Loading...
HomeMy WebLinkAboutB18-0137_approved documents_1525104167.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B18-0137 Issued: 04/30/2018 TOWN OF VAIL Property Information Address: 5014 MAIN GORE DR N 1D (209918208001 1D) ( 209918208001 ) Unit #: 1D Parcel Number: 209918208001 Legal Description: DESC: BLDG D Subdivision: GORE CREEK CONDOMINIUMS Unit: 1 Contacts Contact Type: Applicant Full Name: Melissa Hewitt Address: 5014 Main Gore Drive Unit 4 Vail, CO 81657 Phone: 3038888263 Contact Type: Applicant Full Name: Jim & Elizabeth Krezowski Address: 5014 Main Gore Drive S Unit 1 Vail, CO 81657 Phone: 612-991-1338 Contact Type: Property Owner Full Name: KREZOWSKI, JAMES A. & ELIZABETH G. Address: Phone: None Contractor Contractor Type: General Company: RT Concepts State License #: Phone: 6088525403 Project Information Project Name: Krezowski Residence 2018 Project Description: Replacement of all remaining single pane aluminum windows within unit #1 described as the "front entrance window", the "trapezoid window" and the "bay window" will be replaced same for same with Milgard Tuscany white vinyl windows to match other 3 units in the building. Replace 3 windows that were recently updated with Renewal by Anderson from a previous window permit executed approximately in October of 2016, yet these windows were out of compliance with the code and are now being replaced with Milgard Tuscany white vinyl to correct the code violation and match the other 3 units. Please reference DRB18-0070 approval. Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$139.25 Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$90.51 Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00 Total Paid:$234.76 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. - Prior to requesting a final Planning Inspection, Applicant shall complete all windows as approved by the Town of Vail Design Review Board including replacement of the existing 3-pane window and windows adjacent to the fireplace, as required by the Design Review Board March 21, 2018 under permit DRB18-0070. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. PINNACLE WINDOWS & RESTORATION 1870 W 64TH LANE Suite A DENVER, CO 80221-2365 303-747-3698 Quote Number: SQPDKM002125_1 Print Date: 4/16/2018 Page 1 of 5 Quote Name: Customer: Payment Terms: Sales Representative: Comments: Jim and Liz Krezowski New Retail Dario Duque Mobile: dario@pinnaclewindowsco.com Quote Number: Created Date: Modified Date: PO Number: Total Units: Total Sq Ft: Est. Delivery: SQPDKM002125_1 3/30/2018 4/16/2018 8 116.00 _____________________ Billing Information Shipping Information Name: New Retail Name: Same as Bill-to Address: , Address: , Phone: Phone: Fax: Fax: Email: Email: Line: Quantity: 1 1 Location: Jim's Desk Tuscany, 8120T, HV, 1 3/8" Setback, Ext White /Int White U-Factor: .32, SHGC: .21, VT: .48 $310.43 1/8" SunCoatMAX (Low-E) over 1/8" Clear $28.05 Size: Net Frame 64" x 48" Net Frame 64" X 48" Model: Half Vent Handing: Half Vent XO Glass: 1/8" SunCoatMAX (Low-E) over 1/8" Clear Other Glass: Gray Foam Spacer with BreatherTube Hardware: SmartTouch Lock Other Options: Glass Breakage Warranty Screen: Standard with Fiberglass