Loading...
HomeMy WebLinkAboutB17-0390_G-001-02_1511976150.pdf lik" I/4 General Sheet Locationc ire e,7 CV 4N, 4tir:111 LU Lu -41-1120)11:1- 1. L' 1. THE CONTRACT DOCUMENTS IN THEIR ENTIRETY ARE THE Ui Lu �Q • RESPONSIBILITY OF ALL TRADES. WHERE REQUIREMENTS ARE SHOWN Q Q Q Q 11/29/17 IN ONE SECTION OF THE SPECIFICATIONS OR DRAWINGS BUT NOT LU Z a W Z a ANOTHER,THE CONTRACTOR OR SUBCONTRACTOR IS NOT RELIEVED U Q Z Z W Q Z Z FROM PROVIDING COMPLETELY FINISHED AND PROPERLY FUNCTIONING Z a Z0 Z0 Z 0 Z Z SYSTEMS. 2. THE CONTRACTOR /SUBCONTRACTOR SHALL BE FULLY RESPONSIBLE D D 5 5 D D 5 5 PROJECT FOR THE LAYOUT AND COORDINATION OF DIMENSIONS IN THE FIELD CO V) W W (1) Cl) W W THAT ESTABLISH WORK POINTS FOR THEIR WORK AND VARIOUS NUMBER SHEET a) r NUMBER SHEET v) Cl) TRADES. Ia _ lu 3. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, /-? rP BUT REQUIRED FOR THE PROPER EXECUTION, INSTALLATION, OR 01 General 14 Mechanical Demolition LIONSHEADCIR PERFORMANCE OF THE WORK,SHALL BE PROVIDED BY THE G-001-1 COVER PERMIT 06/30/17 MD-107-75 ROOF MECHANICAL DEMO PLAN-ENABLING PERMIT 06/30/17 . IIII a - CONTRACTOR /SUBCONTRACTOR. G-001-2 SHEET INDEX AND PROJECT DATA PERMIT 06/30/17 ASI 02 09/25/17 15 Mechanical 1 FRONTAGE RD. 4. ALL ITEMS REQUIRING A METHOD OF PROCEDURE APPROVAL SHALL BE 02 Life Safety M-001-75 MECHANICAL LEGENDS& NOTES PERMIT 06/30/17 111 II aSUBMITTED FOR REVIEW 21 DAYS IN ADVANCE. LS000-1 CODE ANALYSIS PERMIT 06/30/17 M-002-75 MECHANICAL SCHEDULES AND DETAILS PERMIT 06/30/17 �� 1111 , 5. THE CONSTRUCTION SITE IS TO BE KEPT CLEAN AND FREE OF DEBRIS. W.MEADOWS 11 111 I. THE CONTRACTOR /SUBCONTRACTOR IS RESPONSIBLE FOR ALL LS101-1 LIFE SAFETY PLAN LEVEL 1 PERMIT 06/30/17 EE ASI 01 09/26/17 M-090-75 02 ENCLOSURE MECHANICAL SITE PLAN PERMIT 06/30/17 IIPHASES OF SECURING, HANDLING,TRANSPORTING AND DISPOSING OF LS101-2 LIFE SAFETY PLAN-LEVEL 1 -OCCUPANCY &USE PERMIT 06/30/17 EE ASI 01 09/26/17 M-100-75 MECHANICAL-PLUMBING SITE PLAN-ENABLING PERMIT 06/30/17 EE ASI 01 09/26/17 DEBRIS. LS201A-1 INTERIM LIFE SAFETY PLAN-AREA A-SEQ 1 PERMIT 06/30/17 EE ASI 01 09/26/17 M-101-75 LEVEL 1 HVAC AND PIPING PLANS-ENABLING PERMIT 06/30/17 EE ASI 01 09/26/17 Mow y 11111111 ■■ 6. THE CONTRACTORS /SUBCONTRACTORS SHALL NOT SHUT OFF OR LS201A-2 INTERIM LIFE SAFETY PLAN-AREA A-SEQ 2 PERMIT 06/30/17 M-102-75 LEVEL 2 HVAC AND HVAC DEMO PLAN-EAST WING ENABLING PERMIT 06/30/17 EE ASI 01 09/26/17 BEAVER DAM INTERRUPT ANY SYSTEMS OR SERVICES WITHOUT FIRST COORDINATING LS201A-3 INTERIM LIFE SAFETY PLAN-AREA A-SEQ 3 PERMIT 06/30/17 EE ASI 01 09/26/17 M-103-75 FUEL OIL TANK PLAN DETAIL AND SCHEDULE PERMIT 06/30/17 0 WITH THE OWNER. 