HomeMy WebLinkAboutB17-0340_E-014.75_1507837260.pdf 1 2 3 4 5 1EF il'71141. .1A.irb ' loop.% 10/12/17 TRANSFORMER SCHEDULE FEEDER SCHEDULE KEY CONDUCTORS "C KEY HV FLA LV FLA HV PROT HIGH VOLTAGE FEEDER LV PROT LOW VOLTAGE FEEDER GROUNDING DIMENSIONS WEIGHT BTUH NOTE 40.3 G 3# 8 1# 10 G 1 _ 100.3 G 3# 1 1# 8 G 1/2 480V 208V CCTBRKR CONDUCTORS "C CCTBRKR CONDUCTORS "C CNDTRS "C HIGH WIDE DEEP OTPT 230.3 G 3# 300 AL 2 1# 2 AL G 2 1/2 _ I.. ' . T25 52.1 120.2 70 A 2 P 2# 4 ,1# 8 G 1 150 A 2 P 3# 3/0 AL ,1# 4 AL G 2 1# 4 AL 3/4 30.00 17.00 16.00 235 100.4 G 4# 1/0 AL 1# 6 AL G 2 T15 18.0 41.6 25 A 3 P 3# 10 ,1# 10 G 3/4 60 A 3 P 4# 6 ,1# 10 G 1 1# 8 3/4 T 27.00 20.13 16.00 310 2806 125.4 G 4# 2/0 AL , 1# 4 AL G 2 I. " T30 36.1 83.3 45 A 3 P 3# 6 1# 10 G 1 100 A 3 P 4# 1 1# 8 G 1-1/2 1# 6 3/4 30.00 20.13 16.00 370 5753 - 200.4 G 4# 250 AL 1# 4 AL G 2 1/2 225.4 G 4# 350 AL , 1# 2 AL G 3 T45 54.1 124.9 70 A 3 P 3# 4 1# 8 G 1-1/4 150 A 3 P 4# 3/0 AL ,1# 4 AL G 2 1# 4 AL 3/4 39.25 26.13 20.00 480 7425 250.4 G 4# 350 AL , 1# 2 AL G 3 I . ■ E T75 90.2 208.2 110 A 3 P 3# 1 ,1# 6 G 1-1/2 250 A 3 P 4# 350 AL ,1# 1/0 AL G 3 1# 1/0 AL 3/4 39.25 30.00 20.00 675 10549 400.4 G 2 [ 4# 250 AL , 1# 1 AL G 2 1/2 1 E T150 180.4 416.4 225 A 3 P 3# 350 AL ,1# 2 AL G 2-1/2 500 A 3 P 2[4# 350 AL ,1# 3/0 AL G 3] 1# 3/0 AL 1 46.63 32.00 27.00 925 16592 800.4 G 3 [ 4# 500 AL , 1# 3/0 AL G 3 1 NOTES: 1.) PRIMARY AND SECONDARY O.C.PROTECTION PER NEC 450.3. 1000.4 G 4 [ 4# 350 AL , 1# 4/0 AL G 3 1 liii 2.) BONDING AND GROUNDING CONDUCTOR PER NEC 250.66. 1200.4 G 4 [ 4# 500 AL , 1# 250 AL G 3 1 ■ 3.) CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. ALUMINUM CONDUCTORS ARE BASED ON TYPE XHHW-2 COMPACT 600V. 2000.4 G 6 [ 4# 600 AL , 1# 400 AL G 3 1/2 1 MIN ■ 4.) SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. 3000.4 G 8 [ 4# 750 AL , 1# 600 AL G 4 1 cr 5.) DIMENSIONS,WEIGHTS&BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. MEC SEE MECH'L EQUIPMENT SCHEDULE ISCA=12,095- -ISCA=1,776(AHU) 6.) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K-RATED TRANSFORMERS. XFMR SEE TRANSFORMER SCHEDULE of 7.) FOR K-RATED TRANSFORMERS,PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS,LOW VOLTAGE PANELBOARD,DISCONNECTS AND/OR LOAD. NOTE: ALUMINUM CONDUCTORS ARE BASED Q 40 11 � ON TYPE XHHW-2 COMPACT 600V ///% I ILRA\ O HRA = 7F _ _ _ _ _ _ � � X XFMR 30 XFMR ��-� P® X ISCA=16,613 -ISCA=1,796 PARI KS H I ROOF ARCHITECTS ISCA=12,126 -ISCA=1,756 ISCA=5,484 2901 E�, ce C08Street,Site 10C -ISCA=1,652 Der1n�' Denver, �� 303.861.855E CH4A/ CCL4A/ CCL4A// QH4A CQL4A/ Consu� tant j XFMR /30 XFMR j jA j KXFMR> ��- ( XFMRA A ISCA=18,484 X -ISCA=1,767 X ISCA=1,914 X ISCA=6,371 ISCA=1,709 FOURTH FLOOR ISCA=6,836 -ISCA=2,917 ISCA=12,544 ISCA=1,780 1V////� ///// / „// / //// CATO R ASSOCIATES , CO . R U M A CH3A C///%% /*/ //L3A / j XFMR %T/ j rucuA j XFMR /T%XFMR/ 45 C i0 896 Tabor Street 420 W.Lincolnway ALakewood,CO 80401 Cheyenne,WY 82001 303.232.6200(P) 307.274.3830(P) X ISCA=7,755 -ISCA=3,057 X ><- ISCA=17,422 -ISCA=1,798 303.233.3701(F) 303.233.3701(F) ISCA=2,469 www.catorruma.com C C THIRD FLOOR CATH1 CATH1 PDU UPS F. „/• ,/Z) TO'CL2C' ISCA= 16,346 X X ISCA=9,775 \"�yy1�l11I I It/rr!!g. 125.3G1) C0.3G1 ) .d• ao ��r41•t yfrt /// //// ISCA=3,200 I// // ', .