Loading...
HomeMy WebLinkAboutB17-0340_E-017.75_1507837301.pdfT M SPD ~ ~ M F E E D E R S C H E D U L E KEY CONDUCTORS "C 1000.4 3 [ 4 # 500 3 1/2 ] 100.4 G 4 # 1 , 1 # 8 G 1 1/2 200.4 G 4 # 3/0 , 1 # 6 G 2 1/2 1000.4 G 3 [ 4 # 500 , 1 # 2/0 G 3 1/2 ] MEC SEE MECH'L EQUIPMENT SCHEDULE XFMR SEE TRANSFORMER SCHEDULE T R A N S F O R M E R S C H E D U L E KEY PRI FLA SEC FLA PRIMARY SECONDARY GEC DIMENSIONS WEIGHT BTUH NOTE 480 V 208 V CB SWITCH FUSE CONDUCTORS "C CB SWITCH FUSE CONDUCTORS "C CNDTRS "C HIGH WIDE DEEP OTPT T150 180.4 416.4 225 A 3 P 400 A 3 P FRS-R- 225 3 # 4/0 , 1 # 4 G 2 500 A 3 P 600 A 3 P FRN-R- 500 2 [ 4 # 250 , 1 # 1/0 G 2-1/2 ] 1 # 1/0 3/4 46.63 32.00 27.00 925 16592 NOTES: 1.) OVERCURRENT PROTECTION IS SIZED PER NEC 450.3. 2.) ALL CONDUCTORS ARE COPPER. SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP, ETC. 3.) SECONDARY BONDING AND GROUNDING CONDUCTORS ARE SIZED PER NEC 250.66 AND 250.102. 4.) DIMENSIONS, WEIGHTS & BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. 5.) FOR K-RATED TRANSFORMERS, PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS, LOW VOLTAGE PANELBOARD, DISCONNECTS AND/OR LOAD. 6.) CONDUIT 40% FILL RATIO IS BASED ON EMT. CENTRAL ENABLING ONE-LINE DIAGRAM - NORMAL POWER - NEW "NDH2A" BASE WITH METERING 480/277V XFMR PAD MOUNTED 1000A3P 400A 1000A3P "TMDS" COLD WATER PIPE BLDG. STEEL #3/0G G N COLD WATER PIPE BLDG. STEEL #3/0G G N (2) SPACE TO AC-2 (ON ROOF) TO CRAC-2 (1ST FLR CT) ISCA=33,900 ISCA=32,036 ISCA=26,063 ISCA=5610 ISCA=7847 ISCA=7999 ISCA=25,907 ISCA=4670 ISCA=4670 ISCA=2351 ISCA=20,919 ISCA=21,546 ISCA=7700 NONE SCALE: 1000A 277/480V, 3PH, 4W LSIG XFMR LSIG 200A3P LSIG 200A3P LSIG 100A3P LSIG 150 GFI GFI GFI GFI GFI GFI XFMR XFMR 1000A 277/480V, 3PH, 4W LSIGZ GFI 1000.4 1000.4G 1000.4G BUS DUCT J LSIGZ 65,000 AIC NEMA-3R, 65,000 AIC NEMA-3R LSIG 25A3P 100.4G LSIGLSIG MEC GFI LSIGLSIG 100A3P GFI MECH MECH LSIGLSIG MEC MECH GFI 200.4G 200.4G XFMR LEVEL TWO LEVEL ONE TO "MDP" TO GE XRAY TO CT SCANNER TO EXISTING AMBULANCE BUILDING EMON DMON DEMAND METER TO FCU #2 CT 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 2:16:09 PM 15924.00 E-017.75 ELECTRICAL ONE-LINE DIAGRAM - EAST TEMPORARY SERVICE 06/30/17 PERMIT EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657 10/12/17