HomeMy WebLinkAboutB18-0125_Approved Plans_1524676711.pdf NOTES: \ 7 1.J 141 M. 1. THE WIRELESS COMMUNICATION FACILITY COMPLIES WITH FEDERAL STANDARDS \ /- 4 FOR RADIO FREQUENCY IN ACCORDANCE WITH THE TELECOMMUNICATION ACT OF ♦\ WTI 1996 AND SUBSEQUENT AMENDMENTS AND ANY OTHER REQUIREMENTS IMPOSED BY STATE OR FEDERAL REGULATORY AGENCIES. /"" • \ - `♦ /'' l 2. NO EXISTING PARKING STALLS ARE BEING ADDED OR REMOVED AS PART OF THE /'' \\ ♦♦\ \ /'' S p r ��� V NEW INSTALLATION. �♦ 3. THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND X', \\ \ SURVEY.ALL PROPERTY LINES,EASEMENTS,SETBACKS,AND EXISTING CONDITIONS /'' 04/25/18 ARE APPROXIMATE AND SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. ♦♦ 4. NO GRADING WORK IS INCLUDED IN THIS SCOPE OF WORK ON THIS PAGE /// ♦\ ♦\ • /'- \`\ \ 40\ s, e %OAPS \ '' \ , 14.4 OM 7' \ / \ \ / '/ \ m.squared - \ /'' \ \ ENGINEERS /''/ \ \ ♦♦>/'- ,)( \♦ /' \♦\ SANCLEMLEEN TE,CA92673 \ ,-- .43 / / ♦ (619)997-4012 • /' �' \ \\\ \\\ .• ♦ /'' \\\ DRAWN BY: DM • `\ ♦\yy �• / 1 kit /„ CHECKED BY: MM • • • • ♦♦• / Q• 1F ♦ /' O / \ t ■ LOWER • \ O\. `' it ♦0.°4. UPPER L� NI,. ♦♦ Oar I \\\ \ F I�i�� `�h1mlV\j .• G �� ♦ #°v. ROOF y. pH ' \ 1/0"• .„,?....• �• (E)GRASS Lv� 1O \ • ♦♦ '4 �.' 44 / ' 1 03/05/2018 100%CD'S-REVISED • §-1 ) �� q) O ��-`:v �G ♦ V. r' \ P/ .• AREA V ,, ♦ �d��� E) • SPRIN EQUIPMENT AND©© �, 0 10/30/2017 100%CD'S—BP SUBMITTAL 9� /�� ANTENNA AREA REFER TO qqq��, ♦ ` .� `Qf/!.- ♦•, \ �� A 08/07/2017 90%CD FOR REVIEW ♦♦` / .� /-' REV DATE DESCRIPTION � 111111;1° ♦♦ .�• / LOWER TP la: >► / 0 ' ' 8, T�\0... \ ROOF ♦♦ ////.� \\ ' /-' ! \ ,11: et— zi},r,. / �O / �♦���` �%�pDO LIC hll iri / %0 F 11 t 9 epyA. 014.%. 10 0 -\., \ / /// / / / ��V / 3527' • � V v\ �/ �� 7-- Aid AREA / / /' `+, ... � /, / 6/,,,,,,,....S 101V . G -- % `�p_\ APN:2103-123-02-025 /-' IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY /'' ♦ ARE ACTING UNDER THE DIRECTION OF A LICENSED /'/ / /" /'e ,I " `\\ /'- PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. /'/ / /-' ! • , (E)BUILDING ' / / /� \ /'- 2077 NORTH FRONTAGE RD /' /' • ' VAIL,CO 81657 p ROOFTOP II r �/ / / , SHEET TITLE / /'' N w(-1 E 0.. `��/ �, N SITE PLAN AND /, /'' /' ENLARGED SITE PLAN ok L `J6 SHEET NUMBER S S A_1 SITE PLAN 11"x36" SCALE: 1" = 100,-0" 0. 5r 1 ENLARGED SITE PLAN 24"x36" SCALE: 1/16" = 1'-0" 8' 1 6' 11"x17" SCALE: 1/32" = 1'-0" 1 f • 2 'LP OW In% i i 1 NN \ \ \\\\\ N\\\ 0 / S p r 3,�D 04/25/18 \\\\\ \\\ \ \\\\\\\\\\ \ \\\\\\\\ (E)RESTROOMS \ \ \ \ - �\\ N'NN (E)SPRINT ACCESS DOOR \ \ --_ 1iE�\ �i t (E)SPRINT EQUIPMENT ROOM N ° ��� \ i"�iii, N ° m.squared \ - ENGINEERS \< (E)SPRINT MMBS CABINET `, ' 1387 CALLE AVANZADO \ SAN CLEMENTE,CA 92673 (619)997-4012 ° • (E)SPRINT BBU CABINET \ (E)SPRINT GPS ANTENNA "—CNN \ N @ \ (E)SPRINT 200A PPC CABINET wI (E)SPRINT CABLE TRAY — .. 7) I' J ° \ (E)SPRINT TELCO CABINET / g '--- \ DRAWN BY: DM CHECKED BY: MM (E)SPRINT HYBRIFELX CABLES \ -- WvIuLR\ MI (E)SPRINT GEN.PLUG (E)SPRINT 200A DISCONNECT .-1 (E)SPRINT 200A METER C ll EXISTING EQUIPMENT LAYOUT 24"x36" SCALE: 3/8 - 2 ' 11"x17" SCALE: 3/16" = 1'—°" 111 1 \\\\\\\\\\\\\\ ' 1 03/05/2018 100%CD'S-REVISED 0 10/30/2017 100%CD'S-BP SUBMITTAL 1` ` A 08/07/2017 90%CD FOR REVIEW N. \ - ` / `REV DATE DESCRIPTION \N. \\ • \ / r . N, / �� I _=\VO LICE,S \ \ \\\ \\\\\\\\\\\\\\\\\ \ \\\\\\\\� ' .0.••••p•w••.•. 1 \ \ 1 I �� Nq.•. 111 �° �y 11� (E)RESTROOMS t e a' `\ (E)SPRINT ACCESS DOOR y 3527• . • • 1 \\\\\\ ii \ \ (E)SPRINT EQUIPMENT ROOM /lrl /�•NI N• •.•1,, /.,i \� 6/ 1°‘1t\/p���ENG\= \' // I �/ ON OF A LICENSED N. IT IS RE ACTING OF LAW FOR RANYEC PERSON,UNLESS THEY \° (E)SPRINT MMBS CABINET �] \ PROFESSIONAL ENGINEER,UNDER THE DTIO ALTER THIS DOCUMENT. \ ° \ ©NEW SPRINT 2.5GHz BASEBAND (E)SPRINT BBU CABINET \ a UNIT INSIDE(E)MMBS CABINET •_I \ (E)SPRINT GPS ANTENNA (N)SPRINT BATTERIES IN(E)BBU I I CABINET; \ DN40XC954 (E)SPRINT 200A PPC CABINET r - (E)SPRINTTELCOCABINET 2077 NORTH FRONTAGE RD (E)SPRINT CABLE TRAY ,„,_ ,' • ' ° \ VAI L,CO 81657 $ ° ROOFTOP l (E)SPRINT HYBRIFELX CABLES \ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \ \ \ \ \\ \\ \ SHEET TITLE • 11".---... (E)SPRINT GEN.PLUG EQUIPMENT LAYOUT (E)SPRINT DISCONNECT SWICTH ' l (E)SPRINT METER SOCKET ‘21 i5 SHEET NUMBER N NEW EQUIPMENT LAYOUT 24"x36" SCALE: 3/6 4 A-2 11"x17" SCALE: 3/16" = 1'—°" 111 2 ,, PROJECT: DO MACRO UPGRADE .54 MI ',...k,..811. ,- 44.orlo -.C-(;) 111, I ; D � 81 Iu,orrw641Nbelow. ....wb�., -. .-...k. l: Call lief ore,you dif (• I'� J N .' Q0D015 04/25/18 SITE CASCADE: DN40XC954 Spri nt \),) ADDRESS: 2077 NORTH FRONTAGE RD � � - 11/ VAIL, CO 81657 ��.. EAGLE COUNTY V VA d m.squared LATITUDE: 39.6330075° N / 39° 37' 58.82" N ENGINEERS 1387 CALLE AVANZADO LONGITUDE: 106.414855° W /106° 24' 53.47" W SANCLEMENTE,CA92673 (619)997-4012 i / SITE TYPE: ROOFTOP DRAWN BY: DM CHECKED BY: MM SITE INFORMATION AREA MAP PROJECT DESCRIPTION DRAWING INDEX allSPRINT PROPOSES TO MODIFY AN EXISTING WIRELESS INSTALLATION.THE SCOPE WILL CONSIST PROPERTY OWNER: BRANDESS ENTERPRISES LLCliv OF THE FOLLOWING: SHEET NO: SHEET TITLE P.O.BOX 3017 • REMOVE (3) EXISTING SPRINT PANEL ANTENNAS T-1 TITLE SHEET LIHUE,HI 96766-3017 • NSTALL (3) NEW SPRINT TRI-BAND PANEL ANTENNAS GN-1 GENERAL NOTES • NSTALL (3) NEW SPRINT RRU @ ANTENNA LEVEL so • NSTALL (4) NEW SPRINT BATTERIES IN EXISTING BBU CABINET GN-2 GENERAL NOTES APPLICANT: SPRINT u� • NSTALL (3) NEW SPRINT POWER JUNCTION CYLINDERS • NSTALL (3) NEW SPRINT FIBER JUNCTION CYLINDERS A-1 SITE PLAN AND ENLARGED SITE PLAN ` • NSTALL (1) NEW SPRINT 2.5GHz BASEBAND UNIT IN EXISTING MMBS CABINET A-2 EQUIPMENT LAYOUT LAT/LONG TYPE: NAD-83 • NSTALL (3) NEW SPRINT QUADPLEXER - • NSTALL (2) NEW SPRINT ANTENNA WALL MOUNTS A-3 ANTENNA LAYOUT LATITUDE: 39.633007W N/39°37'58.82"N A-4 ELEVATIONS LONGITUDE: 106.414855°W/106°24'53.47"W A-5 COLOR CODING r ZONING JURISDICTION: TOWN OF VAIL D-1 EQUIPMENT DETAILS 1 03/05/2018 100%CD'S-REVISED ZONING CLASSIFICATION: COMMERCIAL f D-2 EQUIPMENT DETAILS 0 10/30/2017 100%CD'S-BP SUBMITTAL j D-3 EQUIPMENT DETAILS CURRENT USE: UNMANNED TELECOMMUNICATIONS FACILITY c , _ A 08/07/2017 90%CD FOR REVIEW t E-1 GENERAL ELECTRICAL NOTES ASSESSOR'S PARCEL NO.: 2103-123-02-025 REV DATE DESCRIPTIONE-2 ONE-LINE DIAGRAM PROPOSED USE: UNMANNED TELECOMMUNICATIONS FACILITY E-3 PANEL SCHEDULE e N TYPE OF CONSTRUCTION: V-B { E-4 ANTENNA GROUNDING PLAN AND DIAGRAM —��� OCCUPANCY GROUP: U-2 \��� • N. . N E-5 GROUNDING DETAILS i17\ o IICFys h�, RF-1 RADIO FREQUENCY DATA SHEET •••N••••••M(CD y gild %� r'0.A• Wyq':• 16) W a E � G ��I S / 3527' _ / ••• /�, PROJECT TEAM LOCATION MAP APPLICABLE CODES APPROVALS �� F••., ..•• 4.A, REAL ESTATE MANAGER: ENGINEER: h •� -'1. ? . •rr � ..� „ r TO PROCEEDTHE WITH THE CONSTRUCTNG PARTIES HEREBY ION DESCRIBED HEREIN.ALL DOCUMENTS ARE SUBJECT TO REVIEW BY PROVE AND ACCEPT THESE DOCUMENTS&AUTHORIZE THE SUBCONTRACTOR 1��‘‘‘519/0A1 AL EN�- A _ ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CONTACT:CHRISTINE POULIGNOT M.SQUARED ENGINEERS l { �N._ CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING LOCAL BUILDING DEPARTMENT&MAY IMPOSE CHANGES OR MODIFICATIONS. \‘‘������ REAL ESTATE MANAGER-COLORADO 1387 CALLE AVANZADO - ` - p - AUTHORITIES.NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING _ SPRINT NEXTEL CORPORATION SAN CLEMENTE,CA 92673 • . -- • _• - . V-�`- TO THESE CODES: CIO CHRISTINE POULIGNOT CONTACT:MICHAEL MONTELLO r a -,. - - �; ° r Al- IT 15 A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY MAILSTOP:INCOENGJO201 EMAIL:micMI l@m2-eng.COm .•r.'; _ " d• • 2015 INTERNATIONAL BUILDING CODE SPRINT RF ENGINEER: DATE: ARE ACTING UNDER THE DIRECTION OF A LICENSED 333 INVERNESS DRIVE SOUTH • ='s` - '1+ • 2014 NATIONAL ELECTRICAL CODE PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. ENGLEWOOD,CA 80112 r • LOCAL BUILDING CODES • PH:(720)329-7993 RF ENGINEER: • 4 • • CITY/COUNTY ORDINANCES SPRINT OPERATIONS: DATE: EMAIL:christine.poulignot@sprint.com �� CONTACT:NEERAJ BERI PH:(440)222-8729 g' e SITE ACQUISITION EMAIL:neeraj.beri@sprint.com SITE ACQUISITION: DATE: M SQUARED ENGINEERS •� • - - DN40XC954 CONTACT:FELICIA PHILLIPS �' ; - CONSTRUCTION MANAGER: DATE: 2077 NORTH FRONTAGE RD 1387 CALLE AVANZADO \ - - - SAN CLEMENTE,CA 92673 CONSTRUCTION MANAGER: • VAIL,CO 81657 PH:(714)791-6643 CONTACT:BRANDON WHINERY ROOFTOP EMAIL:felicia@m2-eng.com PH:(303)505-5750 • - PROPERTY OWNER: DATE: EMAIL:brandon.whinery@sprint.com .. ala' I ZONING: DATE: • ` __ SHEET TITLE ' PROJECT MANAGER: — DATE: GENERAL NOTES I ice` • :a4 + '' TITLE SHEET THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.HANDICAPPEDSA. • Y ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2015 f " _ INTERNATIONAL BUILDING CODE.A TECHNICIAN WILL VISIT THE SITE AS '•"S'h •'1. I``'` - DO NOT SCALE DRAWINGS REQUIRED FOR ROUTINE MAINTENANCE.THE PROJECT WILL NOT RESULT IN ANY ,,,r;,41M _ .- ' w OA- \' SHEET NUMBER SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE;NO SANITARY SEWER • .t• ; 1�'-\•f4I0� SUBCONTRACTOR SHALL VERIFY ALL PLANS,EXISTING DIMENSIONS&FIELD CONDITIONS ON THE JOB SITE& T 1 SERVICE,POTABLE WATER,OR TRASH DISPOSAL IS REQUIRED AND NO - ¢ - SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE COMMERCIAL SIGNAGE IS NEW. .•A . • " WORK OR BE RESPONSIBLE FOR SAME. _ ,siti OF iv, THESE OUTLINE SPECIFICATIONS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPECIFICATIONS,INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE PERFORMED BY THE CONTRACTOR. 141 SECTION 01 100-SCOPE OF WORK: (VI)POWER CABINET,DOORS OPEN,BATTERIES INSTALLED 1.FASTENING MAIN HYBRID CABLES:ALL CABLES SHALL BE PERMANENTLY FASTENED TO THE COAX LADDER AT 4'-0'OC USING M. (VII)BREAK OUT CYLINDERS NON-MAGNETIC STAINLESS STEEL CLIPS. CC R1� THE WORK: (VIII)ASR SIGNAGE FOR SPRINT OWNED TOWERS �+ SHALL COMPLY WITH APPLICABLE NATIONAL CODES AND STANDARDS,LATEST EDITION AND PORTIONS THEREOF. (IX)RADIATION EXPOSURE WARNING SIGNS 2.FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE(MEDUSA),WITHIN THE MMBS CABINET AND �a (X) PHOTOGRAPH FROM EACH SECTOR FROM APPROXIMATELY RAD CENTER OF ANY NEW ANTENNA AT HORIZON. ANY INTERMEDIATE DISTRIBUTION BOXES: PRECEDENCE: Or SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES AND THE b.LOAD PHOTOS TO SITERRA PROJECT LIBRARY 15.IN 15 CREATE NEW CATEGORY;2.5 DEPLOYMENT AND SECTION;PERMANENT a.FIBER:SUPPORT FIBER BUNDLES USING 1/2"VELCRO STRAPS OF THE REQUIRED LENGTH O 18"OC.STRAPS SHALL BE 7 CONSTRUCTION DRAWINGS,INFORMATION ON THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE. CONSTRUCTION.LABEL PHOTOS WITH SITE CASCADE AND VIEW BEING DEPICTED.CAMERAS USED TO TAKE PHOTOGRAPHS SHALL UV,OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR S p r I01J 11 GPS ENABLED SUCH THAT THE GPS COORDINATED ARE INCLUDED IN THE PHOTO MEDIA-FILE INFORMATION. APPROVED EQUAL SITE FAMILIARITY: CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS,FIELD CONDITIONS AND COMMISSIONING: b.DC:SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH,ZIP TIES TO BE UV STABILIZED,BLACK NYLON, 04/25/18 DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. PERFORM ALL COMMISSIONING AS REQUIRED BY APPLICABLE MOPS WITH TENSILE STRENGTH AT 12,000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL. ON-SITE SUPERVISION: INTEGRATION: 3.FASTENING JUMPERS:SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES USING STAINLESS STEEL TIE WRAPS OR THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS, PERFORM ALL INTEGRATION ACTIVITIES AS REQUIRED BY APPLICABLE MOPS STAINLESS STEEL BUTTERFLY CLIPS. • TECHNIQUES,SEQUENCES,AND PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SECTION 07 500-ROOF CUTTING,PATCHING AND REPAIR 4.CABLE INSTALLATION: DRAWINGS,SPECIFICATIONS AND DETAILS REQUIRED AT JOBSITE: THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS AT THE JOBSITE FROM SUMMARY: a.INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE,NOTIFY THE CONSTRUCTION MANAGER. MOBILIZATION THROUGH CONSTRUCTION COMPLETION. THIS SECTION SPECIFIES CUTTING AND PATCHING EXISTING ROOFING SYSTEMS WHERE CONDUIT OR CABLES EXIT THE I A.DETAILS ARE INTENDED TO SHOW DESIGN INTENT.PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO PROVIDE A BUILDING-MOUNTED ANTENNAS,AND AS REQUIRED FOR WATERTIGHT PERFORMANCE.ROOFTOP ENTRY OPENINGS IN MEMBRANE b.CABLE ROUTING:CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED e---) �% ROOFTOPS SHALL BE CONSTRUCTED TO COMPLY WITH LANDLORD,ANY EXISTING WARRANTY,AND LOCAL JURISDICTIONAL IN THE CABLE ENVELOP AS INDICATED ON THE DRAWINGS. E1j :,I',.-�•.-.j COMPLETE AND FUNCTIONING SYSTEM.MODIFICATIONS MAYBE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS,AND STANDARDS. SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. c.HOIST CABLE USING PROPER HOISTING GRIPS.DO NOT EXCEED MANUFACTURERS RECOMMENDED MAXIMUM BEND IG` ?. 1.4 SUBMITTALS: RADIUS. '`.`-�. ,• 4.-/B.CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO PROCEEDING WITH THE rte% WORK.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE.MODIFICATIONS MAY BE REQUIRED TO A.PRE-CONSTRUCTION ROOF PHOTOS:COMPLETE A ROOF INSPECTION PRIOR TO THE INSTALLATION OF SPRINT EQUIPMENT 5.GROUNDING OF TRANSMISSION LINES:ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED ON DRAWINGS. o� SUIT JOB DIMENSIONS OR CONDITIONS,AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. ON ANY ROOFTOP BUILD.AT A MINIMUM INSPECT AND PHOTOGRAPH(MINIMUM 3 EA.)ALL AREAS IMPACTED BY THE ADDITION .square d OF THE SPRINT EQUIPMENT. 6.HYBRID CABLE COLOR CODING:ALL COLOR CODING SHALL BE AS REQUIRED IN TS 0200 REV 4. C.MARK THE FIELD SET OF DRAWINGS IN RED,DOCUMENTING ANY CHANGES FROM THE CONSTRUCTION DOCUMENTS. ENGINEERS B.PROVIDE SIMILAR PHOTOGRAPHS SHOWING ROOF CONDITIONS AFTER CONSTRUCTION(MINIMUM 3 EA.) 7.HYBRID CABLE LABELING:INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA-NUMERICALLY ACCORDING TO METHODS OF PROCEDURE(MOPS)FOR CONSTRUCTION: SPRINT CELL SITE ENGINEERING NOTICE-EN 2012-001 REV 4. 1387 CALLE AVANZADO CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN THE FOLLOWING INSTALLATION AND COMMISSIONING MOPS. C.ROOF INSPECTION PHOTOGRAPHS SHOULD BE UPLOADED WITH CLOSEOUT PHOTOGRAPHS. SAN CLEMENTE,CA 92673 WATERPROOFING EXTERIOR CONNECTORS AND HYBRID CABLE GROUND KITS: (619)997-4012 A.TOP HAT SECTION 09 900-PAINTING B.HOW TO INSTALL A NEW CABINET A.ALL FIBER&COAX CONNECTORS AND GROUND KITS SHALL BE WATERPROOFED. C.BASE BAND UNIT IN EXISTING UNIT QUALITY ASSURANCE: D.INSTALLATION OF BATTERIES B.WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS.ALL INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH E.INSTALLATION OF HYBRID CABLE A.COMPLY WITH COVERING CODES AND REGULATIONS,PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. F.INSTALLATION OF RRU'S BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS.USE EXPERIENCED INSTALLERS.DELIVER,HANDLE,AND G.CABLING STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1.COLD SHRINK:ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A DOUBLE WRAP OF 2"ELECTRICAL H.TS-0200 REV 4-ANTENNA LINE ACCEPTANCE STANDARDS TAPE EXTENDING 2"BEYOND TUBING,PROVIDE 3M COLD SHRINK CXS SERIES OR EQUAL. I.SPRINT CELL SITE ENGINEERING NOTICE-EN 2012-001,REV 1. B.COMPLY WITH ALL ENVIRONMENTAL REGULATIONS FOR VOLATILE ORGANIC COMPOUNDS. DRAWN BY: DM J.COMMISSIONING MOPS 2.SELF-AMALGAMATING TAPE:CLEAN SURFACES.APPLY A DOUBLE WRAP OF SELF-AMALGAMATING TAPE 2"BEYOND K.GROUNDING NE-312-201 MATERIALS: CONNECTOR.APPLY A SECOND WRAP OF SELF-AMALGAMATING TAPE IN OPPOSITE DIRECTION.APPLY DOUBLE WRAP OF CHECKED BY: MM L.SPRINT INTEGRATED CONSTRUCTION STANDARDS VERSION 4.0 2"WIDE ELECTRICAL TAPE EXTENDING 2"BEYOND THE SELF-AMALGAMATING TAPE. A.MANUFACTURERS:BENJAMIN MOORE,ICI DEVOE COATINGS,PPG,SHERWIN WILLIAMS OR APPROVED EQUAL.PROVIDE SECTION 01 200-COMPANY FURNISHED MATERIAL AND EQUIPMENT PREMIUM GRADE,PROFESSIONAL-QUALITY PRODUCTS FOR COATING SYSTEMS. 3.3M SLIM LOCK CLOSURE 716:SUBSTITUTIONS WILL NOT BE ALLOWED. , 1 COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE CONSTRUCTION DRAWINGS. PAINT SCHEDULE: 4.OPEN FLAME ON JOB SITE IS NOT ACCEPTABLE CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS PROTECTED AND HANDLED A.EXTERIOR ANTENNAS AND ANTENNA MOUNTING HARDWARE:ONE COAT OF PRIMER AND TWO FINISH COATS.PAINT FOR SECTION 11 800-INSTALLATION OF MULTIMODAL BASE STATIONS(MMBS)AND RELATED EQUIPMENT PROPERLY THROUGHOUT THE CONSTRUCTION DURATION. ANTENNAS SHALL BE NON-METALLIC BASED AND CONTAIN NO METALLIC PARTICLES.PROVIDE COLORS AND PATTERNS AS REQUIRED TO MASK APPEARANCE OF ANTENNAS.ON ADJACENT BUILDING SURFACES AND AS ACCEPTABLE TO THE OWNER, SUMMARY: CONTRACTOR IS RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR CONTRACTORS LOCATION. REFER TO ANTENNA MANUFACTURER'S INSTRUCTIONS WHENEVER POSSIBLE. