Loading...
HomeMy WebLinkAboutB17-0293_M-000_1503670800.pdf' ' ISSUE LOG KEY: # DATE ISSUE LOG MECHANICAL SHEET INDEX TITLE MECHANICAL COVER SHEET M-000 PERMI T SET 07.25.2017 ISSUED AS PART OF A SET ' ' NOT PART OF SET ' ' ISSUED FOR INFORMATION ONLY * √ √ √ √ ROOM 6103 MECHANICAL PLAN M-101 ROOM 6103 MECHANICAL DEMO PLAN M-102 NOTES 1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS ON LEGEND SHEET ARE NOT NECESSARILY USED ON THIS PROJECT. 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND NOTATION CONVENTIONS OCCURRING IN THIS DRAWING SET ARE NECESSARILY DEFINED ON THESE LEGENDS. CONSULT THE ENGINEER IN THE EVENT SYMBOLOGY OR NOTATION INTERPRETATION IS REQUIRED. PLAN SYMBOLS POINT OF NEW CONNECTION POINT OF DISCONNECTION THERMOSTAT T PIPING DESIGNATIONS CHILLED WATER SUPPLY CHILLED WATER RETURN DOMESTIC WATER DOMESTIC HOT WATER DHW RECIRCULATION FIRE LINE PLUMBING VENT PIPE WASTE PIPE STORM DRAIN PIPE STORM DRAIN OVERFLOW HEATING WATER SUPPLY HEATING WATER RETURN DRAIN PIPE PLUMBING PIPING CHR CHS HWR HWS D CW HW HWC ST V W ST(OF) F HYDRONIC PIPING MECHANICAL LEGEND ABOVE SEA LEVEL PROJECT ALTITUDE 8020' FAN COIL SCHEDULE (HYDRONIC) MARK SERVICE TYPE FAN COOLING COIL HEATING COIL FILTER MANUFACTURER* & MODEL # ACCESSORIES REMARKS CFM ELECTRICAL AIR CONDITIONS WATER CONDITIONS AIR CONDITIONS WATER CONDITIONS @ ALT (IN WC) HP VOLT/ PH E.A.T. DB/WB (°F) L.A.T. DB/WB (°F) TOTAL MBH SENSIBLE MBH E.W.T. (°F) L.W.T. (°F) GPM MAX.WTR P.D. (FT.) E.A.T. DB (°F) L.A.T. DB (°F) SENSIBLE MBH E.W.T. (°F) L.W.T. (°F) GPM MAX.WTR P.D. (FT.) FC-1 BEDROOM HORIZONTAL CEILING 265 0.4 1/12 120/1 80/60 55/50 4.3 4.0 45.0 55 1.0 3.7 70 106 3.2 160 140 0.6 0.6 MERV8 IEC CPY04 - A, B, C, D MANUFACTURERS: * CARRIER, ENVIROTEC, MCQUAY, TRANE GENERAL NOTES: A: PROVIDE UNIT WITH REAR RETURN AIR. B: PROVIDE HONEYWELL THERMOSTAT TO MATCH EXISTING IN UNIT. THERMOSTAT SHALL HAVE 7-DAY PROGRAMMING CAPABILITY, TEMPERATURE ADJUSTMENT, AND MANUAL FAN OVERRIDE. C: PROVIDE DRAIN PAN FLOAT SWITCH IN LIEU OF SECONDARY DRAIN PAN D: PROVIDE 3-SPEED FAN THAT RUNS ON MEDIUM SPEED WHILE COOLING AND LOW SPEED WHILE HEATING DURING NORMAL OPERATION. TYPICAL HANGER DIAGRAM NO SCALE ANCHOR, REFER TO STRUCTURAL. THREADED ROD. HANGER. PIPE. CONCRETE STRUCTURE. NOTE: ALL PIPING WITH INSULATION TO HAVE INSULATION RUN FULL SIZE THROUGH HANGER WITH SHIELD AND INSERT. OFF DIAGRAM 45° DUCT TAKE- 45° NO SCALE W H 1/4 OF "W" OR 6" MINIMUM. END BEARING. SINGLE BLADE DAMPER IF H<8" OPPOSED BLADE DAMPER IF H>=8" SEAL AIRTIGHT AROUND ENTIRE TAKE-OFF. FIRE DAMPER AND FIRE/SMOKE NO SCALE 1. 2. NOTES: DAMPER ASSEMBLY DIAGRAM FAN COIL UNIT INSTALLATION NO SCALE D SA FAN COIL UNIT D FILTER W/ ACCESS PANEL. CONDENSATE DRAIN. PIPE INDIRECT TO APPROVED RECEPTOR (PROVIDE MIN. 2" DEEP TRAP). SHEET METAL DRAIN PAN. 3/4" SECONDARY DRAIN TO APPROVED RECEPTOR. PIPE INDIRECT TO FLOOR DRAIN ON SINK TAIL PIECE, TYP. ROUND HANGER ROD TYP. WITH EXCEPTION OF FAN COILS LOCATED IN ATTIC. SPRING VIBRATION ISOLATORS, TYP. DOUBLE LOCKNUT. CEILING 2-WAY COIL PIPING DIAGRAM NO SCALE E STRAINER WITH BLOWDOWN AND CAP. MANUAL AIR VENT AT HIGHEST POINT IN PIPING. RETURN SUPPLY MECHANICAL SPECIFICATIONS M-001 √ D C A B ISOLATION VALVE BALANCE VALVE PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: As indicated FOUR SEASONS RESORT AT VAIL ONE VAIL ROAD VAIL, CO 81657 8203.11 JAC ARK 2017/08/02 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL BDS S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\ROOM 6103\8203.11M000.DWG 08.01.17 1:24:19 PM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. xxxx.xx Copyright 2017 MECHANICAL COVER SHEET M-000 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® 08/25/17