HomeMy WebLinkAboutB17-0340_A-000-1_1507837260.pdf 056.0 OF b
1 2 3 4 5 6
zrri.„,
GENERAL STANDARD ABBREVIATIONS ARCHITECTURAL SYMBOLS #
'''
1. IF DISCREPANCIES OCCUR BETWEEN DRAWINGS OR BETWEEN THE SIM SIM 6
NOTE: FOR ADDITIONAL ABBREVATIONS; REFER TO SPECIFICATION 01 4200 FOR BUILDING SECTION # #
DRAWINGS AND THE SPECIFICATIONS, SUBMIT AN RFI FOR COMPLETE INDUSTRY STANDARD ABBREVIATION LIST REFERENCE X-### X-### 11170J
RESOLUTION.
2. DO NOT SCALE THE DRAWINGS.WRITTEN DIMENSIONS GOVERN. 10/12/17
DETAILS SHOWN CLOSER TO ACTUAL SCALE GOVERN OVER LARGER A
SCALE DETAILS. IF CRITICAL DIMENSIONS DO NOT APPEAR ON ACT ACOUSTICAL CEILING TILE # SIM I
CONSTRUCTION DOCUMENTS, NOTIFY THE ARCHITECT IN WRITING ADD ADDENDUM WALL SECTION
FOR RESOLUTION. SUBMIT AN RFI IF CRITICAL DIMENSIONS DO NOT AFF ABOVE FINISHED FLOOR REFERENCE X-###
APPEAR ON THE DRAWINGS. ALT ALTERNATE
3. THE BUILDING EXTERIOR IS DEFINED BASED ON A SYSTEMS
METHODOLOGY. REFER TO A-700 DRAWING SERIES FOR ALUM ALUMINUM Ia. .
COMPONENTS THAT COMPRISE EACH SYSTEM. ANOD ANODIZED III
4. PROVIDE ISOLATION BETWEEN ALL DISSIMILAR METALS WHERE THEY APPROX APPROXIMATE(LY) DETAIL ELEVATION # I.
OCCUR TO PREVENT ELECTROLYTIC REACTION AND CORROSION. ARCH ARCHITECT or ARCHITECTURAL REFERENCE X-### WI
I
■
5. VERIFY EQUIPMENT ROUGH-IN DIMENSIONS WITH MANUFACTURER ASI ARCHITECTS SUPPLEMENTAL INSTRUCTIONS
FOR EQUIPMENT THAT IS EXISTING, REUSED, OR FURNISHED BY 11 . 11
E OWNER. AUX AUXILIARY # E
6. ALL PLAN DIMENSIONS LOCATING DOOR ASSEMBLIES IN INTERIOR INTERIOR ELEVATION # .
GYPSUM BOARD PARTITIONING ARE TO EDGE OF DOOR, UNLESS B REFERENCE �#I X-111111 I#) IIIII
■ U
NOTED OTHERWISE. BLDG BUILDING
7. ALL PLAN DIMENSIONS LOCATING DOOR ASSEMBLIES IN INTERIOR BSMT BASEMENT III i
. WI
GYPSUM BOARD PARTITIONING ARE TO EDGE OF DOOR, UNLESS 1 Ref
NOTED OTHERWISE. BTWN BETWEEN
Z) m
8. ANY FINISH INDICATED FOR A PARTICULAR INTERIOR WALL MEANS r ct
EXTERIOR ELEVATION 1 X-### 1
THAT THE ENTIRE UNINTERRUPTED LENGTH OF THE WALL IS TO BE C REFERENCE I`� A = /-
FINISHED AS INDICATED UNLESS SHOWN OR NOTED OTHERWISE. CD CONSTRUCTION DOCUMENTS or CONTRACT DOCUMENTS
9. THE PRESENCE OF THE ARCHITECT OR AN ARCHITECT'S CJ CONSTRUCTION JOINT or CONTROL JOINT 1 Ref
REPRESENTATIVE ON THE JOB SITE DOES NOT IMPLY CONCURRENCE `/
OR APPROVAL OF THE WORK. THE CONTRACTOR SHALL CALL CLG CEILINGn.-- ■ ——
SPECIFIC ITEMS TO THE ATTENTION OF THE ARCHITECT IF THE CLR CLEAR # TYP. �� ���
CONTRACTOR WISHES TO OBTAIN THE ARCHITECT'S APPROVAL. CMU CONCRETE MASONRY UNIT DETAIL CALLOUT K^ I T T
CONC CONCRETE -### I I
CORR CORRIDOR
J
DEFINITIONS 2901 Blake Street, Suite 100
D � 8'-2" �f Denver Denver, CO 80205
ALIGN TO ACCURATELY LOCATE FACE BASED ON ADJACENT ITEMS OR DBL DOUBLE DIMENSION LINE 303.861.8555
CONSTRUCTION
DEMO DEMOLISH or DEMOLITION
Consultant
MAXIMUM THE CONDITION MAY NOT VARY TO A DIMENSION GREATER THAN THAT DF DRINKING FOUNTAIN
SHOWN WITHOUT THE APPROVAL OF THE ARCHITECT DIA DIAMETER CENTERLINE — — —
DIM DIMENSION or DIMENSIONAL
MINIMUM THE CONDITION MAY NOT VARY TO A DIMENSION SMALLER THAN THAT OW DISHWASHER
