Loading...
HomeMy WebLinkAboutB17-0340_E-302.75_1507837307.pdf2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant 6/30/2017 2:17:11 PM 15924.00 E-302.75 ELECTRICAL PANEL SCHEDULES 06/29/17 PERMIT EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657 General Notes: O Other 0 VA 0.00% 0 VA E Existing 0 VA 0.00% 0 VA Total Demand Current: 42 A K Kitchen 0 VA 0.00% 0 VA Total Demand Load: 15180 VA G General 3260 VA 100.00% 3260 VA C Continuous 0 VA 0.00% 0 VA Total Connected Current: 43 A M Motor 0 VA 0.00% 0 VA Total Connected Load: 15600 VA R Receptacle 11340 VA 94.09% 10670 VA L Lighting 1000 VA 125.00% 1250 VA Power Factor: 1 Load Type Connected Load Demand Factor Demand Load Panel Totals Phase Balance: 19 % A-B 9 % B-C 30 % C-A Total Amps: 50 A 42 A 39 A Total Load: 5960 VA 5000 VA 4640 VA 41 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 42 39 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 40 37 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 38 35 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 36 33 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 34 1 31 R-CT HALL BATH R 20 A 1 180 VA 0 VA 1 20 A -- Spare 32 1 29 R-S.H. VISUAL OFFICE R 20 A 1 900 VA 0 VA 1 20 A -- Spare 30 1 27 R-CT R 20 A 1 1080 VA 0 VA 1 20 A -- Spare 28 1 25 L-CT L 20 A 1 250 VA 0 VA 1 20 A -- Spare 26 1 23 L-CT L 20 A 1 250 VA 0 VA 1 20 A -- Spare 24 21 500 VA 0 VA 1 20 A -- Spare 22 1 19 SYSCO SWITCH ED TELE G 20 A 2 500 VA 0 VA 1 20 A -- Spare 20 1 17 R-CT R 20 A 1 1080 VA 0 VA 1 20 A -- Spare 18 1 15 R-CT R 20 A 1 1080 VA 0 VA 1 20 A -- Spare 16 1 13 L-DR. LOUNGE L 20 A 1 250 VA 200 VA 1 20 A G R-NUC. MED - PRINTER 14 1 11 L-STORAGE L 20 A 1 250 VA 540 VA 1 20 A R R-NUC. MED - CONTROL 12 9 R-OFFICE R 20 A 1 720 VA 180 VA 1 20 A G R-NUC. MED - COMP. 10 7 R-OFFICE R; G 20 A 1 1280 VA 1680 VA 1 20 A G R-NUC. MED - MICRO 8 5 R-OFFICE R 20 A 1 720 VA 900 VA 1 20 A R R-NUC. MED - HOT LAB 6 3 R-OFFICE R 20 A 1 720 VA 720 VA 1 20 A R R-NUC. MED 4 1 R-OFFICE R 20 A 1 720 VA 900 VA 1 20 A R R-NUC. MED 2 Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note 1. REFED FROM PANEL 'PB' Circuit Notes: Enclosure: Type 1 Mounting: Surface Wire: 4 Bus Rating: 100 A Supply From: L1E Phase: 3 Mains Type: MLO Location: Voltage: 120/208 Wye A.I.C. Rating: 10,000 Panel NL1D EXISTING O Other 0 VA 0.00% 0 VA E Existing 0 VA 0.00% 0 VA Total Demand Current: 122 A K Kitchen 4320 VA 90.00% 3888 VA Total Demand Load: 44033 VA G General 7360 VA 100.00% 7360 VA C Continuous 0 VA 0.00% 0 VA Total Connected Current: 173 A M Motor 624 VA 125.00% 780 VA Total Connected Load: 62504 VA R Receptacle 47660 VA 60.49% 28830 VA L Lighting 2540 VA 125.00% 3175 VA Power Factor: 1 Load Type Connected Load Demand Factor Demand Load Panel Totals Phase Balance: 20 % A-B 17 % B-C 2 % C-A Total Amps: 188 A 157 A 184 A Total Load: 22120 VA 18780 VA 21604 VA 83 HEAT TAPE OB GUTTER -- 20 A 1 0 VA 0 VA 1 20 A -- HEAT TAPE OB GUTTER 84 81 HEAT TAPE OB GUTTER -- 20 A 1 0 VA 0 VA 1 20 A -- HEAT TAPE OB GUTTER 82 1 79 FA EXTENDER G 20 A 1 200 VA 0 VA 1 20 A -- Spare 80 1 77 CAMERA POWER R 20 A 1 180 VA 180 VA 1 20 A R L-111,112,113 78 1 1 75 RAY DAMPERS G 20 A 1 200 VA 360 VA 1 20 A R R-SERVER RM 113 76 1 73 Spare -- 20 A 1 0 VA 1080 VA 1 20 A R R-SERV RM 111,112,113 74 1 71 4640 VA 0 VA 1 20 A -- Spare 72 69 5000 VA 500 VA 1 20 A R R-CARDIO STRESS... 