HomeMy WebLinkAboutDRB18-0586_Approved Plans_1543961474.pdf z
ec
130tip
')-1410)1115
DRB
APPROVED
12/4/2018
12:00:00 AM
o
To
■
wo
ADDITIONAL NEW BUILT-IN TO MATCH TRIM
TUB SPOUT IN NEW ELECTRIC NEW ELECTRIC PACKAGE MATERIAL AND FINISH ! ■
1 PROPOSED P LAN SHOWER CONDUIT RISER FROM BELOW. CONDUIT RISER FROM BELOW.
ROUTE TO NEW PANEL ROUTE TO EXISTING PENETRATION GLASS SHOWER ALIGN FIXTURE0 °
A2.01 SCALE: 1/4" = 1-0" (206) LOCATION THIS UNIT. ABOVE FOR UNIT ABOVE. (201) ENCLOSURE WITH ON CENTER OF ,
MECH. CONTROL RE:STRUCTURE FOR RE:STRUCTURE FOR BARNDOOR SLIDING TUB NEW MEDICINE CEILING CilL •
CPT 210x 6 ON WALL CPT 3°x 6s HARDWARE ACCESS PANEL
PLAN NORTH PENETRATION PENETRATION CABINET
.1.
GENERAL NOTES: � . QIZ ��� CUBBIES I , MASTER
1. CONTRACTOR TO VERIFY ALL EXISTING WALL LOCATIONS, WALL/FLOOR/ROOF CPT �' 4 -dI I
Pa Pa if Pr al _ 36" REF. O m N ■ OR I �) BATH
SYSTEMS,AND MECHANICAL/ELECTRICAL SERVICE LOCATIONS AND ROUTING. L rii G"vai G"+ INTEGRATED U IN CABINET J 215
2. SMOKE DETECTORS TO BE INTERCONNECTED PER IBC CODE-HARDWIRE ZO - WASHER DRYER ___ `O '
3. CARBON MONOXIDE DETECTORS TO BE INSTALLED PER IBC OWNERS GUEST NEW WOOD ripM _ > OWNER S
4. EXISTING FIRE ALARM SYSTEMS TO REMAIN. REQUIRED MODIFICATIONS TO BE - ~O 3' 33/4' CLOSET
CLOSET BATH oo a . ° ACCENT WALL KITCHEN STN – 3 Qa -n 303/4' L J 2146
ENGINEERED BY BUILDING SUB-CONTRACTORS AND APPROVED BY FIRE NEW MEDICINE 206 205 N —STORAGE — _ BATHO I I }
DEPARTMENT PRIOR TO INSTALLATION CABINET LAUNDR�204� TO MATCH 203 - o 0 LLo I
ENTRY BUILT-IN M E T .Y w o ONE
5. DO NOT SCALE DRAWINGS, IF DIMENSIONS ARE IN CONFLICT OR DO NOT APPEAR • 204 n LIRLL
�__J
v • 2p� 5'-0" 2sx 6s .01 z o 216 ® BENCH I
ON THE DRAWINGS, NOTIFY ARCHITECT. - w r
.21 RELOCATED _, I (214
6. ALL PLAN DIMENSIONS LOCATING PARTITIONS ARE TO FACE OF STUD OR -r 12"SHELVES O 216 a s
CONCRETE WALL FACE, U.N.O. 68 w "' ELECTRICAL 36" D.W. • Q 2 x 68._//,'
- o a
N z + o RENTER'S
7. FINISH DIMENSIONS ARE TO THE FINISH FACE AND NOTES"FIN"OR"CLR". 7 O m 1 ° PANEL BELOW CUBBIES 26 x 6s I I I I
2 x b
CLOSET
c� 0 a L-� o -_- oL 214A
8. CONTRACTOR TO REVIEW NEW ELECTRICAL PANEL, OUTLET,AND SWITCH GUESTo TILE BUILT-IN DESK N OR TILEI I
N 1 F42" SITTING W/ 115 STORAGE 7 S N CABINET -�
LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN AND DRYWALL INSTALLATION. CLOSET - �
9. REFER TO ELECTRICAL, LIGHTING AND LOW VOLTAGE DRAWINGS FOR 0 207 205 W I H OPEN LEG SPACE co- r� BELOW . I' IM k,
2-4 CPT CPT WD RELOCATED • '1\ Wp WD I CPT CPT (214A)
10. COORDINATE BLOCKING FOR BATH HARDWARE WITH INTERIOR ELEVATIONS AND M 26 x b$ ROUTE DRAINS WD
CONTRACTOR. 208) MECH. VENT TO EXISTING WD (213A) \ ELECTRIC 2°x 68 �•�
15. CONTRACTOR TO IDENTIFY GLAZING HAZARDOUS LOCATIONS AND PROVIDE LOW IN WALL o .0 6 s PANEL Ir
FLOOR NEW FAUX 2 x 6
SAFETY GLAZING PER IRC. _ 26 x 6s NEW FAUX in LOCATION TIMBER
16. ALL EXISTING INTERIOR TRIM, INTERIOR DOORS, AND WINDOW FRAMES TO BE LIMITS OF TIMBER COLUMN
b COLUMN
PAINTED. LIVING SEATING ICP"
ILI
17. NEW PAINT AND STAIN FINISHES THROUGHOUT ,
, _1 . 40'TALL BOOKCASE ONE (212A) J
5'-�4. A 1 z w r • CI)
WT C rA Z ‘41111!
