B17-0340_M-001.75_1507837260.pdf
1 2 3 4 5 6QPVM OF 1/4/ I Aro) 10/12/17 HVAC LEGEND GENERAL LEGEND HVAC PLAN NOTES: GENERAL NOTES: (Not all symbols listed below are used on these drawings) (Not all symbols listed below are used on these drawings) ABBR. SYMBOL 1. DESCRIPTION ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION 1. DUCT SIZE OF BRANCH DUCT TO AIR DEVICE SHALL BE THE SAME SIZE AS 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING NECK SIZE OF AIR DEVICE UNLESS NOTED OTHERWISE. CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. HWS -HWS- HOT WATER SUPPLY PIPING Ain SUPPLY DUCT UP/SUPPLY DUCT DOWN SECTION DESIGNATION DETAIL SHEET 5 PLAN SHEETS I ■■ . . 2. UNLESS OTHERWISE NOTED,ALL SUPPLY AIR DUCTWORK SHALL BE 2. A DETAILED METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION HWR --HWR-- 2.HOT WATER RETURN PIPING Fri AM RETURN DUCT UP/RETURN DUCT DOWN in ,-- DRAWN ON THIS SHEET > > CAP END OF PIPE EXTERNALLY WRAPPED TO THICKNESS AS STATED IN SPECIFICATIONS. ACTIVITY AFFECTS THE SAFETY OF THE OCCUPANTS, OWNER'S EQUIPMENT X � HTWS -HTWS 3.HIGH TEMPERATURE HOT WATER SUPPLY PIPING JII}�1 EXHAUST DUCT UP/EXHAUST DUCT DOWN SECTION CUT ON THIS SHEET XX XX PITCH DOWN IN DIRECTION OF ARROW RETURN AND EXHAUST DUCTWORK IS NEITHER LINED NOR WRAPPED. OR VALUABLE CONTENTS OR ANY SYSTEM WHICH SUPPORTS THESE WI 111 - 3. SYSTEMS;OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, E HTWR --HTWR-- HIGH TEMPERATURE HOT WATER RETURN PIPING ROUND DUCT UP/ROUND DUCT DOWN ©----- RISER DIAGRAM NUMBER >< >< PIPE ANCHOR PROVIDE ROOM AIR BALANCE TO ACHIEVE POSITIVE (+)OR NEGATIVE (-)AT OPERATIONS OR SECURITY. E IU • ■ CWS -CWS- 4,CHILLED WATER SUPPLY PIPING 48F12 INDICATES FLAT OVAL DUCTWORK ® THE DIFFERENTIAL PRESSURE INDICATED ON THE DRAWINGS.SHEET RISER IS DRAWN ON PIPE ALIGNMENT GUIDE 3. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CWR --CWR-- CHILLED WATER RETURN PIPING 1111 i FLEXIBLE DUCT CONNECTIONAftj EQUIPMENT UNIT IDENTIFICATION 1111 UNION OR FLANGE 4. PROVIDE MANUAL VOLUME DAMPER FOR ALL AIR DEVICES. SPIN-IN DAMPERS CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK AND SHALL NOTIFY MIME ARE REQUIRED FOR LOW PRESSURE SUPPLY TAKEOFFS. REFER TO DETAILS. THE ENGINEER/ARCHITECT OF ANY DISCREPANCIES FOR RESOLUTION. D - D - COOLING COIL DRAIN PAN PIPING BDD BACKDRAFT DAMPER Q"."---- EQUIPMENT UNIT NUMBER f -FI- CONCENTRIC PIPE REDUCER III II III ■111 4. COORDINATE WORK WITH ALL TRADES. C - C - CONDENSER WATER SUPPLY PIPING TCD vw\l TEMP.CONTROL DAMPER-OPPOSED BLADE DIFFUSER IDENTIFICATION ECCENTRIC PIPE REDUCER © CF K�� DIFFUSER NECK DIAMETER 5. CONTRACTOR IS RESPONSIBLE FOR SECURING AND WEATHERPROOFING ANY CR -- CR -- CONDENSER WATER RETURN PIPING TCD I\.