Mesh Ratings: STC: 29, OITC: 22, Tested: LC40 Clear Opening: W 29 5/16" x H 45" Sq. Ft. 9.16 Egress: Yes Other Ratings: CPD: MIL-A-224-06261-00001 Item Total: Item Qty Total: $338.49 $338.49 Viewed From Exterior Customer Approval: ____________ Quote Number: SQPDKM002125_1 Print Date: 4/16/2018 Page 2 of 5 Line: Quantity: 2 2 Location: Fireplace Tuscany, 8220T, SH, 1 3/8" Setback, Ext White /Int White U-Factor: .32, SHGC: .21, VT: .48 $294.34 Custom Glass Option $63.93 Size: Net Frame 36" x 84" Net Frame 36" X 84" Dimensions: Sash Height 23 5/8" Model: Single Hung Glass: WP 1.1 SH Unit 1.1: 1/8" SunCoatMAX (Low-E) Tempered over 1/8" Clear Tempered, WP 1.1 SH Unit 2.1: 1/8" SunCoatMAX (Low-E) over 1/8" Clear Other Glass: Gray Foam Spacer with BreatherTube Hardware: SmartTouch Lock Other Options: Glass Breakage Warranty Screen: Standard with Fiberglass Mesh Ratings: STC: 29, OITC: 22, Tested: LC35 Clear Opening: W 33" x H 18 7/8" Sq. Ft. 4.33 Other Ratings: CPD: MIL-A-225-06315-00001 Item Total: Item Qty Total: $358.26 $716.52 Viewed From Exterior Customer Approval: ____________ Line: Quantity: 3 1 Location: Entry Door Tuscany, 8320T, PW, 1 3/8" Setback, Ext White /Int White U-Factor: .31, SHGC: .29, VT: .55 $146.71 1/8" SunCoat (Low-E) Tempered over 1/8" Clear Tempered $57.49 Size: Net Frame 17" x 67" Net Frame 17" X 67" Model: Picture Glass: 1/8" SunCoat (Low-E) Tempered over 1/8" Clear Tempered Other Glass: Gray Foam Spacer with BreatherTube Other Options: Glass Breakage Warranty Ratings: STC: 31, OITC: 25, Tested: CW40 Other Ratings: CPD: MIL-A-229-08561-00001 Item Total: Item Qty Total: $204.20 $204.20 Viewed From Exterior Customer Approval: ____________ Quote Number: SQPDKM002125_1 Print Date: 4/16/2018 Page 3 of 5 Line: Quantity: 4 1 Location: Trapazoid Tuscany, 8320T, PWG4, 1 3/8" Setback, Ext White /Int White U-Factor: .31, SHGC: .22, VT: .51 $381.72 1/8" SunCoatMAX (Low-E) over 1/8" Clear $21.62 Size: Net Frame 36" x 95 1/2" Net Frame 36" X 95 1/2" Dimensions: Short Leg 69" Model: Trapezoid Handing: Trapezoid Right Glass: 1/8" SunCoatMAX (Low-E) over 1/8" Clear Other Glass: Gray Foam Spacer with BreatherTube Other Options: Glass Breakage Warranty Ratings: STC: 31, OITC: 25, No Ratings Other Ratings: CPD: MIL-A-229-08625-00004 Item Total: Item Qty Total: $403.33 $403.33 Viewed From Exterior Customer Approval: ____________ Line: Quantity: 5 1 Location: Master Bay Right Tuscany, 8520T, FC, No Fin (Block Frame), Ext White /Int White U-Factor: .29, SHGC: .25, VT: .47 $283.76 1/8" SunCoat (Low-E) over 1/8" Clear $3.22 Size: Net Frame 23 3/8" x 45 1/8" Net Frame 23 3/8" X 45 1/8" Model: Casement Handing: Casement Right Glass: 1/8" SunCoat (Low-E) over 1/8" Clear Other Glass: Gray Foam Spacer with BreatherTube Hardware: Nesting Fold Down Roto/Stainless Steel Operator Handle, Wash Hinge Other Options: Glass Breakage Warranty Screen: Standard with Fiberglass Mesh Ratings: STC: 31, OITC: 24, Tested: LC60 Clear Opening: W 11 11/16" x H 40 9/16" Sq. Ft. 3.29 Other Ratings: CPD: MIL-A-227-06317-00001 Item Total: Item Qty Total: $286.98 $286.98 Viewed From Exterior Customer Approval: ____________ Quote Number: SQPDKM002125_1 Print Date: 4/16/2018 Page 4 of 5 