Loading...
HomeMy WebLinkAboutB18-0048_approved documents_1522697777.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B18-0048 Issued: 04/02/2018 TOWN OF VAIL Property Information Address: 660 LIONSHEAD PL (210107203999) ( 210107203999 ) Unit #: Parcel Number: 210107203999 Legal Description: Contacts Contact Type: Applicant Full Name: matt anderson Address: 51 Eagle Road 51 Eagle Road Avon, CO 81620 Phone: 9704713459 Contact Type: Property Owner Full Name: Common Area Address: Phone: None Contact Type: Site Superintendent Full Name: Jeff Rice Address: CO Phone: 970-309-5974 Contractor Contractor Type: General Company: R.A. Nelson & Associates Inc State License #:Phone: 970-949-5152 Project Information Project Name: Lion Square Lodge South 2018 Project Description: THE PROJECT INCLUDES INTERIOR UPGRADES TO EXISTING CONFERENCE ROOMS AT LION SQUARE LODGE INCLUDING NEW CEILING FINISHES, LIGHTING, INTERIOR TRIM, AND ROOM DIVIDERS. AREA OF EXISTING COLUMBINE & GORE CREEK ROOMS = 2,350 SF (NO CHANGE TO EXISTING SF) AREA OF EXISTING WILDWOOD CONFERENCE ROOM AND PREFUNCTION AREA = 2,883 SF (NO CHANGE TO EXISTING SF). Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$3,514.00 Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$2,284.10 Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$10,978.26 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$1,460.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$365.00 Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Total Paid:$18,611.36 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. PERMIT FEE RECEIPT Case # B18-0048 Date Printed: 03/07/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0048 Status: Created Permit Number: Date Started: 02/27/2018 Permit Type: Construction Subcases Multi-Family Lot Number: 1 Property: 660 LIONSHEAD PL (210107203999) (210107203999) Contacts Contact Type: Applicant Company Name: RA Nelson Full Name: matt anderson Address: 51 Eagle Road 51 Eagle Road Avon, CO 81620 Email: manderson@ranelson.com Contact Type: Property Owner Full Name: Common Area Address: Permit Fees Fee Information Account Amount Plan Review 001-0000.31123.00 $2,649.10 Payment Information Date Paid Payment Type Amount Plan Review 03/07/2018 Check $2,649.10 Paid By: Lion Square Lodge - Notes: ck # 9773 FEE TOTAL $2,649.10 AMOUNT PAID $2,649.10 BALANCE DUE $15,962.26 03/07/2018 - 11:48:53 AM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 1 / 1 PERMIT FEE RECEIPT Case # B18-0048 Date Printed: 04/02/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0048 Status: Approved Permit Number: Date Started: 02/27/2018 Permit Type: Construction Subcases Multi-Family Lot Number: 1 Property: 660 LIONSHEAD PL (210107203999) (210107203999) Contacts Contact Type: Applicant Company Name: RA Nelson Full Name: matt anderson Address: 51 Eagle Road 51 Eagle Road Avon, CO 81620 Email: manderson@ranelson.com Contact Type: Property Owner Full Name: Common Area Address: Contact Type: Site Superintendent Company Name: Ra Nelson Full Name: Jeff Rice Address: CO Email: jrice@ranelson.com Permit Fees Fee Information Account Amount Permit Fee 001-0000.31111.00 $4,974.00 Construction Tax 110-0000.31060.00 $10,978.26 Will Call Fee 001-0000.31128.00 $10.00 Payment Information Date Paid Payment Type Amount Will Call Fee 04/02/2018 Check $10.00 Paid By: Lion Square Lodge and Conference Center - Notes: 9800 - Lion Square Lodge and Conference Center Permit Fee 04/02/2018 Check $4,974.00 Paid By: Lion Square Lodge and Conference Center - Notes: 9800 - Lion Square Lodge and Conference Center Construction Tax 04/02/2018 Check $10,978.26 Paid By: Lion Square Lodge and Conference Center - Notes: 9800 - Lion Square Lodge and Conference Center FEE TOTAL $15,962.26 AMOUNT PAID $15,962.26 BALANCE DUE $0.00 04/02/2018 - 1:32:08 PM - Generated by: dcouch75 South Frontage Road West, Vail, Colorado 81657 1 / 1 COMcheck Software Version 4.0.6.1 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Construction Site: 660 W. Lionshead Pl Vail, CO Owner/Agent: Lionshead Lodge 660 W. Lionshead Pl Vail, CO Designer/Contractor: Andrew Wilder Wilder Engineering LLC 1170 Blue Sage Drive Steamboat Springs, CO 80487 970-819-7848 Project Information Energy Code: Lion Square Lodge Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Gore Creek (Common Space Types:Conference/Meeting/Multipurpose) 2492 1.23 3065 1.00 130(b)Allowance: Decorative Appearance / Fix. ID: FB 800(a) 1.00 800(b)Allowance: Decorative Appearance / Fix. ID: FC 800(a) 3995Total Allowed Watts = (a)Area claimed must not exceed the illuminated area permitted for this allowance type. (b)Allowance is (B x C) or the actual wattage of the fixtures given in Proposed Power section, whichever is less. Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Gore Creek ( Common Space Types:Conference/Meeting/Multipurpose 2492 sq.ft.) LED 1: FB: Sconce: LED PAR 13W: 1 10 13 130 LED 2: FC: Chandelier: LED Other Fixture Unit 46W: 1 6 300 1800 LED 3: FE: Linear: LED Linear 33W: 1 34 33 1122 LED 4: FF: Wallwash: Other: 1 5 50 250 3302Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.6.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Andrew Wilder - PE Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Gore Room.cck 02/10/18Report date: 51 of Page 2-12-18 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.6.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies? Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Gore Room.cck 02/10/18Report date: 52 of Page Section # & Req.ID Rough-In Electrical Inspection Complies? Comments/Assumptions C405.2.1 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable C405.2.1 [EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable C405.2.1, C405.2.2. 3 [EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable C405.2.2. 1 [EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable C405.2.3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable C405.2.3, C405.2.3. 1, C405.2.3. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable C405.2.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable C405.2.4 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Gore Room.cck 02/10/18Report date: 53 of Page Section # & Req.ID Final Inspection Complies? Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Gore Room.cck 02/10/18Report date: 54 of Page Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Gore Room.cck 02/10/18Report date: 55 of Page COMcheck Software Version 4.0.6.1 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Construction Site: 660 W. Lionshead Pl Vail, CO Owner/Agent: Lionshead Lodge 660 W. Lionshead Pl Vail, CO Designer/Contractor: Andrew Wilder Wilder Engineering LLC 1170 Blue Sage Drive Steamboat Springs, CO 80487 970-819-7848 Project Information Energy Code: Lion Square Lodge Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Wildwood Room (Common Space Types:Conference/Meeting/Multipurpose) 3019 1.23 3713 1.00 2400 (b)Allowance: Decorative Appearance / Fix. ID: FC 2400 (a) 1.00 52 (b)Allowance: Decorative Appearance / Fix. ID: FB 2400 (a) 6165Total Allowed Watts = (a) Area claimed must not exceed the illuminated area permitted for this allowance type. (b) Allowance is (B x C) or the actual wattage of the fixtures given in Proposed Power section, whichever is less. Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Wildwood Room ( Common Space Types:Conference/Meeting/Multipurpose 3019 sq.ft.) LED 1: FA: Downlight: LED PAR 20W: 1 82 21 1722 LED 2: FC: Chandelier: Other: 1 12 300 3600 LED 5: FB: Sconce: LED PAR 13W: 1 4 13 52 LED 6: FD: Wallwas: LED PAR 20W: 1 5 21 105 5479Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.6.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Andrew Wilder - PE Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Wildwood Room.cck 02/10/18Report date: 51 of Page 2-12-18 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.6.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies? Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Wildwood Room.cck 02/10/18Report date: 52 of Page Section # & Req.ID Rough-In Electrical Inspection Complies? Comments/Assumptions C405.2.1 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable C405.2.1 [EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable C405.2.1, C405.2.2. 3 [EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable C405.2.2. 1 [EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable C405.2.3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable C405.2.3, C405.2.3. 1, C405.2.3. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable C405.2.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable C405.2.4 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Wildwood Room.cck 02/10/18Report date: 53 of Page Section # & Req.ID Final Inspection Complies? Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Wildwood Room.cck 02/10/18Report date: 54 of Page Project Title: Data filename: Lion Square Lodge C:\_Wilder Engineering\_Projects\Kohler Design\201772 - Lion Square Lodge\Calculations\Wildwood Room.cck 02/10/18Report date: 55 of Page