HomeMy WebLinkAboutB17-0340_A-720-1_1507837270.pdfINTERIOR PARTITION TYPES STRUCTURE A 7/8" HAT CHANNEL B 1 5/8" METAL STUD C 2 1/2" METAL STUD D 3 5/8" METAL STUD E 4" METAL STUD F 6" METAL STUD G 3 5/8" DOUBLE METAL STUD J 2 1/2" C-H METAL STUD K 4" C-H METAL STUD L 6" C-H METAL STUD M 2x4 WOOD STUD N 2x6 WOOD STUD P 4" CMU Q 6" CMU R 8" CMU S 12" CMU Z 1 1/2" "Z" FURRING CHANNEL D1s X EXAMPLE D = 3 5/8" METAL STUD 1 = 1 HOUR FIRE RESISTANCE RATING s = SOUND PARTITION FIRE RESISTANCE RATING* 0 NON-RATED 1 1 HOUR 2 2 HOUR 3 3 HOUR 4 4 HOUR SUB-TYPE a 6" ABOVE CEILING b UNDERSIDE OF STRUCTURE c UNDER SIDE OF CEILING f FURRING l LEAD LINED k SECURITY MESH p PARTIAL HEIGHT s SOUND PARTITION t THERMAL INSULATION v SOUND PARTITION WITH (2) LAYERS GYPSUM BOARD EACH SIDE w SOUND PARTITION WITH (2) LAYERS GYPSUM BOARD ONE SIDE (1) LAYER OTHER SIDE z TILE BACKER BOARD SMOKE RATED* X SMOKE PARTITION, SMOKE BARRIER OR WALL RESISTING THE PASSAGE OF SMOKE STRUCTURE FIRE RESISTANCE RATING SUB-TYPE SMOKE RATED (OPTIONAL) * SEE RATED PARTITION NOTE 2 GENERAL CONSTRUCTION AND LAYOUT NOTES 1. THE INTERIOR FRAMING SUBCONTRACTOR SHALL PROVIDE A DELEGATED ENGINEERED STUD DESIGN FOR ALL NON-STRUCTURAL METAL FRAMING FOR WALLS AND CEILINGS. SUBMIT FRAMING SHOP DRAWINGS WITH DETAILS, PRODUCT SELECTIONS, AND ENGINEERING CALCULATIONS STAMPED BY A LICENSED ENGINEER IN THE PROJECT JURISDICTION. ENGINEERING SHALL INCLUDE PROVISIONS FOR ELEMENTS ATTACHED TO/SUPPORTED BY THE FRAMING. FASTENER DESIGN AND SELECTION IS ALSO REQUIRED. SUBMIT ICC ES EVALUATION REPORTS FOR EACH FASTENER. USE OF DIMPLED OR PERFORMANCE ENHANCED SHAPED STUDS IS ACCEPTABLE. UNLESS OTHERWISE INDICATED DESIGN FOR A MAXIMUM DEFLECTION OF L/240 AT 5 PSF. AT PARTITIONS TO RECEIVE CERAMIC TILE DESIGN FOR A MAXIMUM DEFLECTION OF L/360 AT 5 PSF. REGARDLESS OF DESIGN, PROVIDE 20 GA STUD AT A MINIMUM. 2. ALL INTERIOR PARTITIONS ARE DIMENSIONED TO FINISHED FACE OF GYPSUM BOARD UNLESS NOTED OTHERWISE. 3. ALL STUDS SHALL BE FULL HEIGHT TO UNDERSIDE OF STRUCTURE UNLESS INDICATED OTHERWISE BY PARTITION TYPE. 4. BOTTOM OF GYPSUM BOARD SHALL BE 1/4” TO 3/8” ABOVE FINISH FLOOR UNLESS OTHERWISE INDICATED. 5. OFFSET STUDS AS NECESSARY TO ALIGN OUTSIDE FACES OF GYPSUM BOARD AT ADJACENT WALL TYPES WITH VARYING LAYERS OF GYPSUM BOARD. 6. PROVIDE DEEP LEG TRACKS (3" FLANGE) AT HEAD OF PARTITIONS AT ALL NON-LOAD BEARING PARTITIONS FOR EACH CONDITION THAT ALLOW FOR 1" OF UPWARD MOVEMENT AND 1" OF DOWNWARD DYNAMIC MOVEMENT CAPABILITIES. 7. AT SLAB-ON-GRADE CONDITIONS PROVIDE DYNAMIC MOVEMENT REQUIREMENTS CALLED FOR IN THE GEOTECHNICAL INVESTIGATION (SOILS REPORT). IF NO GEOTECHNICAL INVESTIGATION EXISTS CONTACT THE ARCHITECT FOR DEFLECTION CRITERIA. 8. ALL PARTITION TYPES MARKED BY A "t" SUFFIX (IE. D0t) SHALL BE INSTALLED WITH FULL HEIGHT AND WIDTH CONTINUOUS THERMAL INSULATION AND, IF INDICATED, CONTINUOUS VAPOR RETARDER. 