HomeMy WebLinkAboutB17-0340_M-101.75_1507837275.pdfT
H
~
T
T
T
T
T
T
T
T
AC
2
CUH
1
6"∅
85
10/10
350
C
A
10"∅
265
10"∅
265
30/8
6"∅
100 CFM
6"∅
110 CFM
6"∅
6"∅
100 CFM
6"∅
HUMIDISTAT.
WITH REMOTE
350CFM
10"∅
22/10 A.L.
20/5
N200
"NORTEC" MODEL
WIREMOULDING
ON WALL, BELOW
HUMIDIFIER
H-1
AC-3
DOOR LOUVER
450CFM
22"x6"
EF-1
EBB
8/8
6"∅
8/6
160 CFM
6"∅
28/7
6"∅
10/6
16/7 20/5
350
6"∅
100 CFM
6"∅
85 CFM
75 CFM
6"∅
230 CFM
8"∅
75 CFM
6"∅
C
10/10
350
580 CFM
8"∅
150
A
A
SWR 300 CFM
36x4 GRILLE
H
H ~ ~ ~~
~
~~
CWR
CWR
CWR
CWS
CWS
CWS
HWR
HWR
HWR
HWR
HWS
HWS
HWS
HWS
HR
HS
1r"
1r"
CUH
3"
P-9
WATER HEATER
HWR
HWS
HWR
4"
3/4"
1"
3/4"
4"
1"
3/4"
3/4"
1" 1"
3/4"
3/4"
1 1/4"
3/4"
1"
3/4"
3/4"
2"MPS UP
H
~
~
~
~
~
~
C
P
C
E
s"
s"
1r"
i"
5
MD-107.75
3
M-107.75
H22
H22
H22
H22
H22
H22
H14
2
M-107.75
1
CRAC
C
1000
24" / 12"
12"
N.C.
NORMALLY CLOSED 12" BACKUP
SUPPLY DUCT FOR SCANNING ROOM
3
M-107.75
EW1
SMHX
EW1
SMP Q5
H14
BELOW GRADE
3/4" PC
PROVIDE 3/4" PC DRAIN
LINE TO FLOOR SINK IN
NEARBY AHU ROOM.
1
CRAC
REFER TO M-100.75 FOR SNOWMELT AREA SERVED BY THIS SYSTEM.
1
CRAC
1/2" DCW TO CRAC UNIT HUMIDIFIER.
PROVIDE RPBFP. FIELD VERIFY
EXISTING VALVED CONNECTION
PRIOR TO BID.
DEMO EXISTING DCW
CONNECTION TO
EXISTING HUMIDIFIER.
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
EAST
WING
ENABLING
6/30/2017
12:32:28 PM
15924.00
M-101.75
LEVEL 1 HVAC AND PIPING
PLANS - ENABLING
06/30/17
PERMIT EAST
WING
ADDITION
180 S Frontage Rd W, Vail, CO 81657
SCALE: 1/8" = 1'-0"
LEVEL 1 HVAC PLAN - ENABLING
KEYNOTES
H14 FOLLOWING INSTALLATION OF NEW CRAC AND RELOCATION OF
IMAGING EQUIPMENT, DEMO EXISTING TRANE COOLING UNIT,
EXISTING RELATED CONDENSING UNIT, AND EXISTING WALL
MOUNTED STEAM HUMIDIFIER. PACKAGE AND RETURN TO OWNER IF
REQUESTED BY OWNER.
H22 NEW ARCHITECTURAL RATED WALLS WILL BE ADDED WHICH WILL
INTERFERE WITH CEILING RETURN (AREA IS NOT DUCTED RETURN).
PROVIDE TRANSFER GRILLES WITH SMOKE DAMPERS. PROVIDE
MAXIMUM ALLOWABLE SIZE TRANSFER DUCTS TO LIMIT STATIC
PRESSURE.
P18 WITHIN BOUNDS OF RENOVATION SCOPE AREA, MODIFY THE
EXISTING WET FIRE PROTECTION SYSTEM AS REQUIRED IN
ACCORDANCE WITH NFPA-13 AND THE LOCAL AHJ REQUIREMENTS
TO ACCOMODATE THE ARCHITECTURAL REMODEL. MODIFY
EXISTING SPRINKLER ZONES TO MATCH LIFE SAFETY ZONING.
MATCH EXISTING SPRINKLERS.
Q5 PROVIDE SNOWMELT SYSTEM FOR RAMP AT TEMPORARY DOCK
ENTRANCE IN ENABLING PHASE. SNOWMELT EXTENTS ARE
INDICATED ON ENABLING SITE PLAN. SNOWMELT EQUIPMENT AND
POINT OF CONNECTION TO EXISTING SYSTEM IS IS INDICATED ON
ENABLING LEVEL 1 PIPING PLAN. PROVIDE SNOWMELT
CONTROLLER, PUMP, AND FLAT PLAT HEAT EXCHANGER FOR
SYSTEM WITHIN LEVEL 1 STORAGE ROOM AS INDICATED.
SCALE: 1/8" = 1'-0"
LEVEL 1 HVAC PIPING PLAN - ENABLING
SCALE: 1/8" = 1'-0"
OVERALL DOMESTIC WATER PLAN - LEVEL 1
10/12/17