Loading...
HomeMy WebLinkAboutB17-0340_A-101C-1_1507837266.pdfSTORAGE 101 101 EXISTING BOLLARD, TYP C5 A-310-1 TYP C3 A-310-1 C4 A-310-1 A-510-1 C2 A-510-1 C2 OPP HAND CONTINUOUS WHEEL STOP FROM BUILDING TO BUILDING; ALIGN WITH EDGE OF CANOPY ABOVE STORAGE 101 4' - 0" 8' - 0" GC TO COORD LOCATION WITH EXISTING CONDITIONS 29' - 8" GC TO COORD LOCATION WITH EXISTING CONDITIONS 16' - 4" LEGEND EXISTING TO REMAIN NEW WALL EXISTING TO BE REMOVED REGION INDICATES AREA NOT IN SCOPE KEYNOTE LEGEND KEY PLAN GENERAL NOTES EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL SHUT DOWNS OR MODIFICATIONS WILL BE AT NIGHT OR ON WEEKENDS. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. PATCH AND REFINISH AREAS INPACTED BY CONSTRUCTION. FINAL CONDITION TO BE LIKE-NEW. ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE SALVAGE ALL MEDICAL EQUIPMENT, CONFIRM NEW LOCATION WITH OWNER PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. THEY SHALL BE SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH FROM THE SURFACE OF THE WALL. AT WALL MODIFICATIONS IN AREA A, GC TO FIELD VERIFY CONDITIONS AND PROVIDE SURVEY TO OWNER AND ARCHITECT SUMMARIZING PROPOSED MODIFICATIONS. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 4:46:30 PM 15924.00 A-101C-1 ENLARGED ANNOTATION AND DIMENSION FLOOR PLAN - AREA C 2017 06/30/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/4" = 1'-0" C2 ENLARGED ANNOTATION PLAN LEVEL 1 - AREA C - AMBULANCE BARN 1/4" = 1'-0" A2 ENLARGED DIMENSION PLAN LEVEL 1 - AREA C - AMBULANCE BARN NORTH NORTH A B C D 10/12/17