HomeMy WebLinkAboutB17-0340_E-001.75_1507837298.pdfPOWER LEGEND (Not all symbols listed below are used on these drawings) SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE, HALF SWITCHED DUPLEX RECEPTACLE, CEILING MOUNTED DUPLEX RECEPTACLE, FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED SPECIAL RECEPTACLE SPECIAL RECEPTACLE, FLOOR MOUNTED JUNCTION BOX, WALL OR CEILING MOUNTED JUNCTION BOX, FLOOR MOUNTED DISCONNECT SWITCH (NON-FUSED) DISCONNECT SWITCH (FUSED) VARIABLE SPEED DRIVE WITH DISCONNECT UTILITY METER ELECTRICAL PANELBOARD, CONTROL PANEL, OR OTHER CABINET AS NOTED PLUG MOLD (MULTI-OUTLET ASSEMBLY) CONDUIT EXPOSED CONDUIT TURNING DOWN CONDUIT TURNING UP CONDUIT CAPPED MAIN SWITCHBOARD/DISTRIBUTION CENTER CURRENT TRANSFORMER GENERATOR ANNUNCIATOR PANEL CONDUIT, UNDERGROUND OR CONCEALED IN FLOOR AS ALLOWED PER SPECIFICATIONS BRANCH CIRCUIT HOME RUN, NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS, SUBSCRIPTS INDICATE PANEL & CIRCUITS DESCRIPTION SYMBOL DESCRIPTION SYMBOL CLG J J M WM A-1,3,5 T CT GANN MOTOR CONDUIT CONCEALED GROUND BAR TRANSFORMER THERMOSTAT SINGLE POLE SWITCH (SUBSCRIPT DENOTES SWITCHING) TWO POLE SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH KEY OPERATED SWITCH MANUAL SWITCH, HORSEPOWER RATE DIMMER SWITCH LOW VOLTAGE SWITCH VARIABLE SPEED/SPEED CONTROLLER SWITCH EXPLOSION PROOF SWITCH THERMAL OVERLOAD SWITCH MOMENTARY CONTACT SWITCH COMBINATION SWITCH AND DUPLEX RECEPTACLE PHOTOCELL TIME CLOCK SWITCH WITH PILOT LIGHT LOCATOR (CONTINUOUSLY LIGHTED HANDLE) PUSH BUTTON OCCUPANCY SENSOR - WALL MOUNTED IR=INFRARED, US=ULTRASONIC, DT=DUAL TECHNOLOGY Sa S2 S3 S4 SK SM SD SPI SP SLV SVS SEP STO SMC S TC ABBREVIATIONS LEGEND AMPERES ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ANNUNCIATOR ABOVE RAISED FLOOR AIR SAMPLING SMOKE DETECTION AUTOMATIC TRANSFER SWITCH BELOW FINISHED GRADE MOTOR CIRCUIT PROTECTOR SEE MECHANICAL EQUIPMENT SCHEDULE MINIMUM MAIN LUGS ONLY MANUAL TRANSFER SWITCH NORMALLY CLOSED NIGHT LIGHT NORMALLY OPEN NOT TO SCALE CONDUIT CABLE TELEVISION CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION EXISTING EMERGENCY EMERGENCY MAIN DISTRIBUTION CENTER EXPLOSION PROOF EMERGENCY POWER OFF EMERGENCY VENTILATION ON/OFF ELECTRIC WATER COOLER FIRE ALARM GROUND GENERATOR CONTROL PANEL GROUND FAULT CIRCUIT INTERRUPTER HAND OFF AUTOMATIC ISOLATED GROUND MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION CENTER TRANSFORMER WEATHER PROOF WITHOUT WITH VARIABLE FREQUENCY DRIVE VOLTS UNINTERRUPTIBLE POWER SUPPLY UNLESS OTHERWISE NOTED UNDER GROUND UNDER FLOOR TYPICAL TRANSIENT VOLTAGE SURGE SUPPRESSER TAMPER PROOF SUB-DISTRIBUTION CENTER STAND-BY PULL BOX ON SITE WORK FORCE OWNER FURNISHED, OWNER INSTALLED OWNER FURNISHED, CONTRACTOR INSTALLED ON CENTER ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE OF DEVICE, +6" ABOVE COUNTER OR BACK SPLASH NOT IN CONTRACT DESCRIPTION SYMBOL DESCRIPTION SYMBOL REFERENCE SYMBOLS LEGEND (Not all symbols listed below are used on these drawings) KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE MECHANICAL EQUIPMENT REFERENCE EXISTING TO REMAIN EXISTING TO BE REMOVED EXISTING TO BE RELOCATED EXISTING TO REMAIN - REPLACE DEVICE DESCRIPTION DESCRIPTION SYMBOL A-1 1 LC1 UH E R RL ER ONE-LINE DIAGRAM LEGEND (Not all symbols listed below are used on these drawings) DISCONNECT SWITCH DISCONNECT SWITCH, FUSED CIRCUIT BREAKER PANELBOARD "A" EM=ENERGY METER, PM=POWER METER, CM=CIRCUIT MONITOR VOLTMETER TEST SWITCH AMMETER TEST SWITCH VOLTMETER AMMETER ENGINE GENERATOR CONTACTOR/RELAY/CAPACITOR (AS