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION IN ACCORDANCE WITH COMPANY PRACTICE. A.THIS SECTION SPECIFIES MMBS CABINETS,AND INTERNAL EQUIPMENT INCLUDING BY NOT LIMITED TO RECTIFIERS,POWER B.ROOF TOP CONSTRUCTION:TOUCH UP-PREPARE SURFACES TO BE REPAIRED.FOLLOW INDUSTRY STANDARDS AND DISTRIBUTION UNITS,BASE AND UNITS,SURGE ARRESTORS,BATTERIES,AND SIMILAR EQUIPMENT FURNISHED BY THE SECTION 01 300-CELL SITE CONSTRUCTION REQUIREMENTS OF OWNER TO MATCH EXISTING COATING AND FINISH. COMPANY FOR INSTALLATION BY THE CONTRACTOR(OFCI). NOTICE TO PROCEED: PAINTING APPLICATION: B.CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR NO WORK SHALL COMPLETE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF WORK ORDER. INSTALLATION EQUIPMENT IN EXISTING CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE 1.INSPECT SURFACES,REPORT UNSATISFACTORY CONDITIONS IN WRITING;BEGINNING WORK MEANS ACCEPTANCE OF APPLICABLE INSTALLATION MOPS. SITE CLEANLINESS: SUBSTRATE. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL,DEBRIS,AND TRASH.AT THE COMPLETION OF C.COMPLY WITH MANUFACTURERS INSTALLATION AND START-UP REQUIREMENTS. THE WORK,CONTRACTOR SHALL REMOVE FROM THE SITE ALL REMAINING RUBBISH,IMPLEMENTS,TEMPORARY FACILITIES,AND 2.COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS FOR PREPARATION,PRIMING AND COATING SURPLUS MATERIALS. WORK.COORDINATE WITH WORK OF OTHER SECTIONS. DC CIRCUIT BREAKER LABELING 1 03/05/2018 100%CD'S-REVISED SECTION 01 400-SUBMITTALS&TESTS 3.MATCH APPROVED MOCK-UPS FOR COLOR,TEXTURE,AND PATTERN.RE-COAT OR REMOVE AND REPLACE WORK WHICH A.LABEL CIRCUIT BREAKERS ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE-EN 2012-001,REV 1. 0 10/30/2017 100%CD'S-BP SUBMITTAL DOES NOT MATCH OR SHOWS LOSS OF ADHESION. A 08/07/2017 90%CD FOR REVIEW ALTERNATES: SECTION 11 800-INSTALLATION OF MULTIMODAL BASE STATIONS(MMBS)AND RELATED EQUIPMENT AT THE COMPANY'S REQUEST,ANY ALTERNATIVES TO THE MATERIALS OR METHODS SPECIFIED SHALL BE SUBMITTED TO SPRINTS 4.CLEAN UP,TOUGH UP AND PROTECT WORK. `REV DATE DESCRIPTION CONSTRUCTION MANAGER FOR APPROVAL.SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING.NO SUMMARY: VERBAL APPROVALS WILL BE CONSIDERED. TOUCHUP PAINTING: A.THIS SECTION SPECIFIES MMBS CABINETS,POWER CABINETS,AND INTERNAL EQUIPMENT INCLUDING BY NOT LIMITED TO TESTS AND INSPECTIONS: 1.GALVANIZING DAMAGE AND ALL BOLTS AND NUTS SHALL BE TOUCHED UP AFTER TOWER ERECTION WITH"GALVANOX","DRY RECTIFIERS,POWER DISTRIBUTION UNITS,BASE BAND UNITS,SURGE ARRESTORS,BATTERIES,AND SIMILAR EQUIPMENT F _ A.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS,INSPECTION AND PROJECT DOCUMENTATION. GALY",OR"ZINGIT". FURNISHED BY THE COMPANY FOR INSTALLATION BY THE CONTRACTOR(OFCI). =os%WO LICE* 1� 2.FIELD TOUCHUP PAINT SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. B.CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR i 1 B.CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 3.ALL METAL COMPONENTS SHALL BE HANDLED WITH CARE TO PREVENT DAMAGE TO THE COMPONENTS,THEIR INSTALLATION INSTALLATION NT IIN EXISTINGN CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE k• w D 11I P�� N4.••• I 1.COAX SWEEPS AND FIBER TESTS PER TS-0200 REV 4 ANTENNA LINE ACCEPTANCE STANDARDS. PRESERVATIVE TREATMENT,OR THEIR PROTECTIVE COATINGS. / •�� C.COMPLY WITH MANUFACTURERS INSTALLATION AND START-UP REQUIREMENTS. / I II MADE-FOAZIMUTH R THE PURPOSE ELEAND ICTRONIC ANTENNA ALT PROVIDE AN LIGNMENT TOOL(AAATED REPORT O�INSTALLLED AZIMUTH,CENTERLINE ANDED TO SITERRA USING A L SECTION 11 700-ANTENNA ASSEMBLY,REMOTE RADIO UNITS AND CABLE INSTALLATION SUPPORTING DEVICES: i 3527' . 7- DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA. SUMMARY: THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS,RRU'S,AND CABLE EQUIPMENT,INSTALLATION,AND TESTING OF COAXIAL A.MANUFACTURED STRUCTURAL SUPPORT MATERIALS:SUBJECT TO COMPLIANCE WITH REQUIREMENTS,PROVIDE , • • / 3.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY WORK IDENTIFIED AS FIBER CABLE. PRODUCTS BY THE FOLLOWING: II i� .• UNACCEPTABLE IN SITE INSPECTION ACTIVITIES AND/OR AS A RESULT OF TESTING. 6ANTENNAS AND RRU'S: 1.ALLIED TUBE AND CONDUIT / 111 F�s•••••••• •••\\`,. 4.ALL TESTING REQUIRED BY APPLICABLE INSTALLATION MOPS. THE NUMBER AND TYPE OF ANTENNAS AND RRU'S TO BE INSTALLED IS DETAILED ON THE CONSTRUCTION DRAWINGS. <-J, \\er 2.B-LINE SYSTEM C.REQUIRED CLOSEOUT DOCUMENTATION INCLUDES,BUT IS NOT LIMITED TO THE FOLLOWING: HYBRID CABLE: 1I1\‘�0�" ,.- HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH SITE.CABLE SHALL BE INSTALLED PER THE 3.SUNISTRUT DIVERSIFIED PRODUCTS 1.AZIMUTH,DOWNTILT,AGL FROM SUNSIGHT INSTRUMENTS-ANTENNA ALIGNMENT TOOL(ATT) CONSTRUCTION DRAWINGS AND THE APPLICABLE MANUFACTURER'S REQUIREMENTS. 4.THOMAS&BETTS IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY 2.SEEP AND FIBER TESTS JUMPERS AND CONNECTORS: ARE ACTING UNDER THE DIRECTION OFA LICENSED FURNISH AND INSTALL 1/2"COAX JUMPER CABLES BETWEEN THE RRU'S AND ANTENNAS.JUMPERS SHALL BE TYPE LDF 4,FLC 12-50, B.FASTENERS:TYPES,MATERIALS,AND CONSTRUCTION FEATURES AS FOLLOWS: PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. 3.SCANABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED EQUIPMENT CR 540,OR FXL 540.SUPER-FLEX CABLES ARE NOT ACCEPTABLE.JUMPERS BETWEEN THE RRU'S AND ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM DIELECTRIC,OUTDOOR RATED COAXIAL CABLE.DO NOT USE SUPER-FLEX 1.EXPANSION ANCHORS:CARBON STEEL WEDGE OR SLEEVE TYPE. 4.ALL AVAILABLE JURISDICTIONAL INFORMATION OUTDOORS.MAXIMUM OF 4 FEET EXCESS PER JUMPER AND HAVE CONNECTORS AT EACH END,MANUFACTURED BY SUPPLIER.IF JUMPERS ARE FIELD FABRICATED,FOLLOW MANUFACTURER'S REQUIREMENTS FOR INSTALLATION OF CONNECTORS. 2.POWER-DRIVEN THREADED STUDS:HEAT-TREATED STEEL,DESIGNED SPECIFICALLY FOR THE INTENDED SERVICE. 5.PDF SCAN REDLINES PRODUCED IN FIELD REMOTE ELECTRICAL TILT(RET)CABLES: 3.FASTEN BY MEANS OF WOOD SCREWS ON WOOD. DN40XC954 6.A PDF SCAN OF RELINE MARK-UPS SUITABLE FOR USE IN ELECTRONIC AS-BUILT DRAWING PRODUCTION MISCELLANEOUS: 4.TOGGLE BOLTS ON HOLLOW MASONRY UNITS. 2077 NORTH FRONTAGE RD 7.LIEN WAIVERS INSTALL SPLITTERS,COMBINERS,FILTERS PER RF DATA SHEET,FURNISHED BY SPRINT. VAI L,CO 81657 5.CONCRETE INSERTS OF EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY. 8.FINAL PAYMENT APPLICATION ANTENNA INSTALLATION: ROOFTOP THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDANCE WITH THE INSTRUCTIONS SUPPLIED BY THE 6.MACHINE SCREWS,WELDED THREADED STUDS,OR SPRING-TENSION CLAMPS ON STEEL. 9.REQUIRED FINAL CONSTRUCTION PHOTOS MANUFACTURER,ANTENNA HEIGHT,AZIMUTH,AND FEED ORIENTATION INFORMATION SHALL BEA DESIGNATED ON THE CONSTRUCTION DRAWINGS. 7.EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE PERMITTED. I 10.CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS A.THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE MOUNTS SO THAT THE BOTTOM STRUT IS LEVEL.THE 8.DO NOT WELD CONDUIT,PIPE STRAPS,OR ITEMS OTHER THAN THREADED STUDS TO STEEL STRUCTURES. SHEET TITLE 11.ALL POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SITERRA(SPRINTS DOCUMENT REPOSITORY PIPE MOUNTS SHALL BE PLUMB TO WITHIN 1 DEGREE. OF RECORD. 9.IN PARTITIONS OF LIGHT STEEL CONSTRUCTION,USE SHEET METAL SCREWS. 12.CLOSEOUT PHOTOGRAPHS: B.ANTENNA MOUNTING REQUIREMENTS:PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS. SUPPORTING DEVICES: GENERAL NOTES HYBRID CABLE INSTALLATION: a.PROVIDE PHOTOGRAPHS OF FINAL PROJECT PER THE FOLLOWING LIST.ADDITIONAL PHOTOGRAPHS MAY BE A. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH • REQUIRED TO SUPPORT ACCEPTANCE PROCESSES A.THE CONTRACTOR SHALL ROUTE,TEST,AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN NEC. ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES. r SHEET NUMBER N (I) MAIN HYBRID CABLE ROUTE(MINIMUM TWO PHOTOS) C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS,FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE (I) PHOTOS OF EACH ANTENNA AND RRU B.THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE MANUFACTURER'S SPECIFICATIONS FOR BENDING SECURELY TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING: (III)MANUFACTURERS NAME TAG FOR ALL SERIALIZED EQUIPMENT RADII. D. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT OF THE PROOF TEST LOAD. GN.1 (IV)PULL AND DISTRIBUTION BOXES INTERMEDIATE BETWEEN RRU'S AND MMBS(DOOR OPEN) E. USE VIBRATION AND SHOCK-RESISTANT FASTENERS FOR ATTACHMENTS TO CONCRETE SLABS. (V) MMBS CABINET WITH DOOR OPEN SHOWING MODIFICATIONS C.EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION. ELECTRICAL IDENTIFICATION: 141 A.UPDATE AND PROVIDE TYPED CIRCUIT BREAKER SCHEDULES IN THE MOUNTING BRACKET,INSIDE DOORS OF AC PANEL BOARDS WITH ANY CHANGES MADE TO THE AC SYSTEM. R1� B.BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PANELBOARD. 1a SECTION 26200-ELECTRICAL MATERIALS AND EQUIPMENT Sprap V CONDUIT: V L! A.RIGID GALVANIZED STEEL(RGS)CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN 04/25/18 UNFURNISHED INTERIOR LOCATIONS AND FOR ENCASED RUNS IN CONCRETE.RIGID CONDUIT AND FITTINGS SHALL BE STEEL, COATED WITH ZINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS.CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1,FEDERAL SPECIFICATION WW-C-581 AND SHALL BE LISTED WITH THE UNDERWRITERS'LABORATORIES. FITTING WILL NOT BE ACCEPTABLE.RGS CONDUITS SHALL BE MANUFACTURED BY ALLIED,REPUBLIC OR WHEATLAND. B.UNDERGROUND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE(PVC)SUITABLE FOR DIRECT BURIAL AS APPLICABLE.JOINTS SHALL BE BELLED,AND FLUSH SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.CONDUIT SHALL BE CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL. C.TRANSITIONS BETWEEN PVC AND RIGID(RGS)SHALL BE MADE WITH PVC COATED METALLIC LONG SWEEP RADIUS ELBOWS. i� � D.EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED FINISHED SPACES CONCEALED IN WALLS AND CEILINGS.EMT SHALL BE MILD STEEL.ELECTRICALLY WELDED,ELECTRO-GALVANIZED OR HOT-DIPPED GALVANIZED AND PRODUCED TO ANSI '� •%G,_:,` %' SPECIFICATION C80.3,FEDERAL SPECIFICATION WW-C-563,AND SHALL BE UL LISTED.EMT SHALL BE MANUFACTURED BY -„ S • ALLIED,REPUBLIC OR WHEATLAND,OR APPROVED EQUAL.FITTING SHALL BE METALLIC COMPRESSION.SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. 1 E.LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FINAL CONNECTION TO EQUIPMENT.FITTINGS SHALL BE 1 1 W 1.s q u a re d METALLIC GLAND TYPE COMPRESSION FITTINGS,MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM.SET SCREW ENGINEERS CONNECTIONS SHALL NOT BE ACCEPTABLE.MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL NOT EXCEED 6-FEET.LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRE BY NEC.MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, 1387 CALLE AVANZADO ANACONDA METAL.HOSE OR UNIVERSAL METAL HOSE,OR APPROVED EQUAL. SAN CLEMENTE,CA 92673 F.MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH(21 MM). (619)997-4012 HUBS AND BOXES: A.AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED HUBS PROVIDE METALLIC THREADED HUBS OF THE SIZE AND CONFIGURATION REQUIRED.HUB SHALL INCLUDE LOCKNUT AND NEOPRENE 0-RING SEAL. PROVIDE IMPACT RESISTANT 105 DEGREE C PLASTIC BUSHINGS TO PROTECT CABLE INSULATION. B.CABLE TERMINATION FITTINGS FOR CONDUIT DRAWN BY: DM 1.CABLE TERMINATORS FOR RGS CONDUIT SHALL BE TYPE CRC BY O-Z/GEDNEY OR EQUAL. CHECKED BY: MM 2.CABLE TERMINATORS FOR LFMC SHALL BE ETCO-CL2075;OR MADE FOR THE PURPOSE PRODUCTS BY ROXTEC. C.EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE PLATED CAST ALLOY,HEAVY DUTY, WEATHERPROOF,DUST PROOF,WITH GASKET,PLATED IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE-HINDS WAB SERIES OR EQUAL. D.CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKET COVERS.OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR THE APPLICATION.PROVIDE CROUSE-HINDS FORM 8 OR EQUAL. E.MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN,SQUARE"D",CROUSE-HIND,COOPER,ADALET,APPLETON, O-Z GEDNEY,RACO,OR APPROVED EQUAL. SUPPLEMENTAL GROUNDING SYSTEM A.FURNISH AND INSTALL A SUPPLEMENTAL GROUNDING SYSTEM AS INDICATED ON THE DRAWINGS.SUPPORT SYSTEM WITH NON-MAGNETIC STAINLESS STEEL CLIPS WITH RUBBER GROMMETS.GROUNDING CONNECTORS SHALL BE TINNED COPPER WIRE,SIZES AS INDICATED ON THE DRAWINGS.PROVIDE STRANDED OR SOLID BARE OR INSULATED CONDUCTORS AS INDICATED. B.SUPPLEMENTAL GROUNDING SYSTEM:ALL CONNECTIONS TO BE MADE WITH CAD WELDS,EXCEPT AT EQUIPMENT USE LUGS 1 03/05/2018 100%CD'S-REVISED OR OTHER AVAILABLE GROUNDING MEANS AS REQUIRED BY MANUFACTURER;AT GROUND BARS USE TWO HOLE SPADES 0 10/30/2017 100%CD'S-BP SUBMITTAL WITH NO OX. A 08/07/2017 ..........FOR REVIEW C.STOLEN GROUND-BARS:IN THE EVENT OF STOLEN GROUND BARS,CONTACT SPRINT CM FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS. REV DATE PTION EXISTING STRUCTURE: r � A.EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS,RECEPTACLES,SWITCHES,DEVICES,BOXES,AND OTHER EQUIPMENT THAT ARE NOT TO BE UTILIZED IN THE COMPLETED PROJECT SHALL BE REMOVED OR DE-ENERGIZED AND CAPPED „to. _ \on, IN THE WALL,CEILING,OR FLOOR SO THAT THEY ARE CONCEALED AND SAFE,WALL,CEILING,OR FLOOR SHALL BE PATCHED = pIICei 1N1 TO MATCH THE ADJACENT CONSTRUCTION. '' C�•. .tis/p .6 CONDUIT AND CONDUCTOR INSTALLATION: • -t/ 4 .• II ,�A.CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED.CLOSELY FOLLOW THE LINES OF THE • STRUCTURE,MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES.CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLETS OUTLET BODIES.CONDUIT SHALL BE INSTALLED IN A NEAT I :• AND WORKMANLIKE MANNER,PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES.ALL CONDUIT SHALL BE FINISHED TO CLEAR OBSTRUCTIONS.ENDS OF CONDUIT SHALL BE TEMPORARILY CAPPED TO PREVENT CONCRETE,PLASTER OR ,,� ��,•S , q DIRT FROM ENTERING.CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE F' / nS• •S 1,, ,�, AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. / III FFn./ NAL B.CONDUCTORS SHALL BE PULLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE. III*U. 0NAL ��'�\ IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OFA LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. DN40XC954 2077 NORTH FRONTAGE RD VAIL,CO 81657 ROOFTOP SHEET TITLE GENERAL NOTES SHEET NUMBER GN-2 NOTES: \ 7 1.J 141 M. 1. THE WIRELESS COMMUNICATION FACILITY COMPLIES WITH FEDERAL STANDARDS \ /- 4 FOR RADIO FREQUENCY IN ACCORDANCE WITH THE TELECOMMUNICATION ACT OF ♦\ WTI 1996 AND SUBSEQUENT AMENDMENTS AND ANY OTHER REQUIREMENTS IMPOSED BY STATE OR FEDERAL REGULATORY AGENCIES. /"" • \ - `♦ /'' l 2. NO EXISTING PARKING STALLS ARE BEING ADDED OR REMOVED AS PART OF THE /'' \\ ♦♦\ \ /'' S p r ��� V NEW INSTALLATION. �♦ 3. THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND X', \\ \ SURVEY.ALL PROPERTY LINES,EASEMENTS,SETBACKS,AND EXISTING CONDITIONS /'' 04/25/18 ARE APPROXIMATE AND SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. ♦♦ 4. NO GRADING WORK IS INCLUDED IN THIS SCOPE OF WORK ON THIS PAGE /// ♦\ ♦\ • /'- \`\ \ 40\ s, e %OAPS \ '' \ , 14.4 OM 7' \ / \ \ / '/ \ m.squared - \ /'' \ \ ENGINEERS /''/ \ \ ♦♦>/'- ,)( \♦ /' \♦\ SANCLEMLEEN TE,CA92673 \ ,-- .43 / / ♦ (619)997-4012 • /' �' \ \\\ \\\ .• ♦ /'' \\\ DRAWN BY: DM • `\ ♦\yy �• / 1 kit /„ CHECKED BY: MM • • • • ♦♦• / Q• 1F ♦ /' O / \ t ■ LOWER • \ O\. `' it ♦0.°4. UPPER L� NI,. ♦♦ Oar I \\\ \ F I�i�� `�h1mlV\j .• G �� ♦ #°v. ROOF y. pH ' \ 1/0"• .„,?....• �• (E)GRASS Lv� 1O \ • ♦♦ '4 �.' 44 / ' 1 03/05/2018 100%CD'S-REVISED • §-1 ) �� q) O ��-`:v �G ♦ V. r' \ P/ .• AREA V ,, ♦ �d��� E) • SPRIN EQUIPMENT AND©© �, 0 10/30/2017 100%CD'S—BP SUBMITTAL 9� /�� ANTENNA AREA REFER TO qqq��, ♦ ` .� `Qf/!.- ♦•, \ �� A 08/07/2017 90%CD FOR REVIEW ♦♦` / .� /-' REV DATE DESCRIPTION � 111111;1° ♦♦ .�• / LOWER TP la: >► / 0 ' ' 8, T�\0... \ ROOF ♦♦ ////.� \\ ' /-' ! \ ,11: et— zi},r,. / �O / �♦���` �%�pDO LIC hll iri / %0 F 11 t 9 epyA. 014.%. 10 0 -\., \ / /// / / / ��V / 3527' • � V v\ �/ �� 7-- Aid AREA / / /' `+, ... � /, / 6/,,,,,,,....S 101V . G -- % `�p_\ APN:2103-123-02-025 /-' IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY /'' ♦ ARE ACTING UNDER THE DIRECTION OF A LICENSED /'/ / /" /'e ,I " `\\ /'- PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. /'/ / /-' ! • , (E)BUILDING ' / / /� \ /'- 2077 NORTH FRONTAGE RD /' /' • ' VAIL,CO 81657 p ROOFTOP II r �/ / / , SHEET TITLE / /'' N w(-1 E 0.. `��/ �, N SITE PLAN AND /, /'' /' ENLARGED SITE PLAN ok L `J6 SHEET NUMBER S S A_1 SITE PLAN 11"x36" SCALE: 1" = 100,-0" 0. 5r 1 ENLARGED SITE PLAN 24"x36" SCALE: 1/16" = 1'-0" 8' 1 6' 11"x17" SCALE: 1/32" = 1'-0" 1 f • 2 'LP OW In% i i 1 NN \ \ \\\\\ N\\\ 0 / S p r 3,�D 04/25/18 \\\\\ \\\ \ \\\\\\\\\\ \ \\\\\\\\ (E)RESTROOMS \ \ \ \ - �\\ N'NN (E)SPRINT ACCESS DOOR \ \ --_ 1iE�\ �i t (E)SPRINT EQUIPMENT ROOM N ° ��� \ i"�iii, N ° m.squared \ - ENGINEERS \< (E)SPRINT MMBS CABINET `, ' 1387 CALLE AVANZADO \ SAN CLEMENTE,CA 92673 (619)997-4012 ° • (E)SPRINT BBU CABINET \ (E)SPRINT GPS ANTENNA "—CNN \ N @ \ (E)SPRINT 200A PPC CABINET wI (E)SPRINT CABLE TRAY — .. 