\v TEMP.CONTROL DAMPER-PARELLEL BLADE M•� DIFFUSER CFM PRV p� PRESSURE REDUCING VALVEw ROOF OPENING NOT COMPLETED DURING WORKING HOURS. LPS -LPS- LOW PRESSURE STEAM SUPPLY PIPING(0-15#) ,( I I d LOUVER WITH SCREEN (E) EXISTING PTRV PRESSURE AND/OR TEMPERATURE RELIEF VALVE z I 6. COORDINATE ALL DUCTWORK AND PIPING WITH EQUIPMENT, STRUCTURE, '_X V LPC --LPC-- LOW PRESSURE CONDENSATE RETURN PIPING MVD r .. MANUAL VOLUME DAMPER (N) NEW -, -mi . PLUG VALVE ETC. `r 1. (16# 60#) (R) P6RTNERSHIP MPS -MPS- MEDIUM PRESSURE STEAM SUPPLY PIPING - MOTOR OPERATED DAMPERRELOCATED GV �4- �4- GATE VALVE 7. CONTRACTOR SHALL BE RESPONSIBLE FOR DEACTIVATION OF ROOF- MPC --MPC-- MEDIUM PRESSURE CONDENSATE RETURN SPIN-IN FITTING WITH MVD (F) FUTURE -C“:1- VERTICAL PIPE VALVE MOUNTED EQUIPMENT AND ASSOCIATED INDOOR EQUIPMENT. ONLY ONE ARCH I T E C T S 2. PIPING - - UNIT SHALL BE TAKEN OUT OF SERVICE AT ANY TIME, WITH REMAINDER OF HPS -HPS- HIGH PRESSURE STEAM SUPPLY PIPING(61#-125#) FD 0 - DUCT FIRE DAMPER S POINT OF CONNECTION,NEW TO EXISTING GLV GKI - GLOBE VALVE UNITS LEFT OPERATIONAL. HPC --HPC-- HIGH PRESSURE CONDENSATE RETURN PIPING FSD ® COMBINATION DUCT SMOKE&FIRE DAMPER S POINT OF DISCONNECTION(DEMO) BFVI- - BUTTERFLY VALVE ?901 Blake Street, Suite 100 3 - 8. CONTRACTOR SHALL NOT SHUT DOWN /TAKE OUT OF SERVICE ANY SYSTEMS Denver Denver, CO 80205 PC - PC - PUMPED CONDENSATE PIPING SD ® DUCT SMOKE DAMPER DIRECTION OF FLOW IN PIPE BV -al- -14- BALL VALVE WITHOUT FIRST COORDINATING WITH OWNER AND PREPARING M.O.P. 303.861.8555 BBDBBD BOILER BLOWDOWN PIPING - DUCT SMOKE DETECTOR DUCTWORK,PIPING AND EQUIPMENT TO BE REMOVED CV tet- - - CHECK VALVE - Consultant BF - BF - BOILER FEED WATER PIPING DAD V DUCT ACCESS DOOR DIA DIAMETER D'Q SOLENOID VALVE 4. RL - RL - REFRIGERANT LIQUID PIPING - WAD WALL ACCESS DOOR I?, BUTTERFLY SOLENOID VALVE TURNING VANES IN DUCT ELBOW RS -- RS -- REFRIGERANT SUCTION PIPING . NIC NOT IN CONTRACT -HbHl HOSE END DRAIN VALVE PLUMBING NOTES: 5. RHG -RHG- REFRIGERANT HOT GAS PIPING EP E ELECTRIC-PNEUMATIC CONTROL VALVE AFF ABOVE FINISHED FLOOR _ P/T T P/T PRESSURE/TEMPERATURE TAP DEMOLITION GENERAL NOTES : PE 9: PNEUMATIC-ELECTRIC CONTROL SWITCH GC GENERAL CONTRACTOR I,/i STRAINER 1. CONTRACTOR SHALL NOT SHUT-OFF/PUT OUT OF SERVICE ANY CATOR RU MA 6. TT ®TT THERMOSTATIC STEAM TRAP TS TEMPERATURE SENSOR MC MECHANICAL CONTRACTOR I /1 STRAINER W/SLOWDOWN SYSTEMS/SERVICES WITHOUT FIRST COORDINATING WITH OWNER. 