Loading...
HomeMy WebLinkAboutB18-0406 approved plans.pdf• --R 5I~ 01 8 ~ Sl ~ l5' tr' ~ ~ ~' ~ H <-0 z ~-~ Jf1 --< w --< rn c: z_ ~ .. f <;;--Cj'\ ---~ . ~ c:. C) ~ ,.._ -~ CJ --; ~v --0 ~ ~<-8 ~ ~~ _6_ ~-----/~\ :::::---RArtlJ G-1<1t1~A ""'""' . .s;, "'x C _y/J ("". A) ~ l(&a. 'lJ ~ IJ j;: I Z "tO IJ~ /)c.1 c Te() OvT J104 ~II!:} /Jvc1 CtJHNoT PEw~ilfrl1i° /(t'T£u c~ILt1t1& t,/1Tl/0~7 /I /!17EtJ CHt1J6 ENCL7Jvt1.l:i. "rD D ' :· I 1' I I I B 0 ::tl G) z > r 11 r 0 0 ::tl IJ r > z / \ ~' Town of Vail OFFICE COPY ~-t I ' ' rown oi Vail REVI . WED FOR CODE COM.LIANCE Date ~ ... .ZI ·If' RECEIVED ~t.t' ·, 4 2018 Town of Vail By: .. 1 ?.~ CodJi IS=---·----I i l ~ ~ ::}-~ ' \)o ----(11 Environmental Development and Training ACM LLC. September 12, 2018 Mike Dowling C.A.E Abatement LLC Box 5110 Eagle, Co 81631 P. 0. Box 452 Wheat Ridge, CO 80034 Phone 303-638-3 778 Site: Unit #165 of 525 Vail Valley Drive, located in Vail , Colorado. Task: Asbestos Visual and Air Clearance testing of unit 165 abatement of asbestos containing textured wall and ceiling material. The abatement Contractor removed the identified asbestos containing drywall texture ceiling and wall materials within a single full containment system. Clearance testing was conducted post removal of identified asbestos containing materials, and prior to planned repair and renovation of unit loss area. Task 1 -Field Work: 1.0 Asbestos Clearance Project Scope of Work Conducted during Air Monitoring: A. Contractor conducted abatement according to Colorado Regulation 8, EPA, and OSHA containment work practices for OSHA clearances. B. Completion of final inspections, for applicable ACM removal, and removal of all materials, within the regulated areas. Environmental Development & Training, ACM LLC (EDT) conducted a post abatement visual investigation at the above-referenced site. The investigation was conducted to discern the successful removal of ACM material using applicable State of Colorado Regulation 8, OSHA, and EPA regulations. 2.0 SAMPLE COLLECTION METHODS EDT ACM LLC used NIOSH method 7400, 40 CFR 763 AHERA and OSHA 29CFR 9010 methodology during activities to support abatement activities. FINAL AIR SAMPLES: Clearance air sampling was conducted according to Colorado Regulation 8. All of the clearance samples collected within the work area were less than 0.0 l F/CC, (fibers per Cubic Centimeter. No concentrations were observed in excess of the Maximum Allowable Asbestos Level (MAAL). 3.0 CONCLUSIONS Based on observations during the site visit, and the laboratory analytical results, EDT LLC ACM concludes the following: All Environmental and Final work Area or Clearance Air samples collected outside and inside the regulated work area clearance criteria indicated; fiber concentrations less than or equal to 0.01 flee (fibers per cubic centimeter of air sampled). No fiber concentrations were observed in excess of the Maximum Allowable Asbestos Level (MAAL) per CDPHE. Based on sampling and analysis results attached, no further action is recommended or required for this phase of the project for the impacted areas. As additional abatement items are addressed environmental and clearance air monitoring should be performed according to Colorado and EPA Regulations. 4.0 LIMITATIONS Limitations Environmental Development and Training ACM LLC prepared this report, for the exclusive and present use of CAE Abatement and DRS . This report addresses certain physical characteristics of the site with regards to the release or presence of asbestos in limited, client determined, areas only. These services were performed in a manner consistent with practices common in the environmental health profession. The information and conclusions provided herein are valid only with respect to the specific locations and analytes investigated at the time this report was prepared. The findings, conclusions, and recommendations presented here are based on information available at the time the site was evaluated. In the event of any reuse or publication of any portion of this report, Environmental Development and Training ACM LLC shall not be liable for damages arising out or such reuse of publication. Any reuse a third party makes of this report, or any reliance on or decisions made are the responsibility of such third party. Environmental Development and Training ACM LLC accepts no responsibility for damages, if any, suffered by any third party as the result of decisions made or actions taken based on this report. ~'"4 7. ')(/~ Kris Thomas Wilson President Environmental Development and Training ACM LLC Environmental Development and Training ACM LLC Phone 303-638-3778 Bob Regan 210-1349 5177 South Ventura Way Centennial, CO 80015 R2 Samgle # Xl-BL-01 Xl-BL-02 Xl-CLR-03 Xl-CLR-04 Xl-CLR-05 Xl-CLR-06 Xl-CLR-07 AIHA Laboratory Certification Colorado Laboratory Certification R2 Analytical Job Number Client Client Project Number Date/ Time Logged In Analysis Due Analysis Requested f/mm2 flee R2 LAB ID Volume(L) #Fields #Fibers Fiber Density Fiber Concentration BL-I 0 100 0 BL-2 0 100 0 595Cl-3 553 100 6.0 0.006 595Cl-4 553 100 4.5 0.006 595Cl-5 553 100 6.5 0.006 595Cl-6 553 100 4.5 0.006 595Cl-7 553 100 4.0 0.006 •BDL-Below Limit of Detection #156492 #14903 R59509122018-1 595X-l 595DX-1 09/12/2018@2020hrs 2 Hour Rush NIOSH 7400 A-Rules flee & f/mm2 Detection Limit 0.005 BDL 0.004 BDL 0.005 BDL 0.004 BDL 0.004 BDL