Loading...
HomeMy WebLinkAboutB17-0340_E-017.75_1507837260.pdf 1 2 3 4 6 6 <0 4, , IV° -14E0113- 10/12/17 'a. ' . I. " � E E I . , ' . • 111 ■ 111 ■ ■ i DAVIS PART NERSHIP ARCH ITECTS 2901 Flare Strep,Slate 10C Darner 1 Denver,CO80205 303.861.855E Consultant 1 CATOR I RUMA & ASSOCIATES , CO . 896 Tabor Street 420 W.Lincolnway Lakewood,CO 80401 Cheyenne,WY 82001 303.232.6200(P) 307.274.3830(P) 303.233.3701(F) 303.233.3701(F) www.catorruma.com C C 4‘N\''. 0.0, L, ,q,�it. i (C+ i ,'0 O I °'11�'; /lffJ(,s,,. a•e•.a T.,,-��yh Issuance PERMIT 06/30/17 TRANSFORMER SCHEDULE Fbvisions ate KEY PRI FLA SEC FLA PRIMARY SECONDARY GEC DIMENSIONS WEIGHT BTUH ' NOTE 480 V 208 V CB SWITCH FUSE CONDUCTORS "C CB SWITCH FUSE CONDUCTORS "C CNDTRS "C HIGH WIDE DEEP OTPT T150 180.4 416.4 225 A 3 P 400 A 3 P FRS-R- 225 3# 4/0 ,1# 4 G 2 500 A 3 P 600 A 3 P FRN-R- 500 2[4# 250 ,1# 1/0 G 2-1/2] 1# 1/0 3/4 46.63 32.00 27.00 925 16592 NOTES: 1.) OVERCURRENT PROTECTION IS SIZED PER NEC 450.3. 2.) ALL CONDUCTORS ARE COPPER. SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP,ETC. 3.) SECONDARY BONDING AND GROUNDING CONDUCTORS ARE SIZED PER NEC 250.66 AND 250.102. C 4.) DIMENSIONS,WEIGHTS&BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. C 5.) FOR K-RATED TRANSFORMERS,PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS,LOW VOLTAGE PANELBOARD,DISCONNECTS AND/OR LOAD. 6.) CONDUIT 40%FILL RATIO IS BASED ON EMT. FEEDER SCHEDULE KEY CONDUCTORS "C TO"MDP" 1000.4 3 I 4# 500 3 1/2 1 ISCA=7700 100.4 G 4# 1 1# 8 G 1 1/2 200.4 G 4# 3/0 1# 6 G 2 1/2 1000.4 G 3 I 4# 500 , 1# 2/0 G 3 1/2 1 XFMR MEC SEE MECH'L EQUIPMENT SCHEDULE TO EXISTING XFMR SEE TRANSFORMER SCHEDULE AMBULANCE BUILDING 0 400A T ISCA=7847 EMON DMON O TO TO AC-2(ON DEMAND METER FCU ROOF) Project Irlifarrr>ation / ISCA=5610 - ISCA=7999 T \-\ISCA=4670 ISCA=4670 150 "TMDS" - / ISCA=25,907 PAD MOUNTED a1000A 277/480V, 3PH, 4W 100.4G ( XFMR) 480/277V XFMR NEMA-3R, 65,000 AIC WITH METERING - BASE ® MECH I I I (2)SPACE ISCA=26,063— LSIG LIME IJSIQG lS LSIG ISCA=33,900 � / 1.0 GFI / GFI , LL • SPD 1000 LSIGZ 1000.4G BUS DUCT 1 1000.46) LSIGZ 100A3P • 25A3P C7 MEC 100A3P I _ XFMR / 200A3P • 200A3P MEC b Z N- 1000A3P NEMA-3R 1000A3P Li ISCA=32,036— - - • 0 LSIG LSIG LISG CO0 E #3/0G "NDH2A" E 2 0 = = #3/OG 1000A 277/480V, 3PH,4W Q _. COLD BLDG. 200.4G 200.4G ® 65,000 AIC WATER STEEL Q PIPE COLD BLDG. WATER STEEL PIPE LEVEL TWO ISCA=21,546 ISCA=20,919 ISCA=2351 0 2 Ti fl TO GE TO CT TO CRAC-2(1ST 3 CD XRAY SCANNER FLR CT) 0 LEVEL ONE _i_d F co O Q W 0 CO r CENTRAL ENABLING ONE-LINE DIAGRAM - NORMAL POWER - NEW SCALE:NONE Sheet InforrrElfion A A Sheet Title: ELECTRICAL ONE-LINE DIAGRAM - EAST TEMPORARY SERVICE Shy Nirri:er: 2 E . 0 1 7 7 5 7 . 75 0_O N r-- E, CPA Project: 15924.00 CCPYR1GHT -DAMS PPR1IaiSHP, 1 2 3 4 5 6