7) I' J ° \ (E)SPRINT TELCO CABINET / g '--- \ DRAWN BY: DM CHECKED BY: MM (E)SPRINT HYBRIFELX CABLES \ -- WvIuLR\ MI (E)SPRINT GEN.PLUG (E)SPRINT 200A DISCONNECT .-1 (E)SPRINT 200A METER C ll EXISTING EQUIPMENT LAYOUT 24"x36" SCALE: 3/8 - 2 ' 11"x17" SCALE: 3/16" = 1'—°" 111 1 \\\\\\\\\\\\\\ ' 1 03/05/2018 100%CD'S-REVISED 0 10/30/2017 100%CD'S-BP SUBMITTAL 1` ` A 08/07/2017 90%CD FOR REVIEW N. \ - ` / `REV DATE DESCRIPTION \N. \\ • \ / r . N, / �� I _=\VO LICE,S \ \ \\\ \\\\\\\\\\\\\\\\\ \ \\\\\\\\� ' .0.••••p•w••.•. 1 \ \ 1 I �� Nq.•. 111 �° �y 11� (E)RESTROOMS t e a' `\ (E)SPRINT ACCESS DOOR y 3527• . • • 1 \\\\\\ ii \ \ (E)SPRINT EQUIPMENT ROOM /lrl /�•NI N• •.•1,, /.,i \� 6/ 1°‘1t\/p���ENG\= \' // I �/ ON OF A LICENSED N. IT IS RE ACTING OF LAW FOR RANYEC PERSON,UNLESS THEY \° (E)SPRINT MMBS CABINET �] \ PROFESSIONAL ENGINEER,UNDER THE DTIO ALTER THIS DOCUMENT. \ ° \ ©NEW SPRINT 2.5GHz BASEBAND (E)SPRINT BBU CABINET \ a UNIT INSIDE(E)MMBS CABINET •_I \ (E)SPRINT GPS ANTENNA (N)SPRINT BATTERIES IN(E)BBU I I CABINET; \ DN40XC954 (E)SPRINT 200A PPC CABINET r - (E)SPRINTTELCOCABINET 2077 NORTH FRONTAGE RD (E)SPRINT CABLE TRAY ,„,_ ,' • ' ° \ VAI L,CO 81657 $ ° ROOFTOP l (E)SPRINT HYBRIFELX CABLES \ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \ \ \ \ \\ \\ \ SHEET TITLE • 11".---... (E)SPRINT GEN.PLUG EQUIPMENT LAYOUT (E)SPRINT DISCONNECT SWICTH ' l (E)SPRINT METER SOCKET ‘21 i5 SHEET NUMBER N NEW EQUIPMENT LAYOUT 24"x36" SCALE: 3/6 4 A-2 11"x17" SCALE: 3/16" = 1'—°" 111 2 F d•4 _"....;40194014:. NOTE: .0" 414 Or 10 1. M.SQUARED ENGINEERS ACCEPTS NO LIABILITY FOR THE STRUCTURAL CAPACITY OF \ I NEW OPTIMAL ANTENNA REQUIREMENTS ANTENNA MAKE AND MODEL RAD CENTER AZIMUTH TRANSMISSION LINE . CC It THE TOWER STRUCTURE,MOUNTS,ANTENNAS,CABLES OR ANY OTHER I REMOTE RADIO UNITS DC CABLES (VERIFY WITH CURRENT RFDS) APPURTENANCE ON THE TOWER.THE CONTRACTOR AND SUBCONTRACTOR SHALL / �) MI COORDINATE WITH AND COMPLY WITH THE PROVISIONS OF THE STRUCTURAL ANTENNA RRUS ANTENNA ANTENNA CABLE CABLE RRUS MAKE AND MODEL LENGTH AWG TECHNOLOGY EXISTING NEW EXISTING NEW EXISTING NEW FEEDER TYPE ANALYSIS PREPARED FOR THIS SITE AND PROJECT PRIOR TO THE INSTALLATION OF POSITION COUNT POSITION COUNT LENGTH QTY. ANTENNAS AND CABLE ON THE TOWER.IMMEDIATELY REPORT ANY DISCREPANCIES < 1 (0) 800MHz RRU 1 - - a 1 800MIz/1900/2500MHz 1 KMW ET-X-TU-42-15-37-18-IR CCI HPA65R-KE4A4-K 34.-7" 34'-7" 40° 40' ±10' 9/1 (N) JUMPER/RET4211 BETWEEN THE CONSTRUCTION DRAWINGS AND THE STRUCTURAL ANALYSIS TO SPRINT. [e 2 (0) 1900MHz RRU 1 - - [e 2 - - - S p r J-� 2. REFER TO THE STRUCTURAL ANALYSIS AND/OR STRUCTURAL LETTER FOR THE OO011 APPROVAL OF ALL MODIFICATIONS TO AND ADDING EQUIPMENT OF NEW TOWER w 3 (N) 2.5GHz RRU 1 - - w 3 - - - - - - - - - - - Q0J APPURTENANCES. m 4 - - - - m 4 - - - - - - - - - - - 3. REFER OULDTHADDITIONAL REQUIREMENT SPECIFIC NTT TOWER REINFORCEMENT. FOR THIS SITE 1 (0) 800MHz RRU 1 - - m 1 W0&B/1900/250E$AHz 1 KMW ET-X-TU-42-15-37-18-IR CCI HPA65R-KE4AA-K 39.-7" 39'-7" 140° 140' ±10' 9/1 (N) JUMPER/RET 04/25/18 SHOULD THERE BE A REQUIREMENT FOR ANY TOWER REINFORCEMENT. m 4. REFER TO STRUCTURAL ANALYSIS FOR COAXIAL AND OTHER CABLE SUPPORT AND m0 2 (E) 1900MHz RRU 1 - - p 2 - - - - - - - - - - - CONFIGURATION DETAIL. P 5. REFER TO STRUCTURAL ANALYSIS FOR ALL CARRIERS APPURTENANCES AS THEY MAY w 3 (N) 2.5GHz RRU 1 - - w 3 - - - - - - - - - - - NOT BE SHOWN IN ELEVATION DETAIL. m 4 - - - - 4 - - - - - - - - - - - • 0 I (0) 800MHz RRU 1 - - 0 1 800Mz/1900/2500MHz 1 KMW ET-X-TU-42-15-37-18-IR CCI HPA65R-KE4AA-K 34'-5" 34'-5" 230° 230' ±10' 9/1 (N) JUMPER/RET r 1 NOTES TO CONTRACTOR: O 2 (E) 1900MHz RRU 1 - - 2 - - - - - - - - - - - NOTE: w 3 (N) 2.5GHz RRU 1 - - w 3 - - - - - - - - - - - 1. CONTRACTOR IS TO REFER TO SPRINT'S MOST 1. (E)ANTENNA AZIMUTHS ARE ESTIMATED AND ARE N 4 - - - - N 4 - - - - - - - - - - - Cal /y CURRENT RADIO FREQUENCY DATA SHEET(RFDS) TO BE VERIFIED BY RF. 1�R; Oa PRIOR TO CONSTRUCTION ��!1; �_ti,1 2. CABLE LENGTHS WERE DETERMINED BASED ON 2. ALL NEW FIBER/CABLE RUNS TO UTILIZE(E) ' _; VISUAL INSPECTION DURING SITE-WALK. .� :=*-,, - CONDUIT PATHS PREVIOUSLY ESTABLISHED WITHIN �`'� CONTRACTOR TO VERIFY ACTUAL LENGTH A PRE-APPROVED ACCESS/UTILITY ROUTE. rte/ 9 • DURING PRE-CONSTRUCTION WALK \/ •� 3. CONTRACTOR TO VERIFY PORTS HAVE SUFFICIENT ROOM 1 1 W1 1.s q u a re d ENGINEERS NOTES1387 CALLE 2 SAN CLEMENTE,CA 92673 (619)997-4012 NOTE: 1. ALL NEW ANTENNAS WILL BE PAINTED TO MATCH THE BUILDING A,ii, b� DRAWN BY: DM SZs JR '�<S CHECKED BY: MM i 1 (N) E) 800/1900/2500MHz /p,800/1900MHz (E)SPRINT 800/1900MHz DUAL BAND ANTENNA 40" �ak©© /// , 40" ' MOUNTED ON(E)PIPE TO BE REMOVED AND //A/ /�, 4� (N)SPRINT TRI-BANDPANEL ANTENNA ,, f./ REPLACED;(2)TOTAL ,, TO BE MOUNTED ON(N)PIPE;(2)7OTAL��WW (E)SPRINT 800MHz RRU MOUNTED BEHIND /// (E)SPRINT 800MHz RRU MOUNTED BEHIND ///// ��,,, (E)SCREENING;(1)PER SECTOR,(3)TOTAL // (E)SCREENING;(1)PER SECTOR,(3)TOTAL /// /' �,,, (E)SPRINT 1900MHz RRU MOUNTED BEHIND / , / // '�� , (E)SCREENING;(1)PER SECTOR,(3)TOTAL // (E)SPRINT 1900MHzG;(1) RRU MOUNTED BEHIND // //��' /, (E)SCREENING;(1)PER SECTOR,(3)TOTAL /// //d r- �,. /,, (N)SPRINT FIBER JUNCTION CYLINDER /// /i/ '�'•.4 ,,. (N)SPRINT 2500MHz RRU TO BE WALL©� // / / ;' '' ,,, MOUNTED TO ANTENNA PIPE MAST;(1) /// /// /:'444 S MOUNTED;(1)PER SECTOR,(3)TOTALU � / 04Z- AS PER SECTOR,(3)TOTAL /// /// 44 44, ,,, Gam.' ©© /// /i ♦'4• ; (N)SPRINT (3)BTOTAL�ah 1 03/05/2018 100%CD'S-REVISED // // �i COOT C ®® / �/ //, , l ,, �W 0 10/30/2017 100%CD'S-BP SUBMITTAL //// ,/ //�/ 1111 ��\- (N)SPRINT POWER JUNCTION CYLINDER , ,/fr / / 1111 A 08/07/2017 90%CD FOR REVIEW ` .. �// `/ MOUNTED TO ANTENNA PIPE MAST;(1) / , '' // // •144, (E)SPRINT 800/1900MHz DUAL BAND P®C®(3)TOTAL �`/§.14, '''' // ,, MOUNTED ON(N)PIPE INSIDE(E) REV DATE DESCRIPTION 14,k �'',. -. , ,, ANTENNA MOUNTED INSIDE STEALTH TUBE `, ' ,// /,, (N)SPRINT TRI-BAND PANEL ANTENNA TO BE REMOVED AND REPLACED;(1)TOTAL ©© 1/' , STEALTH TUBE;(1)TOTAL r 800/12300 H 111,1 '''�'.�//// ,,I,, (E)ANTENNASBYOTHERS (N) 1111, '''�'./i/// ,,/�, ww� =��ppDO IICFysz�h�� II , 800/1900/2500MHz , n , or �%�........qM('D 1,/ 111,,1, rim(E) /1111`, �O�ry�O 230' /11•11, �I 1111,\, (E)ANTENNAS BY Oor •THERS4. ������p. Wy �•� /,, ,1,, 800/1900MHz ,,1 4C' •Z,' `,�, (' ( ) /, (E)ROOFTOP LADDER ACCESS ,, �1 800/1900/2500MHz ,,, 3527• _ ,1,,, ,,,,,� _1>�J (E)ROOFTOP LADDER ACCESS ,,, 140" P' i• / AO"' • 40 Alt.Jr 6/ ,. 8,,_.... •..c ,e- c �j1 /// Ilk T /// fi n IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY .cO`_S. ,/ // 0/, rill ARE ACTING UNDER THE DIRECTION OF A LICENSED C ..(X\% ,,1 // , // PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. 0�\�J 1111.. ////// -.9''‘,"S\ ,,,,�� ////// ,i- 141/4 (E)ANTENNA BY OTHERS /, //l 'Cj s (E)ANTENNA BY OTHERS ,, // FC ,,, //// �y Off° ,,, illi / Gj, DN40XC954H �, , / ll �G C), �� /l ti�p�" 2077 NORTH FRONTAGE RD y VAIL,CO 81657 ,,/� ���, ,�,/di �° ROOFTOP (E)ANTENNAS BY OTHERS (E)ANTENNAS BY OTHERS SHEET TITLE N N ANTENNA LAYOUT 6 �I► W E W E SHEET NUMBER S s A-3 EXISTING ANTENNA LAYOUT 11x36"" SCALE: 3/16" = 0" f 1 NEW ANTENNA LAYOUT 24"x36" SCALE: 3/16" - - ■■ 4 R 11"x17" SCALE: 3/32" = 1'-0" C IN f i 2 AS OF if, 40. NOTE: (E)SPRINT 800/1900MHz DUAL BAND TOP OF EXISTING STEALTH TUBE e +0 1. ALL NEW ANTENNAS WILL BE PAINTED TO MATCH ANTENNA MOUNTED INSIDE STEALTH TUBE / ELEV.±43'-4"AGL {.dOr VL THE BUILDING TO BE REMOVED AND REPLACED;(1)TOTAL M TOP OF EXISTING SPRINT PANEL ANTENNAS gig ELEV.±41'-7"AGL RTI _ _ RAD CENTER OF EXISTING SPRINT PANEL ANTENNASUV ELEV.±39'-7"AGL TOP OF EXISTING BUILDING l^ VIELEV.±36'-10"AGLS7 TOP OF EXISTING SPRINT PANEL±NTENNAS #Q0^� 11 ELEV.ANTE"AGL RAD CENTER OF EXISTING SPRINT PANEL ANTENNAS Ii ELEV.34'-5"AGL 04/25/18 (E)SPRINT 800/1900MHz DUAL BAND ANTENNA /1/_ MOUNTED ON(E)PIPE TO BE REMOVED AND REPLACED;(2)TOTAL N (E)ANTENNAS BY OTHERS 1 (E)ROOFTOP LADDER ACCESS Cal t2 EXISTING EQUIPMENT PLATFORM LEVEL ':.:±.”.-5 �ti A ELEV.24'-0"AGL 1`r/ m.squared ENGINEERS 1387 CALLE AVANZADO SAN CLEMENTE,CA 92673 (619)997-4012 -• i ' )E)SPRINT EQUIPMENT ROOM ACCESS DOOR / DRAWN BY: DM f./ / (E)SPRINT METER SOCKET .4.--.-_,,,, // CHECKED BY: MM (E)SPRINT DISCONNECT SWITCH \ �(�� TD'- (E)SPRINT GEN.PLUG / 1 GROUND LEVEL ELEV.0'-0"AGL EXISTING SOUTHEAST ELEVATION 24"x36" SCALE: 3/16" = 1,-0" 2' 4' 8' 11"x17" SCALE: 3/32" = 1'-0" ® 1 NOTE (N)SPRINT TRI-BAND PANEL ANTENNA TOP OF EXISTING STEALTH TUBE 1. ALL NEW ANTENNAS WILL BE PAINTED TO MATCH MOUNTED ON(N)PIPE INSIDE(E) / ELEV.±43'-4"AGL THE BUILDING ��� STEALTH TUBE;(1)TOTAL 1 03/05/2018 100%CD'S-REVISED TOP OF NEW SPRINT PANEL ANTENNAS * ELEV.±41'-7"AGL 0 10/30/2017 100%CD'S-BP SUBMITTAL _RAD CENTER OF NEW SPRINT PANEL ANTENNAS A 08/07/2017 90%CD FOR REVIEW - — ELEV.±39'-7"AGL `REV DATE DESCRIPTION TOP OF EXISTING BUILDING ELEV.±36'-10"AGL TOP OF NEW SPRINT PANEL ANTENNAS r 1 IN O _ _ _RAD CENTER OF NEW SPRINT PANEL ELEV.34'SNAGLL� p�pDO IICF\‘‘ 1 ©�©© (N)SPRINT TRI-BANDPANEL ANTENNA .0",\\.T`" ^' rY/7A~••• ,I .•Q� / I ��m � TO BE MOUNTED ON(N)PIPE;(2)TOTAL (E)ANTENNAS BY OTHERS % ? �' ,� • (E)ROOFTOP LADDER ACCESS i 3527 EXISTING EQUIPMENT PLATFORM LEVEL A11004,'.b f ELEV.24,0"AGL 11��•... �.����. i 1111 IUNAL EN\__ IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY / \ ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. I DN40XC954 2077 NORTH FRONTAGE RD VAIL,CO 81657 (E)SPRINT EQUIPMENT ROOM ACCESS DOOR ROOFTOP (E)SPRINT METER SOCKET II,,��II (E)SPRINT DISCONNECT SWITCH T3I (E)SPRINT GEN.PLUG r SHEET TITLE GROUND LEVEL$ ELEVATIONS ELEV.0'-0"AGL SHEET NUMBER NEW SOUTHEAST ELEVATION 24"x36" SCALE: 3/16" = 1'-0" 0" 2' 4' 8' A-4 11"x17" SCALE: 3/32" = 1'-0" fI *slti OF if, it'la 1.1% Sp r 3420] 04/25/18 • Frequency/Radio Indicator ID 800#1 Yellow Green Cal a Cal �ir.�.i 1900#1 Yellow Red `fid 1900#2 Yellow Brown o 1900#3 Yellow Blue m.squared 1900#4 Yellow Grey ENGINEERS 1387 CALLS AVANZADO 800#2 Yellow Orange � SAN CLEMENTE,CA 92673 Sec tDr Cable fidP17 eco (619)9974012 2500#1 Yellow White 1 Alpha 1 111 Ta psis No Tape ' 25x0#2 Yellow Purple .- 2 PL Tape 1•.o Tapir 1 3 No Tt pe No Tap e-- DRAWN BY: DM 1 4 Mite No Ta ie No Tape CHECKED BY: MM © 5 S AMEN No Tape 1 6 Grey Pilo Tae No Tape 1 7 Purple lci:Tape No Tape 1 8 Oran•:;: :.;L Tape No Tap 2 Beta 1 Na Tape TECHNOLOGY COLOR CODING 24"x36" SCALE: NTS 1 2 2 No 'tape 11"x17" SCALE: NTS I 2 3 No Tape 2 4 White Why NO Tape 22 ©c No Tape 1 03/05/2018 100%CD'S-REVISED 6 Grey Grey No Tape 0 10/30/2017 100%CD'S-BP SUBMITTAL � I A 08/07/2017 90%CD FOR REVIEW 2 7 My No Tap S `REV DATE DESCRIPTION I 2 8 Orange Preirrir No Tape r 2500MHz I ® 2 j,,%..............X11) #1 Cal Second 3 3 M! 9 �.•.\ A. W.............. •,, 1, Cable- Cable First Ring Ring Third Ring Forth Ring Fifth Ring Sixth Ring Ai •.•Np�i� Nq � �i Sector 3 Mite White White / I 3527' 1 Alpha 1 Yellow Yellow White 3 5 .�L 'IlII I S 2 Beta 2 Yellow Yellow Yellow White 3 6 Gfey Grey ��11'�. • �� ,, .„ 31tanma 3 Yellow Yellow Yellow Yellow White ...ft... •• •3 8 C•':':' - / 11h��/p���,V1\�= 2500MH2 I #2CCable Cal THEY Gable First Ring Second IT Third Ring Forth Ring Frith Ring Sixth Ring SREACTINGNNDLRWFORREC ION OFALICESSD ARE ACTING UNDER THE DIRECTION PER O,LICENSED Ring- PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. Sector 1 Alpha 1 Yellow Yellow Purple 2 Beta 2 Yellow Yellow Yellow Purple DN40XC954 3 Gamma 3 , Yellow Yellow Yellow Yellow PUrpie 2077 NORTH FRONTAGE RD VAIL,CO 81657 ROOFTOP SHEET TITLE COLOR CODING SHEET NUMBER -24"x36" SCALE: NTS 24"x36" SCALE: NTS A-5 2500 MHz RADIO CALIBRATION CABLE COLOR CODING „ 11"x17" SCALE: NTS 13 SAMSUNG 2.5 GHz RRH 8.03" MANUFACTURER: SAMSUNG / {J DIMENSIONS, HxWxD: 21.26'x15.03"x8.03" M. EXISTING LANANTENNA VA NEW 2"0 STD.STEEL PIPE;TYP.OF 3. WEIGHT: 59.75Ibs. i ( _-_ 1 L ` MI PROVIDE UNISTRUT P1117 PIPE WEIGHT W/ BRACKET: 71.8 LBS. r�� Jam""'"^" "'"""�L CLAMP AT EACH INTERSECTION WITH t °°°°°°° °° 44 UNISTRUT P1000 qq�� / I1} I (E)WALL 15.03" III S r Y�y `'1:2i1 • it 000co0o0o0o0o0o0o0oco0,0o =,, e ' o 111-1=0-101111 I�I� r 04125118 0 0 0 0 0 0 0 0 0000..0 NEW 3 POINT °°° °°° 3"-4 1/2"ANTENNA PIPE MAST MOUNTING AND UNISTRUT P1000; It ` t- le(:)()❑ °° °° PER PLAN DOWNTILT BRACKETTYP.OF2 ' I ° ° / o ooO000 II .■ ■. € 000S o°° oo iI NEW RRU UNIT W/TYP. ` ` I I I _ ■ = 1 1.1141.1 A.`i: 'ki F `.� *00�. MFG.PIPE MOUNTING O \_7 BRACKET;TYP.OF 3 �_ : 1 00 r /�\ /� 11\ BOTTOM VIEW SIDE VIEW FRONT VIEW -' G- c #6 AWG RRU / / (8) RF OUTPUT ( 1, rj, GROUND 1/4"HILTI KWIK-CON II+ANCHOR / PORTS W1 ROD WITH HILTI HIT-HY200 NOTES: �❑O° ❑O° Ivry} RF CALIBRATION I ■■■.squared %I ADHESIVE(ICC-ESR3187) COMPLY WITH MANUFACTURES o nV(`-"4'IL,J `t (4 PER UNISTRUT; INSTRUCTIONS TO ENSURE THAT ALL \ • PORT l`0'� IU • ENGINEERS EQUALLY SPACED) RRH'S RECEIVE ELECTRICAL POWER L,❑7 o DC POWER GROUND BAR #2 AWG MOUNT STRUT GROUND WITHIN 24 HOURS OF BEING REMOVED / 0 CONNECTOR .I 1387 CALLE AVANZADO FROM THE MANUFACTURER'S AMPHENOL FIBER RET CONNECTOR SAN CLEMENTE,CA 92673 PACKAGING. DO NOT OPEN RRH MPO CONNECTORLED INDICATOR (619)997-4012 PACKAGES IN THE RAIN. PORT LAYOUT PLAN EQUIPMENT WALL MOUNT 24""x36" SCALE N15 6 (N) 2.5 GHZ RRU 24"x36" SCALE: NTS 3 (N) AND (E) ANTENNA MOUNTING 11 x;7 SCALE NTS 1 ; ff 11"x17" SCALE: NTS MANUFACTURER: CCI MECHANICAL ' C II LI C ALU EQUIPMENT CABINET NOTE: DRAWN BY: DM • MODEL NO.: HPA65R-KE4AA-K LOCATIONS SHOWN FOR INSTALLATION OF NEW pEQUIPMENT IN EXISTING CABINET ARE MODULARITY QUAD DIMENSIONS: CONNECTOR TYPE: TOTAL MIN. CABINET CLEARANCE APPROXIMATE. ACTUAL SPACE AVAILABLE TO BE CHECKED BY: MM C A 48" (6) 7/16" DIN (FEMALE,WEIGHT : VERIFIED IN FIELD ON A SITE BY SITE BASIS. WEIGHT W/ BRACKETS 14.4 LBS (6.6KG) N /1 m B 11.7" CONNECTOR LOCATION: RF CABINET 6.26X7.42X8.17 in. - 28.7 LBS (159X188.5X207.4mm) C 7.6 BOTTOM - FRONT- 72" - REAR- 72" ELECTRICAL \O 0 0 O - LEFT- 37.8" RF PARAMETERS PORTS FREQUENCY(MHz) SPECIFICATION FRONT VIEW ESTIMATED WEIGHT: 1,074 LBS. I RETURN LOSS COMMON 1695 - 2180 18 dB min, 20 dB typ _A_ -A- _A_ _A_ PCS/AWS 1695 - 2180 18 dB min, 20 dB typ - - - - - - ,J B BRS 2496 - 2690 18 dB min, 20 dB typ INSERTION LOSS COMMON TO PCS/AWS 1695 - 2180 0.2 dB typ, 0.25dBmax COMMON TO BRS 2496 - 2690 0.2 dB typ, 0.25dBmax REJECTION COMMON TO PCS/AWS 2496 - 2690 50 dB mini COMMON TO BRS 1695 - 2180 50 dB mini _= _—_ _�_' _�_'L) ISOLATION PCS/AWS TO BRS 1695 - 2180 50 dB mini r r Y r I 1 03/05/2018 100%CD'S-REVISED BRS TO PCS/AWS 2496 - 2690 50 dB mini 0 10/30/2017 100%CD'S-BP SUBMITTAL SIDE VIEW 35.4" % A 08/07/2017 90%CD FOR REVIEW GENERAL CHARACTERISTICS 742„ _ `REV DATE DESCRIPTION General Impedance 50 ohms r / Cont.Average PWR 250 W max p ports), (Commonport) r' rt r' '' e \ g (input orts, 500 W maximum ort /'® o o .I _ / Peak Envelope PWR 1 kW max (input ports), 3 kW maximum (Common port) see. 0 0 0 'd.,.1���,, N / =`` \mak\ Intermodulation <-117 dBm (-160 dBc) at 2 x+43 dBm tones all bands ® I® �`�® r O\p�pOO LICF�/O\1111 TOP VIEW u TOP VIEW FRONT VIEW SIDE VIEW •. 1* i �it �i �0.............. 1, i •. pt). N4. % t 24"x36" SCALE: NTS 24"x36" SCALE: NTS L____ L_J / ••�' �� ,� (N) QUADPLEXER DPO-7126Y-0X1 7 (N) TRI-BAND PANEL ANTENNA o 00 00 00 0O ' 11'x17' SCALE: NTS 11"x17" SCALE: NTS u I 3527' .41 N AI • ,r \ / I •;; •;• ;!4� Noe of ":;!;• (// 11 F •.•.• TOP VIEW ❑00❑ 111 `,0NAL ,\0 .......................................: 00 00 00 00 INSTALL NEW 2.5 EQUIPMENT — IN EXISTING MMBS CABINET e r-1rvnl s e OIO2I01 e INCLUDING BUT NOT LIMITED DC LUGS DC LUGS IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY TO BASE BAND UNIT, CELL • . - , ARE ACTING UNDER THE DIRECTION OF A LICENSED SITE ROUTER AND SURGE II®® CIE En nEl E0®n nEl PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. ARRESTORS. POWER & FIBER % 1 TO BE CONNECTED jr0 0 000 0 0 0 \ GFCI ..==,. 00000 00 0 0 0 0 0 0 0_ CONCRETE PAD ` s 00001 o DN40XC954 0 0 0 0 0 0 \ 0v0h ~� 2077 NORTH FRONTAGE RD 0 0 0 0 0 o FRONT VIEW \ S'°` S'°` VAIL,CO 81657 ''( '—(—)(—) " I NEW (4) STRINGS OF ROOFTOP 0 0 0 0 0 0 0 BATTERIES TO BE INSTALLED IN EXISTING BATTERY I = 0 0 0 0 0 o BACKUP UNIT CABINET 9928 CABINET SHEET TITLE / \ EQUIPMENT DETAILS .c,-._ BOTTOM PLAN FRONT ELEVATION SHEET NUMBER NOT USED 24"x36" SCALE: NTS 11"x17" SCALE: NTS g (E) BATTERY BACKUP UNIT CABINET 4"x36" SCALE: NTS I 11"x17" SCALE: NTS 5 (E) MMBS CABINET 24"x36" SCALE: NTS I 2 , D-1 11"x17" SCALE: NTS o OF d'4, e.,- id•Or Ick 41 MI Spr1420D 04/25/18 • =Err i,.e_•:r. ig 0 1� m.squared ENGINEERS 1387 CALLE AVANZADO SAN CLEMENTE,CA 92673 (619)997-4012 NOT USED 24"x36" SCALE: NTS 4 NOT USED 24"x36" SCALE: NTS 3 NOT USED 24"x36" SCALE: NTS i 11"x17" SCALE: NTS 11"x17" SCALE: NTS 11%17" SCALE: NTS 1 DRAWN BY: ITM1 NEW 2.5 ANTENNA MOUNTING BRACKET (TYP.) CHECKED BY: MM 1111 ' �i NEW 3.0" MOUNTING PIPE NEW 2.5 ANTENNA (TYP.) MPO BOX OPTIC JUNCTION CYLINDER MPG CONNECTOR / FIBER 1 03/05/2018 100%CD'S-REVISED 0 10/30/2017 100%CD'S-BP SUBMITTAL h A 08/07/2017 90%CD FOR REVIEW `REV DATE DESCRIPTION _`D� \\\\ FIBER 2 ""1 .;\ \,.