NOTED) TRANSFER SWITCH - ATS=AUTOMATIC, MTS=MANUAL GROUND FAULT INTERRUPTER TRANSIENT VOLTAGE SURGE SUPPRESSER SHUNT TRIP TERMINATIONS LB=LOAD BREAK, NLB=NO LOAD BREAK DRAW-OUT DEVICE PLUG-IN DEVICE ELECTRICALLY OPERATED MECHANICAL INTERLOCK ELECTRICAL INTERLOCK, SUBSCRIPT INDICATES INTERLOCKED GROUP KIRK KEY INTERLOCK, SUBSCRIPT INDICATES INTERLOCKED GROUP SHORT CIRCUIT CURRENT AVAILABLE SERVICE WEATHERHEAD EQUIPMENT ENCLOSURE METER SERVICE ENTRANCE TRANSFORMER POTENTIAL TRANSFORMER CURRENT TRANSFORMER STEP DOWN TRANSFORMER, ## INDICATES KVA GROUND FUSE K-RATED STEP DOWN TRANSFORMER ## INDICATES KVA, # INDICATES K RATING DESCRIPTION SYMBOL DESCRIPTION SYMBOL T ## OR ISCA K a E a M A PM VS V GFI XXX SYMBOL M (Not all symbols listed below are used on these drawings) T PM CONTROLS LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL (Not all symbols listed below are used on these drawings) TK ## AS A G TVSS ST EO P MDC MCC MCB MAX IG HOA GFCI GCP G FA EWC EVO EPO EP EMDC EM (E) CCTV CB CATV C BFG ATS ASSD ARF ANN AFG AFF AC A XFMR WP W/O W/ VFD V UPS UON UG UF TYP TVSS TP SDC SB PB OSWF OFOI OFCI OC NTS NO NL NIC NC MTS MLO MIN MEC MCP WIREMOLD (SURFACE RACEWAY) SHADING INDICATES EMERGENCY SYSTEM TEXT INDICATES PANEL AND CIRCUIT DESIGNATION SWITCH WITH PILOT LIGHT (PILOT LIGHT IS 'ON' WHEN SWITCH IS 'ON') SEE FEEDER/MEC/TRANSFORMER SCHEDULES FOR FEEDER SIZE KEY NOTE REFERENCE M LPA-# TYPICAL CIRCUIT NUMBER TYPICAL LUMINAIRE TYPE 1 TG# LIGHTING CONTROL / EQUIPMENT REFERENCE TYPICAL ROOM REFERENCE (TOP = RM #, BOTTOM = FLR) X X EXISTING TO BE REMOVED AND REPLACED RR EMERGENCY SHUNT RELAY ESR 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 2:15:50 PM 15924.00 E-001.75 ELECTRICAL LEGENDS & NOTES 06/30/17 PERMIT EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657 GENERAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. FOR REMODELING, WORK INCLUDED IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN AND ORDERING MATERIALS OR EQUIPMENT. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. DEMOLITION NOTES: 1. 2. 3. 4. 5. 6. 7. UNLESS NOTED OTHERWISE, BOLD ITEMS INDICATE EQUIPMENT, DEVICES, ETC. TO BE REMOVED. SEE SPECIFICATION SECTION 260500 FOR REMODEL/DEMOLITION DETAILED REQUIREMENTS. DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED. CONTRACTOR SHALL VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT DOCUMENTS PRIOR TO QUOTATION. NO EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS. REWORK EXISTING TERMINATIONS, CONNECTIONS, CONDUIT, WIRING, ETC. TO ACCEPT NEW WORK. MAINTAIN CIRCUIT CONTINUITY TO EXISTING CIRCUITS AND DEVICES TO REMAIN OR REMODEL/DEMOLITION DETAILED REQUIREMENTS TO BE RELOCATED. PRIOR TO COMMENCEMENT OF ANY DEMO WORK, CONFIRM EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ALL WIRING AND EXPOSED CONDUIT AND CONDUIT SUPPORTS BACK TO POINT OF ORIGIN OR NEXT DEVICE TO REMAIN. REMOVED ITEMS SHALL BE TURNED OVER TO THE OWNER, UNLESS NOTED OTHERWISE, AND STORED IN THE AREA DESIGNATED BY THE OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER CHOOSES NOT TO ACCEPT. WHERE EXISTING CONDUITS ARE SHOWN TO BE REMOVED AND HAVE BEEN ROUTED IN CONCRETE FLOOR SLABS, CONCRETE WALLS OR CONCRETE CEILINGS, THEY SHALL BE CUT BACK FLUSH WITH CONCRETE. FILL WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. REUSE EXISTING CONDUIT WHERE CURRENT NEC AND LOCAL CODE REQUIREMENTS ARE MAINTAINED. PROVIDE NEW CONDUIT AND WIRE FOR NEW INSTALLATIONS AND EXTENSION OF EXISTING INSTALLATIONS. REUSE EXISTING CONDUIT IN PLACE, DO NOT REINSTALL EXISTING CONDUIT. PROVIDE LABELING PER SPECIFICATIONS FOR REUSED CONDUIT. RELOCATED EQUIPMENT AND DEVICES ARE TO BE CLEANED OF ALL FOREIGN MATERIAL. REPLACE EQUIPMENT OR DEVICES WHICH ARE DEFECTIVE OR DAMAGED DURING RELOCATION. WHERE EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FINISH. BLANK COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE, UNLESS NOTED OTHERWISE. POWER PLAN NOTES: 1. 