HomeMy WebLinkAboutB17-0340_S-201-1_1507837288.pdfNOTES: 1. 90 DEG CORNER AND INTERSECTION IS SHOWN. WALLS MEETING AT OTHER ANGLES SHALL HAVE (a) BLOCK OVERLAPPING 4" MIN AT ALL HEAD JOINTS OR (b) FACE SHELL BROKEN OPEN AND COMMON CORE GROUTED 2. IF HEAD JOINT ALIGNS OVER THE FULL WALL HEIGHT, BREAK OPEN FACE SHELLS AND GROUT WALLS TOGETHER FULL HEIGHT, TYP AT ALL CORNERS AND INTERSECTIONS INTERSECTION CORNER STANDARD HOOK SEE NOTE 2 ADDED VERTICAL REINFORCEMENT, SIZE TO MATCH TYPICAL WALL REINFORCEMENT, TYPICAL VERTICAL REINFORCEMENT NOT SHOWN ONE HORIZONTAL BAR SHOWN, WALLS W/ 2 HORIZONTAL BARS SIM SIZE & SPACING OF L-BAR TO MATCH HORIZONTAL REINFORCEMENT TYP MLS MLS, TYP INTEGRALLY CONNECTED AT CORNERS & INTERSECTIONS OF MASONRY WALLS DO NOT CONTINUE JOINT REINF THRU CONTROL JOINT CONTINUE BOND BEAM REINF & BOND BEAM GROUT THRU CONTROL JOINT W/O INTERRUPTION PROVIDE CONTROL JOINTS IN STRUCTURAL MASONRY ONLY WHERE SHOWN ON THE STRUCTURAL OR ARCHITECTURAL PLANS VERTICAL REINFORCEMENT IN CELL EACH SIDE OF JOINT ON HEAD JOINT AT CONTROL JOINT CONTROL JOINT: HEAD JOINTS OF UNITS ALIGN AT CONTROL JOINT, NO MORTAR TYPICAL 2" CLEAR VERT REINF CENTERED (2) #4xCONT VERT REINF EACH FACE TYPICAL 2" CLEAR (2) #4xCONT 3" CLEAR 3" CLEAR (1) #5xCONT 3" CLEAR EQEQ NOTES: 1. ALL VERTICAL REINFORCEMENT SHALL BE CENTERED (UNO) IN GROUTED CELLS 2. PROVIDE `LADDER' TYPE HORIZONTAL JOINT REINFORCEMENT WITH 2-W1.7 (9 GA) WIRES (MIN) AT 16" OC, TYPICAL, AND AT 8" OC IN PARAPETS. 3. REFERENCE SPECIAL JAMB REINFORCEMENT NOTED IN "LARGE WALL OPENING" 4. ONLY STRUCTURAL WALLS ARE INCLUDED IN STRUCTURAL DRAWINGS. SEE ARCH FOR CMU PARTITIONS. REINF CENTERED REINF EACH FACE GROUT, TYPICAL SPACING 2 1/2" MW8-48(1) MASONRY WALL CMU THICKNESS REINF SPACING (1) CENTERED (2) EACH FACE #3 #4 #5 #6 #7 #8 #9 15 20 25 38 (NOTE 8) 52 (NOTE 8) 72 (NOTE 9) 81 (NOTE 9) 15 22 35 54 (NOTE 8) 63 (NOTE 8) 72 (NOTE 9) 81 (NOTE 9) #29 #25 #22 #19 #16 #13 #10 NOTES: 1. SMALLER BAR LAP LENGTH SHALL BE USED WHEN SPLICING DIFFERENT SIZED BARS 2. LAP LENGTHS SPECIFICALLY DETAILED ON DRAWINGS SHALL GOVERN INSTEAD OF SCHEDULED LAP LENGTHS 3. IF REINFORCING IS SPECIFIED AS EPOXY COATED, INCREASE LENGTHS BY 50% 4. MECHANICAL COUPLERS MAY BE USED IN LIEU OF ANY LAP LENGTH SHOWN. 