HomeMy WebLinkAboutB17-0293_A-100B_1503670800.pdfO A TE T E PV FEC DEMO WALLS OF EXISTING TOILET ROOM DEMO EXISTING BATHROOM WALL AND DOOR REMOVE EXISTING DOOR AND FRAME AND PORTION OF WALL SALVAGE DOOR AND FRAME FOR RELOCATION. DEMO EXISTING ENTRY CLOSET REMOVE EXISTING DOOR AND RELOCATE DOOR OPENING DEMO EXISTING KITCHEN. SALVAGE ALL APPLIANCES FOR POSSIBLE REUSE. RE: I- SERIES DEMO EXISTING PILASTERS AND SOFFIT REMOVE AND REPLACE ALL EXISTING PLUMBING FIXTURES, BATH VANITY, GLASS SHOWER ENCLOSURE AND DOORS DEMO CLOSET DOORS AND WALL REMOVE EXISTING DECORATIVE LIGHT FIXTURE AND REPLACE WITH NEW REMOVE EXISTING DECORATIVE LIGHT FIXTURE AND REPLACE WITH NEW. REMOVE EXISTING DECORATIVE LIGHT FIXTURE AND REPLACE WITH NEW. REMOVE EXISTING CLOSET DOORS AND DEMO SHELF AND ROD REMOVE EXISTING DECORATIVE LIGHT FIXTURE AND REPLACE WITH NEW. REMOVE AND REPLACE ALL EXISTING PLUMBING FIXTURES, BATH VANITY, GLASS SHOWER ENCLOSURE AND DOORS REMOVE ALL EXISTING LIGHTING FIXTURES AND REPLACE WITH NEW DOWNLIGHTS. REMOVE AND REPLACE ALL EXISTING PLUMBING FIXTURES, BATH VANITY, GLASS SHOWER ENCLOSURE AND DOORS REMOVE ALL EXISTING LIGHTING FIXTURES AND REPLACE WITH NEW DOWNLIGHTS. REMOVE EXISTING CLOSET DOORS AND DEMO SHELF AND ROD REMOVE EXISTING DECORATIVE LIGHTING FIXTURES REMOVE EXISTING DECORATIVE LIGHTING FIXTURE GENERAL NOTE: RE: I-SERIES, ELEC, AND PLUMBING FOR ALL DETAILS, FINISH AND ADDITIONAL INFORMATION REMOVE ALL EXISTING LIGHTING FIXTURES AND REPLACE WITH NEW DOWNLIGHTS. REMOVE EXISTING DOORS KITCHEN LAUNDRY BEDROOM 2 BEDROOM 3 LIVING BATH 2 BATH 3 MASTER BATH ENTRY MASTER BEDROOM DINING DEMO OBJECT EXISTING WALL DEMO PLAN LEGEND AREA NOT IN CONTRACT PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 8/2/2017 2:12:44 PM C:\Revit Local Files\116194.00_Four Seasons Vail__A17_Central_kadams.rvt As indicated FOUR SEASONS RESORT AT VAIL ONE VAIL ROAD VAIL, CO 81657 116194.00 OZ OZ 2017/08/02 ISSUE FOR BUILDING PERMIT ROOM 6103 - DEMO PLAN A-100B FOUR SEASONS RESORT AT VAIL OZ 1/4" = 1'-0" 1 CONDO DEMO PLAN DEMOLITION PLAN NOTES 1 REFER TO "I" SERIES DRAWINGS FOR ALL FINISH INFORMATION, INCLUDING, BUT NOT LIMITED TO WALLS,FLOORS, CEILINGS, TRIM, DOORS, MILLWORK DETAILS, ACCESSORIES AND FF&E. 2 EXISTING INFORMATION SHOWN ON THE DRAWINGS IS BASED ON LIMITED FIELD OBSERVATIONS AND/OR INFORMATION PROVIDED BY THE OWNER. OZ ARCHITECTURE IS NOT RESPONSIBLE FOR THE ACCURACY OF INFORMATION OR THE ADEQUACY, SAFETY, AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. THE GC SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS NOT WITHSTANDING ANY INFORMATION SHOWN, OR NOT SHOWN, ON THE CONTRACT DOCUMENTS. SHOULD ANY DISCREPANCIES BE FOUND, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 3 THE GC SHALL MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE AND FIREPROOFING U.N.O. 4 IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING CONSTRUCTION, NOTIFY THE OWNER AND ARCHITECT IMMEDIATELY AND AWAIT FURTHER INSTRUCTIONS. 