il� 211A 26x6sTWIN O `O 1-
N o s (211 B)
OVER • ^• m 4 x 6 _
PARTITION LEGEND:
QUEEN 5'-0"
BUNK \ 2°x 68
//////////////////////////. NEW WALL CONSTRUCTION z o NEW BUILT-INS
0 v
I I EXISTING WALL CONSTRUCTION TO MATCH TRIM
LIVING b PACKAGE Oc w
r NEW STONE VENEER BEDROOM GUEST Ss AIR ROOM ROOM r," 7; Q MASTER S BEDROOM
208 209210 �/ 213Lig (1) ■.
Ox N 7 m m
NEW BUILT-IN BUNK NEW BUILT-IN z ml
BEDS TO MATCH TRIM TWIN TO MATCH TRIM J BEDROOM OWNER SUPPLIED
OVER PACKAGE
EQUEEN la rtt
m PANELINGWOODWALL FROM
• CC
AND FINISH BUNK ` 212 ARRIGONI STORAGE
MI
PACKAGE MATERIAL ONE
NEW RAISED , 1-
(",) CRADLE STONE HEARTH3 .
- -
C �s NEW BUILT IN BANQUET Q
T NEW FURRED OUT 44 Z4)
la CC CC
\ 1,,p %, RAISED GAS 4 TO MATCH TRIM 0
N t \-,<,AC . SHUTOFF v PACKAGE MATERIAL
GAS ��WALL F.P.SURROUND
BASE BOARD HEATS: AND FINISH SHUTOFF WITH STONE HEARTHla 0 4
BASE BOARD HEATER \ ` _ AND WOOD MANTLE
❑ m rl _ I I I I • I I ] _ EXISTING _ A g
EXT R102 CARLE (909) �i NEW SLIDING DOORS I
(212B� (213�) GAS F.P.
OiCNI
EXPOSED WITH SCREENS-TYP. EX-ERIOR GAS STUB N
EXPOSEB 59x 6? �6? 5 9 x 6; CABLE 59x 68 ›.
GAS STEX'CSED
EXTERIOR I I EXTERIOR 1
4
Db 'K A DECK BIM
217A I 11178
-RAISE HEIGHT OF NEW
OPENINGS AS HIGH AS
EXISTING STRUCTURE ALLOWS.
VERIFY IN FIELD PRIOR TO
Door height will be more ORDERING NEW DOOR UNITS- ISSUED FOR:
consistent with 1st floor. See email TYP. PROGRESS DRAWINGS 11.20.18
dated 12/4/2018
RAISE HEIGHT OF NEW
OPENINGS AS HIGH AS
2 PROPOSED ELEVATION - EXISTING STRUCTURE ALLOWS.
HIDE EXPOSED CABLE, VERIFY IN FIELD PRIOR TO HIDE EXPOSED CABLE,
A2.01 SCALE: 1/4" = 1'-Q"
PROVIDE ACCESS TO ORDERING NEW DOOR UNITS- PROVIDE ACCESS TO
CABLE JUNCTIONS TYP. CABLE JUNCTIONS r
1
1
- LI Li u L
_ .___1 L 2017 MICHAEL SUMAN ARCHITECT,LLC.o
a
1- w
DRAWN:
H- 1-
1 0
-
10
0 =
LAN
Areay 209 = Z (212B) � _ •• -
X (210 (213BB �����
9 a Q w 9 z 9 9 2
t,1
.®i t A =- 101014410- 711. da el 5 x6 5 x6' 5 x 6 5 x 6 t
1 1 Mal 1619*M.1 [.1 ,1 I i Opal a II I I ea
REPAIR AND REPAINT \ NEW SLIDING DOORS
-kiar - A201
WALL AT RAILING WITH SCREENS, NEW 1
NEW WINDOW, MATCH ATTACHMENT DOOR TRIM TO MATCH
EXISTING WINDOW AND LOCATION EXISTING-TYP.
TRIM
ciltticiFi.04,
iti.
vo
S C
DRB
APPROVED
12/4/2018
12:00:00 AM
N E
^o U
n []
ri
1 DEMO PLAN � '
� s
L
D2.01 SCALE: 1/4" = 1'-0"
o0
E
PLAN NORTH
(�N
V
DEMOLITION NOTES: o
1. CONTRACTOR TO COORDINATE ALL WORK WITH THE TOWN OF VAIL c
2. REMOVE ALL EXISTING FURNITURE PRIOR TO STARTING DEMOLITION
3. PROCEED WITH CAUTION IN DEMOLISHING ANY EXISTING WALLS- REMOVE
DRYWALL AND ANY OTHER FINISHES PRIOR TO REMOVING FRAMING. NOTIFY F -
ARCHITECT AND ENGINEERS AS SOON AS WALLS, CEILINGS, AND FLOORu
STRUCTURE HAVE BEEN EXPOSED FOR REVIEW OF EXISTING CONDITIONS. REMOVE EXISTING CABINETS, 44c)
4. CONTRACTOR TO NOTIFY ARCHITECT IF MECH, PLUMBING OR ELECTRICAL APPLIANCES AND MINIMIZErz
ADDITIONAL o
COMPONENTS ARE EXPOSED SO COMPONENTS CAN BE PROPERLY TUB SPOUT IN CHASE AREA BEHIND DRYWALL o _Na
RE-ENGINEERED OR RE-ROUTED AS NECESSARY. co
SHOWER
5. ALL EXISTING BASEBOARD HEAT SURROUNDS TO BE REMOVED AND PREPARED FOR CEILING 0 6N - Q
NEW WOOD TRIM SURROUND DESIGN ACCESS PANEL REMOVE END CHASE MIXING VALUE +v LU N U
WALL BAY THAT AND SHOWER iii A
6. SEE REFLECTED CEILING DEMO PLAN FOR ADDITIONAL DEMOLITION SCOPE. MECH. CONTROLDOESN'T CONTAIN HEAD IS OFF CEILING �I7
7. ALL EXISTING DOORS TO BE REMOVED AND OPENINGS REFRAMED FOR ARCHED
TOP DOOR OPENINGS.
CPT ON WALL PIPES CENTER OF TUB ACCESS PANEL
/ ilkL 11 ,
♦
Ailli-
M r WALL
i 1-P- -7
___ 1-- -,/
CPT% / w Irma,' N L1J ♦ ♦ / II + .r• BATH III I ACCESS
PARTITION LEGEND: L J Q I---- 1"�l ----I II III N I LL____JJ L• 215 II I III IPANELL
RE . �I I ,� I I III I �"
1 I EXISTING WALL CONSTRUCTION OWNERS GUEST
1 L--- itis- L� II I I
CLOSET BATH C E �� O; • • ; I I I LII
___ 2 6 205 STORAGE BATH II
---� DEMO EXISTING ° _ LAUNDRY ,/' REMOVE EXISTING TILE _ __ I 0 s RELOCATE HUMIDIFIATION
FLOOR FINISH AND PREP. ENTRY ONE I ve—_ CONTROL ON WALL
n 204 0 KITCHEN FOR NEW FINISHES 201 216 I I—_--
11E.
