HomeMy WebLinkAboutSKMBT_C22018112612410.pdf cEd �1I l� I ii li I r1 1 =' 251 ROONEY ROAD - GOLDEN,CO 80401 Testing Laboratory t I' I , ' �� '� 1 Ph:303.216.9300-Fx:303.216.9400 Calibration Test No.: 1 FORM ENGINEERING CORP. www.williamsform.com G03140 HYDRAULIC JACK ASSEMBLY CALIBRATION -VERIFICATION REPORT 'Customer: Thorcon Shotcrete&Shoring Salesman: Joeseph Erickson Customer Order No. 243900 Jack Model No.: RH605 Service Gauge Model No:POWER TEAM Pump Model No.: ENERPAC Jack Serial No.: Yenter#68 Service Gauge Serial No.: 064 Pump Serial No.: 04099C Capacity: 60 ton Capacity Range: 0-10,000 psi Power-AIR D Elec. O Ram Area(in2): 12.31 Hand 0 Gas 0 Cal Ram Area(in2): 12.43 Calibration Date: 4/1012018 Calibration Location: Williams Form Engineering Corp,Test Lab-251 Rooney Road - Golden,CO 80401 Test Frame Load Cell No.1: HB1W-C8 Serial No.: 00287131 Hydraulic Transducer: HBM Serial No.: 52610090 Cell&Transducer calibration date:6/13/2017,Next calibration:6/13/2018,by Calibration Services Inc.,per ASTM E4 Load Cell Load Cell Load Cell Test Average Master Gauge-P3M Service Gauge Run 1 Run 2 Run 3 (lbs) (lbs) (lbs) {lbs) {psi) {psi) 12,972 12,721 12,787 12,826 1061 1000 24,799 25,144 25,279 25,074 2069 2000 37,296 37,032 37,205 37,178 3060 3000 49,748 49,253 49,475 49,492. 4067 4000 61,700 61,465 61,604 61,590 5052 5000 73,973 73,939 74,211 74,041 6059 6000 86,259 86,181 86,247 86,229 7058 7000 . 98,432 98,261 98,790 98,494 8049 8000 Hydraulic Jack Assembly Calibration Verification • 1, y=0.0817x-43,824 k 10000 9000 95494 8000.. 8000 1. .86229,7000 7000 . _ _ _ _- C. 74041,600.` 6000 1 - e 61590,5000 ta X 5000 I 49492,4000 11>6 4000 CO ,37178,30 I 7 3000 0 25074,2001 2000 - 12828,1001. 1000 I - . 0 - f 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 Load(11151 x-axis Gauge Pressure(y)= 0.0817x + -43.8239 Load(x)= 12.2398y - -538.40 rt Calibrated by: al / J j J verified by; .i•-•''''''' _ "-'�------':::> 1 `\ This Jack Calibration is issu-, -a a statement of the fact that an this date the above equipment(s)had accuracy as indicated in bie date section of this calibration.It should not be construed or regarded as a 0.,rantee or Warranty of any kind,which the equipment will continue to retain the same percentage of accuracy or efficiency as determined on the date when the calibration was performed by Williams. Operation,damage,or loss sustained by all parties arising or resulting from deterioration,obsolescence,malfunction,or substandard performance of said equipment(s)shall be and remain the sate responsibility of the equipment(s)user,renter,and/or owner.This document shall not be reproduced except in full, without written approval of Williams Form Engineering Co. RHT 08/10/12 1