Loading...
HomeMy WebLinkAboutB17-0340_C330_1507837260.pdf 1 2 3 14 15 6 1014 OF ' . . • 1111 \ \ `� : \ • -31• `� \\ = •\ a I I • / • /• / • \\ \ v I / • // • 10/12/17 \� FIRE HYDRANT RE: CDOT UTILITY PLANS // / \T • . I • / • • • • / • / AvA \ • \ • \\ \ I• / • / • o: - N \ �" •• I. / / VAV "o / %s'i I / \ N \il c ) / N • •• / • luau \ _ • \T \ h I / • N . \ h I / U• .■ - E v • �-. . . .4 .d I 12" GV RE: CDOT UTILITY PLANS • . . N . a a-\.. •.4� •\ • °• I7 .: • •// // • • E II . . ■ • \I / N • •a. I / . d C� / . • . • . . MEMO LI •000ThFRONT%GE . 1111111111111111'• a :::. I V. •d ° DAV I S A. ; • d av a \\ • LI c I1111111M11111111111111. • .• N 0\ I / / . SOuTH FfROVT%GE . a I\ IJ \a / / . • • • • , .1 0 . /-> ../c: • //. .. �E • . •�E 0. • '- . Ir. •1‘.• el PARTNERSHIP v d . :v \T I / Y . . / : . • . \\ • . • F / a .41,.\. .:. ... I F / ARCHITECTS I \\ I I \\ I . ... \ J, 2901 Blake Street, Suite 100 :TV \� X*\ �� \\ �� Denver Denver, CO 80205 ,ii \ \ // WFULLY RESTRAINEDI • _ I 5.98LF 12 DIP 303.861.8555 ° \ \ ;!��� Consultant \ // F •• , ` \ \ // Vii, \ JOB NO.:M14.0440.004 \ I \� T 2.50L\" DIP \ \� p6INSTALL INTERNALCONCRETE THRUST aiArogoi� CONFULLY REST\I\D L / CONNECT TOEX. MA_ THRUST RESTRAINT MIN. 0101FAWCETTROAD,SUITE260,AVON,COLORADO81620 7.81LF 6 DP \ ' 12"X6" TEE N:11442.71 \\ iti FULLY RESTRAINED i►= � Sir E:7864.35 � CONC. VOLUME 5 CY. N:11437.79 _v„,,.,11 .25° BENDE:7867.75RESTRAIN JOINTSIlk N:11431 .92 ,i, ... WITHIN 20' OF BEND -, �..:::::�� T,_ ■■■■■■■.. Ili■■■■■_. E:7859.27 ‘, s ■■■■■■■■=.. _ 45° VERT. BEND ■■■■■■■■m..� E- �1� \ :! .■■...11M�- E • ■■■■■■■■=■■. .■■■■■■■� 12" GV N:1 1430.70 �y :I:I:I:I:I:I:I::C' \ I .■■■■■■■�. D E:7857.90 \ ® I .I..... • 6" DIP WATER SERVICE `® ......, D CONNECT TO EX. MAIN 45° VERT. BEND '�, bbw- �" . ', ..... �" , N:11429.52 N:11426.58 •' \ • •' '4E:7883.45 E:7853.31 6„ GV - -IN- - _ �� �\ - -� CAP FOR FUTURE �'-!- tlitfritt" N:11436.37 E_12"X6" TEE ���' CONNECTION TO WATER / I�� SS E:7865.69 -'1i�- � N:11437.79 :1 1437.75 I - - E ENTRY ROOM 1 .83LF 6" DIP �' - _ N:11425.49 1I FULLY RESTRAINED RESTRAIN JOINTS E:7847.08 - 7.52LF 12" DIP ��i�p0 EG/ST= 6.17LF 6" DIP - - -WITHIN 20' OF BEND �����'"R"'' 4.75LF 6" DIP FULLY RESTRAINED ' FULLY RESTRAINED , . - - _ _ .I I FULLY RESTRAINED 1 1 .61 LF 12" DIP - - _ t O;4 • �`�j�\ ��� - FULLY RESTRAINED __ ,�(j. G ,��` 2.00LF 6" DIP • I - ` - _ �./ FULLY RESTRAINED ,�,aI it- _ 32753 I Erle mak--- I �E� � %•\!),..... ; JUNE 30, 2017; 1 • 45° BEND N/��_ r% _ �\ ,�� / 'i • • ivy N:11425.24 ir�il4, i, _ Nip,' . . _ _ •GNAL • �� ' / I �W •. \c� E:7851 .83 v ' v 4 'W I 4' • • • .a d. • ' ° . ' v 4 i1'\ • • v . d . I C I '. / I i . I -Ar . I • 1 .