B17-0379_mech specs_1509483859.pdf
!ndoof Units: 3 / 2 to 4 Capacity. 36 / Htto 36 • Conneaabt.ap1City is not ac11.11f apKity. Total Pipe length: 85.0 / 492.0 feet Furthest Actual: 45.f) / 262.0 feet Furth~ Equiv.: 45.\J I 262.0 f~t (OtTeetion FactoR Outdoor Unit Capacity: 1.00 1.00 Temperature: 1.03 0.82 Piping Length: 0.99 1.00 Defrosting: 0.95 User Derate~ 0.94 0.94 Total Derate: 0.96 0.73 Additiooal ~erant 7.0 lb Total Refrigerant Amount: 17.6 lb Conditions \F) Cooling Indoor DB 80.0 Humidity 51.11% Indoor WB fil.O Outdoor DB 86.0 Heating tndoor DB 70.0 Outdoor DB· -7.0 Humidity 72.8% Outdoor WB -7.6 MXZ-4C36NAHZ 318 I 5/B PAC-MKA51BC Syslan 1 20.0ft ( 0) . . . Model Number Clg Total (Sens.) Pipe Dia. L1qurd I Gas ~ Htg.Total Pipe Length {Elbows) Group I Room I Tag Ref. 1/4 J 318 20.0ft ( 0) 1/4 J 3/8 20.0ft ( 0) 1/4 I 318 25.0ft ( 0) 0.0lt ( 0) 0.0ft { 0} 27.243 BTUJh (26.492 BTU/h) 25.911 BTUJh MSZ-GL 12NA-Ul '"'llJ.o!'il~·"' NIA f 1 I Living f FC-2 MSZ-GL12NA-U1 NIA f 21 Bedroom I FC-3 MSZ-GL 12NA-U1 9.086 BTU/h {8,832 BTU/h) 8.640BTU/h Est.. Cooling Discharge.Air Temp: 54. 4 Est. Heating Discharge Air Temp: 94.6 9.086 STU/h {8.832 BTIJ/h) Esl Cooling Discharge Air Temp: 54.4 8.640 BTUfh Est Heating Discharge Air Temp: 94.6 9.072 BTUlh (8.8Z7 BTU/h} Est. Cooling Discharge Air Temp: 54.4 8..631 BTU/h Est. Heating Olsd1111ge Air Temp-: 94 .6 NJA I 31 Master Bedroom I FC-1 Indoor Units: 3 I 2 to 4 Capacity: 36 / 18 to 36 • Connectable capacity is no< actual cap~. Total Prpe Length: 85.0 I 492.0 Furthest Actual: 45.0 I 262.0 furthest Equiv.: 45.0 I 262.0 Correction Factors Outdoor Unit Capacity: 1.00 1.00 Temperature: 1.03 D.82 Piping Length: 0.99 LOO Defrosting: -0,95 User Derate: 0.94 0.94 Total Derate: 0.96 0.73 Additional Refrigerant: 7.0 lb Total Refrigerant Amount 17.6 lb Conditions \F) Cooling feet feet feet Indoor DB 80.0 Humidity 5T.8% Indoor WB 67.0 Outdoor DB 86.0 Heating Indoor DB 7-0.0 Outdoor DB -7.0 Humidity 72.8% Outdoor WB -7.6 MXZ-4C36NAHZ 3/8 I 5/8 Symm 1 20.0ft ( O } Model Number Pipe Length {Elbows) Group J Room I Tao Ref. PAC-MKA51BC 27,243 BTU/h {26,492 BTU/h) Ctg.Total (Sens.I Htg Total L 25,911 BTU/h 1/4 I 3/S 20.0ft { 0) MSZ-Gll2NA-Ul 9,086 BTU/h {8,832 BTU!h) 8,6<\0BTU/h €st. Coaling Discharge Air Temp: 54..4 tst. Heating Dts;diarge Air Temp: 94.6· 1/4 I 3/8 20.0ft ( 0) 114 I 3/8 25.0ft ( 0 > O.Oft( 0 J O.Oft{ 0) NIA. J 1 I Living I FC-2 MSZ-Gl12NA-Ul NJA / 2 /Bedroom I FC-3 MSZ-Gl 12NA-U1 9,086 BTU/h (8,832 BTU/h) 8,640 BTU/h Est. Cooling Discharge Air Temp: 54.4 Est. He.isiing Disd1111'9t' Air Temp: 94.6 9,072 BTU/h (B,827 BTU/Ii) 8,631 BTU!h ~t. Cooling Discharge