r-- THROUGHOUT r-- r11 � �
= If, ---- - If ,1 1• II ^�1I I CLOSET
I. .1 .1_
Tr_1 II •1 L>JI �, I I g I 214
---- TILE` ILJ ���� --- r 1 • TIL��► I`J I TILE \ I
----
I I `__— L_J Iftr IP v \ •` i
__ _ _ �►
/
__ __ --_
++ CPT SD SD/ , �_ CPT \ OSDI\
CPT
IP RELOCATE ELECTRIC RELOCATE ELECTRIC I ELECTRIC PANEL
RELOCATE CONDUIT FROM BELOW CONDUIT FROM BELOW
MECH. VENT ____ I�SOFFIT ABOVE
TO NEW PANEL LOCATION TO NEW LOCATION I _
IN WALL BEHIND KITCHEN � � 7'' W
I� .+ r
CABINETS. ^ ,
1 0
r + ^ i ` REMOVE SECTION OF
CLOSET CLOSET I BASEBOARD HEAT TO 0 Z
ONE A ONE B MAKE ROOM FOR M la 0
211A 211B CRADLE BED N
gni cil0
GUEST LIVING DINING Z
BEDROOM MASTER J
BEDROOM ROOM ROOM ONE BEDROOM0
W (1)
V
208 209 210 212 213 )ii
CC
CI
>
REMOVE EXISTING
\ c IZ z
BASEBOARD AND PREP mi
\ \\ REMOVE TILE W I-
FOR NEW LOCATION
ALONG EAST WALL /
\( \ \
CC 0
C \ RAISE EXISTING GAS v REMOVE F.P. a
H
\ ) FIREPLACE FOR
\ SHUTOFF STONE W0
L Ne 00 ` RAISED HEARTH BASE BOARDHEATE-, —J J _11 SURROUND 3 j
-I 5
l_il:1—[0—L-1 \ i
—EXTERIOR CABLE
II EXPOSED I EXTERIOR i II
W
I CABLE
I EXPOSED W
EXTERIOR 1' REMOVE GUARDRAIL EXTERIOR
DECK A I SECTION. DECK B
IM
217A I 217B
ill I
ISSUED FOR: DATE:
PROGRESS DRAWINGS 11.20.18
CD-2-
DEMO ELEVATION -
2.00:) SCALE: 1/4" = 1'-0" _
L G. 2017 MICHAEL SUMAN ARCHITECT,LLC.
_, ,._. 1,
ALL RIGHTS RESERVED.
IF
-,r-, 11 111 11 11 111 11 11 111 m__
11 11 111 11 SCALE: 1/4"=1'0"
II III II
II III II DRAWN: MDS
II III II
srTrip _ - I - I
lAirk A __ n f -' -- PROJECT#: 1707
II _I SHEET TITLE: FLOOR PLAN
4
4 co -034 fir
frit
I I
LIL--J L---I L--J II IL--1L-- L__J1L__JI ii. tif A II
vg0Au-s* rfrift&ii
_ REMOVE GUARDRAIL REMOVE EXISTINGo . ■ 0 1
DOOR AND •
REMOVE EXISTING BLOCKING
WINDOW
z
9-40 4175
0
DRB
APPROVED
12/4/2018
12:00:00 AM
RI E
Nr 6
0 7g
o
Tu
o
o
■
ADDITIONAL WASHER
TUB SPOUT IN HOOKUPS r 71)5 Lti3N
L3
1 EXISTING PLAN SHOWER
CEILING MIXING VALUE D • U
X2.01 SCALE: 1/4" = 1'-0" (206) ACCESS PANEL ENTRY 201 AND SHOWERCC
MECH. CONTROL CLOSET HEAD IS OFF CEILING 1 •
CPT 210 68 ON WALL 202 CPT 3°x 68
PLAN NORTH CENTER OF TUB ACCESS PANEL
_ i„ h—�1 i,__, ,�� t 1 II
I 1-, 4 • .....