9. PROVIDE GYPSUM BOARD CONTROL JOINTS PER ASTM C 840 UNLESS OTHERWISE INDICATED ON DRAWINGS. 10. PROVIDE FIRE BLOCKING AND DRAFT STOPS PER CODE. 11. AT LOCATIONS ADJACENT TO GLASS SYSTEMS, GC TO VERIFY IN FIELD AND PROVIDE FASTENERS SUCH THAT THE INSTALLATION OF METAL FRAMING DOES NOT ADVERSELY IMPACT THE GLASS SYSTEM. RATED PARTITION NOTES 1. FIRE RATED ASSEMBLY CRITERIA TAKE PRECEDENT OVER ANY OTHER CONSTRUCTION CRITERIA. 2. REFERENCE LIFE SAFETY DRAWINGS FOR LOCATIONS OF FIREWALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE PARTITIONS, SMOKE BARRIERS, AND WALLS RESISTING THE PASSAGE OF SMOKE. COMPLY WITH IBC AND ANY OTHER APPLICABLE CODES FOR CONSTRUCTION REQUIREMENTS FOR EACH RATED PARTITION TYPE. 3. REFERENCE SPECIFICATION SECTION 07 8413 –‘PENETRATION FIRESTOP’ FOR TREATMENT OF ANY PENETRATIONS THROUGH A FIRE RATED PARTITION. NEEDS TO MEET UL LISTED TEST REQUIREMENT. 4. REFERENCE SPECIFICATION SECTION 07 8443 –‘JOINT FIRESTOP’ FOR TREATMENT OF TOP AND BOTTOM OF WALL JOINTS AND JOINTS TO ABUTTING CONSTRUCTION. NEEDS TO MEET UL LISTED TEST REQUIREMENT. 5. PROVIDE AND SUBMIT FOR APPROVAL U.L. RATED HEAD OF WALL ASSEMBLIES FOR EACH RATED PARTITION CONDITION THAT ALLOWS FOR THE DYNAMIC MOVEMENT INDICATED. IF ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION (AHJ), OBTAIN ENGINEERING JUDGEMENTS FOR JOB SPECIFIC CONDITIONS NOT ADDRESSED BY TESTED ASSEMBLIES. 6. PROVIDE FIRE-RATED ACCESS DOORS AND FRAMES TO REACH DAMPERS OR CONTROL VALVES IN RATED PARTITIONS OR CEILING AS REQUIRED TO MAINTAIN RATING. PROVIDE NONRATED ACCESS DOORS AT NON RATED CONSTRUCTION. 7. WHERE DEVICES ARE RECESSED IN A FIRE RATED PARTITION PROVIDE: A.) DEVICE RATED FOR INSTALLATION IN RATED PARTITIONS, OR B.) CONSTRUCTION SUCH THAT FIRE RATING IS MAINTAINED BEHIND RECESSED DEVICE. 8. WHERE STRUCTURAL ITEMS SUCH AS HANGERS FOR STAIRS ARE EMBEDDED IN A RATED PARTITION CONSTRUCTION SHALL BE SUCH THAT FIRE RATING IS MAINTAINED BEHIND EMBEDDED ITEM. 9. MARKING AND IDENTIFICATION: FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE LABELED PER CODE. 10. PROVIDE SMOKE PARTITIONS TO LIMIT THE TRANSFER OF SMOKE. FILL JOINTS AND THE SPACE AROUND PENETRATING ITEMS SUCH AS DUCTS, PIPES, CONDUITS, AND SIMILAR BUILDING SERVICE EQUIPMENT WITH AN APPROVED MATERIAL TO LIMIT THE PASSAGE OF SMOKE. 11. SEE A-720.1 FOR TYPICAL FRAMING DETAILS. SOUND PARTITION NOTES 1. ALL PARTITION TYPES MARKED BY AN "s" SUFFIX (IE. D1s) SHALL BE INSTALLED AS A SOUND PARTITION INCLUDING: FULL HEIGHT AND WIDTH SOUND ATTENUATION BLANKETS (SAB), ACOUSTICAL JOINT SEALANT AT TOPS AND BOTTOMS OF ALL WALLS AND PENETRATIONS, DRYWALL TO BE FROM FLOOR TO DECK BOTH SIDES. 2. PROVIDE ELECTRICAL OUTLET BARRIER PADS IN SOUND PARTITIONS. 