5. WHEN LOW LIFT GROUTING IS USED, AND THE LAP LENGTH EXCEEDS THE GROUT LIFT HEIGHT (NOTED BY *), A MECHANICAL COUPLER IS REQUIRED IN LIEU OF LAPPED REINF. 6. VERTICAL REINF IN PILASTERS WITH AT LEAST 3 1/2" CLEAR SHALL BE SPLICED PER THE "REINF CENTERED" COLUMN 7. HORIZONTAL BOND BEAM RENF SHALL BE SPLICED PER THE "REINF AT FACE" COLUMN 8. REINF IN THESE SIZES SHALL NOT BE USED IN 6" MASONRY 9. REINF IN THESE SIZES SHALL NOT BE USED IN 6", 8", OR 10" MASONRY ENGLISH METRIC BAR SIZE MASONRY LAP SPLICE SCHEDULE REINFCENTERED8", 10", 12"MAS REINF ATFACE ANDAT BONDBEAMS f'm = 2000 psi REINFCENTERED 6" MAS 2" CLR S-201-1 14 13 S-201-1 WIDTH OPNG OPNG WIDTH S-201-1 7 S-201-1 19 TYP WALL SCHED AT CONC TYP AT HEAD AND SILL TYP AT JAMB TYP AT TOP & BOT TRACK NOTES: SEE FOR TYPICAL FASTENER INFO S-201-1 16 TYP BRIDGING 15/S-201-1 JAMB STUDS OPTION A OPTION B #10 TEK SCREW @ 12" OC TYP PROVIDE TRACK EA SIDE OF JAMB PACK TYPICAL JAMB STUDS 1/8 1 1/2-18 JAMB SCHEDULE OPNG WIDTH TYPICAL AREAS 6'-0" (2) 600S162-54 CORNER AREAS - NOTE: 1. SEE [S002] FOR CORNER AREAS HEADER AND SILL SCHEDULE OPNG WIDTH AND TYPE HEADER 6'-0" TYPE A (2) 600S162-43 AND (2) 600T125-43 SILL - HEADER - SILL - TYPICAL AREAS CORNER AREAS HEADER TRACKS ATTACH TO HEADER MEMBER W/(2) #10 TEK SCREWS @ 12" OC HEADER MEMBERS ATTACH TO TRACK W/#10 TEK SCREWS @ 12" OC EA SIDE JAMB STUD, SEE SCHEDULE L2x2x12 GAGE x TRACK WIDTH W/ 8 #10 TEK SCREWS T&B TRACK SEGMENT TO MATCH WALL STUD 600T125-54x0'-4 1/2", ATTACH TO JAMB STUD W/ 8#10 TEK SCREWS AND 8#10 TEK SCREW TO HEADER AT TYPE 'A' HEADER PAF IN CONCRETE P 1/3 SLAB THK P MAX = PAF COLD FORMED STL 3" MIN EDGE DISTANCE 4" MIN FASTENER SPACING d (MIN) BTWN FASTENERS COLD-FORMED STL d (MIN) TO EDGE OF COLD-F ORMED STEEL d (MIN) TO EDGE OF EDGE OF ATTACHED COLD-FORMED STL TEK SCREWS, PENETRATE 3 THREADS (MIN) PAST FINAL PLY, TYP TEK SCREW SIZE #10 #12 d 5/8" 3/4" TYP SCREW PLACEMENT OPTION 1 - CLIP ANGLE ATTACHMENT CLIP ANGLE BETWEEN 150U & STUD 150U50 150U50 OPTION 2 - DIRECT WELD ATTACHMENT OPTION 3 - FLAT STRAPS AND BLOCKING TRACK PIECE TO MATCH WALL STUD WIDTH, CLIP FLANGE AND BEND UP ATTACH FLAT STRAP TO TRACK TAUT FLAT STRAPS NO STUD DEPTH RESTRI CTI ON FORSTRAP BRACI NG OPTI ON d (8" MAX) 6" MAX FOR THI S OPTI ON ATTACH TRACK TO STUD STUD WEB AT CHANNEL LOCATION NUMBER OF FASTENERS REQUIRED TYP FRAMING 0.145"Ø PAF @ 16" OC JAMBS [2] 0.145"Ø PAFs PER JAMB STUD S-201-1 15 NOTES: 1. 