B17-0340_M-101.75_1507837260.pdf
1 2 3 4 5 6 ,,, vi,,,.. �_1.E19 1 E19 0.7 sE19 8.5E192r�•►,'sKEYNOTES , .0s, 340,1. H14 FOLLOWING INSTALLATION OF NEW CRAC AND RELOCATION OF 10/12/17 IMAGING EQUIPMENT, DEMO EXISTING TRANE COOLING UNIT, EXISTING RELATED CONDENSING UNIT,AND EXISTING WALL MOUNTED STEAM HUMIDIFIER. PACKAGE AND RETURN TO OWNER IF REQUESTED BY OWNER. 8e200imo 00 MO MI IS H22 NEW ARCHITECTURAL RATED WALLS WILL BE ADDED WHICH WILL liL7INTERFERE WITH CEILING RETURN (AREA IS NOT DUCTED RETURN). )-. , - - E.4 PROVIDE TRANSFER GRILLES WITH SMOKE DAMPERS. PROVIDE o MAXIMUM ALLOWABLE SIZE TRANSFER DUCTS TO LIMIT STATIC IIU . . PRESSURE. P18 WITHIN BOUNDS OF RENOVATION SCOPE AREA, MODIFY THE 111 . 11111 - �� EXISTING WET FIRE PROTECTION SYSTEM AS REQUIRED IN 7e2001 _ I ACCORDANCE WITH NFPA-13 AND THE LOCAL AHJ REQUIREMENTS 111111111111 E -/ TO ACCOMODATE THE ARCHITECTURAL REMODEL. MODIFY EEXISTING SPRINKLER ZONES TO MATCH LIFE SAFETY ZONING. - MATCH EXISTING SPRINKLERS. III . 1. 11 rT DEMO EXISTING DCW I_ Q5 PROVIDE SNOWMELT SYSTEM FOR RAMP AT TEMPORARY DOCK CONNECTION TO ENTRANCE IN ENABLING PHASE. SNOWMELT EXTENTS ARE 1111111111 ■■ EXISTING HUIMIDIFIER. INDICATED ON ENABLING SITE PLAN. SNOWMELT EQUIPMENT AND POINT OF CONNECTION TO EXISTING SYSTEM IS IS INDICATED ON e2001— -1LR) I ENABLING LEVEL 1 PIPING PLAN. PROVIDE SNOWMELT I- - _ CONTROLLER, PUMP,AND FLAT PLAT HEAT EXCHANGER FOR !\ A _ _ el" 1 ! SYSTEM WITHIN LEVEL 1 STORAGE ROOM AS INDICATED. _ _ - � 1 t PARTNERSHIP ]Tt— 1 c ARCHITECTS 1/2"DCW TO CRAC UNIT HUMIDIFIER. c_, I I - -901 Blake Street, Suite 100 0.1 S 09 PROVIDE RPBFP.FIELD VERIFY EXISTING VALVED CONNECTION 1 Denver Denver, CO 80205 PRIOR TO BID. 303.861.8555 I — I Consultant I 1 1 1 1 II II 7 , , , a° °° I ° IA .4 ,e197: e1978 ',e197: (e197:, 7E1978 7.69 0: / ; , CATOR RU MA AA � & ASSOCIATES , CO . FHe 002 002 1 e200' .07 A ° A A ° A 896 Tabor Street 420 W.Lincolnway 1:e197 a ��l -- 4 s A Lakewood,CO 80401 Cheyenne,WY 82001 Z �■J - :1 ®' OVERALL DOMESTIC WATER PLAN - LEVEL 1 303.232.6200(P) 303.233.37 0(P) 1, C CI 303.232.6200(F) 303.233.3701(F) www.catorruma.com D c^� ° H SCALE: 1/8" = 1'-0" D AC\ 0 2 / 1 E w/o 1 3 I.E19 6"� 9 tl?'' 1 Ss FM 2 , 0 A 160CFM E1: 10E19 : 14E19 0.1 1,E19 : 1.E19 : 1 E19 : 0.7 :E19 8sE19 8 O � -107.7' 1 6"❑ { C L III '2 o •.I I , T n ' ?uH _I 1 -107. 5 e/6 I ° ❑_ , � ® {!{! Viii df _ I(Ce1978 it/ LJ �i�j�����© �� �� -.,RIY • 1© r • •,r�rJ ■ - 85 CFM ___ x �� h �-\ I ti Lie- • v 350 /X x 17 I _1WATER S�■� $ 230 CFM II �I I� - 1• s ► 6�❑ -:✓_ 1 - I I ' �7 - ° e2001 I IRI I r - • •v 1 I 75 CFM / 1 6 ❑ I 0/0 — - 1 - E.4 + .n / c: 75 CFM , , , , ,/ / ; 16/7 28/7 r�■� x\ O �PC°421 /80 3744 O10/10 /� - EF-10 .,�'�UNAL E�,�`'���, 350 �J2H7i 1 �� -- 2„MPS UP I HWR_ 1j7j11111 {II����� U / EBE 7e200'I ❑ 70 I fllll{{ri 111 u _ - I IT 10 r © SWR 300 CFM , — r I �;�- Issuance el 0 6"❑ / 22"x6" X i I 85 X `� ® N 450CFM 1 ® DOOR L. UVEB e2oo PERMIT 06/30/17 Z A (S[r22/10 A.L. — �Y 111 iL:\ 11� 1 �r�,a,� lit ., ,-/- ® PROVIDE 3/4"PC DRAIN C 1 Revisions Date 1111 la 36x4 GRILLE ® -40.