1. EXISTING ITEMS TO REMAIN ARE DENOTED LIGHTLY UNLESS OTHERWISE & ASS 0 CR A T E s , o F&T ...FST FLOAT AND THERMOSTATIC STEAM TRAP O WALL MOUNTED THERMOSTAT EC ELECTRICAL CONTRACTOR NOTED.ALL ITEMS SHOWN HATCHED SHALL BE REMOVED UNLESS FLEXIBLE PIPE CONNECTOR OTHERWISE NOTED. 2. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING IBT INVERTED BUCKET STEAM TRAP O WALL MOUNTED CARBON DIOXIDE SENSOR THERMOMETER CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK AND SHALL NOTIFY 896 Tabor Street 420 W.Lincolnway laT Lakewood,CO 80401 Cheyenne,WY 82001 7. THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOR RESOLUTIONS. 2. CONTRACTOR SHALL NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY SYSTEMS 303.232.6200(P) 307.274.3830(P) TCVI (2 OR 3-WAY)TEMPERATURE CONTROL VALVE V UNIT MOUNTED THERMOSTAT PRESSURE GAUGE OR SERVICE WITHOUT FIRST COORDINATING WITH THE OWNER. 303.233.3701(F) 303.233.3701(F) 8. 3. THIS CONTRACTOR SHALL COORDINATE LOCATIONS OF PIPING WITH OTHER �� VENTURI METER H HUMIDISTAT Q SIGHT GLASS www.catorruma.com D TRADES AND ADVISE ARCHITECT/ENGINEER OF ANY POSSIBLE CONFLICTS. 3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE AND D 9. T CALIBRATED BALANCING VALVE ► UNDERCUT DOOR C.A.P. ® CEILING ACCESS PANEL VERIFY EXACT LOCATIONS, ELEVATIONS AND DIMENSIONS OF STRUCTURAL UNDERSTAND THE EXTENT OF THE REMODEL WORK REQUIRED PRIOR TO MEMBERS AND OPENINGS. BID. NO EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE RSV -it- REFRIGERANT SERVICE VALVE L LOUVER -1(12/ PUMP END RESULT AS INDICATED BY THE CONTRACT DOCUMENT. 10. R DUCT RISE TB THRUST BLOCK 4. SEE SPECIFICATIONS FOR WATER HAMMER ARRESTOR SIZING.ALL FLUSH DPS a DIFFERENTIAL PRESSURE SWITCH •. VALVES AND SOLENOID OPERATED EQUIPMENT SHALL HAVE A WATER 4. CONTRACTOR SHALL DETERMINE AND COORDINATE THE EXACT EXTENT OF MAV MANUAL AIR VENT D DUCT DROP HAMMER ARRESTOR. DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT 11. DOCUMENT. AAV , AUTOMATIC AIR VENT A.L. ACOUSTICALLY LINED DUCTWORK i 1 5. SEE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZING TO INDIVIDUAL FS FLOW SWITCH TCOAD TEMPERATURE CONTROL OUTSIDE AIR DAMPER DOUBLE/SINGLE LINE DUCT LEGEND PLUMBING FIXTURES. 5. PRIOR TO COMMENCEMENT OF ANY DEMOLITION WORK,VERIFY EXISTING (Not all symbols listed below are used on these drawings) CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR EJ -0 EXPANSION JOINT TCRAD TEMPERATURE CONTROL RETURN AIR DAMPER 6. ALL EXISTING FIXTURES AND EQUIPMENT TO BE REMOVED SHALL HAVE ALL RESOLUTION. SINGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE OW Mk 1 ASSOCIATED PIPING CONTROLS, HANGERS, SUPPORTS AND ANY tib,,p,8 Lie.'' , BJ -40 - BALL JOINT EXPANSION COMPENSATOR TCEAD TEMPERATURE CONTROL EXHAUST AIR DAMPER RIGI FLEX 6. