Loading...
HomeMy WebLinkAboutB17-0340_M-101.75_1507837275.pdfT H ~ T T T T T T T T AC 2 CUH 1 6"∅ 85 10/10 350 C A 10"∅ 265 10"∅ 265 30/8 6"∅ 100 CFM 6"∅ 110 CFM 6"∅ 6"∅ 100 CFM 6"∅ HUMIDISTAT. WITH REMOTE 350CFM 10"∅ 22/10 A.L. 20/5 N200 "NORTEC" MODEL WIREMOULDING ON WALL, BELOW HUMIDIFIER H-1 AC-3 DOOR LOUVER 450CFM 22"x6" EF-1 EBB 8/8 6"∅ 8/6 160 CFM 6"∅ 28/7 6"∅ 10/6 16/7 20/5 350 6"∅ 100 CFM 6"∅ 85 CFM 75 CFM 6"∅ 230 CFM 8"∅ 75 CFM 6"∅ C 10/10 350 580 CFM 8"∅ 150 A A SWR 300 CFM 36x4 GRILLE H H ~ ~ ~~ ~ ~~ CWR CWR CWR CWS CWS CWS HWR HWR HWR HWR HWS HWS HWS HWS HR HS 1r" 1r" CUH 3" P-9 WATER HEATER HWR HWS HWR 4" 3/4" 1" 3/4" 4" 1" 3/4" 3/4" 1" 1" 3/4" 3/4" 1 1/4" 3/4" 1" 3/4" 3/4" 2"MPS UP H ~ ~ ~ ~ ~ ~ C P C E s" s" 1r" i" 5 MD-107.75 3 M-107.75 H22 H22 H22 H22 H22 H22 H14 2 M-107.75 1 CRAC C 1000 24" / 12" 12" N.C. NORMALLY CLOSED 12" BACKUP SUPPLY DUCT FOR SCANNING ROOM 3 M-107.75 EW1 SMHX EW1 SMP Q5 H14 BELOW GRADE 3/4" PC PROVIDE 3/4" PC DRAIN LINE TO FLOOR SINK IN NEARBY AHU ROOM. 1 CRAC REFER TO M-100.75 FOR SNOWMELT AREA SERVED BY THIS SYSTEM. 1 CRAC 1/2" DCW TO CRAC UNIT HUMIDIFIER. PROVIDE RPBFP. FIELD VERIFY EXISTING VALVED CONNECTION PRIOR TO BID. DEMO EXISTING DCW CONNECTION TO EXISTING HUMIDIFIER. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 12:32:28 PM 15924.00 M-101.75 LEVEL 1 HVAC AND PIPING PLANS - ENABLING 06/30/17 PERMIT EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657 SCALE: 1/8" = 1'-0" LEVEL 1 HVAC PLAN - ENABLING KEYNOTES H14 FOLLOWING INSTALLATION OF NEW CRAC AND RELOCATION OF IMAGING EQUIPMENT, DEMO EXISTING TRANE COOLING UNIT, EXISTING RELATED CONDENSING UNIT, AND EXISTING WALL MOUNTED STEAM HUMIDIFIER. PACKAGE AND RETURN TO OWNER IF REQUESTED BY OWNER. H22 NEW ARCHITECTURAL RATED WALLS WILL BE ADDED WHICH WILL INTERFERE WITH CEILING RETURN (AREA IS NOT DUCTED RETURN). PROVIDE TRANSFER GRILLES WITH SMOKE DAMPERS. PROVIDE MAXIMUM ALLOWABLE SIZE TRANSFER DUCTS TO LIMIT STATIC PRESSURE. P18 WITHIN BOUNDS OF RENOVATION SCOPE AREA, MODIFY THE EXISTING WET FIRE PROTECTION SYSTEM AS REQUIRED IN ACCORDANCE WITH NFPA-13 AND THE LOCAL AHJ REQUIREMENTS TO ACCOMODATE THE ARCHITECTURAL REMODEL. MODIFY EXISTING SPRINKLER ZONES TO MATCH LIFE SAFETY ZONING. MATCH EXISTING SPRINKLERS. Q5 PROVIDE SNOWMELT SYSTEM FOR RAMP AT TEMPORARY DOCK ENTRANCE IN ENABLING PHASE. SNOWMELT EXTENTS ARE INDICATED ON ENABLING SITE PLAN. SNOWMELT EQUIPMENT AND POINT OF CONNECTION TO EXISTING SYSTEM IS IS INDICATED ON ENABLING LEVEL 1 PIPING PLAN. PROVIDE SNOWMELT CONTROLLER, PUMP, AND FLAT PLAT HEAT EXCHANGER FOR SYSTEM WITHIN LEVEL 1 STORAGE ROOM AS INDICATED. SCALE: 1/8" = 1'-0" LEVEL 1 HVAC PIPING PLAN - ENABLING SCALE: 1/8" = 1'-0" OVERALL DOMESTIC WATER PLAN - LEVEL 1 10/12/17