5 WORK TO BE REMOVED IS ILLUSTRATED IN DASHED LINE-WORK. EXISTING CONSTRUCTION TO REMAIN IS ILLUSTRATED IN LIGHT LINE-WORK. ALL ITEMS FOR REMOVAL MAY NOT BE SPECIFICALLY NOTED. REMOVE ITEMS AS NECESSARY FOR THE COMPLETION OF THE WORK. 6 SEE ENGINEERING DRAWINGS FOR THE REMOVAL OF SPECIFIC STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE ALARM SYSTEMS. 7 WHERE THE TERM "REMOVE" OR “DEMOLISH” IS USED, THE GC SHALL REMOVE ITEM FROM THE SITE AND LEGALLY DISPOSE OF. 8 WHERE THE TERM "SALVAGE" IS USED, THE GC SHALL REUSE THE ITEM ON THIS PROJECT OR RETURN TO THE OWNER. 9 WHERE THE TERM "REMOVE AND REINSTALL" IS USED, THE GC IS TO DETACH ITEM FROM EXISTING CONSTRUCTION, PREPARE AND CLEAN ITEM FOR REUSE, AND REINSTALL WHERE INDICATED. 10 WHERE THE TERM "EXISTING TO REMAIN" IS USED, THE EXISTING ITEMS ARE NOT TO BE REMOVED. PROTECT FROM DAMAGE AS REQUIRED. THE GC IS TO REPLACE OR REPAIR ITEMS DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 11 SALVAGE MECHANICAL EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, CABINETS, AND LIGHT FIXTURES FOR REINSTALLATION. STORE SALVAGEABLE MATERIALS IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIAL AND DEBRIS SHALL BE DISPOSED OF BY THE GC. 12 WHERE MECHANICAL, ELECTRICAL, AND PLUMBING DEVICES ARE REMOVED, ABANDONED PIPING AND/OR CONDUITS SHALL BE CAPPED BELOW THE FLOOR, INSIDE THE PARTITION, OR ABOVE THE CEILING AND AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. UNUSED WIRING IS TO BE REMOVED BACK TO PANEL BOXES. PATCH AND REPAIR FINISHES AS REQUIRED TO MATCH SURROUNDING FINISHES. BLANK COVER PLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE U.N.O. 13 EXISTING CONCRETE SLAB DAMAGED DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED TO A CONDITION SUITABLE FOR NEW FINISHES. 14 PREPARE EXISTING WALLS FOR NEW FINISHES. REMOVE NAILS, PINS, TAPE, POSTERS, ETC.; FILL ALL HOLES; AND PREPARE SURFACES FOR PAINT OR WALLCOVERING. 15 REMOVE BASE IN AREAS WHERE FLOORING IS BEING REMOVED U.N.O. 16 PATCH AND REPAIR FLOOR AND PARTITION FINISHES WHERE INTERSECTING PARTITIONS HAVE BEEN REMOVED. MATCH ADJACENT SURFACE FOR FINISH, COLOR, AND TEXTURE. 17 COORDINATE UTILITY SHUT-DOWNS WITH BUILDING OWNER. 18 FOLLOW RECYCLING PROCEDURES FOR ITEMS TO BE REMOVED AS REQUIRED FOR LEED CERTIFICATION AND/OR BY THE AUTHORITY HAVING JURISDICTION. 0' 1' 4' 8' 16' 2' 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® 08/25/17