Loading...
HomeMy WebLinkAboutB17-0293_A-102B_1503670800.pdfTE PV FEC TV 3' - 7" 9' - 10 1/2" 11' - 8" 5' - 11 1/2" BEDROOM 4 13-5X11-8 CLOSET BATH 4 9-1X5-6 2' - 3" ALIGN 4' - 9" 5' - 1 1/2" 13' - 6" 4' - 7" 9' - 6" 23E 23E 23E 23E 26E 18" MIN. KITCHEN LAUNDRY MASTER BEDROOM BEDROOM 2 BEDROOM 3 RE: I-SERIES FOR ALL NEW FINISH INFORMATION 3' - 0" MATCH EXISTING WALL ASSEMBLY AT WALL INFILL 23E NEW GLASS WALL & DOOR RE: I-SERIES 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 LIVING BATH 2 BATH 3 MASTER BATH ENTRY CLOSET EQ EQ 22" MIN 48" MIN 12" MIN 18" MIN. 60" MIN. 1' - 11 1/2" 2' - 2" 2' - 2" 6' - 3 3/4" 5' - 6" NEW PLUMBING FIXTURES RE: I-SERIES & MECH. NEW PLUMBING FIXTURES RE: I-SERIES & MECH. EXISTING WALL NEW WALL FLOOR PLAN LEGEND AREA NOT IN CONTRACT PARTITION - STC 35-39 WITH 1-5/8" STUD - PARTITION WIDTH = 2- 7/8" 26 - 22 - 21 - 23 - WITH 2-1/2" STUD - PARTITION WIDTH = 3- 3/4" WITH 3-5/8" STUD = PARTITION WIDTH = 4- 7/8" WITH 6" STUD - PARTITION WIDTH = 7 1/4" PARTITION PARTITION PARTITION GYP BD METAL STUD RUNNER CHANNEL SEALANT, EACH SIDE 1/2" FLOOR LINE GA WP-1340 FOR 1-HOUR RATING WHERE OCCURS CONCRETE DECK PARTITION HEAD TO STRUCTURE PARTITION HEAD TO SUSP CLG - - F - - E METAL STUD, NOT ATTACHED TO CEILING TRACK GYP BD DRYWALL SCREW ACOUS SEALANT 3" DEEP-LEG TRACK 6" (NTS) 1" 1 1/2" L-BEAD, TYP EA SIDE FOAM GASKET RUNNER CHANNEL ATTACHED TO CEILING GRID GYP BD METAL STUD SUSPENDED CEILING 1" SUSP CLG, W.O., RE: CEILING PLAN USER NOTE (DELETE IN DWG): THIS DETAIL ALLOWS FOR 1" MOVEMENT. INCREASE 1" DIMENSION TO 1-1/2" IF GREATER MOVEMENT IS REQ'D. 9'-2" 8'-0" 8'-0" 7'-6" RE: I-SERIES FOR ALL NEW FINISH INFORMATION PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 8/2/2017 2:12:47 PM C:\Revit Local Files\116194.00_Four Seasons Vail__A17_Central_kadams.rvt As indicated FOUR SEASONS RESORT AT VAIL ONE VAIL ROAD VAIL, CO 81657 116194.00 OZ OZ 2017/08/02 ISSUE FOR BUILDING PERMIT ROOM 6103 - FLOOR PLAN & RCP A-102B FOUR SEASONS RESORT AT VAIL OZ 1/4" = 1'-0" 1 ROOM 6103 FLOOR PLAN DOOR SCHEDULE DOOR NUMBER DOOR HARDWA RE SET NO. FRAME COMMENTS PANEL TYPE LEAF QUANTITY LEAF WIDTH OPENING WIDTH HEIGHT THICKNES S MATERIAL FINISH FRAME TYPE MATERIAL FINISH WALL THICKNES S HEAD JAMB 101 F 1 2' - 6" 2' - 6" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES HEIGHT TO MATCH EXISTING DOOR OPENINGS 102 F 1 2' - 10" 2' - 10" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES NEW DOOR IN EXISTING WALL - VERIFY WALL THICKNESS. HEIGHT TO MATCH EXISTING DOOR OPENINGS 103 F 1 2' - 10" 2' - 10" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES EXISTING OPENING - VERIFY ALL DIMENSIONS ON SITE 104 F 1 2' - 10" 2' - 10" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES EXISTING OPENING - VERIFY ALL DIMENSIONS ON SITE 105 F 1 2' - 10" 2' - 10" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES EXISTING OPENING - VERIFY ALL DIMENSIONS ON SITE 106 F 1 2' - 10" 2' - 10" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES EXISTING OPENING - VERIFY ALL DIMENSIONS ON SITE 107 F 1 3' - 0" 3' - 0" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES HEIGHT TO MATCH EXISTING DOOR OPENINGS 108 F 1 3' - 0" 3' - 0" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES HEIGHT TO MATCH EXISTING DOOR OPENINGS 109 F 1 3' - 0" 3' - 0" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES HEIGHT TO MATCH EXISTING DOOR OPENINGS 110 F 1 3' - 0" 3' - 0" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 7 1/4" RE: I-SERIES RE: I-SERIES HEIGHT TO MATCH EXISTING DOOR OPENINGS 111 F 1 3' - 0" 3' - 0" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES EXISTING OPENING - VERIFY ALL DIMENSIONS ON SITE 112 F 2 2' - 0" 4' - 0" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES EXISTING OPENING - VERIFY ALL DIMENSIONS ON SITE 113 F 2 2' - 0" 4' - 0" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES EXISTING OPENING - VERIFY ALL DIMENSIONS ON SITE 114 F 2 1' - 11" 3' - 10" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES NEW DOOR IN EXISTING WALL - VERIFY WALL THICKNESS. HEIGHT TO MATCH EXISTING DOOR OPENINGS 115 F 2 1' - 11" 3' - 10" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES NEW DOOR IN EXISTING WALL - VERIFY WALL THICKNESS. HEIGHT TO MATCH EXISTING DOOR OPENINGS NOTE: SEE I-SERIES SHEET I-12-705 THROUGH I-12-707 FOR DOOR ELEVATIONS AND DETAILS. FLOOR PLAN NOTES 1 REFER TO "I" SERIES DRAWINGS FOR ALL FINISH INFORMATION, INCLUDING, BUT NOT LIMITED TO WALLS,FLOORS, CEILINGS, TRIM, DOORS, MILLWORK DETAILS, ACCESSORIES AND FF&E. 2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OF CONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOW U.N.O. 3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONS DESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED. 4 METAL STUD PARTITIONS ARE TYPE 23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O. 5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O. 6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OF PARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINT ASSEMBLIES. 7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE, THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGN U.N.O. 8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDE JAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENT PERPENDICULAR PARTITION. 9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THE FIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS IN ACCORDANCE WITH IBC CHAPTER 7. 10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION. 11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSED CONSTRUCTION. 12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK, MILLWORK AND OTHER BUILT-IN ITEMS. 13 REFER TO I-SERIES FOR MOUNTING HEIGHTS OF ACCESSORIES 14 REFER TO I-SERIES FOR ALL DIMENSIONS NOT SHOWN 0' 1' 4' 8' 16' 2' 1/4" = 1'-0" 3 ROOM 6103 RCP 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® 08/25/17