Loading...
HomeMy WebLinkAboutDRB18-0575_Approved Documents_1543504554.pdf Design ReviewBoard(DRB) Department of Community Development 75 South Frontage Road West TOWN OF VAIL ACTION FORM Vail,CO 81657 Tel: 970-479-2139 www.vailgov.com Project Name: SchachtResidenceAddition Application Number: DRB18-0575 2018 Application Type: Change to Approved Date Applied: 11/20/2018 Project Description: New fireplace flue vent termination CONTACTS Contact Ty pe: Applicant Full Name: Current Architects (Michael Current) Address: PO Box 5293 x Vail, CO 81657 Phone: 9703316345 Contact Type: Property Owner Full Name: ROBERT & SELINASCHACHTFAMILY TRUST Address: Phone: None Project Address: 1800 SIERRATRL(210312312020) (210312312020) Job Site Location: No Legal Description: Subdivision: VAIL VILLAGE WEST FILING 1 Lot: 25 Block: Data Parcel Number: 210312312020 BOARDS/STAFF ACTION Motion By: Action: Staff Approved Second By: Vote: Date: 11/27/2018 Conditions: - All exposed metal flashing,trim,flues,vents, and rooftop mechanical equipment shall be anodized, painted (adjacentfacade/roofmaterial color or flat black), or capable of weathering so as to be non-reflective pursuant to Section 14-10-5C, Building Materials and Design, Vail Tow nCode, prorto requesting final inspections. - Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. - Design Review Board approval does not constitute a permit for building. Please consultw ithTow not Vail building personnel priorto construction activities. - Design Review Board approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Tow nCode, Chapter12-3-3 Appeals. - No changes to these plans maybe made without the written consent of Tow not Vail staffand/orthe appropriate review committee(s). - Applicant shall paint the fireplace flue termination black, or to match the color of the chimney siding. Planner: Chris Neubecker PLANNING FEE RECEIPT TOWN OF VAIL Case # DRB18-0575 Date Printed: 11/29/2018 TOWN OF VAIL - FEES RECEIPT Planning Summary Type: Design Review Board(DRB) Submittal Date: 11/20/2018 Subcases: Change to Approved Bond Expire D ate: Description of Work: New fireplaceflue vent termination Property Information Address: 1800 SIERRA TRL(210312312020) Tax ID: 210312312020 Owner: ROBERT&SELINA SCHACHT FAMILY TRUST Contacts Contact Type: Applic ant Company Name: Current Architects Full Name: Michael Current Address: PO Box 5293 x Vail, CO 81657 Email: michael@currentarchitects.com Contact Type: Property Owner Full Name: ROBERT&SELINA SCHACHT FAMILY TRUST Address: Planning Fees Fee Information Account Amount Changes to Approved Fee 001-0000.31122.00 $20.00 Payment Information D ate Paid Payment Type Amount Changes to Approved Fee 11/20/2018 Credit Card $20.00 Paid By:Web payment-Notes:Transaction ID:41061619552,auth c ode:08389G FEE TOTAL $20.00 AMOUNT PAID $20.00 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 11/29/2018 -8:09:42 AM-Generated by:cgodfrey 1/1 • , ' ,Ir J r / - a / i i `ti V DirectVentPro .-��1_ �, Unitized, co-axial venting system f ar driii. I direct vent gas or 11 '� propanestoves,and fireplaces4 I. , p (vs ® Venting Systemf or Category I I, I I I,and IV gas appliances. Listedto UL-1738 and ULC 5636. Specifications Applications DirectVentPro DirectVent Pro is a unitized,coaxial DirectVent Pro featurestightinner connections for superb (concentric)venting system designed performance,with no gaskets or sealants required(unless specified for use with direct vent gas or propane by th eappliance manufacturer). All black pipe length s,pipe stoves,h eaters,and fireplaces. extensions,and elbows feature laser-welded outer wall seams for a Materials and Construction sleek finish.Low-profile locks and no hems .020"aluminum inner wall. or beads allow for a beautiful product that looks elegant in .018"galvanized steel outer wall. any interior. Painted outer walls made of laser- welded .018"galvalume steel.Caps also DuraVent's direct vent is specified by nearly every major stove and available in stainless steel and copper. fireplace manufacturer in theU.S.and Canada,with thelargest Outer pipe brings combustion air to th eappliance.Inner pipe exh austsflue choiceof termination caps for direct vent available. gases to th eoutside. Gaskets or sealants not required(unless specified by th e appliance manufacturer). Clearances Specified by th eappliance manufacturer. Diameters 4"x65/8"and 5"x8". Listings DirectVent Pro,in combination with th e gas appliance,has been tested and listed as a decorative gas appliance system or as a direct vent heater system by a major testing agency,such as UL,CSA, or Warnock Hersey.Checkwithyour appliance manufacturer for approval. o • - -1ii } r Oki • - HOT • P 210 DuraVent I www.duravent.com DirectVent I DirectVenlPro Typical Installations Installation Key 111 VerticalTerminationCap 9 90°Elbow O 1 © StormCollar 10 HorizontalTerminationCap u15 , © Flashing IIISnorkelTerminationCap 2 r k.'