{ +� _ / //// j//// 'C] 0 CH2A/ CATH1/ C CL2A/ /CL2A/ _ � 41821 gr 7/, r A rj tz) 4 /A // T // A A ISCA= 17,342 X ISCA=5,189 ISCA=3,259 X ISCA=2,759 r/I X ISCA=2,675 rr �s/Oi�A1_ �C:N���`�� V-P0.4r.4:,:otmotit44/7 ti 1'810/1/1111110'�`� CDSECOND FLOOR RENAME %///// PANEL'EL2D' /QL2A TO'QL2A' jIssuance CPERMIT 06/30/17 ISCA= 1,766 X XFMR Revisions ate ISCA= 1,777 X T-EL2D 30 C ISCA=10,882 X C (XFMR) ISCA=7,292 ISCA=1,696 ISCA=9,61 -ISCA=1,741 RENAME ////// / //// / //// ///// //////, / / // PANEL'EH2F' �QH2A/ CH1A/ CL1A� ///// CL1A 2 CL1A/ TO'QH2A' j XFMR )A A 30 XFMR XFMR ) �jX XFMR j 4 A A C ISCA=13,285 X ISCA=9,364 X -ISCA=1,733 X ISCA=11,834 -ISCA=1,771 X ISCA=2,573 FIRST FLOOR / Mk EL U //// vv jA Prop, Information ISCA=7,582 200.4G 100.4G 200.4G 100.4G XFMR 100.4G 100.4G 100.4G 100.4G lir CIO CD CD CD ISCA=7,823 //j , (00A3 /ECJI006A T 150 ��� EC OOA3P OOA3P OOA3P P EC // / // ' • r• • `• • SPACE(XFMR) V 100A3P OOA3P 100A3P 100A3P TSCA=36,814 - `: �• • �• �• • i-de �50A3P / ISCA=4,610 I• /• `• I• TO"ATS-I3-EQ" �i' ��i -__ .. 16UPSA •/ • • • /,/ // /� r '* /Z /% % A' 1La C ISCA=26,827 �� DISTRIBUTION PANEL"QDHBA" 277/480V,3PH,4W 800A 50.4G1 ) 230.3G 225.4G E100.4-G) 100.4G 42,000 AIC i DISTRIBUTION PANEL"UCLBB" 120/208V,3PH,4W 225A 10,000 AIC - - - r- i 1 Z co ,• •S • `• Af., EXTEND EXISTING ISCA-33,196 e // , 225.4G FEEDER FROM PANEL CO j;ry � I (XFMR) lip � CL1B'TO NEW PANEL1 E TO"ATS-12-CR" E 2 O �� 7/ /7 7// jj/ // /7/ /% _A R8ELOCATED XFMR 75 XFMR TO"EC1A" IISCA=2296 l' DISTRIBUTION PANEL"CDHBB" UPS - Ir _ _ _ J Q - 277/480V,3PH,4W 600A '- 35,000 AIC ISCA=5,076- 1 TO I Q I > "EMCC" CO T 100.4G 225.4G 1150.4G1 I _T 2- -0 I / / /� L4LJ CLBA I Z0 0)j C - co c 150.4G X ISCA=5,567 X ISCA=5,056 0 EL-3 ISCA=30,946 -� ISCA=34,497 Q ���^^ 0 0 0 0 MED.AIR VACUUM , vJ W co m rS r> XFMR VACUUM XFMR ATS-10-CR ' ATS-11-EQ UJ EX FAN COMP. PUMP 3 KLVAC) X u HU-1 u u HU-1 aK DI KHCP PUMP 4 �� �/ 0 HOOD#10 T B u 0 D cU) 1 1 X ISCA=5,579 M - 0 X� ISCA=5,147 TO"MDC" 260A3P C' `i 400A3P 150A3P O M • • © © © 0 O OM OM T 75 X ISCA=26,141 " " ' T ISCA=30,946 ISCA=34,497 F X 75 TO"MDC" i p F ISCA=25,028 ISCA= ISCA=5,906 TO"CL3A" ISCA= 13,495 ISCA= 5,906 (MEC) 14,344 80.3G ® ® ® ® (\MEC MEC CD 400.4G2 30.3G ® ® ISCA=20,318 X ////// O O (9 O XFMR CD 050.4) GDCA GDCA MEC MEC MEC MEC MEC MEC MEC ��// / / / P�� SPARE ,• • • • • • • • • • j/ �• �• `• // ,• ///4 `• �•• •15A3P •100A3P • • • • • • • 110A3P 400A3P CA ��• 30A3P `•�5A3P //•• 15A3P 100A Ii, • 70A30 • 10A3P • 110A3P 250A3P , , J'A' _ Z _ /F Z Z # Sheet Information EQUIPMENT BRANCH CRITICAL BRANCH SUB-DISTRIBUTION PANEL"EDHBA" SUB-DISTRIBUTION PANEL"CDHBA" Sheet Title: p 277/480V,3PH,4W,400A BUS 277/480V,3PH,4W,400A BUS p 35,000 AIC 35,000 AIC BASEMENT ELECTRICAL ONE-LINE DIAGRAM - WEST CRITICAL ELECTRICAL ONE-LINE DIAGRAM - WEST CRITICAL AND EQUIPMENT AND EQUIPMENT SCALE:NONE Sheet Ni rri r: 0 C E - 014 . 75 C N r C M DPA Project: 15924.00 CCPYRGHT -DAMS PARTNERS-IP, 1 1 2 3 4 5 E