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ���� C" •�••. r fi S S S S RIGI FLEX MISCELLANEOUS ASSOCIATED SERVICE OR PART REMOVED COMPLETELY. ENTIRETY UNLESS OTHERWISE NOTED. REMOVED ITEMS SHALL BE TURNED y�1 *• 10. C*:�(�` f� SP IN WC STATIC PRESSURE IN INCHES WATER COLUMN SEE DUCT SJ 0 OVER TO THE OWNER UNLESS OTHERWISE NOTED AND STORED IN THE AREA / fir4D TAKE-OFF DETAI 7. REFER TO ARCHITECTURAL DRAWINGS FOR ROOF PENETRATION DETAILS. DESIGNATED BY THE OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF SD N SUPPLY AIR DEVICE S 45° TEE(ROUND) 90° TEE(RECTANGULAR) FLEX DUCT 90° RADIUS ELBOW 8. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE ELEVATIONS AND ALL ITEMS THE OWNER CHOOSES NOT TO ACCEPT. RG RETURN AIR DEVICE :=�0 � ��t v R LOCATIONS. J � CWS,CWR/HWS,HW S S S S 7. WHERE EXISTING PIPING, T.C. TUBING/WIRING ETC.ARE TO BE REMOVED _ 1 F' 44 1 RG RETURN AIR DEVICE WITH SOUND BOOT \ CONICAL S S �f `\A.,'' �' \ I I 9. SEE ARCHITECTURAL CONSTRUCTION DOCUMENTS FOR DIMENSIONED FROM WALLS WHICH ARE REMAINING,THE WALLS SHALL BE REPAIRED TO ��f \-0 e•a4s., � YYYrn�aa SUPPLY&RETURN BRANT EG ® EXHAUST AIR DEVICE TEE S f I LOCATION OF PLUMBING FIXTURES AND WALLS. MATCH ORIGINAL CONDITIONS. f�f�/1/41`40NAL E\\N�� iy- u5 PIPING TO TERMINAL UNIT I��r�!/�lillllll����� 45° TEE(RECTANGULAR) 90° TEE(ROUND) MANUAL VOLUME DAMPER 90° ELBOW 2.1 (f p KEYNOTE 45`TAKEOFF 10. PROVIDE CLEANOUTS IN ACCESSIBLE LOCATIONS PER THE PROJECT 8. WHERE EXISTING PIPING TO BE REMOVED PASSES THROUGH FLOORS, THEY 1 SPIN IN SPECIFICATIONS AND LOCAL PLUMBING CODES. SHALL BE CUT BACK TO WITHIN CONCRETE AND FILLED WITH GROUT TO 3. lU"I ACHIEVE A SMOOTH AND EVEN FINISH WITH CONCRETE SURFACE. r 1 PI S PLUMBING LEGEND DAMPERe' VOLUME / Issuance 4. DUCT SPLIT N IL GRD N N REDUCER 45° ELBOW (Not all symbols listed below are used on these drawings) RUNOUT ./ PERMIT 06/30/17 ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION CW - DOMESTIC COLD WATER PIPING SCO SURFACE CLEANOUT ' FIRE PROTECTION LEGEND \ Revisions Date HW ---- DOMESTIC HOT WATER PIPING FCO O FLOOR CLEANOUT (Not all symbols listed below are used on these drawings) FIRE PROTECTION PLAN NOTES . HWC ----- DOMESTIC HOT WATER CIRC.PIPING WCO CHI WALL CLEANOUT ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION C-SW --- SW- SOFTENED DOMESTIC COLD WATER PIPING COT 0-I CLEANOUT TEE F - F - FIRE SERVICE PIPING Qo NEW SPRINKLER HEAD H-SW ----SW- SOFTENED DOMESSTIC HOT WATER PIPING LCO bC S LINE CLEANOUT FS Fg- FIRE SPRINKLER PIPING 0 EXISTING SPRINKLER HEAD 1. