Loading...
HomeMy WebLinkAboutB17-0340_A-200B-1_1507837273.pdfEE-06 EE-07 EE-07 EE-07 D5 A-511-1 A-200B-1 B1 A-200B-1 C1 EE-03 EE-02 A5 A-310-1 LEGEND EXISTING TO REMAIN NEW WALL EXISTING TO BE REMOVED REGION INDICATES AREA NOT IN SCOPE KEYNOTE LEGEND KEY PLAN GENERAL NOTES EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL SHUT DOWNS OR MODIFICATIONS WILL BE AT NIGHT OR ON WEEKENDS. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. PATCH AND REFINISH AREAS INPACTED BY CONSTRUCTION. FINAL CONDITION TO BE LIKE-NEW. ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE SALVAGE ALL MEDICAL EQUIPMENT, CONFIRM NEW LOCATION WITH OWNER PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. THEY SHALL BE SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH FROM THE SURFACE OF THE WALL. AT WALL MODIFICATIONS IN AREA A, GC TO FIELD VERIFY CONDITIONS AND PROVIDE SURVEY TO OWNER AND ARCHITECT SUMMARIZING PROPOSED MODIFICATIONS. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. R.O. 12' - 7 1/2" 8' - 9 1/4" HINGED BRACKET STEEL GATE PANEL, COLOR TO MATCH EXISTING CAMPUS STANDARDS 3' - 6" V.I.F 11' - 0" 3" 5' - 3" 5' - 3" 3" 11" 2' - 3" 4" STEEL GUARD RAIL, COLOR TO MATCH EXISTING CAMPUS STANDARDS CAST POST INTO CONCRETE, TYP. C2 A-200B-1 SIM 4" 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 4:47:09 PM 15924.00 A-200B-1 EXTERIOR ELEVATIONS AND PERSPECTIVES - FUEL TANK AND RAMP 2017 06/30/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/8" = 1'-0" D1 AREA B - NORTH ELEVATION 1/8" = 1'-0" D4 AREA B - WEST ELEVATION EE-02 CMU BLOCK WITH STONE CLADDING EE-03 STONE WALL CAP. EE-06 EXISTING BUILDING BEYOND EE-07 NEW GUARDRAIL A B C D A1 3D VIEW - EXTERIOR RAMP 1/2" = 1'-0" B1 ENLARGED ELEVATION - GATE ENCLOSURE 1/2" = 1'-0" C1 ENLARGED ELEVATION - GUARD RAIL, TYP. 1/2" = 1'-0" C2 SECTION DETAIL - GUARD RAIL SECTION 10/12/17