HomeMy WebLinkAboutApproved Plans_29.pdfKNIGHT® XL BOILER DIMENSIONS AND SPECIFICATIONS LEfTSIOE Input Net Model Number Guide Kl II 701 Mia \\\\\\\c '\\\\\\ Knight XL II-Oiler. Natural Gas, 100,000 Btu/hr Input, M1J Pring controls Model Min Max Thermal Output AHRI Ratio Number MBH MBH Efficiency MBH MBH A B C 0 [ f G H I I K Gas Water A1r Ven! Shipping Conn. Conn Inlet Size WL (lb;) Notes: Indoor installation only. All information subject to change. Change "N" ta "L •{Qr LP gas models. STANDARD FEATURES > 94% Thermal Efficiency >Modulating Burner with 5:1 Tumdown Direct-Spark Ignition Low NOx Operation Sealed Combustion Low Gas Pressure Operation > ASME Stainless Steel Heat Exchanger ASME Certified, "H" Stamped Gasketless Heat Exchanger 160 psi Working Pressure 50 psi ASME Relief Valve Highly efficient, condensing design > Vertical & Horizontal Direct-Vent Category IV venting up to 100 teet PVC, CPVC. Polypropylene or AL29-4C Venting up to 100 Feet Factory Supplied Sidewall Vent Tennination > Smart System Control > Other Features On/Off Switch Adjustable High Limit w/ Manual Reset Automatic Reset High Limit Flow Switch Flue Temperature Sensor Low Air Pressure Switch Temperature & Pressure Gauge Adjustable Leveling legs Condensate Trap Zero Clearances to Combustible Material 10 Year limited Warranty (See Warranty) FIRING (ODES Standard Construction California Code CSDt I FM / GE Gap (KB501-KB801) SMART SYSTEM FEATURES > SMART SYSTEM Digital Operating Control Multi-Color Graphic LCD Display w/ Navigation Dial >Three Reset Temperature Inputs with curves for three set point temperature Inputs > Built In Cascading Sequencer for up to 8 Boilers Multiple Size Boiler Cascade front end loading capability with Copper Fin II lei!d Lag Efficiency Optimization > Outdoor Reset Control with Outdoor Air Sensor > Programmable System Efficiency Optimizers Night Setback DHW Night Setback Anti-Cycling Outdoor Air Reset Cuive Ramp Delay Boost Temperature & Time >Three Pump Control System Pump With Par.imetet for Continuous Operation Boiler Pump With Variable Speed Pump Control* Domestic Hot Water Pump > Domestic Hot water Prioritization DHW tank piped with priority in the boiler loop DHW tank pipl'<l as a zone In the system with the pumps controlled by the Smart System DHW Modulation Limiting Separately Adjustable SH/DHW Switching Times* > Building Management System Integration 0· 1 o voe Input to Control Modulation or Set Point 0·10 voe Input Signal from Variable Speed System Pump* 0-10 voe Modulation Rate Output 0-1 o voe Input to Enable/Disable call for heat Access to BMS Settings through Display > High Voltage Terminal Strip 120 VAC I 60 Hertz / 1 Phase Power Supply Three sets of Pump Contacts with Pump Relays > Low Voltage Terminal Strip 24 VAC Device Relay Proving Switch contacts Flow Switch Contacts Alann on Any Failure Contacts Runtime Contacts OHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts OHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 Voe BMS External Control Contact 0-1 O voe Boller Rate Output Contacts 0-10 voe Variable Speed System Pump Signal Input 0-1 o voe Signal to Control Variable Speed Boiler Pump Modbus Contacts '"". ··. >TimeOock fl > Data Logging Hours Running. Space Heating •f" Hours Running, Domestic Hot Water l Ignition Attempts Last 10 Lockouts > Other f'eltures Low Water Flow Safety Control & Indication Password Security Inlet & Outlet Temperature Readout Customizable Freeze Protection Parameters Custom Maintenance Reminder with Contractor Info •fx.c:Juslve feature, available only {rom l.Dchlnvar OPTIONAL fQUIPMENT---------------Alarm Bell Condensate Neutralization Kit Concentric Vent Kit (KB400-KB6ot) BMS Gateway to LON or BacNet High & low Gas Pressure Switches w/ Manual Reset (KB5ot·KB801) Variable Speed Boiler Circulation Pump MODBUS Communication Multi Temperature Loop Control Low Water Cutoffw/Manual Reset & Test Constant Speed Boller Circulation Pump Stainless Steel Vent Kits (KB701-KB801) Stack Frame