Loading...
HomeMy WebLinkAboutB17-0293_E-300_1507140026.pdfNO SCALE TYPICAL DEVICE ALIGNMENT EQ EQ 6"MIN. ℄ ℄ ℄ DOOR WINDOW EQ EQ ℄ LIGHTING CONTROL ℄ ℄ OFFSET COMMUNICATIONS DEVICES FROM POWER DEVICES TO EITHER OPPOSITE SIDE OF STUD BAY, OR ADJACENT STUD BAY. NOTES: 1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. EQ BACKSPLASH ABOVE COUNTER DEVICE RECEPTACLE COUNTERTOP EQ FINISHED FLOOR FINISHED CEILING 6" MIN. 20" MAX. ALIGN DEVICES (OUTLETS, CONTROLS, ETC.) VERTICALLY. DO NOT VERTICALLY ALIGN POWER AND COMMUNICATIONS DEVICES SIMULTANEOUSLY. 18" 48"64" 78" 90" 78" 64" 90" 6"MIN FIRE ALARM DEVICES 48" ELECTRICAL DEVICES 96" NOTES: 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. WALL-MOUNT NO SCALE TYPICAL DEVICE MOUNTING HEIGHTS OC D LV S CB C TS TC ANN FACP S H S H F 120" MAX. 80" MIN. 96" MAX. TOP OF DEVICE 9'-0"+ CEILING 8'-0" CEILING TOP OF CABINET TOP OF CABINET TOP OF DEVICE CL OF DEVICE TOP OF DEVICE TOP OF CABINET TOP OF CABINET BOTTOM OF DEVICE MINIMUM, TOP OF DEVICE FINISHED FLOOR FINISHED CEILING 18" TOP OF DEVICE 48" MINIMUM, TOP OF DEVICE BOTTOM OF DEVICE TOP OF CABINET TOP OF CABINET 90" 6"MIN. 96" NOTES: 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. TYPICAL DEVICE MOUNTING HEIGHTS I I CR FINISHED FLOOR 48" 84" FINISHED CEILING 90" 78" 64" 24" NO SCALE I WALL-MTD CABINET CPU APS ACP K C V CT CK M AV TV S ANN FACP S H S H F 80" MIN. 96" MAX. 120" MAX. CL OF DEVICE CL OF DEVICE TOP OF DEVICE TOP OF CABINET 8'-0" CEILING 9'-0"+ CEILING CL OF DEVICE LOW VOLTAGE DEVICES FIRE ALARM DEVICES PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: As indicated FOUR SEASONS RESORT AT VAIL ONE VAIL ROAD VAIL, CO 81657 8203.11 2017/09/05 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\ROOM 6103\8203.11E300.DWG 09.19.17 9:41:26 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 ELECTRICAL DIAGRAMS E-300 BAS MAS MAS 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® 10/04/17