HYDRAULIC JACK ASSEMBLY CALIBRATION -VERIFICATION REPORT
'Customer: Thorcon Shotcrete&Shoring Salesman: Joeseph Erickson Customer Order No. 243900
Jack Model No.: RH605 Service Gauge Model No:POWER TEAM Pump Model No.: ENERPAC
Jack Serial No.: Yenter#68 Service Gauge Serial No.: 064 Pump Serial No.: 04099C
Capacity: 60 ton Capacity Range: 0-10,000 psi Power-AIR D Elec. O
Ram Area(in2): 12.31 Hand 0 Gas 0
Cal Ram Area(in2): 12.43 Calibration Date: 4/1012018
Calibration Location: Williams Form Engineering Corp,Test Lab-251 Rooney Road - Golden,CO 80401
Test Frame Load Cell No.1: HB1W-C8 Serial No.: 00287131
Hydraulic Transducer: HBM Serial No.: 52610090
Cell&Transducer calibration date:6/13/2017,Next calibration:6/13/2018,by Calibration Services Inc.,per ASTM E4
Load Cell Load Cell Load Cell Test Average Master Gauge-P3M Service Gauge
Run 1 Run 2 Run 3
(lbs) (lbs) (lbs) {lbs) {psi) {psi)
12,972 12,721 12,787 12,826 1061 1000
24,799 25,144 25,279 25,074 2069 2000
37,296 37,032 37,205 37,178 3060 3000
49,748 49,253 49,475 49,492. 4067 4000
61,700 61,465 61,604 61,590 5052 5000
73,973 73,939 74,211 74,041 6059 6000
86,259 86,181 86,247 86,229 7058 7000 .
98,432 98,261 98,790 98,494 8049 8000
Hydraulic Jack Assembly Calibration Verification
• 1,
y=0.0817x-43,824 k
10000
9000
95494 8000..
8000
1.
.86229,7000
7000 . _ _ _ _-
C. 74041,600.`
6000 1 -
e 61590,5000
ta X 5000 I
49492,4000
11>6 4000
CO ,37178,30 I
7 3000
0 25074,2001
2000 -
12828,1001.
1000 I - .
0 - f
0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000
Load(11151
x-axis
Gauge Pressure(y)= 0.0817x + -43.8239 Load(x)= 12.2398y - -538.40
rt
Calibrated by: al / J j J verified by; .i•-•'''''''
_ "-'�------':::>
1 `\
This Jack Calibration is issu-, -a a statement of the fact that an this date the above equipment(s)had accuracy as indicated in bie date section of this calibration.It should not be
construed or regarded as a 0.,rantee or Warranty of any kind,which the equipment will continue to retain the same percentage of accuracy or efficiency as determined on the date
when the calibration was performed by Williams. Operation,damage,or loss sustained by all parties arising or resulting from deterioration,obsolescence,malfunction,or substandard
performance of said equipment(s)shall be and remain the sate responsibility of the equipment(s)user,renter,and/or owner.This document shall not be reproduced except in full,
without written approval of Williams Form Engineering Co. RHT 08/10/12