� e NEW 2.5 RRU ON PIPE MOUNT (TYP.) OR PER P �'C 1 ANTENNA PLAN MOUNTED NEAR BOTTOM '�t��•.•\•••�.• •ti F� 11) `1_� NEW 4" JUMPERS FROM RRU TO ANTENNA ••i\\�� NA•�� 11I, El NEW RET CABLE FROM RRU TO ANTENNA V 3527' I Al SINGLE ROUTE ���Ir�." �'• ���! SFP (X6) AM NEW JUMPER FROM FIBER & POWER 6, 111 ‘5.7:„..... .„� POWER „'I JUNCTION CYLINDERS TO NEW 2.5 RRU 1‘1s/pNAL EN - 6 ��� .�� — REMOVE PE PIPE CAP ON EX. FIBER & DC 6 - POWER CABLES AND CONNECT TO NEW POWER IT ISA VIOLATION OF LAW FOR UAY PERSON,UNLESS THEY & FIBER JUNCTION CYLINDERS ARE ACTING UNDER THE DIRECTION OF A LICENSED POWER 2 — PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. i POWER JUNCTION CYLINDER 11111111 DN40XC954 BT8R RRUWITO 2077 NORTH FRONTAGE RD / VAIL,CO 81657 EX. MEDUSA JUNCTION CYLINDER WITH (2) SPARE ROOFTOP DC & FIBER CABLES (TYP. PER SECTOR) 1- EX. HYBRIFLEX CABLE (TYP. PER SECTOR) SHEET TITLE EQUIPMENT DETAILS SHEET NUMBER 24x36SCALE: NTS 24"x36" SCALE: NTS f� D 2 POWER & OPTIC CYLINDER SCHEMATIC DETAIL „""x„”" SCALE: NTS I 2.5 ANTENNA/RRU CONNECTIONS, TYP. 11"x17" SCALE: NTS I L ,- 4,4 lia 10 m. ig MI 6 S p r AIep-Do 04/25/18 • 1 410 CA 0, ray 1'i.e m.squared ENGINEERS 1387 CALLE AVANZADO SAN CLEMENTE,CA 92673 (619)997-4012 NOT USED 24"x36" SCALE: NTS 11"x17" SCALE: NTS 4 NOT USED 24"x36" SCALE: NTS 11"x17" SCALE: NTS 3 NOT USED 24"x36" SCALE: NTS i / 11"x17" SCALE: NTS 1 1.5"MIN. 12" 1.5"MIN. �� DRAWN BY: DM 7 CHECKED BY: MM (N)P1000 tq Z ft:2: UNISTRUT iiiii 12"MAX i (E) PARAPET WALL L w 1 - (N)3" (N)C4X4.5 STANDOFF STD PIPE (N) 1/2"MOUNTING PLATE 12" (N)P1000 UNISTRUT 1 03/05/2018 100%CD'S-REVISED 0 10/30/2017 100%CD'S-BP SUBMITTAL iiiimiliiiiiimili A 08/07/2017 90%CD FOR REVIEW `REV DATE DESCRIPTION PARAPET WALL i _Ar iiiii iiiii 10IM 11 __N,5/3 0 o (N) ,/2 ,'.'%\\ �pUV IIIs9/hll THROUGH 1/2' li BOLT,TYP. PLATE v if ••�O.p. Wyq•••• 1I (N)C4X4.5 STANDOFF EN 0 % O ' - , /,� ',. 2 ILliki 3527' / •• ,, • i .„, , 6, .• ,,, • ,„ ..... ..ifit.if IIS/ NALE �'_ 1 0 N (N)3"STD PIPE 4" IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. OTOP VIEW SECTION , 1 12"MAX --- (N)5/8"0 _ --__ THROUGH z BOLT TYP. DN40XC954 g 2077 NORTH FRONTAGE RD EVAIL,CO 81657 ink / ;w- 5 ROOFTOP ® Z (N) 1/2.. MOUNTING in PLATE I ■ tq SHEET TITLE N)C4X4.5 STANDOFF 1.5"MIN. 12" 1.5"MIN. � EQUIPMENT DETAILS O FRONT VIEW SECTION O SIDE VIEW SECTION SHEET NUMBER (N) ANTENNA WALL MOUNT 24"x36" SCALE NTS 24"x36" SCALE: NTS D-� ` 11"x17" SCALE: NTS I 5 NOT USED 1 1"x17" SCALE: NTS I GENERAL ELECTRICAL NOTES e 414 � r IliVIe 1. SUBMITTAL OF BIO INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PREFORMED UNDER THIS CONTRACT. 513 4:1111.4.11' 18. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING PURPOSED THORUGH THE FLOOR OR WALLS FOR CONDUIT RUNS, 2. CONTRACTOR SHALL THE ACTUAL CONSTRUCTION.CCONTRACTOR SHALL FORM ALL FIELD A ISSUEWRITTEN NOTICE OF ALLN AND EXAMINATION WORK RIOR TO FINDINGS HE TO THE ENGINEER AND OWNER LISTING ALDERING OF THE ELECTRICAL L AND PIPE RUNS,ETC.,IT ANY CIRCUMSTANCES.UST CLEARLY UNDERSTOOD THAT TENDONS AND/OR REINFORCING STEEL WILL NOT BE DRILLED INTO,CUT,OR DAMAGED UNDER r 'QOJ�015 MALFUNCTIONS,FAULTY,EQUIPMENT,AND DISCREPANCIES. 19. EXACT LOCATION OF TENDONS AND/OR REINFORCING STEEL ARE NOT KNOWN AND THEREFORE MUST BE SEARCHED FOR BY APPROPRIATE 04/25/18 3. THESE PLANS ARE SCHEMATIC ONLY;CONTRACTOR SHALL FOLLOW AS CLOSELY AS POSSIBLE. METHODS,SUCH AS X-RAY EQUIPMENT OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING AND/OR STEEL TENDONS. 4. ANTENNA MOUNTING HEIGHTS AND AZIMUTHS SHALL BE VERIFIED WITH OWNER PRIOR TO INSTALLATION. 20. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WITH SUITABLE WEATHERPROOF SEALANT.PENETRATIONS IN FIRE RATED WALLS SHALL • BE FIRE STOPPED IN ACCORDANCE WITH CURRENT LOCAL BUILDING CODES USING U.L.RATED MATERIALS. 1 5. CONTRACTOR SHALL PROVIDE ALL LABOR,MATERIALS,INSURANCE,EQUIPMENT,INSTALLATION,CONSTRUCTION TOOLS,TRANSPORTATION,ETC., FOR A COMPLETE AND PROPERLY OPERATIVE SYSTEM ENERGIZED THROUGHOUT AND AS INDICATED ON DRAWINGS,AS SPECIFIED HEREIN AND/OR 21. ALL CONDUCTORS SHALL BE COPPER,#12 AWG MINIMUM.UNLESS NOTED OTHERWISE,INSULATION SHALL BE 90°C RATED,AND DUAL RATED AS OTHERWISE INDICATED.NOTE THAT CONTRACTOR SHALL SECURE ALL NECESSARY ELECTRICAL PERMITS,AND PAY ALL REQUIRED FEES. THHN/THWN-2.NO BX OR ROMEX CABLE IS PERMITTED UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS. ,. .. Cal CA Cal 1.M 6. IF REQUIRED,CONTRACTOR SHALL COORDINATE WITH LOCAL UTILITY COMPANY FOR CONNECTION OF TEMPORARY AND PERMANENT POWER TO 22. ALL CONDUIT ONLY(C.O.)RUNS SHALL HAVE A PULL WIRE OR ROPE,AND TRUE TAPE. THE SITE.THE TEMPORARY POWER AND ALL HOOK-UP COSTS SHALL BE PAID BY THE CONTRACTOR. - k4, 23. GROUND THE ENTIRE ELECTRICAL SYSTEM IN ACCORDANCE WITH THE NEC AND DRAWINGS.BELOW GRADE GROUND CONDUCTORS SHALL BE#2 )vii, ; )� 7. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AND SHALL BE OF THE BEST GRADE AND OF THE AWG SOLID BARE TINTED COPPER.ABOVE GRADE,ALL CONDUCTORS SHALL BE STRANDED GREEN INSULATED COOPER,SEIZED#2 AWG OR AS SHOWN SAME MANUFACTURER THROUGHOUT FOR EACH CLASS OR GROUP OF EQUIPMENT.EXCEPTIONS TO THIS MAY BE PERMITTED IF NEW IN THE DRAWINGS.GROUND CONDUCTOR SHALL HAVE A MINIMUM 24"BENDING RADIUS.GROUND RODS SHALL BE COPPER CLAD STEEL,5/8"ROUND m.sq uared REPLACEMENT BREAKERS OR SWITCHES ARE NOT AVAILABLE FOR ORIGINAL ELECTRICAL DISTRIBUTION EQUIPMENT--ON THAT CASE. AND 8'LONG.GROUNDING HARDWARE SHALL BE ERICO,STORM COPPER COMPONENTS,FUSHI COPPERWELD OR APPROVED EQUAL. ENGINEERS RECONDITIONED EQUIPMENT MAY BE PERMISSIBLE IF IT CARRIES ONE(1)YEAR WARRANTY.MATERIALS SHALL BE LISTED AND APPROVED BY UNDERWRITER'S LABORATORY AND SHALL BEAR THE INSPECTION LABEL"J"WHERE SUBJECT TO SUCK APPROVAL.MATERIALS SHALL MEET WITH 24. GROUND ALL ANTENNA BASES,ENCLOSURES,FRAMES,CABLE RUNS,AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT 1387 CALLE AVANZADO APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL GOVERNING BODIES HAVING JURISDICTION.MATERIALS SHALL BE MANUFACTURED IN TO THE BUS BARS.FOLLOW EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR GROUNDING.GROUND COAX SHIELD AT BOTH ENDS USING CABLE SAN CLEMENTE,CA 92673 ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY ANSI,NEMA,AND NBFU. MANUFACTURER'S RECOMMENDATIONS. (619)997-4012 8. IF CONTRACTOR IS PROPOSING ALTERNATE MATERIALS OR CONSTRUCTION METHODS FROM WHAT IS SPECIFIED IN THE PLANS,CONTRACTOR 25. THE NUMBER OF GROUNDING BARS MAY VARY DEPENDING UPON THE SITE LAYOUT,ANTENNA LOCATION,AND OTHER FACTORS.THE s., -• SHALL SUBMIT SHOP DRAWINGS AND/OR CATALOG CUT-SHEETS TO OWNER FOR APPROVAL PRIOR TO COMMENCEMENT OF THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SUFFICIENT GROUNDING BARS AS REQUIRED,PROVIDING 50%SPARE CONNECTION POINTS. 9. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL CODES AND ALL LOCAL AND STATE CODES,LAWS,AND 26. EXOTHERMIC WELDS SHALL INCLUDE ALL CABLE TO CABLE,SPLICES,CABLE TO GROUND RODS,GROUND ROD SPLICES AND OTHER SYSTEMS AS ORDINANCES.PROVIDE ALL COMPONENTS AND WIRING SIZES AS REQUIRED TO MEET NEC. INDICATED.ALL MATERIALS USED(MOLDS,WELDING,METAL,ETC.)SHALL BE INSTALLED PER MANUFACTURERS'RECOMMENDATIONS AND DRAWN BY: PROCEDURES.ALL EXOTHERMIC WELD CONNECTIONS ON GALVANIZED SURFACES SHALL BE CLEANED THOROUGHLY AND COLORED TO MATCH 10. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN EACH PANELBOARD,PULLBOX,J-BOX,SWITCH BOX,ETC.,IN SURFACE WITH(2)TWO COATS OF GALVITE(WHITE)PAINT OR SILVERBRITE(ALUMINUM). ,.CHECKED BV: MM COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION(O.S.H.A.)REQUIREMENTS. 27. ALL STRANDED COPPER WITH GREEN INSULATION TO BE ATTACHED WITH CRIMPED DOUBLE LUG,ATTACHED WITH NUTS,BOLTS AND STAR 11. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE(1)YEAR AFTER THE DATE OF JOB ACCEPTANCE BY OWNER,ANY WORK,MATERIAL WASHERS TYPICAL.ALL MECHANICAL CONNECTIONS SHALL HAVE ANTI-OXIDANT GREASE(E.G.NO-OX)APPLIED BETWEEN LUG AND BUS BAR. OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE,UPON WRITTEN NOTIFICATION,AT THE EXPENSE OF THE CONTRACTOR. 28. ALL EXPOSED TINNED COPPER GROUNDS SHALL BE PROTECTED BY 1/2"PVC CONDUIT AND SECURED.WHERE SUBJECT TO MECHANICAL DAMAGE, OTHER GROUND LEADS SHALL ALSO BE ENCLOSED IN 1/2"OR 3/4"LTFC. 12. CLEAN WORK SITE DAILY,AND REMOVE ALL DEBRIS RESULTING FROM CONSTRUCTION.LEAVE JOB SITE IN A TIDY AND UNDAMAGED CONDITION. 29. COMPRESSION FITNESS TO BE USED ON ALL CONDUITS(NO SETSCREWS). 13. UPON COMPLETION OF WORK,PERFORM CONTINUITY,SHORT CIRCUIT,AND GROUNDING TEST.GROUNDING SYSTEM SHALL BE TESTED BY INDEPENDENT TESTING AGENCY,WITH WRITTEN REPORT SUBMITTED TO THE OWNER FOR REVIEW AND APPROVAL.AFTER APPROVAL,FURNISH 30. PVC CONDUIT INSTALLED IN OUTDOOR LOCATIONS SUBJECT TO SUNLIGHT EXPOSURE SHALL BE UV RESISTANT.SURFACE-MOUNTED CONDUIT ONE COPY OF REPORT TO ENGINEER. INSTALLED IN LOCATIONS SUBJECT TO FOOT TRAFFIC OR OTHER WEAR AND TEAR,SHALL BE PVC SCHEDULE 80,IMC,OR GRC. CONDUIT RUNS ALONG WALLS OR FLOORS SHALL BE SURFACE MOUNTED UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS.OTHER CONDUIT REQUIREMENTS: 14. PROVIDE OWNER WITH ONE SET OF COMPLETE ELECTRICAL"AS BUILT"DRAWINGS AT THE COMPLETION OF THE JOB,SHOWING ACTUAL EQUIPMENT 30.a. INTERMEDIATE METALLIC CONDUIT(IMC)SHALL HAVE U.L.LABEL.FITTINGS SHALL BE WATERTIGHT COMPRESSION TYPE.IMC SHALL BE USED FOR LOCATIONS,CONDUIT/CABLE ROUTING,PANEL SCHEDULE,AND OTHER DETAILS WITHIN 10 DAYS OF PROJECT COMPLETION.DATE OF JOB OUTDOOR RUNS,IMC IN CONTACT WITH EARTH SHALL BE 1/2 LAPPED WRAPPED WITH HUNTS WRAP PROCESS NO.3 COMPLETION SHALL BE THE SATE ON THE CONTRACTOR'S"NOTICE OF COMPLETION"SUBMITTED TO THE OWNER,AFTER SITE INSPECTION AND 30.b. ELECTRICAL METALLIC TUBING(EMT)SHALL HAVE U.L.LABEL.FITTINGS SHALL BE GLAND RING COMPRESSION TYPE.EMT SHALL BE USED ONLY 1 03/05/2018 100%CD'S-REVISED SIGNOFF BY OWNER. FOR INTERIOR RUNS. 0 10/30/2017 100%CD'S-BP SUBMITTAL 30.c. FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L.LISTED LABEL AND MAY BE USED WHERE PERMITTED BY CODE.FITTINGS SHALL BE"JAKE"OR 15. ALL BROCHURES,OPERATING MANUAL,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE TURNED OVER TO OWNER AT JOB COMPLETION. "SQUEEZE"TYPE,LENGTH SHALL HAVE FULL SIZE GROUND WIRE. A 08/07/2017 80%CD FOR REVIEW 30.d. ALL UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40(UNLESS NOTED OTHERWISE)AT A MINIMUM DEPTH OF 24"BELOW GRADE. `REV DATE DESCRIPTION 16. ALL CIRCUIT BREAKERS,FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING NOT LESS THAN THE MAXIMUM SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED,AND A MINIMUM OF 10,000 A.I.C. 31. ALL NEW ELECTRICAL ENCLOSURES(EXCEPT FOR JUNCTION OR SPLICE BOXES)SUCH AS PANELBOARDS AND DISCONNECT SWITCHES SHALL BE e = LABELED WITH PERMANENT ENGRAVED PHENOLIC NAMEPLATES,BLACK WITH WHITE LETTERING,AND ATTACHED WITH RIVETS. 'SSS 17. PATCH,REPAIR AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. %�p�pD0 IICFNs�1�t jr% io ABBREVIATIONS ELECTRICAL LEGEND 1 ��_ �i 3527' -UGP -UGP -UGP - EXISTING U/G ELECTRICAL x x x-EXISTING CHAINLINK FENCE % • AAV ALTERNATE ACCESS VENDOR GR GROWTH(CABINET) UADU UNIVERSAL TYPE A DIGITAL UNIT 4,qi'. •• , ,� ACCA ANTENNA CABLE ASSEMBLY GRC GALVANIZED RIGID(STEEL)CONDUIT U/G UNDERGROUND `�1 !�•.• 0. 4. I'' AFF ABOVE FINISHED FLOOR IGB INTERNAL GROUND BAR WP WEATHERPROOF -OE OE OE EXISTING 0/H ELECTRICAL -x x X-NEW CHAINLINK FENCE 6, �REWAY 1 Fs ••••... •• ��+3 AWS ADVANCED WIRELESS SERVICES IMC INTERMEDIATE METALLIC CONDUIT FX MR TAFG ABOVE FINISHED GRADE IGR INTERIOR GROUND RING WW RANSFORMER FORMER 111 /0\��ENG" A/G ABOVE GROUND ISCW INSULATED STRANDED COPPER WIRE -AGP AGP AGP EXISTING A/G ELECTRICAL 0 0 0 EXISTING WOOD FENCE AGB ANTENNA GROUND BAR LTE LONG TERM EVOLUTION IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ATS AUTOMATIC TRANSFER SWITCH LTFC LIQUID TIGHT FLEXIBLE CONDUIT UGT UGT-UGT- EXISTING U/G TELEPHONE NEW WOOD FENCE ARE ACTING UNDER THE DIRECTION OF A LICENSED AWG AMERICAN WIRE GAUGE MGB MAIN(OR MASTER)GROUND BAR PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. BBU BASEBAND UNIT MMBS MULTI-MODE BASE STATION FO FO EXISTING FIBER OPTIC ` i BCW BARE COPPER WIRE MTS MANUAL TRANSFER SWITCH BSCW BARE STRANDED COPPER WIRE NEC NATIONAL ELECTRIC CODE BTCW BARE TINNED COPPER WIRE NID NETWORK INTERFACE DEVICE -HFLEX-HFLEX-HFLEX- EXISTING HYBRIFLEX CABLE DN40XC954 C CONDUIT NV NETWORK VISION 0 ELEVATION/SECTION REFERENCE.TOP 2077 NORTH FRONTAGE RD CAB CABINET 0/H OVERHEAD NUMBER IS THE DETAIL;BOTTOM CE CONCRETE ENCASED PCS PERSONAL COMMUNICATION SERVIICES -UGP -UGP -UGP - NEW U/G ELECTRIC VAIL,CO 81657 NUMBER IS THE SHEET NO. ROOFTOP CGB COLLECTOR GROUND BAR PPC POWER PROTECTION CABINET CKT CIRCUIT PRC PRIMARY RADIO CABINET -OE OE OE NEW 0/H ELECTRIC COVP CAPACITOR OVERVOLTAGE PROTECTION PVC POLYVINYL CHLORIDE DB DIRECT BURIED PWR POWER -AGP AGP-AGP- NEW A/G ELECTRIC DEI DIGITAL EXPANSION INTERFACE RGS RIGID GALVANIZED STEEL SHEET TITLE DISC DISCONNECT RRH REMOTE RADIO HEAD GENERAL ELECTRICAL EMT ELECTRICAL METALLIC TUBING RRU REMOTE RADIO UNIT -UGT UGT-UGT- NEW U/G TELEPHONE NOTES,ABBREVIATIONS, GFCI GROUND FAULT CURRENT INTERRUPTER SPD SURGE PROTECTIVE DEVICE AND ELEC. LEGEND G GROUND S/S STAINLESS STEEL FO FO NEW FIBER OPTIC GND GROUND TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR GPS GLOBAL POSITIONING SYSTEM TYP TYPICAL SHEET NUMBER -HFLEX-HFLEX HFLEX- NEW HYBRIFLEX CABLE E-1 F d•4 m 10:0 0 Spr M] 04/25/18 (E)200A METER/DISCONNECT SWITCH ! EXISTING EXISTING O MMBS CABINET BATTERY CABINET �� /^ 1.x.1,1 �.�.�, 200A/2P1 !.,_ I, TO EXISTING UTILITY (E)RECEPTACLE GENERATOR ID RECEPTACLE POWER SOURCE r (120/240V, 10,3W) Om.squared 0 �� N I JR 1387 CALLE 4 0,0. R I G I O SAN CL619)997-4012 EMENTE,CA 92673 (E)SERVICE GROUND / r (E)200A SPRINT PPC CABINET. (SEE PANEL SCHEDULE) DRAWN BY: DM 200A 200A CHECKED BY: MM 1 \ Jl / N. N' Jl J 1 0 0 o 0 0 0 ° 7---- ----- ) 100A/2P o o 0 o TO EXISTING LOADS. 7---\ (REFER TO PANEL a P oCa0 TO EXISTING LOADS. ° ° 0 0 SCHEDULE) 7---\ �� (REFER TO PANEL -< �� 7\ SUBMITTAL o C a 0 f1 03/05/2018 100%CD'S-BP SCHEDULE) ° ° 0 0 010/30/2017 100%CD'S-8P SUBMITTAL 7_\ 7---\ ' 15A/2P A 08/07/2017 90%CD FOR REVIEW 0 0 0 0 ° C 3 0 / N. DATE DESCRIPTION r O O O O 0 e a 0 100A/2P • N�/---\ � � ��� CFy�o�ps 4MAIN PANEL 0 C a 0 so . �� F1 O e a O •••4 iy ���. 3527' ! / ® SUB-PANEL 71, S :• / CIRCUIT SCHEDULE /�,,I��4 FFs'••••»• ••''��'+ NO FROM TO CONFIGURATION ����(SIO EN..= IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY O ARE ACTING UNDER THE DIRECTION OFA LICENSED UTILITY SOURCE METER/DISCONNECT EXISTING PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. O METER/DISCONNECT TRANSFER& EXISTING J LOAD CENTER O TRANSFER& GENERATOR EXISTING DN40XC954 LOAD CENTER RECEPTACLE 2077 NORTH FRONTAGE RD ® TRANSFER& O LOAD CENTER SUB-PANEL EXISTING VAIROOF OP57 NOTES: O SUB PANEL EXISTING EXISTING MMBS CABINET 1.MECHANICALLY INTERLOCKED TO PREVENT SIMULTANEOUS 1 EXISTING BATTERY CABINET EXISTING FEED FROM UTILITY AND GENERATOR,"BREAK-BEFORE-MAKE." SHEET TITLE © SUB PANEL ONE-LINE DIAGRAM SHEET NUMBER E-2 ONE-LINE DIAGRAM 1 24"x36" SCALE: NTS 11"x17" SCALE: NTS t.J Spr -1Q0D PAIN PANEL 04/25/18 SITE NUMBER: DN40XC954 ENCLOSURE TYPE: NEMA 3R BUSS RATING: 200 AMPS INTERNAL TVSS: YES VOLTAGE: 240V/120 PANEL STATUS: EXISTING NEUTRAL RATING: YES WIRE: 3 • MAIN BREAKER: 200 AMP MODEL NUMBER: TBD NEUTRAL BUS: YES AIC: 22,000 e ` MOUNT: SURFACE PHASE: 1 N to GROUND BOND: YES GROUND BAR: YES CKT CKT BKR SERV USE PHASE A PHASE B USE SERV CKT BKR CKT (71 tIci "A DESCRIPTION DESCRIPTION NO = E . AMPS P STAT LD VA FAC VA VA FAC LD VA STAT P AMPS NO 1 200 2 0 0.00 GENERATOR MAIN 0 TVSS 1.00 0 2 11.4,0 3 --- --- --- 0 0.00 — 0 1.00 0 --- --- --- 4 5 --- --- --- 0 0.00 SPACE 500 SPACE 0.00 0 --- --- --- 6 m.squared ENGINEERS 7 0 0.00 SPACE 0 LIGHT 1.00 500 ON 1 20 8 1387CALLEAVANZADO 9 100 2 ON 9150 1.25 SUB PANEL 11618 FAN 1.00 200 ON 1 10 10 SANCLEMENTE,CA92673 11 9150 1.25 11637.5 TELCO GFI 1.00 180 ON 1 20 12 (619)9974012 12118 11638 TOTAL KVA: 23.76 DRAWN BY. DM AMPS 98.98 NOTE: CL = LONG CONTINUOUS LOAD SEE SINGLE LINE DIAGRAM FOR WIRING DIAGRAM `CHECKED BY: MM• LML = LARGEST MOTOR LOAD UM = UTILITY MAIN CIRCUIT BREAKER *THIS IS A TYPICAL PANEL SCHEDULE SUBJECT GM = GENERATOR MAIN CIRCUIT BREAKER TO CHANGE AND TO BE FIELD VERIFIED. SUB—PANEL SITE NUMBER: DN40XC954 ENCLOSURE TYPE: NEMA 3R BUSS RATING: 125 AMPS INTERNAL TVSS: YES VOLTAGE: 240V/120 PANEL STATUS: EXISTING NEUTRAL RATING: YES WIRE: 31 03105/2018 100%CD'S-REVISED MAIN BREAKER: 100 AMP MODEL NUMBER: TBD NEUTRAL BUS: YES AIC: 22,000 0 0/30/2017 100%CD'S-8P SUBMITTAL MOUNT: SURFACE PHASE: 1 N to GROUND BOND: YES GROUND BAR: YES A 08/07/2017 90%CD FOR REVIEW CKT CKT BKR SERV USE PHASE A PHASE B USE SERV CKT BKR CKT REV DATE DESCRIPTION NO AMPS P STAT LD VA FAC DESCRIPTION VA VA DESCRIPTION FAC LD VA STAT P AMPS NO e 1 — SPACE 8750 SAMSUNG MMBS CABINET 1.00 0 ON 2 100 2 Ilk, 3 --- — --- SPACE 8750 1.00 0 --- --- --- 4 -.07-\p'i1PDOlIC6y�h� CS.