Loading...
HomeMy WebLinkAboutB17-0340_C200_1507837260.pdf 1 2 3 4 5 6 X44 , SITE HORIZONTAL CONTROL NOTES: 1. ALL DIMENSIONS, CURVE DATA AND LINE DATA ARE AT FLOWLINE UNLESS OTHERWISE NOTED. 10/12/17 2. REFER TO PAVING SECTIONS THIS SHEET. 3. CONTRACTOR TO SUBMIT JOINT PATTERN FOR CONCRETE PAVEMENT, PRIOR TO CONSTRUCTION, FOR APPROVAL. SEE JOINT DETAILS IN PLANS. 4. REFER TO LANDSCAPE/ARCHITECT PLANS FOR FINAL IIIIIIIII III SIDEWALK HANDICAP RAMP LAYOUT AND DETAILS AND FOR u . WI LANDSCAPING REQUIREMENTS. E 5. THESE PLANS ARE BASED UPON THE ARCHITECTURAL E 11111111111 I �� BUILDING PLANS PREPARED BY DAVIS PARTNERSHIP, DATED j y 2017.04.26 AS PROVIDED DIGITALLY. ANY SUBSEQUENT MIMI �I REVISIONS TO BUILDING PLANS ARE NOT REFLECTED IN THIS PLAN SET. CONTRACTOR TO VERIFY AND COORDINATE DOOR III 111 ■ ■■ I LOCATIONS WITH ARCHITECTURAL PLANS PRIOR TO I /I U i CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCY. I. ■ I I 6. REFER TO ELECTRICAL PLANS FOR SITE LIGHTING POLE I ■ SS LOCATIONS. COORDINATE ANY DISCREPANCIES WITHDAV I S 14 a RE: ARCH AND LS. FOR I // ENGINEER PRIOR TO INSTALLATION OF POLE BASES. RAMP LAYOUT AND WALL PARTNERSHIP I. I INFORMATION I /� ����� ��,�� ��� ► ARCHITECTS ir ,- po--- ss �I� / N� ,_ -t_ti_ 1 , 2901 Blake Street, Suite 100 o I----; ss — em, ,��� 1 L_____ I i / /S/ 4r i ' Denver 303.861.8555Denver, CO 0205 ��dr�pN / IMP;il � I / 11 o ' - ----___ -� - - _ _ 6.00' I /acs I Consultant II► I .• �. 19.1 d �� — - - — _ — — a I / / I JOB NO.:M14.0440.004 I I ® / p � 4,011:4! r� I I ., . ., 0. a ;��� 1 20.1 , ��I /mon MARTIN/MARTIN 'ice,__ --Irl'-,I�I� . •••O .•� ��' .. .�� a —�� ° '� ���.,�,N r ��J , • . �1p I / �.,0,,�1.7 d• • CONSULTING ENGINEERS J� _._ti.„..,,, • �_i�/4.,& �- __ �. O dad I / �' .c�.�I aI -ii_ • , _a, � ° Q°d __— — Ii �E'/�`. �!,\` G 0101 FAWCETT ROAD,SUITE 260,AVON,COLORADO 81620 �_, � EDGE OF -- I // ♦C ° 970.926.6007 MARTINMARTIN.COM ♦♦ '—_ / \ . �� `�-� FUEL TANK ° �� / I — • • BEGIN RETAINING a a ° a •� / �` ! - ® a ® ■ CENTER OF // j /i.�` f — — — — - a �- // . ♦ — �' °. o• WALL EXTENTION -_=ems �I�j a , a —® TRANSFORMER PAD ♦ • N:11 AWING �� I 1 a i� N:11175.04 d RETAINING ��. �it�, II Od•• 9 E:7577.97 8.0 �►` E:7648.18 ir -la SW �� WALL. RE: _ 21.3 _ •v - I ARCH ��nn. �,�,��•��r. ,,,4 �■ STAIRS, 8 RISERS I Q‘4 r 1 ♦r I P#1 I PPZPOA It* - I ® ��������I A 04**�� -,0"...:4,1414% ' , , ����� ,****A44 , , !,4 4� _ �,�� o BEGIN WAL CONC. I �— ' ISI`?�������i�������i�i-� �I�� �:���I�I��I �►i - _ v �I� `r N:11173.07 1 ♦ ♦ ♦ ♦s ♦ NIM"Ill"li"ViVh r � OP*SSIN1441474$41- ! , � �--�st=� �, .�►,11,� 6.00 1,i a' _ - - j E:7662.58 - ��o- , FUEL TANKCENTER OFA 4$4411S4 J1s , `� TRANSFORMER ##, I - - - - T- - - T' ' , ♦ , ♦/�-� � 0 • CLEAR AREA FOR cfk*/.40• % t ,-, FUEL TANK , , ��, - T- I ♦ t' ` irt� � � � ENCLOSURE. bS��♦ e ♦ ri BACKFILLING � * ih, ��,�,�, _1172.59 - _ - ����, RE. ARCH. ��ttpfev44 _ _ _-E �a - - -E- - - -E- - I '41\4 �� � - E:7611 .65 - FCS - - - - -- � �� �wl � �1 . - - -I-E- o- ;I`3��`'�j�ev',�►�►,,�,�.1�,-. - - . 'go,i� ; REGjs ******#A#A1*****, ♦ ♦ ♦ ♦ ♦ ♦ ♦ �o: G•� ,.