HomeMy WebLinkAboutAsbestos Clearance.pdf"
Bob Regan
210-1349
5177 South Ventura Way
Centennial, CO 80015
R2 Samgle #
Xl-BL-01
X l-BL-02
X l-CLR-03
Xl-CLR-04
Xl-CLR-03
Xl-CLR-04
Xl-CLR-03
AIHA Laboratory Certification
Colorado Laboratory Cert(fzcation
R2 Analytical Job Number
Client
Client Project Number
Date/ Time Logged Jn
Analysis Due
Analysis Requested
f/mm2
flee
R2 LAB ID Volume(L) #Fields #Fibers Fiber Density
Fiber Concentration
BL-1 0 100 0
BL-2 0 100 0
I 153Cl-3 611 100 3.5 0.006
1153Cl-4 611 100 6.0 0.006
l 153C3-5 611 100 4.5 0.006
l l 53C3-6 611 100 8.0 0.006
1153C3-7 611 100 6.5 0.006
*BDL-Below Limit of Detection
#156492
#14903
RI 15306022018-1
l l 53X-l
1153DX-l
0610212018@ 1340hrs
2 Hour Rush
NIOSH 7400 A-Rules
flee & f/mm2
Detection Limit
0.003 BDL
0.005 BDL
0.004 BDL
0.006
0.005 BDL
Environmental Development and Training ACM LLC.
June 2, 2018
CAE Abatement LLC
P.O. Box 5110
Eagle, CO 81631
CC: Lionshead Services
P. 0. Box 452 Wheat Ridge, CO
80034
Phone 303-638-3778
RE: 1153Horn Silver Circle in Vail, CO. Asbestos Clearance testing conducted post abatement
of identified ACM drywall walls and ceiling areas in 4 upper and lower bathrooms within a
single full containment system. Abatement was to facilitate planned repair and renovation within
the current construction pathway.
Task 1 -Field Work:
1.0 Asbestos Clearance
Project Scope .of Work Conducted during Air Monitoring:
A. Contractor conducted abatement according to Colorado Regulation 8, EPA, and OSHA
containment work practices for clearances.
B. Completion of final inspections, for applicable ACM removal, and removal of all
materials, within the regulated areas.
Environmental Development & Training, ACM LLC (EDT) conducted a post abatement
visual investigation at the above-referenced site. The investigation was conducted to discern the
successful removal of ACM material using applicable State of Colorado Regulation 8, OSHA,
and EPA regulations.
2.0 SAMPLE COLLECTION METHODS
EDT ACM LLC used NIOSH method 7400, 40 CFR 763 AHERA and OSHA 29CFR 9010
methodology during activities to support abatement activity:
FINAL AIR SAMPLES:
Clearance air sampling was conducted according to Colorado Regulation 8. All of the
clearance samples collected within the work area were less than 0.01 F/CC, (fibers per
Cubic Centimeter. No concentrations were observed in excess of the Maximum
Allowable Asbestos Level (MAAL).
3.0 CONCLUSIONS
Based on observations during the site visit, and the laboratory analytical results, EDT LLC ACM
concludes the following:
All Enviromnental and Final work Area or Clearance Air samples collected outside
and inside the regulated work area clearance criteria indicated; fiber concentrations
less than or equal to 0.01 flee (fibers per cubic centimeter of air sampled). No fiber
concentrations were observed in excess of the Maximum Allowable Asbestos Level
(MAAL) per CDPHE.
Based on sampling and analysis results attached, no further action is recommended or required
for this phase of the project for the impacted areas. As additional abatement items are addressed
environmental and clearance air monitoring should be performed according to Colorado and
EPA Regulations.
, ...
4.0 LIMITATIONS
Limitations
Environmental Development and Training ACM LLC prepared this report, for the exclusive and
present use of CAE Abatement. This report addresses certain physical characteristics of the site
with regards to the release or presence of asbestos in limited, client determined, areas only.
These services were performed in a manner consistent with practices common in the
environmental health profession. The information and conclusions provided herein are valid only
with respect to the specific locations and analytes investigated at the time this report was
prepared. The findings, conclusions, and recommendations presented here are based on
information available at the time the site was evaluated.
In the event of any reuse or publication of any portion of this report, Environmental
Development and Training ACM LLC shall not be liable for damages arising out or such reuse
of publication. Any reuse a third party makes of this report, or any reliance on or decisions
made are the responsibility of such third party. Environmental Development and Training ACM
LLC accepts no responsibility for damages, if any, suffered by any third party as the result of
decisions made or actions taken based on this report.
:Z-ua 7. 'U/~
Kris Thomas Wilson
President
Environmental Development and Training ACM LLC
Environmental Development and Training ACM LLC
Phone 303-638-3778