A18-0074_Approved Documents_1544484984.pdf
75 South Frontage Road Fire-Construction Permit 0West, TOWN OF VAIL A18-0074 Vail,CO 81657 Issued: 12/10/2018 TOWN OF VAIL „ Office:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 20 VAILRD(210108280001)(210108280001 ) Unit#: ParcelNumber: 21010 8280 0 01 Subdivision:SONNENALPSUBDIVISION Block:5-E Lot:1 R853191 MAP 10-09-03R901565DEC 12- Legal Description: 22-04R913263 EAS 04-25-058916350 EAS 05-19-05R929054EAS 09-09-05R200609923EAS 04- 18-06 R200702222 EAS 01-26-07 Contacts ContactType: Applicant Full Name: Clint Bartels Address: PO Box 883 303 CountyRoad 265 Rifle,CO 81650 Phone: 9706253398 ContactType: PropertyOwner Full Name: SONNENALPPROPERTIES INC Address: Phone: None Contractor Contractor Type: Alarm Company: AcmeAlarmCompany State License#: Phone: 970-625-3398 Projectlnformation ProjectName: Sonnenalp Properties 2018 ProjectDescription: Remodel Fire AlarmSystem in Unit 30 Fees Paid Account#:001-0000.31111.00 -Fire AlarmPermitFee Fee Amount: $112.50 Account#:001-0000.31123.00 Fire AlarmReviewFee Fee Amount: $288.00 TotalPaid: $400.50 Conditions Issued By:TownofV ailFireand EmergencyServices Department NOTICE:Byissuance ofthis Permittheapplicantagreesto complyto all Titlesof the Townof Vail Code and all applicableStateand Federal law.Failureto do so will void this Permitand the applicantshallforfeitall applicablefees. °11111 ' PERMIT FEE RECEIPT TOWN OF VAIL Case # A18-0074 Date Printed: 12/10/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: A18-0074 Status: Created Permit Number: Date Started: 12/10/2018 Permit Type: Fire-Construction Permit Subc ases Fire Alarm Lot Number: 1 Property: 20 VAIL RD (210108280001)(210108280001) Contacts Contact Type: Applicant Company Name: Acme Alarm Company Full Name: Clint Bartels Address: PO Box 883 303 County Road 265 Rifle,CO 81650 Email: clint@acmealarm.com Contact Type: Property Owner Full Name: SONNENALP PROPERTIES INC Address: Permit Fees Fee Information Account Amount Fire Alarm Permit Fee 001-0000.31111.00 $112.50 Fire Alarm Review Fee 001-0000.31123.00 $288.00 Payment Information Date Paid Payment Type Amount Fire Alarm Permit Fee 12/10/2018 Credit Card $112.50 Paid By: -Notes:Visa-Clint A Bartels Fire Alarm Review Fee 12/10/2018 Credit Card $288.00 Paid By: -Notes:Visa-Clint A Bartels FEE TOTAL $400.50 AMOUNT PAID $400.50 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 12/10/2018-3:41:01 PM-Generated by:do ouc h 1/1 Fire and Emergency Services 2399 N. Frontage Road W. Vail, Colorado 81657 TOWNTOWN O F VAIL 'L ' Tel: 970-479-2252 1Y Y 1 www.vailgov.com Fire& Emergency Services Fire Marshal FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: Office Use: 30 Meadow Drive 30 Project#: (Number) (Street) (Suite#) Building/Complex Name: Sonnenalp Building Permit#: Alarm Permit#: Contractor Information: Lot#: Block# Subdivision: Company: Acme Alarm Company Company Address: Po Box 883 Detailed S cope and Location of Work: City: Rifle State: CO Zip:81650 Remove and relocate initiating devices. Contact Name: Clint Bartels Remove and relocate notification devices. Contact Phone: 970-625-3398 E-Mail Clint@acmealarm.com (use additional sheet if necessary) Does a Monitored Fire Alarm Exist? Yes() No(171 I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate fire alarm sys- Does a Sprinkler System Exist? Yes(7I No(fl tern drawings and state that all the information as required is cor- rect. I agree to comply with the information and fire alarm system Work Class: drawings,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision New(L) Addition (L) Remodel F) Repair F) codes, design review approval, National Fire Code, International Retro-Fit(f) Other(fl) Building and Residential Codes and other ordinances of the Town applicable thereto. Type of Building: X ,,,,;.f.