-.',1,g �% 10 3 - 5 k. , 4 CathedralCeilingSupportBox ® ColinearKit © Pipe ® 3"or4"Flex 8k VI 6 45°Elbow Co AxialtoCo LinearConnector 5 5 IIClassAChimney ConversionKit ® Masonry Chimney ConversionKit 15 a • 4"Flex 16 Elbow Strap 5 9 'ill. II :\viii \ 5 I \\\ � •Ref erto our Typical Venting Installation drawings to select the appropriatecomponent e ..444 parts foryourinstallation. 1 v•p•- 0 tlI4 ' W Cathedral Ceiling Masonry Chimney Stove Installation Conversion 1 1 :t„>; 90°Elbow tail o WallThimbleCoveror s 2 410. l'IT'''''' Nit WallThimble pl. SconceTerminationCap iid �/ 6 5 tea ��- r its r 16 $ __-- StraightPipe Length III 11 • �I 6 A 5 Fireplace Metal Chimney VerticalTermination Conversion 1 'WO - 1 \ %12 \Sr- RigIg$0 .e<1 g . _0, 13 \g�ey i=,s$ 1 \7t 5 \ 11 .s R",�i 8'8� Stove with Snorkel VII 0:. \� QIi 13 HorizontalTermination o gal V 5 \moi 10 1 101 \\ \\\\\ai/� `, 5 f ��r% 14 1111 Co-Linear Insert Stove Hor izo nta lTer mi nation 800-835-4429 I DuraVent 211 Specifications Applications Listings continued... Concentric Venting System(CVS) Listed in combination with gas appliances,has been tested and (direct v entor two-pipe system)for use listed as a decorativ egas appliance system or as a direct vent with condensing natural gas or propane heater system. Check with your appliance manufacture for Categories II, Ill and IV appliances or approval. Canada's Type BH Gas Vent Systems, (hav inga maximum rated operating Diameter temperatureof 500°F). 3"inner and 5"outer. For use with Stov esand inserts of Type L gas,pellet,oil,corn and biofuel (Rated to a continuous use flue temperature up to 570°F). CVS can be used on a wide range of CVS Concentric Venting System appliances,including:gas boilers,warm An economical ventingsolution for condensing and air furnaces,water heaters,unit heaters, non-condensing appliances,the Concentric Venting System(CVS) tank less water heaters,pellet stov es, featuresa UL1738 approv edsuper-ferritic stainless steel inner direct v entgas or propane stoves, heaters and fireplaces. wall.The proprietarytwist-lock connection eliminates use of clamps or mechanical fastenersand saves installation time.Only Materials and Construction one penetration is needed through the roof or the wall for both Unitized concentric construction. exhaust and combustion air.Multiple pipe lengths and telescoping Inner:Laser-welded super-ferritic pipes eliminate field cutting of pipe.CVS is the only concentric stainless steel.012" ventsystem to incorporateo-rings on the inner wall and outer Outer:Laser welded,paintable, casing to preventexhaust or combustion air leakage. galvalume.018" Silicone 0-ring seals on inner liner and outer wall.Precisiontwist-lock The built-in condensate management system preventsstanding connection on outer wall. condensation.The Concentric Venting System is a fully sealed,gas tight system to deliver superior performancewith the heating unit. Clearances CVS is listed to 0"clearance as a double wall ventsystem forCategory II, Ill,and IV appliances,forflue temperatureof up to 400°F for horizontal enclosures, and up to 480°F fory erticalenclosures. CVS must maintain 1"clearance to combustibles when used with pellet fuel. r When CVS is used as a concentric/ direct v entsystem on gas,the clearance . ., 1 . pfw. - to combustibles are specified by the i appliance manufacturer. Listings Listed to UL 1738(DGSH.MH25700)and 11111111Pa ULC S636(DGSH7.MH25700).Pressure rated to 10"W.C. g Listed to UL 641 (DFTX.MH8381),ULC S609(DFTX7.MH8381),and ULC/ORD441 (DFVAC.MH21150). C ® US 212 Advantages of Concentric Typical Installations A concentric(or direct-v ent,or two-pipe) system maintains indoor air quality by reducing drafts with one penetration, and allows for better humidity level HorizontalTermination control inside a dwelling.Concentric i \ -1 OuterTrim Ring ventingbrings to the heating appliance i = Inner Trim Ring outdoor air as combustion air through 41� Wall Strap an air-tight,sealed system that is safe. d le VentLength Horizontal 43rfr Elbow Termination / V entLength 90°Elbow - Wall Thimble IncreaserTee Straight w/Clean-Out Length Pipe Horizontal GasInstallation Appliance r��^ Air Intake Adapter �,`�� Manifold 0QIII[ V erticalTermination I `�- 41. Storm Collar Horizontal Pellet Installation Flashing 11 V erticalCap Flashing �p�. Firestop Support ir e .140 rm \J VentLength ` CoStllar I//� JjJ , 45°Elbow/ FirestopSupport Straight Length Pipe -0% f'vf .���� Elbow Attic Insulation 1 I Shield i1 Wall Strap Ceiling Support Appliance Firestop Spacer Adapter Elbow e �:III Teew/Clean-Out V entLength +_ VerticalGas Installation O. VerticalPellet Installation DirectVentPro I DirectVent Planning Your Installation For vertical gas stove installations,measure the height fromthe stove outlet to the ceiling to 1 determine the length of black pipe required.Select a ceiling support/wallthimble coveror a cathedral ceiling support box. To determine the length of galvanized pipe required,measure the ceiling thick nessand the vertical rise in an attic or second story.Firestopsare required at each floor level beyond the 2 firstfloorceiling support/wallthimble coveror cathedral ceiling support box.If an offsetis required to avoid obstructions,use a pair of 45°elbows. For propersupport,use elbow straps with offsets.Use wall strapsforlong vertical runs.Attic Insulation Shield is required in attic. 