- (4' 71 � 20/5 r. �. I 10” LINE TO FLOOR SINK IN 1 , r-- -ir, • I N �� I-0- 0 Q 350CFM NEARBYAHUROOM. 3/4"PC—. 1 Rio E iii: x 3 ©I I. 1 `7/ SII I I I n C ��' 1 •.i1J_ I O,ono- 1 I< - �i } C 350 I I �I I cynITA I- L I nr.'I` I I 1 r" 580 CFM 6"0 1� �I■ — .• 0 I ---- I 10 0 I H-1- HUMIDIFIER — - I A^�'�' AO 265 '� I ®\ ^ I ON WALL,BELOW / \ — ® _ V 1 OA 8"o L 6"0 �\`�I I WIIREMOULDING 150 I C "NORT�MODEL ��' - 1 1 1 � I N200 WITH REMOTE 1 — I /4- 13__ - in 0 265 ./� 110C M HUMIDISTAT. _ 1 © ��� O f I■ 100 CFM X I I 1 _� 30/8 / \ �� ® 0 I I—_ I — ei )�_ Itl�o�r,„���I'^ U PI 6'❑ - "Ow - -I\ _ �� _ 6 ❑��I'" 100 CFM _ 1. ,,t jk 1 _ �� _0 I E- E, wr ■ i==(- Iiir. .. i.,... _„.._ . , .,„,... .. _ ,. E MD T h_ 7. E-4 u 1r° f Project Information 1 .111 lII I 1 — I I 7e200 - - - - - = - - - IM I �1 - 1111 Ei!!Ji IGS - ET- 4I II II .�,- i T M 14 1 0 IFJ d0 8e200 — ,_rIr tillI© 1I �� l� IS ■ a°i 12° Ll: 0 s � III �I®■111■I■N �1 N C C �'' I ._ 1 )1 _ _ � r 1 I I _ I■ <L_�� L�,��■ n a..d lir" I -- — Loh- 12 �- fi 3/4" - ] -3�4" o - Z ,_ ♦ 1 (.0 � `� ' �ILS i_■.�=� OM c-� Illl�n�i1 1 IF.= P _ Ik • -g- XIX I O�II Iwo —FP ■_ _ ■ 1 I1. 0 � `J F.A. ■ �_I mm �/ i ply `• — "� mi ,I / NORMALLY CLOSED 12"BACKUP LZ'k / ❑ J ' 11 /� • • m� �—� �� SUPPLY DUCT FOR SCANNING ROOM 0 1 — Q W •.- �� I I -'I 7i/ I � -4" 0 a > �I ` � m - .� IIS o =- - -�IIII `sir ‘iim. I --- . ,_ i.../ .1 . km , . 1 — \ e200 - • :�� �� - I' I IIL��:;' u : IT% �r1- ■ h,.111 V= � IF IMIll n { - - - Z Z ml�4I II I — L- n �.e. Lt -a TMJ T_ 11111 1 _ „,, �' I OD izz-mi. - = 0 I 0 \ " I I e I CD li-i .__ ._ =INJ �� ""t, mil• ' CU � -= 11X I,_, �'■ 3/4" �- vIIO III I ¢ W LL ■ 11 . Cili 1 , - N I 1.4117111 i� I ■1111 PI■ ���� _ �I - - _ 1- - - 1 LU Cn ►7B iniliMM% — - ::A 1 I e `,..II�COICII. �1� IBillr - - - - 1 t- Ico y/ l li' \ II t_ -- [■)1� ' fil I 1 I L I L 3/4 �T I11E11 :11:!!!!!!!!!! 1 Op �������� v r 111111. `' SII ■ I - e2001 ■� a uuIA I ,� :117.1.7� ` I IWR IMM � Rn 1hllll■� �_ _■ �� HW, _ ill CWR / �II�\iii -----imi1 , z 1 I 1rill #111 �. , ��S j im - .�I - CWS CWS IC 1 . 4 aH F�1 — I W — �3/4" — II �� IIII■. L I�1� d❑ lei.,., 1111EIMIlmaiLWEII6j _ 1 s 11 CUH ti)m • Illl�l i-' % I /� • III'" --_ n_ _= N - ' _ I ------ q�----� I— I �',---_� I I =-----i } u , 1 ' �7+ SMP Q5 I r I *- rk rr ( w) ° I ° I 1 - I I I 1 I � I II I � - I ° ° l■ �- 7 I PIII�I■i, ,x7, I� o`III �u� I 1 BELOW GRADE ► A I - I Sheet Information 7 REFER TO M-100.75 FOR SNOWMELT AREA SIERVED BY THIS SYSTEM. , a A - ° A I Sheet Title: A e2oo1 �_ 7 1 A IiI: a � � -- 1 LEVEL 1 HVAC AND PIPING I I I PLANS - ENABLING - 11 I I e200 :e20+2001 (.- I 2001 e200 .07 e204-200 t.- :: e2001 .07 Sheet Number: LEVEL 1 HVAC PLAN — ENABLING IM SCALE: 1/8" = 1'-0" 1 01 N MLEVEL 1 HVAC PIPING PLAN - ENABLING - . 75 M H SCALE: 1/8" = 1,-0" E, DPA Project: 15924.00 COPYRIGHT -DAVIS PARTNERSHIP, 1 1 2 3 1 4 1 5 6