Air Temp: 54.A Est. Heating Drscharge Air Temp: 94.6 N/A / 3 I Master B~room I FC-1 - SUBMITTAL DATA: MSZ-GL 12NA-U1 • MITSUBISH M-S ERi ES 12,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS ~ELECTRIC System Reference: Indoor Unit MSZ-GL 12Ni\-U1 Wireless Remote Controller ACCESSORIES: Indoor Unit o Condensate Pump (BlueDiamond X87-711/721; 115/230V) o Condensate Pump (Sauemiann 5130-115/230; 115/230V) c Anti-Allergy Enzyme Filter (MAC-408FT-E) c Platinum Catalyst Deodorizing Filter (MAC-308FT-E) c Drain Pan Level Sensor (DPLS2) Controls ::: Wireless Controller (MHK1) ::. Wired Remote Controller PAR-32MAA (Requires MAC-3331F-E) ::: Wireless Interface for kumo cioud™ (PAC-WHS01WF-E) c Thermostat Interface (PAC-US444CN-1) Specifications are subject to change without notice. Date: SPECIFICATIONS: Heating at 47° F' Rabng Conditions per AHRI Standard. 'Cooling I Indoor: ao• F(27' C)DB 167' F(19" C)WB: O\Jldooc 95' F(35' C)DB 175' F(24' C)WB 'Heating at 47°F I Indoor 70' F (21' C)DB /60' F (16' C)WB: Outdoor 47' F (8' C)DB / 43' F (6' C)'NB For data on specific indoor units (all ducted, all non--ducted, and both ducted and non--ducted) combinations, see the MXZ Technical and Service Manual. Applications should be restricted to comfort coot!ng only: equipment cooling apptications are not recommended for low ambient temperalure cond1Uons. Minimum Circuit Ampacity (MCA) 208 I 230V, 1-Phase, 60 Hz A l:!!.Mjif,M@@fi._:.:~~J_?:~_6 _______________________ ~ l :!!.MjHMN·Mf ll._w __ ____,jL.3_0 ______________ ~ Heating External Dimensions (H xWx D) Gas (Low Pressure) ln.(mm) 19-22-30-37-43 I 11-5/8 x 31-7/16 x 9-1/8 ! (295 x 798 x 232) \ 22 (10) © 2016 Mitsubishi Electric US, Inc. DIMENSIONS: MSZ·GL 12NA·U1 MSZ-GL 12NA-U1 !.:.ill Z.)110, '--" 3;4 ·----...-, ··~ n~ ~ I I !nstol !o! 100 3!.]/16 I 30 15/16 : 1/4 f I I§ Indoor uni I FORM# MSZ-GL 12NA-U1 FOR MXZ-C MULTI-ZONE SYSTEMS-201611 Specifications are subject to change without notice. 0·118 .s·u8 Unit: in. (mm) J/!6•13/i& Obion hole -'--'-'3"-.. -"; ''""8 "'' -------==!-.. iJ· 51 I & 13 9/i 6 Air in , al I hole •2-9/16 !< ....... 0 Air out lnsu!at!on .[ Liquid line C: Gas hne Drain hose D I ol e ~~·-~ )/ 16 r:..:...:.. Drain ho1e 01-318 O.D a1i4 19 -11/16 (Flared connection 01/4) •31816-15116 (Flared ::om:ecton. e3i8 (GL06/0S/12NA). 01!.2 iGL15NA)i Insulation 1111-1/8 0.0 Connected part o5/8 0.0 • MITSUBISHI l\a.ELECTRIC COO LING & H EATING 1340 Satellite Boulevard. Suwanee. GA 30024 Toll Free: 800-433-4822 www.mehvac.com A.~ CERTIFIED. ~ =k':!~.IJ~ ~-...... ,. .-..