-t-5 ed- S ingle-Family r ) Duplex F) Multi-Family r ) Commercial(Pi Restaurant(f) Other(T) Contractor Signature(required) Property Information Complete Valuation for Fire Alarm Permit: Parcel#: 210108280001 Fire Alarm$: 3000 (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Tenant Name: Manrico Retail Date Received: Owner Name: Sonnenalp Hotel 2014-0916 TOWN OF VAIL ' Fire& Emergency Services Fire Department Process For Commercial& Residential Fire Alarm Systems Commercial and Residential Fire Alarm shop drawing requirements at the time of submittal must include the following: A Colorado Registered Engineer's stamp Device locations on reflected ceiling plans Reflected Ceiling Plans (RCP) Typical device wiring diagrams Battery calculations Battery calculations __ X A list of specific device model numbers X Equipment cut sheets of each type of device X The number of each type of device Information indicating the specific zones Circuit diagrams X Point to point wiring diagram X Wiring type, size and number of conductors The source of AC power circuits Fire alarm panel locations Knox Box location Information indicating monitoring method and monitoring agency This check list has been provided to ensure that our review process may be handled in a timely manner. I have read and understand the above listed submittal requirements: Project/Street Address: 30 Meadow Drive#30, Vail CO 81657 Contractor Signature: Date Signed: 12/10/18 2014-0916 Gamewell XP95-P Fe' FIRE TCORUMENTSLNTRO INS by Honeywell Description Photoelectric Smoke Sensor The Gamewell-FCI XP95-P analog addressable photoelec- tric sensor operates with the Gamewell-FCI analog addres- sable Fire Alarm Control Panels (FACPs). The photoelectric sensor digitally transmits its address and the • chamber's analog values to the FACP for analysis. The ;`• . photoelectric sensor is distinguished by the clear status LED, which flashes red briefly when the device is polled • and turns on continuously when the device is in alarm. _'— I J� Operat ion Ow- • The XP95-P photoelectric sensor constantly monitors its _ sensing chamber and its internal electronics. The results are then reported along with the unit's address through the XP95-P integral communications electronics located in the sensor head. The XP95 photoelectric sensor utilizes a patented smoke chamber and infrared smoke sensing design. The Features infrared emitter generates a burst of light every second, or in response to direct interrogation. • Compatible with the Gamewell-FCI 600 Series analog In clean air, the photo diode receives no light from the addressable control panels emitter because of the arrangement of the chamber.When • Fits 4.0"(10.16 cm)or 6.0" (15.24 cm)ultra-low-profile smoke enters the chamber,it scatters light from the emitter E-Z fit bases onto the photo diode receptor in proportion to smoke char- • Audible alarm sounder base acteristics and density.As the smoke content in the cham- • Four-wire relay base ber increases, the signal from the photo diode receptor • Address is stored in the sensor base increases. This information is processed and conditioned • Address is set by XPert addressing card by an on-board, advanced-technology ASIC and digitally • Two-color status LED transmitted to the FACP. • Infrared smoke sensing design • Continuous communications Trouble and Alarm conditions of the XP95 sensors are • Optional remote LED actually determined at the control panel. The status infor- mation of each sensor is analyzed for off-normal conditions by the FACP. If the sensor reports a condition that matches its programmed trouble signature,the FACP will detect that the sensor is in trouble and will follow its programmed response sequence. If the status reported matches the alarm signature, the FACP will follow the programmed An ISO 9000-2000 Company alarm response for the specific device in alarm. When a SIGNALING sensor is in alarm,the integral LED in the sensor's housing will light continuously. ® MEA LISTED Approved S1195 APPROVED 149-99-E GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are f or informationonly,are not intended forinstallation purposes,and are subject to change without notice.No responsibilityis assumed byGamewell-FCI fortheir use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2054 Rev.a1 page 1 of 2 Operation(Continued) Ordering Information The XP95-P photoelectric device is connected to a two- Model Description wire SLC carrying both data and a 17 to 28 VDC supply XP95-P Photoelectric sensor,analog voltage, and is insensitive to loop connection polarity. A addressable(55000-650) remote LED indicator may be connected. The device is XP95-B4 4.0" (10.16 cm)mounting base with compatible with point-or group-addressable relay and XPertaddressing card(45681-2101) sounder bases. XP95-B6R4 6.0" (15.24 cm)relay