Loading...
HomeMy WebLinkAboutB18-0218_A101_1543449573.pdf ..„:7040104.44, 0:15 9:11S. klib 0 Q0]' ELECTRICAL LOAD CALCULATIONS: LIGHTING SYMBOLS GENERAL ELECTRICAL NOTES: 11/28/18 EXISTING HOME ELECTRICAL SERVICE: 150 AMPS 0A RECESSED CAN LIGHT: 1. POWER AND LIGHTING DISTRIBUTION TO FIXED DOWN LIGHT FOLLOW REQUIREMENTS PER 2015 IRC TOTAL LIGHTING LOAD(3500SF @ 3VA/FT): 10,500 VA TWO 20A APPLIANCE OUTLET CIRCUITS: 3,000 VA 2. POWER AND LIGHTING TO CONFORM TO LAUNDRY CIRCUIT: 1,500 VA © RECESSED LENSED SHOWER LIGHT THE 2014 NATIONAL ELECTRIC CODE. RANGE: 10,000 VA WATER HEATER: GAS fA SURFACE MOUNTED LIGHT FIXTURE 2. PER 2015 IECC, 75% OF ALL NEW LIGHTING DISHWASHER: 1,500 VA TO BE HIGH EFFICACY CLOTHES WASHER: 1,500 VA CLOTHES DRYER: 5,000 VA S SWITCH 3. ALL EXISTING OUTLETS&SWITCHES TO CURRENT MICROWAVE: 1,500 VA REMAIN,MODIFICATIONS AS SHOWN ON FURNACE (2): 3,000 VA PLANS,VFY NEW SWITCH LOCATIONS ARCHITECTS HOT TUB: 1,500 VA /0, BATHROOM EXHAUST FAN DISPOSAL: 1,500 VA 4. ELECTRICAL WALK-THRU IS REQUIRED AND ASSOCIATES HEAT TAPE: 2,000 VA WITH ARCHITECT AT ROUGH-IN TOTAL: 42,500 VA 0 COMBINATION SMOKE AND PO BOX 5293 CARBON MONOXIDE DETECTOR 5. TYPICAL COLOR OF OUTLETS, SWITCHES, VAIL,COLORADO 81657 APPLICATION OF DEMAND FACTOR(220.82 b) AND COVERS(LUTRON ARCHITECTURAL 970 331.6345 MATTE): ALMOND (AL)DRYWALL wnrw.cur entarchitects.com FIRST 10 KVA OF GENERAL LOAD @ 100%: 10,000 VA GROUND FAULT DUPLEX OUTLET, LOCATIONS; BROWN(BR)STONE & REMAINDER OF GENERAL LOAD @ 40%: 13,000 VA +42" U.O.N. NATURAL WOOD LOCATIONS, VERIFY. TOTAL: 23,000 VA 6. TYPICAL SWITCH HEIGHTS: 48"AFF TO c 23,000 VA/240 VOLTS= 96 AMPS THE TOP OF SWITCH BOX FOR STANDARD �Or O O SWITCHES, +42"AFF TTT FOR BESIDE �� W. MICHAEL I7,0EXISTING SERVICE= 96 AMPS SWITCHES CUR ENT 0 7. LED LIGHT COLOR TEMPERATURES: CLOSETS AND BATHS=4000K (WHITE) i i ALL OTHER LOCS = 3000K(WARM WHITE) 402525 / 13'- ' 13'-62" / 8'-6 �/f/s `\\� ...w. 1 Fp ARG ` SAF- ' " .ter # _ _ — a' Il ` 4I I _ / r" . I , '.' / / =, O'' 40# ,A0 / / fi I ,., / 17.44/0i / , I 321 ` / ,�' 3'-O" 4,_0' 3'-0" Z / 2'-6" /1'-6"/1'-6"/ 3'-0" / +' ' NEW BATH FOR BEDROOM 2. INCLUDES / /1'-6"/-6" CRAWL/STORAGE +I f r DEMO OF EXISTING FLOOR&STAIR 1 FRAMING TO EXTEND EXISTING LANDING, A II Co, „ s VERIFY LOC. OF CLOSET ABOVE,ALIGN WEST WALL/51:/// I _ LIGHT AND VENTILATION Ilk ••45- / ,- di 1 VIIIA � _ I - w _ _: EXISTING STEP AND ELEC PANEL TO v v i�� PER IRC R303.3 REMAIN , ,o / I _ '*` �. J x A./ Q----�-- � ONE STEP AT ENTRY IF REQ'D. A. f CS I -- - - co p 1 co Z � 3 N z 6 • * 41 11A Wit . if / / ' - ' : T