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES C NECESSARY FOR THE INSTALLATION OFA COMPLETE AND PROPERLY C 140°HW ----1404- DOMESTIC HOT WATER PIPING @ TEMPERATURE FIXTURE OR DRAIN P-TRAP WSP -N20- WET STANDPIPE ® RELOCATED SPRINKLER HEAD FUNCTIONING FIRE PROTECTION SYSTEM. SHOWN ✓ VENT PIPING AD AREA DRAIN k O.S.&Y.VALVE W/TAMPER SWITCH > SIDEWALL SPRINKLER HEAD 2. THE FIRE PROTECTION WORK INVOLVES ENGINEERING AND DESIGN BY AV - AV- ACID RESISTANT VENT PIPING FD 0 FLOOR DRAIN(ROUND GRATE) FS g FLOW SWITCH D24 DRY SPRINKLER HEAD(SHAFT) THE CONTRACTOR TO DETERMINE THE EXTENT OF NEW WORK AND THE MODIFICATION AND EXTENSION OF EXISTING SYSTEMS TO W - w - WASTE PIPING(ABOVE FLOOR IN BUILDING) FS ® FLOOR SINK(SQUARE GRATE) PIV I POST INDICATOR VALVE FHC FIRE HOSE CABINET PROVIDE FULL COVERAGE TO THE PROJECT AREA SHOWN ON THESE W -- W -- WASTE PIPING(BELOW FLOOR IN BUILDING) RD/OD OO ROOF DRAIN OR OVERFLOW DRAIN FH 1-6-1FIRE HYDRANT FVC FIRE VALVE CABINET AND THE ARCHITECTURAL PLANS. AW - AW- ACID RESISTANT WASTE PIPING(ABOVE FLOOR IN BUILDING) 4 GAS PRESSURE REDUCING VALVE FDC < FIRE DEPARTMENT CONNECTION A/S AUTOMATIC FIRE SPRINKLER 3. THE INFORMATION PRESENTED ON THESE DRAWINGS IS DIAGRAMMATIC. IT DOES NOT NECESSARILY REPRESENT ALL ELBOWS, AW --AW-- ACID RESISTANT WASTE PIPING(BELOW FLOOR IN BUILDIN 3) VB _I-7_ ATMOSPHERIC VACUUM BREAKER OFFSETS, HANGERS, ETC., REQUIRED FOR A COMPLETE WORKING • , SYSTEM. GD -GD- GREASE DRAIN(WASTE LINE TO GREASE INTERCEPTOR) BFP -F.1-FC1- DOUBLE CHECK BACKFLOW PREVENTER IW - 1W- INDIRECT WASTE PIPING SA SHOCK ARRESTOR W/ISOLATION VALVE e - 1 4. ALL FIRE PROTECTION SYSTEMS INSTALLED SHALL BE IN ACCORDANCE - s - - LABORATORY / MEDICAL SERVICES LEGEND WITH ORDINANCES., 14, 20, ETC.AND LOCAL BUILDING CODES AND S SANITARY SEWER PIPING(OUTSIDE BUILDING) GC GAS SHUT-OFF VALVE ST --ST-- STORM SEWER PIPING(BELOW GRADE OUTSIDE BUILDING) (Not all symbols listed below are used on these drawings)STOP AND DRAIN VALVE 5. FIRE PROTECTION CONTRACTOR SHALL COORDINATE THE LOCATION Project Information - SSD -55DSUB-SURFACE DRAIN PIPING FC HWC BALANCING VALVE ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION OF ALL NEW FIRE PROTECTION EQUIPMENT AND PIPING WITH ALL 02 - 02- OXYGEN PIPING Q° OXYGEN SERVICE OUTLET OTHER TRADES PRIOR TO SUBMITTAL OF SHOP DRAWINGS AND SD - SD- STORM DRAIN PIPING(ABOVE FLOOR IN WH +- WALL HYDRANTSYSTEM