base (four-wire)with XPertaddressing card Engineer's Specifications XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible alarm The contractor shall furnish and install, where indicated on sounder in the base the plans, photoelectric smoke sensors with one of the 71112 Additional blank XPert addressing cards several addressable mounting base options available.The 30203 Remote LED(24 V)on single gang combination sensor head and twist-lock mounting base plate shall be UL Listed and UL Listed as compatible with the Gamewell-FCI 600 Series analog addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The photo- electric smoke sensor shall be the Gamewell-FCI model XP95-P. Specifications St andbyCurrent: 340 pA Alarm LED Current: 0.00434 A RemoteAlarm Output: 0.004 A @ 5 VDC Temperature Range: 32°F to 140°F (0° C to 60° C) RelativeHumidity: (non-condensing)0%to 95% Recommended Spacing: Meets the 30 ft.(9.1 m)spacing guidelines in NFPA72 Chapter 2. However, this spacing is based on ideal conditions and is to be used as a layout guide only.Appropriate installation-specific engineering is required. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2054 Rev.a1 page 2 of 2 www.gamewell-fci.com �Gamewell Series 95 Bases Fe' FIRE TRUMENTS CONTROL INS by Honeywell Description Analog Addressable Sensors The Gamewell-FCI XP-95 Series bases provide superior flexibility for the installation of the Gamewell-FCI, XP95 family of addressable detectors. Whether the project requires a 4.0" (10.16 cm), relay or sounder base,the XP95 *y family has a base to meet building aesthetics,constraints, 11‘ retrofit limitations or functional needs. The device address L • is held in the base, ensuring that the device address will ° f not be changed no matter how often a detector is replaced, •_ and verifying a consistent match between device type and 4L4 device address. Each XP95 analog addressable head is compatible with a wide variety of XP-95 bases, ranging from one-piece low- Series 95 profile units to four-wire relay and sounder bases that can be controlled individually or as a group.The XP95 Series of Features detector bases has been designed to enable sensors to be plugged-in with minimum force and to have a "one-way- only"fit. Relay and sounder bases can be addressed and • Compatible with all of the Gamewell-FCI 600 Series controlled individually or by a group in response to the analog addressable detectors sensor alarms. • Base options include: — 4.0"(10.16 cm)or 6.0" (15.24 cm)ultra-low-profile Programming bases feature"one-way"fit with low insertion force — 6.0"(15.24 cm)relay base(4 wire) The only programming required at the Series 95 sensors is — Audible alarm sounder bases controlled individually address setting, via the patented XPert addressing card. or by group • The card is inserted into the sensor base.When the sensor Device address is stored in the sensor base • head is inserted into the base,the address is automatically Address is set by patented XPertaddressing card • relayed to the sensor. Changing the sensor does not Compatible with all Gamewell-FCI XP95 protocol detection devices require additional programming since the address remains on the XPert Card located in the base. All other sensor- specific programming is accomplished at the Fire Alarm Control Panel (FACP). The XPert addressing card ensures that only the correct device types can be installed in given locations after cleaning or other maintenance operations. Installation The complete range of Series 95 addressable mounting An ISO 9000-2000 Company bases will accept any of the Series 95 sensors.The bases SIGNALING have a wide interior diameter for ease of access to wires 0 and terminals.The design of the base is such that the LISTED S1195 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are f or informationonly,are not intended forinstallation purposes,and are subject to change without notice.No responsibilityis assumed byGamewell-FCI fortheir use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2048 Rev.a 1 page 1 of 2 Installation(Continued) Specifications (Continued) sensor will fit in only one way, and a simple clockwise motion (without force)is required to plug-in the sensor.The Relay Base mounting base will have provisions for the insertion of the Model:XP95-B6R4 XPert addressing card as a means for programming and Alarm Current: 0.0036A maintaining the sensor's address. StandbyCurrent: 2 pA. Relay Rating: 0.04 A @ 125 VAC resistive The XP95-B4 base 4.0" (10.16 cm) will mount directly to a loading. 