Loading...
HomeMy WebLinkAboutApproved Plans_9.pdfCurrent Lighting layout 0 ', ~ e e I e I Current recessed light ~ ~ rll • Current overhead light/fan +0 e rll I Current wall light or 0 sconce I .. I ~,. I . -. -I , I 11 Town of Vall OFFICE COPY ~ Rt.Ct.\\/£.0 ~r)R 2o1G\S \o'l'ln oi \Ja\\ \l ~ ......... C)) • \)o ~ __, ~ ~~ . " '\ . Y. .. ' VI "'O Q) c '-ro o . '-..0 Q) Q) ..... ro VI 3: ro ..0 ..... ..... VI c c '-Q) Q) Q) '-'-..... '-'-ro :;, :;, Q) u u ..c. 0 GJ 0 ~ [;] ~ 8 ~ :;, 0 > ro 0 tl.O [;] c :0 E .. :;, a.. ..... c Q) '-'-:;, u • New Plumbing Layout [iJ ~ --·-·---, I New water line G ~ fl"'tf'h J New gas line J tit I Removed water line I 13 r.. I Removed I --h: I 1 baseboard heater ~ 0 ,. 9 ,.? rown of Vail · RE~IEWED FOR CODE c9MPLIANCE Da~e:_-"'-~-------1 By:' .... I Code: --'-~----, • . .., ' ,-.,.-·· \ -"\ New Lighting layout. a ~ 0 6 8 EJ 0 ~ 0 ~ ~ 0 [§)0 e0 I I I. -----·· --New recessed lights I· """ I ~ -..._, e 4 0 ~ ~ L7a I 6 e I ~7'~ I New ceiling light/fan ~ I I Removed recessed I I e light EJ ~ • Removed ceiling light or fan ..... New wall light I e I, ~ ... ' .J~J ~ sconce 13 /j Current Electrical Layout .. ~ R ~ , .. I A I ... ,.. I ..... I 00 0 0 30 I~ ~ 0 ~ D D " D 0 ~ DI Current Electric outlet ! I Current light switch I I Current dedicated ~ appliance switch. Stove/range, refrigerator, dishwasher. & clothes washer and dryer ,-J? I I ~ 1 d ~ -.......... 0 J ~ ~ ~ • New Electrical Layout ~G ~ ~ 20a I ~ A ---, I L •., I A f~~~ fov--'f<XJ CFM I 20 I 21 I 0 &r 4recth:r ~.x,i ~~~ ~~(__ Ma.~ o..~r. • • I ""\r-I I I _J D 0 ~ ~ 0 D It 0 D 0 0 I 24b I 24a [__ I 24 ~ 0 D D l-New Electric outlet I ! I New light switch I I I New dedicated appliance switch. Stovetop, & clothes washer and drver ! I Removed light switch I D I Removed outlet I 4 I -~-·~ 1Town of Vail !REVIEWED FOR CODE 1COMPLIANCE I • Date: .J • , ,. __ _ lsy: , .-Code: 1< I. ~ , . ' Current Plumbing/Gas Description: 1 MB Bath Sink 2 MB Bath Toilet 3 MB Bath Tub 4 Guest Bath Tub 5 Guest Bath Toilet 6 Guest Bath Sink 7 Washer Water connection 8 Kitchen Sink 9 MB floor heat (gas) 10 MB Bath floor heat (gas) 11 Guest BR floor heat (gas) 12 Guest Bath floor heat (gas) 13 Living RM Floor heat 1 (gas) 14 Living RM floor heat 2 (gas) 15 Kitchen Floor heat 1 (gas) ~ ~ .......... C) ~ .... 8(£> • New Plumbing/Gas Description: ' 1 MB Bath Sink 2 MB Bath Toilet 3 MB Bath Tub 4 Guest Bath Tub 5 Guest Bath Toilet 6 Guest Bath Sink 7 Washer Water connection (relocated) Washer Water connection (new 7a location) 8 Kitchen Sink (relocated) Sa Kitchen Sink (new location) 9 MB floor heat (gas) 10 MB Bath floor heat (gas) 11 Guest BR floor heat (gas) 12 Guest Bath floor heat (gas) 13 Living RM Floor heat 1 (gas) 13a Gas line for gas fireplace (new) 14 Living RM floor heat 2 (gas) 15 Kitchen Floor heat 1 (gas) 16 Kitchen Floor heat 2 (gas) (new) 10 "" 1 Current Electrical Layout Description: 1 MB wall outlet 2 MB wall outlet 3 MB wall outlet 4 MB wall outlet 5 MB Light switch 6 MB wall outlet 7 MB Light switch 8 MB wall outlet 9 M Bath Light switch (mirror light and ceiling fan/light) 10 M Bath wall outlet Guest Bath light switch (mirror light and ceiling 11 fan/light) 12 Guest Bath wall outlet 13 Guest BR wall outlet 14 Guest BR wall outlet 15 Guest BR wall outlet 16 Guest BR wall outlet 17 Guest BR Light switch 18 Guest BR wall outlet 19 Hall light switch 20 Dryer Outlet (240V) (dedicated) 21 Washer Outlet (240V) (dedicated) 22 Living RM Light switch 1 23 Living RM wall outlet 24 Living RM wall outlet 25 Living RM Light switch 2 26 Living RM wall outlet 27 Living RM wall outlet 28 Front Porch Light Switch 29 Dining RM Light Switch 30 Dining RM wall outlet 31 