALED TO EXT. WALL 1/4" EXISTING TRIM EXISTING WALL FRAMING NEW STUCCO J-MOLD @ REPAIRED STUCCO TYP. 3 1/2" 7 1/2" EXIST. 1X6 T&G SOFFIT TO BE REMOVED EXISTING JOISTS @ 2'-0" O.C. CUT TO CREATE FLAT BOTTOM SOFFIT NEW 4X8 JOISTS @ 4'-0" O.C. RE: STRUCT. NOTCH AROUND OR CUT BACK EXISTING FASCIA ABOVE NEW TRELLIS AND REPLACE TO MATCH EXISTING BETWEEN JOISTS RE: STRUCT. 1/2" NEW 1X6 T&G SOFFIT TO MATCH EXIST. 1/2" NEW MC12X31 SISTERED TO EXIST. GLULAM RE: STRUCT. 1/2" 3 7/8" 1/2" 5 1/2" FUR OUT EXIST. WALL TO ACCOMOCDATE 3 PANEL LIFT AND SLIDE NEW WOOD HEAD TRIM TO MATCH EXIST. 11" 1" PROVIDE FRAMING AS NECESSARY FOR FLAT BOTTOM SOFFIT 4x10 TIMBER LEDGER RE: STRUCT. DOUBLE STICK FLASHING BY WINDOW MANUFACTURER/INSTALLER ATTACHED TO BACK OF DOOR AND SEALED TO EXT. WALL LAP AIR AND WATER INFILTRATION BARRIER OVER T.O. SELF-ADHERED FLASHING SELF ADHERED FLASHING LAPS OVER DOOR FRAME 1/4" 3D DRAINAGE MATERIAL CONT. @ WALL & LAP OVER FLASHING COPPER FLASHING EXTENDS UP BEHIND W.P. MEMBRANE MIN. 4" CONT. BUG SCREEN STAPLED TO UNDERSIDE OF SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE 1/2" MIN. VENT @ T.O. WALL COPPER FLASHING COPPER FLASHING US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 5/15/2017 8:40:47 AM As indicated PRECOURT MILL CREEK 328 MILL CREEK CIRCLE VAIL CO 81657 A6.2 DETAILS 5-15-17 CPM HB 5-15-17 PERMIT SET REVISION SCHEDULE # DESCRIPTION DATE 1 1/2" = 1'-0" 1 TYPICAL FLAGSTONE DECK ASSEMBLY @ EDGE 1 1/2" = 1'-0" 2 FLAGSTONE DECK DETAIL @ EXTERIOR WALL 3" = 1'-0" 4 WEILAND SILL DETAIL @ DECK 3" = 1'-0" 3 WEILAND JAMB DETAIL @ CORNER 3" = 1'-0" 5 ROOF/ PERGOLA INTERSECTION DETAIL @ WEILAND HEADER 08/02/17