3.5" (8.89 cm) octagonal box (Raco 110 or equal) or a 4" Sounder Level: N/A (10.16 cm) octagonal box (Raco 125 or equal) with a round Capt iveTerminals: Yes cover/plaster ring(Raco 727 or equal). The other Series 95 bases 6.0" (15.24 cm) will mount directly to a 3.5"(8.89 cm) Sounder Base octagonal box (Raco 110 or equal); to a 4.0" (10.16 cm) Model:XP95-B65NDR octagonal box (Raco 125 or equal); or to a 4.0" (10.16 cm) Alarm Current: 0.030A square backbox(Raco 190 or equal). StandbyCurrent: 2 pA. Relay Rating: N/A Engineer's Specifications Sounder Level: 85 dB @ 10 ft.(3.048m) Capt iveTerminals: Yes The contractor shall furnish and install, as indicated on the plans, either dual-chamber ionization (Gamewell-FCI Ordering Information model XP95-I) or photoelectric (Gamewell-FCI model XP95-P)smoke sensors, analog addressable multisensor Model Description (XP95-M) or electronic thermal sensor (Gamewell-FCI XP95-B4 4.0" (10.16 cm)mounting base with model XP95-T)with one of the several addressable mount XPert addressing card (four- ingbase available options. The combination sensor head XP95-B6R4 6.0" (15.24 cm)relay base p wire)with XPert addressing card and twist-lock mounting base shall be UL Listed and UL XP95-B6EZ 6.0" (15.24 cm)ultra-low-profile EZ- Listed as compatible with the Gamewell-FCI 600 Series fit mounting base with XPert analog addressable fire alarm control panels. The base addressing card shall permit free interchange of sensor heads without XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible requiring any additional wiring or additional programming alarm sounder in the base of the head or base. (MB-SDR-XP95) 30203 Remote LED(24 VDC) 71112 Additional Bbank XPert Specifications addressing cards 4" Base Model: XP95-B4 Alarm Current: N/A StandbyCurrent: N/A Relay Rating: N/A Sounder Level: N/A Capt iveTerminals: Yes 6" Base Model: XP95-B6EZ Alarm Current: N/A StandbyCurrent: N/A Relay Rating: N/A Sounder Level: N/A Capt iveTerminals: Yes GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2048 Rev.a1 page 2 of 2 www.gamewell-fci.com I � Gamewell MS95-L Series Fe' FIRETRUMENTS CONTROL INS by Honeywell Addressable XP95 Description Manual Pull Stations The Gamewell-FCI MS95-L Series is a state-of-the-art,sin- gle- ., or dual-action XP95 pull station that includes an XP95 F R — addressable interface for any Gamewell-FCI 600 Series Fire Alarm Control Panel (FACP). Because the MS95-L I PUSH IN I Series is addressable, the FACP can display the exact 1.i PULL DOWN* location of the activated manual station.This display leads fire personnel quickly to the location of the alarm. Operation Gamewell Pushing in, then pulling down on the handle causes it to a latch in the down/activated position. Once latched, the word"ACTIVATED" (appears in bright yellow)at the top of MS95-L the handle, while a portion of the handle protrudesfromthe Features bottom of the station.To reset the station,simply unlock the • station with the key and pull the door open. This action Meets UL Standard 38,for manually actuated resets the handle; closing the door automatically resets the signaling boxes • switch.Each manual station,on command from the control Maintenance personnel can open the station without panel, sends data to the panel representingthe state of the causing an alarm condition •manual switch.The DIP switch is used to set addresses. Built in bicolor LED,which is visible through the handle of the station,flashes in normal operation and Construction latches steady red when in alarm • Handle latches in down position and the word Shell, door,and handle are molded of durable LEXAN1 (or "Activated"appears to clearly indicate the station has polycarbonate equivalent)with a textured finish. been operated • Captive screwterminals wire-ready for easy connec- Installation tion to SLC loop (accepts up to 12 AWG/3.25mm2 wire) The MS95-L Series will mount semi-flush into a single- • Semi-flush, mounts to a standard single gang (2.125" gang, double-gang, or standard 4"(10.16 cm)square electri- [5.3975]minimum depth), double gang, or 4"(10.16 cm) cal outlet box, or will surface