Loading...
HomeMy WebLinkAboutB17-0327_502xxxx_astm ecoflex thermal twin_1502901720.pdf 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. 2R-value is normalized based on the nominal foam thickness for a circular shape. Ecoflex® Thermal Twin Submittal Information Revision J: Nov. 24, 2015 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer’s Representative: Approved By: Technical Data Service Pipe: Crosslinked polyethylene (PEX-a) SDR-9 Engel-method tubing that conforms to German DIN 4726; smoothness value of 0.02 mil; NSF-certified Insulation: Multilayered, closed-cell, PEX-foam insulation with a thermal conductivity of 0.25 BTU in./sq. ft./hour/°F; vapor permeability of 0.1g/100 sq. in./day Jacket: Corrugated seamless high-density polyethylene (HDPE); UV-protected Hydrostatic Ratings: 200°F (93°C) at 80 psi (551 kPa or 5.51 bar) 180°F (82°C) at 100 psi (689 kPa or 6.89 bar) 73.4°F (23°C) at 160 psi (1102 kPa or 11.02 bar) Product Information and Application Use Uponor’s Ecoflex® Thermal Twin is a pre-insulated pipe system for buried or aboveground commercial and residential hydronic radiant heating and cooling applications. Service pipes are made from durable Engel-method crosslinked polyethylene (PEX-a) tubing, protected by multilayer PEX-foam insulation and covered by a corrugated, waterproof HDPE jacket. Use with Uponor ProPEX® fittings or WIPEX™ dezincification-resistant (DZR) brass compression fittings.1  Description Part Number Service Pipe O.D. Service Pipe I.D. Foam Thickness Insulation Value2 Bend Radius Weight (lbs./ft.) 1" Thermal Twin with 6.9" Jacket, 600-ft. coil 5026910 1.125" 0.862" 1.54" R-11.04 20" 1.30 lbs. 1¼" Thermal Twin with 6.9" Jacket, 500-ft. coil 5026913 1.375" 1.054" 1.34" R-9.06 28" 1.40 lbs. 1½" Thermal Twin with 6.9" Jacket 300-ft. coil 5026915 1.625" 1.244" 1.06" R-9.84 32" 1.55 lbs. 2" Thermal Twin with 7.9" Jacket, 300-ft. coil 5027920 2.125" 1.629" 1.06" R-7.06 40" 2.68 lbs. 2½" Thermal Twin with 7.9" Jacket, 300-ft. coil 5027925 2.625" 2.011" 0.59" R-4.75 48" 3.40 lbs. Installation Install Ecoflex Thermal Twin pre-insulated pipe in buried or aboveground hydronic radiant heating and cooling applications. Ecoflex End Caps are required on all exposed ends of Ecoflex pipes to avoid ground water contamination. For more information, refer to the Uponor Pre-insulated Pipe Systems Design and Installation Manual. Standards ASTM F876, F877 and F1960; CSA B137.5; NSF/ANSI 14, NSF/ANSI 61 Codes UPC, IPC, NSPC, NPC of Canada Listings cNSFus-rfh, cNSFus-pw, U.P. Code Related Applications Contact Information Pre-insulated Pipe Systems Radiant Heating and Cooling Systems Snow and Ice Melting Systems Permafrost Prevention Systems Turf Conditioning Systems Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 www.uponorpro.com Uponor Ltd. 2000 Argentia Road, Plaza 1, Suite 200 Mississauga, ON L5N 1W1 CANADA Phone: 888.994.7726 Fax: 800.638.9517 www.uponorpro.com