---4._____ d • a b • C I I I . --___d a 4 • I '---- I l Issuance Date , 4 . I , 4 . . • --- 4 O g na ri i I • 4 °� I • 4 <4 PERMIT 06/30/2017 I Iris 1 Revisions Date No. WATER SERVICE PLAN EXISTING MAIN BEND RESTRAINT AND LINE RECONFIGURATION WATER NOTES: 1 . ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE EAGLE RIVER WATER AND SCALES: z SANITATION DISTRICT [ERWSD] ENGINEERING STANDARDS, MATERIALS SPECIFICATIONS AND DRAWINGS. ALL C HORZ. 1 "-10' MAIN INSTALLATIONS/SYSTEM MODIFICATIONS SHALL BE APPROVED AND INSPECTED BY ERWSD. C 8185 VERT. 1 "=10' o r,WATER SERVICE 8185 WATER MAIN RECONFIGURATION Ill N � 2. THE ENGINEER, OWNER AND ERWSD SHALL BE NOTIFIED [48] HOURS IN ADVANCE OF ANY PLANNED In °' Lo 0Z o w 8185 o- N 8185 CONSTRUCTION. (NJLu 8180 w >o -1- moo ' + o g 8180 z > 00+CNI - 3. ALL WATER MAINS SHALL BE DUCTILE IRON PIPE: AWWA C151 , CLASS 52, WORKING PRESSURE 350 o II II II cy + -6.30 000 o S 8180 Q 0 z II II 8180 PSI, WITH CEMENT-MORTAR LINING, AWWA C104. BITUMINOUS OUTSIDE COATING ONE MIL. THICK. PIPE 5 0 >o CO Q il w ~ -(Ni o< o JOINTS SHALL BE EITHER RESTRAINED JOINT OR PUSH-ON TYPE UTILIZING RUBBER RING GASKET, 8175 �N z� oF- z 8175 x .- ocn 1- AWWA C111 . RESTRAINED JOINT SYSTEMS MUST RECEIVE WRITTEN APPROVAL FROM THE DISTRICT. ALL rn co m7 Zni- o oN ~Now 8175 Lu8175Lo 8175 FITTINGS SHALL BE MADE FROM GRAY-IRON OR DUCTILE IRON AND FURNISHED WITH MECHANICAL wco = r` ei N. moo, r z + - o z 0000 '' (-I r m JOINT ENDS. ALL FITTINGS SHALL BE AT A PRESSURE RATING OF 350 PSI AND SHALL BE WRAPPED Lu o in Lf� In i,- in w o co O w LTJ 0" 00 in �D r 0) 8170 ~ + co 1 moo-( ��- - m II II Q z 8170 - o �w�-+ +‹� r- - WITH EIGHT MILLIMETER MINIMUM THICKNESS POLYETHYLENE MATERIAL IN ACCORDANCE WITH AWWA o co co w LO w o 00 -O II II II MI co + > II II Q o - " 0 8170 wa - ig+ In Ln 8 4-N 8170 STANDARD C105. x M1 000 ° d-cn1- 0 14'f z II II 2 U °ODU z _ - + - 8165 N� oo mu NQS �c~n1- 8165 ii II II n1_ o xQ m Tc 1- °I° 4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ADJUST ALL WATER VALVE BOXES TO THE REQUIRED 8" SS MAIN -Li) -INSULATE WITH 2 RIGID FOAM 8165 CONTRACTOR T0� c cn N n n cn _ 8165 FINAL GRADE. IN ADDITION, VALVE EXTENSIONS SHALL BE INSTALLED SUCH THAT A SIX FOOT VALVE 2.72' INSULATION FOAMULAR 1000 OR EQUAL FIELD VERIFY - I- I- z m o KEY CAN OPERATE THE VALVE. Project Information 8160 1 .74 - 8160 it, A b�...,______€ meg„ 8160 - _ - 8160 5. NO PIPE SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED BY THE ERWSD. 