Loading...
HomeMy WebLinkAboutDRB18-0576_Approved Plans_1543961490.pdf X40(1 CIF kd lS .7, C WERNERtk DRB APPROVED 12/4/2018 12:00:00 AM 1454 GREENHILL COURT, SUBDIVISION : GLEN LYON , LOT I E5 VAIL, COCOLORADO 81657 MATERIAL SYMBOLS: ABBREVIATIONS: GENERAL NOTES: DRAWING INDEX: GENERAL AND SITE N o , , , , , , „ A0.00 COVER N II iii IIIEARTH Com= PLYWOOD ABV ABOVE L LENGTH 01 DO NOT SCALE DRAWINGS TOPOGRAPHIC SURVEY ,..- AFFNr ABOVE FINISHED FLOOR LDT LIGHT AND DRAPERY TROUGH N. AP ACCESS PANEL LT LIGHT TROUGH °' L F—W—W— AC ACOUSTICAL LTL LINTEL 02 VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON X1 .01 ARCHITECTURAL SITE AND LANDSCAPE PLAN-EXISTING 0 �o�o�o POROUS FILL/DRAINAGE FINISH WOOD THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING p 1�������4 ADD ADDENDUM LVR LOUVER ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR A1 .01 ARCHITECTURAL SITE AND LANDSCAPE PLAN-PROPOSED ADJ ADJACENT MH MANHOLE E ALT ALTERNATE MFR MANUFACTURE (ER) DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. Iii/ %// ii/i STONE MASONRY WOOD-ROUGH ALUM ALUMINUM MO MASONRY OPENING 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY a /////////// ARCH ARCHITECT (URAL) MIL METAL RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE BSMT BASEMENT MAX MAXIMUM CONTINUES IN THOSE AREAS. DRAWING INDEX: ARCHITECTURAL '_ BRG BEARING MECH MECHANIC (AL) L <1 X2.01 LOWER LEVEL STRUCTURAL CONCRETE BLOCKING BVL BEVELED MC MEDICINE CABINET 04 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE, '' 1— BIT BITUMINUOUS MEM MEMBRANE UNLESS OTHERWISE NOTED.SECTION AND ELEVATION DIMENSIONS ARE PLAN-EXISTING y p BLK BLOCK M METER (S) TO TOP OF CONCRETE,TOP OF PLYWOOD, OR TOP OF WALL PLATES OR X2.02 MAIN LEVEL PLAN-EXISTING 41111C III o BLKGBLOCKING MM MILLIMETER (S) BEAMS UNLESS OTHERWISE NOTED. CONCRETE MASONRY UNIT GYPSUM BOARD BOT BOTTOM MIN MINIMUM A2.01 LOWER LEVEL PLAN-PROPOSED H BLDG BUILDING MIR MIRROR 05 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. CPT CARPET (ED) MISC MISCELLANEOUS LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL A2.02 MAIN LEVEL PLAN-PROPOSED 0 v o N Q X � CSMT CASEMENT MULL MULLION MOUNTED FIXTURES,TOILETS, TOILET ACCESSORIES, CABINETRY, w N U BATT INSULATION C CAULK (ING) NAT NATURAL COUNTERTOPS,SHELVES AND CLOSET RODS. A3.01 BUILDING ELEVATION-DEMO AND PROPOSED } CLG CEILING NR NOISE REDUCTION * 7 CT CERAMIC TILE NOM NOMINAL 06 O DENOTES DOORS. REFER TO FLOOR PLANS FOR LOCATIONS. REFER A3.02 BUILDING ELEVATION-DEMO AND PROPOSED CLR CLEAR NIC NOT IN CONTRACT 10111001110111 TO DOOR SCHEDULE FOR DOOR TYPES. I.Ill..11l.11i RIGID INSULATION COD CARBON MONOXIDE DETECTOR NTS NOT TO SCALE A3.03 BUILDING ELEVATION-DEMO AND PROPOSED ............. COL COLUMN OPG OPENING 07 0 DENOTES WINDOWS. REFER TO WINDOWS AND FLOOR PLANS FOR CONC CONCRETE OPP OPPOSITE LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. A3.04 BUILDING ELEVATION-DEMO AND PROPOSED // I STEEL/METAL AS NOTED CMU CONCRETE MASONRY UNIT OPH OPPOSITE HAND A6.01 EXTERIOR DETAILS / CONST CONSTRUCTION OH OVERHEAD CONT CONTINUOUS PR PAIR 08 COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT CJT CONTROL JOINT PK PARKING WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH CPR COPPER PVMT PAVEMENT ARCHITECT. DRAWING INDEX: ELECTRICAL AND LIGHTING IIIIIIIIIIIIIIIIIIIIIIIIIIII CARPET CUST CUSTOM PL PLASTIC LAMINATE iii Ill DT DRAPERY TROUGH PT POINT 09 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY XE2.01 LOWER LEVEL ELECTRICAL PLAN-EXISTING DTL DETAIL PSF POUNDS PER SQUARE FOOT THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS DIM DIMENSION PSI POUNDS PER SQUARE INCH PROJECT,HETHE CONTRACTOR SHALL IMMEDIATELY OF NOTIFY THE XE2.02 MAIN LEVEL ELECTRICAL PLAN-EXISTING DR DOOR PL PROPERTY LINE DRW DRAWING QT QUARRY TILE ARCHITECT. E2.01 LOWER LEVEL ELECTRICAL PLAN-PROPOSED DF DRINKING FOUNTAIN REF REFERENCE 1 1 ELEC ELECTRIC (AL) REF REFRIGERATOR E2.02 MAIN LEVEL ELECTRICAL PLAN-PROPOSED EL ELEVATION (S) REIN REINFORCE (D), (ING) 10 THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL A4.00 A4.00 APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED ELEV ELEVATOR REQ REQUIRED EQ EQUAL RES RESILIENT APPROVALS.THIS PROJECT IS GOVERNED BY THE INTERNATIONAL EXH EXHAUST REV REVISION (D), (ING) BUILDING CODE. CODE COMPLIANCE IS MANDATORY.THE BUILDING SECTION REFERENCE ELEVATION REFERENCE EXTG EXISTING REV REVERSE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES EXT EXTERIOR RH RIGHT HAND NOT CONFORM TO ALL RELEVANT CODES INCLUDING IBC AND ALL OQ FOC FACE OF CONCRETE R RISER LOCAL AND REGIONAL CODES. ILI FOF FACE OF FINISH R&S ROD AND SHELF Q FOM FACE OF MASONRY RD ROOF DRAIN 11 THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN W 0 CC 1 ( 1 1 FOS FACE OF STUDS RDT RECESSED DRAPERY TRACK APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY r 0 FIN FINISH (ED) RFG ROOFING CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE A4.00 A4.00 J `.." FFE FINISHED FLOOR ELEVATION RM ROOM CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS Im 0 O FE FIRE EXTINGUISHER RO ROUGH OPENING WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. 0 DETAIL REFERENCE DETAIL REFERENCE FDC FIRE DEPARTMENT CONNECTION R/S ROUGH SAWN .1 ILI o FHC FIRE HOSE CONNECTION S SEALANT (EXTERIOR) FEC FIRE EXTINGUISHER CABINET SHTG SHEATHING " Q FP FIREPLACE SHH SHOWER HEAD 12 THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE Z MAIN 1 FPS FIREPROOFING, SPRAYED SHC SHOWER CONTROLS OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT 0 Q iht100'0" A4.00 FLG FLASHING SM SHEET METAL APPROVAL PRIOR TO BEGINNING ANY SITE WORK. > `/ FLR FLOOR (ING) SIM SIMILAR y FD FLOOR DRAIN SC SOLID CORE 13 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE HEIGHT REFERENCE FTG FOOTING SPEC SPECIFICATION (S) CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, la ic2 SECTION REFERENCE FND FOUNDATION SQ SQUARE MATERIALS, TRANSPORTATION,SUPPLIES, EQUIPMENT, ETC.TO OBTAIN Q FBO FURNISHED BY OTHERS STD STANDARD A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE 12C 0 FPHB FREEZE PROOF HOSE BIB ST STAIN INDUSTRY. m FUR FURRED (ING) STL STEEL 00 ROOM NAME GA GAGE, GAUGE