3. STAGGER DEVICES THAT PENETRATE OPPOSING WALL SURFACES IN ADJACENT STUD CAVITIES. RATED ASSEMBLY INFORMATION TOP OF WALL ASSEMBLY: • STANDARD INTERIOR NON-BEARING WALL ASSEMBLY: UL HW-D-0495 OR EQUAL • SHAFTWALL FLAT CONCRETE: UL HW-D-0496 • SHAFTWALL PARALLEL TO BEAM: UL HW-D-0497 • SHAFTWALL PAN DECK: UL HW-D-0504 • SHAFTWALL PROTECTED ROOF DECK: UL HW-D-0559 WALL ASSEMBLY: • STANDARD INTERIOR NON-BEARING WALL ASSEMBLY : UL U419 OR UL U423 • SHAFTWALL ASSEMBLY: UL U415 SILL TRACK OF WALL ASSEMBLY: • PROVIDE UL LISTED ASSEMBLY COMPLIANT WITH THE UL WALL ASSEMBLY AND THAT MATCHES FIRE RESISTIVITY OF THE WALL. D0b 4 7/8" 5/8" 3 5/8" 5/8" D0X 4 7/8" 5/8" 3 5/8" 5/8" D1b 4 7/8" 5/8" 3 5/8" 5/8" DOOR / FRAME MATERIAL: AL/G - ALUMINUM GLASS HM - HOLLOW METAL WD - WOOD PT - PAINTED STAIN - STAINED MFR - MANUFACTURER DOOR FINISH: PL# - PLASTIC LAMINATE ST - STAINED CA - CLEAR ANODIZED PT - PAINTED KF - KYNAR FINISH GL - GLASS DOOR NOTES 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS. 2. REFER TO SPECIFICATIONS FOR HARDWARE TYPES AND SCHEDULE. 3. ALL FIRE RATED DOORS SHALL HAVE UNDERWRITERS LABEL ON DOOR AND FRAME. 4. WHERE EXISTING DOORS TO REMAIN, TOUCH UP SCUFFING TO MAKE DOOR FINISH LIKE-NEW. 5. AT EXISTING DOORS IN SCOPE: WHERE SCUFFED,PATCH AND REFINISH TO LIKE-NEW CONDITION. IN AREA C, REFINISH EXISTING DAMAGED DOORS AND DOOR FRAMES. DOOR AND HARDWARE SCHEDULE - ABBREVIATIONS LEGEND/NOTES FRAME NOTES 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS PRIOR TO ORDERING OR FABRICATING ANY FRAMES. 2. ALL ELEVATIONS ARE DRAWN FACING THE EXTERIOR OF THE WINDOW FRAME. 3. STOREFRONT FABRICATOR TO PROVIDE REINFORCING AS REQUIRED 4. ALL DIMENSIONS ARE TO MASONRY OR ROUGH OPENING UNLESS NOTED OTHERWISE, PROVIDE PROPER SHIM CLEARANCE AS REQUIRED. 5. AT EXISTING FRAMES IN SCOPE: WHERE SCUFFED, PATCH AND REFINISH TO LIKE-NEW CONDITION GLAZING TYPES S = PROVIDE TEMPERED GLASS IN NON-RATED DOORS WHERE INDICATED. F = PROVIDE FIRE- PROTECTION-RATED GLASS MEETING OR EXCEEDING THE RATING OF THE DOOR ASSEMBLY WHERE INDICATED SEE SPECIFICATION FOR ACCEPTABLE GLASS TYPES. SINGLE FLUSH F1 RE: SCHEDULERE: SCHED. SINGLE NARROW LITE (TEMPERED OR FIRE RATED GLASS) N1 RE: SCHEDULE RE SCHED. 3' - 4" 8" 8" 8" DOUBLE FLUSH F3 RE: SCHEDULE RE: SCHEDULE EQ EQ SINGLE NARROW LITE (TEMPERED OR FIRE RATED GLASS) N2 RE: SCHED. EQ EQ 8" 3' - 4" 8" 8" 8" 8" RE: SCHEDULE UNO 6" TYP. TYPE RE: PARTITION SECTION 09 2900 - GYPSUM BOARD 08 1416 - FLUSH WOOD DOOR 08 1113 - INTERIOR HOLLOW-METAL FRAME 05 4000 - COLD-FORMED METAL FRAMING 07 9200 - JOINT SEALANT07 9200 - JOINT SEALANT TYPE RE: PARTITION SECTION 09 2900 - GYPSUM BOARD 08 1113 - INTERIOR HOLLOW-METAL FRAME 08 1416 - FLUSH WOOD DOOR 07 9200 - JOINT SEALANT 05 4000 - COLD-FORMED METAL FRAMING SINGLE OR DOUBLE DOOR FRAME HM1 RE: SCHEDULE 2" 2" RE: SCHED. 