•N......�... 44 5 --- --- --- SPACE 400 SAMSUNG BATTERY 0.00 0 ON 2 15 6 �Vrop��.A' WNq.% 1o) 7 --- --- --- SPACE 400 1.00 500 --- --- --- 8 �/ 9 --- --- --- SPACE 0 SPACE 1.00 200 --- --- --- 103527' 11 --- --- --- SPACE 0 SPACE 1.00 180 --- --- --- 1 2 // t• 9150 9150 TOTAL KVA: 18.30 ��1 s��NAL ENGr AMPS 76.25 NOTE: CL = LONG CONTINUOUS LOAD SEE SINGLE LINE DIAGRAM FOR WIRING DIAGRAM IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED LML = LARGEST MOTOR LOAD PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. UM = UTILITY MAIN CIRCUIT BREAKER *THIS IS A TYPICAL PANEL SCHEDULE SUBJECT GM = GENERATOR MAIN CIRCUIT BREAKER TO CHANGE AND TO BE FIELD VERIFIED. DN40XC954 2077 NORTH FRONTAGE RD VAIL,CO 81657 ROOFTOP SHEET TITLE PANEL SCHEDULE SHEET NUMBER E-3 PANEL SCHEDULE I 1 24"x36" SCALE: NTS 11"x17" SCALE: NTS NOTES: 1. (2)DU BREAKERS TO BE UPGRADED S FROM 16A TO 25A. MI 2. (3)RRU BREAKERS TO BE UPGRADED uv FROM 20A TO 32A. 4 6"' 3. REMAINING/UNUSED RRH BREAKERS S p r X34207-o -`- - TO BE TAGGED OUT AS"CANNOT BE USED" 1 04/25/18 - F # - • • 8 C ? - �r ' ` `•+11+l am. wI • I II II II II II II II II II �• i,-.1 !^ w L 9 1 •7W* w -(11 Al .r 1ti� i o,, _ _417 I • • • • • • • • • • • • • • • • • • m.squared ry� a •4 } I ,._; }�, '. I.j EXISTING DC BUS BAR 0 0 0O 0O DO 0O 0 0 0 DO 0 0 0 0O 0 0 0O OO ENGINEERS + rry . - al — . ma + aM NM - MI Mi - _ ' :. a • i 1387 CALLE AVANZADO ! •,?, 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O SAN CLEMENTE,CA 92673 (619)997-4012 •14..1.U•cruC 11::1:1L4V NInYDDJ • -- z z 116AI , i , 132AI 132AI , i 132AI 132A ri 132AI 132AI n i 1 _ m mu . U U I-p mu H 120A1 mu H I20AI nu ..= ill DRAWN BY: DM ii,. ,,°, F — __ — — u — — u DRACKED: MM • "' t" F1 F2 F3 F5 F6 F7 F8 9 F10 F11 F12 F13 F14 F15 F16 F17 F18 1 — -- - - - .-- - -•-- I • I (2)EXISTING 16A BREAKERS TO BE UPGRADED TO 25A BREAKERS • MI " /111 FOR NEW LTE TO DU n -• -. .e (3)EXISTING 20A BREAKERS TO BE (3)EXISTING 16A BREAKERS TO BE • a I" UPGRADED TO 32A BREAKERS FOR TAGGED OUT AS"CANNOT BE USED" II NEW 2.5GHZ RRU'S EXISTING DC POWER DISTRIBUTION 24"x36" SCALE: NTS 1 TYPICAL DC POWER DISTRIBUTION 24"x36" SCALE: NTS 11"x17" SCALE: NTS 11"x17" SCALE: NTS 2 ANTENNA MOUNTING PIPE (TYP,PER SECTOR) M N h7 NEW 2.5 ANTENNA(TYP,PER SECTOR) CC 1 03/05/2018 100%CD'S-REVISED 0 I- I- 0 10/30/2017 100%CD'S-BP SUBMITTAL LL U U W W W A 08/07/2017 90%CD FOR REVIEW #2 AWG STRANDED REV DATE DESCRIPTION NEW 2.5 RRU'S(TYP,PER SECTOR) I -- I INSULATED GND WIRE(TYP.) #6 AWG STRANDED r i INSULATED GND WIRE(TYP.) `` \ JUMPER CABLES(TYP,X9 PER SECTOR) #- .,i ....„.•••('%.ik\O0 llCeys�1�1 ••••• D 1 (N)2.5 ANTENNA ONE OR(N) NEW FIBER JUNCTION CYLINDER_v I / I `/ - -- -- -_ / • k. 1,11/14,% •• 1, c) __ L-- - -- _ i r W' N9• • MOUNTING PIPE AS NEEDED PIPE MOUNT GROUNDED TO(E) (TYP,PER SECTOR) -� � - / ••Q� � II (TYP.PER SECTOR) SECTOR GROUND BAR 1 1 " �' 1' / NEW POWER JUNCTION CYLINDER 1 Z / (TYP,PER SECTOR) -� L - -- - -- 1 3527' • ] Y I ii I �, • • W EXTERIOR FACE OF(N)OR(E) / \ BUILDING OR STRUCTURE - - -- -- -- - 1 1 7 \ . (2)EX.SPARE FIBER&DC POWER CABLES IN PE PIPES L-- -- -- -- , - �`/ / ••• ..1,+ . �i \\ TOIN CONNECTED TO NEW POWER&FIBER JUNCTION �� /Awl 111 FFn•••••N•.••• CYLINDERS(TYP,PER SECTOR) 1 1 1 U 11�8/0 \\\EN�. — EXISTING SPRINT MMES CABINETr, li, EXISTING MEDUSA BREAKOUT CYLINDER / ...-J I ILI I I (TYP,PER SECTOR) IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY Al EXISTING SPRINT ARE ACTING UNDER THE DIRECTION OF A LICENSED BATTERY CABINET PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. J / 1 DN40XC954 2077 NORTH FRONTAGE RD VAIL,CO 81657 EXISTING HYBRIFLEX CABLE ROOFTOP (TYP,PER SECTOR) g _ 1 SHEET TITLE l morn= DC DISTRIBUTION AND EXISTING GROUND BAR ANTENNA GROUNDING PLAN AND DIAGRAM SHEET NUMBER 24"x36" SCALE: NTS 24"x36" SCALE: NTS E-4 TYPICAL ANTENNA GROUNDING PLAN 11"x17" SCALE: NTS 14 TO LOW NOISE AMPLIFIER UNITS i ailit (LNA)(WHEN REQUIRED)AND TO TRANSMIT ANTENNA 02 .j 10 �., '� RECEIVE ANTENNA lid 0 t IIIIo - TYPE SS TYPE TA TYPE VB TYPE PH TYPE GR •lil �ir r r 0 16 2 �° ° ° w{J ° o �.y �y 7 j �, \ RXIIRX2 RX7/RX2 l CIO 0 ° ° 0 •oo-Q ° ° ° u �Llj /, \ 111 Illi �► ��' 110 ° 0 SEE DETAIL 1 04/25/18 �/ �_ ,`� •`. lll....... :'. COAX JUMPER REQUIRED PER lil lil MANUFACTURERS RECOMMENDATION ■ TYPE XA TYPE GT TYPE GL LUG TYPE NC TYPE PC OR FOR EASE OF CONNECTION(TYP) i i STANDARD GROUNDING KIT,TYP.(SEE NOTE t ■ • a7 ON SHEET G-2) )1I1'P.ASO Pk. �-� i "-ii LEGEND: � ' \Ili a . ANTENNA CABLE TO BTS,TYP. Irlib. 11'+;: CONNECTOR 0 1. COPPER GROUND BAR,1/4"X 4"X 20",NEWTON INSTRUMENT CO.CAT.NO.B-6142 OR EQUAL.HOLE CENTERS TO MATCH NEMA .� 1�`IIp' WEATHERPROOFING p' P DOUBLE LUG CONFIGURATION.(ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER OF GROUND CONNECTIONS) irk), i�o,, KIT,TYP. \ 6 AWG STRANDED COPPER 2. INSULATORS,NEWTON INSTRUMENT CAT.NO.3W1-4 OR EQUAL .� .� i CONDUCTOR WITH GREEN,BOON, ` _3@ TYPE PG TYPE LJ TYPE HA TYPE VS TYPE NX1 .\ 3. 5/8"LOCKWASHERS,NEWTON INSTRUMENT CO.CAT.NO.3015-8 OR EQUAL WALL MOUNTING BRACKET,NEWTON INSTRUMENT CO. `r, FROM LNA(WHEN REQUIRED) \ \ ' GROUNDING BAR,ANDREW PART# CAT NO.A-6056 OR EQUAL ID \ ' UGBKIT-0424-T(TINNED).A LOCKBOX IS ' 4. 5/8-11 X 1"HHCS BOLTS,NEWTON INSTRUMENT CO.CAT NO.3012-1 OR EQUAL YY� d d REQUIRED AT GRADE TASSCO PART# .squared , l llp':. D 351546.ANTENNA HEIGHT WILL DETERMINE ENGINEERS \ �/G NUMBER OF GROUNDING BARS AND THEIR 5. INSULATORS SHALL BE ELIMINATED WHEN BONDING DIRECTLY TO TOWER/MONOPOLE STRUCTURE.CONNECTION TO �r 2 AWG TINNED,SOLID COPPER 1011111111111111 LOCATION TOWER/MONOPOLE STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS 1387 CALLS AVANZADO CONDUCTOR EXOTHERMIC WELD TO GROUNDING BUS SAN CLEMENTE,CA 92673 TYPE RR I d_..–. _ (619)997-4012 a TYPICAL CADWELD TYPES 24"x36" SCALE, NTS 7 GROUNDING BAR CONNECTION 24x17 SCALE: NTS 4 GROUNDING BAR DETAIL 24"x36" SCALE: NTS1 11"x17" SCALE: NTS 11"x17" SCALE: NTS / 1 NOTES: EXTERNAL INSPECTION WINDOW BUTT CONDUCTORBEND DRAWN BY: DM INSULATION UP AGAINST 1. ALWAY IDIRECT GROUND WIRE GROUND D TOOTHED REQUIRED FOR ALL THE CONNECTOR BARREL ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. CHECKED BY: MM INTERIOR TWO-HOLE ANTENNA(TYP.),NUMBER OF 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS \ 1 3/8"051 1/2" CONNECTORS ANTENNAS REPRESENTED IN SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER I 1 S/S NUT �' ' 1/4" y ' THIS DETAIL ARE FOR SHOWING MIN MIN CLARITY OF GROUND SYSTEM T8B CO."C-TAP",CAT.#54730,CRIMP REQUIREMENTS ONLY. TYPE PARALLED TAP OR EQUIVALENT S/S LOCK HEAT WASHER e e SHRIN� S/S FLAT ���� ���� WASHER 1141 LABEL \—\ MIN.#6 AWG STRANDED(GREEN 1/2"COAX JUMPER JACKET)COPPER GROUND WIRE � _ HEAT SHRINK / (BONDED TO GROUND BAR,TYP.) SEE NOTE TINNED COPPER DO NOT NEW RRU PER r \ GROUNDING BAR DISCONNECT PLAN(TYP) , 1 03/05/2018 100%CD'S-REVISED HEAT SHRINK: TOWER GROUND BAR DIRECTION OF BOND TO TURN TO 0 10/30/2017 100%CD'S-BP SUBMITTAL INDOOR - CLEAR SHORTEST DISTANCE TO MGB A 08/07/2017 90%CD FOR REVIEW OUTDOOR - BLACK #2 AWG BARE COPPER `REV DATE DESCRIPTION / "DO NOT DISCONNECT" a•::"I GROUND CONDUCTOR TO #6 AWG GREEN INSULATED r �I° TAG ON ALL GROUNDING ANTENNA GROUND BAR "6; 1 1 IIBMIMill MASTER GROUND BAR STRANDED COPPER WIRE(UNIT BAR INTERCONNECTS AND BOND) -.1-161•. \\\ EQUALIZERS #2AWG GREEN STRANDED - i�p�p��PDO IICFySe'X14 CONDUCTOR S j X0.6 \ A, WN9 ; 90 24"x36" SCALE: NTS 24"x36" SCALE: NTS 24"x36" SCALE: NTS % , A. IIi. GROUND LUG TO BUS BAR8 ANTENNA GROUNDING PLAN 5 GROUI�IDING WIRE CONNECTION „"x17" SCALE: NTS 2 i 3527' : f /, 11"x17" SCALE: NTS 11'x17 SCALE: NTS NOTES: siiiiii iii 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND �, �, �, �, �, ;i #6 AWG FROM ANTENNA /41°C11:".‘ � ,il �;� CABLE GROUND KIT �`� ��� �� ,l ,�! ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND f f f,, f; 1 �� ''�...• �'� BAR. "i "i i' "i .i 2. WEATHER PROOFING SHALL BE ANDREWS. (TYPE & �1, Rows — - — (��1�s��NAL EN�=PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE6 \MANUFACTURER.) • • 11. �� di COAX GROUNDING KITS RRU TO ANTENNAS TYPICAL(6) OOR ON FLOORORON ON WALL, ANTENNA IT 15 A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY MTC 976715-15' TOWER SEE DETAIL 3 _ — ARE ACTING UNDER THE DIRECTION OF A LICENSED 1 PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. MTC 976720-20' 1II11 TOTAL OF 6 LINES PER na:1 nn n J IIit it r SECTOR IF THE SITE HAS BOTH 800 & 1900 3"FLEXIBLE CONDUIT O O O O O O O DN40XC954 1 ANTENNA CABLE K ©000 K K K O K 2077 NORTH FRONTAGE RD WEATHERPROOFING I IJ __J .__) ._J JJ K__) VAIL,CO 81657 KIT (TYP.) TO CABINET (TYP.) O ROOFTOP G11U'T I"' ill 3"SCHED.40 PVC STANDARD GROUND #6 AWG 1 --� GROUND CONDUCTOR SHALL BE ELIMINATED WHEN SHEET TITLE 1 KIT (TYP.) r� TWO HOLE LUG,OR EXOTHERMIC WELD TO BE GROUND BAR IS ELECTRICALLY BONDED TO METAL ANTENNA GROUND �� USED WITH#2 AWG BCW TO WATER TANK TOWER/MONOPOLE STRUCTURE ■ ■ WATER MAIN OR GROUND RING BAR. MOUNT z TWO HOLE LONG BARREL GROUNDING DETAILS GROUND BAR NEAR ONTRACTOR TO VERIFY THAT COMPRESSION LUGS TOP OF MONOPOLE, THE GROUND BAR IS GROUNDED El El TOWER OR ON ROOF TO THE TOWER OR RING !! ER *_GROUND BARS AT THE BOTTOM OF TOWERS/MONOPOLES SHEET NUMBER SHALL ONLY USE EXOTHERMIC WELDS. -5 E TYPICAL COAX GROUNDING 24"x36" SCALE: NTS 9 COAX GROUND KIT 24"x36" SCALE: NTS 16 WIRE TO GROUND BAR CONNECTION 24""x36"" SCALE: NTS 13 ` 11"x17" SCALE: NTS 11"x17" SCALE: NTS AP Aff4s'‘F. m ec MI Augment ID:DN40XC954Q17.1 S p r c5-1Q0D RFDS ID: 47293 04/25/18 SprintVision. RF Design Sheet 1 Site Identification Contact Information =I Location Dettli Cascade DN4DXCS61 Engineer Email Neeraj.nengspnnrmn Latitude ea3 et 4:* 9.44 v'1%;, SMS Scheduie ID 12297537 Sprint Badged RFEn Engineer Longitude -eeae . :: I SMS Schedule Name DDMauaU ode RF Engineer Email Neerelser,Btainraan Market Colorado PID 0 ++Orl4�e�a F Engineer Phone RRegion Meat ice •%. io�• Jt RRO OEM s.ar:.ag RF Manager Da}alam Rau City WI 1® switch OEM are RF Manager Email DaIe a,m.RauBRat,tDam State co RFDS Issue Date RF Manager Phone Zip Code CD/81057 1 1 W1 1.s q u a re d RFDS Revision Date W11-02-16 DO:DD.DEe Carrier Casety coda ENGINEERS RFDS Revision I 2500 LTE 2 Sector Count 1387 CALLE AVANZADO Filter Analysis Complete YES 1900 LTE 2500MHz 3 SAN CLEMENTE,CA 92673 1900 EVDO 1900MHz (619)997-4012 RFDS-Issue Date 1900 Voice 800MHz Design Status Major Natant 800 LTE Border Analysis Complete YES 800 Voice Project Description ,a.r,....am....,.....,.,",.".r / DRAWN BY: DM RF Design Sheet CH ECKED BY: MM 1 Band: 2500 Alpha Beta Gamma Delta Epsilon Zeta Ihnitiliadel Model Number RRH-B8 RRH-68 RRH-B8 N/A N/A N.A Weight MS) 59.75 59.75 5935 N/A N/A N/A Dimensions 21.26 x 15.03 x 8-03 2126 a 15,03 x 603 21_26 x 15.03 x 8.83 N/A N/A N/A Manufacturer STA STA STA N/A N/A N/A Number et RRU s needed 1 1 1 6 0 0 Mai line Coax Qy 0 0 0 0 0 0 Power Junction Cylinder Model Model Number EP96-04223A EP96-04223A EP96-04223A N/A N/A NPA 1 03/05/2018 100%CD'S-REVISED Wcight(Lbs.)4.58 4.58 4.58 NIA N/A N/A 0 10/30/2017 100%CD'S-BP SUBMITTAL Dimensions{In.) 15.35 High x 3.15 dia 15.33 High x 3.15 dia 15-35 High x 3.13 dia NPA N/A N/A A 08/07/2017 90%CD FOR REVIEW Manufacturer STA STA STA NPA N/A N/A `REV DATE DESCRIPTION Power Junction Cylinder Qty 1 1 1 0 C C r N t� IN�� Optical Junction Cylinder Qty needed 1 Model Number EP96-04225A EP96-04225A EP96-04225A N/A N/A N/A .' v tOO IIC4c, ,4, , Weight(Lbs.)404 404 4.04 N/A N/A N/A % .0.0.k• Nig.% X16 Durensio ns(In') 11 22 High x 3.15 dia 11 77 High x 3 15 dia 11.22 High x 3.15 la N/A NAR N/A t.��N�\ �y I�, Manufacturer STA STA STA NIA N/A N/A 3527' OpticaiJunetion Cylinder Qty needed �, I • • x�,o • � or 6tr •�a .•o+�•�� / II0'h�''uNAL EY'� ` N.prtr.wuiiIan RF Design Sheet ��"��� IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED Band:• ='O Alpha Beta Gamma Delta Epsilon Zeta PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. Antennal ilk 111111111 _ Madel Number HPA85 R-KE4AA-K HPAS5R-KE4AA-K HPAS5R-KE4AA-K Weight(Ins)287 28-7 28.7 N/A N/A NIA Dimensions 48 x11.7 x 7.6 48 x 11 7x7.6 48 x 117 x 7_5 NIA NIA NIA DN40XC954 Manufacturer CCI CCI CGI N/A N/A N/A 2077 NORTH FRONTAGE RD NEl1 Top Jumper Make/Mode/MI 25 Ju 4 2.5 Jumper a 25Jum Jumper4 N/A 0 NIA 0 NIA 0 . VAIL,OF 081657 f°� I � � p I � � � ROOFTOP Ant 1 RF requested Diameter 1/2" 1/2' 1/2' N/A N/A NfA Ant 1 RF requested Top Jumper NTA N/A WA N/A NIA N/A Length/n) Antenna 1 Azimuth 40 340 230 N/A NJA WA r SHEET TITLE Antenna 1 Mechanical DT 0 0 0 N/A N/A WA RADIO FREQUENCY Antenna 1 Center Line(R) 34 6 39.8 04 4 WA N/A N/A DATA SHEET SHEET NUMBER RADIO FREQUENCY DATA SHEET 24"x36" SCALE: NTS 1 RF-1 11"x17" SCALE: NTS AS OF if, 40. NOTE: (E)SPRINT 800/1900MHz DUAL BAND TOP OF EXISTING STEALTH TUBE e +0 1. ALL NEW ANTENNAS WILL BE PAINTED TO MATCH ANTENNA MOUNTED INSIDE STEALTH TUBE / ELEV.±43'-4"AGL {.dOr VL THE BUILDING TO BE REMOVED AND REPLACED;(1)TOTAL M TOP OF EXISTING SPRINT PANEL ANTENNAS gig ELEV.±41'-7"AGL RTI _ _ RAD CENTER OF EXISTING SPRINT PANEL ANTENNASUV ELEV.±39'-7"AGL TOP OF EXISTING BUILDING l^ VIELEV.±36'-10"AGLS7 TOP OF EXISTING SPRINT PANEL±NTENNAS #Q0^� 11 ELEV.ANTE"AGL RAD CENTER OF EXISTING SPRINT PANEL ANTENNAS Ii ELEV.34'-5"AGL 04/25/18 (E)SPRINT 800/1900MHz DUAL BAND ANTENNA /1/_ MOUNTED ON(E)PIPE TO BE REMOVED AND REPLACED;(2)TOTAL N (E)ANTENNAS BY OTHERS 1 (E)ROOFTOP LADDER ACCESS Cal t2 EXISTING EQUIPMENT PLATFORM LEVEL ':.:±.”.-5 �ti A ELEV.24'-0"AGL 1`r/ m.squared ENGINEERS 1387 CALLE AVANZADO SAN CLEMENTE,CA 92673 (619)997-4012 -• i ' )E)SPRINT EQUIPMENT ROOM ACCESS DOOR / DRAWN BY: DM f./ / (E)SPRINT METER SOCKET .4.--.-_,,,, // CHECKED BY: MM (E)SPRINT DISCONNECT SWITCH \ �(�� TD'- (E)SPRINT GEN.PLUG / 1 GROUND LEVEL ELEV.0'-0"AGL EXISTING SOUTHEAST ELEVATION 24"x36" SCALE: 3/16" = 1,-0" 2' 4' 8' 11"x17" SCALE: 3/32" = 1'-0" ® 1 NOTE (N)SPRINT TRI-BAND PANEL ANTENNA TOP OF EXISTING STEALTH TUBE 1. ALL NEW ANTENNAS WILL BE PAINTED TO MATCH MOUNTED ON(N)PIPE INSIDE(E) / ELEV.±43'-4"AGL THE BUILDING ��� STEALTH TUBE;(1)TOTAL 1 03/05/2018 100%CD'S-REVISED TOP OF NEW SPRINT PANEL ANTENNAS * ELEV.±41'-7"AGL 0 10/30/2017 100%CD'S-BP SUBMITTAL _RAD CENTER OF NEW SPRINT PANEL ANTENNAS A 08/07/2017 90%CD FOR REVIEW - — ELEV.±39'-7"AGL `REV DATE DESCRIPTION TOP OF EXISTING BUILDING ELEV.±36'-10"AGL TOP OF NEW SPRINT PANEL ANTENNAS r 1 IN O _ _ _RAD CENTER OF NEW SPRINT PANEL ELEV.34'SNAGLL� p�pDO IICF\‘‘ 1 ©�©© (N)SPRINT TRI-BANDPANEL ANTENNA .0",\\.T`" ^' rY/7A~••• ,I .•Q� / I ��m � TO BE MOUNTED ON(N)PIPE;(2)TOTAL (E)ANTENNAS BY OTHERS % ? �' ,� • (E)ROOFTOP LADDER ACCESS i 3527 EXISTING EQUIPMENT PLATFORM LEVEL A11004,'.b f ELEV.24,0"AGL 11��•... �.����. i 1111 IUNAL EN\__ IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY / \ ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. I DN40XC954 2077 NORTH FRONTAGE RD VAIL,CO 81657 (E)SPRINT EQUIPMENT ROOM ACCESS DOOR ROOFTOP (E)SPRINT METER SOCKET II,,��II (E)SPRINT DISCONNECT SWITCH T3I (E)SPRINT GEN.PLUG r SHEET TITLE GROUND LEVEL$ ELEVATIONS ELEV.0'-0"AGL SHEET NUMBER NEW SOUTHEAST ELEVATION 24"x36" SCALE: 3/16" = 1'-0" 0" 2' 4' 8' A-4 11"x17" SCALE: 3/32" = 1'-0" fI SAMSUNG 2.5 GHz RRH 8.03" MANUFACTURER: SAMSUNG / {J DIMENSIONS, HxWxD: 21.26'x15.03"x8.03" M. EXISTING PNLGANANTENNA VA NEW 2"0 STD.STEEL PIPE;TYP.OF 3. WEIGHT: 59.75Ibs. i ( _-_ 1 L ` MI PROVIDE UNISTRUT P1117 PIPE WEIGHT W/ BRACKET: 71.8 LBS. r—� Jam""'"^" "'"""�L CLAMP AT EACH INTERSECTION WITH t °°°°°°° °° 44 UNISTRUT P1000 qq�� / I1} I (E)WALL 15.03" III S r Y�y `'1:2i1 • it 000co0o0o0o0o0o0o0oco0,0o =,, e ' o 111-1=0-101111 I�I� r 04125118 0 0 0 0 0 0 0 0 0000..0 NEW 3 POINT °°° °°° 3"-4 1/2"ANTENNA PIPE MAST MOUNTING AND UNISTRUT P1000; It ra t- le(:)()� ❑ °° °° PER PLAN DOWNTILT BRACKETTYP.OF2 ' I ° ° / 011o ooO000 II .■ ■. € 000S o°° oo iI NEW RRU UNIT W/TYP. ` ` I O�I _ ■ = 1 ixrixrixd A.`i: 'ki F `.� ..., �. MFG.PIPE MOUNTING O \_7 BRACKET;TYP.OF 3 �_ : 1 00 r /�\ /� 11\ BOTTOM VIEW SIDE VIEW FRONT VIEW G- c #6 AWG RRU / / (8) RF OUTPUT ( 1, rj, GROUND 1/4"HILTI KWIK-CON 110-ANCHOR / PORTS W1 ROD WITH HILTI HIT-HY200 NOTES: �❑O° ❑O° Ivry} RF CALIBRATION I ■■■.squared 1141 ADHESIVE(ICC-ESR3187) COMPLY WITH MANUFACTURES o nV(`-"4'IL,J `t (4 PER UNISTRUT; INSTRUCTIONS TO ENSURE THAT ALL \ • PORT l`0'' IU ENGINEERS EQUALLY SPACED) RRH'S RECEIVE ELECTRICAL POWER L,❑7 o DC POWER GROUND BAR #2 AWG MOUNT STRUT GROUND WITHIN 24 HOURS OF BEING REMOVED / ° CONNECTOR . 