Loading...
HomeMy WebLinkAboutB17-0340_G-001-2_1507837306.pdfPROJECT FRONTAGE RD. W. MEADOWS LIONSHEAD CIR VAIL RD BEAVER DAM FOREST ROCKLEDGE MIL L CREEK R D MILL C R EEK RD LIFT 8 I-70 1. THE CONTRACT DOCUMENTS IN THEIR ENTIRETY ARE THE RESPONSIBILITY OF ALL TRADES. WHERE REQUIREMENTS ARE SHOWN IN ONE SECTION OF THE SPECIFICATIONS OR DRAWINGS BUT NOT ANOTHER, THE CONTRACTOR OR SUBCONTRACTOR IS NOT RELIEVED FROM PROVIDING COMPLETELY FINISHED AND PROPERLY FUNCTIONING SYSTEMS. 2. THE CONTRACTOR / SUBCONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LAYOUT AND COORDINATION OF DIMENSIONS IN THE FIELD THAT ESTABLISH WORK POINTS FOR THEIR WORK AND VARIOUS TRADES. 3. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR THE PROPER EXECUTION, INSTALLATION, OR PERFORMANCE OF THE WORK, SHALL BE PROVIDED BY THE CONTRACTOR / SUBCONTRACTOR. 4. ALL ITEMS REQUIRING A METHOD OF PROCEDURE APPROVAL SHALL BE SUBMITTED FOR REVIEW 21 DAY IN ADVANCE. 5. THE CONSTRUCTION SITE IS TO BE KEPT CLEAN AND FREE OF DEBRIS. THE CONTRACTOR / SUBCONTRACTOR IS RESPONSIBLE FOR ALL PHASES OF SECURING, HANDLING, TRANSPORTING AND DISPOSING OF DEBRIS. 6. THE CONTRACTORS / SUBCONTRACTORS SHALL NOT SHUT OFF OR INTERRUPT ANY SYSTEMS OR SERVICES WITHOUT FIRST COORDINATING WITH THE OWNER. 7. THE CONTRACTOR / SUBCONTRACTORS SHALL COORDINATE WITH THE OWNER TO IDENTIFY AND PROTECT EXISTING STRUCTURE, ELECTRICAL/DATA/TELECOM SYSTEMS, UTILITIES, SURFACES AND FINISHES WHICH ARE TO REMAIN. ANY DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED BY THE CONTRACTOR/SUBCONTRACTOR. 8. DELIVERY AND STORAGE OF CONSTRUCTION MATERIALS AND EQUIPMENT (STAGING AREAS) SHALL BE COORDINATED WITH THE OWNER. NOT TO INTERFERE WITH HOSPITAL TRAFFIC. 9. THE CONTRACTOR / SUBCONTRACTOR SHALL TAKE CARE TO PROTECT ALL NEWLY INSTALLED MATERIALS AND FINISHES UNTIL WORK IS FORMALLY ACCEPTED BY THE ARCHITECT OR THE OWNER'S REPRESENTATIVE AND TRANSFERRED TO THE OWNER 10. ALL PENETRATIONS THROUGH FLOORS, WALLS AND RATED ASSEMBLIES AS WELL AS ALONG SLAB PERIMETERS AND SEPARATION WALL PERIMETERS, SHALL BE SEALED AND PROTECTED WITH U.L. APPROVED SAFETY ASSEMBLIES AND/OR PROTECTIVE DEVICES HAVING THE SAME OR GREATER TESTED RATING AS THAT REQUIRED FOR THE ASSEMBLY BEING PENETRATED. ALL PENETRATIONS SHALL BE PROTECTED TO MAINTAIN FIRE RATED ASSEMBLY INTEGRITY. 11. PROVIDE ELECTROLYTIC PROTECTION / ISOLATION BETWEEN ALL DISSIMILAR METALS, AND BETWEEN TREATED WOOD AND METALS TO PREVENT ELECTROLYTIC REACTION AND/OR CORROSION. 12. ALL WOOD, EXCEPT ARCHITECTURAL WOODWORK, USED ON THIS PROJECT SHALL BE FIRE RETARDANT, NON-COMBUSTIBLE TREATED AS APPROVED FOR USE BY THE LOCAL CODE AUTHORITIES. NO WOOD (WHETHER TREATED OR NOT) SHALL BE USED WITHIN THE CEILING PLENUM SPACE. 