Dining RM wall outlet rl ~ ...... ~ j ~ ~ 2 .. ~ 32 Dining RM wall outlet 33 Kitchen Light Switch 34 Refrigerator Outlet (dedicated) 35 Kitchen Wall outlet 36 Dishwasher Outlet (dedicated) 37 Kitchen Wall outlet 38 Oven/Range Wall outlet (dedicated) 39 Exhaust Fan/Light outlet (dedicaated) 40 Kitchen Wall outlet 3 .I Current Lighting layout: Ll MB Bath wall light L2 MB Bath ceiling fan/light L3 Guest Bath ceiling fan/light L4 Guest Bath wall light LS Hall recessed light {100 watt) L6 Kitchen overhead light L7 Dining Rm overhead light LS Front porch light L9 Living Rm recessed light 1 (100 watt) LlO Living Rm recessed light 2 (100 watt) Lll Living Rm recessed light 3 (100 watt) \(( ~ ........ ? ~ '--AA 12 , ,, New Lighting Layout: Ll MB Bath wall light (removed) Lla MB Bath recessed light 1 (new) 9 watts Llb MB Bath recessed light 2 (new) 9 watts Llc MB Bath recessed light 3 (new) 9 watts Lld MB Bath recessed light 4 (new) 9 watts L2 MB Bath ceiling fan/light L3 Guest Bath ceiling fan/light L4 Guest Bath wall light LS Hall recessed light (100 watt) LG Kitchen overhead light (relocation) LGa Kitchen overheard light 1 (new location) L7 Dining Rm overhead light (relocation) L7a Dining Rm overhead light (new location) LS Front porch light L9 Living Rm recessed light 1 (9 watt) (new) -replaces 100 watt light LlO Living Rm recessed light 2 (9 watt) (new) -replaces 100 watt light Lll Living Rm recessed light 3 (9 watt) (new) -replaces 100 watt light L12 Ceiling Fan (new) L13 Living Rm recessed light 4 (9 watt) (new) L14 Living Rm recessed light 5 (9 watt) (new) LlS Living Rm recessed light 6 (9 watt) (new) LlG Living Rm recessed light 7 (9 watt) (new) L17 Living Rm recessed light 8 (9 watt) (new) L18 Living Rm recessed light 9 (9 watt) (new) L19 Living Rm recessed light 10 (9 watt) (new) L20 New Hall recessed light (9 watt) (new) L21 Guest BR overhead light (new) L22 MB recessed light 1 (9 watt) (new) L23 MB recessed light 2 (9 watt) (new) L24 MB wall sconce (new) L25 MB ceiling fan (new) 14 ( L26 MB recessed light 3 (9 watt) (new) L27 MB recessed light 4 (9 watt) (new) L28 MB wall sconce (new) 15 trical L t Descriof 1ur1; -.,,____ ·~ -~-_,.........-______......,-1 MB wall outlet la MB wall outlet (new) -2 MB wall outlet 3 MB wall outlet 3a MB wall outlet (new) recessed for wall mount TV 4 MB wall outlet 5 MB Light switch 6 MB wall outlet (removed) 7 MB Light switch (removed) 8 MB wall outlet 9 M Bath Light switch (mirror light and ceiling fan/light) M Bath Light switch (mirror light and ceiling fan/light) -9a (relocation) 9b Bathroom heated Floor controller (new location) 10 M Bath wall outlet (relocation) 10a M Bath wall outlet (move) 11 Guest Bath light switch (mirror light and ceiling fan/light) 12 Guest Bath wall outlet 13 Guest BR wall outlet 14 Guest BR wall outlet 15 Guest BR wall outlet 16 Guest BR wall outlet 17 Guest BR Light switch 18 Guest BR wall outlet ·~ \ . \ 18a Guest BR wall outlet (new) recessed for wall mount TV 19 Hall light switch (relocation) 19a Hall light switch (new location) 20 Dryer Outlet (240V) (dedicated) -(relocation) 20a Dryer Outlet (240V) (dedicated) -new location) 21 Washer Outlet (240V) -converted to regular wall outlet 22 Living RM Light switch 1 (removed) ~ --- New Electrical L t Description ~-·-~--~__..---.._....._-.. 