CPT b I— w w X202\� TIL �' fa I= M BATH WALL
I ACCESS
c) L _1 (T, - - - - O�O- - - - - 6 a` c� N .� 215 I PANEL LOW
032"REF. I2 x6 1I
OWNERS GUEST r- 3 - �O O s/2'J • - 4' 11"M s' to/2 - I I6 0
�'L STOR 1E t 9'-8a" 1 1 3' 0" 1 2' 7Y�' 1 = C1:9C.E _CLOSET BATH Op,� L J
206 205 , IR o BATH o _ MECH. b
LAUNDIRY 20 o ENTRY
'� 204 KITCHEN o - ONE ® CONTROL
I 3°x168 203 v 201 216 ® ON WALL
4'-23/4" 5' 6Y4" _ 5' 3"1 3' 4/a" 12'-8" 7'-1%a"
- - - (216) 24x 68 _ 111 I. „ MASTER-n L — - �-� , . , • CLOSET
.--T 1 I - - TILE 6 8 I I
�� o J 3 0 2 x 6 . - 214
TILE / I _ I 1 f TILE o• TILE \\
r J o m_, L__°-J cel TILE �� N `\ �►
CP 205 SD/r -1 SCpFFIT r Sp M 1 FFI1�AiBOV� \ CPT C213A0-1 � • 3' %2' CPT (214)
ABOVE � CPT , i � i^�
i 2 x 6 MECH.VENT N k`Sp 26 x 68 t..../
SD ELECTRIC PANEL ADDITIONAL 2°x 68
207 6 8 -ELECTRI -SOFFIT AND WALL
GUEST IN WALL PANEL I OFF Elf FROM SOFFIT ABOVE TUB
3°x 68 CLOSET (208 BEDROOM WALLS SHOWER IN
207 M = DILI
26x 8 i - - -
Mic",r-..-.-
C212A) CI)-
2 6 x 68
I CLOSE CLOSET (116) _
ONE A ONE B 8 •
4°x6' 211A 211B 2 x6N w 0
=,,
<:.,, c. 1- 0 ;It
v r LL v z .
GUEST o
c,i LIVING DINING BEDROOM = = MASTEI b
BEDROOM ROOM ROOM ONE a < BEDROOM •
208 209 210 212 LL LY, 213 > (fi ().,
I CC ml
_ 10'-2k4" 24'-113/4" - 11'-6/4' 12'-10Y20 la rg
1 - - - -
4'-0„ 1 3 0 l
Li
YIICAL CENTER ITE T V.I.F. T • CC 4
& \ BE WEEN CONCRETE"T'
TILE FIREPLACE STV TURF,"T"SHAPE IS 5" w
HE?1RTH WID CEILING,4"WIDE AT w '
BOTTOM, 10"HIGH, WOOD Q CC •
\ SHUTOFF FIN SH DIM. 6 2 W x 12 2' H GAS
\ IBASE BOARDHEf.TEf� SHUTOFF
1.111 0
NI
' N I- I I TJ
;,) .— c4 A ;
EXTERIOR CABLE (209) 210
• 4' 0" o EXPOSED EXTERIOR GAS STUB ›.
`� GAS STUB 59x 68 59 x 68 59 x b81 CABLE 59 x 68 FIREPLAC
E OSED INTAKE VEN11 q C
l'-107/8"
[PRECAST RAILING EXTERIOR 5 2"WIDE DECORATIVE EXTERIOR PCAST RAILING
DECK CAP AT DECK A WOOD RAILING WITH DECK B DECK CAP AT • IM
EACH END 217A 8"x8"NEWELL POSTS
- _21713
EACH ENDS
J •
1'-3%2" 3Y2" 11Y2" 8/2' 6"
2'-3%a" 4'-5Y2" 3'-1Y4" 4'-3" 11%2" 6'-1" 4'-7" 6'-1" 4'-7" 6'-1" 4'-7" 6'-1" 4'-8" ' •' DA
T- . .. . . . . . . .
PROGRESS DRAWINGS 11.20.18
9'-10" 5'-10" 10" 20'-0" 25'-4/2'
6"
36'-0"
2 EXISTING ELEVATION \r— -
X2.01 SCALE: 1/4" = 1'-0"
r
DRAWN: MDS
-
1_1 ,i1.44%„,y _ _..._ _..._ _1 _..._ _..._ vedkroge , PROJECT#: 1707
SHEET TITLE: FLOOR PLAN
11AIIP r• iipieveil
k- .4*---10,- Ap-: Ito-... "Pot. -.
.4Philt
\ --41411°4411
,114110111ridi
X2 0 /
5 2'WIDE DECORATIVE EXISTING SLIDING - VNratil IL
_ -1-kil*wirestriii '
WOOD RAILING WITH DOOR if
EXISTING WINDOW 8"x8"NEWELL POSTS