3 Measure the roof pitch.Select the properflashing and storm collar.Determinethe minimum height above the roof. For horizontal installations,checkthe appliance manufacturer'sinstructionsforminimum rise and maximum horizontal run.A snork eltermination may be used if height restrictions 4 preventadequate rise above the appliance.Select the appropriateHorizontal Termination Cap(see appliance manufacturer installation instructions).Toprotect vinyl siding,select vinyl siding standoff.Check appliance manufacturer'sinstructionsforwall thimble and firestop requirements. Design Recommendation The following design recommendations are general guideline to assist in the design and selection of ventingcomponentsfor your installation.Always follow DuraVent Installation instructions enclosed with the cap or support box before installing your chimney system.Installation instructions can be viewed online at www.duravent.com,under Catalogs and Instructions. Important:Check the manufacturer's rating plate and instruction manual to confirm that the DuraVent direct v entsystem is ap- prov edfor use on the brand name appliance you haveselected. •The inner and outer pipe diameters should match the outlet size of the appliance. •Check the appliance manufacturer's installation instructions to confirm which types of ventconfigurations are permitted(i.e. horizontal,v ertical,chimney reline,etc.).Also,check for any venting restrictions such as maximum horizontal run,minimum and maximum vertical rise,maximum offset,etc. •Be fire safe!Maintain at least the minimum clearances(air-space) between the v entpipe and nearby combustibles,as specified in the appliance manufacturer's installation instructions.Use proper support and bracing.Follow local building codes and haveyour venting system inspected. 214 DuraVent I www.duravent.com DirectVent I DirectVentPro VentTermination Chart Minimum Height Roof Pitch Feet Meters Flatto7/12 1 0.30 Over7/12to8/12 1.5 0.46 as H / , Over8l12to9112 2 0.61 Over9l12to10112 2.5 0.76 Over 10/12 to 11/12 3.25 0.99 x Over 11/12 to 12/12 4 1.22 12" Over 12/12 to 14/12 5 1.52 HorizontalTermination Kit A Kit includes:9O°black Elbow,Ceiling Support/WallThimble Cover,24"black Pipe,8'/2"black Pipe Extension.Terminationcap not included. For 4"x 6 5/8"direct vent. Choose termination cap to complete installation. ORDER# STOCK# Pak 4"x 6 5/8" 46DVA-KHA 810001267 f HorizontalTermination Kit C Kit includes:90°black Elbow,Wall Thimble,Ceiling Support/ Wall Thimble Cover,24"black Pipe,8%z"black Pipe Extension. -xr;- Termination cap not included. For 4"x 6 5/8"direct vent. Choose termination cap to complete installation. ORDER# STOCK# 4"x 6 5/8" 46DVA-KHC 810001268 • 800-835-4429 I DuraVent 215 DirectVentPro I DirectVent Masonry Chimney Kit46DVA-KMC includes:Cap Adapter,18"x 18" Flashing,Round Ceiling Support/Wall Thimble Cover,Retro Connector. For 4"x 6 Conversion Kit 5/8"direct vent.TerminationCap and 4"flex are sold separately. 1� Kit46DVA-KCTincludes:Cap Adapter and a 18"x 18" Flashing. P } �� 8 Use with 4"x 6 5/8"direct ventgas stoves. Use existing masonry chimney.Route the exhaust gases and intake air through the side 13" of the masonry chimney. 2'/a"�• 81/4' SIZE ORDER# STOCK# ,- 4"x 6 5/s" 46DVA-KMC 810001274 Y gm-40 �� 4"x 6 5/s" 46DVA-KCT 810001275 18" 18" 65/ate IX ,e^r-...., `ro 6'/s" ....„, w• 85/8' I 33/s �4 t 63/t6t..tet 85/s" Chimney Conversion Kit Kits 46DVA-KCA,46DVA-KCB,and 46DVA-KCC include:Cap Adapter and a Retro Connector.DirectVent Pro 4"x 6 5/8" AA.- Termination Cap and 4"flex are sold separately. in .. Use with 4"x 6 5/8"direct ventgas stoves. Use existing through- s ',11._.:1___H-:#1 the-ceiling,wood-stovemetal chimney.Route the exhaust gases --m-- and intake air through the existing wood-stovemetal chimney. ...ve ORDER# STOCK# A B C 85/8" 4"x 6 5/s" 46DVA-KCA 810001276 6 5/s" 8 5/s" 6'/8" m.. ) 4"x 6 5/s" 46DVA-KCB 810001279 6 5/e" 10/2" 5'W'33/s4"x 6 5/8" 46DVA-KCC 810001280 6 5/s" 13" 5'/a" 65/8' 46DVA-KCAFITS: 46DVA-KCBFITS: 46DVA-KCCFITS: SDV5"-6"DURATECH SDV6"DURAPLUS&7"-8"DURATECH SDV7"-8"DURAPLUS 6"SECURITYCHIMNEY 8"SECURITYCHIMNEY 7"&8"DURAPLUS 6"METALBESTOS 7"&8"METALBESTOS 8"AMERICAN METALS 6"JACKES-EVANS 7"&8"JACKES-EVANS 8"AIR-JET 6"HART&COOLEY 7"&8"HART&COOLEY 8"METAL-FAB 6"PROJET 7"&8"PROJET 6"&7"AMERICAN METALS 6"&7"METAL-FAB 6"AIR-JET 216 DuraVent I www.duravent.com DirectVent I DirectVentPro Pipe Length Designed for appliances tested and listed for direct vent.Features a fully unitized twist-lockconstruction in both 4"x 6 5/8"and 5"x 8"v entsizes. Use of sealant is optional,unless specified by the appliance manufacturerTocalculate install length,subtract 1 1/2" ^� for each joint. No beads or hems.Black pipe lengthsfeature , exteriorlaser-weldedseams. 