Loading...
HomeMy WebLinkAboutB17-0293_M102_1507139640.pdfMASTER BEDROOM BEDROOM 2 LAUNDRY KITCHEN BEDROOM 3 BEDROOM 4 ENTRY TV INSTALL SHOWER SET PER INTERIOR DESIGN DRAWINGS. SHOWER TO REMAIN A STEAM SHOWER. REUSE EXISTING PLUMBING. INSTALL BATHTUB AND TUB CONTROLS PER INTERIOR DESIGN DRAWINGS. (E) 6"Ø (E) 26x10 (E) 24x8 (E) FCU (E)4"W (E) 8x6 (E) 18x10 INSTALL WATER CLOSET AND SEAT PER INTERIOR DESIGN DRAWINGS. INSTALL SINK BASIN AND FAUCET PER INTERIOR DESIGN DRAWINGS. INSTALL SINK, FAUCET, AND DISHWASHER PER INTERIOR DESIGN DRAWINGS. REUSE EXISTING PLUMBING. APPLIANCES BY OTHERS. INSTALL WATER CLOSET PER INTERIOR DESIGN DRAWINGS. REUSE EXISTING PLUMBING. (TYP. 2) INSTALL WATER CLOSET PER INTERIOR DESIGN DRAWINGS. REUSE EXISTING PLUMBING. INSTALL SHOWER SET: PER INTERIOR DESIGN DRAWINGS. REUSE EXISTING PLUMBING. (TYP. 2) INSTALL SINK BASIN AND FAUCET PER INTERIOR DESIGN DRAWINGS. REUSE EXISTING PLUMBING. (TYP. 2) INSTALL NEW 4"W, 3"V, 1-1/2"HW, AND 1-1/2"CW RISERS IN CONDO UNIT ONLY. CAP RISERS AT FLOOR AND CEILING. FCU-1 INSTALL MASTER TUB AND MASTER TUB FILLER PER INTERIOR DESIGN DRAWINGS. REUSE EXISTING PLUMBING. INSTALL SINK BASIN AND FAUCET PER INTERIOR DESIGN DRAWINGS. RECONNECT EXISTING PLUMBING. (TYP. 2) LINEAR OPENING IN CEILING TO RETURN PLENUM PER FOUR SEASONS STANDARDS. INSTALL TITUS 272RL SUPPLY GRILLE WITH WHITE FINISH AND TWO-WAY DEFLECTORS AT SOFFIT. 250 14X6 ROUTE FCU-1 CONDENSATE DRAIN TO SECONDARY DRAIN IN BATHROOM LAVATORY. INSTALL ACCESS PANEL IN CEILING BELOW FAN COIL UNIT. COORDINATE ACCESS PANEL LOCATION WITH GC. 4"W CONNECT 1" CW AND 1" HW TO (E) RISER IN ADJACENT TOILET ROOM AND ROUTE TO NEW PLUMBING FIXTURES. RECONNECT EXISTING DUCTWORK TO NEW HOOD. HOOD SELECTION PER INTERIOR DESIGN DRAWINGS. ROUTE 1/2" COPPER CW TO COFFEE MAKER, OVER, AND FRIDGE. INSTALL SHUTOFF VALVE AND BACKFLOW PREVENTER (WATTS SD-2 OR SIMILAR) PRIOR TO CONNECTION. APPLIANCES BY OTHERS. 1. DASHED LINES INDICATE PIPING ON FLOOR BELOW. 2. COORDINATE ALL CUTTING AND PATCHING OF WALLS AND CEILINGS WITH GC. 3. REFER TO DIAGRAM D, SHEET M-000 FOR FAN COIL UNIT INSTALLATION DETAIL. NOTES: T CONNECT (N) 4"W TO (E) RISER ON FLOOR BELOW IN ADJACENT TOILET ROOM AND ROUTE TO NEW PLUMBING FIXTURES. CAP (E)4"W (E) HWR (E) HWS (E) CHR (E) CHS (E) D INSTALL 6x6 TITUS 272RL EXHAUST GRILLE WITH WHITE FINISH AND TWO-WAY DEFLECTORS. PROVIDE INTEGRAL BALANCING DAMPER. BALANCE TO 50 CFM. REBALANCE (E) DIFFUSER TO MATCH EXISTING AIRFLOW. LOWER SPEED OF FAN COIL TO MATCH NEW AIRFLOW REQUIREMENTS. REBALANCE COOLING COIL TO 1.7 GPM AND HEATING COIL TO 0.9 GPM. (TYP. 4) (E) ST, (E) ST(OF), (E) V DN (E)V (E) ST (E) ST(OF) 3"V PIPING AND DUCTWORK SHOWN DIAGRAMMATICALLY. ROUTE ALL NEW PIPING AND DUCTWORK IN BATHROOM CEILING. SCALE: 1 ROOM 6103 MECHANICLA PLAN 1/4" = 1'-0" 4" W 1-1/2" V 3" V 2" W SHWR WCO LAV WC EXISTING WASTE RISER EXISTING VENT RISER SCALE: 3 WASTE & VENT PIPING DIAGRAM N/A EXISTING DOMESTIC WATER RISERS SCALE: 2 DOMESTIC WATER PIPING DIAGRAM N/A 1" CW 1" HW 3/4" CW 3/4" HW SHWR LAV WC 1/2" HW 1/2" CW 1/2" CW 1-1/2" V 2" V 1-1/2" W 4" W 3" W (E) 12x8 (E) 14x8 REFER TO DOMESTIC WATER PIPING DIAGRAM FOR CONTINUATION (E) HWS/R, (E) CWS/R, (E) D DN 12x8 INSTALL (2) 4' TITUS FL-10 JETTHROW DIFFUSERS WITH TITUS FBP-10 PLENUM. BALANCE TO 250 CFM PER SLOT DIFFUSER. PROVIDE (2) 4' TITUS FL-10 JETTHROW DIFFUSERS WITH TITUS FBP-10 PLENUM. LEAVE OPEN FOR RETURN PLENUM SPACE. 1 1 1 12x8 PROVIDE SIDE HEAD SPRINKLERS WITHIN COVE OF COFFER WALL IN LIVING ROOM. RELOCATE (E) FIRE PIPING ABOVE CEILING PLENUM. (E)CHS (E)CHR (E)HWS (E)HWR (E) 10x8 1/2" CHS/CHR, 1/2" HWS/HWR 2 5"Ø 5"Ø (TYP. 4) PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: As indicated FOUR SEASONS RESORT AT VAIL ONE VAIL ROAD VAIL, CO 81657 8203.11 2017/09/05 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\ROOM 6103\8203.11M102.DWG 09.21.17 9:40:13 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 ROOM 6103 MECHANICAL PLAN M-102 BDS ARK JAC 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® 10/04/17