HomeMy WebLinkAboutB17-0340_A-151-1_1507837268.pdfH H 6e01 Ce78 Be78 3e78 4e78 5e78 6e78 7e78 9e78 12e78 13e78 14e78 15e78 18e78 21e78 De78 De79 A-151A-1 A2 A-151A-1 D4 EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN PATIENT AREAS ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS. WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL. GENERAL NOTES GENERAL NOTES AREA NOT IN SCOPE GYP. BOARD CEILING 2' x 2' ACT CEILING EPOXY FINISH ON GYP. BOARD CEILING EXISTING 2' x 2' ACT CEILING KEY PLAN KEYNOTE LEGEND MECHANICAL DIFFUSER (SUPPLY AIR) MECHANICAL DIFFUSER (RETURN AIR) 2' x 4' LIGHT 2' x 2' LIGHT RECESSED CAN LIGHT FIXTURE 8' x 0" CEILING HEIGHT ABOVE FINISH FLOOR 4' - 0" PENDANT LIGHT 18" x 18" ACCESS PANEL 2' - 0" WALL DECORATIVE LINEAR LIGHT 4' - 0" STRIP LIGHT CUBICLE CURTAIN TRACK NOTE: NOT ALL SYMBOLS SHOWN ON THE DRAWINGS ARE INDICATED BELOW. SEE MECHANICAL, ELECTRICAL FIRE ALARM, AND TECHNOLOGY DRAWINGS FOR ADDITIONAL SYMBOLS AND SYSTEMS INFORMATION SECURITY CAMERA EXISTING GYP. BOARD CEILING EXIT LIGHTING 2' x 2' ACT CEILING SCRUBBABLE GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH EXISTING CONDITION. GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL EQUIPMENT AHEAD OF DEMOLITION WORK. STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER. REMOVE AND REPLACE (E) CEILING RE: INTERIM LIFE SAFETY PLANS FOR MORE INFO. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 4:46:54 PM 15924.00 A-151-1 OVERALL REFLECTED CEILING PLAN - LEVEL 1 2017 06/30/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/16" = 1'-0" A1 OVERALL REFLECTED CEILING PLAN LEVEL 1 NORTH A B C D 10/12/17