11 SIZE A GALVANIZED BLACK A ORDER# STOCK# ORDER# STOCK# 4"x 6 5/8° 6" 46DVA-06 810001281 46DVA-06B 810001282 4"x 6 5/8" 9" 46DVA-09 810001283 46DVA-09B 810001284 4"x 6 5/8" 12" 46DVA-12 810001285 46DVA-12B 810001286 4"x 6 5/8" 18" 46DVA-18 810001289 46DVA-18B 810001290 4"x 6 5/8" 24" 46DVA-24 810001291 46DVA-24B 810001292 4"x 6 5/8" 36" 46DVA-36 810001293 46DVA-36B 810001294 4"x 6 5/8" 48" 46DVA-48 810001295 46DVA-48B 810001296 4"x 6 5/8" 60" 46DVA-60 810001297 46DVA-60B 810001298 5"x 8" 6" 58DVA-06 810001369 58DVA-06B 810001370 5"x 8" 9" 58DVA-09 810001371 58DVA-09B 810001372 5"x 8" 12" 58DVA-12 810001373 58DVA-12B 810001374 5"x 8" 18" 58DVA-18 810001375 58DVA-18B 810001376 5"x 8" 24" 58DVA-24 810001377 58DVA-24B 810001378 5"x 8" 36" 58DVA-36 810001379 58DVA-36B 810001380 5"x 8" 48" 58DVA-48 810001381 58DVA-48B 810001382 5"x 8" 60" 58DVA-60 810001383 58DVA-60B 810001384 Pipe Extension Use to add length to a straight length of DirectVent Pro.8' "pipe adds 3"-7"of length, 16"pipe adds 3"-14'h"of length,when used with rigid sections of pipe.Directv entlengthsfeature a fully '�' _\ unitized,twist-lockconstruction.Use of sealant is optional,unless specified by the appliance manufacturerAvailable in black or 111 At galv alumeexterior(both feature laser-weldedouter wall seams). Does not fit DirectVentGS pipe. GALVANIZED BLACK SIZE A EXTENSION ORDER# STOCK# ORDER# STOCK# 4"x 6 5/8" 46DVA-08A 810001299 46DVA-08AB 810001300 81/2" 3"-7" 4"x 6 5/8" 46DVA-16A 810001287 46DVA-16AB 810001288 16" 3"-14 Yz" 5"x 8" 58DVA-08A 810001385 58DVA-08AB 810001386 81/2" 3"-7" 5"x 8" 58DVA-16A 810001387 58DVA-16AB 810001388 16" 3"-141/2" 800-835-4429 I DuraVent 217 DirectVentPro I DirectVent Adjustable Pipe Use of sealant is optional,unless specified by the appliance manufacturerAvailable in black orgalvalumeexterior(both I`F� �_�� feature laser-weldedouterwall seams). GALVANIZED BLACK I ORDER# STOCK# ORDER# STOCK# A INSTALLED 4"x 6 5/8" 46DVA-171A 810001301 46DVA-17TAB 810001302 11"-17" 9'/z"-15'Y2" A 4"x 6 5/8" 46DVA-24TA 810001305 46DVA-24TAB 810001306 17"-24" 15'Y2"-22 Yz" 5"x 8" 58DVA-171A 810001389 58DVA-17TAB 810006048 11"-17" 91/2"-15 Y2" 5"x 8" 58DVA-241A 810001390 -- -- 17"-24" 15 Y2"-22 Y2" 1 30° Elbow Use to offsetobstructionsas needed.Fully unitized,twist-lock construction.Elbowsswiv el,allowingthe lockto remainfully engaged while aligning to the desireddirection.The angle will B)4 remainfixed at 30°. 7.1I `' SIZE GALVANIZED A B A ` ORDER# STOCK# IMME 4"x 6 5/8" 46DVA-E30 810001307 5 3/4" 4 2/8" 5"x8" 58DVA-E30 810001391 6Y8" 5'/2" 45° Elbow Use to offsetobstructionsas needed.Fully unitized,twist-lock construction.Elbowsswiv el,allowingthe lockto remainfully 1 engaged while aligning to the desireddirection.Theangle will /riiii �) remainfixed at 45°. 1 ;7 1.* V .dOOLi GALVANIZED BLACK A B ORDER# STOCK# ORDER# STOCK# 4"x 6 5/8" 46DVA-E45 810001308 46DVA-E45B 810001309 5 3/4" 5 Y8" 5"x 8" 58DVA-E45 810001393 58DVA-E45B 810001394 6 5/s" 6" 60° Elbow Use to offsetobstructionsas needed.Fully unitized,twist-lock construction.Elbowsswiv el,allowingthe lockto remainfully ,\ engaged while aligning to the desireddirection.Theangle will B remainfixed at 6O°. GALVANIZED A B A ORDER# STOCK# J_IM=Mil 4"x 6 5/8" 46DVA-E60 810001310 41/4" 43/8" 5"x 8" 58DVA-E60 810001392 4Y4" 43/2" 218 DuraVent I www.duravent.com DirectVent I DirectVentPro 90° Elbow Use to offsetobstructionsas needed.Fully unitized,twist-lock construction.Elbowsswiv el,allowingthe lockto remainf ullyen- gaged whilealigningtothedesireddirection.The angle will remain fixed at 90°. ) / I 10• GALVANIZED BLACK A B 111M1041 1ORDER# STOCK# ORDER# STOCK# B 4"x 65/8" 46DVA-E90 810001311 46DVA-E9OB 810001312 6'/z° 61/2" 5"x 8" 58DVA-E90 810001395 58DVA-E9OB 810001396 73/8" 73/8" Elbow Strap Use for supporting ventpipe between offsets. ORDER# STOCK# A 4"x65/e" 46DVA-ES 810001313 65/8" 441 1)1111111 kommor IT 5"x 8" 58DVA-ES 810001397 8" 17" 4 A,".. Ceiling Support/ Use as a decorative cov erfor horizontal(through-wall)installations Wall ThimbleCover or forflat ceiling installations.Fits overthe Wall Thimble faceplate. Comes with an insulation ring to reduce air infiltration wherethe pipe slips through the thimble.Painted black. IP ORDER# STOCK# A B C 4"x 6 5/8" 46DVA-DC 810001314 6'/8" 13" 13" C ri j 5"x 8" 58DVA DC 810001398 8'/a' 13" 13" 21/8" Cathedral Ceiling Support Box Use to pass through ceiling and support pipe.May be used on vaultedor flat ceilings.Painted black.Trim and clamp included. B B /\` ORDER# STOCK# A 4" B x 6 5/8" 46DVA-CS 810001315 6'/a' 10 5/8" t . 