mount to the Model SB-10 square electrical box surface backbox. If the MS95-L Series is being semi-flush • Smooth dual-action design with key reset mounted, then the optional trim ring(BG-TR)may be used. • Within ADA 5 lb. pull force The BG-TR is usually needed for semi-flush mounting with • Highly visible,attractive shape and textured finish 4" (10.16 cm) or double-gang boxes (not with single-gang • NYC backplateprovided for manual pull station boxes). • Braille text imprinted on the station handle • Optional trim ring(BG-TR) Engineer'sSpecifications • Up to 126 stations per XP95 loop Manual Fire Alarm Stations shall be non-coded, with a key- An ISO 9000-2000 Company SIGNALING operated reset lock so that they may be tested,and are 0 Lexan®is a registeredtrademark of GE Plastics,a subsidiary of General ElectricCompany. LISTED GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications areforinformationonly,arenot intended forinstallation purposes,and are subject to change without notice.No responsibilityis assumed byGamewell-FCI fortheir use. ©2008 Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2487 Rev.A2 page 1 of 2 En gin eer'sSpecification s(Con tin ued) Specifications designed so that after actual Emergency Operation,a key Normal Operatin g can be used to restore it to"Normal." Voltage: 24 VDC Maximum SLC An operated station shall automatically condition itself so Circuit Voltage: 28.0 VDC as to be visually detected as activated. Manual stations Maximum SLC shall be constructed of red-colored LEXAN (or polycar Circuit Current: 170 mA bonate equivalent) with clearly visible operating instruc- tions provided on the cover.The word FIRE shall appear Alarm Current: 0.0015 A on the front of the stations in white letters,1.00 inches Orderinginformation (25.4 mm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" Model Description (10.16 cm)square electrical box,and shall be installed within MS95-SL XP-95 pull station,single with key the limits defined by the Americans with Disabilities Act MS95-DL XP-95 pull station,dual with key (ADA)or per national/local requirements.Manual Stations SB-I/O Surface box shall be Underwriters' Laboratories Listed. BG-TR Optional trim ring NY-PLATE NYC backplatefor manual pull station Manual stations shall connect with two wires to one of the control panel SLC loops.The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the "Normal" condition,and remain steadily illuminated when in alarm. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). F1RIE 11PPUULSLIIDOWINI I a Figure 1 NY-Plate GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2487 Rev.A2 page 2 of 2 www.gamewell-fci.com SYSTEM ORE- SENSOR' Indoor Selectable- `s Output Speaker .. Strobes and Dual • .:... : Voltage Evacuation ""�• �:� •••• Speakers for Ceiling Applications SpectrAlerl°Advance selectable-output speaker strobes an ddual-voltage evacuation speakers canreduce ground SPECTRIert faults an denable faster installation. fa v .o► iN c E Features The SpectrAlert Advance Series of speakersand speaker • Plug-in design and protectivecover reduce ground faults strobes reduce costly ground faults using a p lug-in design and universal mounting plate that allow the installer to pre-wiremounting • Universal mounting plate with an onboard shorting spring tests plates,dress the wires,and confirm wiring continuity beforeplugging wiring continuity beforeinstallation in the speakers.ln addition,a protectiveplastic cover prevents • No extension ring required nicked wires by covering exposed speakercomponents. • Field selectable candela settings: Standard: 15, 15/75, 30,75,95, 110, 115 These devices also enable faster installations by providing instant High: 135, 150, 177, 185 feedbackto ensure that wiring is p rop erlyconnected,rotary switches to select voltage and powersettings,and 11 field-selectable candela • Automatic selection of 12-or 24-volt operationat 15 and settings for both wall and ceiling speakerstrobes. 