Line: Quantity: 6 1 Location: Master Bay Left Tuscany, 8520T, FC, No Fin (Block Frame), Ext White /Int White U-Factor: .29, SHGC: .25, VT: .47 $283.76 1/8" SunCoat (Low-E) over 1/8" Clear $3.22 Size: Net Frame 23 3/8" x 45 1/8" Net Frame 23 3/8" X 45 1/8" Model: Casement Handing: Casement Left Glass: 1/8" SunCoat (Low-E) over 1/8" Clear Other Glass: Gray Foam Spacer with BreatherTube Hardware: Nesting Fold Down Roto/Stainless Steel Operator Handle, Wash Hinge Other Options: Glass Breakage Warranty Screen: Standard with Fiberglass Mesh Ratings: STC: 31, OITC: 24, Tested: LC60 Clear Opening: W 11 11/16" x H 40 9/16" Sq. Ft. 3.29 Other Ratings: CPD: MIL-A-227-06317-00001 Item Total: Item Qty Total: $286.98 $286.98 Viewed From Exterior Customer Approval: ____________ Line: Quantity: 7 1 Location: Master Bay Center Tuscany, 8360T, PWR, No Fin (Block Frame), Ext White /Int White U-Factor: .31, SHGC: .29, VT: .55 $128.77 1/8" SunCoat (Low-E) over 1/8" Clear $3.22 Size: Net Frame 23 3/8" x 45 1/8" Net Frame 23 3/8" X 45 1/8" Model: Slider Picture Glass: 1/8" SunCoat (Low-E) over 1/8" Clear Other Glass: Gray Foam Spacer with BreatherTube Other Options: Glass Breakage Warranty Ratings: STC: No Rating, OITC: No Rating, Tested: CW50 Other Ratings: CPD: MIL-A-236-05445-00001 Item Total: Item Qty Total: $131.99 $131.99 Viewed From Exterior Customer Approval: ____________ Quote Number: SQPDKM002125_1 Print Date: 4/16/2018 Page 5 of 5 PINNACLE WINDOWS & RESTORATION 1870 W 64TH LANE Suite A DENVER, CO 80221-2365 303-747-3698 Submitted By: ___________________________ Accepted By: ___________________________ Date: ___________________________ Material Subtotal: $2,368.49 Material Tax 4.75 %: $112.50 Grand Total (USD): $2,480.99 For warranty information please visit www.milgard.com/warranty/ Please note that actual NFRC energy values may vary from those reported in CTB Quote Plus due to variations that may occur during the manufacturing process. In most cases variations will be minimal. Please contact your Milgard location with questions or concerns regarding this potential variation. Handing is viewed from outside looking in. ADDITIONAL INFORMATION: Tuscany® Series Performance Ratings Updated: 8/2014 size bs/vs bs/vs bs/vs Half Vent 6050 - LC-PG-40 0.04 6 2 0 1 6 - 6 0 5 0 - Double Vent 8060 - HS-LC-30 0.03 6 2 0 1 6 8 0 6 0 24 Double Vent 10050 36 HS-LC-25 0.1 6 3 0 3 0 10 0 5 0 36 Double Vent 13060 48 HS-R-15 0.1 6 3 0 1 6 12 13 0 6 0 48 Half Vent Below 6080 36 LC-PG-25 0.05 3.75/6.75 2 0 3 0 6 0 6 0 36 Half Vent Above 6080 36 LC-PG-25 0.03 3.75 2 0 3 0 6 0 8 0 36 Double Vent Below 10060 - HS-R-20 0.09 3.75/5.25 4 0 3 0 10 0 6 0 36 Double Vent Above 10060 - HS-R-20 0.03 3.75/5.25 4 0 3 0 10 0 6 0 36 Double Slider 8125T 6050 - HS-LC-25 0.06 3.75 2 0 1 6 6 0 5 0 Single Hung net 44 X 75 C H-LC-40 0.04 6 1 6 2 0 12 3 8 6 3 Single Hung 4080 C H-LC-35 0.16 6 1 6 2 0 12 4 0 8 0 Triple Single Hung 9077 C H-R-20 0.09 4.5 4 6 2 6 9 0 7 7 Special config - transom over O/O | O/X 6076 C H-LC-25 0.08 4.5 - 6 0 7 6 Double Hung net 44 x 75 C H-LC-30 0.28 5.25 1 6 2 0 12 3 8 6 3 37.5 Double Hung 4070 C H-LC-25 0.27 5.25 1 6 2 0 12 4 0 7 0 37.5 Double Double Hung net 83 x 66 C H-R-30 0.23 