SD STORM DRAIN 14 ALL BUILDINGS TO FIT WITHIN PROPERTY LINES WITHOUT CROSSING Cl) CIC GALV GALVANIZED STR STRUCTURAL EASEMENTS OR SETBACKS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. J A GC GENERAL CONTRACT (OR) TEL TELEPHONE GL GLASS, GLAZING TV TELEVISION ILI E REVISION REFERENCE ROOM NAME GYP GYPSUM BOARD THR THRESHOLD 15 PROVIDE ACCESS PANEL TO MOTOR FOR ALL WHIRLPOOL-TYPE TUBS. O HB HOSE BIB T&G TONGUE AND GROOVE COORDINATE ACCESS LOCATIONS WITH INTERIOR DESIGNER AND > Z HDW HARDWARE TOS TOP OF SLAB ARCHITECT TO PROVIDE INCONSPICUOUS LOCATION. J HDR HEADER TOS TOP OF STEEL ILI HTG HEATING TOW TOP OF WALL Z W GRID W11 I HVAC HEATING/VENTILATING/AC TB TOWEL BAR CC HT HEIGHTTR TRANSOM PROJECT SUMMARY: HC HOLLOW CORE T TREADDti HM HOLLOW METAL TYP TYPICALII GRID BUBBLE WALL TYPE REFERENCE HOR HORIZONTAL UNO UNLESS NOTED OTHERWISE Code: 1141 HWH HOT WATER HEATER VB VAPOR BARRIER International Residential Code 2015 1 INCL INCLUDE (D), (ING) VIF VERIFY IN FIELD Occupancy: Two-Family Dwelling, R-3 ID INSIDE DIAMETER VERT VERTICAL railings , 4 A8.1 2 IBC INSTALLED BY CONTRACTOR VCT VINYL COMPOSITION C WATER CLOSET Separations: 1 Hour (residence/garage) IBM INSTALLED BY OWNER WP WATER PROMING 1 Hour (residence/mechanical) INS INSULATE (D), (ION) 3 INT INTERIOR WWF WELDED WIRE FABRIC JC JANITOR'S CLOSET W WIDTH, WIDE W I OW S , INTERIOR ELEVATION REFERENCE WINDOW TAG KIT KITCHEN WDW WINDOW ISSUED FOR: DATE: LAM LAMINATE (D) WO WITHOUT LAV LAVATORY WD WOOD stucco etc TOV ORB FINAL REVIEW 11.19.18 LH LEFT HAND ® STN--/---TILE DOOR TAG MATERIAL BREAK shall match - COPY RIGHT RESERVATION existI� nO cr The drawings, specifications and other documents prepared by the Architect (Michael Suman Architect, LLC) for this project are instruments of the Architect's service for use solely with respect to this Project and, unless otherwise provided in writing, the Architect shall be deemed the sole and exclusive author of these documents and shall retain,without limitation, all common law, statutory and other reversed rights, includingthecopyright hereof. Noperson, whether © MICHAEL SUMAN ARCHITECT,LLC. copy g ALL ALL RIGHTS RESERVED. having come rightly into possession hereof or otherwise, shall employ these documents on any other project, nor SCALE: for additions to this Project nor for the completion of this DRAWN: MDS ARCHITECT- . Project by others, unless with the prior express written consent of the Architect and upon appropriate SUMAN ARCHITECTS compensation to the Architect in an amount and kind PROJECT#: 1809 P.O. BOX 7760 satisfactory to the Architect. The Architect expressly SHEET TITLE: COVER SHEET AVON, CO 81620 claims all proprietary rights in the material which is issued 970.479.7502 in confidence for design and/or construction purposes of CONTACT: MICHAEL SUMAN this Project as noted. These materials may not be EMAIL: michael@sumanarchitects.com copied, modified, nor employed in any way without the specific prior written consent and permission of the Architect. AOIOO ©2018 Michael Suman Architect, LLC. All rights reserved.