15/75 candela • Rotaryswitch simplifies field selection of speakervoltage(25 The low total harmonic distortion of the SP speakeroffershigh fidelity and 70.7 Vrms)and power settings(1/4,1/, 1 and 2 watts) sound output while the SPV speakeroffershigh volume sound output • SP sp eakersoffer high fidelity sound output for use in high ambient noise applications. • SPV sp eakersoffer high volume sound output SpectrAlert Advance makes installation easy • Compatible with System Sensor synchronization protocol •Attach a universal mounting plate to a 4 x 4 x 21/8 inch back box. Electrical compatibility with existing SpectrAlert products Flush mount applications do not require an extension ring. • •Connect the notification appliance circuit or speakerwiring to the • Optional tamper resistant Torx head screw included terminals on the mounting plate. • Listed for ceiling or wall mounting •Attach the speakeror speakerstrobeto the mounting plate by inserting the product tabs into the mounting plate grooves.Rotate the device into position to lock the product pins into the mounting plate terminals.The device will temporarilyhold in place with a catch until it is secured with a captured mounting screw. Agency Listings SIGNALING mit '���'��\' MEA LISTED I_, .,t APPROVED approved S4048 7320-1653:201 10-08-E SpectrAlert Advance Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 21/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall p roducts.The notificationapp liancecircuit and amp lifierwiring shall terminateat the universal mounting p late.Also, SpectrAlert Advance speaker strobes,when used with the Sync•CircuitTMModule accessory,shall be poweredfroma non-coded notification appliancecircuit outp utand shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliancecircuitoutputsshall operate betweennine and 17.5 volts;24-volt ratednotificationappliancecircuitoutputsshall operate between 17 and 33 volts.Indoor SpectrAlert Advanceproductsshall operate between32°F and 120°F from a regulated DC,or full-wave rectified, unfiltered powersupply.Speaker strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177, 185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual-voltagetransformer speaker cap ab leof op eratingat 25.0 or 70.7 nominal Vrms.It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an op eratingtemperature between32°F and 120°F.The speaker shall have powertaps and voltagethat are selected by rotary switches. Speaker Strobe combination The speaker strob eshall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be cap ab leof op eratingat 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequencyrange of 400 to 4,000 Hz.The speaker shall have p owertaps that are selected by rotary switch.The strob eshall comply with the NFPA 72 requirements for visiblesignaling ap pliances,flashing at 1 Hz over the strobe's entireop eratingvoltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 411/16 x 411/16 x 21/8-inch b ackbox.The module shall also control two Style Y (class B)circuitsor one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules togetherwill synchronize all the zones they control.The module shall not operate on a coded powersupply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Dimensions,Ceiling-Mount SPS Speaker Strobe 6.8 in Dia.x 4.7 in D(including lens and speaker) SPSV Speaker Strobe 6.8 in Dia.x 4.8 in D(including lens and speaker) SP Speaker 6.8 in Dia.x 2.8 in D SPV Speaker 6.8 in Dia.x 2.9 in D Electrical/Operating Specifications Nominal Voltage(speakers) 25 Voltsor 70.7 Volts(nominal) Maximum SupervisoryVoltage(speakers) 50 VDC Strobe Flash Rate 1 flash persecond Nominal Voltage(strobes) Regulated 12 V DC/FWRor regulated24 DC/FWR Operating Voltage Range(includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL Sync Module 9 to 17.5 V(12 V nominal)or 17 to 33 V(24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4,1/2, 1, 2 watts AVDS00701 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8 to 17.5Volts 16 to 33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant(dBA@ 10 ft.) 2W 1W 1/2W l/4 W Ceiling-MountSPC Series 86 83 80 77 Ceiling-MountSPCV Series 90 87 84 81 Ceiling-MountSPSC Series 85 82 79 76 Ceiling-MountSPSCV Series 89 86 83 80 Dimensions - 6.81" -9 7=f-1.96"= 6.81" [97i--1.84"=- ------ oo°po°O°°Oo °o o e „... ._ �'�o000'eo 000:%eo°e°e°°e°e°o°° 4111111111 , o°o°o°o°po°o°�o°000000°00000°000°0°00°o I I0000000° ° °e 00000 000°0000 I°°Oa o I' �i� °000000°o0000000eo 000°ee00000000000000s°000p00000000 ■ o°000°ooppO0000 \ I 'o°o°o°o°o°o°o°e°m°o°oeOoppO0000000 e°oo°0000000000 o1o°o1111 0000\ o0000000ae0°oopOm0000000 0000000000000000\°00000°000OeOO OsOoeo.00000/ _ —I,J II000eoe000e°a°a°o°o°o°oo°o°oO°� 00000000000c/0000 o ee 0$o0o°0000°o°o° 0000 e00000000000 0 00 Op000000000 0000p Op oppo 000 000 p°QQ�o 000®oo/ •�• °o°0000°0000 00000 °000°e°®o°o°o° _____. 