2" / C2A-720-1 /C1 A-720-1 2 1/2" 4" 1 1/2" MIN MECH SEE 1 1/2" MIN 4 1/4" MECH SEE WALL BUMPER SECURED TO VISUALLY CONCEALED METAL FRAMING 16 GA GALV BRAKE METAL; EASE EDGES COUNTERSUNK FASTENER, TYP 24" OC MAX SNOW MELT PIPE AND PIPE CLAMP; SEE MECHANICAL FOR MORE INFORMATION EXISTING WALL EXISTING DOOR 8" EXISTING DOOR SWING COORD WITH EXISTING FLOOR 7' - 2" EXISTING CEILING; CUT BACK PANELS TO PREVENT PIPE FROM DAMAGING CEILING PANEL, PROVIDE FLANGE, AND SEAL THE OPENING CONCRETE HOUSEKEEPING PAD B1 A-720-1 SIM FLOORING TO MATCH EXISTING HEAT WELD ALL SEAMS, TYP BOTH SIDES EXISTING FLOORING OVER EXISTING CONCRETE SLAB ON GRADE STEGO 'CRETECLAW' TAPE OR SIM STEGO 'WRAP' 25 MIL VAPOR BARRIER NEW ELEC DUCT; SEAL ALL JOINTS; SEE ELECTRICAL NEW CONCRETE INFILL AT TRENCH; FORM FOR DUCT INSTALLATION 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 4:47:33 PM 15924.00 A-720-1 DOOR SCHEDULE, PARTITION TYPES, AND DETAILS 2017 06/30/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 DOOR SCHEDULE ROOM LEAF FRAME Hardware Set Fire Rating Wall Widt h Remarks REV NAME Door Type Door Material Finish Width Height Thickness Door Glass Type Frame Type Frame Material Frame Finish LEVEL 1 101 STORAGE F3 WD PT 6' - 0" 7' - 0" 1 3/4" - HM01 HM PT 23 - 5 1/4" 110X (E) CORRIDOR N1 WD PT 4' - 0" 7' - 0" 1 3/4" - PT 1 20 4 7/8" RESISTS PASSAGE OF SMOKE 120X (E) CORRIDOR N2 PT 7' - 0" 7' - 0" 1 3/4" F HM 22 PER LS101-1 4 7/8" REUSE EXISTING FRAME. REFINISH FRAME. RECERTIFY ASSEMBLY. 1200A EQUIPMENT F1 WD PT 3' - 6" 7' - 0" 1 3/4" - HM01 HM PT 21 PER LS101-1 4 7/8" PARTITION TYPES SCHEDULE PARTITION TYPE USE DESCRIPTION PARTITION WIDTH STRUCTURE CONSTRUCTION DESCRIPTION TOP OF WALL TO FIRE RATING DESIGN NUMBER (FIRE) D0b PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A D0s PARTITION WALL, SOUND BATTS 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A D0X SMOKE PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A D1b 1-HR PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE 1 HR UL U419 W1 1/4" = 1'-0" DOOR TYPES 3" = 1'-0" C1 HM INTERIOR DOOR FRAME JAMB 3" = 1'-0" C2 HM INTERIOR DOOR FRAME HEAD 1/4" = 1'-0" FRAME TYPES <02 - 600 - FINISH SCHEDULE> Room Number Room Name Floor Finish Base Finish Wall Finish Casework Ceiling Finish Remarks N E S W LEVEL 1 FUEL TANK ENCLOSURE SEE A101B-1 AND A200B-1 FOR SPECIFIC FINISH INFORMATION 101 STORAGE EXISTING FINISHES TO REMAIN. EXTEND EXISTING FINISHES TO NEW INFILL WALL. 102 O2 ENCLOSURE 110 (E) CORRIDOR EXISTING FINISHES TO REMAIN. PROVIDE MATCHING FINISHES AT CEILING, WALLS, AND DOORS TO EXISTING FACILITY AT THIS LOCATION. 120 (E) CORRIDOR EXISTING FINISHES TO REMAIN. PROVIDE MATCHING FINISHES AT CEILING, WALLS, AND DOORS TO EXISTING FACILITY AT THIS LOCATION. 1200B EQUIPMENT EXISTING EXISTING EXISTING PT EXISTING PT - MATCH BLDG STANDARD EXTEND EXISTING WALL BASE AESTHETIC TO NEW WALLS. WALL PAINT TO MATCH EXISTING ADJACENT FINISHES, BOTH SIDES OF WALL. 1 1/2" = 1'-0" B1 PIPE WRAP 1/2" = 1'-0" B2 PIPE WRAP ELEVATION 1 1/2" = 1'-0" A1 FLOOR TRENCH SECTION 10/12/17