HomeMy WebLinkAboutB17-0340_E-011.75_1507837301.pdf~~~ ~ ~~ ~ TRANSFORMER SCHEDULE KEY HV FLA LV FLA HV PROT HIGH VOLTAGE FEEDER LV PROT LOW VOLTAGE FEEDER GROUNDING DIMENSIONS WEIGHT BTUH NOTE 480 V 208 V CCT BRKR CONDUCTORS "C CCT BRKR CONDUCTORS "C CNDTRS "C HIGH WIDE DEEP OTPT T25 52.1 120.2 70 A 2 P 2 # 4 , 1 # 8 G 1 150 A 2 P 3 # 3/0 AL , 1 # 4 AL G 2 1 # 4 AL 3/4 30.00 17.00 16.00 235 T15 18.0 41.6 25 A 3 P 3 # 10 , 1 # 10 G 3/4 60 A 3 P 4 # 6 , 1 # 10 G 1 1 # 8 3/4 27.00 20.13 16.00 310 2806 T30 36.1 83.3 45 A 3 P 3 # 6 , 1 # 10 G 1 100 A 3 P 4 # 1 , 1 # 8 G 1-1/2 1 # 6 3/4 30.00 20.13 16.00 370 5753 T45 54.1 124.9 70 A 3 P 3 # 4 , 1 # 8 G 1-1/4 150 A 3 P 4 # 3/0 AL , 1 # 4 AL G 2 1 # 4 AL 3/4 39.25 26.13 20.00 480 7425 T75 90.2 208.2 110 A 3 P 3 # 1 , 1 # 6 G 1-1/2 250 A 3 P 4 # 350 AL , 1 # 1/0 AL G 3 1 # 1/0 AL 3/4 39.25 30.00 20.00 675 10549 T150 180.4 416.4 225 A 3 P 3 # 350 AL , 1 # 2 AL G 2-1/2 500 A 3 P 2 [ 4 # 350 AL , 1 # 3/0 AL G 3 ] 1 # 3/0 AL 1 46.63 32.00 27.00 925 16592 NOTES: 1.) PRIMARY AND SECONDARY O.C. PROTECTION PER NEC 450.3. 2.) BONDING AND GROUNDING CONDUCTOR PER NEC 250.66. 3.) CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. ALUMINUM CONDUCTORS ARE BASED ON TYPE XHHW-2 COMPACT 600V. 4.) SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. 5.) DIMENSIONS, WEIGHTS & BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. 6.) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K-RATED TRANSFORMERS. 7.) FOR K-RATED TRANSFORMERS, PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS, LOW VOLTAGE PANELBOARD, DISCONNECTS AND/OR LOAD . FEEDER SCHEDULE KEY CONDUCTORS "C 40.3 G 3 # 8 , 1 # 10 G 1 100.3 G 3 # 1 , 1 # 8 G 1 1/2 100.4 G 4 # 1/0 AL , 1 # 6 AL G 2 125.4 G 4 # 2/0 AL , 1 # 4 AL G 2 200.4 G 4 # 250 AL , 1 # 4 AL G 2 1/2 225.4 G 4 # 350 AL , 1 # 2 AL G 3 250.4 G 4 # 350 AL , 1 # 2 AL G 3 400.4 G 2 [ 4 # 250 AL , 1 # 1 AL G 2 1/2 ] 800.4 G 3 [ 4 # 500 AL , 1 # 3/0 AL G 3 ] 1000.4 G 4 [ 4 # 350 AL , 1 # 4/0 AL G 3 ] 1200.4 G 4 [ 4 # 500 AL , 1 # 250 AL G 3 ] 2000.4 G 6 [ 4 # 600 AL , 1 # 400 AL G 3 1/2 ] 3000.4 G 8 [ 4 # 750 AL , 1 # 600 AL G 4 ] MEC SEE MECH'L EQUIPMENT SCHEDULE XFMR SEE TRANSFORMER SCHEDULE NOTE: ALUMINUM CONDUCTORS ARE BASED ON TYPE XHHW-2 COMPACT 600V NONE SCALE: ELECTRICAL ONE-LINE DIAGRAM - WEST NORMAL ENTRANCE - EXISTING FOR REFERENCE ONLY ELEVATOR TO "EDPA" COLD WATER PIPE BLDG. STEEL #3/0G BASEMENT FIRST FLOOR SECOND FLOOR CATH LAB DISTRIBUTION PANEL "H2A" 800A, 277/480V, 3PH, 4W ISCA=23,147 ISCA=20,503 ISCA=5,808 