Loading...
HomeMy WebLinkAboutB17-0384_300 E Lionshead Apt301 Abatement clean check 20170914_1505848500.pdf 4-1 Environmental Development and Training ACM LLC. P.O. Box 452 Wheat Ridge, Colorado Phone 303-638-3778 edtacmllc@icloud.com September 14, 2017 Jesus Rivas Environmental Connection LLC Site: 300 Lionshead Circle in Vail, Colorado. Unit 301. Clearance conducted after abatement of identified asbestos containing ceiling, and wall material from containment area. Abatement was conducted prior to planned renovation and repair. Task 1 - Field Work: Project Scope of Work Conducted during Air Monitoring: 1. Contractor conducted abatement according to applicable Colorado Regulation 8, for a removal containment system in: OSHA: required containment system, and negative pressure system. 2. Completion of final inspections and air monitoring. 2.0 SAMPLE COLLECTION METHODS EDT ACM LLC used NIOSH method 7400, 40 CFR 763 AHERA and OSHA 29CFR 9010 methodology during activities to support abatement activity: 4-2 ENVIRONMENTAL AIR SAMPLES ADJACENT TO THE WORK AREA: Environmental sampling was conducted post abatement activity. The air samples were collected on 25 mm cassettes with 0.8u filters and analyzed by R2 Analytical according to NIOSH method 7400. All environmental samples were less than or equal to 0.01 f/cc (fibers per cubic centimeter of air sampled). No fiber concentrations were observed in excess of the OSHA 29CFR 9010 or the CHPHE Allowable Asbestos Level (MAAL). FINAL AIR SAMPLES: Clearance air sampling was conducted according to Colorado Regulation 8. All of the clearance samples collected within the work area were less than 0.01 F/CC, (fibers per Cubic Centimeter. No concentrations were observed in excess of the Maximum Allowable Asbestos Level (MAAL). 3.0 CONCLUSIONS Based on observations during the site visit, and the laboratory analytical results, EDT LLC ACM concludes the following: All Environmental and Final work Area or Clearance Air samples collected outside and inside the regulated work area clearance criteria indicated; fiber concentrations less than or equal to 0.01 f/cc (fibers per cubic centimeter of air sampled). No fiber concentrations were observed in excess of the Maximum Allowable Asbestos Level (MAAL) per CDPHE. Based on sampling and analysis results attached, no further action is recommended or required for this phase of the project for the impacted areas. As additional abatement items are addressed environmental and clearance air monitoring should be performed according to Colorado and EPA Regulations. 4-3 4.0 LIMITATIONS Limitations Environmental Development and Training ACM LLC prepared this report, for the exclusive and present use of Environmental Connection LLC. This report addresses certain physical characteristics of the site with regards to the release or presence of asbestos in limited, client determined, areas only. These services were performed in a manner consistent with practices common in the environmental health profession. The information and conclusions provided herein are valid only with respect to the specific locations and analytes investigated at the time this report was prepared. The findings, conclusions, and recommendations presented here are based on information available at the time the site was evaluated. In the event of any reuse or publication of any portion of this report, Environmental Development and Training ACM LLC shall not be liable for damages arising out or such reuse of publication. Any reuse a third party makes of this report, or any reliance on or decisions made are the responsibility of such third party. Environmental Development and Training ACM LLC accepts no responsibility for damages, if any, suffered by any third party as the result of decisions made or actions taken based on this report. Kris T. Wilson Kris Thomas Wilson President Environmental Development and Training ACM LLC Environmental Development and Training ACM LLC. Phone 303-638-3778 4-4 AIHA Laboratory Certification #156492 Colorado Laboratory Certification #14903 R2 Analytical Job Number 30009142017-1 Client 300X-1 Client Project Number 300DX-1 Date/ Time Logged In 09/14/2017 2240 hrs Analysis Due 2 Hour Rush Analysis Requested NIOSH 7400 A- Rules f/mm2 f/cc & f/mm2 f/cc R2 Sample # R2 LAB ID Volume(L) #Fields #Fibers Fiber Density Detection Limit Fiber Concentration X1-BL-01 BL-1 0 100 0 - - - X1-BL-02 BL-2 0 100 0 - - - X1-CLR-03 300C1-3 553 100 5.0 0.006 0.005_BDL X1-CLR-04 300C1-4 553 100 6.5 0.006 0.006_BDL X1-CLR-05 300C1-5 553 100 2.5 0.006 0.003_BDL X1-CLR-06 3000C1-6 553 100 3.0 0.006 0.003_BDL X1-CLR-07 3000C1-7 553 100 4.5 0.006 0.004_BDL BDL – Below Detection Limit Bob Regan 210-1349 5177 South Ventura Way Centennial, CO 80015 R2 Analytical