HomeMy WebLinkAboutB17-0340_MD-107.75_1507837283.pdf(E) 10" FLUE (E) 14" FLUE (E) OA INTAKE (E) OA INTAKE (D) MULTIZONE AHU O.A. INTAKE (AT END OF GABLED ROOF) 5 MD-107.75 (D) NG METER TO BE RELOCATED (E) PLUMBING VENT (E) TRANE EXHAUST FAN AND ENERGY RECOVERY COIL (E) 8" DOWN TO EF-2-1 (E) 10" DOWN TO HOOD (RELOCATE) EF-2-2 (E) DX COIL AC-1 (E) AHU FAN AND FURNACE (E) SA DOWN OUTSIDE AIR (E) EF-2-3 (E) FC-3 AND HEATING COIL (E) 22/22 RA DOWN (E) OA INTAKE PLENUM FOR FC-3 AND MULTIZONE AHU ON L2 (E) DX COIL (E) 24/22 SA DOWN (E) 10/10 EXH DOWN (E) 14/14 EXH DOWN (E) EXHAUST FAN (E) 14/14 EXH UP TO GOOSENECK TERMINATION (E) RETURN DOWN (E) EXHAUST (E) ENERGY RECOVERY PUMPS AND EXP TANK (E) 18/16 EXH DOWN (E) 14/14 EXH DOWN (E) AHU-1 WITH ENERGY RECOVERY AND DX COILS (E) 18/18 SA DOWN (D) OUTSIDE AIR LOUVERS (E) FC-2 (E) 20/18 RA DOWN (E) 20/18 SA DOWN (E) EXHAUST DUCTS APPROXIMATE LOCATION OF PEAKED ROOF END (D) OA DUCTWORK (D) OA DUCTWORK 22"x24" 22"x24" SEE PARTIAL ROOF CONDENSER PLAN ON THIS SHEET (E) CONDENSING UNITS (E) CONDENSING UNIT (E) VAC PUMP EXHAUST (E) WATER HEATER EXHAUST (E) BOILER FLUES (E) NG TO L2 STEAM BOILER ROOM (E) NG TO L2 HYDRONIC BOILERS (E) BOILER ROOM EXHAUST FANS (E) CONDENSING UNITS (E) SB-4 BOILER FLUE (E) STEAM VENT (E) STEAM AND CONDENSATE RACKED ON WALL TO WEST WING 6" G 6" G 5 ACC MITSUBISHI MR. SLIM LABELED "CT WALL BY COMPUTERS" TRANE LABELED "CT/CU-2" MITSUBISHI MR. SLIM. R410-A STEADMAN IT MITSUBISHI MR. SLIM. R410-A BELIEVED TO SERVE ADMINISTRATION. TO BE DEMO'D WITH EAST WING AND NOT RELOCATED. SMALL CONDENSER BELIEVED TO SERVE SURGICAL PLANNING. TO BE DEMO'D WITH EAST WING AND NOT RELOCATED. H1 H1 E10 ACC E7 ACC E9 ACC E8 ACC E6 ACC E5 ACC E4 ACC 4 ACC DEMO AND REPLACE WITH NEW CRAC-1 EXISTING OFFSET AROUND ROOF SOFFIT EXISTING METER LOCATION ON GRADE EXISTING NG BELOW GRADE 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 12:33:05 PM 15924.00 MD-107.75 ROOF MECHANICAL DEMO PLAN - ENABLING 06/30/17 PERMIT EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657 SCALE: 1/8" = 1'-0" ROOF DEMOLITION MECHANICAL PLAN - EAST ENABLING KEYNOTES H1 RELOCATE EXISTING DX SPLIT SYSTEM CONDENSER. INCLUDE REPLACEMENT OF LINESETS ALL THE WAY BACK TO THE EVAPORATOR IN STEADMAN IT CENTER. SCALE: 1/8" = 1'-0" ROOF MECHANICAL DEMO PLAN - CONDENSING UNITS 1/8" = 1'-0" 5 EXISTING GAS SERVICE SECTION 10/12/17