5"x 8" 58DVA-CS 810001399 81/4" 10 5/s" 14" ''. A 4- 800-835-4429 I DuraVent 219 DirectVentPro I DirectVent Wall Thimble Prov idesa complete wall-pass-through and firestop.Use with Square Horizontal Cap only.May be required in Canada. Referto the appliance manufacturer's installation instructions 4" for requirements. °Aio ~ 4" ., ORDER# STOCK# A B d triz 4"x 6 5/8" 46DVA WT 810001316 6'/a° 11" 12"rI 5"x 8" 58DVA WT 810001400 8'/a' 12 Y2" 12 Y2"9' C ' ♦ B Wall Thimble- Small Prov idesa complete wall-pass-through and firestop.Use with Round Horizontal Cap,Sconce Cap and H2 Horizontal Cap only. May be required in Canada. Referto the appliance manufacturer's I -!.°1 4" installation instructions for requirements. � 0 ti °ri4 I 4 ORDER# STOCK# A yr 4"x65/8" 46DVA WTS 810001317 6'/a° B11" C 11" ,. 5"x 8" 58DVA-WTS 810001401 81" 11" 11" B UniversalWall Thimble Prov idesa complete wall-pass-through and interiorfirestop. Features an adjustable sleeveforan exact fit.Eliminatesvisible • __,... trim on exterior or wall near cap.Sized to fit all DuraVent 4 R DirectVent Pro's termination caps.Workswell for smaller square Orand sconce termination caps. A ORDER# STOCK# A B 0 ./ 4"x65/8" 46DVA-WTU 810001318 11" 6;/4" 5"x 8" 58DVA-WTU 810001402 11" 81/8" I. A� 220 DuraVent I www.duravent.com DirectVent I DirectVenlPro Wall Firestop For horizontal(through-wall) installations.Referto the appliance manufacturer's installation instructionsfor requirements. q oI ORDER# STOCK# A B C II �' Br .! _ 4"x65/8" 46DVA-WFS 810001319 63/4" 12" 10" B Ic S 5"x 8" 58DVA-WFS 810001403 81/4" 12" 10" B Wall Firestop 2 For horizontal(through-wall) installations.Referto the appliance manufacturer's installation instructionsfor requirements. 11"� ORDER# STOCK# A i 4"x 6 5/s" 46DVA-WFS2 810013110 63/4" 0 11 9" 11" OA 5"x 8" 58DVA-WFS2 810013111 81/4' 1 Vinyl Siding Standoff Use as a heat shield on structureswith v inylsiding,or other temperature sensitivematerials,to help preventwarping and or melting of the material.Use only on horizontal terminations and a� toil B 1�a' on any irregular surfaced siding (ie:ship lap siding,shake shingle V C siding)so cap is not imbedded in the siding. Sized for Square t0 I Horizontal Cap. �� ORDER# STOCK# A B C 4"x 6 5/s" 46DVA-VSS 810001320 63/4" 171/2" 13 1/2"5"x 8" 58DVA-VSS 810001404 8 Ya' 19'/8" 153/4" 800-835-4429 I DuraVent 221 DirectVentPro I DirectVent Vinyl Siding Standoff Kit Use as a heat shield on structureswith vinylsiding,or other temperature sensitivematerials,to help preventwarping and i� or melting of the material.Use only on horizontal terminations a A and on any irregular surfaced siding (ie:ship lag siding,shake l i shingle siding)so cap is not imbedded in the siding. Kit includes 4-pieces;sized for Square Horizontal Cap only.Stainless steel(SS) and Copper(C)available. ORDER# STOCK# A B C 4"x 65/8" 46DVA-VSK 810001321 15'/4" 13 Y4" 3" 4"x 6 5/8" 46DVA-VSK-SS 810001322 15'/4" 13 Y4" 3" 4"x 6 5/8" 46DVA-VSK-C 810001326 15 Y4" 13 Y4" 3" 5"x 8" 58DVA-VSK 810001405 17'W' 15'W' 3" 5"x 8" 58DVA-VSK-SS 810001407 17 W 15'W' 3" 5"x 8" 58DVA-VSK-C 810001406 17'W' 15'W' 3" Vinyl Siding Standoff Kit- Small Use as a heat shield on structureswith v inylsiding,or other temperature sensitivematerials,to help preventwarping and or 1 melting of the material.Use only on horizontal terminations and A on any irregular surfaced siding (ie:ship lag siding,shake shingle .cill:11111 -: i siding)so cap is not imbedded in the siding. Kit includes 4-pieces; sized for Sconce Cap,Round Horizontal Cap and H2 Horizontal Cap only.Stainless steel(SS)and Copper(C)av ailable.Use for4"x 6 5/8"and 5"x 8"diameters. SIZE ORDER# STOCK# A B C 4"x 6 5/8" 46DVA-VSKS 810001323 12'/8" 10'/8" 3" 4"x 6 5/8" 46DVA-VSKS-SS 810001325 12'/8" 10'/8" 3" 4"x 6 5/8" 46DVA-VSKS-C 810001327 12'/8" 10'/8" 3" Vinyl Siding Standoff Box Use as a heat shield on structureswith v inylsiding,or other temperature sensitivematerials,to help preventwarping and or melting of the material.Use only on horizontal terminations and on any irregular surfaced siding (ie:ship lag siding,shake shingle Ell11"--1 siding)so cap is not imbedded in the siding. Sized for Sconce I " Cap,Round Horizontal Cap and H2 Horizontal Cap only.Factory assembled.Use for 4"x 6 5/8"and 5"x 8"diameters. 11" �1 SIZE ORDER# STOCK# 3 1/8" 4"x 6 5/8"&5"x 8" DVA-BVS 810012706 222 DuraVent I www.duravent.com DirectVent I DirectVentPro Counter Flashing Prevents water intrusion into stucco-sided homes.Allows the installerto apply siding material(ie:stucco,brick,etc)ov erthe ik flanges up to the sides of the flashing fora water-tightseal. A Kit includes 4-pieces;sized for Square Horizontal Cap only. \`\(4‘ ORDER# STOCK# A B 4"x 6 5/8" 46DVA-CFK 810001339 15 Y4" 13'Y4" 2 4"x 6 5/8" 46DVA-CFK-S 810001342 15 Y4" 13'Y4" 2" 5"x 8" 58DVA-CFK 810001417 17 W' 15'/8" 2" Counter Flashing- Small Prevents water intrusion into stucco-sided homes.Allows the installerto apply siding material(ie:stucco,brick,etc)ov erthe 1.,,,,,,, flanges up to the sides of the flashing fora water-tightseal. it°61...1.11111\ A Kit includes 4-pieces;sized for 4"x 6 5/8"Sconce Cap,Round ��`� Horizontal Cap and H2 Horizontal Cap only.Also availablein �� - stainless steel(S).Use for 4"x 65/8"and 5"x 8"diameters. SIZE ORDER# STOCK# A B C 4"x 6 5/8" 46DVA-CFKS 810001341 12 7/8" 10 7/8" 2" 4"x 6 5/8" 46DVA-CFKS-S 810001340 12 7/8" 10 7/8" 2" Ceiling Firestop Required for multi-story vertical installations at the second floor and any subsequent floors.4"x 6 5/8"style may vary. C C� ORDER# STOCK# A B 1:11,._ .