13. THE CONTRACTOR / SUBCONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING, BACKING OR STRUCTURAL SUPPORT AS REQUIRED TO PROPERLY INSTALL ALL MOUNTED ASSEMBLIES, INCLUDING ALL ATTACHED EQUIPMENT (OWNER AND CONTRACTOR FURNISHED ITEMS), PLUMBING FIXTURES, MILLWORK, AND CASEWORK. NOTE: ALL FRAMING OR CONCEALED BLOCKING SHALL BE METAL BETWEEN STUDS AS IS RECOMMMENDED FOR WALL MOUNTED ITEMS. REFER TO THE A-700 SERIES DRAWINGS FOR FUTHER INFORMATION. 14. WHERE FIRE EXTINGUISHER CABINETS, ELECTRICAL PANELS OR OTHER EQUIPMENT OR DEVICES ARE RECESSED IN FIRE-RATED PARTITIONING AND/OR SOUND RATED PARTITIONING, MODIFY PARTITION CONSTRUCTION TO PROVIDE CONTINUOUS ENCLOSURE FOR UNINTERRUPTED ASSOCIATED FIRE RATING AND/OR SOUND RATING. 15. ALL ROOMS OR AREAS WITH CEILINGS OPEN TO STRUCTURE ARE TO HAVE METAL WALL GRILLS FOR AIR DUCT OPENINGS OR AT OPEN AIR TRANSFERS. COORDINATE SIZE OF GRILLE WITH MECHANICAL DRAWINGS AND AIR FLOW REQUIREMENTS. 16. METAL FRAMING STUD SPACING MAY VARY AT LOCATIONS RECEIVING MOISTURE RESISTANT GYPSUM BOARD. INSTALL FRAMING AT WALLS, HARD CEILINGS AND SOFFITS PER MANUFACTURER'S RECOMMENDATIONS. REFER TO SPECIFICATIONS FOR A DISCRIPTION OF THE LOCATIONS TO RECEIVE MOISTURE RESISTANT GYPSUM BOARD INCLUDING BUT NOT LIMITED TO LOCATIONS ADJACENT TO PLUMBING FIXTURES. 17. THE GC SHALL CARRY FIRE WATCH COSTS TO PROVIDE PERSONNEL PER NFPA. 18. THE OWNER WILL BE REQUIRED TO SIGN OFF ON ROUGH IN AND ARCHITECTURAL DEVICES BEFORE PROCEEDING. SEE SPECIFICATION 01 4000 FOR MORE INFORMATION. 19. GC TO PROVIDE ICRA COMPLIANCE PLAN TO OWNER FOR APPROVAL PRIOR TO COMMENCING WORK. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, Sheet Title: Sheet Information Project Information Location Project Sheet General EAST WING ENABLING Revisions Date Project Information Issuance Consultant 6/30/2017 11:48:17 PM 15924.00 G-001-2 VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 SHEET INDEX AND PROJECT DATA ARCHITECT Davis Partnership Architects 2901 Blake Street Suite 100 Denver, CO 80205 P. 303.861.8555 Ann Adams ann.adams@davispartnership.com OWNER Vail Valley Medical Center 180 S Frontage Road W Vail, CO 81657 Helen Rowe helen.rowe@vvmc.com CIVIL ENGINEER Martin/Martin, Inc. 0101 Fawcett Rd. Suite 260 Avon, Co 81620 P. 970.926.6007 Mark Luna mluna@martinmartin-mtn.com OWNER REPRESENTATIVE Project One Integrated Services 88 Inverness Cir E Building G, Suite 101 Englewood, CO 80112 P. 303.917.7507 Chris Knight chrisk@projectoneis.com MECHANICAL, ELECTRICAL, PLUMBING Cator Ruma & Associates Co 896 Tabor Street Lakewood, CO 80401 P. 303.232.6200 Wayne Trader wtrader@catorruma.com CODE CONSULATANT Advanced Consulting Engineers 3900 S. Wadsworth Blvd. Suite 595 Lakewood, CO 80235 P. 720.981.4150 Masoud Sabounchi masoud@acecode.com STRUCTURAL ENGINEER Martin/Martin, Inc. 12499 W. Colfax Ave. Lakewood, CO 802015 P. 303.431.6100 Shane McCormick smccormick@martinmartin.com MEDICAL EQUIPMENT Mitchell Associates 630 Dundee RD Suite 340 Northbrook, IL 60062 360.798.7653 Matt Gibbs