4.5 1 6 2 0 12 6 11 5 6 20 Double Double Hung - C H-LC-30 0.21 3 0 2 0 12 6 0 6 3 37.5 Triple Double Hung net 108 x 75 C H-LC-30 0.21 4 6 2 0 12 9 0 6 3 37.5 Picture Window 8060 - FW-HC-40 0.005 12 1 6 1 6 - 8 0 6 0 - Octagon - - FW-HC-40 - 12 2 0 2 0 - 6 0 6 0 - Full Round - - FW-HC-40 - 12 2 6 2 6 - 6 0 6 0 - 1/2 Round - - FW-HC-40 - 12 2 6 1 3 - 8 0 4 0 - Window Type 8220T 8230T 8240T 8270T 8120T 8130T 8140T 8170T Series - - 8225T 8320T 8330T 8340T Max Width Height Width Height Test Structural Class Air Infiltration Water * Test (PSF) Min size bs/vs bs/vs bs/vs Picture Window 6060 - FW-C-50 0.01 7.5 Octagon - FW-C-50 Full Round - FW-C-50 1/2 Round - FW-C-50 Picture Window - FW-C-50 Octagon - FW-C-50 Full Round - FW-C-50 1/2 Round - FW-C-50 Full Awning 5030 - AP-C-40 0.03 12 1 3 1 4 - 5 0 3 0 - Triple Awning - - Bottom / top Awning 5080 36 AP-C-40 0.03 12 1 3 2 6 16 5 0 8 0 36 Full Casement net 36 x 72 - C-C-45 .05 9 1 5 1 5 - 3 0 6 0 - Full Casement net 32 X 72 - C-C-50 0.07 12 1 5 1 5 - 2 8 6 0 - Full Casement net 35.5 X 60 - C-C-60 0.08 12 1 5 1 5 - 3 0 5 0 - Single Casement - Fixed Sash Casement PW 8060 - LC-PG35 0.05 9.19 2 0 2 0 8 0 6 0 Double Casement 6050 36 C-C-40 0.07 6 3 0 1 6 - 6 0 5 0 36 Double Casement w/ center PW 12060 36 C-C-35 0.09 5.25 6 0 1 6 12 0 6 0 36 SGD OX / XO 8080 - SD-C-30 0.16 4.5 5 0 6 8 - 8 0 8 0 - SGD OX / XO 100610 - SD-R-20 0.05 3 5 0 6 8 - 10 0 6 10 - SGD OXO 12080 - SD-R-20 0.19 3.75 9 0 6 8 - 12 0 8 0 - SGD OOX / XOO - - SD-R-20 0.23 4.5 9 0 6 8 - 11 8 8 0 - SGD OXXO 16080 - SD-R-20 0.07 3 10 0 6 8 - 16 0 8 0 - SGD OX / XO 8080 - SD-LC-25 0.17 3.75 5 0 6 8 - 8 0 8 0 - SGD OX / XO 60610 - SD-LC-30 0.08 4.5 5 0 6 8 - 6 0 6 10 - SGD OXO 12080 - SD-R-20 0.12 3 9 0 6 8 - 12 0 8 0 - SGD OOX / XOO 12080 - SD-R-20 0.05 3 9 0 6 8 - 12 0 8 0 - SGD OXXO 16080 - SD-R-15 0.11 3 10 0 6 8 - 16 0 8 0 - Max Width Height Width Height 8375T 8420T 8430T 8440T 8470T 8520T 8530T 8540T 8570T 8621 8631 8621F 8631F Window Type Series 8360T 8370T Test Structural Class Air Infiltration Water * Test (PSF) Min size bs/vs bs/vs bs/vs SGD Transom 8621TR 9050 - TR-LC25 0.01 6.75 5 0 1 6 - 9 0 5 0 - SGD Canada 8622 10080 - LC-PG25 0.1 5.25 5 0 6 8 - 10 0 8 0 - Inswing - XX net 76 X 95.5 - SHD-LC25 0.04 3.75 5 0 6 8 - 6 4 8 0 - Inswing - XO/OX net 76 X 95.5 SHD-LC25 0.04 3.75 5 0 6 8 6 4 8 0 Inswing - XXXX 10480 SHD-LC25 0.03 3.75 10 4 6 8 10 4 8 0 Inswing -OXXO 10480 - SHD-LC25 0.05 3.75 10 4 6 8 - 10 4 8 0 - Inswing -X _ _ _ _ _ 2 6 8 0 3 0 8 0 Inswing - Sidelite net 24 x 80 - R PG30 0.17 4.6 2 0 6 8 Outswing - XX net 76 X 95.5 SHD-LC35 0.07 5.25 5 0 6 8 6 4 8 0 Outswing - XO/OX net 76 X 95.5 - SHD-LC35 0.01 6.75 5 0 6 8 - 6 4 8 0 - Outswing - XXXX 10480 SHD-LC25 0.13 3.75 10 4 6 8 10 4 8 0 Outswing - OXXO 10480 - SHD-LC30 0.1 4.5 10 4 6 8 - 10 4 8 0 - Outswing - X _ _ _ _ _ 2 6 8 0 - 3 0 8 0 - * The water test pressures are done in a controlled environment and performance in the field may vary. Therefore, AAMA requirements should be reduced to 2/3's of the test pressure for field testing. Max Width Height Width Height Test Structural Class Air Infiltration Water * Test (PSF) Min 8643T 8663T 8642T 8662T Window Type Series Tuscany® Series STC