Loading...
HomeMy WebLinkAboutB17-0340_A-107-1_1507837268.pdfREF. REF. REF. FD FD H H H H A-101D-1 A1 R-02 R-03 TYP TYP R-03R-03 A-720-1 B2 R-04 R-05 ALL ROOF PENETRATIONS TO BE PROVIDED COMPLIANT WITH SYSTEM SPECIFIC MANUFACTURER RECOMMENDED DETAILS WHERE AVAILABLE. GC TO PROVIDE LETTER FROM A CERTIFIED THIRD PARTY ENTITY CONFIRMING SYSTEM INTEGRITY WILL BE MAINTAINED. 1. 2. 3. ANY ROOF MODIFICATIONS REQUIRE OWNER APPROVAL PRIOR TO DEMOLITION OR CONSTRUCTION. GENERAL NOTES KEY PLAN LEGEND REGION INDICATES AREA NOT IN SCOPE ALL EXTERIOR DETAILS PROVIDED BY THE ARCHITECT ARE INTENDED TO SHOW SYSTEM INTENT AND ARE TO BE REVIEWED AND CONFIRMED WITH MANUFACTURER WHERE KNOWN FOR SYSTEM COMPLIANCE PRIOR TO MODIFICATIONS. KEYNOTE LEGEND SET BOLT IN SEALANT GASKET SHEET METAL COVER EPDM CURB FLASHING EXISTING ROOF SYSTEM 8" EPDM ROOF MEMBRANE METAL HOOD CONDUIT FLASHING 3" EXISTING ASPHALT SHINGLE ROOF SYSTEM EXISTING 1/2" SHEATHING EXISTING WOOD FRAMING EXISTING WOOD FRAMING; PROVIDE ADDITIONAL FRAMING AT OPENING TO SUPPORT PENETRATION AND EXISTING ROOF ASSEMBLY GALV FASTENER; SEALED GALV FLASHING GALV COUNTERFLASHING ADHESIVE SEALANT SEALANT ADHESIVE DUCTWORK; SEE MECHANICAL CLEAT; 12" ON CENTER, MAX TOP AND SIDES GALV FASTENER; SEALED 6" MI N6" MIN HEM EDGE NOTE: PROVIDE STRAPS INSIDE SECTION TO THE STRUCTURAL FRAME FOR ADDITIONAL SUPPORT NOTE: PROVIDE UNDERLAYMENT OVER THE SUBSTRATE, UNDER ALL METAL FLASHING. CONTINUE VERTICALLY ON DUCT PENETRATION. NOTE: PROVIDE ADDITIONAL UNDERLAYMENT OVER THE METAL EDGES TO PROVIDE ADDITIONAL PROTECTION FROM WATER INFILTRATION SEE "SMACNA ARCHITECTURAL SHEET MANUAL", 2012 EDITION, FIGURE 8-12B FOR MORE INFORMATION. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 4:46:44 PM 15924.00 A-107-1 OVERALL FLOOR PLAN - ROOF 2017 06/30/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/16" = 1'-0" A1 OVERALL FLOOR PLAN - ROOF NORTH A B C D R-02 EXTEND WALKWAY PADS FROM EXISTING WALKWAY PAD SYSTEM TO EACH RELOCATED PIECE OF EQUIPMENT. PROVIDE WALKWAY PADS AROUND EACH PIECE OF EQUIPMENT. SEE MEP DRAWINGS FOR MORE INFORMATION R-03 PROVIDE EQUIPMENT SUPPORT ASSEMBLY COMPLIANT WITH EXISTING ROOFING MANUFACTURER AT RELOCATED EQUIPMENT LOCATIONS. SEE DETAILS ON THIS SHEET AND MEP DRAWINGS FOR MORE INFORMATION. R-04 PROVIDE ADJUSTABLE FRAMING SECURED TO CONCRETE DECK BELOW TO SUPPORT GAS PIPE LINE. FLASH INTO EXISTING ROOF AND SECURE AS REQUIRED. R-05 PROVIDE STEEL BRACKET SECURED TO SIDE OF BUILDING TO SUPPORT GAS PIPE LINE. 1 1/2" = 1'-0" E2 EQUIPMENT SUPPORT CURB 1 1/2" = 1'-0"E3 ROOF PIPE FLASHING 1 1/2" = 1'-0" E1 02 - 500 - EXTERIOR ROOF DETAIL AT ASPHALT SHINGLE DUCT PENETRATION 10/12/17