1 MB wall outlet la MB wall outlet (new) 2 MB wall outlet 3 MB wall outlet 3a MB wall outlet (new) recessed for wall mount TV 4 MB wall outlet 5 MB Light switch 6 MB wall outlet (removed) 7 MB Light switch (removed) 8 MB wall outlet 9 M Bath Light switch (mirror light and ceiling fan/light) M Bath Light switch (mirror light and ceiling fan/light) -9a (relocation) 9b Bathroom heated Floor controller (new location) 10 M Bath wall outlet (relocation) lOa M Bath wall outlet (move) 11 Guest Bath light switch (mirror light and ceiling fan/light) 12 Guest Bath wall outlet 13 Guest BR wall outlet 14 Guest BR wall outlet 15 Guest BR wall outlet 16 Guest BR wall outlet 17 Guest BR Light switch 18 Guest BR wall outlet 18a Guest BR wall outlet (new) recessed for wall mount TV 19 Hall light switch (relocation) 19a Hall light switch (new location) 20 Dryer Outlet {240V) (dedicated) -(relocation) 20a Dryer Outlet {240V) (dedicated) -new location) 21 Washer Outlet {240V) -converted to regular wall outlet 22 Living RM Light switch 1 (removed) ci ~ 0 l be ~ p.o 5 J 23 Living RM wall outlet 24 Living RM wall outlet 24a Living RM wall outlet recessed for wall mounted TV (new) 24b Gas fireplace switch (new) 25 Living RM Light switch 2 26 Living RM wall outlet 27 Living RM wall outlet 28 Front Porch Light Switch 29 Dining RM Light Switch 30 Dining RM wall outlet 31 Dining RM wall outlet 32 Dining RM wall outlet (removed) 33 Kitchen Light Switch (removed) 34 Refrigerator Outlet (dedicated) 35 Kitchen Wall outlet 36 Dishwasher Outlet (dedicated) 37 Kitchen Wall outlet 38 Oven/Range Wall outlet (dedicated) 39 Exhaust Fan/Light outlet (dedicaated) 40 Kitchen Wall outlet . 6 \ As is Electrical Panel Configuration: Panel Number Description Panel Number Description 1 240v Main 100 amp 2 Blank 3 240v Main 100 amp 4 Blank 5 240v Range 50 amp 6 Garage door opener 120v 20 amp 7 240v Range 50 amp 8 Boiler 9 240v Dryer 30 amp 10 Refrigerator 120v 20 amp 11 240v Dryer 30 amp 12 Kitchen outlet I Garbage disposal 13 Living Room, Outside & Hallway lights 14 Dining room outlets 15 Kitchen & Dining Room lights 16 Kitchen Hood light & exhaust 17 Master Bedroom outlet & Bathroom 18 Dishwasher outlet/lights 19 East Bathroom outlet/lights 20 Blank 21 240v Garage 50 amp {for Dryer outlet) 22 Blank 23 240v Garage 50 amp {for Dryer outlet) 24 Blank Load Calculation for Remodel: Only addition is the #20 circuit. Panel Number Description Panel Number Description 1 240v Main 100 amp 2 Blank 3 240v Main 100 amp 4 Blank 5 240v Range 50 amp 6 Garage door opener 120v 20 amp 7 240v Range 50 amp 8 Boiler 9 240v Dryer 30 amp 10 Refrigerator 120v 20 amp 11 240v Dryer 30 amp 12 Kitchen outlet I Garbage disposal " ~ 13 Living Room, Outside & Hallway lights 14 Dining room outlets ...... 15 Kitchen & Dining Room lights 16 Kitchen Hood light & exhaust 17 Master Bedroom outlet & Bathroom 18 Dishwasher \) outlet/lights I 19 East Bathroom outlet/lights 20 Jetted Bathtub 21 240v Garage 50 amp {for Dryer outlet) 22 Blank 23 240v Garage 50 amp {for Dryer outlet) 24 Blank bo ........ ~ 19 I Information for Load Calculation of current state and remodel. Current Appliance Electrical Requirements (amp x volts= Watts) Appliance Amp Requirements Volts Watts Range/Oven 50 amp 240 volts 12,000 Fridge 20amp 115 volts 2,300 Fan 10 amp 120 volts 1,200 Washer I Dryer 30amp 240 volts 7,200 Dishwasher 15 amp 120 volts 1,800 Garage Door Opener 50 amp 120 volts 6,000 Garage Outlet (dryer) 20 amp 240 volts 4,800 Boiler Remodel Appliance Electrical Requirements: Significant power savings on new LED recessed lighting. Appliance Amp Requirements Volts Watts Induction cooktop 40amp 240 volts 9,600 Oven 20amp 240 volts 4,800 Fridge 20amp 115 volts 2,300 Fan 15 amp 120 volts 1,800 Washer I Dryer 30amp 220 volts 6,600 Dishwasher 9amp 120 volts 1,080 Garage Door Opener 4.5 amp 120 volts 540 Boiler Garage Outlet (dryer) 6amp 120 volts 720 Hot Tub 9.7 120 1164 Heated Floors (bathrooms) lOamp 120 1200 ~~l,"'-' <:>: 'l~ c~ f>a-J ~J. co.(t:...J 1.._ k__ ~\ pw~J lo~ pu N£c... ~cl~ tZL:J 20