70 1 2 67 NEW PANEL 'NL1D' R; G; L 100 A 3 5960 VA 0 VA 1 20 A -- Spare 68 2 65 R-OFFICE R 20 A 1 1260 VA 360 VA 1 20 A R R-PT TREADMILL 66 1 1 63 R-BREAK ROOM DISP K 20 A 1 1620 VA 300 VA 1 20 A G R-CARDIO TECH WORK 64 1 61 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 62 1 59 PRE-ACTION COMP. M 20 A 1 624 VA 0 VA 1 20 A -- Spare 60 2 57 R-OFFICE R 20 A 1 900 VA 0 VA 1 20 A -- Spare 58 1 55 R-MRI CONTROL ROOM R 20 A 1 900 VA 360 VA 1 20 A R R-STORAGE 56 2 2 53 R-OFFICE COPIER G 20 A 1 1000 VA 540 VA 1 20 A R R-STORAGE 54 2 2 51 R-OFFICE R 20 A 1 1080 VA 720 VA 1 20 A R R-CARDIO CLEAN CHG 52 1 2 49 R-OFFICE R 20 A 1 1260 VA 720 VA 1 20 A R R-CARDIO CLEAN CHG 50 1 2 47 R-OFFICE R 20 A 1 540 VA 1080 VA 1 20 A R R-CARDIO TECH WORK 48 1 1 45 R-BREAK ROOM R 20 A 1 540 VA 540 VA 1 20 A R R-CARDIO CORRIDOR 46 1 1 43 R-BRK MICROWAVE K 20 A 1 1500 VA 360 VA 1 20 A R R-CARDIO ABG ROOM 44 1 1 41 R-BRK REF K 20 A 1 1200 VA 720 VA 1 20 A R R-CARDIO RECEPTION 42 1 1 39 MAG DOOR HOLDERS G 20 A 1 0 VA 360 VA 1 20 A R R-CORR/STAFF RECESS 40 2 1 37 R-SHF WORK ROOM R 20 A 1 540 VA 0 VA 1 20 A -- Spare 38 1 35 R-SHF OFFICE NORTH R 20 A 1 360 VA 540 VA 1 20 A R R-CARDIO OFFICE 36 1 2 33 R-CONF ROOM - A/V R 20 A 1 360 VA 540 VA 1 20 A R R-ULTRASOUND 34 2 2 31 R-COPIER G 20 A 1 1000 VA 180 VA 1 20 A R R-CARDIO CONTROL RR 32 1 2 29 R-OFFICE/COPY R 20 A 1 540 VA 360 VA 1 20 A R CARDIO CNTL CHG 30 1 1 27 R-PRE-OP CHECK IN R 20 A 1 720 VA 360 VA 1 20 A R CARDIO CNTL CHG 28 1 1 25 R-PRE-OP CHECK IN R 20 A 1 720 VA 0 VA 1 20 A -- Spare 26 1 23 R-MRI MECH ROOM R 20 A 1 1080 VA 0 VA 1 20 A -- Spare 24 1 21 R-SHF CORRDIOR R 20 A 1 900 VA 720 VA 1 20 A R R-STORAGE 22 2 2 19 R-CONFERENCE ROOM R; G 20 A 1 560 VA 1440 VA 1 20 A R R-CARDIO CONTROL 20 1 1 17 R-SHF OFFICES R 20 A 1 900 VA 1080 VA 1 20 A R R-OFFICE 18 2 15 0 VA 900 VA 1 20 A R R-OFFICE 16 2 1 13 PANEL 'MRI' R; G 50 A 2 1360 VA 920 VA 1 20 A R; G R-SHF BIOMECH... 14 1 1 11 L-MRI L 20 A 1 1540 VA 900 VA 1 20 A R R-OFFICE 12 2 1 9 R-SHF OFFICES R 20 A 1 900 VA 180 VA 1 20 A R R-SHF BIOMECH... 10 1 1 7 R-SHF OFFICES R 20 A 1 720 VA 720 VA 1 20 A R R-SHF OFFICES 8 1 1 5 R-SHF OFFICE, VISITOR R 20 A 1 1440 VA 540 VA 1 20 A R R-SHF OFFICES 6 1 1 3 R-SHF OFFICE, RR R 20 A 1 540 VA 540 VA 1 20 A R R-SHF OFFICES 4 1 1 1 R-SHF RECEPTION R 20 A 1 540 VA 1080 VA 1 20 A R R-OFFICE 2 2 Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note 1. EXISTING LOAD 2. NEW LOAD Circuit Notes: Enclosure: Type 1 MCB Rating: 200 A Mounting: Surface Wire: 4 Bus Rating: 200 A Supply From: Phase: 3 Mains Type: MLO Location: Voltage: 120/208 Wye A.I.C. Rating: 10,000 Panel L1E EXISTING General Notes: O Other 0 VA 0.00% 0 VA E Existing 0 VA 0.00% 0 VA Total Demand Current: 0 A K Kitchen 0 VA 0.00% 0 VA Total Demand Load: 0 VA G General 0 VA 0.00% 0 VA C Continuous 0 VA 0.00% 0 VA Total Connected Current: 0 A M Motor 0 VA 0.00% 0 VA Total Connected Load: 0 VA R Receptacle 0 VA 0.00% 0 VA L Lighting 0 VA 0.00% 0 VA Power Factor: Load Type Connected Load Demand Factor Demand Load Switchboard Totals % A-B % B-C % C-A Refer to one-line diagram for space, spare, and circuit breaker quantities. 0 A 0 A 0 A 0 VA 0 VA 0 VA Load Type A B C Note 1. EXISTING LOAD 2. REFED FROM 'DHA' Circuit Notes: MCB Rating: 1000 A Mounting: Wires: 4 Bus Rating: 1000 A Supply From: Phases: 3 Mains Type: MCB Location: Volts: 120/208 Wye A.I.C. Rating: 35,000 Switchboard MDP 10/12/17