SHOWN WITHOUT THE APPROVAL OF THE ARCHITECT DWG DRAWING GRID LABEL- NEW — — —
TYPICAL THE CONDITION APPLIES TO SAME CONDITIONS THROUGHOUT UNLESS
NOTED OTHERWISE E
EA EACH GRID LABEL- EXISTING — — —
SIMILAR THE CONDITION IS THE SAME OR REPRESENTATIVE FOR ALL SIMILAR EJ EXPANSION JOINT
CONDITIONS, UNLESS NOTED OTHERWISE.ACTUAL CONDITIONS MAY ELEC ELECTRIC(AL)
VARY, BUT DO NOT REVOKE THE INTENT OF THE CONFIGURATION ELEV ELEVATOR ELEVATION LABEL
INDICATED. DETAILS ARE USUALLY KEYED AND NOTED "SIMILAR" ONLY
ONCE WITH THE FIRST OCCURRENCE AND ARE REPRESENTATIVE FOR EMER EMERGENCY
ALL SIMILAR CONDITIONS THROUGHOUT, UNLESS NOTED OTHERWISE. EOS EDGE OF SLAB EXTERIOR SYSTEM TAG pWS_MET2A
D EQ EQUAL D
EQUIP EQUIPMENT INTERIOR X#X
EWC ELECTRIC WATER COOLER PARTITION TYPE
EXIST EXISTING —TAG /\
WINDOW TAG W#
F ____-- -
FD FLOOR DRAIN CURTAIN WALL TAG C# _ -- •
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER STOREFRONT TAG S# r
FEC FIRE EXTINGUISHER CABINET --___ /1---; f.,-N\
��
FFE FURNITURE, FIXTURES AND EQUIPMENT SPOT ELEVATION --100'-0" / :c•---Cbt
FHC FIRE HOSE CABINET
If +TT O
DOOR TAG (####X) 0 MICHAEL
GNEVIN
GA GAUGE *
GALV GALVANIZED ROOM TAG ROO#NAME •{� 202985 A.
H AREA TAG AREA NAME % %AVD
ARCA'
HB HOSE BIBB 150 SF
H HORIZONTAL
HTT HEIGHT
CEILING HEIGHT ( 1' 0�
11(
HVAC HEATING,VENTILATION and AIR CONDITIONING TAG
FINISH TAG < XX# > Issuance
I
IBC INTERNATIONAL BUILDING CODE VIEW REFERENCE # / x-### PERMIT 06/30/17
J
JAN JANITOR KEYNOTE AND LEADER-
TYPE 1
JT JOINT Revisions Date
L KEYNOTE AND LEADER- 07 2700- SHEET
L ANGLE TYPE 2 WATERPROOFING
C M OSSOA
C
MAX MAXIMUM REVISION CLOUD
AND TAG
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL and PLUMBING
MEZZ MEZZANINE NORTH
MIN MINIMUM
MISC MISCELLANEOUS NORTH ARROW -S-
MO MASONRY OPENING
N
NA NOT APPLICABLE GRAPHIC SCALE
NIC NOT IN CONTRACT
NRC NOISE REDUCTION COEFFICIENT SCALE: 1/4" = 1'-0"
NTS NOT TO SCALE
0' 2' 4' 8' 16'
o Project Information
DETAIL NUMBERING
OC ON-CENTER BATTLESHIP GRID ORDER
OPNG OPENING
OPP OPPOSITE
E
P
PERIM PERIMETER C
PR PAIR or PROPOSAL REQUEST
PSF POUNDS PER SQUARE FOOT HATCHED DETAIL
PSI POUNDS PER SQUARE INCH LOCATION WOULD BE Ce N-
PT PAINT(ED), POST-TENSIONED SLAB or PRESSURE TREATED NUMBERED "A2" ON UJ 1-0
B THE DETAIL SHEET CO
Q I
z CO
QTY QUANTITY r
A LU 0
R
R RADIUS, RISER or THERMAL RESISTANCE 1 2 l 3 4 5 6 0 v U
B RCP REFLECTED CEILING PLAN B J Z CD
RD ROAD or ROOF DRAIN < J >
RE REFER TO or REFERENCE Im
REV REVISE, REVISED or REVISION <
RM ROOM Q Z CD
RO ROUGH OPENING LU
ROW RIGHT-OF-WAY W ♦^
RTU ROOFTOP UNIT V z -0
CO
S D
SAN SANITARY
SF SQUARE FOOT(FEET) LU H N
0)
SHT SHEET J CO (3
SIM SIMILAR J < I.
SPEC SPECIFICATION(S) < W Q
SQ SQUARE
STC SOUND TRANSMISSION CLASS > LL
STL STEEL J CO
STOR STORAGE
0
T < CO
TO TOP OF >
TOC TOP OF CONCRETE
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
Sheet Information
V
A VIF VERIFY IN FIELD A Sheet Title:
w ABBREVIATIONS &
WI WITH SYMBOLS
W/O WITHOUT
WD WOOD
WP WORKING POINT
WT WEIGHT Sheet Number:
2 A. 000 - 1a
0
„5a
a
s
M DPA Project: 15924.00
za
COPYRIGHT 2017-DAVIS PARTNERSHIP,
1 1 2 1 3 1 4 1 5 6