1387 CALLE AVANZADO FROM THE MANUFACTURER'S AMPHENOL FIBER RET CONNECTOR SAN CLEMENTE,CA 92673 PACKAGING. DO NOT OPEN RRH MPO CONNECTORLED INDICATOR (619)997-4012 PACKAGES IN THE RAIN. PORT LAYOUT PLAN EQUIPMENT WALL MOUNT 24""x36" SCALE N15 6 (N) 2.5 GHZ RRU 24"x36" SCALE: NTS 3 (N) AND (E) ANTENNA MOUNTING 11 x;7 SCALE NTS 1 ; ' 11"x17" SCALE: NTS MANUFACTURER: CCI MECHANICAL ' C H LI C ALU EQUIPMENT CABINET NOTE: DRAWN BY: DM • MODEL NO.: HPA65R-KE4AA-K LOCATIONS SHOWN FOR INSTALLATION OF NEW pEQUIPMENT IN EXISTING CABINET ARE MODULARITY QUAD DIMENSIONS: CONNECTOR TYPE: TOTAL MIN. CABINET CLEARANCE APPROXIMATE. ACTUAL SPACE AVAILABLE TO BE CHECKED BY: MM C A 48" (6) 7/16" DIN (FEMALE)WEIGHT : VERIFIED IN FIELD ON A SITE BY SITE BASIS. WEIGHT W/ BRACKETS 14.4 LBS (6.6KG) N / .N m B 11.7" CONNECTOR LOCATION: RF CABINET 6.26X7.42X8.17 in. - 28.7 LBS (159X168.5X207.4mm) C 7.6 BOTTOM - FRONT- 72" - REAR- 72" ELECTRICAL \O 0 0 O — LEFT- 37.8" RF PARAMETERS PORTS FREQUENCY(MHz) SPECIFICATION FRONT VIEW ESTIMATED WEIGHT: 1,074 LBS. I RETURN LOSS COMMON 1695 - 2180 18 dB min, 20 dB typ _A_ -A- _A_ _A_ PCS/AWS 1695 - 2180 18 dB min, 20 dB typ - - - - - - ,J B BRS 2496 - 2690 18 dB min, 20 dB typ INSERTION LOSS COMMON TO PCS/AWS 1695 - 2180 0.2 dB typ, 0.25dBmax COMMON TO BRS 2496 - 2690 0.2 dB typ, 0.25dBmax REJECTION COMMON TO PCS/AWS 2496 - 2690 50 dB mini COMMON TO BRS 1695 - 2180 50 dB mini _= _—_ _�_' _�_'L) ISOLATION PCS/AWS TO BRS 1695 - 2180 50 dB mini r r Y Y II BRS TO PCS/AWS 2496 - 2690 50 dB mini 0 09/05/2017 100%CD'S-BP SUBMITTAL SIDE VIEW 35.4" % A 08/07/2017 90%CD FOR REVIEW GENERAL CHARACTERISTICS 742„ _ `REV DATE DESCRIPTION •General Impedance 50 ohms r / Cont.Average PWR 250 W max p ports), (Commonport) r` rt r' '' e \ g (input orts, 500 W maximum ort /'® o o .I _ / Peak Envelope PWR 1 kW max (input ports), 3 kW maximum (Common port) .,•��cV3y► 0 0 0 'A.,.1���� / ......0.. xvoo Intermodulation <-117 dBm (-160 dBc) at 2 x+43 dBm tones all bands ® I® �`�® cc O\p�pDO IICF�/O\1111 TOP VIEW u TOP VIEW FRONT VIEW SIDE VIEW •. ?' ip V-1!:� �i �0.............. 1, i •. pt). Nq. •. 1O 24"x36" SCALE: NTS 24"x36" SCALE: NTS L____ L_J / ••�' �� ,� (N) QUADPLEXER DPO-7126Y-0X1 7 (N) TRI-BAND PANEL ANTENNA o 00 00 00 0O • 11'x17' SCALE: NTS 11"x17" SCALE: NTS u I 3527' .41 N Af,t • ,r:�ilk 41W. :i•: oi. , t 6. ....... .. TOP VIEW ❑00❑ 111 `,0NAL ,,,,, .......................................: 00 00 00 00 INSTALL NEW 2.5 EQUIPMENT — IN EXISTING MMBS CABINET e rNrvrnl e e OIO2I01 e INCLUDING BUT NOT LIMITED DC LUGS DC LUGS IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY TO BASE BAND UNIT, CELL • . - , ARE ACTING UNDER THE DIRECTION OF A LICENSED SITE ROUTER AND SURGE II®® CIE EnnEl E0®n nEl PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. ARRESTORS. POWER & FIBER . I TO BE CONNECTED 0 _ jr 0 0 0 0 0 0 0 \ GFCI 00000 00 0 0 0 0 0 0 0_ CONCRETE PAD ` s 0000 1 o DN40XC954 0 0 0 0 0 0 \ 0v0 55 ~� 2077 NORTH FRONTAGE RD 0 0 0 0 0 o FRONT VIEW \ S'°` S'°` VAIL,CO 81657 ''CD(-) " NEW (4) STRINGS OF ROOFTOP 0 0 0 0 0 0 0BATTERIES TO BE INSTALLED IN EXISTING BATTERY ' o 0 0 0 0 0 o BACKUP UNIT CABINET 9928 CABINET SHEET TITLE / \ EQUIPMENT DETAILS BOTTOM PLAN FRONT ELEVATION SHEET NUMBER NOT USED 24"x36" SCALE: NTS 11"x17" SCALE: NTS g (E) BATTERY BACKUP UNIT CABINET 4"x36" SCALE: NTS I 11"x17" SCALE: NTS 5 (E) MMBS CABINET 24"x36" SCALE: NTS I 2 , D-1 11"x17" SCALE: NTS GENERAL ELECTRICAL NOTES e 414 � r IliVIe 1. SUBMITTAL OF BIO INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PREFORMED UNDER THIS CONTRACT. 513 4:1111.4.11' 18. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING PURPOSED THORUGH THE FLOOR OR WALLS FOR CONDUIT RUNS, 2. CONTRACTOR SHALL THE ACTUAL CONSTRUCTION.CCONTRACTOR SHALL FORM ALL FIELD A ISSUEWRITTEN NOTICE OF ALLN AND EXAMINATION WORK RIOR TO FINDINGS HE TO THE ENGINEER AND OWNER LISTING ALDERING OF THE ELECTRICAL L AND PIPE RUNS,ETC.,IT ANY CIRCUMSTANCES.UST CLEARLY UNDERSTOOD THAT TENDONS AND/OR REINFORCING STEEL WILL NOT BE DRILLED INTO,CUT,OR DAMAGED UNDER r 'QOJ�015 MALFUNCTIONS,FAULTY,EQUIPMENT,AND DISCREPANCIES. 19. EXACT LOCATION OF TENDONS AND/OR REINFORCING STEEL ARE NOT KNOWN AND THEREFORE MUST BE SEARCHED FOR BY APPROPRIATE 04/25/18 3. THESE PLANS ARE SCHEMATIC ONLY;CONTRACTOR SHALL FOLLOW AS CLOSELY AS POSSIBLE. METHODS,SUCH AS X-RAY EQUIPMENT OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING AND/OR STEEL TENDONS. 4. ANTENNA MOUNTING HEIGHTS AND AZIMUTHS SHALL BE VERIFIED WITH OWNER PRIOR TO INSTALLATION. 20. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WITH SUITABLE WEATHERPROOF SEALANT.PENETRATIONS IN FIRE RATED WALLS SHALL • BE FIRE STOPPED IN ACCORDANCE WITH CURRENT LOCAL BUILDING CODES USING U.L.RATED MATERIALS. 1 5. CONTRACTOR SHALL PROVIDE ALL LABOR,MATERIALS,INSURANCE,EQUIPMENT,INSTALLATION,CONSTRUCTION TOOLS,TRANSPORTATION,ETC., FOR A COMPLETE AND PROPERLY OPERATIVE SYSTEM ENERGIZED THROUGHOUT AND AS INDICATED ON DRAWINGS,AS SPECIFIED HEREIN AND/OR 21. ALL CONDUCTORS SHALL BE COPPER,#12 AWG MINIMUM.UNLESS NOTED OTHERWISE,INSULATION SHALL BE 90°C RATED,AND DUAL RATED AS OTHERWISE INDICATED.NOTE THAT CONTRACTOR SHALL SECURE ALL NECESSARY ELECTRICAL PERMITS,AND PAY ALL REQUIRED FEES. THHN/THWN-2.NO BX OR ROMEX CABLE IS PERMITTED UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS. ,. .. Cal CA Cal 1.M 6. IF REQUIRED,CONTRACTOR SHALL COORDINATE WITH LOCAL UTILITY COMPANY FOR CONNECTION OF TEMPORARY AND PERMANENT POWER TO 22. ALL CONDUIT ONLY(C.O.)RUNS SHALL HAVE A PULL WIRE OR ROPE,AND TRUE TAPE. THE SITE.THE TEMPORARY POWER AND ALL HOOK-UP COSTS SHALL BE PAID BY THE CONTRACTOR. - k4, 23. GROUND THE ENTIRE ELECTRICAL SYSTEM IN ACCORDANCE WITH THE NEC AND DRAWINGS.BELOW GRADE GROUND CONDUCTORS SHALL BE#2 )vii, ; )� 7. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AND SHALL BE OF THE BEST GRADE AND OF THE AWG SOLID BARE TINTED COPPER.ABOVE GRADE,ALL CONDUCTORS SHALL BE STRANDED GREEN INSULATED COOPER,SEIZED#2 AWG OR AS SHOWN SAME MANUFACTURER THROUGHOUT FOR EACH CLASS OR GROUP OF EQUIPMENT.EXCEPTIONS TO THIS MAY BE PERMITTED IF NEW IN THE DRAWINGS.GROUND CONDUCTOR SHALL HAVE A MINIMUM 24"BENDING RADIUS.GROUND RODS SHALL BE COPPER CLAD STEEL,5/8"ROUND m.sq uared REPLACEMENT BREAKERS OR SWITCHES ARE NOT AVAILABLE FOR ORIGINAL ELECTRICAL DISTRIBUTION EQUIPMENT--ON THAT CASE. AND 8'LONG.GROUNDING HARDWARE SHALL BE ERICO,STORM COPPER COMPONENTS,FUSHI COPPERWELD OR APPROVED EQUAL. ENGINEERS RECONDITIONED EQUIPMENT MAY BE PERMISSIBLE IF IT CARRIES ONE(1)YEAR WARRANTY.MATERIALS SHALL BE LISTED AND APPROVED BY UNDERWRITER'S LABORATORY AND SHALL BEAR THE INSPECTION LABEL"J"WHERE SUBJECT TO SUCK APPROVAL.MATERIALS SHALL MEET WITH 24. GROUND ALL ANTENNA BASES,ENCLOSURES,FRAMES,CABLE RUNS,AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT 1387 CALLE AVANZADO APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL GOVERNING BODIES HAVING JURISDICTION.MATERIALS SHALL BE MANUFACTURED IN TO THE BUS BARS.FOLLOW EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR GROUNDING.GROUND COAX SHIELD AT BOTH ENDS USING CABLE SAN CLEMENTE,CA 92673 ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY ANSI,NEMA,AND NBFU. MANUFACTURER'S RECOMMENDATIONS. (619)997-4012 8. IF CONTRACTOR IS PROPOSING ALTERNATE MATERIALS OR CONSTRUCTION METHODS FROM WHAT IS SPECIFIED IN THE PLANS,CONTRACTOR 25. THE NUMBER OF GROUNDING BARS MAY VARY DEPENDING UPON THE SITE LAYOUT,ANTENNA LOCATION,AND OTHER FACTORS.THE s., -• SHALL SUBMIT SHOP DRAWINGS AND/OR CATALOG CUT-SHEETS TO OWNER FOR APPROVAL PRIOR TO COMMENCEMENT OF THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SUFFICIENT GROUNDING BARS AS REQUIRED,PROVIDING 50%SPARE CONNECTION POINTS. 9. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL CODES AND ALL LOCAL AND STATE CODES,LAWS,AND 26. EXOTHERMIC WELDS SHALL INCLUDE ALL CABLE TO CABLE,SPLICES,CABLE TO GROUND RODS,GROUND ROD SPLICES AND OTHER SYSTEMS AS ORDINANCES.PROVIDE ALL COMPONENTS AND WIRING SIZES AS REQUIRED TO MEET NEC. INDICATED.ALL MATERIALS USED(MOLDS,WELDING,METAL,ETC.)SHALL BE INSTALLED PER MANUFACTURERS'RECOMMENDATIONS AND DRAWN BY: PROCEDURES.ALL EXOTHERMIC WELD CONNECTIONS ON GALVANIZED SURFACES SHALL BE CLEANED THOROUGHLY AND COLORED TO MATCH 10. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN EACH PANELBOARD,PULLBOX,J-BOX,SWITCH BOX,ETC.,IN SURFACE WITH(2)TWO COATS OF GALVITE(WHITE)PAINT OR SILVERBRITE(ALUMINUM). ,.CHECKED BV: MM COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION(O.S.H.A.)REQUIREMENTS. 27. ALL STRANDED COPPER WITH GREEN INSULATION TO BE ATTACHED WITH CRIMPED DOUBLE LUG,ATTACHED WITH NUTS,BOLTS AND STAR 11. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE(1)YEAR AFTER THE DATE OF JOB ACCEPTANCE BY OWNER,ANY WORK,MATERIAL WASHERS TYPICAL.ALL MECHANICAL CONNECTIONS SHALL HAVE ANTI-OXIDANT GREASE(E.G.NO-OX)APPLIED BETWEEN LUG AND BUS BAR. OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE,UPON WRITTEN NOTIFICATION,AT THE EXPENSE OF THE CONTRACTOR. 28. ALL EXPOSED TINNED COPPER GROUNDS SHALL BE PROTECTED BY 1/2"PVC CONDUIT AND SECURED.WHERE SUBJECT TO MECHANICAL DAMAGE, OTHER GROUND LEADS SHALL ALSO BE ENCLOSED IN 1/2"OR 3/4"LTFC. 12. CLEAN WORK SITE DAILY,AND REMOVE ALL DEBRIS RESULTING FROM CONSTRUCTION.LEAVE JOB SITE IN A TIDY AND UNDAMAGED CONDITION. 29. COMPRESSION FITNESS TO BE USED ON ALL CONDUITS(NO SETSCREWS). 13. UPON COMPLETION OF WORK,PERFORM CONTINUITY,SHORT CIRCUIT,AND GROUNDING TEST.GROUNDING SYSTEM SHALL BE TESTED BY INDEPENDENT TESTING AGENCY,WITH WRITTEN REPORT SUBMITTED TO THE OWNER FOR REVIEW AND APPROVAL.AFTER APPROVAL,FURNISH 30. PVC CONDUIT INSTALLED IN OUTDOOR LOCATIONS SUBJECT TO SUNLIGHT EXPOSURE SHALL BE UV RESISTANT.SURFACE-MOUNTED CONDUIT ONE COPY OF REPORT TO ENGINEER. INSTALLED IN LOCATIONS SUBJECT TO FOOT TRAFFIC OR OTHER WEAR AND TEAR,SHALL BE PVC SCHEDULE 80,IMC,OR GRC. CONDUIT RUNS ALONG WALLS OR FLOORS SHALL BE SURFACE MOUNTED UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS.OTHER CONDUIT REQUIREMENTS: 14. PROVIDE OWNER WITH ONE SET OF COMPLETE ELECTRICAL"AS BUILT"DRAWINGS AT THE COMPLETION OF THE JOB,SHOWING ACTUAL EQUIPMENT 30.a. INTERMEDIATE METALLIC CONDUIT(IMC)SHALL HAVE U.L.LABEL.FITTINGS SHALL BE WATERTIGHT COMPRESSION TYPE.IMC SHALL BE USED FOR LOCATIONS,CONDUIT/CABLE ROUTING,PANEL SCHEDULE,AND OTHER DETAILS WITHIN 10 DAYS OF PROJECT COMPLETION.DATE OF JOB OUTDOOR RUNS,IMC IN CONTACT WITH EARTH SHALL BE 1/2 LAPPED WRAPPED WITH HUNTS WRAP PROCESS NO.3 COMPLETION SHALL BE THE SATE ON THE CONTRACTOR'S"NOTICE OF COMPLETION"SUBMITTED TO THE OWNER,AFTER SITE INSPECTION AND 30.b. ELECTRICAL METALLIC TUBING(EMT)SHALL HAVE U.L.LABEL.FITTINGS SHALL BE GLAND RING COMPRESSION TYPE.EMT SHALL BE USED ONLY SIGNOFF BY OWNER. FOR INTERIOR RUNS. 0 09/05/2017 100%CD'S-BP SUBMITTAL 30.c. FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L.LISTED LABEL AND MAY BE USED WHERE PERMITTED BY CODE.FITTINGS SHALL BE"JAKE"OR 15. ALL BROCHURES,OPERATING MANUAL,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE TURNED OVER TO OWNER AT JOB COMPLETION. "SQUEEZE"TYPE,LENGTH SHALL HAVE FULL SIZE GROUND WIRE. A 08/07/2017 90%CD FOR REVIEW 30.d. ALL UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40(UNLESS NOTED OTHERWISE)AT A MINIMUM DEPTH OF 24"BELOW GRADE. `REV DATE DESCRIPTION 16. ALL CIRCUIT BREAKERS,FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING NOT LESS THAN THE MAXIMUM SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED,AND A MINIMUM OF 10,000 A.I.C. 31. ALL NEW ELECTRICAL ENCLOSURES(EXCEPT FOR JUNCTION OR SPLICE BOXES)SUCH AS PANELBOARDS AND DISCONNECT SWITCHES SHALL BE e = LABELED WITH PERMANENT ENGRAVED PHENOLIC NAMEPLATES,BLACK WITH WHITE LETTERING,AND ATTACHED WITH RIVETS. 'SSS 17. PATCH,REPAIR AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. %�p�pD0 IICFNs�1�t jr% io ABBREVIATIONS ELECTRICAL LEGEND 1 ��_ �i 3527' -UGP -UGP -UGP - EXISTING U/G ELECTRICAL x x x-EXISTING CHAINLINK FENCE % • AAV ALTERNATE ACCESS VENDOR GR GROWTH(CABINET) UADU UNIVERSAL TYPE A DIGITAL UNIT 4,qi'. •• , ,� ACCA ANTENNA CABLE ASSEMBLY GRC GALVANIZED RIGID(STEEL)CONDUIT U/G UNDERGROUND `�1 !�•.• 0. 4. I'' AFF ABOVE FINISHED FLOOR IGB INTERNAL GROUND BAR WP WEATHERPROOF -OE OE OE EXISTING 0/H ELECTRICAL -x x X-NEW CHAINLINK FENCE 6, �REWAY 1 Fs ••••... •• ��+3 AWS ADVANCED WIRELESS SERVICES IMC INTERMEDIATE METALLIC CONDUIT FX MR TAFG ABOVE FINISHED GRADE IGR INTERIOR GROUND RING WW RANSFORMER FORMER 111 /0\��ENG" A/G ABOVE GROUND ISCW INSULATED STRANDED COPPER WIRE -AGP AGP AGP EXISTING A/G ELECTRICAL 0 0 0 EXISTING WOOD FENCE AGB ANTENNA GROUND BAR LTE LONG TERM EVOLUTION IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ATS AUTOMATIC TRANSFER SWITCH LTFC LIQUID TIGHT FLEXIBLE CONDUIT UGT UGT-UGT- EXISTING U/G TELEPHONE NEW WOOD FENCE ARE ACTING UNDER THE DIRECTION OF A LICENSED AWG AMERICAN WIRE GAUGE MGB MAIN(OR MASTER)GROUND BAR PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. BBU BASEBAND UNIT MMBS MULTI-MODE BASE STATION FO FO EXISTING FIBER OPTIC ` i BCW BARE COPPER WIRE MTS MANUAL TRANSFER SWITCH BSCW BARE STRANDED COPPER WIRE NEC NATIONAL ELECTRIC CODE BTCW BARE TINNED COPPER WIRE NID NETWORK INTERFACE DEVICE -HFLEX-HFLEX-HFLEX- EXISTING HYBRIFLEX CABLE DN40XC954 C CONDUIT NV NETWORK VISION 0 ELEVATION/SECTION REFERENCE.TOP 2077 NORTH FRONTAGE RD CAB CABINET 0/H OVERHEAD NUMBER IS THE DETAIL;BOTTOM CE CONCRETE ENCASED PCS PERSONAL COMMUNICATION SERVIICES -UGP -UGP -UGP - NEW U/G ELECTRIC VAIL,CO 81657 NUMBER IS THE SHEET NO. ROOFTOP CGB COLLECTOR GROUND BAR PPC POWER PROTECTION CABINET CKT CIRCUIT PRC PRIMARY RADIO CABINET -OE OE OE NEW 0/H ELECTRIC COVP CAPACITOR OVERVOLTAGE PROTECTION PVC POLYVINYL CHLORIDE DB DIRECT BURIED PWR POWER -AGP AGP-AGP- NEW A/G ELECTRIC DEI DIGITAL EXPANSION INTERFACE RGS RIGID GALVANIZED STEEL SHEET TITLE DISC DISCONNECT RRH REMOTE RADIO HEAD GENERAL ELECTRICAL EMT ELECTRICAL METALLIC TUBING RRU REMOTE RADIO UNIT -UGT UGT-UGT- NEW U/G TELEPHONE NOTES,ABBREVIATIONS, GFCI GROUND FAULT CURRENT INTERRUPTER SPD SURGE PROTECTIVE DEVICE AND ELEC. LEGEND G GROUND S/S STAINLESS STEEL FO FO NEW FIBER OPTIC GND GROUND TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR GPS GLOBAL POSITIONING SYSTEM TYP TYPICAL SHEET NUMBER -HFLEX-HFLEX HFLEX- NEW HYBRIFLEX CABLE E-1 F d•4 m 0 0:0 Spr -1010D 04/25/18 • / (E)200A METER/DISCONNECT SWITCH /// EXISTING EXISTING O MMBS CABINET BATTERY CABINET / � 200A/2P (E)200A GENERATOR '' r.'sr,-. TO EXISTING UTILITY 0 o o f RECEPTACLE •L ` j�� POWER SOURCE �/ (120/240V, 10,3W) O m.squared 0 �� N I E8VGINEER./ 1387 CALLE O K_ I G I / O - - SAN C(619)997-4012 EMENTE,CA 92673 \ i (E)SERVICE GROUND / r (E)200A SPRINT PPC CABINET. (SEE PANEL SCHEDULE) DRAWN BY: DM 200A 200A CHECKED BY: MM O J J 1 �\ �- 0 0 o o 0 0 0 �� 100A/2P o o o o TO EXISTING LOADS. 7---\ (REFER TO PANEL e " a 100A 2P o TO EXISTING LOADS. 0 0 0 0 SCHEDULE) ,-\ 7--\ f (REFER TO PANEL 7---\ 7\ 0 e a 0 0 09/05/2017 100%CD'S-BP SUBMITTAL SCHEDULE) 0 0 0 0 7 \ 7--\ 7---\ �-\ 15A/2P A 08/07/2017 90%CD FOR REVIEW 0 0 0 0 O e a O / `REV DATE DESCRIPTION 0 0 0 0 o e a o 100A/2P ---\ 77 �� Nkv, MAIN PANEL o e a 0 i%o\p�PDO..............�11 0 0 1 •'�s1,* W yq 4:%'' y �)(�l ity 3527' / ® SUB-PANEL S• i CIRCUIT SCHEDULE .0.--- \\‘‘... / ��'O�F''• ..••<4'� NO FROM TO CONFIGURATION 1111��/����ENG\ IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY O UTILITY SOURCE METER/DISCONNECT EXISTINGARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. O METER/DISCONNECT TRANSFER& EXISTING ,. ' LOAD CENTER O TRANSFER& GENERATOR EXISTING DN40XC954 LOAD CENTER RECEPTACLE 2077 NORTH FRONTAGE RD ® TRANSFER& LOAD CENTER SUB-PANEL EXISTING VAIL,CO OP57 NOTES: O SUB PANEL EXISTING MMBS CABINET EXISTING 1.MECHANICALLY INTERLOCKED TO PREVENT SIMULTANEOUS r © SUB PANEL EXISTING BATTERY CABINET EXISTING FEED FROM UTILITY AND GENERATOR,"BREAK-BEFORE-MAKE." SHEET TITLE ONE-LINE DIAGRAM SHEET NUMBER ONE-LINE DIAGRAM 24"x36" SCALE: NTS 1 E-2 11"x17" SCALE: NTS NOTES: lo 1. (2)DU BREAKERS TO BE UPGRADED S FROM 16A TO 25A. MI 2. (3)RRU BREAKERS TO BE UPGRADED ,siti OF iv, FROM 20A TO 32A. 41' 3. REMAINING/UNUSED RRH BREAKERS S p r ��� �' �� • TO BE TAGGED OUT AS"CANNOT BE USED" 04/25/18 F 1 . 14020 YII • �I� ' IL I I 1111 :;, irr abgrilliet : I m.squared '',' " r raj .3 _,• j EXISTING DC BUS BAR 7OO 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ENGINEERS 1387 CALLE AVANZADO SAN CLEMENTE,CA 92673 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Y y � y cui�f�°.;4s !. -•• _ } (619)9974012 '•i,ii.L.WLMI uD14U1-...au., ""-, , / / No. / Z z 11 6A1 I16AI , I32AI I32AI , I32AI I32AI I32AI I32AI + m m U Im — — U E'er AI — U I20AI I AI U — I20AI 1 1A .. * `J `J DRAWN BY: DM Ilt . #i+ 0. -ry ,y . o / / CHECKED BY: MM :� IA 1111 "'W *X` F1 F2 F3 F4 F5 F6 F7 F8 9 F10 F11 F12 F13 F14 F15 F16 F17 F18N. _ — — MPR (2)EXISTING 16A BREAKERS TO BE UPGRADED TO 25A BREAKERS r ► t t • FOR NEW LTE TO DU 4 -° -# •p •e (3)EXISTING 20A BREAKERS TO BE (3)EXISTING 16A BREAKERS TO BE .r ,r, .r UPGRADED TO 32A BREAKERS FOR TAGGED OUT AS"CANNOT BE USED" - -- ■ NEW 2.5GHZ RRU'S EXISTING DC POWER DISTRIBUTION 24"x36" SCALE: NTS 11"x17" SCALE: NTS 1 TYPICAL DC POWER DISTRIBUTION 24"x36" SCALE: NTS 11"x17" SCALE: NTS 2 ANTENNA MOUNTING PIPE (TYP,PER SECTOR) • N I ) NEW 2.5 ANTENNA(TYP,PER SECTOR) 0 0 0 I- I- I- 0 09/05/2017 100%CD'S-BP SUBMITTAL U U U W CD CD A 08/07/2017 90%CD FOR REVIEW #2 AWG STRANDED REV DATE DESCRIPTION NEW 2.5 RRU'S(TYP,PER SECTOR) INSULATED GND WIRE(TYP.) #6 AWG STRANDED e I INSULATED GND WIRE(TYP.)1 -1 ...1.4.