Loading...
HomeMy WebLinkAboutB17-0340_E-011.75_1507837260.pdf 14: IA e IS c 4 Ftp Agin. 10/12/17 1111110111111 TRANSFORMER SCHEDULE FEEDER SCHEDULE ii ii KEY CONDUCTORS "C I MORIN E KEY HV FLA LV FLA HV PROT HIGH VOLTAGE FEEDER LV PROT LOW VOLTAGE FEEDER GROUNDING DIMENSIONS WEIGHT BTUH NOTE 40.3 G 3# 8 . 1# 100.3 G 3# 1 8 G 1 E 1# 8 G 1 1/2 480 V 208 V CCT BRKR CONDUCTORS "C CCT BRKR CONDUCTORS "C CNDTRS "C HIGH WIDE DEEP OTPT - 100.4 G 4# 1/0 AL 1# 6 AL G 2 T25 52.1 120.2 70 A 2 P 2# 4 ,1# 8 G 1 150 A 2 P 3# 3/0 AL ,1# 4 AL G 2 1# 4 AL 3/4 30.00 17.00 16.00 235 125.4 G 4# 2/0 AL MIMI 1# 4 AL G 2 T15 18.0 41.6 25 A 3 P 3# 10 ,1# 10 G 3/4 60 A 3 P 4# 6 ,1# 10 G 1 1# 8 3/4 27.00 20.13 16.00 310 2806 200.4 G 4# 250 AL , 1# 4 AL G 2 1/2 T30 36.1 83.3 45 A 3 P 3# 6 ,1# 10 G 1 100 A 3 P 4# 1 ,1# 8 G 1-1/2 1# 6 3/4 30.00 20.13 16.00 370 5753 225.4 G 4# 350 AL 1# 2 AL G 3 U 111 1111 II 111 250.4 G 4# 350 AL , 1# 2 AL G 3 T4554.1 124.9 70 A 3 P 3# 4 ,1# 8 G 1-1/4 150 A 3 P 4# 3/0 AL ,1# 4 AL G 2 1# 4 AL 3/4 39.25 26.13 20.00 480 7425 _ _ - _ _ 400.4 G 2 [ 4# 250 AL 1# 1 AL G 2 1/2 1 T75 90.2 208.2 110 A 3 P 3# 1 ,1# 6 G 1-1/2 250 A 3 P 4# 350 AL ,1# 1/0 AL G 3 1# 1/0 AL 3/4 39.25 30.00 20.00 675 10549 800.4 G 3 [ 4# 500 AL , 1# 3/0 AL G 3 1 T150 180.4 416.4 225 A 3 P 3# 350 AL ,1# 2 AL G 2-1/2 500 A 3 P 2[4# 350 AL ,1# 3/0 AL G 31 1# 3/0 AL 1 46.63 32.00 27.00 925 16592 1000.4 G 4 [ 4# 350 AL , 1# 4/0 AL G 3 ] D s NOTES: 1.) PRIMARY AND SECONDARY O.C.PROTECTION PER NEC 450.3. 1200.4 G 4 [ 4# 500 AL , 1# 250 AL G 3 1 Avi 2.) BONDING AND GROUNDING CONDUCTOR PER NEC 250.66. 2000.4 G_ 6 [ 4# 600 AL , 1# 400 AL G 3 1/2 1 3.) CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. ALUMINUM CONDUCTORS ARE BASED ON TYPE XHHW-2 COMPACT 600V. 3000.4 G_ 8 [ 4# 750 AL , 1# 600 AL G 4 1 4.) SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. MEC SEE MECH'L EQUIPMENT SCHEDULE I,A K I N t KS H I P 5.) DIMENSIONS,WEIGHTS&BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. XFMR SEE TRANSFORMER SCHEDULE 6.) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K-RATED TRANSFORMERS. NOTE: ALUMINUM CONDUCTORS ARE BASED 7.) FOR K-RATED TRANSFORMERS,PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS,LOW VOLTAGE PANELBOARD,DISCONNECTS AND/OR LOAD. ON TYPE XHHW-2 COMPACT 600V ARCHITECTS 2901 Blare Sr ,eetSite 10C Darner 1 Denver, CO 8020. 303.861.855E Consultant ROOF RTU RETURN 30 HP O ISCA=4,975 ISCA=4,787 CATO R I RUM A ISCA=15,629ISCA=16,512 & ASSOCIATES , CO . VFD NH4A NL4A NH4B NL4B XFMR\)X El 4CD T XFMR 896 Tabor Street 420 W.Lincolnway 75 �� Lakewood.CO 80401 Cheyenne,WY 82001 I 303.232.6200(P) 307.274.3830(P) 303.233.3701(F) 303.233.3701(F) X ISCA=11,088 ISCA=5,315 X- ISCA=9,956 ISCA=5,019 www.catorruma.com C C FOURTH FLOOR - ISCA=4,834 II ISCA=16,569 H3B L3C NH3A NL3A XFMR ' 75 T 411) ,ti\NN,,,til�' �<<,:i,,. II/ iSr ISCA=7,417 X ISCA=4,151 X ISCA=11,991 ISCA=5,024 i .N. .,41 77 :d 41821 g' L1 THIRD FLOOR - "0.