0 0°oo°°p°o°oo°00000000° o°0000°o°°o°o°`000°poo°o°0000°� °\I°pp 0000 poop / s,000„0.„.0,0„, o°o 000po, °� _____o_____ Ceiling-MountSPV Speaker Ceiling-Mount SP Speaker 2.83" • 6.81" • 1.60" 1.84L- 0 000000p . oes 0000000°o°o°po°0s e i o 0 opO000°o°po°o°o: lin I00er %/i 00°0 _ o1, , 41, 00000\00000°o 'I00000 I00000 00000 00000 00000 ,I..000 0000 00000 00000•,•000000000.p0 00000;0°° E 'Ir' o OOpoo°o°o°o°ppOo 0° Ceiling-Mount SPS Speaker Strobe AVDS00701 Surface Mounting sv 0 \\- o°o°poop°uouuauu�u�amu° 0 poop°a°0000a000 0 O °°poo°0 0 p0000 p00000000 ) ' �o°o°o°oo°o°:o00000 a°o°oo000000000 ,,,___r,_____S------.' ...// If?Plitklio 00000000000°0°00000p0000 f 00000°0°0°0°0°0°00°00° 0 \00000000:0000000000000 I�� 00000000p000000000' 0°°°00°oo0ou°oo°o ® IIA f 00000000000000 m f�� r�I� °00°0°0000°0000000 fir,., / I00°0000000000°•o0 Ceiling-Mount Speaker with SPBBSCW Back Box Ordering Information for SpectrAlert°Advance Speakers and Speaker Strobes Ceiling Mount White Red Description SPCW SPCR Speaker only SPCWV SPCR V Speaker only,High dB SPSCW" SPSCR Speaker Strobe,Standardcd SPSCWH" SPSCRH Speaker Strobe,High cd SPSCWV" SPSCRV Speaker Strobe,Standardcd, High dB SPSCWVH SPSCRVH Speaker Strobe,High cd, High dB SPSCW-CLR-ALERT — Speaker Strobe, Standardcd,Clear Lens Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SPBBSCW SPBBSC Ceiling Mount Back Box Skirt TR CW TRC Ceiling Mount TrimR ing Notes: *Add-P to model number for plain housing(no"FIRE"marking on the cover)e.g.SPSCW-P $"Standard cd"refersto strobes that include 15, 15/75,30,75,95,110, and 115 candela settings."High cd"refersto strobes that include 135, 150, 177,and 185 candela settings. f" SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subjectto changewithout notice.Visitsystemsensor.com ._. ) SENSOR" Phone:800-SENSOR2•Fax:630-377-6495 forcurrent product information,includingthe latest version of this datasheet. AVDS00701.3/12 SYSTEM �$ SENSOR' Indoor Selectable- a " -= Output Strobes and ,� �- �, _iti. Horn Strobes for �' = r Ceiling Applications ','£;{ m SpectrAlert®Advance audible visible notification products _. ar erich with features guaranteed t ocutinstallation times SPECTArdiLarfilert an dmaximize profits. A N c q Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns,strobes,and horn strobesin the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIR E-p rinteddevices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operationat 15 and can meet virtually any application requirement. 15/75 candela • Field-selectable candela settings on ceiling units: 15, 15/75,30, Like the entire SpectrAlertAdvance product line, ceiling-mount strobes and horn strobes include a variety of featuresthat increase 75,95, 110, 115, 135, 150, 177, and 185 their application versatilitywhile simplifying installation.All devices • Horn rated at 88+dBA at 16 volts featureplug-in designs with minimal intrusion into the back box, • Rotaryswitch for horn tone and three volume selections making installations fast and foolp roof while virtually eliminating • Universal mounting plate for ceiling units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before Tofurther simplify installation and protectdevices from construction device installation damage,SpectrAlertAdvance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlertdevices with an onboard shorting spring,so installers can test wiring continuity beforethe device is installed. • Compatible with MDL sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING Q ® MEA 0 LISTED APPROVED approved 77125-125-1653:1653:186(ind 188(hornoorstrobes,strobes) S4011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strobes) S5512(strobes) 7135-1653:189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard4 x 4 x 11/cinch backbox,4-inch octagon b ackbox,or doub le- gang back box.Two-wire productsshall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plateshall be used for mounting ceiling and wall p roducts.The notificationap p liancecircuit wiring shall terminateat the universal mounting p late.Also,SpectrAlert Advanceproducts,whenusedwiththeSync•Circuit° Module accessory,shall be poweredfrom