03 Civil M-107-75 ROOF MECHANICAL PLAN-ENABLING PERMIT 06/30/1744 7. THE CONTRACTOR /SUBCONTRACTORS SHALL COORDINATE WITH THE FORESTIIII = = = �� C010 GENERAL NOTES PERMIT 06/30/17 EE ASI 01 09/26/17 16 Electrical Demolition OWNER TO IDENTIFY AND PROTECT EXISTING STRUCTURE, Roc • ELECTRICAL/DATA/TELECOM SYSTEMS,UTILITIES, SURFACES AND C110 EXISTING CONDITIONS PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 ED-111-75 LEVEL 1 POWER DEMOLITION PLAN PERMIT 06/30/17 KLEoGe xt ili W • iiimor FINISHES WHICH ARE TO REMAIN.ANY DAMAGED DURING C111 EXISTING CONDITIONS PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 ED-112-75 LEVEL 2 POWER DEMOLITION PLAN PERMIT 06/30/17 1� gym.. r-P 1 1 111 CONSTRUCTION SHALL BE REPAIRED BY THE C120 DEMOLITION PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 ED-113-75 ROOF DEMO POWER PLAN-ENABLING PERMIT 06/30/17 M/c< -- CONTRACTOR/SUBCONTRACTOR. SFS s Mq CRFFK 1 ! ! 7 v 1\v 1 1 1 1 8. DELIVERY AND STORAGE OF CONSTRUCTION MATERIALS AND C121 DEMOLITION PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 17 Electrical <cRFFk Ro C TC EQUIPMENT (STAGING AREAS) SHALL BE COORDINATED WITH THE C122 DEMOLITION PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-001-75 ELECTRICAL LEGENDS& NOTES PERMIT 06/30/17 Ro ` v 1 1 • ` _ I ..• OWNER AND SHALL NOT TO INTERFERE WITH HOSPITAL TRAFFIC. C123 02 ENCLOSURE DEMOLITION PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-011-75 ELECTRICAL ONE-LINE DIAGRAM -WEST NORMAL ENTRANCE PERMIT 06/30/17 9. THE CONTRACTOR /SUBCONTRACTOR SHALL TAKE CARE TO PROTECT C130 EROSION CONTROL PLAN PERMIT 1 06/30/17 EE ASI 01 09/26/17 E-012-75 ELECTRICAL ONE-LINE DIAGRAM -WEST NORMAL POWER PERMIT 06/30/17 2901 Blake Street, Suite 100 ALL NEWLY INSTALLED MATERIALS AND FINISHES UNTIL WORK IS C200 SITE LAYOUT AND RECONSTRUCTION PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-013-75 ELECTRICAL ONE-LINE DIAGRAM -WEST EMERGENCY POWER PERMIT 06/30/17 Denver Denver, CO 80205 FORMALLY ACCEPTED BY THE ARCHITECT OR THE OWNER'S C201 SITE LAYOUT AND RECONSTRUCTION PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-014-75 ELECTRICAL ONE-LINE DIAGRAM -WEST CRITICAL AND EQUIPMENT PERMIT 06/30/17 303.861.8555 REPRESENTATIVE AND TRANSFERRED TO THE OWNER C202 SITE LAYOUT AND RECONSTRUCTION PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-015-75 ELECTRICAL ONE-LINE DIAGRAM - EAST NORMAL POWER PERMIT 06/30/17 10. ALL PENETRATIONS THROUGH FLOORS,WALLS AND RATED ASSEMBLIES Consultant C203 02 ENCLOSURE SITE LAYOUT PERMIT 06/30/17 EE ASI 01 09/26/17 E-016-75 ELECTRICAL ONE-LINE DIAGRAM -EAST EMERGENCY POWER PERMIT 06/30/17 AS WELL AS ALONG SLAB PERIMETERS AND SEPARATION WALL PERIMETERS, SHALL BE SEALED AND PROTECTED WITH U.L.APPROVED C210 SOUTH GRADING PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-017-75 ELECTRICAL ONE-LINE DIAGRAM - EAST TEMPORARY SERVICE PERMIT 06/30/17 SAFETY ASSEMBLIES AND/OR PROTECTIVE DEVICES HAVING THE SAME C211 WEST GRADING PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-100-75 