& itea■( .F./lffJ .06,,,"....•0:,T.,5,-��yh 250.5GX -ISCA=5,059 II I- L2D NL2D1 NL2D2 • , 200A3P Issuance • MCB �00.4G J o = PERMIT 06/30/17 200A3P NL2LAB SHC X-RAY ( __0.4G.) 250.5GX X ISCA=5,808 Revisions Date • ISCA=3,759 • (250..5GX 85A3P X- XFMR C C X ISCA=2,600 112.5 U T-K4 "TNL2LAB" 1ST FLR C-SEC 2ND FLR LDRP ATRIUM, POST ELEC, FCU-1 SPARE X TO ATS-8-CR TO ATS-9-EQ N 2ND FL 2ND FL OLAB LAB 45 ATRIUM COVING HALLWAY ROOM ELEC PARTUM LOBBY, -- o a LTG LTG LTG LTG LTG LTG RM.LTG NURSE WAITING o LIADS L DS BAY LTG LTG N Ce)It U - - XFMR 90.46X1 50.3GX 175.3G 150.4G 400.4GX - ISCA=3,068 ISCA=2,861 SPARE SPARE ISCA=17,511 • • • • • • • • • • NH2A NL2B NL2C •85A3P 20A1P 20A1P • 70A3P • 100A3P 70A3P 100A3P 450A3P • 20A1P • 20A1P • 20A1P • 20A1P 20A1P 20A1P 20A1P 15A1P 20A1P • 175A3P • 150A3P • 350A3P 40010> 46 XFMR 100.4G 1 DISTRIBUTION PANEL"H2A" X ISCA=23,147 X ISCA=13,142 - ISCA=3,134 Project Infornmition 800A,277/480V,3PH,4W SECOND FLOOR SHC MRI MOBILE - ISCA=5,177 CATH LAB ISCA=19,852II eg I _J 175A3P �� NH1A NL1A X ISCA=16,207 ELEVATOR ((FM75 XFMR) N- 1.0 F - X ISCA=15,384 - ISCA=5,380 Z N- 0 CO E FIRST FLOOR E l' 2 0 0 U UNLBA N (5 o „ ISCA=7,916 ISCA=16,895 XFMR � J TO"CDHBB" HBA1 125.4X MRI0 U VIA ATS-12-CR cj ISCA=8,170 CB2 Y - N T 150 • • o TO QDHBA r PAD MOUNTED VIA ATS-13-EQ (-1480/277V XFMR cdr-r - (Z) 3 0) WITH METERING TO QDHRA O TO ATS-10-CR X ISCA=17,210 (i BASE TO"DPA1" TO"EDPA" VIA ATS-14-EQ iSi 4t TO ATS-11-EQ 160KVA a--+ r C5 UPS O ISCA=33,900 O ISCA=34,412 ♦ ) L 1200.4G 600.4G 800.4G 1200.4G r 250.4G 400.4G2 CD 230.3G 70.4G CO 125.46 CD 90.46X2 �/� COci J SPD CO c,-) MIO CO SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARES 000.46) 3000AF 150AF 100AF 600AF 800AF 1200AF 600AF 800AF 1200AF 2000AF 250AF 250AF 400AF 400AF 400AF 400AF 600AF (2) (2) 60A3P 60A3P 60A3P 60A3P 60A3P 60A3P 30A3P 30A3P 30A3P 125A3P 125A3P 125A3P 125A3P 15A3P 40A3P 40A3P 35A3P 20A3P 20A3P 125A3P 90A3P 20A3P 60A3P (3)400A3P , • • • • • • • 600AF 250AF SPACE • • • • • SPACE • • • • • 100AF S SPACE SPACE SPACE 3000AT • 100AT • 450AT • 800AT • 1200AT • 800AT • 800AT • 1200AT 2000AT • 175AT • 250AT • 400AT • 250AT • 250AT • • • • • 1I Co Co LSIGZ ' LSIGZ LSIGZ LSIGZ LSIGZ LSIGZ LSIGZ LSIGZ LSI LSI LSI LSI LSI LSI I L- - - - &I -Ibi - - - - - - - - - - - - - - - - -J I - - --- - - --- - - --- - - --- - - --- - - --- - - --- - - - - --- - - --- - - ISCA=40,361 X MAIN DISTRIBUTION CENTER"MDC" 3,000A BUS,277/480V,3-PH,4W 6#3/0G 5, COLD BLDG. WATER STEEL Sheet InbrrrEtion PIPE BASEMENT A EXTEND ALL EXISTING A Sheet Ttle: WATER PIPE GROUNDING ELECTRODE ELECTRICAL ONE-LINE DIAGRAM - WEST NORMAL ENTRANCE - EXISTING ELECTRICAL ONE-LINE CONDUCTORS TO NEW WATER ENTRY PIPE DIAGRAM - WEST NORMAL LOCATION. SCALE:NONE FOR REFERENCE ONLY ENTRANCE Sheet N.wirer 2 E _O 1 1 , 75a Ce In N N. O M EPA Project: 15924.00 OPCRG-fF -DSAS PPRR -IP, 1 2 3 4 1 5 1 €