f Wil NO CHANGE TO EXISTING T SMOKE AND CO DETECTORS EGRESS COMPONENTS IN ANY 1 : 0 * 01 * .. ° a) a /../„.. .., .,,,,,.. ,,,, SLEEPING ROOM, EXCEPT PER IRC R314 AND R315 , rag BEDROOM 4 I 4. o-.. , POSSIBLE ADDITIONAL STORAGE H / 2 2'-4” / 6'-8z" 2'-4" /1'-7"/ LOCATION UNDER STAIRS FOR ' * VERIFY WORKING SMOKE AND BEDROOM 4? —� - �••�-�--• ---� �-� � 1 CO DETECTORS PER IRC R314 * - I AND R315 INSIDE EACH BEDROOM 1 BEDROOM REPLACE EXISTING NON EGRESS WINDOW , r Ira 2 °X° 4 (NEW) WITH NEW +/-34"x60"CASEMENT WINDOW, . "i ,+ I SLEEPING ROOM AND OUTSIDE N NEW HEADER NOT REQ'D, LOWER SILL TO 011 \ 111 ARE A, INSTALL �\ z 3z� r ±34 AFF _ EACH SLEEPING NEW AS REQ'D. \D+c9° — ' ; \\ - TWO STEPS AT ENTRY TO BEDRM TO REMAIN i I 3._4„ y +2'_ " (STEPS ARE+/-6"EA. LAUNDRY-12" BELOW BEDRC " F NEW FIXT. IN EXTG LOCS., / r )/ / DOOR DOES NOT SWING OVER STEP) w �� iip I" LIGHTING AND VENTILATION UP �,N iv NEW CLOSET .... - WIN ll i ._ ._. • ,� _� r. - � '�. . M" .. I �. � - - PER IRC R303.3 z 7 I A s4 • + ,•14 'air 1 M _ — — `� PO g to ,!�A i 1 I ' _, T I _ _ S .���, tik \ Z # �.. _ � �' 36"FRIG w 1� , - !4 i I10 \ — moi► .s iiiiratil :.-r Ci 71,1 i___ i iif: NEW 30",<400CFM 01 .,. , ...... 0 121 'Zi J f1 .c�. y I RANGE HOOD, GVHD - / . r ,-, - i . i . �._ 1, 7 NEW POWER AND LIGHTINGU) 1 I i • �� ^'!F� DEMO UPPER LEVEL ENTRY PER IRC CHAP 39 \� w 4;14;I I r - t �� :.�- WALL,DOOR,AND CLOSET i I I" i Y A ,�. � = pi wdimaila .-� _ _ _ M1 NEW 36"H RAILING AT STAIR, NOT TO ` = aim ' 111/0111111C /PPji, ALLOW THE PASSAGE OFA 4" SPHERE— - 1 E i F 11 IN , . a -_l e: DN NO STRUCTURAL MODS., WRAP — - � a � - EXTG COL. TO REMAIN _- t �` 71 ' - . - -r DEMO EXTG. /' - . .,�.�� -.�.. : _ � ;'. o 17..0,---- PARTITIONS, NO z • g - ill t i , ' + .. - I 4 ' NEW 36"H CONT. HANDRAIL o,(,,• iii•\•O� STRUCT.CHANGES U Q • .__ _._- # .......�. w� i PER IRC R311.5.6 „. II • J Ct O E E - < Ct --i I - - NEW SEAL . GAS FIREPLACE = W 0 , AM NG,CLE RNACE , F ' I A S (n ► ANDAPPLIANCEVENTIN 'ER MANF'R U J 0i I i� k \ lir C r _ (I) C ILEIMMOIM - _ lip ah i * t . — — A:. \,---wgm-Mf--„,/fik„_, , . - ' irk EAT ROO i 0 !4) ' . _.../._".._.„.. PROJECT : 17-SCH p DRAWN BY : .00 11/41/4\ti i % -I DATE : 11.13.2018 \\:4. , 'de. _„ , oji. .0 orf Q 4 REVISIONS : ,,„-pe- ill\'%Ni , )14 #110 4 %.44441.41'S . frit N4,..;' i;r1 i 't MilF4 01. .4.' 41;)I .- ‘% ,,, ., .. . .. ,e' , vev i ____ _ 1 +� Ye'Gr'1•a•� Ir •ei C 0 1 i . t. IV I f .4 FLOOR PLANS I - m_yeke+MitME . OM IMMII.11111.01.110111 A 1 0 1 . I EXISTING MAIN LEVEL PLAN 4 PROPOSED MAIN LEVEL PLAN 1/4”= 1'-0" 1/4"=1'-0" ��