200A3P THIRD FLOOR ISCA=7,417 ISCA=4,151 FOURTH FLOOR 30 HP 3[4#300KCMIL, 1#1/0G, 2 1/2"C.] TO ATS-10-CR TO ATS-11-EQ 2ND FL LAB LTG LOADS 2ND FL LAB LTG LOADS ISCA=2,600 "TNL2LAB" SHC MRI RTU RETURN 85A3P LSIGZ 175A3P ISCA=16,207 LSIGZ G 3#3/0, 1#4G, 2"C. SHC X-RAY LSIGZ LSIGZ LSIGZ LSIGZ N LSIGZ LSI LSI LSI LSI SPACE LSI LSI 65,000 AIC MAIN DISTRIBUTION CENTER "MDC" LSIGZ 3,000A BUS, 277/480V, 3-PH, 4W SPACE 600AF ROOF VIA ATS-12-CR TO "DPA1" TO ATS-9 -EQ TO ATS-8-CR VIA ATS-13-EQ VIA ATS-14-EQ ISCA=40,361 ISCA=33,900 PAD MOUNTED 480/277V XFMR WITH METERING BASE TO "CDHBB" TO QDHBA TO QDHRA SPACE MOBILE (2) SPACE 250AF (2) EXTEND ALL EXISTING WATER PIPE GROUNDING ELECTRODE CONDUCTORS TO NEW WATER ENTRY PIPE LOCATION. ISCA=7,916 ISCA=8,170 ISCA=17,210 ISCA=16,895 ISCA=11,088 ISCA=15,629 ISCA=5,315 ISCA=4,975 ISCA=11,991 ISCA=16,569 ISCA=5,024 ISCA=4,834 ISCA=13,142 ISCA=17,511 ISCA=3,134 ISCA=3,068 ISCA=15,384 ISCA=19,852 ISCA=5,380 ISCA=5,177 ISCA=9,956 ISCA=16,512 ISCA=5,019 ISCA=4,787 ELEC, LOBBY, WAITING LTG POST PARTUM NURSE BAY LTG ATRIUM, ELEC RM. LTG LDRP ROOM LTG 2ND FLR HALLWAY LTG C-SEC COVING LTG 1ST FLR ATRIUM LTG SPARE FCU-1 ISCA=2,861 ISCA=5,059 ISCA=3,759 ISCA=34,412 M M F 30A3P ~ 30A3P 60A3P 20A3P 60A3P ~~~ ~40A3P ~~ ~20A3P 60A3P 15A3P 60A3P ~40A3P 30A3P ~ ~~~ 35A3P 60A3P 20A3P SPACE SPARES (3)400A3P 45 T-K4 2000AF 2000AT 400AF 400AT NL2LAB 350A3P 600AF 800AT 90.4GX2 90A3P SPD XFMR 400AF 250AT 800AF 800AT 225.4FG H3B 150AF 100AT L3C 20A1P 250.5GX 175.3G MRI CB 20A1P 15A1P 400AF 250AT 3#2/O, 1#2/O G, 1#2/O IG, 2-1/2"C. HBA1 L2D 200A3P MCB 60.4G NL2D2 100A3P 600AF 450AT NL2D1 90.4GX1 1200AF 1200AT 175A3P 150A3P 20A1P 70.4G 20A1P 20A1P 20A1P 1200AF 1200AT 3000AF 3000AT 70A3P 70A3P 100A3P 20A1P 50.3GX ST ST 60A3P 112.5 T 85A3P 400.4GX XFMR 20A1P 250.4G 600.4G 250.5GX 100AF 100.4G 400AF 250AT VFD SPARE 450A3P 400.4G2 20A1P 1200.4G 250AF 175AT 250.5GX 100AF 20A1P 150.4G 75 T XFMR XFMR 75 T XFMR XFMR 75 T XFMR XFMR NH4A NL4A NH3A NL3A NH4B NL4B 125.4G 125.4G 125.4G 125A3P 125A3P 45 T XFMR XFMR NH2A NL2B 75 T XFMR XFMR NH1A NL1A 125A3P 125A3P 125.4G 125.4G 800.4G 1200.4G 800AF 800AT XFMR 230.3G XFMR UPS 160KVA UNLBA 150 T SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE 250AF 600AF SPARE SPARE SPARE 60A3P SPARE SPARE 125A3P SPARE HBA NL2C 100.4G 3000.4G 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 2:15:53 PM 15924.00 E-011.75 ELECTRICAL ONE-LINE DIAGRAM - WEST NORMAL ENTRANCE 06/30/17 PERMIT EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657 10/12/17