HomeMy WebLinkAboutB17-0293_E-105_1507140025.pdfMASTER BEDROOM BEDROOM 2 LAUNDRY KITCHEN BEDROOM 3 BEDROOM 4 ENTRY TV SCALE: ROOM 6103 ELECTRICAL PLAN 1/4" = 1'-0" J J J +44" T J +12" +50" J T +60" +12" J +50" +12" T +60" J J +65" +52" J +65" +52" J +65" +52" J +50" J +12" J J +65" +52" T +12" +60" T +60" CK CK TV TV TV CH +12" +24" +12" +12" +12" +12" +12" +12" +12" +12" +12" +12" +12" TV TV (E)DISP J (E) STEAM GENERATOR FLAG NOTES: 1 PROVIDE 20A, 120V ELECTRICAL FEED TO JUNCTION BOX FOR ELECTRIC MIRROR WITH INTEGRAL TV. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER SUBMITTAL PRIOR TO ROUGH-IN. PROVIDE 20A, 120V ELECTRICAL FEED TO JUNCTION BOX FOR MIRROR. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER SUBMITTAL PRIOR TO ROUGH-IN. PROVIDE 20A, 120V ELECTRICAL FEED TO JUNCTION BOX FOR NIGHTLIGHT LOCATED BELOW VANITY LIGHT. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER SUBMITTAL PRIOR TO ROUGH-IN. PROVIDE 20A, 120V ELECTRICAL FEED FOR MOTORIZED DRAPERY. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER SUBMITTAL PRIOR TO ROUGH-IN. PROVIDE 20A, 120V ELECTRICAL FEED FOR SAFE. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER SUBMITTAL PRIOR TO ROUGH-IN. PROVIDE PNUEMATIC PUSH BUTTON TO OPERATE GARBAGE DISPOSAL. COORDINATE EXACT LOCATION AND INSTALLATION WITH ARCHITECT AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. PROVIDE 30A, 208V RECEPTACLE FOR OVEN. REUSE EXISTING ELECTRICAL CIRCUIT SERVING THIS AREA TO SERVE NEW RECEPTACLE. REPLACE EXISTING 42-SPACE PANEL WITH NEW 54-SPACE PANEL. REFER TO ELECTRICAL ONE-LINE DIAGRAM ON SHEET E-001 FOR MORE INFORMATION. NOT USED. PROVIDE DUPLEX RECEPTACLE WITH (2) USB CHARGING PORTS. RECEPTACLE SHALL BE MOUNTED HORIZONTALLY ADJACENT TO LIGHTING CONTROL KEYPAD SHOWN ON EL-105. 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO LIGHTING DESIGN PLANS AND SPECIFICATIONS FOR WORK ASSOCIATED WITH THE LIGHTING AND LIGHTING CONTROL SYSTEMS. 5. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 6. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 7. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 8. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 9. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 10. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 11. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 12. ALL EXISTING DEVICES ARE NOTED WITH (E). RESIDENTIAL DWELLING UNIT NOTES: C (E)W/D (E)'PP-RC6.3' +38" +38" +60" +38" J SAFE 2 2 J 3 3 4 +60" 4 4 2 J 5 5 5 4 J 5 J 3 3 2 J 4 5 +12" +12" +44" SAFE SAFE +44" J 3 2 4 REF/FRZR OVEN 40,42 WARMING DRWR COFFEE MAKER MW DW 6 +44" 6 COOKTOP 7 7 SAFE (E) (E) (E) (E) C (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) C (E) (E) (E) FC 1 1. ALL DEVICES IN UNIT 6103 SHALL BE CIRCUITED TO PANEL 'PP-RC6.3' 2. METER PANEL 'PP-RC6.3' FOR 30-DAYS PER NEC 220.87 TO DETERMINE AVAILABLE LOAD CAPACITY. IT IS ASSUMED AT TIME OF PERMIT, PANEL 'PP-RC6.3' HAS SUFFICIENT CAPACITY FOR ADDED LOADS. ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL ENGINEER WITH METERED DATA PRIOR TO INSTALLATION OF ELECTRICAL SYSTEMS TO VERIFY SUFFICIENT CAPACITY IN PANEL. 3. FIRE ALARM SCOPE LIMITED TO REMODEL PORTION OF BUILDING ONLY. FIRE ALARM SYSTEM SHALL BE DESIGN/BUILD BY CONTRACTOR. FIRE ALARM DEVICES SHOWN ON PLAN ARE FOR DESIGN INTENT. FINAL DESIGN RESPONSIBILITY BY DESIGN/BUILD CONTRACTOR. NOTES: (E) 8 8 (E) 8 +38" 8 8 8 8 (E) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 20 20 20 20 1 3 5 7 7 9 7 9 7 7 7 20 20 20 20 20 7 7 9 9 9 9 9 11 11 11 11 27 27 27 27 27 33 33 35 37 37 37 37 37 37 37 39 39 39 39 41 41 41 41 9 9 20 H H H H H F CO CO CO CO (E) (E) (E) (E) (E) (E) H 10 11 11 8 11 8 11 8 11 8 11 8 11 8 11 8 11 1 1 1 1 1 1 1 1 1 1 1 PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: As indicated FOUR SEASONS RESORT AT VAIL ONE VAIL ROAD VAIL, CO 81657 8203.11 2017/09/05 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\ROOM 6103\8203.11E105.DWG 09.19.17 9:41:08 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 ROOM 6103 ELECTRICAL PLAN E-105 BAS MAS MAS 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® 10/04/17