2. 3. 4. 5. 6. 7. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. PROVIDE FUSES SIZED PER EQUIPMENT MANUFACTURER'S REQUIREMENTS. DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY AND SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS TO SUIT EQUIPMENT AND SPACE. DISCONNECT SWITCHES SHALL BE WITHIN SIGHT OF THE EQUIPMENT THEY SERVE AND MOUNTED AT 6'-3", MAXIMUM, TO TOP OF CABINET. MAINTAIN NEC WORK SPACE REQUIREMENTS. ALL DEVICES AND COVERPLATES FED FROM AN EMERGENCY CIRCUIT SHALL BE RED. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V CIRCUIT. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. WHERE CIRCUITS ARE COMBINED WITHIN A SINGLE CONDUIT, PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES. ONE-LINE DIAGRAM NOTES: 1. 2. 3. 4. 5. 6. 7. PANELBOARDS INDICATED ON ONE LINE DIAGRAMS DO NOT SHOW ALL BRANCH CIRCUITS. REFER TO PANELBOARD SCHEDULE(S). EQUIPMENT SHOWN SHADED REPRESENTS STAND-BY POWERED SERVICES. PROVIDE CONTINUOUS #10 INSULATED COPPER CONDUCTOR FOR BONDING THE EQUIPMENT GROUNDING TERMINAL BUSSES OF THE NORMAL AND ESSENTIAL BRANCH CIRCUIT PANELBOARDS SERVING THE SAME INDIVIDUAL PATIENT VICINITY. PANEL NAMING LEGEND "1234" 1: N-NORMAL, S-STANDBY, E=EMERGENCY, EQ=EQUIPMENT, C=CRITICAL, LS=LIFE SAFETY 2: H=277/480V, L=120/208V, LCP-LIGHTING CONTROL PANEL. 3: FLOOR DESIGNATION (B=BASEMENT, 1=1ST FLOOR ,ETC.) 4: PANELBOARD DESIGNATION (LENGTH AS REQUIRED) ARBITRARY A,B,C, DESIGNATION PER FLOOR. USE K FOR KITCHEN, ETC. ADJUSTABLE BREAKERS SHALL BE SOLID STATE TRIP. CIRCUIT BREAKER TRIP FUNCTIONS: L=LONG TIME S=SHORT TIME I=INSTANTANEOUS G=GROUND FAULT Z=ZONE SELECT INTERLOCK EXISTING ONE-LINE DIAGRAM TAKEN FROM OWNER FURNISHED DRAWINGS. EXISTING INFORMATION SHOWN OTHER THAN LOCATIONS IMPACTED BY NEW WORK HAS NOT BEEN VERIFIED. COORDINATE MOUNTING, CONDUIT, WIRE, AND OCPD SIZE FOR SPD'S WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. M E C H A N I C A L E Q U I P M E N T S C H E D U L E GENERAL NOTES: A. Prior to work, verify electrical requirements (voltage, amperage, recommended OCPD, conductors, and disconnect) for each piece of equipment. B. Prior to work, verify exact location for each piece of equipment. C. Coordinate and provide all field connections as required. D. Coordinate 120V power connections to dampers and other control circuits. Group equipment control circuits such that failure of one control circuit does not affect operation of other equipment. For example, do not connect a damper associated with one air handling unit to the same branch circuit as dampers associated with a different air handling unit. E. Feeders, breakers, disconnects, and fusing applies to field-installed and/or factory-installed equipment. F. Coordinate location of VFD(s) and working space clearances. If installed remote from equipment, provide circuit connection from VFD to motor(s). SPECIFIC NOTES: 1. Connect equipment to emergency power. Key # Item HP FLA Load Eq Load (VA) Voltage Feeders Protection Notes Wire Ground Conduit Breake r Disconnect Fuse ACC 2 CONDENSING UNIT 0 24 A 0 VA 19870 VA 480V 3ph 2#10 #10G 3/4" 40 A 30 A CRAC 2 AIR CONDITIONER 0 1 A 0 VA 1164 VA 480V 3ph 3#12 #12G 3/4” 15 A 30 A 3 A 10/12/17