HomeMy WebLinkAboutB17-0293_EL-105_1503670800.pdfMASTER BEDROOM BEDROOM 2 LAUNDRY KITCHEN BEDROOM 3 BEDROOM 4 ENTRY TV SCALE: ROOM 6103 LIGHTING PLAN 1/4" = 1'-0" 12-LT-05 12-LT-02 12-LT-10 12-LT-10 SJ SJ SJ SJ SJ SJ 12-LT-10 Q Q D4A HD-111 K K D4A B1 K B1 K B1 K K D4A K D4A K D4A K D4A K D4A K D4A K F2 K B1 K F2 K A1 K B2 K OS OS OS OS OS Q F2 K F2 K HD 112 K HD 110 K LA-105 LA-101A LA-101A LA-101A B2 K FLAG NOTES: 1 LIGHTING CONTROL PANEL AND DIMMING PANEL. 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO LIGHTING DESIGN PLANS AND SPECIFICATIONS FOR WORK ASSOCIATED WITH THE LIGHTING AND LIGHTING CONTROL SYSTEMS. 5. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 6. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 7. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 8. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 9. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 10. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 11. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 12. ALL EXISTING DEVICES ARE NOTED WITH (E). RESIDENTIAL DWELLING UNIT NOTES: 1 1 1 1 LA-104 LA-103 LA-104 LA-104 LA-104 LA-104 LA-103 LA-104 LA-103 LA-103 LA-104 LA-104 LA-104 LA-103 LA-104 LA-102 LA-101B 1. ELECTRICAL CONTRACTOR SHALL LOCATE ALL NECESSARY POWER SUPPLIES FOR LED LIGHT STRIP FIXTURES IN AN ACCESSIBLE LOCATION. COORDINATE EXACT LOCATION WITH LIGHTING DESIGNER PRIOR TO ROUGH-IN. REFER TO LUMINAIRE SCHEDULE ON SHEET E-001 FOR POWER SUPPLY SPECIFICATION. 2. REFER TO DRAWING E-007 OF THE FOUR SEASONS DESIGN STANDARDS AND LUTRON DRAWINGS IN CONSTRUCTION SET FOR LIGHTING CONTROL INTENT. NOTES: LA-101A LA-101A LA-101A LA-101A LA-101A LA-101A LA-101A LA-101A LA-101A LA-101A LA-101B LA-101B LA-102 LA-102 LA-102 LA-101A LA-101A LA-101A LA-101A LA-101A LA-101B LA-101B LA-102 LA-101A LA-101B LA-101A LA-101A LA-101A LA-101A LA-101A LA-101B LA-101B LA-101B LA-101A LA-102 (E)'PP-RC6.3' 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 LA-101A 43 LA-101A 43 LA-101A 43 43 43 LA-101A 43 43 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: As indicated FOUR SEASONS RESORT AT VAIL ONE VAIL ROAD VAIL, CO 81657 8203.11 2017/08/02 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\ROOM 6103\8203.11EL105.DWG 08.02.17 10:39:19 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 ROOM 6103 LIGHTING PLAN EL-105 BAS MAS MAS 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® 08/25/17