�5� \ JUMPER CABLES(TYP,X9 PER SECTOR) I .4.11% OO IICFys1�II - % ••• I NEW FIBER JUNCTION CYLINDER \� I / I / L _ _ _ •0..... .........��p• Wyq • 46 (N)2.5 ANTENNA ON(E)OR(N) �� MOUNTING PIPE AS NEEDED PIPE MOUNT GROUNDED TO(E) (TYP,PER SECTOR) - • " (TYP.PER SECTOR) SECTOR GROUND BAR NEW POWER JUNCTION CYLINDER 77 0 i �O '� 5 (TYP,PER SECTOR) �� -- - -- - -_ 3527' _ YY -- :• EXTERIOR FACE OF(N)OR(E) �I I • •, / \ BUILDING OR STRUCTURE — - - -- -- -- - _ / \ (2)EX.SPARE FIBER&DC POWER CABLES IN PE PIPES L__ __ __ __ _ 40,. /t� '•�`•• ••14, ".• _ ei �C* \ TO BE CONNECTED TO NEW POWER&FIBER JUNCTION 'G. �� / III FF •• •••a A �i�i' \ CYLINDERS(TYP,PER SECTOR) — — `'7 �� I I I�hh�ONAL ENS — lei EXISTING SPRINT MMBS CABINET `� `-. _ EXISTING MEDUSA BREAKOUT CYLINDER I Iii fI • I (TYP,PER SECTOR) IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY EXISTING SPRINT - ARE ACTING UNDER THE DIRECTION OF A LICENSED BATTERY CABINET PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. I »RI DN40XC954 2077 NORTH FRONTAGE RD VAIL,CO 81657 EXISTING HYBRIFLEX CABLE ROOFTOP (TYP,PER SECTOR)(TYP,PER SECTOR) SHEET TITLE N =ft= DC DISTRIBUTION AND EXISTING GROUND BAR ANTENNA GROUNDING PLAN AND DIAGRAM SHEET NUMBER TYPICAL ANTENNA GROUNDING PLAN 24"x36" SCALE: NTS 13 TYPICAL GROUNDING RISER DIAGRAM 24"x36" SCALE: NTS 14 E-4 11"x17" SCALE: NTS 11"x17" SCALE: NTS *siti OF if 1 I TO(LOW NOISE AMPLIFIER UNITS , {4 .• 4 �\ �� (LNA)(W RECEIVE ANTENNA)AND TO TRANSMIT ANTENNAlo 2 {J j`� I �` f III0 - 2It "' I SND TYPE SS TYPE TA TYPE VB TYPE PH TYPE GR Q��namir 1° 0 0-° o p ° 4 Z11, k.42 0 7 --*.ipri.- o = RX1/RX2 RX1/RX2 SAD o 0 •0• ° ° ° p r c 3,0, ° �� \^ `� )' �• 0 ° o 0 SEE DETAIL 1 04/25/18 r ` ; ` i , - COAX JUMPER REQUIRED PER ill V I ■ MANUFACTURER'S RECOMMENDATION ■ ■ TYPE XA TYPE GT TYPE GL LUG TYPE NC TYPE PC OR FOR EASE OF CONNECTION(TYP) V i `L J-' STANDARD GROUNDING KIT,TYP.(SEE NOTE • ■ • �� ', 7 O SHEET G-2) »w� �� ' 1))))1,. L 1_-i .L L-i LEGEND: �, • �! �! \ ANTENNA CABLE TO BTS,TYP. \� :. ���pl°. CONNECTOR q 1. COPPER GROUND BAR,1/4"X 4"X 20",NEWTON INSTRUMENT CO.CAT.NO.B-6142 OR EQUAL.HOLE CENTERS TO MATCH NEMA i.M. ,� 1� 1, 11..,:;, PF /�\� �/�\ 41114W lll, . ' l WEATHERPROOFING DOUBLE LUG CONFIGURATION.(ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER OF GROUND CONNECTIONS) . Sr. e ll.' �,, KIT,TYP. \ \ ,� 6AWG STRANDED COPPER 2. INSULATORS,NEWTON INSTRUMENT CAT.NO.3061-4OR EQUAL �% .� .� �- CONDUCTOR WITH GREEN,600V, _- TYPE PG TYPE LJ TYPE HA TYPE VS TYPE NX1 � THWN-2 INSULATION G.. • 4 , �",, i 3. 5/8"LOCKWASHERS,NEWTON INSTRUMENT CO.CAT.NO.3015-8 OR EQUAL WALL MOUNTING BRACKET,NEWTON INSTRUMENT CO. )`, irk � FROM LNA(WHEN REQUIRED) - \ \ \ \\ GROUNDING BAR,ANDREW PART# CAT NO.A-6056 OR EQUAL ,®/ ,. d \ UGBKIT-0424-T(TINNED).A LOCKBOX IS •• ; 4. 5/8-11 X 1"HHCS BOLTS,NEWTON INSTRUMENT CO.CAT NO.3012-1 OR EQUAL W1 00. 0 O REQUIRED AT GRADE TASSCO PART# ■■■.squared ' 4�'1,,,. 351546.ANTENNA HEIGHT WILL DETERMINE 5. INSULATORS SHALL BE ELIMINATED WHEN BONDING DIRECTLY TO TOWER/MONOPOLE STRUCTURE.CONNECTION TO ENGINEERS �► COMM I NUMBER OF GROUNDING BARS AND THEIR k' 2 AWG TINNED,SOLID COPPER LOCATION TOWER/MONOPOLE STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS 1387 CALLE AVANZADO CONDUCTOR EXOTHERMIC WELD TO GROUNDING BUS SAN CLEMENTE,CA 92673 TYPE RR a q_---- _ (619)997-4012 TYPICAL CADWELD TYPES 24"x36" SCALE NTS 7 GROUNDING BAR CONNECTION 11""x17"" SCALE: NTS 4 GROUNDING BAR DETAIL 24"x36" SCALE: NTS 1N. 11"x17" SCALE: NTS 11"x17" SCALE: NTS / NOTES: EXTERNAL INSPECTION WINDOW BUTT CONDUCTORBEND DRAWN BY: DM INSULATION UP AGAINST 1. ALWAY IDIRECT GROUND IREDOTNTO GROUND D TOOTHED REQUIRED FOR ALL THE CONNECTOR BARREL ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. CHECKED BY: MM INTERIOR TWO-HOLE ANTENNA(TYP.),NUMBER OF 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS 3/8°0X1 1/2" CONNECTORS ANTENNAS REPRESENTED IN SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER 1 S/S NUT IN MIN' 1/t" , , THIS DETAIL ARE FOR SHOWING MCLARITY OF GROUND SYSTEM T&B CO."C-TAP",CAT.#54730,CRIMP REQUIREMENTS ONLY. TYPE PARALLED TAP OR EQUIVALENT S/S LOCK HEAT WASHER e e SHRIN\ S/S FLAT ���� ���� WASHER 111 ill ® LABEL1.L. Il \_\ 1/2"COAX JUMPER MIN.#6 AWG STRANDED(GREEN JACKET)COPPER GROUND WIRE HEAT SHRINK (BONDED TO GROUND BAR,TYP.) SEE NOTE W NOT �� TINNED COPPER - DISCONNECT RRU PER1- \ _ GROUNDING BAR PLAN(TYP) HEAT SHRINK: TOWER GROUND BAR DIRECTION OF BOND TO TURN TO 0 09/05/2017 100%CD'S-BP SUBMITTAL INDOOR - CLEAR SHORTEST DISTANCE TO MGB A 08/07/2017 90%CD FOR REVIEW OUTDOOR - BLACK `REV DATE DESCRIPTION #2 AWG BARE COPPER "DO NOT DISCONNECT"" e GROUND CONDUCTOR TO #6 AWG GREEN INSULATED r \ TAG ON ALL GROUNDING ANTENNA GROUND BAR °°00° °°°°°°I °°`° 3033°° MASTER GROUND BAR STRANDED COPPER WIRE(UNIT _ EEAR QUALIZERSONNECTS AND BOND) .4.11% DO ICe47S1� #2AWG GREEN STRANDED .. i% •••........••• D 1 CONDUCTOR \ , 0..0. . A. WNA... Vi 1l 24"x36" SCALE: NTS 24"x36" SCALE: NTS 24"x36" SCALE: NTS % �••���� '�' 7A GROUND LUG TO BUS BAR 11"x17" SCALE: NTS 8 ANTENNA GROUNDING PLAN "x,7" SCALE: NTS 5 GROUNDING WIRE CONNECTION 11"x17" SCALE: NTS 2 r i 3527' r4 NOTES: iiiim eiri . S 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND �, �, #6 AWG FROM ANTENNA ,A,, ^• • #// ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND CABLE GROUND KIT — �` �S• • i i� mil �' U( 0: / •4 .•. A.Vii, BAR. i' 1 i' i' i, ••.... 1- 2. WEATHER PROOFING SHALL BE ANDREWS. (TYPE Sc FILM p.--0.. - - -� .. - 1��1�\ ...... °/0\"E�G\��PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLEMANUFACTURER.) • � � ii COAX GROUNDING KITS RRU TO ANTENNAS TYPICAL(6) FL GROUND O BAR N WALL, - - - - - FLOOR OR ON ANTENNA ITSA VIOLATION OF LAW PERSON,UNLESS THEY D MTC 976715-15' TOWER SEE DETAIL 3 ARE ACTING UNDER THE DIRECTION OF A LICENSED MTC 976720-20' \ PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. i Y I�i TOTAL OF 6 LINES PER nnrn nn /--\ ` ' t • ❑ HASSECT BOTH 800 &OR IF THE ITE900 IN3"FLEXIBLE CONDUIT OO OO OO O OO OO OO DN40XC954 WEATHERPROOFING ■ q ANTENNA CABLE 0O 0O ©O DO O OO O O 2077 NORTH FRONTAGE RD I I _„/� J __J J VAIL,CO 81657 KIT (TYP.) TO CABINET (TYP.) O ROOFTOP G1 iI" II 3"SCHED.40 PVC /// STANDARD GROUND #6 AWG J\�GROUND CONDUCTOR SHALL BE ELIMINATED WHEN SHEET TITLE KIT (TYP.) 1r.r-1 *TWO HOLE LUG,OR EXOTHERMIC WELD TO BE / GROUND BAR IS ELECTRICALLY BONDED TO METAL ANTENNA GROUND 1�1 USED WITH#2 AWG BCW TO WATER TANK TOWER MONOPOLE STRUCTURE ■ ■ WATER MAIN OR GROUND RING BAR. MOUNT TWO HOLE LONG BARREL GROUNDING DETAILS GROUND BAR NEAR ONTRACTOR TO VERIFY THAT COMPRESSION LUGS TOP OF MONOPOLE, THE GROUND BAR IS GROUNDED TOWER OR ON ROOF TO THE TOWER OR RING L BB *-GROUND BARS AT THE BOTTOM OF TOWERS/MONOPOLES SHEET NUMBER SHALL ONLY USE EXOTHERMIC WELDS. -5 E TYPICAL COAX GROUNDING1"x17" SCALE: NTS 9 COAX GROUND KIT Z4„x;�;; SEAS NTS 16 WIRE TO GROUND BAR CONNECTION ;4x3;.. SATE: NTS 3 ,siti OF iv, THESE OUTLINE SPECIFICATIONS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPECIFICATIONS,INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE PERFORMED BY THE CONTRACTOR. 141 SECTION 01 100-SCOPE OF WORK: (VI)POWER CABINET,DOORS OPEN,BATTERIES INSTALLED 1.FASTENING MAIN HYBRID CABLES:ALL CABLES SHALL BE PERMANENTLY FASTENED TO THE COAX LADDER AT 4'-0'OC USING M. (VII)BREAK OUT CYLINDERS NON-MAGNETIC STAINLESS STEEL CLIPS. CC R1� THE WORK: (VIII)ASR SIGNAGE FOR SPRINT OWNED TOWERS �+ SHALL COMPLY WITH APPLICABLE NATIONAL CODES AND STANDARDS,LATEST EDITION AND PORTIONS THEREOF. (IX)RADIATION EXPOSURE WARNING SIGNS 2.FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE(MEDUSA),WITHIN THE MMBS CABINET AND �a (X) PHOTOGRAPH FROM EACH SECTOR FROM APPROXIMATELY RAD CENTER OF ANY NEW ANTENNA AT HORIZON. ANY INTERMEDIATE DISTRIBUTION BOXES: PRECEDENCE: Or SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES AND THE b.LOAD PHOTOS TO SITERRA PROJECT LIBRARY 15.IN 15 CREATE NEW CATEGORY;2.5 DEPLOYMENT AND SECTION;PERMANENT a.FIBER:SUPPORT FIBER BUNDLES USING 1/2"VELCRO STRAPS OF THE REQUIRED LENGTH O 18"OC.STRAPS SHALL BE 7 CONSTRUCTION DRAWINGS,INFORMATION ON THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE. CONSTRUCTION.LABEL PHOTOS WITH SITE CASCADE AND VIEW BEING DEPICTED.CAMERAS USED TO TAKE PHOTOGRAPHS SHALL UV,OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR S p r I01J 11 GPS ENABLED SUCH THAT THE GPS COORDINATED ARE INCLUDED IN THE PHOTO MEDIA-FILE INFORMATION. APPROVED EQUAL SITE FAMILIARITY: CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS,FIELD CONDITIONS AND COMMISSIONING: b.DC:SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH,ZIP TIES TO BE UV STABILIZED,BLACK NYLON, 04/25/18 DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. PERFORM ALL COMMISSIONING AS REQUIRED BY APPLICABLE MOPS WITH TENSILE STRENGTH AT 12,000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL. ON-SITE SUPERVISION: INTEGRATION: 3.FASTENING JUMPERS:SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES USING STAINLESS STEEL TIE WRAPS OR THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS, PERFORM ALL INTEGRATION ACTIVITIES AS REQUIRED BY APPLICABLE MOPS STAINLESS STEEL BUTTERFLY CLIPS. • TECHNIQUES,SEQUENCES,AND PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SECTION 07 500-ROOF CUTTING,PATCHING AND REPAIR 4.CABLE INSTALLATION: DRAWINGS,SPECIFICATIONS AND DETAILS REQUIRED AT JOBSITE: THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS AT THE JOBSITE FROM SUMMARY: a.INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE,NOTIFY THE CONSTRUCTION MANAGER. MOBILIZATION THROUGH CONSTRUCTION COMPLETION. THIS SECTION SPECIFIES CUTTING AND PATCHING EXISTING ROOFING SYSTEMS WHERE CONDUIT OR CABLES EXIT THE I A.DETAILS ARE INTENDED TO SHOW DESIGN INTENT.PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO PROVIDE A BUILDING-MOUNTED ANTENNAS,AND AS REQUIRED FOR WATERTIGHT PERFORMANCE.ROOFTOP ENTRY OPENINGS IN MEMBRANE b.CABLE ROUTING:CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED e---) �% ROOFTOPS SHALL BE CONSTRUCTED TO COMPLY WITH LANDLORD,ANY EXISTING WARRANTY,AND LOCAL JURISDICTIONAL IN THE CABLE ENVELOP AS INDICATED ON THE DRAWINGS. E1j :,I',.-�•.-.j COMPLETE AND FUNCTIONING SYSTEM.MODIFICATIONS MAYBE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS,AND STANDARDS. SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. c.HOIST CABLE USING PROPER HOISTING GRIPS.DO NOT EXCEED MANUFACTURERS RECOMMENDED MAXIMUM BEND IG` ?. 1.4 SUBMITTALS: RADIUS. '`.`-�. ,• 4.-/B.CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO PROCEEDING WITH THE rte% WORK.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE.MODIFICATIONS MAY BE REQUIRED TO A.PRE-CONSTRUCTION ROOF PHOTOS:COMPLETE A ROOF INSPECTION PRIOR TO THE INSTALLATION OF SPRINT EQUIPMENT 5.GROUNDING OF TRANSMISSION LINES:ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED ON DRAWINGS. o� SUIT JOB DIMENSIONS OR CONDITIONS,AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. ON ANY ROOFTOP BUILD.AT A MINIMUM INSPECT AND PHOTOGRAPH(MINIMUM 3 EA.)ALL AREAS IMPACTED BY THE ADDITION .square d OF THE SPRINT EQUIPMENT. 6.HYBRID CABLE COLOR CODING:ALL COLOR CODING SHALL BE AS REQUIRED IN TS 0200 REV 4. C.MARK THE FIELD SET OF DRAWINGS IN RED,DOCUMENTING ANY CHANGES FROM THE CONSTRUCTION DOCUMENTS. ENGINEERS B.PROVIDE SIMILAR PHOTOGRAPHS SHOWING ROOF CONDITIONS AFTER CONSTRUCTION(MINIMUM 3 EA.) 7.HYBRID CABLE LABELING:INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA-NUMERICALLY ACCORDING TO METHODS OF PROCEDURE(MOPS)FOR CONSTRUCTION: SPRINT CELL SITE ENGINEERING NOTICE-EN 2012-001 REV 4. 1387 CALLE AVANZADO CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN THE FOLLOWING INSTALLATION AND COMMISSIONING MOPS. C.ROOF INSPECTION PHOTOGRAPHS SHOULD BE UPLOADED WITH CLOSEOUT PHOTOGRAPHS. SAN CLEMENTE,CA 92673 WATERPROOFING EXTERIOR CONNECTORS AND HYBRID CABLE GROUND KITS: (619)997-4012 A.TOP HAT SECTION 09 900-PAINTING B.HOW TO INSTALL A NEW CABINET A.ALL FIBER&COAX CONNECTORS AND GROUND KITS SHALL BE WATERPROOFED. C.BASE BAND UNIT IN EXISTING UNIT QUALITY ASSURANCE: D.INSTALLATION OF BATTERIES B.WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS.ALL INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH E.INSTALLATION OF HYBRID CABLE A.COMPLY WITH COVERING CODES AND REGULATIONS,PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. F.INSTALLATION OF RRU'S BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS.USE EXPERIENCED INSTALLERS.DELIVER,HANDLE,AND G.CABLING STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1.COLD SHRINK:ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A DOUBLE WRAP OF 2"ELECTRICAL H.TS-0200 REV 4-ANTENNA LINE ACCEPTANCE STANDARDS TAPE EXTENDING 2"BEYOND TUBING,PROVIDE 3M COLD SHRINK CXS SERIES OR EQUAL. I.SPRINT CELL SITE ENGINEERING NOTICE-EN 2012-001,REV 1. B.COMPLY WITH ALL ENVIRONMENTAL REGULATIONS FOR VOLATILE ORGANIC COMPOUNDS. DRAWN BY: DM J.COMMISSIONING MOPS 2.SELF-AMALGAMATING TAPE:CLEAN SURFACES.APPLY A DOUBLE WRAP OF SELF-AMALGAMATING TAPE 2"BEYOND K.GROUNDING NE-312-201 MATERIALS: CONNECTOR.APPLY A SECOND WRAP OF SELF-AMALGAMATING TAPE IN OPPOSITE DIRECTION.APPLY DOUBLE WRAP OF CHECKED BY: MM L.SPRINT INTEGRATED CONSTRUCTION STANDARDS VERSION 4.0 2"WIDE ELECTRICAL TAPE EXTENDING 2"BEYOND THE SELF-AMALGAMATING TAPE. A.MANUFACTURERS:BENJAMIN MOORE,ICI DEVOE COATINGS,PPG,SHERWIN WILLIAMS OR APPROVED EQUAL.PROVIDE SECTION 01 200-COMPANY FURNISHED MATERIAL AND EQUIPMENT PREMIUM GRADE,PROFESSIONAL-QUALITY PRODUCTS FOR COATING SYSTEMS. 3.3M SLIM LOCK CLOSURE 716:SUBSTITUTIONS WILL NOT BE ALLOWED. , 1 COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE CONSTRUCTION DRAWINGS. PAINT SCHEDULE: 4.OPEN FLAME ON JOB SITE IS NOT ACCEPTABLE CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS PROTECTED AND HANDLED A.EXTERIOR ANTENNAS AND ANTENNA MOUNTING HARDWARE:ONE COAT OF PRIMER AND TWO FINISH COATS.PAINT FOR SECTION 11 800-INSTALLATION OF MULTIMODAL BASE STATIONS(MMBS)AND RELATED EQUIPMENT PROPERLY THROUGHOUT THE CONSTRUCTION DURATION. ANTENNAS SHALL BE NON-METALLIC BASED AND CONTAIN NO METALLIC PARTICLES.PROVIDE COLORS AND PATTERNS AS REQUIRED TO MASK APPEARANCE OF ANTENNAS.ON ADJACENT BUILDING SURFACES AND AS ACCEPTABLE TO THE OWNER, SUMMARY: CONTRACTOR IS RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR CONTRACTORS LOCATION. REFER TO ANTENNA MANUFACTURER'S INSTRUCTIONS WHENEVER POSSIBLE. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION IN ACCORDANCE WITH COMPANY PRACTICE. A.THIS SECTION SPECIFIES MMBS CABINETS,AND INTERNAL EQUIPMENT INCLUDING BY NOT LIMITED TO RECTIFIERS,POWER B.ROOF TOP CONSTRUCTION:TOUCH UP-PREPARE SURFACES TO BE REPAIRED.FOLLOW INDUSTRY STANDARDS AND DISTRIBUTION UNITS,BASE AND UNITS,SURGE ARRESTORS,BATTERIES,AND SIMILAR EQUIPMENT FURNISHED BY THE SECTION 01 300-CELL SITE CONSTRUCTION REQUIREMENTS OF OWNER TO MATCH EXISTING COATING AND FINISH. COMPANY FOR INSTALLATION BY THE CONTRACTOR(OFCI). NOTICE TO PROCEED: PAINTING APPLICATION: B.CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR NO WORK SHALL COMPLETE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF WORK ORDER. INSTALLATION EQUIPMENT IN EXISTING CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE 1.INSPECT SURFACES,REPORT UNSATISFACTORY CONDITIONS IN WRITING;BEGINNING WORK MEANS ACCEPTANCE OF APPLICABLE INSTALLATION MOPS. SITE CLEANLINESS: SUBSTRATE. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL,DEBRIS,AND TRASH.AT THE COMPLETION OF C.COMPLY WITH MANUFACTURERS INSTALLATION AND START-UP REQUIREMENTS. THE WORK,CONTRACTOR SHALL REMOVE FROM THE SITE ALL REMAINING RUBBISH,IMPLEMENTS,TEMPORARY FACILITIES,AND 2.COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS FOR PREPARATION,PRIMING AND COATING SURPLUS MATERIALS. WORK.COORDINATE WITH WORK OF OTHER SECTIONS. DC CIRCUIT BREAKER LABELING 1 03/05/2018 100%CD'S-REVISED SECTION 01 400-SUBMITTALS&TESTS 3.MATCH APPROVED MOCK-UPS FOR COLOR,TEXTURE,AND PATTERN.RE-COAT OR REMOVE AND REPLACE WORK WHICH A.LABEL CIRCUIT BREAKERS ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE-EN 2012-001,REV 1. 0 10/30/2017 100%CD'S-BP SUBMITTAL DOES NOT MATCH OR SHOWS LOSS OF ADHESION. A 08/07/2017 90%CD FOR REVIEW ALTERNATES: SECTION 11 800-INSTALLATION OF MULTIMODAL BASE STATIONS(MMBS)AND RELATED EQUIPMENT AT THE COMPANY'S REQUEST,ANY ALTERNATIVES TO THE MATERIALS OR METHODS SPECIFIED SHALL BE SUBMITTED TO SPRINTS 4.CLEAN UP,TOUGH UP AND PROTECT WORK. `REV DATE DESCRIPTION CONSTRUCTION MANAGER FOR APPROVAL.SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING.NO SUMMARY: VERBAL APPROVALS WILL BE CONSIDERED. TOUCHUP PAINTING: A.THIS SECTION SPECIFIES MMBS CABINETS,POWER CABINETS,AND INTERNAL EQUIPMENT INCLUDING BY NOT LIMITED TO TESTS AND INSPECTIONS: 1.GALVANIZING DAMAGE AND ALL BOLTS AND NUTS SHALL BE TOUCHED UP AFTER TOWER ERECTION WITH"GALVANOX","DRY RECTIFIERS,POWER DISTRIBUTION UNITS,BASE BAND UNITS,SURGE ARRESTORS,BATTERIES,AND SIMILAR EQUIPMENT F _ A.