a non-coded notificationap p liancecircuit outp utand shall operate on a nominal 12 or 24 volts.When used with the Sync•CircuitModule, 12-volt-rated notificationap p liancecircuit outputsshall operate between9 and 17.5 volts;24-volt-rated notificationappliancecircuitoutputsshall operate betweenl7 and 33 volts. Indoor SpectrAlert Advance productsshall operate between32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered powersupply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobeshall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobeshall be wired as a primary-signaling notificationap p lianceand comply with the Americanswith Disab ilitiesAct requirements for visiblesignaling app liances,flashing at 1 Hz over the strobe's entireop eratingvoltage range.The strob elight shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Com bination The horn strobeshall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strob eshall be wired as a primary-signaling notificationap p lianceand comply with the Americanswith Disab ilitiesAct requirements for visible signaling app liances,flashing at 1 Hz over the strobe's entireop eratingvoltage range.The strobelight shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audib ilityoptionsand an op tionto switch b etweena temp oralthreep atternand a non-temporal(continuous)pattern.These optionsare set by a multiple positionswitch.On four-wire p roducts,the strobeshall be p oweredindep endentlyof the sounder.The horn on horn strobemodels shall operate on a coded or non-coded p owersupply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temp oralthree.Also,while operatingthe strobes,the module shall silence the horns on horn strobemodels overa single pairof wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also controltwo Style Y(class B)circuitsor one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded powersupply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Hum idityRange 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nom inalVoltage Regulated 12 DC/FWRor regulated24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) InputTerminal WireGauge 12 to 18 AWG Ceiling-Mount Dim ensions(including lens) 6.8"diameterx 2.5"high(173 mm diameterx 64 mm high) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.2"high(180 mm diameterx 57 mm high) Ceiling-MountTrim Ring Dim ensions(sold as a 5 pack)(TRC-HS, 6.9"diameterx 0.35"high(175 mm diameterx 9 mm high) TRCW-HS) Notes: 1. Full Wave Rectified(FWR)voltageis a non-regulated,time-varying powersourcethat is used on some powersupplyand panel outputs. 2.P,S,PC,and SC p roductswill operate at 12 V nominal only for 15 and 15/75 cd. AVDS00501 UL Current Draw Data UL Max.Strobe Current Draw(m ARMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(m ARMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(m ARMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn StrobeTones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. AVDS00501 SpectrAlert Advance Dimensions 7.1" 14-2.251 6.8" \ Dia. �I Dia. F 4(,,-::p . o Q,' . e 14t,t 2.5" o ,.p O \ i J I , ° Cy --,rrte I C Ceiling-mounthorn strobes Ceiling backbox skirt SpectrAlert Advance Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2R" 2-WireHorn Strobe,Standardcd, Red SCR Strobe,Standardcd, Red PC2RH 2-WireHorn Strobe,High cd, Red SCRH Strobe,High cd, Red PC2W"r 2-WireHorn Strobe,Standardcd,White SCW" Strobe,Standardcd,White PC2WH" 2-WireHorn Strobe,High cd,White SCWH Strobe,High cd,White PC4R 4-WireHorn Strobe,Standardcd, Red Accessories PC4RH 4-WireHorn Strobe,High cd, Red BBSC-2 Back Box Skirt,Ceiling,Red PC4W 4-WireHorn Strobe,Standardcd,White Back Box Skirt,Ceiling,White TRC-HS TrimRing,Ceiling,Red TRCW- TrimRing,Ceiling,White HS Notes: "Add"-P"to model number for plain housing(no"FIR E"markingon cover),e.g.,P2R-P. t Add"-SP"to model number for"FUEGO"markingon cover,e.g.,P2R-SF'. $"Standardcd"refers to strobes that include 15, 15/75,30,75,95,110, and 115 candela settings."High cd"refers to strobes that include 135, 150, 177,and 185 candela settings. *--Th_ SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subjectto changewithout notice.Visitsystemsensor.com )' SENSOR Phone:800-SENSOR2•Fax:630-377-6495 forcurrent product information,includingthe latest version of this datasheet. AVDS00501•3/12