\A . 4"x 6 5/8" 46DVA-FS 810001328 6 3/4" 11" 9" B �/ B 5"x 8" 58DVA-F5 810001408 8'/4" 12 Y1" 10'Y2" Attic Insulation Shield Required for installations that pass through an attic to prevent insulation and debris from accumulating nearthevent. Provides 1"clearance to combustibles. Includes base w/tube,extension (365/e8,08" tube and collar. =• =� ORDER# STOCK# A B C 0A III Adjusts 4"x65/8" 46DVA-IS 810001329 83/4" 815/x" 11" 11"-20" 5"x 8" 58DVA-IS 810001409 103/4" 1015/s" 13"MI i ink, _4)._ [..- 800-835-4429 I DuraVent 223 DirectVentPro I DirectVent Wall Strap Use to supportventpipe.Prov ides1"clearance.Recommend installing Wall Straps at 4-foot intervalson verticalruns. ORDER# STOCK# A faliC.-.1;)----III A 4"x 6 5/8" 46DVA-WS 810001330 6 5/s" Nat,. EZI 58DVA-WS 810001410 8" 111/11/ RestrictorD isk Use only in accordance with specific appliance manufacturer's installation instructions to restrict incoming combustion air. -,(--' A B ORDER# STOCK# A B 4"x 6 ye 46DVA-RD 810001331 51/4' 49/u" MN) 5"x 8" 58DVA-RD 810001411 7" 6" Use to support DirectVent pipe at roof ley el. Roof Support SIZE ORDER# STOCK# A B "..L.1.1171,4=mmL B 4"x 6 5/8" 46DVA-RS 810013975 6 5/s" 17'" w ' f 1" 5"x 8" 58DVA-RS 810013976 8" 19 Y8" —42" Adjustable Roof Flashing Use to weather proof the penetration of ventpipe through the roof.Storm Collar required.Select roof flashing based on pitch of _ A: roof.For pitches of 0/12-6/12.Made of gals alume. � ORDER# STOCK# A B tli 4"x 6 5/e" 46DVA-F6 810001332 6 3/4" 19'/n" 19 Ya" /-NgN,6 EMI 58DVA-F6 810001412 8Y2" 21'/z" 21'/2" 224 DuraVent I www.duravent.com DirectVent I DirectVentPro Steep Roof Flashing Use to weather proof the penetration of ventpipe through the roof.Storm Collar required. For roof pitches of 7/12- 12/12.Made 1 A 'r ofgalvalume. ORDER# STOCK# A B C 0:4,44. B 4"x 6 5/8" 46DVA-F12 810001333 6 34" 21 Y2" 191/4" \`6 ` EZIE58D1412 810001413 8'/2" 231/2" 213/2" Flat Roof Flashing Use to weather proof the penetration of ventpipe through the roof.Storm Collar required.Use on flat roofs,chase enclosures,or A masonry chimney.Made of gals alume. itD-A�\ ORDER# STOCK# A 1 B C D o p R`0 4"x 6 5/8" 46DVA-FF 810001334 6 3/4" 21'Y2" 12" 4" �B D R ../B 5"x 8" 58DVA-FF 810001414 8 Y2" 23 Y2" 12" 4" Dead Soft Aluminum Flashings Use with metal ortile roofs.Availableinsizes 4"x65/s"and 5"x 8",in 0/12-6/12(shown)and 7/12-12/12 styles.Made of malleable dead soft aluminum. Referto roof flashings tables (prey iouspage)for dimensions. ,41\ A r STYLE ORDER# STOCK# A B C Agit: 4"x65/e" 0/12-6/12 46DVA-F6DS 810001335 63/4" 27'Y2" 24" C 4"x 6 5/8" 7/12-12/12 46DVA-F12DS 810001336 8Y4" 22" 25" B �/ 5"x 8" 0/12-6/12 58DVA-F6DS 810001415 8 Y2" 29 Y2" 24" 5"x 8" 7/12-12/12 58DVA-F12DS 810001416 81/2" 243/4' 27" Storm Collar Use to maintain a weather tight resistant seal between the pipe and the flashing. 4Q111),, ( _ m) ORDER# STOCK# A B 4"x 6 5/8" 46DVA-SC 810001343 6 5/8 10 5/8" 5"x 8" 58DVA-SC 810001419 8" 12" B- B A MO 01.0 800-835-4429 I DuraVent 225 DirectVentPro I DirectVent Round Horizontal Use forthrough-the-wall termination.Check installation instructions for restrictionson horizontal cap terminations,such Termination Cap as minimum distance from windows and doors.Available in Aaluminum only.Check with appliance manufacturerforapproval. I ORDER# STOCK# A B C D CO Cif A 4"x 65/8" 46DVA-HRCS 810001344 11" 5 3/a" 4" 6 5/8" B 5"x 8" 58DVA-HRCS 810001420 11" 5 3/4" 415/1" 8 Y8" 11111111uC I Sconce Termination Cap Use for horizontal through-the-wall termination.Check installation instructions for restrictionson horizontal cap terminations,such as minimum distance from windows and }5 �A1 doors.Available in aluminum,stainless steel(S),and copper(C). Check with appliance manufacturerfor approval.Patented. ,Q'44 ... � ORDER# STOCK# A B C D ? B l N� 4"x 6 5/8" 46DVA-HSC 810001345 11 Yw 11" 6 3/8" 12 3/8" D ),,,,,„(7°. C 4"x 6 5/8" 46DVA-HSC-S 810001346 11 1/16" 11" 6 3/8" 12 3/8" \ 4"x 6 5/8" 46DVA-HSC-C 810001347 11/15" 11" 63/8" 12 3/8" 5"x8" 58DVA-HSC 810001421 11 ye 11" 63/8" 123/8" 5"x 8" 58DVA-HSC-S 810001422 11/,e" 11" 63/8" 12 3/8" 5"x 8" 58DVA-HSC-C 810001423 11 Yb" 11" 6 3/8" 12 3/8" High-Wind Sconce Use for horizontal through-the-wall termination.Prov ides improvedperformance in high wind conditions.Check Termination Cap installation instructions for restrictionson horizontal cap terminations,such as minimum distance from windows and ,_A� doors.Available in aluminum,stainless steel(S),and copper(C).m Check with appliance anufacturerfor approval. ��/t Patented.Includes