mgibbs@mitchellplanning.com INTERIOR DESIGNER Davis Partnership Architects 2901 Blake Street Suite 100 Denver, CO 80205 P. 303.861.8555 Janette Ray janette.ray@davispartnership.com 2017 06/30/17 PERMIT NUMBER SHEET ISSUANCE ISSUE DATE REVISION NAME REVISION DATE 01 General G-001-1 COVER PERMIT 06/30/17 G-001-2 SHEET INDEX AND PROJECT DATA PERMIT 06/30/17 02 Life Safety LS000-1 CODE ANALYSIS PERMIT 06/30/17 LS101-1 LIFE SAFETY PLAN - LEVEL 1 PERMIT 06/30/17 LS101-2 LIFE SAFETY PLAN - LEVEL 1 - OCCUPANCY & USE PERMIT 06/30/17 LS201A-1 INTERIM LIFE SAFETY PLAN - AREA A-SEQ 1 PERMIT 06/30/17 LS201A-2 INTERIM LIFE SAFETY PLAN - AREA A-SEQ 2 PERMIT 06/30/17 LS201A-3 INTERIM LIFE SAFETY PLAN - AREA A-SEQ 3 PERMIT 06/30/17 03 Civil C010 GENERAL NOTES PERMIT 06/30/17 C110 EXISTING CONDITIONS PLAN PERMIT 06/30/17 C111 EXISTING CONDITIONS PLAN PERMIT 06/30/17 C120 DEMOLITION PLAN PERMIT 06/30/17 C121 DEMOLITION PLAN PERMIT 06/30/17 C122 DEMOLITION PLAN PERMIT 06/30/17 C123 O2 ENCLOSURE DEMOLITION PLAN PERMIT 06/30/17 C130 EROSION CONTROL PLAN PERMIT 06/30/17 C200 SITE LAYOUT AND RECONSTRUCTION PLAN PERMIT 06/30/17 C201 SITE LAYOUT AND RECONSTRUCTION PLAN PERMIT 06/30/17 C202 SITE LAYOUT AND RECONSTRUCTION PLAN PERMIT 06/30/17 C203 O2 ENCLOSURE SITE LAYOUT PERMIT 06/30/17 C210 SOUTH GRADING PLAN PERMIT 06/30/17 C211 WEST GRADING PLAN PERMIT 06/30/17 C212 INTERIM GRADING PLAN PERMIT 06/30/17 C213 OXYGEN BUNKER GRADING PLAN PERMIT 06/30/17 C300 UTILITY PLAN PERMIT 06/30/17 C301 UTILITY PLAN PERMIT 06/30/17 C320 SANITARY SEWER MAIN PLAN AND PROFILE PERMIT 06/30/17 C322 SANITARY SEWER MAIN PLAN AND PROFILE PERMIT 06/30/17 C330 WATER MAIN & SERVICE PLAN PROFILE PERMIT 06/30/17 C400 EROSION CONTROL DETAILS PERMIT 06/30/17 C401 EROSION CONTROL DETAILS PERMIT 06/30/17 C403 EROSION CONTROL DETAILS PERMIT 06/30/17 05 Landscape L-000 ABBREVIATIONS AND SYMBOLS PERMIT 06/30/17 L-100 PHASE 1 SITE MATERIALS AND LAYOUT PLAN PERMIT 06/30/17 L-150 PLANTING PLAN PERMIT 06/30/17 L-500 SITE DETAILS PERMIT 06/30/17 L-550 PLANTING DETAILS PERMIT 06/30/17 06 Structural S-001-1 GENERAL NOTES PERMIT 06/30/17 S-001-2 GENERAL NOTES PERMIT 06/30/17 S-002-1 QUALITY ASSURANCE PERMIT 06/30/17 S-002-2 QUALITY ASSURANCE PERMIT 06/30/17 S-101-B LEVEL 1 - RAMP PLAN PERMIT 06/30/17 S-101-C LEVEL 1 - AMBULANCE BARN PLAN PERMIT 06/30/17 S-101-D LEVEL 1 - OXYGEN ENCLOSURE PLANS PERMIT 06/30/17 S-103-A LEVEL 3 - ED ROOF PLAN PERMIT 06/30/17 S-200-1 CONCRETE DETAILS PERMIT 06/30/17 S-201-1 MASONRY AND LIGHT GAUGE DETAILS PERMIT 06/30/17 S-202-A ED ROOF DETAILS PERMIT 06/30/17 S-203-B RAMP DETAILS PERMIT 06/30/17 S-204-D O2 ENCLOSURE DETAILS PERMIT 06/30/17 08 Architectural Demolition A-000-1 ABBREVIATIONS & SYMBOLS PERMIT 06/30/17 AD101A-1 ENLARGED DEMOLITION FLOOR PLAN - AREA A PERMIT 06/30/17 AD151A-1 ENLARGED DEMOLITION REFLECTED CEILING PLAN - AREA A PERMIT 06/30/17 09 Architectural