ELECTRICAL SITE PLAN-ENABLING PERMIT 06/30/17 Project OR GREATER TESTED RATING AS THAT REQUIRED FOR THE ASSEMBLY C212 INTERIM GRADING PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-111-75 LEVEL 1 POWER PLAN-ENABLING PERMIT 06/30/17 BEING PENETRATED. ALL PENETRATIONS SHALL BE PROTECTED TO C213 OXYGEN BUNKER GRADING PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-112-75 LEVEL 2 POWER PLAN-ENABLING PERMIT 06/30/17 MAINTAIN FIRE RATED ASSEMBLY INTEGRITY. C300 UTILITY PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-113-75 LEVEL 3 POWER PLAN-ENABLING PERMIT 06/30/17 11. PROVIDE ELECTROLYTIC PROTECTION /ISOLATION BETWEEN ALL ARCHITECT OWNER DISSIMILAR METALS,AND BETWEEN TREATED WOOD AND METALS TO C301 UTILITY PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 E-114-75 ROOF POWER PLAN-ENABLING PERMIT 06/30/17 Davis Partnership Architects Vail Valley Medical Center PREVENT ELECTROLYTIC REACTION AND/OR CORROSION. C320 SANITARY SEWER MAIN PLAN AND PROFILE PERMIT 06/30/17 EE ASI 01 09/26/17 E-301-75 ELECTRICAL PANEL SCHEDULES PERMIT 06/30/17 12. ALL WOOD,EXCEPT ARCHITECTURAL WOODWORK, USED ON THIS C322 SANITARY SEWER MAIN PLAN AND PROFILE PERMIT 06/30/17 EE ASI 01 09/26/17 E-302-75 ELECTRICAL PANEL SCHEDULES PERMIT 06/30/17 2901 Blake Street 180 S Frontage Road W PROJECT SHALL BE FIRE RETARDANT, NON-COMBUSTIBLE TREATED AS C330 WATER MAIN&SERVICE PLAN PROFILE PERMIT 06/30/17 EE ASI 01 09/26/17 Suite 100 Vail, CO 81657 APPROVED FOR USE BY THE LOCAL CODE AUTHORITIES. NO WOOD C400 EROSION CONTROL DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 Denver, CO 80205 (WHETHER TREATED OR NOT) SHALL BE USED WITHIN THE CEILING P. 303.861.8555 PLENUM SPACE. C401 EROSION CONTROL DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 13. THE CONTRACTOR /SUBCONTRACTOR SHALL PROVIDE ADEQUATE C403 EROSION CONTROL DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 THE FOLLOWING DOCUMENT AND SHEET LIST IS PROVIDED FOR REFERENCE: Scott Nevin BLOCKING,BACKING OR STRUCTURAL SUPPORT AS REQUIRED TO 105 Landscape scott.nevin@davispartnership.com PROPERLY INSTALL ALL MOUNTED ASSEMBLIES, INCLUDING ALL L-000 ABBREVIATIONS AND SYMBOLS PERMIT 06/30/17 DEPARTMENT OF TRANSPORTATION ATTACHED EQUIPMENT(OWNER AND CONTRACTOR FURNISHED ITEMS), STATE OF COLORADO L-100 PHASE 1 SITE MATERIALS AND LAYOUT PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 PLUMBING FIXTURES, MILLWORK, AND CASEWORK. NOTE: ALL FRAMING L-101 SITE AND LANDSCAPE PLAN ASI 02 09/26/17 TOWN OF VAIL, EAGLE COUNTY CIVIL ENGINEER OWNER REPRESENTATIVE OR CONCEALED BLOCKING SHALL BE METAL BETWEEN STUDS AS IS SOUTH FRONTAGE ROAD IMPROVEMENTS RECOMMMENDED FOR WALL MOUNTED ITEMS. REFER TO THE A-700 L-150 PLANTING PLAN PERMIT 06/30/17 Martin/Martin, Inc. Project One Integrated Services SERIES DRAWINGS FOR FUTHER INFORMATION. L-500 SITE DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 BY MARTIN / MARTIN 0101 Fawcett Rd. 88 Inverness Cir E 14. WHERE FIRE EXTINGUISHER CABINETS,ELECTRICAL PANELS OR OTHER L-550 PLANTING DETAILS PERMIT 06/30/17 FINAL UPDATED DOCUMENTS ISSUED 08/21/2017 Suite 260 Building G, Suite 101 -- EQUIPMENT OR DEVICES ARE RECESSED IN FIRE RATED PARTITIONING 06 Structural Avon, Co 81620 Englewood, CO 80112 AND/OR SOUND RATED PARTITIONING, MODIFY PARTITION S-001-1 GENERAL NOTES PERMIT 06/30/17 EE ASI 01 09/26/17 SHEET LIST: '} CONSTRUCTION TO PROVIDE CONTINUOUS ENCLOSURE FOR 1. TITLE SHEET P. 970.926.6007 P. 303.917.7507 UNINTERRUPTED ASSOCIATED FIRE RATING AND/OR SOUND RATING. S-001-2 GENERAL NOTES PERMIT 06/30/17 2. CDOT STANDARD SHEET LIST Mark Luna Chris Knight 1 15. ALL ROOMS OR AREAS WITH CEILINGS OPEN TO STRUCTURE ARE TO S-002-1 QUALITYASSURANCE PERMIT 06/30/17 3. CDOT GENERAL NOTES \ -- F CO O mluna@martinmartin-mtn.com chrisk@projectoneis.com HAVE METAL WALL GRILLS FOR AIR DUCT OPENINGS OR AT OPEN AIR S-002-2 QUALITY ASSURANCE PERMIT 06/30/17 4. GENERAL NOTES TRANSFERS. COORDINATE SIZE OF GRILLE WITH MECHANICAL S-101-B LEVEL 1 -RAMP PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 5. GENERAL NOTES 7a� N... \ DRAWINGS AND AIR FLOW REQUIREMENTS. S-101-C LEVEL 1 -AMBULANCE BARN PLAN PERMIT 06/30/17 6. TOWN OF VAIL GENERAL NOTES MICHAEL 16. METAL FRAMING STUD SPACING MAY VARY AT LOCATIONS RECEIVING 7. TOWN OF VAIL GENERAL NOTES MECHANICAL,ELECTRICAL, PLUMBING CODE CONSULATANT MOISTURE RESISTANT GYPSUM BOARD. INSTALL FRAMING AT WALLS, S-101-D LEVEL 1 -OXYGEN ENCLOSURE PLANS PERMIT 06/30/17 EE ASI 01 09/26/17 8, WATER NOTES Cator Ruma &Associates Co Advanced Consulting Engineers 1 * NEVIN HARD CEILINGS AND SOFFITS PER MANUFACTURER'S S-103-A LEVEL 3- ED ROOF PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 9. ABBREVIATIONS AND LEGEND 896 Tabor Street 3900 S.Wadsworth Blvd. RECOMMENDATIONS. REFER TO SPECIFICATIONS FOR A DISCRIPTION S-200-1 CONCRETE DETAILS PERMIT 06/30/17 10. OVERALL PLAN OF THE LOCATIONS TO RECEIVE MOISTURE RESISTANT GYPSUM BOARD S-201-1 MASONRY AND LIGHT GAUGE DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 11. UTILITY PLAN Lakewood, CO 80401 Suite 595 C1 C) INCLUDING BUT NOT LIMITED TO LOCATIONS ADJACENT TO PLUMBING S-202-A ED ROOF DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 12. UTILITY PLAN P. 303.232.6200 Lakewood,CO 80235 5+ DAf � FIXTURES. 13. UTILITY PLAN P. 720.981.4150 17. THE GC SHALL CARRY FIRE WATCH COSTS TO PROVIDE PERSONNEL PER S-203-B RAMP DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 14. WATER PLAN NFPA. S-204-D 02 ENCLOSURE DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 15. UTILITY DETAILS Wayne Trader Masoud Sabounchi WM7117 18. THE OWNER WILL BE REQUIRED TO SIGN OFF ON ROUGH IN AND 08 Architectural Demolition 16. UTILITY DETAILS wtrader@catorruma.com masoud@acecode.com ARCHITECTURAL DEVICES BEFORE PROCEEDING. SEE SPECIFICATION 01 A-000-1 ABBREVIATIONS &SYMBOLS PERMIT 06/30/17 17. EROSION CONTROL PLAN Issuance 4000 FOR MORE INFORMATION. 