heat deflector that may be required by HO appliance manufacturer. \ f D C SIZE ORDER# STOCK# A B C D 4"x 6 5/8" 46DVA-HSCH 810001348 11 Ye 11" 63/8" 12 3/8" 4"x 6 5/8" 46DVA-HSCH-S 810001349 11 Y 11" 63/8" 12 3/8" 4"x 6 5/8" 46DVA-HSCH-C 810001350 11 Yb" 11" 63/8" 12 3/8" 5"x 8" 58DVA-HSCH 810001424 11 Yb" 11" 63/8" 12 3/8" 5"x 8" 58DVA-HSCH-S 810001425 11 Yb" 11" 63/8" 12 3/8" 5"x 8" 58DVA-HSCH-C 810001426 11 Yb" 11" 63/8" 12 3/8" 226 DuraVent I www.duravent.com DirectVent I DirectVentPro Square Horizontal Use for standard and high-wind through-the-wall termination. Check installation instructions for restrictionson horizontal cap Termination Cap terminations,such as minimum distance from windows and doors.Available in aluminum,stainless steel(S),and copper(C). A ORDER# STOCK# A B C D ri-- ,_ • . 4"x 6 5/8" 46DVA-HC 810001351 13'Y2" 6'/s" 121/2" 6 5/8" n I 4"x 6 5/8" 46DVA-HC-S 810001352 131/2" 6'/8" 12'/2" 6 5/8" A / n I Ir 4"x 6 5/e" 46DVA-HC-C 810001353 13'Y2" 6'/e" 121/2" 65/8" l C B 5"x 8" 58DVA-HC 810001427 16" 67/8" 12'/2" 8'/8" R 5"x 8" 58DVA-HC-S 810001428 16" 6'/8" 12'/2" 8'/8" 5"x 8" 58DVA-HC-C 810001429 16" 67/8" 12'/2" 8'/8" Square Horizontal H2 Use for standard and high-wind through-the-wall Adjustable termination.Provides improv edperformance in high wind Termination Cap Throttle conditions. Features an adjustable air intake and interchange- able shroud(shroud is included and required for all installations). ill fo Check installation instructions for restrictionson horizontal cap terminations,such as minimum distance from windows and doors.Av ailablewith aluminum shroud.Check with appliance manufacturer for approv aland air throttle setting. May be painted at installation to match the wall. Patent Pending. Termination Cap with AL Shroud 7„ 1 612^_ SIZE ORDER# STOCK# A 4"x 6 5/8" 46DVA-H2 810012624 6 3/a" T 5"x 8" 58DVA-H2 810012625 8'/a" OA 11 L Alternate/Replacement Shroud - SIZE ORDER# STOCK# Material 11" DVA-TR-AL 810013071 Aluminum 4"x65/8"&5"x 8" DVA-TR-SS 810013072 Stainless Steel Snorkel Termination Cap Use forhorizontalthrough-the-wall terminationwhenavertical rise is desired in the systemto meet appliancemanufacturer B recommended minimum heights.Do not enclosein the wall "g`o or install belowgrade. ORDER# STOCK# A B B C4"x 6 5/8" 46DVA-SNK14 810001355 10" 233/4: 14" 4"x 6 5/s" 46DVA-SNK36 810001356 10" 453/x" 36" �D 5"x8" 58DVA-SNK14 810001430 10" 233/4" 14" A1:1 I-..- 5"x 8" 58DVA-SNK36 810001431 10" 453/4" 36" 5 1/z" • 800-835-4429 I DuraVent 227 DirectVentPro I DirectVent Snorkel H2 Termination Cap Use forhorizontalthrough-the-wall terminationwhenavertical rise is desired in the systemto meet appliancemanufacturer recommended minimum heights.Do not enclosein the wall -1/41 or install belowgrade.Prov idelmproved performance in high wind II ,_ _ y conditions. Featuresan adjustableair intakeand interchangeable shroud(shroud is included and required forall installations). Check 1 with appliancemanufacturer forapprovahnd air throttlesetting. J— B O PatentPending. OA . 1— _____— SIZE ORDER# STOCK# A B C 4"x65/8" 46DVA-H2-SNK14 810012915 63/4' 14'Y2" 27" 4"x 6 5/8" 46DVA-H2-SNK36 810012916 6 3/4' 37" 49'/2" 5"x 8" 58DVA-H2-SNK14 810012917 81/8" 15" 28" MEI 58DVA-H2-SNK36 810012918 8'/8" 37 Y2" 50'Y2" HorizontalWindguard Use withthrough-the-wallterminationcapwherehighwinds are presentAlso use as a safetyheat shield to prey ent=hildrenor others 12„ fromcoming into contactwiththeventterminationcap. 23" �2. Fits both 4"x65/s"and 5"x8"terminations. ii iMilfgiP :• ''.w y~.. SIZE ORDER# STOCK# y'• 131/2" 4"x 6 5/s"&5"x 8" 46011A-W0 810001357 17 �i2„ High-Wind Termination Cap Use forverticalterminations only.Provides improved performance in high wind conditions.For verticalterminations O� only.Available in aluminum. Ill i= ORDER# STOCK# A B C D I��!' 4"x 6 5/s" 46DVA VCH 810001359 12 3/8" 65/8" 75/8" 101/2" JHIL 5"x 8" 58DVA-VCH 810001432 123/8" 8" 7 5/8" 10'/2" A %a■D 2K 228 DuraVent I www.duravent.com DirectVent I DirectVentPro VerticalWind Guard Use only with High WindTermination Cap when additionalwind protections needed.Fits both4"x 6 5/8"and 5"x 8"terminations. X13" lir* .;/ ______4t1 ORDER# STOCK# W 4"x 6 5/8" 46DVA-VWG 810001358 ijk. 9" '.."------ Low-Profile Termination Cap Use forverticalterminations only.Check the appliance manufacturer's instructions to determine which caps are D approv edfor use with their appliance.Available in aluminum and stainless steel(S). \ ORDER# STOCK# A B C D C 4"x 6 5/8" 46DVA-VC 810001360 8 Y4" 6 5/3" 3 Y/' 12 Y2" A til B 4"x 6 5/8" 46DVA-VC-S 810001361 8 Ya' 6 5/3" 3 Ya" 12 Y2" A" 5"x 8" 58DVA-VC 810001433 8 5/s" 8" 7 5/3" 12 Y2" 5"x 8" 58DVA-VC-S 810001434 8 5/s" 8" 7 5/8" 12 Y2" Extended Vertical Use in extremely cold climates.Similar to the Low Profile Termination Cap but taller in overallheight to separate the Termination Cap air intake v entsfrom the exhaust area.Referto the appliance ..VDmanufacturer's installation instructionsfor requirements. iiiiillaft Available in aluminum. t''� • �� ORDER# STOCK# A B C D 111 4"x 6 5/s" 46DVA-VCE 810001362 16 3/4" 6 5/3" 113/4" 12 Y2" - A C 5"x 8" 58DVA-VCE 810001435 16 3/4" 8" 11 Ys" 14 Y2" t _ A' B Aluminum Flex Length Use 3"flex with the co-linear system and 4"flex with Conversion Kits.See DuraFlexAL section for more information.Flexible.010" thick 2-ply aluminum. Pricing for Aluminum Flex Length are listed under DuraFlexAL. i LENGTH ORDER# STOCK# • ""' 3" 35' 3DFA-35 810002988 4" 35' 4DFA-35 810002998 800-835-4429 I DuraVent 229 DirectVentPro I DirectVent Flex Coupling Use to join flex liner sections together.Pricing for Aluminum Flex Length are listed under DuraFlexAL. 