—w— _ _ - - _ _E - - - _ �j�j�j�j�j� %ci. . �:0•► ♦ ♦ ♦- _W- - _ - - _ _ — _ .. - - - _ _ —rage ," , , , , ♦ ♦ ♦4____ ♦ $ ;,' 32753 y: 1 W - - —W— —1 e — — — SS— _ , ♦ ♦ ; :JUNE 30, 2017: 1W UU — — — —W — — W ,� •� . �6 CONC. CURB HEAD ��`•'• •'�'/►� (1) — — — REPLACE PAVER AREA — — ��%����I , , , , CLASS B CONC. ==�� is/ SS REMOVED DURING TANK AND — ,� . �lVAL i -SS- - - - - _SS - - - I WALL PLACEMENT REPLACED CONC. CURB I -vv---42116161._ - �_, SS - - -I -SS - - HEAD REMOVED DURING I I - - -W- - - - - - - - - - - - - - LANDSCAPE CONTRACTOR SHALL VERIFY PROPERTY - -SS- - - TANK PLACEMENT I SS - - - - -ins_ _ _ - - AREA TOV. UNIT PAVER SS- - - I EXTENTS OF PAVER - - -W- - - 1 " SAND -\ 7 LINE BOUNDARY PRIOR TO - SS_ - - 111/1 CONSTRUCTION. FUEL TANK SHALL BE - -SS- - - - _ REPLACEMENT BASED ON LOCATED WITHIN THE WMC PROPERTY -SS- -_ � - _ I FUTURE PAVER EXTENTS SETTING BED Original Issuance Date BOUNDARY AN NOT WITHIN THE WEST - - - -SS- - --- L- T- - - - _ - SS- = z - , , ' , , PERMIT 06/30/2017 MEADOW DRIVE R.O.W. - -SS- - - - - APPROX. SS- - - - - -SS- - - - - o - g . . .. . . .. . . . FABRIC TV -------_-_-_17 -E- ---_---1: _ -1 BARRIER Revisions Date No. -TV - - - - -E-T- - - - STREET CUT FOR ELEC. LINE. LOCATION 2.00' TV - - - - -E_ _T_ - - _ - -TV - - T- - - ASPHALT PATCHBACK, PAN & CONC. PAN Et _ X . . . . . . . . . . .\ - -TAT - - - - -T- - - SIDEWALK REPLACEMENT, AND - TV -__-E- - -- -T- - - -_=-___- - --__E-_=___ _ _ w o - - COMPACTED I - -TV- - __E- - -- GURB AND GUTTER APPROX. LOCATION - E= - - 1 8 I - CDOT CLASS - TV - _ REPLACEMENT._T_ ` - - - SIDEWALK } 6 BASE TV- `1 __________ __________ __________ ___________ ________ _________ T_ _ - - T _ - - - 500 - _ _ : . . .. . . . 11- - T =__ COMPACTED SUBGRADE _ — COMPACTED C CDOT CLASS -4,, C 6 BASE I CONCRETE CURB HEAD AND PAVER AREA SECTION. N .T.S. RE: ARCH PLANS FOR ADDITIONAL Project Information INFORMATION TYPICAL SLAB ON GRADE „ CP REINFORCEMENT �1 8°~ 2-##4 AT 184 BOTTOM aQ j \\/ \7 / o FINISH GRADE 5 MIN. �1 ///\ j\�/////\\//\//,K/ Ir OR SLAB \\.; o REPLAN \\ / \//�\/O ti 1 LO Q \\%�♦� j\\� TYPICAL WALL CO ' REINFORCEMENT l' N- z MINIMUM \\/\/\ /\,/ AT CHEEK WALL CO o ♦j/♦\j/♦/ Z VI O o I ` � ill Z U T 3-#4 CONT. #4 BAR AT BOTTOM J B 8» EACH RISER B J Q CD z MIN. > a 1 '-8” Z Q BUILDING WALL (CONCRETE OR 0 W 0 z MASONRY) OR CHEEK WALL W 0 Q Lii NOTE: WHERE CHEEK WALL IS 'V "v' \ • O z REQUIRED PROVIDE 8" THICK \ \/ Z i CONCRETE WALL WITH \ \� BOTTOM BAR W #4 AT 10" EACH WAY Ur #4 DOWEL AT 10" O.C. W Q SECTION 3/4"x5" CONT. KEY I. H z z QF- TYP. CONCRETE STAIRS ON O O w GRADE >a Q z U W u_ o NOT TO SCALE M/M 2009 0 Co m UCO ciw Q O 4 () j n g 0_ CL ct Li 0; �; Sheet Information I— n Q 1, o Aa - A Sheet Title: NIIID0 o - SITE LAYOUT AND N N RECONSTRUCTION O ticHow �vnni s e [ tlnw, CAIt 0 [ idn[ role orc. _� pr PLAN - = CALL 811 2-BUSINESS DAYS IN ADVANCE Sheet Number: z BEFORE YOU DIG, GRADE OR EXCAVATE FOR o MARKING OF UNDERGROUND MEMBER UTILITIES D 1- ,..) MARTIN/MARTIN ASSUMES NO RESPONSIBILITY FOR UTILITY C200 0 . LOCATIONS. THE UTILITIES SHOWN ON THIS DRAWING HAVE BEEN LI] -1 11 PLOTTED FROM THE BEST AVAILABLE INFORMATION. IT IS, HOWEVER, o z 10 5 0 10 20 THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY THE SIZE, SCALE: l ''=10' MATERIAL, HORIZONTAL AND VERTICAL LOCATION OF ALL UTILITIES o cL ALL DIMENSIONS SHOWN ARE U.S. SURVEY FEET PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION. DPA Project: 15914.00.000 w o COPYRIGHT 2016 -DAVIS PARTNERSHIP,P.C. 1 2 3 4 5 1 6