01 8155r MMki -4.75LF 6" DIP 81556. THE MANUFACTURER SHALL FURNISH A CERTIFIED STATEMENT THAT ALL OF THE SPECIFIED TESTS AND -0 8155 14'± 8155 rJ 2.50LF 6 DIP - �° -CONTRACTOR TO INSPECTIONS HAVE BEEN MADE AND THE RESULTS THEREOF COMPLY WITH THE REQUIREMENT OF THE Li „ 5.98LF 12 DIP APPLICABLE STANDARDS HEREIN SPECIFIED. A COPY OF THE CERTIFICATION WILL BE SENT TO THE > 8150 _ 2.00LF 6" DIP- 8150 FIELD VERIFY r2LLu 7.81 LF 6" DIP I1 1 .61 LF 12" DIP ERWSD UPON REQUEST. 6.17LF 6" DIP 8150 7.52LF 12" DIP - 8150 N 1 .83LF 6" DIP BACKFILL WITH FLOWFILL - 7.7. DISTANCES FOR WATER ARE THE HORIZONTAL DISTANCE BETWEEN CENTER OF FITTING TO CENTER OF Ct z 8145 BACKFILL WITH FLOWFILL 8145 TO PROVIDE SECONDARY - VALVE, METER, ETC. THEREFORE, DISTANCES SHOWN ON THE PLANS ARE APPROXIMATE AND COULD ti TO PRC,VIDE SECONDARY 8145 CONTAINMEN- - 8145 VARY DUE TO VERTICAL ALIGNMENT AND FITTING DIMENSIONS. W CO z CON AlIMENT 8140 8140 8. MAINTAIN A MINIMUM OF TEN FEET [10'] HORIZONTAL SEPARATION BETWEEN ALL SANITARY SEWER AND CO w 0+00 8140 8140 WATER MAINS AND SERVICES. Z 0 0 Q 0+00 W 9. FOR ALL PIPE INSTALLATIONS, THE DEPTH OF COVER OVER THE PIPE MEASURED FROM OFFICIAL t itZ 0 STREET GRADE TO THE TOP OF THE PIPE SHALL BE A MINIMUM OF 7 FEET AND SHALL BE KNOWN AS 1. o B THE COVER OVER THE PIPE. IF DIFFICULTIES ARISE WHEN CROSSING INTERFERENCE AND WHERE B J J iTC 0 SPECIFICALLY APPROVED BY ERWSD, DEVIATIONS FROM 7 FEET OF COVER WILL BE PERMITTED. COVER z OVER THE PIPE SHALL BE A MINIMUM OF 7 FEET AND A MAXIMUM OF 9.5 FEET. 10. FIRE HYDRANTS SHALL CONFORM TO ERWSD MATERIALS AND SPECIFICATIONS. FIRE HYDRANT 0 Z Q ASSEMBLIES SHALL INCLUDE ALL PIPE, FITTINGS, VALVES, THRUST BLOCKS, RESTRAINTS, AND MATERIALS 0 LU Q z NECESSARY TO INSTALL THE HYDRANT. 0 11 . INSTALL THRUST BLOCKS AT ALL BENDS, STUBS AND TEES IN WATER LINES. ALL BLOW-OFFS, VALVES W V 0 AND BENDS SHALL BE RODDED OR MECHANICALLY RESTRAINED PER ERWSD DETAILS AS NOTED OR IF z Z Z SOIL CONDITIONS ARE UNSTABLE OR AS DIRECTED BY THE ERWSD. W 12. CHLORINATION AND FLUSHING: ALL WATER MAINS SHALL BE INSTALLED AND CHLORINATED PER ERWSD'S W > 0 z ENGINEERING STANDARDS. THE LINES SHALL BE CHLORINATED IN ACCORDANCE WITH AWWA C-651 , Q "DISINFECTING WATER MAINS." THE PREFERRED METHOD IS TO USE SUFFICIENT CHLORINE TABLETS TO J Z 1- PRODUCE A 25 MG/L SOLUTION. THESE TABLETS