A-101-0 OVERALL SITE PLAN PERMIT 06/30/17 A-101-1 OVERALL FLOOR PLAN - LEVEL 1 PERMIT 06/30/17 A-101A-1 ENLARGED ANNOTATION AND DIMENSION FLOOR PLAN - AREA A PERMIT 06/30/17 A-101B-1 ENLARGED ANNOTATION AND DIMENSION FLOOR PLAN - AREA B PERMIT 06/30/17 A-101C-1 ENLARGED ANNOTATION AND DIMENSION FLOOR PLAN - AREA C PERMIT 06/30/17 A-101D-1 ENLARGED ANNOTATION AND DIMENSION FLOOR PLAN - AREA D PERMIT 06/30/17 A-107-1 OVERALL FLOOR PLAN - ROOF PERMIT 06/30/17 A-151-1 OVERALL REFLECTED CEILING PLAN - LEVEL 1 PERMIT 06/30/17 A-151A-1 ENLARGED REFLECTED CEILING PLAN - LEVEL 1 - AREA A & B PERMIT 06/30/17 A-200B-1 EXTERIOR ELEVATIONS AND PERSPECTIVES - FUEL TANK AND RAMP PERMIT 06/30/17 A-200D-1 EXTERIOR ELEVATIONS AND PERSPECTIVES - O2 ENCLOSURE PERMIT 06/30/17 A-310-1 WALL SECTIONS AND PERSPECTIVES PERMIT 06/30/17 A-510-1 EXTERIOR DETAILS PERMIT 06/30/17 A-511-1 EXTERIOR DETAILS PERMIT 06/30/17 A-512-1 EXTERIOR DETAILS PERMIT 06/30/17 A-720-1 DOOR SCHEDULE, PARTITION TYPES, AND DETAILS PERMIT 06/30/17 A-720-2 EXTERIOR BUILDING SYSTEMS PERMIT 06/30/17 A-721-1 FRAMING DETAILS PERMIT 06/30/17 14 Mechanical Demolition MD-107-75 ROOF MECHANICAL DEMO PLAN - ENABLING PERMIT 06/30/17 15 Mechanical M-001-75 MECHANICAL LEGENDS & NOTES PERMIT 06/30/17 M-002-75 MECHANICAL SCHEDULES AND DETAILS PERMIT 06/30/17 M-090-75 O2 ENCLOSURE MECHANICAL SITE PLAN PERMIT 06/30/17 M-100-75 MECHANICAL-PLUMBING SITE PLAN - ENABLING PERMIT 06/30/17 M-101-75 LEVEL 1 HVAC AND PIPING PLANS - ENABLING PERMIT 06/30/17 M-102-75 LEVEL 2 HVAC AND HVAC DEMO PLAN - EAST WING ENABLING PERMIT 06/30/17 M-103-75 FUEL OIL TANK PLAN DETAIL AND SCHEDULE PERMIT 06/30/17 M-107-75 ROOF MECHANICAL PLAN - ENABLING PERMIT 06/30/17 16 Electrical Demolition ED-111-75 LEVEL 1 POWER DEMOLITION PLAN PERMIT 06/30/17 ED-112-75 LEVEL 2 POWER DEMOLITION PLAN PERMIT 06/30/17 ED-113-75 ROOF DEMO POWER PLAN - ENABLING PERMIT 06/30/17 17 Electrical E-001-75 ELECTRICAL LEGENDS & NOTES PERMIT 06/30/17 E-011-75 ELECTRICAL ONE-LINE DIAGRAM - WEST NORMAL ENTRANCE PERMIT 06/30/17 E-012-75 ELECTRICAL ONE-LINE DIAGRAM - WEST NORMAL POWER PERMIT 06/30/17 E-013-75 ELECTRICAL ONE-LINE DIAGRAM - WEST EMERGENCY POWER PERMIT 06/30/17 E-014-75 ELECTRICAL ONE-LINE DIAGRAM - WEST CRITICAL AND EQUIPMENT PERMIT 06/30/17 E-015-75 ELECTRICAL ONE-LINE DIAGRAM - EAST NORMAL POWER PERMIT 06/30/17 E-016-75 ELECTRICAL ONE-LINE DIAGRAM - EAST EMERGENCY POWER PERMIT 06/30/17 E-017-75 ELECTRICAL ONE-LINE DIAGRAM - EAST TEMPORARY SERVICE PERMIT 06/30/17 E-100-75 ELECTRICAL SITE PLAN - ENABLING PERMIT 06/30/17 E-111-75 LEVEL 1 POWER PLAN - ENABLING PERMIT 06/30/17 E-112-75 LEVEL 2 POWER PLAN - ENABLING PERMIT 06/30/17 E-113-75 LEVEL 3 POWER PLAN - ENABLING PERMIT 06/30/17 E-114-75 ROOF POWER PLAN - ENABLING PERMIT 06/30/17 E-301-75 ELECTRICAL PANEL SCHEDULES PERMIT 06/30/17 E-302-75 ELECTRICAL PANEL SCHEDULES PERMIT 06/30/17 10/12/17