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS,INSPECTION AND PROJECT DOCUMENTATION. GALY",OR"ZINGIT". FURNISHED BY THE COMPANY FOR INSTALLATION BY THE CONTRACTOR(OFCI). =os%WO LICE* 1� 2.FIELD TOUCHUP PAINT SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. B.CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR i 1 B.CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 3.ALL METAL COMPONENTS SHALL BE HANDLED WITH CARE TO PREVENT DAMAGE TO THE COMPONENTS,THEIR INSTALLATION INSTALLATION NT IIN EXISTINGN CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE k• w D 11I P�� N4.••• I 1.COAX SWEEPS AND FIBER TESTS PER TS-0200 REV 4 ANTENNA LINE ACCEPTANCE STANDARDS. PRESERVATIVE TREATMENT,OR THEIR PROTECTIVE COATINGS. / •�� C.COMPLY WITH MANUFACTURERS INSTALLATION AND START-UP REQUIREMENTS. / I II MADE-FOAZIMUTH R THE PURPOSE ELEAND ICTRONIC ANTENNA ALT PROVIDE AN LIGNMENT TOOL(AAATED REPORT O�INSTALLLED AZIMUTH,CENTERLINE ANDED TO SITERRA USING A L SECTION 11 700-ANTENNA ASSEMBLY,REMOTE RADIO UNITS AND CABLE INSTALLATION SUPPORTING DEVICES: i 3527' . 7- DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA. SUMMARY: THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS,RRU'S,AND CABLE EQUIPMENT,INSTALLATION,AND TESTING OF COAXIAL A.MANUFACTURED STRUCTURAL SUPPORT MATERIALS:SUBJECT TO COMPLIANCE WITH REQUIREMENTS,PROVIDE , • • / 3.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY WORK IDENTIFIED AS FIBER CABLE. PRODUCTS BY THE FOLLOWING: II i� .• UNACCEPTABLE IN SITE INSPECTION ACTIVITIES AND/OR AS A RESULT OF TESTING. 6ANTENNAS AND RRU'S: 1.ALLIED TUBE AND CONDUIT / 111 F�s•••••••• •••\\`,. 4.ALL TESTING REQUIRED BY APPLICABLE INSTALLATION MOPS. THE NUMBER AND TYPE OF ANTENNAS AND RRU'S TO BE INSTALLED IS DETAILED ON THE CONSTRUCTION DRAWINGS. <-J, \\er 2.B-LINE SYSTEM C.REQUIRED CLOSEOUT DOCUMENTATION INCLUDES,BUT IS NOT LIMITED TO THE FOLLOWING: HYBRID CABLE: 1I1\‘�0�" ,.- HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH SITE.CABLE SHALL BE INSTALLED PER THE 3.SUNISTRUT DIVERSIFIED PRODUCTS 1.AZIMUTH,DOWNTILT,AGL FROM SUNSIGHT INSTRUMENTS-ANTENNA ALIGNMENT TOOL(ATT) CONSTRUCTION DRAWINGS AND THE APPLICABLE MANUFACTURER'S REQUIREMENTS. 4.THOMAS&BETTS IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY 2.SEEP AND FIBER TESTS JUMPERS AND CONNECTORS: ARE ACTING UNDER THE DIRECTION OFA LICENSED FURNISH AND INSTALL 1/2"COAX JUMPER CABLES BETWEEN THE RRU'S AND ANTENNAS.JUMPERS SHALL BE TYPE LDF 4,FLC 12-50, B.FASTENERS:TYPES,MATERIALS,AND CONSTRUCTION FEATURES AS FOLLOWS: PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. 3.SCANABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED EQUIPMENT CR 540,OR FXL 540.SUPER-FLEX CABLES ARE NOT ACCEPTABLE.JUMPERS BETWEEN THE RRU'S AND ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM DIELECTRIC,OUTDOOR RATED COAXIAL CABLE.DO NOT USE SUPER-FLEX 1.EXPANSION ANCHORS:CARBON STEEL WEDGE OR SLEEVE TYPE. 4.ALL AVAILABLE JURISDICTIONAL INFORMATION OUTDOORS.MAXIMUM OF 4 FEET EXCESS PER JUMPER AND HAVE CONNECTORS AT EACH END,MANUFACTURED BY SUPPLIER.IF JUMPERS ARE FIELD FABRICATED,FOLLOW MANUFACTURER'S REQUIREMENTS FOR INSTALLATION OF CONNECTORS. 2.POWER-DRIVEN THREADED STUDS:HEAT-TREATED STEEL,DESIGNED SPECIFICALLY FOR THE INTENDED SERVICE. 5.PDF SCAN REDLINES PRODUCED IN FIELD REMOTE ELECTRICAL TILT(RET)CABLES: 3.FASTEN BY MEANS OF WOOD SCREWS ON WOOD. DN40XC954 6.A PDF SCAN OF RELINE MARK-UPS SUITABLE FOR USE IN ELECTRONIC AS-BUILT DRAWING PRODUCTION MISCELLANEOUS: 4.TOGGLE BOLTS ON HOLLOW MASONRY UNITS. 2077 NORTH FRONTAGE RD 7.LIEN WAIVERS INSTALL SPLITTERS,COMBINERS,FILTERS PER RF DATA SHEET,FURNISHED BY SPRINT. VAI L,CO 81657 5.CONCRETE INSERTS OF EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY. 8.FINAL PAYMENT APPLICATION ANTENNA INSTALLATION: ROOFTOP THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDANCE WITH THE INSTRUCTIONS SUPPLIED BY THE 6.MACHINE SCREWS,WELDED THREADED STUDS,OR SPRING-TENSION CLAMPS ON STEEL. 9.REQUIRED FINAL CONSTRUCTION PHOTOS MANUFACTURER,ANTENNA HEIGHT,AZIMUTH,AND FEED ORIENTATION INFORMATION SHALL BEA DESIGNATED ON THE CONSTRUCTION DRAWINGS. 7.EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE PERMITTED. I 10.CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS A.THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE MOUNTS SO THAT THE BOTTOM STRUT IS LEVEL.THE 8.DO NOT WELD CONDUIT,PIPE STRAPS,OR ITEMS OTHER THAN THREADED STUDS TO STEEL STRUCTURES. SHEET TITLE 11.ALL POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SITERRA(SPRINTS DOCUMENT REPOSITORY PIPE MOUNTS SHALL BE PLUMB TO WITHIN 1 DEGREE. OF RECORD. 9.IN PARTITIONS OF LIGHT STEEL CONSTRUCTION,USE SHEET METAL SCREWS. 12.CLOSEOUT PHOTOGRAPHS: B.ANTENNA MOUNTING REQUIREMENTS:PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS. SUPPORTING DEVICES: GENERAL NOTES HYBRID CABLE INSTALLATION: a.PROVIDE PHOTOGRAPHS OF FINAL PROJECT PER THE FOLLOWING LIST.ADDITIONAL PHOTOGRAPHS MAY BE A. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH • REQUIRED TO SUPPORT ACCEPTANCE PROCESSES A.THE CONTRACTOR SHALL ROUTE,TEST,AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN NEC. ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES. r SHEET NUMBER N (I) MAIN HYBRID CABLE ROUTE(MINIMUM TWO PHOTOS) C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS,FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE (I) PHOTOS OF EACH ANTENNA AND RRU B.THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE MANUFACTURER'S SPECIFICATIONS FOR BENDING SECURELY TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING: (III)MANUFACTURERS NAME TAG FOR ALL SERIALIZED EQUIPMENT RADII. D. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT OF THE PROOF TEST LOAD. GN.1 (IV)PULL AND DISTRIBUTION BOXES INTERMEDIATE BETWEEN RRU'S AND MMBS(DOOR OPEN) E. USE VIBRATION AND SHOCK-RESISTANT FASTENERS FOR ATTACHMENTS TO CONCRETE SLABS. (V) MMBS CABINET WITH DOOR OPEN SHOWING MODIFICATIONS C.EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION. ELECTRICAL IDENTIFICATION: 141 A.UPDATE AND PROVIDE TYPED CIRCUIT BREAKER SCHEDULES IN THE MOUNTING BRACKET,INSIDE DOORS OF AC PANEL BOARDS WITH ANY CHANGES MADE TO THE AC SYSTEM. R1� B.BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PANELBOARD. 1a SECTION 26200-ELECTRICAL MATERIALS AND EQUIPMENT Sprap V CONDUIT: V L! A.RIGID GALVANIZED STEEL(RGS)CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN 04/25/18 UNFURNISHED INTERIOR LOCATIONS AND FOR ENCASED RUNS IN CONCRETE.RIGID CONDUIT AND FITTINGS SHALL BE STEEL, COATED WITH ZINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS.CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1,FEDERAL SPECIFICATION WW-C-581 AND SHALL BE LISTED WITH THE UNDERWRITERS'LABORATORIES. FITTING WILL NOT BE ACCEPTABLE.RGS CONDUITS SHALL BE MANUFACTURED BY ALLIED,REPUBLIC OR WHEATLAND. B.UNDERGROUND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE(PVC)SUITABLE FOR DIRECT BURIAL AS APPLICABLE.JOINTS SHALL BE BELLED,AND FLUSH SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.CONDUIT SHALL BE CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL. C.TRANSITIONS BETWEEN PVC AND RIGID(RGS)SHALL BE MADE WITH PVC COATED METALLIC LONG SWEEP RADIUS ELBOWS. i� � D.EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED FINISHED SPACES CONCEALED IN WALLS AND CEILINGS.EMT SHALL BE MILD STEEL.ELECTRICALLY WELDED,ELECTRO-GALVANIZED OR HOT-DIPPED GALVANIZED AND PRODUCED TO ANSI '� •%G,_:,` %' SPECIFICATION C80.3,FEDERAL SPECIFICATION WW-C-563,AND SHALL BE UL LISTED.EMT SHALL BE MANUFACTURED BY -„ S • ALLIED,REPUBLIC OR WHEATLAND,OR APPROVED EQUAL.FITTING SHALL BE METALLIC COMPRESSION.SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. 1 E.LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FINAL CONNECTION TO EQUIPMENT.FITTINGS SHALL BE 1 1 W 1.s q u a re d METALLIC GLAND TYPE COMPRESSION FITTINGS,MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM.SET SCREW ENGINEERS CONNECTIONS SHALL NOT BE ACCEPTABLE.MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL NOT EXCEED 6-FEET.LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRE BY NEC.MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, 1387 CALLE AVANZADO ANACONDA METAL.HOSE OR UNIVERSAL METAL HOSE,OR APPROVED EQUAL. SAN CLEMENTE,CA 92673 F.MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH(21 MM). (619)997-4012 HUBS AND BOXES: A.AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED HUBS PROVIDE METALLIC THREADED HUBS OF THE SIZE AND CONFIGURATION REQUIRED.HUB SHALL INCLUDE LOCKNUT AND NEOPRENE 0-RING SEAL. PROVIDE IMPACT RESISTANT 105 DEGREE C PLASTIC BUSHINGS TO PROTECT CABLE INSULATION. B.CABLE TERMINATION FITTINGS FOR CONDUIT DRAWN BY: DM 1.CABLE TERMINATORS FOR RGS CONDUIT SHALL BE TYPE CRC BY O-Z/GEDNEY OR EQUAL. CHECKED BY: MM 2.CABLE TERMINATORS FOR LFMC SHALL BE ETCO-CL2075;OR MADE FOR THE PURPOSE PRODUCTS BY ROXTEC. C.EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE PLATED CAST ALLOY,HEAVY DUTY, WEATHERPROOF,DUST PROOF,WITH GASKET,PLATED IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE-HINDS WAB SERIES OR EQUAL. D.CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKET COVERS.OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR THE APPLICATION.PROVIDE CROUSE-HINDS FORM 8 OR EQUAL. E.MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN,SQUARE"D",CROUSE-HIND,COOPER,ADALET,APPLETON, O-Z GEDNEY,RACO,OR APPROVED EQUAL. SUPPLEMENTAL GROUNDING SYSTEM A.FURNISH AND INSTALL A SUPPLEMENTAL GROUNDING SYSTEM AS INDICATED ON THE DRAWINGS.SUPPORT SYSTEM WITH NON-MAGNETIC STAINLESS STEEL CLIPS WITH RUBBER GROMMETS.GROUNDING CONNECTORS SHALL BE TINNED COPPER WIRE,SIZES AS INDICATED ON THE DRAWINGS.PROVIDE STRANDED OR SOLID BARE OR INSULATED CONDUCTORS AS INDICATED. B.SUPPLEMENTAL GROUNDING SYSTEM:ALL CONNECTIONS TO BE MADE WITH CAD WELDS,EXCEPT AT EQUIPMENT USE LUGS 1 03/05/2018 100%CD'S-REVISED OR OTHER AVAILABLE GROUNDING MEANS AS REQUIRED BY MANUFACTURER;AT GROUND BARS USE TWO HOLE SPADES 0 10/30/2017 100%CD'S-BP SUBMITTAL WITH NO OX. A 08/07/2017 ..........FOR REVIEW C.STOLEN GROUND-BARS:IN THE EVENT OF STOLEN GROUND BARS,CONTACT SPRINT CM FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS. REV DATE PTION EXISTING STRUCTURE: r � A.EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS,RECEPTACLES,SWITCHES,DEVICES,BOXES,AND OTHER EQUIPMENT THAT ARE NOT TO BE UTILIZED IN THE COMPLETED PROJECT SHALL BE REMOVED OR DE-ENERGIZED AND CAPPED „to. _ \on, IN THE WALL,CEILING,OR FLOOR SO THAT THEY ARE CONCEALED AND SAFE,WALL,CEILING,OR FLOOR SHALL BE PATCHED = pIICei 1N1 TO MATCH THE ADJACENT CONSTRUCTION. '' C�•. .tis/p .6 CONDUIT AND CONDUCTOR INSTALLATION: • -t/ 4 .• II ,�A.CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED.CLOSELY FOLLOW THE LINES OF THE • STRUCTURE,MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES.CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLETS OUTLET BODIES.CONDUIT SHALL BE INSTALLED IN A NEAT I :• AND WORKMANLIKE MANNER,PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES.ALL CONDUIT SHALL BE FINISHED TO CLEAR OBSTRUCTIONS.ENDS OF CONDUIT SHALL BE TEMPORARILY CAPPED TO PREVENT CONCRETE,PLASTER OR ,,� ��,•S , q DIRT FROM ENTERING.CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE F' / nS• •S 1,, ,�, AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. / III FFn./ NAL B.CONDUCTORS SHALL BE PULLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE. III*U. 0NAL ��'�\ IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OFA LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. DN40XC954 2077 NORTH FRONTAGE RD VAIL,CO 81657 ROOFTOP SHEET TITLE GENERAL NOTES SHEET NUMBER GN-2 ,, PROJECT: DO MACRO UPGRADE .54 MI ',...k,..811. ,- 44.orlo -.C-(;) 111, I ; D � 81 Iu,orrw641Nbelow. ....wb�., -. .-...k. l: Call lief ore,you dif (• I'� J N .' Q0D015 04/25/18 SITE CASCADE: DN40XC954 Spri nt \),) ADDRESS: 2077 NORTH FRONTAGE RD � � - 11/ VAIL, CO 81657 ��.. EAGLE COUNTY V VA d m.squared LATITUDE: 39.6330075° N / 39° 37' 58.82" N ENGINEERS 1387 CALLE AVANZADO LONGITUDE: 106.414855° W /106° 24' 53.47" W SANCLEMENTE,CA92673 (619)997-4012 i / SITE TYPE: ROOFTOP DRAWN BY: DM CHECKED BY: MM SITE INFORMATION AREA MAP PROJECT DESCRIPTION DRAWING INDEX allSPRINT PROPOSES TO MODIFY AN EXISTING WIRELESS INSTALLATION.THE SCOPE WILL CONSIST PROPERTY OWNER: BRANDESS ENTERPRISES LLCliv OF THE FOLLOWING: SHEET NO: SHEET TITLE P.O.BOX 3017 • REMOVE (3) EXISTING SPRINT PANEL ANTENNAS T-1 TITLE SHEET LIHUE,HI 96766-3017 • NSTALL (3) NEW SPRINT TRI-BAND PANEL ANTENNAS GN-1 GENERAL NOTES • NSTALL (3) NEW SPRINT RRU @ ANTENNA LEVEL so • NSTALL (4) NEW SPRINT BATTERIES IN EXISTING BBU CABINET GN-2 GENERAL NOTES APPLICANT: SPRINT u� • NSTALL (3) NEW SPRINT POWER JUNCTION CYLINDERS • NSTALL (3) NEW SPRINT FIBER JUNCTION CYLINDERS A-1 SITE PLAN AND ENLARGED SITE PLAN ` • NSTALL (1) NEW SPRINT 2.5GHz BASEBAND UNIT IN EXISTING MMBS CABINET A-2 EQUIPMENT LAYOUT LAT/LONG TYPE: NAD-83 • NSTALL (3) NEW SPRINT QUADPLEXER - • NSTALL (2) NEW SPRINT ANTENNA WALL MOUNTS A-3 ANTENNA LAYOUT LATITUDE: 39.633007W N/39°37'58.82"N A-4 ELEVATIONS LONGITUDE: 106.414855°W/106°24'53.47"W A-5 COLOR CODING r ZONING JURISDICTION: TOWN OF VAIL D-1 EQUIPMENT DETAILS 1 03/05/2018 100%CD'S-REVISED ZONING CLASSIFICATION: COMMERCIAL f D-2 EQUIPMENT DETAILS 0 10/30/2017 100%CD'S-BP SUBMITTAL j D-3 EQUIPMENT DETAILS CURRENT USE: UNMANNED TELECOMMUNICATIONS FACILITY c , _ A 08/07/2017 90%CD FOR REVIEW t E-1 GENERAL ELECTRICAL NOTES ASSESSOR'S PARCEL NO.: 2103-123-02-025 REV DATE DESCRIPTIONE-2 ONE-LINE DIAGRAM PROPOSED USE: UNMANNED TELECOMMUNICATIONS FACILITY E-3 PANEL SCHEDULE e N TYPE OF CONSTRUCTION: V-B { E-4 ANTENNA GROUNDING PLAN AND DIAGRAM —��� OCCUPANCY GROUP: U-2 \��� • N. . N E-5 GROUNDING DETAILS i17\ o IICFys h�, RF-1 RADIO FREQUENCY DATA SHEET •••N••••••M(CD y gild %� r'0.A• Wyq':• 16) W a E � G ��I S / 3527' _ / ••• /�, PROJECT TEAM LOCATION MAP APPLICABLE CODES APPROVALS �� F••., ..•• 4.A, REAL ESTATE MANAGER: ENGINEER: h •� -'1. ? . •rr � ..� „ r TO PROCEEDTHE WITH THE CONSTRUCTNG PARTIES HEREBY ION DESCRIBED HEREIN.ALL DOCUMENTS ARE SUBPROVE AND ACCEPT THESE DOCUMENTS& JECT TO REVIEW BY IZE THE SUBCONTRACTOR 1��‘‘‘519/0A1 AL EN�- A _ ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CONTACT:CHRISTINE POULIGNOT M.SQUARED ENGINEERS l { �N._ CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING LOCAL BUILDING DEPARTMENT&MAY IMPOSE CHANGES OR MODIFICATIONS. \‘‘������ REAL ESTATE MANAGER-COLORADO 1387 CALLE AVANZADO - ` - p - AUTHORITIES.NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING _ SPRINT NEXTEL CORPORATION SAN CLEMENTE,CA 92673 • . -- • _• - . V-�`- TO THESE CODES: CIO CHRISTINE POULIGNOT CONTACT:MICHAEL MONTELLO r a -,. - - �; ° r Al- IT 15 A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY MAILSTOP:INCOENGJO201 EMAIL:micMI l@m2-eng.COm .•r.'; _ " d• • 2015 INTERNATIONAL BUILDING CODE SPRINT RF ENGINEER: DATE: ARE ACTING UNDER THE DIRECTION OF A LICENSED 333 INVERNESS DRIVE SOUTH • ='s` - '1+ • 2014 NATIONAL ELECTRICAL CODE PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. ENGLEWOOD,CA 80112 r • LOCAL BUILDING CODES • PH:(720)329-7993 RF ENGINEER: • 4 • • CITY/COUNTY ORDINANCES SPRINT OPERATIONS: DATE: EMAIL:christine.poulignot@sprint.com �� CONTACT:NEERAJ BERI PH:(440)222-8729 g' e SITE ACQUISITION EMAIL:neeraj.beri@sprint.com SITE ACQUISITION: DATE: M SQUARED ENGINEERS •� • - - DN40XC954 CONTACT:FELICIA PHILLIPS �' ; - CONSTRUCTION MANAGER: DATE: 2077 NORTH FRONTAGE RD 1387 CALLE AVANZADO \ - - - SAN CLEMENTE,CA 92673 CONSTRUCTION MANAGER: • VAIL,CO 81657 PH:(714)791-6643 CONTACT:BRANDON WHINERY ROOFTOP EMAIL:felicia@m2-eng.com PH:(303)505-5750 • - PROPERTY OWNER: DATE: EMAIL:brandon.whinery@sprint.com .. ala' I ZONING: DATE: • ` __ SHEET TITLE ' PROJECT MANAGER: — DATE: GENERAL NOTES I ice` • :a4 + '' TITLE SHEET THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.HANDICAPPEDSA. • Y ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2015 f " _ INTERNATIONAL BUILDING CODE.A TECHNICIAN WILL VISIT THE SITE AS '•"S'h •'1. I``'` - DO NOT SCALE DRAWINGS REQUIRED FOR ROUTINE MAINTENANCE.THE PROJECT WILL NOT RESULT IN ANY ,,,r;,41M _ .- ' w OA- \' SHEET NUMBER SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE;NO SANITARY SEWER • .t• ; 1�'-\•f4I0� SUBCONTRACTOR SHALL VERIFY ALL PLANS,EXISTING DIMENSIONS&FIELD CONDITIONS ON THE JOB SITE& T 1 SERVICE,POTABLE WATER,OR TRASH DISPOSAL IS REQUIRED AND NO - ¢ - SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE COMMERCIAL SIGNAGE IS NEW. .•A . • " WORK OR BE RESPONSIBLE FOR SAME. _