1 1/4" EMBED REQUIRED FOR ALL PAFs 2. CUT AND BEND TRACK UP AT EXTERIOR JAMBS WHERE TRACK TERMINATES AT JAMB PACK 3 # 10 TEK SCREWS EA FLANGE 4 # 10 TEK SCREWS AT WEB (NOTE 2) d d INTERIOR DOOR JAMB W/(4) PAFS INTERIOR DOOR JAMB W/(6) PAFS INTERIOR WINDOW JAMB W/(4) PAFS INTERIOR WINDOW JAMB W/(6) PAFS EXTERIOR DOOR JAMB W/(4) PAFS EXTERIOR DOOR JAMB W/PROPRIETARY CLIP EXTERIOR WINDOW JAMB W/(4) PAFS EXTERIOR WINDOW JAMB W/(6) PAFS JACK STUD, TYP JAMB STUDS, TYP JACK STUD, TYP JAMB STUDS, TYP MIN FASTENER SPACING MIN FASTENER SPACING MIN EDGE DISTANCE MIN FASTENER SPACING MIN EDGE DISTANCE MIN FASTENER SPACING [TSN STIFFCLIP CL W/ (9) #12 TEK SCREWS AND (2) 1/4"Ø WEDGE- BOLTS BY POWERS FASTENERS] TOP CONNECTION DESIGN BY CONTR, SEE 19/Z5.40 FOR MIN CONNECTOR SPACING REQUIREMENTS B/PRIMARY STRUCTURE AT FRAMING 12" MAX [3/4"] SLIP SLIP CONNECTION 600 S 162 - 54 MATERIAL THICKNESS: IN 1/1000 INCHES MEMBER DEPTH: IN 1/100 INCHES FLANGE WIDTH: IN 1/100 INCHES TYPE: S = STUD OR JOIST SECTIONS T = TRACK SECTIONS U = CHANNEL SECTIONS F = FURRING CHANNEL SECTIONS TYPICAL ANNOTATION WALL SCHEDULE HEIGHT TYPICAL WALL AREAS 12'-6" 600S162-43 @ 16" OC WALL CORNERS 600S162-43 @ 12" OC TOP & BOT TRACK 600T125-43 NO SCALE 1 TYPICAL STRUCTURAL MASONRY WALL CORNER REINFORCING NO SCALE 2 TYPICAL MASONRY WALL CONTROL JOINT NO SCALE 3 TYPICAL MASONRY BOND BEAM NO SCALE 4 MASONRY WALL SCHEDULE - STRUCTURAL MW10-24(2) 10" NOTE 2 #5@24" (2) #4@48" #5@24" NO JOINT VERT HORIZ DOWELS MARK WALL THK REINFORCING GROUT SOLID STRUCTURAL MASONRY WALL SCHEDULE NO SCALE 5 MASONRY STRENGTH DESIGN LAP SPLICE SCHEDULE - 2000 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant EAST WING ENABLING 6/30/2017 2:54:00 PM 16.0188.S.01 S-201-1 MASONRY AND LIGHT GAUGE DETAILS 06/30/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 3/8" = 1'-0" 6 TYP CF WALL FRAMING 3" = 1'-0" 13 TYP CF JAMB SCHEDULE 1/2" = 1'-0" 14 TYP CF HEADER 3" = 1'-0" 15 TYP CF FASTENER DETAILS 1" = 1'-0" 16 TYP CF WALL BRIDGING 1 1/2" = 1'-0" 19 TYP CF BOTTOM TRACK TO CONC 3/4" = 1'-0" 20 SLIP TRACK AT TOP OF WALL NO SCALE 7 TYP CF WALL SCHEDULE 6/30/17 10/12/17