-.. •··--lntertek © 2016 Mitsubishi Electric US, Inc. •': SUBMITTAL DATA: MXZ-4C36NAHZ • lllllTSUBISHI M-S ERi ES MULTI-INDOOR INVERTER HEAT·PUMP SYSTEM .... ELECTRIC ----------~------------ System Reference: I I re Ouldoor Unit: MXZ-4C36NAHZ ACCESSORIES o Three-port Branch Box (PAC-MKA30BC) u Five-port Branch Box (PAC-MKA50BC) o Distribution Pipe for Flare Connection Date: (MSDD-50AR; necessary for installing two branch boxes) ,J Distribution Pipe for Brazed Connection (MSDD-50BR; necessary for installing two branch boxes) o 3/8" x 1/2" Port Adapter (MAC-A454JP) CJ 1 /2" x 3/8" Port Adapter (MAC-A455JP) ::; 1 /2" x 5/8" Port Adapter (MAC-A456JP) "J 1/4" x 3/8" Port Adapter {PAC-493PI) u 3/8" x 5/8" Port Adapter (PAC-SG76RJ) :i Airflow Guide (PAC-SH96SG-E) (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) Specifications Unit Type Rated Capacity Btu/h Cooling* Capacity Range Btu/h (Non-ducted I Ducted) Rated Total Input w Rated Capacity Btu/h Heating at 47°F* Capacity Range Btu/h (Non-ducted I Ducted) Rated Total Input w Rated Capacity Btu/h Heating at 17°F* Maximum Capacity Btu/h (Non-ducted/Ducted) Rated Total Input w Heating at 5°F* Maximum Capacity Btu/h Power Supply Voltage, Phase, Hertz Electrical Requirements Recommended Fuse/Breaker Size A MCA A Indoor -Outdoor S1-S2 v Voltage Indoor -Outdoor S2-S3 v Compressor Fan Motor (ECM) F.L.A. Sound Pressure Level Cooling dB(A) Heating External Dimensions (H x W x D) In/mm NetWeiqht Lbs I kg External Finish Refrigerant Pipe Size 0.0. Liquid (High Pressure) In/mm Gas (Low Pressure) Max. Refrigerant Line Length Ft/m Max. Pipini:i Length between outdoor unit and branch boxes Ft/m Max. Piping Length after branch box Ft/m Max. Total Piping Length between branch boxes and indoor units Ft/m Max. Refrigerant Pipe Height If IOU is Above ODU Ft/m Difference If IOU is Below ODU Connection Method Refrigerant • Rating Conditions per AHRI Standard: Cooling I Indoor 800F (27° C) DB/67°F (19° C) 'Ml Cooling I Outdoor: 95° F (35° C) DB / 75° F (24° C) \NB HeaUng at 47°F I Indoor. 700 F (21" C) DB He.Ung at 47°F I Outdoor 47° F (8" C) DB/ 43° F (6° C) \M3 Specifications are subject to change without notice. Model Name MXZ-4C36NAHZ 36,000 / 36,000 6,000 -36,000 2,570 / 3, 180 45,000 / 45,000 7,200 -45,000 3,340 I 4,250 34,000 / 36,000 45,000 I 45,000 3,500 / 4,590 45,000 208 / 230V, 1-Phase, 60 Hz 50 42 AC 2081230 DC±24 Hermetic 0.4+0.4 49 53 52-11/16X41-11/32X13+1 1338x1050 x 330+25 276/125 Munsell No. 3Y 7.8/11 3/8 / 9.52 5/8115.88 492 (150) 180 (55) 82 (25) 311 (95) 131 (40) 164 (50) Flared/Flared R410A Heating at 17° FI Indoor 700 F (21° CJ DB Heating at 17" FI Outdoor: 17° F (-8" C) DB 115° F (-9° C) IM3 © 2017 Mitsubishi Electnc US, Inc.