SHOULD BE ADHERED TO THE TOP OF THE PIPE ort z w WITH PERMATEX CLEAR R.T.V. CHLORINATION OF 16 INCH AND LARGER PIPE REQUIRES A CHLORINE Q 0 SLURRY. THE CHLORINATION OF ANY FINISHED PIPELINE SHALL BE COMPLETED PRIOR TO HYDROSTATIC o 0 TESTING. W IL I 13. ALL VALVES ARE TO BE LOCATED ON THE PROPERTY LINE EXTENSIONS EXCEPT FOR TAPPING TEES J C5 ry •,1- 5 0 WHERE AN ADDITIONAL VALVE SHALL BE PLACED ON THE TAPPING TEE. OTHER VALVE LOCATIONS MAY p o BE REQUIRED AS SHOWN ON THE PLANS. CO m o N- .,1- 12, 14. WHEN IT IS NECESSARY TO LOWER OR RAISE WATER LINES AT STORM DRAINS AND OTHER UTILITY LLJ> • CROSSINGS, A MINIMUM CLEARANCE OF [ONE [1] FOOT SHALL BE MAINTAINED BETWEEN THE OUTSIDE cn OF PIPES. g 15. PRIOR TO INSTALLATION OF WATER MAINS, ROAD CONSTRUCTION MUST HAVE PROGRESSED TO AT LEAST THE "SUB-GRADE" STATE. m w w 16. BEFORE ANY TAPS ARE MADE FROM MAINS, APPLICATION[S] FOR THE TAPS MUST BE RECEIVED AND in cc 4 APPROVED BY THE ERWSD. Sheet Information 0 m f ti 17. ALLPRIOR COMBINATIONTOTHERELEASE FIRE LINEOF THE AND DOMESTICWATERMAINS.TAPS MUST BE INSPECTED AND APPROVED BY ERWSD Sheet Title: COLORADO8I' A 1 N 18. THE WATER QUALITY CONTROL DIVISION OF THE COLORADO DEPARTMENT OF PUBLIC HEALTH AND WATER MAIN & C>j . KNOW VIHAT 's [�fl (w IC /III RI100I IOU ' • ' r N ENVIRONMENT [CDPHE] REQUIRES ALL WATER LINE CONTRACTORS TO POSSESS A CURRENT DISCHARGE SERVICE PLAN AND o PERMIT FOR DISCHARGES OF CHLORINATED AND PROCESS WATERS ASSOCIATED WITH THE INSTALLATION • cCALL 811 2-BUSINESS DAYS IN ADVANCE OF NEW MAINS OR CONDUITS. CONTACT CDPHE WATER QUALITY CONTROL DIVISION AT 303-692-3539 PROFILE BEFORE YOU DIG, GRADE OR EXCAVATE FOR FOR INFORMATION ON OBTAINING THE REQUIRED PERMIT. Sheet Number: 0 z MARKING OF UNDERGROUND MEMBER UTILITIES 19. CONTRACTOR TO COORDINATE HORIZONTAL AND VERTICAL LOCATIONS OF UTILITY SERVICE CONNECTIONS o MARTIN/MARTIN ASSUMES NO RESPONSIBILITY FOR UTILITY TO BUILDING WITH MECHANICAL/PLUMBING PLANS PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF c < LOCATIONS. THE UTILITIES SHOWN ON THIS DRAWING HAVE BEEN �� ANY DISCREPANCIES. C330 I- o PLOTTED FROM THE BEST AVAILABLE INFORMATION. IT IS, HOWEVER, 10 5 0 10 20 THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY THE SIZE, SCALE: 1 "-10' o 0 MATERIAL, HORIZONTAL AND VERTICAL LOCATION OF ALL UTILITIES ALL DIMENSIONS SHOWN ARE U.S. SURVEY FEET PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION. o < DPA Project: 15914.00.000 w o 1 2 3 4 1 5 6 COPYRIGHT 2016 -DAVIS PARTNERSHIP,P.C.