INSTALLATION, SO AS NOT TO INTERFERE WITH THE ROUTING Y BUILDING) VAC -VAC- VACUUM PIPING I VACUUM SERVICE INLET OF NEW DUCTWORK, PLUMBING PIPING, ETC. SD --SD-- STORM DRAIN PIPING(BELOW FLOOR IN HB HOSE BIBB p BUILDING) N20 -N20- NITROUS OXIDE PIPING I WASTE ANESTHESIA GAS DISPOSAL INLET OD - OD- OVERFLOW DRAIN PIPING(ABOVE FLOOR IN YH g❑ YARD HYDRANT 6. PROVIDE ALL FITTINGS, RISER NIPPLES,ARM-OVERS, HANGERS, ETC. BUILDING) N - N - NITROGEN PIPING 4 NITROUS OXIDE SERVICE OUTLET TO MAINTAIN CONFORMANCE WITH APPLICABLE STANDARDS AND TO OD --OD-- OVERFLOW DRAIN PIPING(BELOW FLOOR IN BUILDING) MH MANHOLE POSITION THE SPRINKLERS IN THE PROPER LOCATIONS. MA -MA- MEDICAL AIR PIPING 4 NITROGEN SERVICE OUTLET A - A - COMPRESSED AIR CI CAST IRON CO2 -0O2- CARBON DIOXIDE I NATURAL GAS SERVICE OUTLET 7. SEAL ALL PIPE PENETRATIONS THROUGH FIRE RATED WALLS AND G - G - NATURAL GAS VCP VITRIFIED CLAY PIPE CEILINGS WITH FIRE STOPPING MATERIALS AS REQUIRED. PIPING WAGD -VVAGD- WASTE ANESTHESIA GAS DISPOSAL 4 LABORATORY/MEDICAL AIR SERVICE OUTLET CB CATCH BASIN 8. FOR REMODEL AREAS NEW SPRINKLERS SHALL MATCH EXISTING DI - DI - DEIONIZED WATER PIPING I CARBON DIOXIDE SERVICE OUTLET SPRINKLERS. ~ VTR VENT THRU ROOF I.{) H - H - HYDROGEN PIPING ZVB ZONE VALVE BOXZ CD IE INVERT ELEVATION 9. PROVIDE WORKING DRAWINGS AND HYDRAULICALLY CALCULATE THIS NL - NL- LIQUID NITROGEN PIPING MGO MEDICAL GAS OUTLET FIRE SPRINKLER SYSTEM PER NFPA-13 WHERE REQUIRED BY THE O PVC POLYVINYL CHLORIDE LOCAL AUTHORITY HAVING JURISDICTION. CO LA - LA- LABORATORY COMPRESSED AIR PIPING AAP AREA ALARM PANEL 0 B G - G - NATURAL GAS PIPING MAP MASTER ALARM PANEL 10. PROVIDE FIELD COORDINATION OF PIPING AND SPRINKLER B I" Z U INSTALLATIONS WITH DUCTWORK, LIGHTS, SMOKE DETECTORS, J DIFFUSERS, ETC. Q 0 a > FUEL OIL PIPING LEGEND Q z LLI (Not all symbols listed below are used on these drawings) 0 ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION 0 FOS -FOS- FUEL OIL SUPPLY PIPING T PRESSURE RELIEF VALVE Z Z_ Et a) FOR --FOR-- FUEL OIL RETURN PIPING VACUUM GAUGE W/COCK VALVE CD FOF - FOF- FUEL OIL FILL PIPING PRESSURE GAUGE W/COCK VALVE 'I CO FOV --FOV-- FUEL OIL VENT PIPING -1=I FUSIBLE LINK VALVE ^ c 0 FOO -F00- FUEL OIL OVERFLOW PIPING ,-la` FUEL OIL HAND PUMP CO W LL DPO -DPO- DAY TANK PUMP OUT PIPING < CO GFOS -GFOS- GENERATOR FUEL OIL SUPPLY PIPING LU 0. CO GFOR --GFOR-- GENERATOR FUEL OIL RETURN PIPING t J Sheet Information A A Sheet Title: MECHANICAL LEGENDS & NOTES Sheet Number: a. M 0 0 1 75 „, ■ M Ca N- O M DPA Project: 15924.00 COPYRIGHT -DAVIS PARTNERSHIP, 1 2 3 4 5 6