18. TRAFFIC CONTROL CONCEPT 19. GC TO PROVIDE ICRA COMPLIANCE PLAN TO OWNER FOR APPROVAL AD101A-1 ENLARGED DEMOLITION FLOOR PLAN-AREA A PERMIT 06/30/17 EE ASI 01 09/26/17 PRIOR TO COMMENCING WORK. AD151A-1 ENLARGED DEMOLITION REFLECTED CEILING PLAN-AREA A PERMIT 06/30/17 STRUCTURAL ENGINEER MEDICAL EQUIPMENT PERMIT 06/30/17 09 Architectural Martin/Martin, Inc. Mitchell Associates A-101-0 OVERALL SITE PLAN PERMIT 06/30/17 EE ASI 01 09/26/17 12499 W.Colfax Ave. 630 Dundee RD Suite 340 A-101-1 OVERALL FLOOR PLAN-LEVEL 1 PERMIT 06/30/17 EE ASI 01 09/26/17 Lakewood, CO 802015 Northbrook, IL 60062 Revisions Date A-101A-1 ENLARGEDANNOTATION AND DIMENSION FLOOR PLAN-AREA A PERMIT 06/30/17 EE ASI 01 09/26/17 P. 303.431.6100 360.798.7653 A-101B-1 ENLARGED ANNOTATION AND DIMENSION FLOOR PLAN-AREA B PERMIT 06/30/17 EE ASI 01 09/26/17 A-101C-1 ENLARGEDANNOTATION AND DIMENSION FLOOR PLAN-AREA C PERMIT 06/30/17 EE ADDENDUM 1 08/28/17 1 Shane McCormick Matt Gibbs EE ASI 01 09/26/17 2 IA-101D-1 ENLARGED ANNOTATION AND DIMENSION FLOOR PLAN-AREA D PERMIT 06/30/17 EE ASI 01 09/26/17 smccormick@martinmartin.com mgibbs@mitchellplanning.com A-107-1 OVERALL FLOOR PLAN- ROOF PERMIT 06/30/17 ASI 02 09/25/17 3 A-151-1 OVERALL REFLECTED CEILING PLAN-LEVEL 1 PERMIT 06/30/17 A-151A-1 ENLARGED REFLECTED CEILING PLAN-LEVEL 1 -AREA A& B PERMIT 06/30/17 EE ASI 01 09/26/17 INTERIOR DESIGNER LANDSCAPE A-200B-1 EXTERIOR ELEVATIONS AND PERSPECTIVES -FUEL TANK AND RAMP PERMIT 06/30/17 EE ASI 01 09/26/17 Davis Partnership Architects Davis Partnership Architects A-200D-1 EXTERIOR ELEVATIONS AND PERSPECTIVES -02 ENCLOSURE PERMIT 06/30/17 EE ASI 01 09/26/17 2901 Blake Street 2901 Blake Street A-310-1 WALL SECTIONS AND PERSPECTIVES PERMIT 06/30/17 EE ASI 01 09/26/17 Suite 100 Suite 100 A-510-1 EXTERIOR DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 Denver, CO 80205 Denver, CO 80205 A-511-1 EXTERIOR DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 P. 303.861.8555 P. 303.861.8555 A-512-1 EXTERIOR DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 A-720-1 DOOR SCHEDULE,PARTITION TYPES, AND DETAILS PERMIT 06/30/17 EE ASI 01 09/26/17 Janette Ray Lynn Moore A-720-2 EXTERIOR BUILDING SYSTEMS PERMIT 06/30/17 EE ASI 01 09/26/17 Janette.ray@davispartnership.com lynn.moore@davispartnership.com A-721-1 FRAMING DETAILS PERMIT 06/30/17 Project Information N- 1.0 U) CO Z Co O 0 U I- V J z 'ca p co > 2 a w W CD o 0 ? o Z I ICT) l' wa C to o Q w co 0 co Sheet Information Sheet Title: SHEET INDEX AND PROJECT DATA Sheet Number: m G . 001 . 2a N_ d 7 N- n oO N DPA Project: 15924.00 COPYRIGHT2017 -DAVIS PARTNERSHIP,