Ratings Rev: 1/5/17 07-271 1/8 1/8 29 30 22 07-276 1/8 1/4 33 34 26 07-270 3/16 1/8 33 34 27 13-558 1/4 1/8 31 33 26 07-273 7/32 LAM 1/8 34 35 27 07-277 7/32 LAM 3/16 35 36 29 07-274 7/32 LAM 7/32 LAM 35 36 30 07-278 7/32 LAM 3/16 35 37 28 08-141 1/8 1/8 29 30 24 08-142 1/8 1/4 32 34 27 08-144 3/16 1/4 33 35 28 08-145 7/32 LAM 1/8 33 34 28 08-146 7/32 LAM 3/16 34 35 29 08-147 7/32 LAM 1/4 34 35 29 08-148 7/32 LAM 7/32 LAM 34 35 30 07-294 1/8 1/8 29 30 22 07-297 3/16 1/8 33 34 27 07-295 7/32 LAM 1/8 33 35 26 07-299 7/32 LAM 3/16 35 36 29 07-430 1/8 1/8 26 28 22 07-437 1/4 3/16 28 31 26 07-433 7/32 LAM 1/8 28 31 26 07-435 1/4 1/8 28 31 26 08-136 1/8 1/8 31 32 25 07-291 3/16 1/8 32 32 25 07-289 1/4 1/8 32 32 26 07-292 7/32 LAM 1/8 34 33 26 07-293 7/32 LAM 1/4 34 35 27 07-280 7/32 LAM 7/32 LAM 37 37 30 07-281 1/8 1/8 31 31 24 07-284 3/16 1/8 34 34 27 07-285 1/4 1/8 35 35 27 07-286 7/32 LAM 1/8 36 35 28 07-287 7/32 LAM 3/16 37 37 30 07-288 7/32 LAM 7/32 LAM 37 37 31 07-283 7/32 LAM 1/4 38 38 30 07-281 1/8 1/8 31 31 24 07-284 3/16 1/8 34 34 27 07-285 1/4 1/8 35 35 27 07-286 7/32 LAM 1/8 36 35 28 07-287 7/32 LAM 3/16 37 37 30 07-288 7/32 LAM 7/32 LAM 37 37 31 07-283 7/32 LAM 1/4 38 38 30 8320Picture Window 8420 Awning 8125 Double Slider 8220Single Hung 8225Double Hung 8120Horizontal Slider Glass 2 Glass 1 STC OITCEWR Test Number Operating Style Series Number Casement 8520 File Name: STC Ratings - Tuscany Due to continual product research and development, details listed are subject to change at any time. Tuscany® Series STC Ratings Rev: 1/5/17 Glass 2 Glass 1 STC OITCEWR Test Number Operating Style Series Number 98-366 1/8 1/8 29 29 22 98-367 1/8 1/4 33 34 28 03-216 1/8 3/16 33 34 24 98-369 1/4 3/16 33 34 28 98-371 1/8 3/16 33 34 27 98-370 1/8 7/32 LAM 34 35 29 98-368 1/8 7/32 LAM 35 35 28 98-365 7/32 LAM 7/32 LAM 35 36 29 04-165 1/8 1/8 29 29 22 04-170 3/16 3/16 31 32 25 04-166 3/16 1/8 33 33 26 04-167 1/4 1/8 33 33 27 04-168 7/32 LAM 1/8 33 34 27 04-169 7/32 LAM 7/32 LAM 34 35 28 TL11-199 0.125 0.125 30 30 24 TL11-201 0.125 0.1875 32 33 27 TL11-207 0.125 0.25 33 33 28 TL11-205 0.1875 0.25 32 34 28 TL11-203 0.125 7/32 LAM 33 34 28 TL11-209 0.1875 7/32 LAM 33 34 28 TL11-211 0.25 7/32 LAM 33 34 28 TL11-213 7/32 LAM 7/32 LAM 33 34 28 TL11-198 0.125 0.125 30 30 24 TL11-200 0.125 0.1875 32 33 27 TL11-206 0.125 0.25 33 33 28 TL11-204 0.1875 0.25 32 34 28 TL11-202 0.125 7/32 LAM 33 34 28 TL11-208 0.1875 7/32 LAM 33 34 28 TL11-210 0.25 7/32 LAM 33 34 28 TL11-212 7/32 LAM 7/32 LAM 33 34 28 8643Out-Swing French Door 8642In-Swing French Door 8621Sliding Door 8621FFrench Rail Sliding Door File Name: STC Ratings - Tuscany Due to continual product research and development, details listed are subject to change at any time. Invoice Date 3/26/2018 Invoice # 30 Bill To 5014 Main Gore DR Vail, CO 81657 unit #1 RT Concepts W 10867 West Harmony DR WI 53555 P.O. No. Terms Project Total Description Quantity Rate Amount Windows & Trim Remove and replace wrong size windows. Reframe opening to original size. replace drywall/sill inside. 3 800.00 2,400.00 Windows & Trim Remove and replace with existing size windows. Remove and reinstall Millwork on the inside. 3 600.00 1,800.00 $4,200.00