3" SIZE ORDER# STOCK# 3 °' 3" 3DFA-FC 810002992 4[:FA-FC 810003000 Co-Axial To Co-Linear Appliance Use Co-Linear Adapter for stov eswith 4"X 6 5/8"co-axial outlets. Connector Referto appliance manufacturer's installation instructions for approv al.Uses aluminum flex for both intake and exhaust. =,k. B SIZE CONNECTOR ORDER# STOCK# A B C D ©11 T/�% 4"x65/e" STANDARD 46DVA-GCL 810001363 10 Y2" 3" 7'Yz" 7'Ye" 3" 3" 114%. A ir — 4"x 6 5/s" STANDARD 46DVA-GCL34 810004565 10 Y2" 3" 7 Y2" 7 Ye" 4" 3" ri � - FTRAVIS 4"x 6 5/8" 46DVA-TCL 810001364 10 Y2" 3" 7 Y2" 6;/s" 3" 3" D—► INDUSTRIES 4"x65/s" VERMONT 46DVA-VCL 810001365 10 Y1" 3" 7Y:" 85/s" 3" 3" CASTINGS Chimney Liner Termination Kit Kit includes:TerminationConnector and Flashing.DirectVent Pro4"x 6 5/8"TerminationCaps,3"Flex,and Co-Linear Flex Connectors are sold separately. 10".-4:4 inio DirectVent Pro chimney liner termination kit must be tested l '.111--1(10)11 and listed for each appliance.Referto stovemanufacturer's B installation instructions. 0 ORDER# STOCK# OA OB �18'�/��18 4"x 6 5/8" 46DVA-GK 810001269 3" 3" 4"x 6 5/s" 46DVA-CT 810001368 4" 3" Appliance Adapter Attaches to appliance outlet allowing pipe to easily connect or disconnect.Vermont Castings adapter#2768. 165/s I 1 ITI - t ORDER# STOCK# 13„ 4"x 6 5/8" 46DVA-ADP 810001366 1 15„ 1 11--31/16" i 230 DuraVent I www.duravent.com DirectVent I DirectVenlPro Reducer Use to reduce ventdiameter.Check with appliance manufacturer for approv al. 411 . I—A^I SIZE REDUCE TO ORDER# STOCK# A B ,t I� 5"X 8" 4"x 65/8" 58DVA-1 810001436 6 5/d' 8" e e1 I-.— B—I 6"X 85/8" 5"X 8" 68DVS-X58 810006145 8" 85/8" Co-Linear Flex Connector Use as a flex connector with inserts with 3"co-linear intake and exhaust ports. ■ 39/6' t �� SIZE ORDER# STOCK# 13" 4"x 65/8" 46DVA-ADF 810001367 I 4' OR M- 3" Co-Linear Kit w/Flex Use when installing a direct ventco-linear insert into a masonry chimney. Kit includes:Choice of High-Wind TerminationCap or Prairie Ilia TerminationCap;and two pieces of Aluminum Flex lengths-one Red(exhaust),and one Green(air intake).See chart for diameters /i p and lengths. Ai= ,. . A B CAP CAPSIZE ORDER# STOCK# (RED FLEX EXHAUST) (AIR INTAKE) STYLE 18,.E 4"x 6 5/8" 46DVA-CL33-25 810014029 3"x 25' 3"x 25' HIGH-WIND h~18"—.1 f 1 . . 4"x 6 5/8" 46DVA-CL33 810001270 3"x 35' 3"x 35' HIGH-WIND 'Ffl�1 18" 4"x 65/8" 46DVA-CL33H 810001271 3"x 35' 3"x 35' HIGH-WIND L 4"x 65/8" 46DVA-CL34 810001272 4"x 35' 3"x 35' HIGH-WIND I'll'l 12}8" �inn 9,3_/8" 4"x 65/8" 46DVA-CL33P 810001277 3"x 35' 3"x 35' PRAIRIE mow r.: i1--1 4"x 65/8" 46DVA-CL34P 810001278 4"x 35' 3"x 35' PRAIRIE OB 0A f OA 0B 800-835-4429 1 DuraVent 231 DirectVentPro I DirectVent Direct Vent Factory-Built Use when installing a direct ventco-linear insert into an existing Reline Kit factory-builtchimney. Kit includes:High-Wind TerminationCap,Two pieces of 11 01050 Aluminum Flex Lengths,and 4 hose clamps. 11011M IT, A CAP SIZE ORDER# STOCK# (RED FLEX B Plate CAP • ■- +T EXHAUST) (AIR INTAKE) Dimension STYLE + 4"x65/e" 46DVA-CL33KFB 810007970 3"x35' 3"x35' 14" HIGH WIND r 4"x 6 5/8" 46DVA-CL34KFB 810009663 4"x 35' 3"x 35' 14" HIGH-WIND 1400 Offset Chart SIZE 4"x65/e" 5"x8" Elbow Chimney Offset Rise Offset Rise Degrees Section Inches Inches Inches Inches 30° 0" 3 5/8" 14 7/8" 3 5/8" 14 7/a" � 30° 6" 5'/s" 203/a" 5'/a" 203/a" 0 30° 9" 7 3/8" 213/8" 7 3/8" 21 3/a" 30° 12" 8'/s" 237/8" 8'/s" 23'/8" 30° 18" 11 7/a" 29'/e" 11 /e" 29'/8" A ': RISE 30° 24" 14 7/s" 32 14 7/s" 32 rilli. 30° 36" 207/s" 443/4" 207/s" 443/4" 30° 48" 267/s" 55'/8" 267/s" 551/8"i OFFSET 30° 60" 327/s" 65 Y?" 327/s" 65'Y2" 45° 0" 5" 13 V?" 5 s/e" 15 3/8" 45° 6" 8 Ya" 16 5/s" 87/s" 18 3/s" 45° 9" 101/4" 183/4" 107/s" 205/8" 45° 12" 123/a" 207/8" 13 207/8" 45° 18" 165/8" 25 1/8" 165/8" 225/8" 45° 24" 207/s" 293/a" 21 3/8" 31 Y8" 45° 36" 293/8" 377/8" 297/8" 393/8" 45° 48" 377/8" 463/s" 38Ys" 477/a" 45° 60" 463/8" 547/8" 465/8" 55 Y2" 60° 0" 6 Y8" 12'/4" 6 Ya" 12'/4" 60° 6" 10 Y8" 141/z" 101/8" 141/?" 60° 9" 12 5/s" 16 12 5/s" 16 60° 12" 151/4" 17 Y2" 151/4" 171/2" 60° 18" 20 Y?" 201/7" 20 Y?" 20'/?" 60° 24" 25 5/s" 231/7" 25 5/s" 231/?" 60° 36" 36 29 Y?" 36 29'/?" 60° 48" 46'/?" 35'/?" 46'/?" 35'/?" 60° 60" 567/8" 41Y2" 567/8" 413/2" 232 DuraVent 1 www.duravent.com